Cabletron Systems Switch 7F06 02 User Manual

7F06-02 FDDI SmartSWITCH™  
Interface Module  
User’s Guide  
9031672-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
FCC NOTICE  
This device complies with Part 15 of the FCC rules. Operation is  
subject to the following two conditions: (1) this device may not  
cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause  
undesired operation.  
NOTE: This equipment has been tested and found to comply with  
the limits for a Class A digital device, pursuant to Part 15 of the  
FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is  
operated in a commercial environment. This equipment uses,  
generates, and can radiate radio frequency energy and if not  
installed in accordance with the operator’s manual, may cause  
harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause interference in  
which case the user will be required to correct the interference at his  
own expense.  
WARNING: Changes or modifications made to this device which  
are not expressly approved by the party responsible for compliance  
could void the user’s authority to operate the equipment.  
DOC NOTICE  
This digital apparatus does not exceed the Class A limits for radio  
noise emissions from digital apparatus set out in the Radio  
Interference Regulations of the Canadian Department of  
Communications.  
Le présent appareil numérique n’émet pas de bruits  
radioélectriques dépassant les limites applicables aux appareils  
numériques de la class A prescrites dans le Règlement sur le  
brouillage radioélectrique édicté par le ministère des  
Communications du Canada.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
VCCI NOTICE  
This equipment is in the 1st Class Category (information  
equipment to be used in commercial and/or industrial areas) and  
conforms to the standards set by the Voluntary Control Council for  
Interference by Information Technology Equipment (VCCI) aimed  
at preventing radio interference in commercial and/or industrial  
areas.  
Consequently, when used in a residential area or in an adjacent area  
thereto, radio interference may be caused to radios and TV  
receivers, etc.  
Read the instructions for correct handling.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
CHAPTER 1 INTRODUCTION  
1.1 USING THIS MANUAL .........................................................................1-1  
1.2 THE 7F06-02 MODULE...........................................................................1-2  
1.2.1 Cable Type and FPIMs ..................................................................1-2  
1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch  
and the 7C04-R Workgroup SmartSwitch ..................................1-3  
1.3 FEATURES ................................................................................................1-4  
1.3.1 FPIMs...............................................................................................1-4  
1.3.2 LANVIEW LEDs............................................................................1-4  
1.3.3 Connectivity....................................................................................1-4  
1.4 RELATED MANUALS ............................................................................1-5  
1.5 GETTING HELP.......................................................................................1-5  
CHAPTER 2 NETWORK REQUIREMENTS  
2.1 FPIM MODULE SPECIFICATIONS......................................................2-1  
2.1.1 FPIM-00 and FPIM-01 ...................................................................2-1  
2.1.2 FPIM-02 and FPIM-04 ...................................................................2-3  
2.1.3 FPIM-05 and FPIM-07 ...................................................................2-4  
CHAPTER 3 INSTALLATION/REMOVAL  
3.1 UNPACKING THE 7F06-2 MODULE...................................................3-1  
3.2 INSTALLING FPIMS...............................................................................3-1  
3.3 INSTALLING/REMOVING THE 7F06-02 MODULE.......................3-2  
3.3.1 Installing in the 7C03 SmartSwitch .............................................3-2  
3.3.2 Removing from the7C03 SmartSwitch........................................3-3  
3.3.3 Installing in the 7C04 or 7C04-R Workgroup SmartSwitch .....3-5  
3.3.4 Removing from the 7C04 or 7C04-R Workgroup SmartSwitch.3-  
7
CHAPTER 4 TROUBLESHOOTING  
CHAPTER 5 TECHNICAL SPECIFICATIONS  
5.1 STANDARDS............................................................................................5-1  
5.2 EMI.............................................................................................................5-1  
5.3 EMC ...........................................................................................................5-1  
5.4 NETWORK INTERFACES......................................................................5-1  
5.5 SAFETY......................................................................................................5-2  
5.6 SERVICE....................................................................................................5-2  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
5.7 PHYSICAL ................................................................................................5-2  
5.7.1 Dimensions .....................................................................................5-2  
5.7.2 Weight..............................................................................................5-2  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1  
INTRODUCTION  
Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface  
Module User’s Guide. This guide is a simple reference for installing  
and using the 7F06-02 Module. Before installing this module, you  
should carefully read through this manual to gain a full  
understanding of its capabilities.  
The 7F06-02 Module is a two port FDDI module. This module  
connects to a network and the 7X00 SmartSwitch™ Control  
Module in the 7C03,7C04 or 7C04-R MMAC SmartSwitch via a  
SmartSwitch bus.  
1.1 USING THIS MANUAL  
Chapter 1, Introduction, discusses the capabilities and special  
features of Cabletron Systems 7F06-02 Module. This chapter also  
includes a list of related manuals.  
