Q-Scan™ 150
150W HTI Intelligent Scanner
Q-Roll™ 150
150W HTI Intelligent Barrel Scanner
USER MANUAL
Barrel
Scanner
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
BEFORE YOU BEGIN
What is included
Q-Scan™ 150 with HTI150 bulb
or
Power cord with plug
Manual
Warranty Card
Q-Roll™ 150 with HTI150 bulb
Removable feet
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
Figure 1 - AC Voltage Switch
channel is used solely for a 0% to 100% switch. Before applying power to a
fixture, check that the source voltage matches the fixture’s requirement.
Check the fixture or device carefully to make sure that if a voltage selection
switch exists that it is set to the correct line voltage you will use.
Warning!
Verify that the power select switch on your unit matches the
line voltage applied. All fixtures must be connected to circuits
with a suitable Earth Ground.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
Don’t connect the device to a dimmer pack.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Avoid direct eye exposure to lamp while it is on.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
Q-Scan 150 & Q-Roll 150 User Manual
3
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Technical Features
Q-Scan™ 150
Control Features
Q-Roll™ 150
Control Features
6-7 channel DMX Intelligent Scanner
Pan: 180°
Tilt: 70°
6-7 channel DMX Intelligent Barrel Scanner
Pan: 180°
Barrel Rotation: 360°
Mechanical Dimmer/Shutter/Strobe
Mechanical Dimmer/Shutter/Strobe
Rotating Gobos
Rotating Gobos
- 8 interchangeable rotating gobos
- 6 metal, 2 glass, 2 Free gobos
- Gobo Bounce™
- Gobo wheel spin
- in both directions, at variable speeds
- 8 interchangeable rotating gobos
- 6 metal, 2 glass, 2 Free gobos
- Gobo Bounce™
- Gobo wheel spin
- in both directions, at variable speeds
Color Wheel
- 11 colors plus open
- includes 1 quad and 1 tri-color split
- Rainbow color spin
- in both directions, at variable speeds
Color Wheel
- 11 colors plus open
- includes 1 quad and 1 tri-color split
- Rainbow color spin
- in both directions, at variable speeds
Gobo rotation control channel
Pan speed & reset control channel
Gobo rotation control channel
Pan/Tilt speed & reset control channel
Features
Features
Built in beat activated and automatic programs (stand-
Built in beat activated and automatic programs
(stand-alone)
alone)
LED display menu with invert
Pan/Tilt Invert option
Removable foot stands
Micro-stepping motors
Thermal switch
LED display menu with invert
Pan/Tilt Invert option
Removable foot stands
Micro-stepping motors
Thermal switch
Fan cooled
Fan cooled
DMX Channel Summary
CHANNEL
1
FUNCTION
Pan
2
3
4
5
6
7
Tilt or Barrel Roll
Shutter, Strobe, Dimmer
Rotating Gobos
Colors
Gobo rotation
Pan/Tilt Speed & Reset
with (P7-n) setting
Q-Scan 150 & Q-Roll 150 User Manual
4
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Product Overview
1
1. Scanner head
2
2. Projector
3. Base
4. Carrying handles and
removable floor stands
5. Fan (bottom rear)
6. LED power indicator
7. LED display
8. [Enter] button
9. [Choose] button
10. [Up] button
22
11. [Down] button
12. DMX output
13. DMX input
5
14. Internal microphone
15. AC input IEC 60320 C14
16. Fuse holder
17. Power switch
18. Voltage switch
19. Music Sensitivity Knob
20. Lamp access plate
21. Lamp optimizing
22. Barrel scanner
4
18
3
7
6
Control Board
19
12
Up
10
Down
11
13
14
20
21
17
4
15
16
Enter
Choose
8
9
SEGMENT BUTTONS I/O PANEL OVERVIEW
BUTTONS
Choose
I/O PANEL
Toggles menu functions
DMX Out & In
Power
DMX-512 connectors
Steps backward through menu
functions
Down
Up
AC input IEC 60320 C14 and fuse holder
Steps forward through menu
functions
Confirms selected menu
function
Enter
Q-Scan 150 & Q-Roll 150 User Manual
5
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. An HTI150 high intensity
discharge lamp is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
Lamp Installation
S1
1. Remove screws labeled (S1) and pull out lamp socket plate.
2. If replacing the lamp, remove old lamp first.
3. Holding the new lamp by its base, align the pins on the lamp
with the small hole in the socket and insert the lamp squarely
until the retaining clips on the lamp socket secure the lamp
tightly.
