Bosch Appliances Network Router DVRXEAP01 User Manual

ATM/POS Bridge  
DVRXEAP01  
en Installation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Table of Contents | en  
3
Table of Contents  
1
Safety  
5
1.1  
FCC & ICES compliance  
7
2
Description  
9
9
9
2.1  
2.2  
Parts List  
Supported Protocols  
3
System Overview  
10  
4
Installation  
11  
11  
12  
14  
4.1  
4.2  
4.3  
Mounting the Bridge  
Making Connections to the Bridge  
COM Connector Detail  
5
Configuration  
15  
15  
15  
16  
18  
18  
19  
21  
23  
5.1  
Configuring the Bridge for a Network Connection  
Using the Bridge Detector Utility  
Using the Direct Connection  
Configuring Operation via a Network  
System Menu  
5.1.1  
5.1.2  
5.2  
5.2.1  
5.2.2  
5.2.3  
5.2.4  
Network Setup  
Terminal  
COM Port  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
en | Table of Contents  
ATM/POS Bridge  
6
Configuration Using HyperTerminal  
24  
24  
24  
26  
26  
28  
29  
31  
31  
32  
6.1  
Connecting the Bridge  
Initiating a HyperTerminal Session  
Configuring Bridge Operation via HyperTerminal  
Network Setup  
6.2  
6.3  
6.3.1  
6.3.2  
6.3.3  
6.3.4  
6.3.5  
6.3.6  
Communication Channels  
Terminal Setup  
Simulation Mode  
Recording Language  
Service Menu  
7
8
A
Troubleshooting  
33  
34  
36  
Technical Data  
Updating Bridge Firmware  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Safety | en  
5
1
Safety  
Type numbers:  
DANGER!  
High risk: This symbol indicates an imminently hazardous  
situation such as “Dangerous Voltage” inside the product.  
If not avoided, this will result in an electrical shock, serious  
bodily injury, or death.  
WARNING!  
Medium risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in minor or moderate bodily  
injury.  
CAUTION!  
Low risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in property damage or risk of  
damage to the unit.  
Read, follow, and retain all of the following safety instructions.  
Heed all warnings on the unit and in the operating instructions  
before operation.  
1. Clean only with a dry cloth. Do not use liquid cleaners or  
aerosol cleaners.  
2. Do not install unit near any heat sources such as radiators,  
heaters, stoves, or other equipment (including amplifiers)  
that produce heat.  
3. Do not block any ventilation openings.  
4. Do not use the unit near water or expose to rain or  
moisture. Never spill liquid of any kind on the unit.  
5. Unplug the unit during lightning storms or when unused for  
long periods. Take precautions to protect the unit from  
power and lightning surges.  
6. Adjust only those controls specified in the operating  
instructions.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
en | Safety  
ATM/POS Bridge  
7. Do not overload outlets and extension cords, as this can  
cause fire or electrical shock.  
8. Protect the plug and power cord from foot traffic or  
pinching, at electrical outlets, and at its exit from the unit.  
9. Operate the unit only from the type of power source  
indicated on the label.  
10. Unless qualified, do not attempt to service a damaged unit  
yourself. Refer all servicing to qualified service personnel.  
11. Use only replacement parts specified by the manufacturer.  
12. Install in accordance with the manufacturer's instructions  
in accordance with applicable local codes.  
13. Use only attachments/accessories specified by the  
manufacturer. Equipment change or modification could  
void the user's guarantee or authorization agreement.  
You can view and print the full version of this Installation  
Manual with Adobe Acrobat Reader, both provided on the  
enclosed CD-ROM. This user guide is the intellectual property  
of Bosch Security Systems; protected by copyright. Contact:  
CAUTION!  
This unit has a battery inside the enclosure. Risk of explosion if  
battery is replaced by incorrect type. Replace only with the  
same or equivalent type recommended by the manufacturer.  
Refer all servicing to qualified service personnel.  
NOTICE!  
Batteries must not be disposed of in household waste. Dispose  
of batteries only at suitable collection points and, in the case of  
lithium batteries, mask the poles. For further information refer  
NOTICE!  
