Instruction Manual
Thermometer
models 00415/00416/00417/00418/00420
CONTENTS
Unpacking Instructions ........... 2
Package Contents .................. 2
Product Registration ............... 2
Features & Benefits................. 3
Setup .................................... 4
Install or Replace Batteries...... 4
Temperature Units.................. 4
Clock Setup........................... 5
Placement Guidelines ............. 6
Using the Thermometer........... 7
Troubleshooting ..................... 8
Care & Maintenance.............. 9
Specifications......................... 9
FCC Information .................... 9
Customer Support.................10
Warranty..............................10
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Features & Benefits
11
12
1
2
7
8
3
4
13
5
6
9
10
9. MAX/MIN Button
DISPLAY UNIT
1. Sensor Low Battery Indicator
2. Current Outdoor Temperature
Press to view high/low temperature
records.
10. + Button
For setup preferences.
3. Clock
Displays time in either 12 hour or 24
hour formats.
OUTDOOR SENSOR
4. Current Indoor Temperature
11. Integrated Hanger
For easy placement.
5. OF/OC Button
Press to select degrees Fahrenheit or
degrees Celsius.
12. Wireless Signal Indicator
Flashes when data is being sent
to the display unit.
6. Set Button
For setup preferences.
13. Battery Compartment Cover
7. Wireless Sensor Signal Strength
8. Display Low Battery Indicator
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUP
Install or Replace Batteries
AcuRite recommends high quality alkaline batteries for the best product
performance. Heavy duty or rechargeable batteries are not recommended.
The outdoor sensor requires lithium batteries in low temperature conditions.
Cold temperatures can cause alkaline batteries to function improperly. Use
lithium batteries in the outdoor sensor for temperatures below -4ºF / -20ºC.
Outdoor Sensor
1. Slide off the battery compartment
cover.
2. Insert 2 x AA batteries into the
battery compartment, as shown.
Follow the polarity (+/-) diagram in
the battery compartment.
3. Replace the battery cover.
Display Unit
1. Slide off the battery compartment
cover.
2. Insert 2 x AA batteries into the
battery compartment, as shown.
Follow the polarity (+/-) diagram in
the battery compartment.
3. Replace the battery cover.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire,
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge
non-rechargeable batteries. DO NOT short-circuit the supply terminals.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Clock Setup
Press and hold the “SET” button for 3 seconds to enter SET MODE. Once in set
mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) preference item, press the “+” button
(press and HOLD to fast adjust).
To save your adjustments, press and release the “SET” button again to adjust
the next preference.
The preference set order is as follows:
CLOCK HOUR MODE (12 hour or 24 hour)
CLOCK HOUR
CLOCK MINUTE
You will automatically exit SET MODE if no buttons are pressed for 30
seconds. Enter basic setup mode at any time by pressing and holding the “SET”
button for 3 seconds.
Select Degrees Fahrenheit or Celsius
To select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units,
p r e s s t h e “ º F / º C ” b u t t o n l o c a t e d o n t h e f r o n t o f t h e d i s p l a y u n i t .
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display unit and outdoor sensor are critical to the
accuracy and performance of this product.
Display Unit Placement
Place the display unit in a dry area free of dirt and dust.
Display unit stands upright for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensor must be placed outside to observe outdoor conditions.
Sensor is water resistant and is designed for general outdoor
use, however, to extend its life place the sensor in an area
protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or
by using string (not included) to hang it from a suitable location,
like a well covered tree branch. The best location is 4 to 8 feet
above the ground with permanent shade and plenty of fresh air
to circulate around the sensor.
Important Placement Guidelines
• To ensure accurate temperature measurement, place units out of direct
sunlight and away from any heat sources or vents.
• Display unit and outdoor sensor must be within 165 ft (50 m) of each other.
• To maximize wireless range, place units away from large metallic items, thick
walls, metal surfaces, or other objects that may limit wireless communication.
• To prevent wireless interference, place both units at least 3 ft (.9 m) away
from electronic devices (TV, computer, microwave, radio, etc.).
(165 feet maximum)
(50 meters)
Setup is Complete
The sensor will now synchronize with the display unit. It may take a few
minutes for synchronization to complete. Please refer to the troubleshooting
section of this manual if anything appears to be functioning improperly.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Using the Thermometer
High/Low Records
Press the “MAX/MIN” button to view minimum and maximum outdoor and in-
door temperature records. The temperature records are automatically cleared
daily at midnight.
To view the MAXIMUM recorded outdoor and indoor temperature readings,
press and release the “MAX/MIN” button. The “MAX” icon appears on the
display.
To manually clear the MAXIMUM recorded values, press and hold the “MAX/
MIN” button while in the MAX view mode. Dashes display to confirm you have
cleared the MAXIMUM records.
