DC2000 Back-Up Wiring for the OmniControl™ Board
with Optional Equipment
SAFETY OPTIONS
System Setup
“Manual” setting: The DC2000 will respond to the input devices wired to the J 20 socket.
This mode can also be used as an emergency override. If 115 Vac power is on, but the system has an electronic
malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket.
“Optional Edge Sensor”
“Auto” setting: The DC2000 opens the gate automatically upon 115 Vac power failure and stays open. When
115 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual
command)
EMERGENCY
OVERRIDE
If 115 Vac power is on, but the system has
an electronic malfunction, the gate can be
operated using the DC2000 system with
ANY of these devices shown.
115 Vac Power
Failure
115 Vac Power On,
OmniControl Board™ Malfunction
115 Vac Power On,
Emergency Override
Turn the 115 Vac power off then
push and Hold to operate gate
Push and Hold to override
the OmniControl™ Board
Push and Hold to
operate gate
Manual
Mode
Gate automatically
opens
Turn the 115 Vac power off then
gate opens automatically
Push and Hold to override
the OmniControl™ Board
Auto
Mode
A
A
M
“Optional Manual One-Button”
“Optional Photocell Sensor” 12 VDC
DC-BACKUP
S
N
Push and “Hold” to Open
Push again and “Hold” to Close
POWER
OVERLOAD
Part # AOMRON12V
OmniControl™ Board
Sensor Connection
Part # AEXITP
USE ONLY 12 VDC FAILSAFE PHOTOCELL
SENSORS FOR THIS SAFETY OPTION
Failsafe Photocell: If a photocell is not
working or loses power or photo beam is
blocked, then the photocell will stop all gate
operation.
Power Ground
4
4
5
6
Power +12 VDC
“Optional Key Switch”
5
4
7
E
6
S
O
L
5
C
N
E
P
4
O
3
2
1
If the DC2000 is automatically opening the gate
due to a power failure, any manual command
such as “Manual One-Button”, “Three Push
Button”, “Key Switch”, “Photocell” or “Edge
Sensor” will cancel the automatic mode of the
DC2000. After such cancellation, the DC2000
will continue to operate in manual mode until
115 Vac power is restored.
J 20
DO NOT wire
115 Vac power
to the DC2000
4
3
Socket
Part # A1KX
Interlock Ass
embly Wire
Turn and “Hold” to Open
Turn again and “Hold” to Close
To Limit Switches
Interlock
“Optional Three-Button”
Assembly
3
4
Com
N.O.
CENTER
SAFETY
EXIT
2
1
4
4
Com
Com
N.O.
N.O.
“Optional Radio Receivers”
M
A
L
A
R
O
S
Push and “Hold” a Button to operate
DC-BACKUP
N
E
S
W4
G
B
A
SYSTEM ON
ER
MS LINK
POWER
OVERLOAD
SENSORS
Refer to Receiver
60
3
Manual for Further
Details about settings.
1
3
E
R
R
S
M
OFF
ON
O
O
R
R
S
S
E
A
N
N
V
L
1
3
1
E
E
E
A
S
S
VDC
R
O E N
OPEN LEFT
OPEN RIGHT
ver
12
Part #312HM
ecei
D
DO NOT remove existing
wires from the audio alarm or
secondary protection sensor.
.
STRIKE
OPEN
RADIO
RECEIVER
GATE
S T O P
D
E
arate
Sep
N
S
LOCKED
A
S
E
M
C
M
Jumper P2:
to Constant (C)
O
O
6
5
R
C
P
1
EXIT
LOOP
SAFETY
LOOP
CENTER
LOOP
RESET
MOTOR
4
4
C
L
S
E
000 Radio R
2
DC2
Jumper P3:
3
to 12 Volt
P/N Q410
4
urge Suppressor
OmniContrS
Pate1nt1Pen1din2g 13
+
Class 2
Supply
A L A R M
J5
J5
Red Wire
Cent
L
Safety
Loop
E
Fire Dept
Strike Open
Rdio
Reeiver
G
B
A
Button Three:
Optional Accessories
24 Volts DC
LKeitch Push Button
M/S Link
Button One:
Normal Gate
Operation
DCUP
White Wire
Button Two:
Back-Up Operation
(DC2000)
DC
CHASSIS
G
S E N S O R
24 V
(OmniControl™ Board)
nstalled
®
11
Audio Alarm
Wires
1
tory I
13
2
3
4
eiver
Fac
11
Rec
12
io
Rad
Part #373LM
POWER
Button One:
Normal Gate Operation Only
OVERLOAD
Green and Purple wires
wrap behind board to
the limit switches
(OmniControl™ Board)
4
3
Factory installed
Interlock Assembly
Wires to J20 Socket
Cut and
Discard Plug
Push and “Hold” DC2000 Remote Button to Open
Push again and “Hold” DC2000 Remote Button to Close
DC2000 Harness
Radio Receiver +
Radio Receiver -
13
For Technical Support
and Ordering Parts:
1-800-528-2806
12
11
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|