Bosch has a strong commitment towards the environment. This  
unit has been designed to respect the environment as much as  
possible.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Safety | en  
7
1.1  
FCC & ICES compliance  
FCC & ICES Information  
(U.S.A. and Canadian Models Only)  
This equipment has been tested and found to comply with the  
limits for a Class B digital device, pursuant to part 15 of the  
FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential  
installation. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference  
to radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following  
measures:  
reorient or relocate the receiving antenna;  
increase the separation between the equipment and  
receiver;  
connect the equipment into an outlet on a circuit different  
from that to which the receiver is connected;  
consult the dealer or an experienced radio/TV technician  
for help.  
Intentional or unintentional modifications, not expressly  
approved by the party responsible for compliance, shall not be  
made. Any such modifications could void the user's authority to  
operate the equipment. If necessary, the user should consult  
the dealer or an experienced radio/television technician for  
corrective action.  
The user may find the following booklet, prepared by the  
Federal Communications Commission, helpful: How to Identify  
and Resolve Radio-TV Interference Problems. This booklet is  
available from the U.S. Government Printing Office,  
Washington, DC 20402, Stock No. 004-000-00345-4.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
en | Safety  
ATM/POS Bridge  
Informations FCC et ICES  
(modèles utilisés aux États-Unis et au Canada uniquement)  
Suite à différents tests, cet appareil s'est révélé conforme aux  
exigences imposées aux appareils numériques de classe B, en  
vertu de la section 15 du règlement de la Commission fédérale  
des communications des États-Unis (FCC), et en vertu de la  
norme ICES-003 d'Industrie Canada. Ces exigences visent à  
fournir une protection raisonnable contre les interférences  
nuisibles lorsque l'appareil est utilisé dans le cadre d'une  
installation résidentielle. Cet appareil génère, utilise et émet  
de l'énergie de radiofréquences et peut, en cas d'installation ou  
d'utilisation non conforme aux instructions, engendrer des  
interférences nuisibles au niveau des radiocommunications.  
Toutefois, rien ne garantit l'absence d'interférences dans une  
installation particulière. Il est possible de déterminer la  
production d'interférences en mettant l'appareil  
successivement hors et sous tension, tout en contrôlant la  
réception radio ou télévision. L'utilisateur peut parvenir à  
éliminer les interférences éventuelles en prenant une ou  
plusieurs des mesures suivantes:  
Modifier l'orientation ou l'emplacement de l'antenne  
réceptrice;  
Éloigner l'appareil du récepteur;  
Brancher l'appareil sur une prise située sur un circuit  
différent de celui du récepteur;  
Consulter le revendeur ou un technicien qualifié en radio/  
télévision pour obtenir de l'aide.  
Toute modification apportée au produit, non expressément  
approuvée par la partie responsable de l'appareil, est  
strictement interdite. Une telle modification est susceptible  
d'entraîner la révocation du droit d'utilisation de l'appareil.  
La brochure suivante, publiée par la Commission fédérale des  
communications (FCC), peut s'avérer utile : How to Identify and  
Resolve Radio-TV Interference Problems (Comment identifier et  
résoudre les problèmes d’interférences de radio et de télévision).  
Cette brochure est disponible auprès du U.S. Government  
Printing Office, Washington, DC 20402, États-Unis, sous la  
référence n° 004-000-00345-4.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Description | en  
9
2
Description  
The ATM/POS Bridge provides an interface between a digital  
recorder and either Automatic Teller Machines (ATM) or Point-  
of-Sale (POS) equipment such as cash registers. Both single-  
and multi-drop ATM networks are supported. This allows  
financial transaction data to be recorded and linked to specific  
camera images.  
The bridge supports up to four (4) serial connections to directly  
connect devices to each ATM/POS bridge. The bridge also  
supports connection to a TCP/IP network. In this configuration,  
the bridge can transmit transactional data from any terminal on  
the same network to a digital video recorder.  
2.1  
Parts List  
The ATM/POS Bridge package contains the following  
components:  
1 ATM/POS Bridge unit  
1 External DC power supply  
1 Mounting kit  
2 Connection cables  
1 Console cable  
CD-ROM with software utilities  
Installation manual  
2.2  
Supported Protocols  
The ATM/POS Bridge is designed to operate with many  
different terminals. If you have any questions regarding the  
suitability of the firmware for your terminal or any other  
questions, contact your Bosch Security Systems, Inc.  
representative.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 en | System Overview  
ATM/POS Bridge  
3
System Overview  
The following illustration shows an example of how a bridge is  
used in a network of digital video recorders and POS terminals.  