To view the MINIMUM recorded outdoor and indoor temperature readings,
press and release the “MAX/MIN” button until the “MIN” icon appears on the
display.
To manually clear the MAXIMUM recorded values, press and hold the “MAX/
MIN” button while in the MIN view mode. Dashes display to confirm you have
cleared the MINIMUM records.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
If the wireless signal indicator shows no bars:
• Relocate the display unit and/or the outdoor sensor.
The units must be within 165 ft (50 m) of each other.
•
Make sure both units are placed at least 3 feet (.9 m)
away from electronics that may interfere with the
wireless communication (such as TVs, microwaves,
computers, etc).
No outdoor sensor
reception
no bars
• Use standard alkaline batteries (or lithium batteries in
sensor when temperature is below -4ºF/-20ºC). Do not
use heavy duty or rechargeable batteries. NOTE: It
may take up to 20 minutes for display unit and sensor
to synchronize after batteries are replaced.
Flashing of the outdoor temperature is generally an
indication of wireless interference.
1. Bring both the sensor and display unit indoors and
remove at least one battery from each.
2. Reinstall the battery in the outdoor sensor.
3. Reinstall the battery in the display unit.
Outdoor
temperature
is flashing or
showing dashes
4. Let the units sit within a couple feet of each other
for about 20 minutes to gain a strong connection.
• Make sure both the display unit and sensor are
placed out of direct sunlight and away from any heat
sources or vents (see page 6).
Inaccurate
temperature
Display screen
not working
• Check that the batteries are installed correctly.
Batteries may need to be replaced.
If your AcuRite product does not operate properly after trying
(877) 221-1252 for assistance.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Care & Maintenance
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Specifications
Outdoor: -40ºF to 158ºF; -40ºC to 70ºC
Indoor: 32ºF to 122ºF; 0ºC to 50ºC
165 ft / 50 m depending on home construction materials
433 MHz
TEMPERATURE RANGE
WIRELESS RANGE
WIRELESS FREQUENCY
POWER
Display: 2 x AA alkaline batteries
Sensor: 2 x AA alkaline or lithium batteries
30 second updates
DATA REPORTING
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Such modifications could void the user authority to operate the equipment.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer Support
AcuRite customer support is committed to providing you with best-in-
class service. For assistance, please have the model number of this
product available and contact us in any of the following ways:
(877) 221-1252
24/7 support at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
Register a Product
►
www.AcuRite.com
Limited One Year Warranty
warranty will not be breached, and Chaney will give no credit
for products it manufactures which have received normal wear
and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired
or altered by others than authorized representatives of Chaney.
At AcuRite, we proudly uphold our commitment
to quality technology. Chaney Instrument Co.
warrants that all products it manufactures to
be of good material and workmanship, and to
be free of defects when properly installed and
operated for a period of one year from the date
of purchase.
The above-described warranty is expressly in lieu of all other
warranties, express or implied, and all other warranties are
hereby expressly disclaimed, including without limitation the
implied warranty of merchantability and the implied warranty
of fitness for a particular purpose. Chaney expressly disclaims
all liability for special, consequential or incidental damages,
whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation
or exclusion may not apply to you. Chaney further disclaims all
liability from personal injury relating to its products to the extent
permitted by law. By acceptance of any of Chaney’s products,
the purchaser assumes all liability for the consequences arising
from their use or misuse. No person, firm or corporation is
authorized to assume for Chaney any other liability in connection
with the sale of its products. Furthermore, no person, firm or
corporation is authorized to modify or waive the terms of this
paragraph, and the preceding paragraph, unless done in writing
and signed by a duly authorized agent of Chaney. This warranty
gives you specific legal rights, and you may also have other
rights which vary from state to state.
We recommend that you visit us at
your product. However, product registration
does not eliminate the need to retain your
original proof of purchase in order to obtain
warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures
to be of good material and workmanship, and to be free of
defects when properly installed and operated for a period of
one year from the date of purchase. Remedy for breach of this
warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is
proven to breach the warranty contained herein within ONE
YEAR from date of sale will, upon examination by Chaney,
and at its sole option, be repaired or replaced by Chaney.
Transportation costs and charges for returned goods shall
be paid for by the purchaser. Chaney hereby disclaims all
responsibility for such transportation costs and charges. This
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
10
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Weather
Stations
Temperature
& Humidity
Weather
Alert Radio
Kitchen
Thermometers
& Timers
Clocks
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the
Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights
are the property of their respective owners. AcuRite uses patented technology.
Printed in China
00420 INST 041114
Download from Www.Somanuals.com. All Manuals Search And Download.
|