S2
4. Clean the glass/envelope of the bulb with an alcohol wipe or
equivalent.
S1
5. Holding the lamp socket plate, insert the tip of the lamp into the
fixture with extreme care. Navigate the lamp all the way until it
reaches the reflector and the lamp base plate touches the
bottom plate of the fixture.
6. Align the screw holes and fasten the screws back onto the
lamp socket plate.
7. If you are replacing the lamp, you may want to log the fixture
hours in order to track the lamps use. Navigate to the H000 on
the menu display to obtain this information. Please note that it
is normal for the fixture to have logged a few hours of testing
prior to your use.
8. Turn the fixture on and adjust the lamp alignment screws (S2)
until the brightest most even area of the beam is in the center
of your spot. It may be necessary for you to use a controller in order to command the fixture to
display a white beam on a flat surface with no colors.
Maximizing the life of your lamp
To ensure the longest and most efficient use of the lamp always wait
between 10 and 15 minutes before re-applying power after a shutdown.
Failure to do so could result in premature aging of the lamp and failure to
the electronics that drive it.
Q-Scan 150 & Q-Roll 150 User Manual
6
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Lamp Alignment How-To
Often, after a new installation of a lamp, you will find that there
is an uneven field of light or what is referred to as a hot spot.
This is due to the most intense point of the lamp source not
being positioned optimally within the reflector.
S2
There are three lamp alignment screws provided at the base of
the projector head. Turning these screws allow you to optimize
the projection quality of the spot as well as the overall intensity
of the beam.
Lamp Alignment Screws are
accessible via the rear plate.
1. Project a white spot against any flat surface. Preferably the
surface should be white or pastel in color.
2. Turning the lamp alignment screws, try to position the hot spot in the
center of the beam as best as possible. This could require many
attempts on your part.
3. Once the hot spot is in the center of the spot, do your best to turn all
screws equally as to affect movement up or down within the reflector.
4. As you move in and out of optimum lamp focus, you will see the hot spot either gets wider or
narrower. The goal is to either totally diminish the hot spot by having it widen and spread across
the entire spot or moving the hot spot so that it covers as much of the beam spot area as possible.
Power
Your product is equipped with switch-selectable AC power setting.
Slide switch up or down
Warning!
Verify that the power select switch on your unit
depending on your line voltage.
matches the line voltage applied. All fixtures must
be connected to circuits with a suitable Earth
Ground.
To determine the power requirements for a particular fixture,
see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE
BROWN
PIN
Live
INTERNATIONAL
L
N
BLUE
Neutral
Earth
YELLOW/GREEN
EG (Ground)
Exchanging gobos
1. Press both tips of the gobo tension ring together and remove from aperture.
2. Push the gobo with your finger from the back side following the same direction
that the tension ring was removed.
Q-Scan 150 & Q-Roll 150 User Manual
7
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Mounting
Orientation
Both fixtures can sit on stage or be mounted on a truss using a clamp in any position, provided, there
is adequate room for ventilation.
Warning
It is important never to obstruct the fan or vents pathway.
When selecting installation location, take into consideration lamp replacement access and routine
maintenance.
Safety cables should always be used.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme
temperature changes or restricted ventilation.
The fixture must have a minimum of 1 meter distance from combustible materials.
1
2
1. Clamp
2. Fixture Yoke
3. Angle Adjustment
3
Rigging
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.
1. Align the clamp screw with the center hole on the yoke and tighten.
2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.
3. Adjust the angle on the yoke arm as necessary.
Q-Scan 150 & Q-Roll 150 User Manual
8
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
Control Panel
On the control panel you can set the DMX address, set the fixture to Master/Slave mode, reset the
fixture and change fixture personality traits.