Figure 3.1 POS terminal network  
1
2
3
POS Terminal  
ATM/POS Bridge  
Recording Device  
4
5
TCP/IP Network  
Printer  
The following illustration shows an example of how a bridge is  
used in a network of digital video recorders and ATM terminals.  
Figure 3.2 ATM terminal network  
1
2
3
ATM Terminal  
ATM/POS Bridge  
Recording Device  
4
5
TCP/IP Network  
ATM Modem  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Installation | en 11  
4
Installation  
This section details the physical installation of the ATM/POS  
Bridge.  
4.1  
Mounting the Bridge  
Determine a location where all incoming connections can reach  
the ATM/POS Bridge.  
Using the screws provided, attach the two mounting brackets  
to the sides of the bridge. Secure the brackets to a solid fixture.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 en | Installation  
ATM/POS Bridge  
4.2  
Making Connections to the Bridge  
Use the following illustration to make the appropriate  
connections to the ATM/POS Bridge:  
Figure 4.1 ATM/POS Bridge connectors  
1
2
3
4
5
6
7
Ethernet RJ45 connector  
COM 3 RS-232 connector (console port)  
DC power input connector  
Activity indicator  
COM 4 RS485 connector  
COM 2 RS232 connector  
COM 1 RS232 connector  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Installation | en 13  
1. Connect the supplied DC power adapter unit to the DC  
power input connector of the bridge.  
2. Connect the RJ45 connector of the bridge via a straight  
Ethernet CAT5 network cable to a network switch or hub  
that supports 10BaseT.  
3. Connect your terminal to COM ports 1, 2, 3, or 4 of the  
bridge using the supplied cable. Refer to Section 4.3 COM  
Connector Detail, page 14 for pin-out details.  
Note: Choose COM port 4 on the bridge if your connection  
protocol is RS485.  
4. Use the supplied splitter cable if the terminal device is also  
connected to a printer.  
a. Remove the existing cable that connects the terminal  
to a printer.  
b. Using the splitter cable, connect one male connector  
to the terminal.  
c. Connect the other male connector to the printer.  
d. Connect the cable from the bridge to the open  
connector on the splitter cable.  
5. Refer to Section 5 Configuration, page 15 to configure the  
communication and terminal settings.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14 en | Installation  
ATM/POS Bridge  
4.3  
COM Connector Detail  
The four COM connectors on the bridge are all 9-pin SubD-type  
male connectors.  
1
5
6
9
Figure 4.2 COM connector detail  
Pin  
COM 1  
RS232  
COM 2  
RS232  
COM 3  
(console)  
RS232  
COM 4  
RS485  
1
2
3
4
5
6
7
8
9
Rx  
Tx  
Rx  
Tx  
Rx  
Tx  
D2+  
D2-  
GND  
GND  
GND  
GND  
RxC  
TxC  
RxC  
TxC  
INIT  
Note: The console cable has pin 9 connected to pin 5 (GND).  
When pin 9 of COM 3 (console) is at GND level on power-up,  
the bridge enters firmware download mode.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration | en 15  
5
Configuration  
You must configure the ATM/POS Bridge network settings to  
ensure proper communication on an existing TCP/IP network.  
This section provides configuration details using the Web-based  
interface.  
To configure the bridge using a HyperTerminal session, refer to  
Section 6 Configuration Using HyperTerminal, page 24.  
For instructions to update the ATM/POS Bridge firmware, refer  
to Section A Updating Bridge Firmware, page 36.  
5.1  
Configuring the Bridge for a Network  
Connection  
The ATM/POS Bridge allows two methods to configure network  
settings:  
Use the Bridge Detector utility (supplied on the CD-ROM)  
to set the network settings (the Device Detection  
parameter must be set to Enable, refer to  
Section 5.2.2 Network Setup, page 19).  
or  
Use a cross-over Ethernet cable to allow an APIPA-enabled  
workstation to connect to the bridge. The default network  
setting for the bridge falls within the APIPA address  
ranges.  
5.1.1  
Using the Bridge Detector Utility  
NOTICE!  
Contact your local network administrator for a valid IP Address,  
Subnet Mask, and a Gateway IP Address.  
