Chamberlain Stud Sensor DC2000 User Manual

DC2000 Back-Up Wiring for the OmniControl™ Board  
with Optional Equipment  
SAFETY OPTIONS  
System Setup  
“Manual” setting: The DC2000 will respond to the input devices wired to the J 20 socket.  
This mode can also be used as an emergency override. If 115 Vac power is on, but the system has an electronic  
malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket.  
“Optional Edge Sensor”  
“Auto” setting: The DC2000 opens the gate automatically upon 115 Vac power failure and stays open. When  
115 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual  
command)  
EMERGENCY  
OVERRIDE  
If 115 Vac power is on, but the system has  
an electronic malfunction, the gate can be  
operated using the DC2000 system with  
ANY of these devices shown.  
115 Vac Power  
Failure  
115 Vac Power On,  
OmniControl Board™ Malfunction  
115 Vac Power On,  
Emergency Override  
Turn the 115 Vac power off then  
push and Hold to operate gate  
Push and Hold to override  
the OmniControl™ Board  
Push and Hold to  
operate gate  
Manual  
Mode  
Gate automatically  
opens  
Turn the 115 Vac power off then  
gate opens automatically  
Push and Hold to override  
the OmniControl™ Board  
Auto  
Mode  
A
A
M
“Optional Manual One-Button”  
“Optional Photocell Sensor” 12 VDC  
DC-BACKUP  
S
N
Push and “Hold” to Open  
Push again and “Hold” to Close  
POWER  
OVERLOAD  
Part # AOMRON12V  
OmniControl™ Board  
Sensor Connection  
Part # AEXITP  
USE ONLY 12 VDC FAILSAFE PHOTOCELL  
SENSORS FOR THIS SAFETY OPTION  
Failsafe Photocell: If a photocell is not  
working or loses power or photo beam is  
blocked, then the photocell will stop all gate  
operation.  
Power Ground  
4
4
5
6
Power +12 VDC  
“Optional Key Switch”  
5
4
7
E
6
S
O
L
5
C
N
E
P
4
O
3
2
1
If the DC2000 is automatically opening the gate  
due to a power failure, any manual command  
such as Manual One-Button, Three Push  
Button, Key Switch, Photocellor Edge  
Sensorwill cancel the automatic mode of the  
DC2000. After such cancellation, the DC2000  
will continue to operate in manual mode until  
115 Vac power is restored.  
J 20  
DO NOT wire  
115 Vac power  
to the DC2000  
4
3
Socket  
Part # A1KX  
Interlock Ass  
embly Wire  
Turn and “Hold” to Open  
Turn again and “Hold” to Close  
To Limit Switches  
Interlock  
“Optional Three-Button”  
Assembly  
3
4
Com  
N.O.  
CENTER  
SAFETY  
EXIT  
2
1
4
4
Com  
Com  
N.O.  
N.O.  
“Optional Radio Receivers”  
M
A
L
A
R
O
S
Push and “Hold” a Button to operate  
DC-BACKUP  
N
E
S
W4  
G
B
A
SYSTEM ON  
ER  
MS LINK  
POWER  
OVERLOAD  
SENSORS  
Refer to Receiver  
60  
3
Manual for Further  
Details about settings.  
1
3
E
R
R
S
M
OFF  
ON  
O
O
R
R
S
S
E
A
N
N
V
L
1
3
1
E
E
E
A
S
S
VDC  
R
O E N  
OPEN LEFT  
OPEN RIGHT  
ver  
12  
Part #312HM  
ecei  
D
DO NOT remove existing  
wires from the audio alarm or  
secondary protection sensor.  
.  
STRIKE  
OPEN  
RADIO  
RECEIVER  
GATE  
S T O P  
D
E
arate  
Sep  
N
S
LOCKED  
A
S
E
M
C
M
Jumper P2:  
to Constant (C)  
O
O
6
5
R
C
P
1
EXIT  
LOOP  
SAFETY  
LOOP  
CENTER  
LOOP  
RESET  
MOTOR  
4
4
C
L
    S
    E
000 Radio R  
2
DC2  
Jumper P3:  
3
to 12 Volt  
P/N Q410  
4
urge Suppressor  
OmniContrS  
Pate1nt1Pen1din2g 13  
+
Class 2  
Supply  
A L A R M  
J5  
J5  
Red Wire  
Cent
L
Safety  
Loop  
E
Fire Dept  
Strike Open  
Rdio  
Reeiver  
G
B
A
Button Three:  
Optional Accessories  
24 Volts DC  
LKeitch Push Button  
M/S Link  
Button One:  
Normal Gate  
Operation  
DC
-B
A
CK
UP  
White Wire  
Button Two:  
Back-Up Operation  
(DC2000)  
DC  
CHASSIS  
G
S E N S O R  
24 V  
(OmniControl™ Board)  
nstalled  
®
11  
Audio Alarm  
Wires  
1
tory I  
13  
2
3
4
eiver  
Fac  
11  
Rec  
12  
io  
Rad  
Part #373LM  
POWER  
Button One:  
Normal Gate Operation Only  
OVERLOAD  
Green and Purple wires  
wrap behind board to  
the limit switches  
(OmniControl™ Board)  
4
3
Factory installed  
Interlock Assembly  
Wires to J20 Socket  
Cut and  
Discard Plug  
Push and “Hold” DC2000 Remote Button to Open  
Push again and “Hold” DC2000 Remote Button to Close  
DC2000 Harness  
Radio Receiver +  
Radio Receiver -  
13  
For Technical Support  
and Ordering Parts:  
1-800-528-2806  
12  
11  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Power Supply AP51300fc10 BLK User Manual
Belkin Speaker 157 User Manual
Black Decker Blender BLM2600G User Manual
Black Decker Vacuum Cleaner PV1205 User Manual
Briggs Stratton Yard Vacuum 37610701 04 User Manual
Bush Hog Saw 00786976C User Manual
Candy Washer CE 104 1 User Manual
Cannon Electric Pressure Cooker C60DH User Manual
CDA Ventilation Hood EVCK4 User Manual
Chauvet Laser Pointer Laser Pointer User Manual