Control Board
[Enter] Confirms selection
[Choose] Access to main menu
[Up] Toggle menu items in a forward direction
[Down] Toggle menu items in a reverse direction
Up
Down
Enter
Choose
Control Panel Functions
FUNCTION
OPTIONS
/
/
/
/
/
/
NOTES
Pan invert
Tilt invert
Fixture reset
Stand Alone (Sound-Active)
Stand Alone (Auto Run)
Master Mode
(-n) to Enable Channel 7
Pan/Tilt Speed)
/
Display invert
/
DMX channel addressing
~
-y: Activates setting
-n: Disables, skips or selects alternative setting
Applying changes to Functions (Quick Instructions)
Unless other wise stated changes in the control panel can be applied in the following manner.
1. Press [Choose] button repeatedly until the display reads the menu function you wish to change as
illustrated in the table above in section “Control Panel Functions”
2. The display will read the previously stored settings for the desired function, for example, either
with a “-y” or a “-n” as in “P1-y or P1-n”.
3. Press the [Up] or [Down] button to toggle between either the “-y” or “-n” selection for that
particular menu function.
4. Press the [Enter] button to store your selection. The display will read “PASS” to confirm your
selection
Q-Scan 150 & Q-Roll 150 User Manual
9
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Modes
A stand-alone mode will listen to sound and run through its diverse range of built in programs.
Master/Slave mode will allow the command of up to as many units you want in a synchronized
light show to the sound.
DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be
controlled individually using any universal DMX-512 controller.
Master & Stand Alone (P6)
In order to create the correct environment for Stand Alone
operation, several parameters have to be set in the control
panel. Please make the changes to the functions as listed in
the table below.
Note!
If the fixture is connected to a
controller, please disconnect it.
The display will read the previously
selected setting.
FUNCTION SET TO NOTES
Only one fixture can be the Master
assigned fixture. However, 16 units
can be slaved to the master unit.
P6
P4
A
-y
Master mode (one Master only)
Sound activated
Channel address
Pan invert
-y
001
Any
Any
P1
P2
Tilt invert
Setting Slave Fixtures
The Master/Slave mode will allow you to link multiple units in a daisy chain fashion. In this mode, the
first unit in the daisy chain, the master, will automatically command all other units following. The first
unit will operate in a Stand/Alone mode and all units following will synchronize to the first unit. Up to
16 fixtures can be daisy chained in Master/Slave mode.
MENU SET TO NOTES
P6
P4
A
-n
Master mode
Sound activated
Channel address
Pan invert
-n
001
Any
Any
P1
P2
Tilt invert
You can change the Pan and Tilt settings freely.
Sound-active (P4) or Auto-run (P5)
In Master/Slave mode you can choose whether the fixture will run in a sound-active state where the
movement is triggered by sound or in auto-run where the speed is pre-programmed.
MENU SET TO NOTES
P4
or
-n
Sound Activated
P5
-n
Auto-run
Q-Scan 150 & Q-Roll 150 User Manual
10
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
DMX Mode
Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to
customizing or creating a show. You can tailor your programming to suit a specific event. Whether it
is a wedding where a spot light may be required or a lead singer requiring a color solo, the
opportunities are endless. In this mode you will be able to control each individual trait of the fixture
independently.
Daisy Chain Connection
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
Daisy Chain Connection
Menu Functions
DMX-512 addressing
This mode enables the use of a universal DMX controller device. Each fixture requires a "start
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data
on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels
of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101,
102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate
the start address selected for future reference.
If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping
to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that
will help you understand its use.
Setting the starting address
1. Press the [Choose] button until the display reads “ANNN” where N represents a number from 0 to
9.
2. Press the [Up] and [Down] buttons to increase or decrease values until the desired value is
achieved.
3. Press the [Enter] button to activate selection.
Q-Scan 150 & Q-Roll 150 User Manual
11
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
User Configurations
P1 - Pan Invert / P2- Tilt Invert
It is possible to invert the pan and tilt mirror movement from within the fixture itself. This could be
helpful in situations where the positioning or rigging of a fixture led to a reverse orientation of the
fixture in relation to all or most other fixtures installed. When choosing to command the pan or tilt of
all fixtures at the same time you will notice that the fixtures whose orientation is different from the
others will most likely move opposite of the rest. You can apply a pan and tilt Invert by following the
settings in the table below.