1. Connect the supplied DC power adapter unit to the DC  
power input connector of the bridge.  
2. Connect the RJ45 connector of the bridge via a straight  
Ethernet CAT5 network cable to a network switch or hub  
that supports 10BaseT.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16 en | Configuration  
ATM/POS Bridge  
3. From a PC connected to the same network, launch the  
BridgeDetector.exe application, located on the CD.  
The PC opens the Bridge Detector window that displays  
the MAC Address and the default IP Address, Subnet Mask,  
and Gateway for the bridge.  
4. To change the network settings for the bridge, first select a  
bridge. Then, type a valid IP Address, Subnet Mask, and  
Gateway in the input boxes on the right side of the Bridge  
Detector window.  
Note: The MAC Address cannot be changed.  
5. Click the Update button to accept the network settings  
and to apply these settings to the bridge.  
5.1.2  
Using the Direct Connection  
The ATM/POS Bridge allows network configuration via an  
APIPA-enabled computer.  
NOTICE!  
Contact your local network administrator for a valid IP Address,  
Subnet Mask, and a Gateway IP Address.  
1. Ensure that the PC is configured to use DHCP.  
2. Connect the supplied DC power adapter unit to the DC  
power input connector of the bridge.  
3. Connect the bridge directly to a PC using an RJ45 cross-  
over Ethernet CAT5 network cable.  
4. Reboot the PC after you connect to the bridge with the  
cross-over Ethernet cable.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration | en 17  
5. Launch Internet Explorer and navigate to the default bridge  
IP Address: 169.254.1.1  
Internet Explorer displays the ATM/POS Bridge interface.  
6. Click the Network Setup link in the navigation pane.  
7. Type an optional name for the bridge in the Bridge Name  
input box. This name facilitates recognition of the bridge  
on the network.  
8. To change the network settings for the bridge, type a valid  
IP Address, Subnet Mask, and Gateway in the appropriate  
input boxes.  
Note: The MAC Address cannot be changed.  
9. Click the Save button to accept the network settings and  
to apply these settings to the bridge.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18 en | Configuration  
ATM/POS Bridge  
5.2  
Configuring Operation via a Network  
After the bridge is properly configured for network access, you  
can configure the COM and Terminal settings via Internet  
Explorer.  
To access the bridge configuration page:  
1. Launch Internet Explorer and navigate to the IP address for  
the bridge.  
Internet Explorer displays the ATM/POS Bridge interface.  
2. Use the menu in the left pane to navigate to the various  
configuration pages.  
3. Refer to the following sections for details about each  
configuration page.  
4. Click Save on each page to accept the changes.  
5.2.1  
System Menu  
The System Menu contains settings for bridge operation.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration | en 19  
Simulation Mode: Select the type of device to test the  
connection between the bridge and the digital recorder.  
Select this mode to send sample data from the bridge to  
the digital recorder.  
Recording Language: Select the language that is set on the  
digital recorder to ensure that characters display correctly.  
Log Level: Ensure that the Log Level setting is None. This  
setting is used for diagnostic purposes only.  
Log Modules: Ensure that the Log Module setting is zero  
(0). This setting is used for diagnostic purposes only.  
Restore Defaults: Resets all COM and Terminal settings to  
factory defaults. This button does not reset the Network  
settings.  
Reset Bridge: Reboots the bridge by cycling the power.  
Version Info: Displays the firmware release level for the  
bridge.  
5.2.2  
Network Setup  
The Network Setup enables you to provide a label for the bridge  
and to configure network settings.  
CAUTION!  
Changing a parameter on the Network Setup page may  
interrupt the operation of the ATM/POS Bridge. Contact your  
network administrator before making any changes.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20 en | Configuration  
ATM/POS Bridge  
Bridge Name: Type an optional name for the bridge in the  
Bridge Name input box. This name facilitates recognition of  
the bridge on the network.  
IP Address: Displays the current IP Address for the bridge.  
You can type a new IP Address in the input box.  
Subnet Mask: Displays the current Subnet Mask for the  
bridge. You can type a new Subnet Mask in the input box.  
Default Gateway: Displays the current Gateway Address  
for the bridge. You can type a new Gateway Address in the  
input box.  
Recorder TCP Port: Displays the TCP port number where  
the recorder listens for the bridge device. You can type a  
new port number in the input box.  
Service TCP Port: Displays the TCP port where the bridge  
listens for CLI commands. (The bridge supports CLI  
commands which are used to read and change settings in  
the bridge.)  
Tx Server TCP Port: Displays the TCP port number where  
the bridge listens for the server that receives transaction  
data from the POS or ATM devices on the network. You can  
type a new port number in the input box.  
Device Detection: Enables or disables the Bridge  
Detection utility to find the bridge on a network.  
NOTICE!  
It is recommended to disable this feature once the network  
settings are configured.  
MAC Address: Displays the MAC Address for the bridge.  
This value cannot be changed.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration | en 21  
5.2.3  
Terminal  
The Terminal Setup pages allow you to configure the bridge to  
accept transactions from the ATM/POS devices connected to  
the bridge.  
Name: Type an optional name for the terminal. This name  
facilitates recognition of the terminal on the network  
Device: Select the type of POS or ATM device. You can  
choose one of these options:  
Specific Device: The bridge converts the characters  
from the terminal based on the code page setting of  
the terminal and the recording language selected on  
the bridge System menu.  
Transparent: The bridge receives all characters from  
an ATM/POS terminal in a complete line without  
protocol conversion; then transmits the complete line  
to a recording device. The bridge does not perform  
character conversion.  
Capture: The bridge receives all characters from an  
ATM/POS terminal one character at a time; then  
transmits an individual character to a recording  
device. The bridge does not perform character  
conversion.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22 en | Configuration  
ATM/POS Bridge  
Code Page: Select the code page (character set for a  
particular language) that the ATM/POS terminal uses to  
encode transaction data. The selections are:  
PC437 (Latin 1)  
PC858 (Latin II + EURO)  
PC737 (Greek)  
PC775 (Baltic)  
PC855 (Cyrillic)  
PC857 (Turkish)  
Comm Channel: Select one the following channels that  
connects the terminal to the bridge:  
COM 1 - RS232  
COM 2 - RS232  
COM 3 - RS232 (console)  
COM 4 - RS485  
TCP/IP Server: Select this channel if the ATM/POS  
terminal connects to the bridge via a TCP/IP network.  
None  
Address: If the Comm Channel is set to TCP/IP, use the  
Address field to enter one of the following addresses:  
0.0.0.0: The default IP Address that instructs the  
bridge to accept transactions from any IP Address (or  
ATM/POS terminal) on the network.  
Specific IP Address: Type the IP Address of a specific  
terminal to instruct the bridge to accept transactions  
only from that ATM/POS terminal on this Comm  
Channel.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration | en 23  
5.2.4  
COM Port  
The COM Port page enables you to configure the four physical  
communication port settings on the bridge.  
Comport Mode: Select the appropriate communication  
method between the bridge and the terminal:  
Asynchronous  
Mono synchronous  
Bisynchronous  
Bit Synchronous  
Communication Parameters: Select the appropriate  
settings to match the communication parameters for the  
terminal connected to this port:  
Baudrate  
Databits  
Parity  
Stopbits  
Flow Control  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24 en | Configuration Using HyperTerminal  
ATM/POS Bridge  
6
Configuration Using HyperTerminal  
You can configure the ATM/POS Bridge via a PC HyperTerminal  
session. The PC is connected to the COM 3 (console) port on  
the bridge via a serial connection.  
For instructions to update the ATM/POS Bridge firmware, refer  
to Section A Updating Bridge Firmware, page 36.  
6.1  
6.2  
Connecting the Bridge  
1. Ensure that the bridge is connected to the power supply.  
2. Connect the supplied console cable to COM Port 3  
(console) on the bridge.  
3. Connect the other end of the console cable to a serial port  
on the PC.  
Initiating a HyperTerminal Session  
1. Launch the HyperTerminal application on the PC. This  
application is usually found on the Windows Start menu  
under the Programs -> Accessories -> Communications  
folder.  
2. Type a name for the new HyperTerminal session and select  
an icon for the session, then click OK.  
3. Select the appropriate COM port number on the PC that is  
connected to the bridge, then click OK.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration Using HyperTerminal | en 25  
4. Ensure that the settings in the COM Properties dialog box  
match these settings:  
Bits per second: 9600  
Data bits: 0  
Parity: None  
Stop bits: 1  
Flow control: None  
5. Click OK to accept the COM properties and to start the  
HyperTerminal session.  