FUNCTION SET TO NOTES
P1
-y
-y
-n
Pan Invert
P2
P1 & P2
Tilt Invert
Return to normal
Segment Display Configurations
The display can be inverted making it easier to read the menu depending on the orientation of your
fixture.
P8 - Display Invert
FUNCTION SET TO NOTES
P8
P8
-y
-n
Invert display
Return to normal
Service Functions
P3 - Fixture Reset (all motors)
This function will re-initialize the fixture by returning all motors to its startup positions or otherwise
known as (home position).
FUNCTION SET TO NOTES
P3
P3
-y
-n
Reset fixture
Skip function
Q-Scan 150 & Q-Roll 150 User Manual
12
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Figure 2 - DMX connector configuration
Resistance 120
1
ohm 1/4w between
3
pin 2 (DMX -) and
pin 3 (DMX +) of
2
COMMON
the last fixture.
1
1
3
DMX +
DMX -
INPUT
3
OUTPUT
Termination reduces signal errors and to
avoid signal transmission problems and
interference, it is always advisable to
connect a DMX signal terminator.
2
2
Fixture Linking
Note!
If you use a controller with a 5 pin DMX output connector, you will need to use a 5
pin to 3 pin adapter. CHAUVET Model No: DMX5M.
The chart below details a proper cable conversion:
3 PIN TO 5 PIN CONVERSION CHART
Conductor
Ground/Shield
Data ( - )signal
Data ( + ) signal
Do not use
3 Pin Female (output)
5 Pin Male (Input)
Pin 1
Pin 1
Pin 2
Pin 3
Pin 2
Pin 3
Do not use
Do not use
Do not use
Q-Scan 150 & Q-Roll 150 User Manual
13
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
DMX Channel Values (16 Bit)
DEFAULT
1
VALUE
FUNCTION
Pan
000 255
000 255
Left > Right ( 128 = center)
Tilt (Q-Scan 250)
Up > Down (128 = center)
Barrel Spin (Q-Roll 250)
Stop
Rotation: Fast > Slow (clockwise)
Stop
Rotation: Slow > Fast (counter-clockwise)
2
000 005
005 120
121 140
141 255
Shutter/Strobe/Dimmer
000 005
006 063
064 095
096 127
128 159
160 191
192 223
224 255
Blackout
Dimmer: Closed > Open (0-100%)
Variable strobe: Slow > Fast
Open
3
(no function)
Pulse strobe in sequence: Slow > Fast | (Close > Open)
Pulse strobe in sequence: Fast > Slow | (Open > Close)
Open
Rotating Gobo Wheel
000 013
014 027
028 041
042 055
056 069
070 083
084 097
098 111
112 126
127 136
137 146
147 156
157 166
167 176
177 186
187 196
197 206
207 217
218 219
220 255
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Open
4
Gobo 1 (variable bounce): Slow > Fast
Gobo 2 (variable bounce): Slow > Fast
Gobo 3 (variable bounce): Slow > Fast
Gobo 4 (variable bounce): Slow > Fast
Gobo 5 (variable bounce): Slow > Fast
Gobo 6 (variable bounce): Slow > Fast
Gobo 7 (variable bounce): Slow > Fast
Gobo 8 (variable bounce): Slow > Fast
Open
Gobo spin: Slow > Fast
Color Wheel
000 009
010 020
021 031
032 041
042 052
053 063
064 073
074 084
085 095
096 105
106 116
117 128
129 190
191 220
221 222
223 255
White (Open)
Red
Blue
Yellow
Light Green
Magenta
UV
Light Blue or Cyan
Orange
Pink
Tri-color: Red – White - Blue
Quad-color: Blue – Pink – Purple - Yellow
Linear progression of color wheel (color-splits)
Rainbow effect: Fast > Slow (clockwise)
Stop
5
Rainbow effect: Slow > Fast (counter-clockwise)
Gobo Rotation
000 127
128 189
190 193
194 255
Gobo incremental rotation
Clockwise gobo rotation: Fast > Slow
No Rotation
6
7
Counter clockwise gobo rotation: Slow > Fast
Pan/Tilt Speed (P7-n setting)
Tracking control: Maximum
Vector control: Maximum > Slowest
Fixture Reset (hold 3 to 5 seconds)
Tracking control: Maximum
000 000
001 200
201 204
205 255
Q-Scan 150 & Q-Roll 150 User Manual
14
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or
becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
Q-Scan 150 & Q-Roll 150 User Manual
15
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
General Troubleshooting
Applies to
Foggers
Dimmers
& Chaser
Symptom
Solution(s)
Lights
& Snow
Controllers
Auto shut off
Check fan thermal switch reset
Beam is very dim or not Clean optical system or replace lamp
bright
Check 220/110v switch for proper setting
Check total load placed on device
Breaker/Fuse keeps
blowing
Chase is too slow
Check users manual for speed adjustment
Device has no power
Check for power on Mains.