6. Refer to Section 6.3 Configuring Bridge Operation via  
HyperTerminal, page 26 for details about configuring the  
bridge operation via HyperTerminal.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26 en | Configuration Using HyperTerminal  
ATM/POS Bridge  
6.3  
Configuring Bridge Operation via  
HyperTerminal  
After you establish a HyperTerminal connection between a PC  
and the bridge, use the menu structure to configure the bridge  
settings. Press the F1 key to open the System Options menu,  
then select 1 - Network Setup.  
6.3.1  
Network Setup  
The Network Setup enables you to provide a label for the bridge  
and to configure network settings.  
CAUTION!  
Changing a parameter on the Network Setup page may  
interrupt the operation of the ATM/POS Bridge. Contact your  
network administrator before making any changes.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration Using HyperTerminal | en 27  
Bridge Name: Type an optional name for the bridge in the  
Bridge Name input box. This name facilitates recognition of  
the bridge on the network.  
IP Address: Displays the current IP Address for the bridge.  
Select option 2 to enter a new IP Address.  
Subnet Mask: Displays the current Subnet Mask for the  
bridge. Select option 3 to enter a new Subnet Mask.  
Default Gateway: Displays the current Gateway Address  
for the bridge. Select option 4 to enter a new Gateway  
Address.  
Recorder TCP Port: Displays the TCP port number where  
the recorder listens for the bridge device. You can type a  
new port number in the input box.  
Service TCP Port: Displays the TCP port where the bridge  
listens for CLI commands. (The bridge supports CLI  
commands which are used to read and change settings in  
the bridge). Select option 6 to enter a new port number.  
Tx Server TCP Port: Displays the TCP port number where  
the bridge listens for the server that receives transaction  
data from the POS or ATM devices on the network. Select  
option 7 to enter a new port number.  
Device Detection: Enables or disables the Bridge  
Detection utility to find the bridge on a network.  
NOTICE!  
It is recommended to disable this feature once the network  
settings are configured.  
MAC Address: Displays the MAC Address for the bridge.  
This value cannot be changed.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28 en | Configuration Using HyperTerminal  
ATM/POS Bridge  
6.3.2  
Communication Channels  
Select the Communication Channel option to configure the four  
physical communication port settings on the bridge.  
Select the appropriate option to configure a specific COM port.  
Comport Mode: Select the appropriate communication  
method between the bridge and the terminal:  
Asynchronous  
Mono synchronous  
Bisynchronous  
Bit Synchronous  
Communication Parameters: Select the appropriate  
settings to match the communication parameters for the  
terminal connected to this port:  
Baudrate  
Databits  
Parity  
Stopbits  
Flow Control  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration Using HyperTerminal | en 29  
6.3.3  
Terminal Setup  
The Terminal Setup pages allow you to configure the bridge to  
accept transactions from the devices connected to the bridge.  
Select a terminal number to configure the settings for that  
terminal.  
Name: Select option 1 to type an optional name for the  
terminal. This name facilitates recognition of the terminal  
on the network  
Device: Select the type of POS or ATM device. You can  
choose one of these options:  
Specific Device: The bridge converts the characters  
from the terminal based on the code page setting of  
the terminal and the recording language selected on  
the bridge System menu.  
Transparent: The bridge receives all characters from  
an ATM/POS terminal in a complete line without  
protocol conversion; then transmits the complete line  
to a recording device. The bridge does not perform  
character conversion.  
Capture: The bridge receives all characters from an  
ATM/POS terminal one character at a time; then  
transmits an individual character to a recording  
device. The bridge does not perform character  
conversion.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 en | Configuration Using HyperTerminal  
ATM/POS Bridge  
Code Page: Select the code page (character set for a  
particular language) that the ATM/POS terminal uses to  
encode transaction data. The selections are:  
PC437 (Latin 1)  
PC858 (Latin II + EURO)  
PC737 (Greek)  
PC775 (Baltic)  
PC855 (Cyrillic)  
PC857 (Turkish)  
Comm Channel: Select option 4 to select one the following  
channels that connects the terminal to the bridge:  
COM 1 - RS232  
COM 2 - RS232  
COM 3 - RS232 (console)  
COM 4 - RS485  
TCP/IP Server: Select this channel if the ATM/POS  
terminal connects to the bridge via a TCP/IP network.  
None:  
Address: Select option 5 to configure the address.  
If the Comm Channel is set to TCP/IP, use the Address  
field to enter one of the following options:  
0.0.0.0: The default IP Address that instructs the  
bridge to accept transactions from any IP Address (or  
ATM/POS terminal) on the network.  
Specific IP Address: Type the IP Address of a specific  
terminal to instruct the bridge to accept transactions  
only from that ATM/POS terminal on this Comm  
Channel.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Configuration Using HyperTerminal | en 31  
6.3.4  
Simulation Mode  
Use the Simulation Mode to select the type of device to test the  
connection between the bridge and the digital recorder. Select  
this mode to send sample data from the bridge to the digital  
recorder.  
This setting is set to Off for normal operation.  
6.3.5  
Recording Language  
Select the language that is set on the digital recorder to ensure  
that characters display correctly.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32 en | Configuration Using HyperTerminal  
ATM/POS Bridge  
6.3.6  
Service Menu  
The System Menu contains settings for bridge operation.  
Restore Defaults: Resets all COM and Terminal settings to  
factory defaults. This button does not reset the Network  
settings.  
Reset Bridge: Reboots the bridge by cycling the power.  
Diagnostics: Select this option to perform the EEPROM  
diagnostic test.  
Version Info: Displays the firmware release level for the  
bridge.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Troubleshooting | en 33  
7
Troubleshooting  
If you are unable to capture transaction data, follow these  
steps:  
1. Check all cable connections.  
2. Check the TCP/IP network connection with the ATM/POS  
Bridge. Ensure that the IP Address, Subnet Mask, and  
Gateway Address are valid and appropriate for the  
network.  
3. If the recorder has established communication with your  
bridge and you cannot capture transaction data, use the  
simulation mode (refer to Section 5.2.1 System Menu,  
page 18) to send sample transactions to the recorder.  
4. Check the COM port settings in the bridge. If the  
transaction data is being recorded, but displays the wrong  
characters, check the COM port settings. The language  
setting in the bridge must be the same as the recorder  
language setting. Refer to Section 5.2.1 System Menu,  
page 18.  
5. Check that the ATM/POS license is enabled in the  
recorder, if necessary.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34 en | Technical Data  
ATM/POS Bridge  
8
Technical Data  
Electrical  
Power Supply External DC power supply (supplied)  
Input: 100–240 VAC, 150 mA, 50/60 Hz  
Output: 12 VDC, 450 mA  
Connector  
Mechanical  
Dimensions  
Weight  
DC jack, positive center pin, 10–30 VDC, 2 W  
152 x 110 x 35 mm (5.98 x 4.33 x 1.38 in.)  
Approximately 0.6 kg (1.3 lb)  
Mounting Kit Supplied  
Interface  
Ethernet  
RJ45 shielded, 10BaseT  
COM 1 Port  
9-pin SubD male connector, RS232  
synchronous or asynchronous signals  
according to EIA/TIA-232-F  
COM 2 Port  
9-pin SubD male connector, RS232  
synchronous or asynchronous signals  
according to EIA/TIA-232-F  
COM 3 Port  
(console)  
9-pin SubD male connector, RS232  
asynchronous signals according to EIA/TIA-  
232-F  
COM 4 Port  
9-pin SubD male connector, RS485  
asynchronous  
Environmental  
Temperature Operating: 0°C to +45°C (+32°F to +113°F)  
Storage: -25°C to +70°C (-13°F to +158°F)  
Relative  
Operating: < 80% non-condensing  
Storage: < 90% non-condensing  
Humidity  
Electromagnetic Compatibility  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
Technical Data | en 35  
EMC  
USA: FCC Part 15, Class B  
Requirements EU: EMC directive 89/336/EEC  
Immunity: EN50130-4  
Emission: EN55022 Class B  
Harmonics: EN61000-3-2  
Voltage Fluctuations: EN61000-3-3  
Safety  
USA: UL60950  
EU: EN60950  
Canada: CAN/CSA - C22.2 - 60950-00  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36 en |  
ATM/POS Bridge  
A
Updating Bridge Firmware  
Follow the steps below to update the firmware on the ATM/  
POS Bridge.  