Check device’s fuse. (internal and/or external)
Fixture is not responding Check DMX Dip switch settings for correct addressing
Check DMX cables
Check polarity switch settings
Fixture is on but there is Make sure you have the correct audio mode on the control
no movement to the
audio
switches. If audio provided via ¼” jack, make sure a live audio
signal exists
Adjust sound sensitivity knob
Lamps cuts off
sporadically
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
Light will not come on
after power failure
Some discharge lamps require a cooling off period before the
electronics in the fixture can kick start it again, wait 5 to 10
minutes before powering up
Loss of signal
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black
lights.
Motor movements are
jerky or jumpy
Possible bad motor driver or sensors
Check polarity switch on controller
Moves slow
Check 220/110v switch for proper setting
No flash
Re-install bulb, may have shifted in shipping
No light output
Check slip ring & brushes for contact
Install bulb
Call service technician
Relay will not work
Check reset switch
Check cable connections
Remote does not work
Stand alone mode
Make sure connector is firmly connected to device
All CHAUVET lighting fixtures featuring stand-alone functions
do not require additional settings, simply power the fixture and
it will automatically enter into this mode
Unit wobbles when
rotating
Check for damages possibly incurred during shipping
Q-Scan 150 & Q-Roll 150 User Manual
16
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Technical Specifications
WEIGHT & DIMENSIONS
Length........................................................................................................................292 mm (11.5 in)
Width.............................................................................................................................305 mm (12 in)
Height ...........................................................................................................................736 mm (29 in)
Weight......................................................................................................................12.70 Kgs (28 lbs)
POWER
Switch-selectable power settings.................................................................115V 60 Hz or 230V 50 Hz
AC input.........................................................................................................3 prongs IEC 60320 C14
European version............................................................................................................... 240V 50 Hz
Current draw 110V................................................................................... (peak 287W), (inrush 419W)
Current draw 230V................................................................................... (peak 288W), (inrush 431W)
LAMPS
HTI150................................................................................................................ 750 hr, 6500K, 150W
PHOTO OPTIC
Beam Angle .................................................................................................................................... 16°
Pan ............................................................................................................................................... 180°
Tilt................................................................................................................................................... 70°
GOBOS
Outside diameter....................................................................................................................27.69mm
Image diameter........................................................................................................................21.5mm
Thickness......................................................................................................................................3mm
THERMAL
Maximum ambient temperature......................................................................................... 40° (104° F)
FUSE
Main (115V) ............................................................................................. 20mm Glass 6.3A Fast Blow
Internal PCB................................................................................................ 20mm Glass 5A Fast Blow
CONTROL & PROGRAMMING
Data input ............................................................................................. locking 3-pin XLR male socket
Data output ........................................................................................ locking 3-pin XLR female socket
Data pin configuration ............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols.....................................................................................................................DMX-512 USITT
DMX Channels.............................................................................................................................6 or 7
ORDERING INFORMATION
Q-Spot™ 150 Intelligent Scanner........................................................................................Q-Spot 150
Q-Roll™ 150 Intelligent Barrel Scanner................................................................................Q-Roll 150
Fuse 6.3A ..................................................................................................................... P170FUSE006
Fuse 5A ........................................................................................................................ P170FUSE005
Technical Support
Address:
Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
(954) 929-1115 - (Press 4)
(954) 929-5560 - (Attention: Service)
Support (Email):
Telephone:
Fax:
Q-Scan 150 & Q-Roll 150 User Manual
17
2005-11-15/13:23
Download from Www.Somanuals.com. All Manuals Search And Download.
|