1. Download the Zip file for the ATM/POS Bridge firmware  
from the Bosch Security Systems Web site  
(www.boschsecurity.com).  
2. Unzip the firmware update file into a folder on the PC that  
you will use to update the bridge.  
3. Run the downloadwizard.exe file to start the update  
process. The PC displays the initial wizard screen.  
4. Click Next to proceed to the Prepare the Bridge step.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
| en 37  
a. Unplug the power cable from the bridge.  
b. Connect the supplied console cable to COM Port 3  
(console) on the bridge and to a COM port on the PC.  
c. Connect the supplied power adapter to the bridge  
and to the main power.  
The red LED light on top of the bridge flashes short  
pulses to indicate that the bridge is in download  
mode.  
NOTICE!  
if the console download cable is attached to the PC via a low-  
end USB to Serial adapter, the firmware download attempt may  
take several attempts before it succeeds. Bosch recommends  
the SIIG USB to Serial serial adapter, a higher-end adapter.  
(Manufacturer Part number: JU-CB1S12-S3)  
5. Click Next to select the PC COM port and to configure the  
bridge communication settings.  
Change the settings for the Baud rate, Data, Parity, and  
Stop parameters to match the settings on the PC.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38 en |  
ATM/POS Bridge  
6. Click Next to select the download parameters.  
7. Click the check boxes to download the Bridge Software  
and the Printer definition and simulation files. A check  
mark indicates that the process will update the specific  
files.  
8. Select the folder where the firmware and printer definition  
files are stored.  
By default, the wizard searches for the file in the same  
directory that contains the downloadwizard.exe file.  
9. To navigate to a different folder, click the ... button to  
select another directory. Then, click OK to return to the  
wizard.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
| en 39  
10. Click Next to select the device profiles that are stored on  
the bridge.  
Select individual check boxes to select specific device  
profiles.  
Click the Select All Devices to select all device  
profiles.  
Click Unselect All Devices to clear the check boxes for  
all device profiles.  
11. Click Next to view a summary of the download settings and  
to start the update process.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
40 en |  
ATM/POS Bridge  
12. Click Finish to accept the settings and to start the  
firmware update. If you receive an error message, refer to  
Page 41.  
13. Click Yes to overwrite the existing files on the bridge.  
The wizard displays a download progress screen.  
DO NOT interrupt the update process.  
14. Click OK once the upload process is complete.  
15. Disconnect the power cable and the console cable from  
COM Port 3 on the bridge.  
16. Reconnect a serial cable from a terminal to COM Port 3, if  
required.  
NOTICE!  
Ensure that the console cable is disconnected from the bridge  
before reconnecting the power.  
17. Reconnect the power cable to the bridge.  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS Bridge  
| en 41  
Troubleshooting Bridge Firmware Update  
Use the following steps to correct the firmware settings If you  
receive the following error during the firmware update process:  
1. Click OK to acknowledge the error.  
2. Click the Cancel button to stop the process and to quite  
the wizard.  
3. Re-launch the downloadwizard.exe file to start the  
update process.  
4. Follow the process until you reach the communications  
setup wizard screen. Use the following values for the  
communication settings:  
Baud Rate: 19200  
Data: 8 bits  
Parity: None  
Stop: 1 bit  
5. Continue through the wizard screens to start the upload  
process.  
Bosch Security Systems, Inc.  
Installation Manual  
F.01U.171.816 | 1.0 | 2010.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42 en |  
ATM/POS Bridge  
F.01U.171.816 | 1.0 | 2010.09  
Installation Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Security Systems, Inc.  
© Bosch Security Systems, Inc., 2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Caulking Gun F8V7D006 SS User Manual
Black Box Network Hardware Black Box 58 GHz 300 Mbps Wireless Ethernet Kit User Manual
Black Decker Cordless Sander BDS1801 User Manual
Black Decker Power Screwdriver 2020 10 User Manual
Black Decker Toaster ET202 User Manual
Bosch Appliances Oven HBC84K50A User Manual
Brother All in One Printer MFC7360N User Manual
Campbell Hausfeld Nail Gun IN727900AV User Manual
Chauvet Scanner Q Roll 150 User Manual
Cisco Systems Network Card 3522 BRI User Manual