Chapter 2, Network Requirements, contains a list of available  
FPIMs and the network requirements that should be considered  
before installing the 7F06-02 Module.  
Chapter 3, Installation/Removal, contains instructions for  
installing and removing the 7F06-02 in the 7C03 MMAC  
SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R  
Workgroup SmartSwitch.  
Chapter 4, Troubleshooting, contains instructions for using  
LANVIEW® (Cabletron Systems built-in diagnostic and status  
monitoring system).  
Chapter 5, Technical Specifications, provides detailed information  
about the physical characteristics of the 7F06-02 Module.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
1.2 THE 7F06-02 MODULE  
The 7F06-02 Module provides two Fiber Optic ports via front panel  
FPIM modules.  
1.2.1 Cable Type and FPIMs  
The 7F06-02 module has two front panel connectors that interface  
to the 7X00 Smart Switch Module through the chassis backplane.  
The front panel connections are standard Cabletron FPIMs. There  
are two FPIMs for each channel. These FPIMs allow the use of  
single mode or multimode fiber cable with MIC or SC type  
connectors and twisted pair cable, either shielded or unshielded.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
7F06-02  
SP  
A
F
D
D
I
SN  
P
A
B
S
1
B
A
F
D
D
I
A
B
P
S
2
B
Figure 1-1. 7F06-02 Module  
1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup  
SmartSwitch and the 7C04-R Workgroup  
SmartSwitch  
The 7F06-02 Module is designed to be installed in the 7C03 MMAC  
SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R  
Workgroup SmartSwitch.  
The modular design of the 7C03 MMAC SmartSwitch allows other  
modules that support Ethernet, Fast Ethernet, ATM, FDDI, or  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Token Ring to be used with the 7F06-02 Module. These modules  
provide the capability to share data without the use of external  
bridges or routers.  
The 7C03 MMAC SmartSwitch is a unique module that can be  
installed in an MMAC Series chassis. The 7C04 Workgroup  
SmartSwitch and the 7C04-R Workgroup SmartSwitch are stand-  
alone chassis that provide the same functions.  
1.3 FEATURES  
The 7F06-02 Module provides two FDDI ports via front panel  
FPIMs. The 7F06-02 Module includes the following features:  
1.3.1 FPIMs  
The front panel connections are standard Cabletron FPIMs. These  
FPIMs allow the use of single mode or multimode fiber cable with  
MIC or SC type connectors.  
1.3.2 LANVIEW LEDs  
The 7F06-02 uses LANVIEW, Cabletron Systems built-in visual  
diagnostic and status monitoring system. With LANVIEW LEDs,  
you can quickly identify, at a glance, the status of the device  
connected to a port on the 7F06-02 Module.  
1.3.3 Connectivity  
The 7F06-02 Module has one backplane connection and two sets of  
A/B front panel FPIM connections. The backplane connection  
provides power to the 7F06-02 Module and a channel for  
communication with the 7X00 SmartSwitch Control Module. The  
two front panel FPIMs provide FDDI connections, allowing the use  
of single mode or multimode fiber cable with MIC or SC type  
connectors.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
1.4 RELATED MANUALS  
The manuals listed below should be used to supplement the  
procedures and other technical data provided in this manual. The  
procedures will be referenced, where appropriate, but will not be  
repeated.  
7X00 SmartSwitch Control Module User’s Guide  
7F06-02 Local Management Appendix  
7C03 MMAC SmartSwitch Installation Guide  
7C04 Workgroup SmartSwitch Installation Guide  
7C04-R Workgroup SmartSwitch Installation Guide  
1.5 GETTING HELP  
If you need additional support with the 7C03 MMAC  
SmartSWITCH, or if you have any questions, comments or  
suggestions concerning this manual, contact Cabletron Systems  
Technical Support:  
By phone:  
(603) 332-9400  
By fax:  
(603) 337-3075  
By World Wide Web:  
GO CTRON from any ! prompt  
(603) 335-3358  
®
By CompuServe :  
By Internet mail:  
By BBS:  
By mail:  
Cabletron Systems, Inc.  
P.O. Box 5005  
Rochester, NH 03866-5005  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2  
NETWORK REQUIREMENTS  
Before installing Cabletron Systems 7F06-02 Module, review the  
network requirements outlined in this chapter. All requirements  
included in this chapter should be met to ensure satisfactory  
performance of the 7F06-02 Module. Failure to do so may result in  
unsatisfactory network performance.  
Appendix A  
2.1 FPIM MODULE SPECIFICATIONS  
This module uses Fiber Port Interface Modules (FPIM) to provide  
front panel cable connections. The FPIMs are user-installable. See  
2.1.1 FPIM-00 and FPIM-01  
The FPIM-00 and FPIM-01 provide a multimode fiber connection.  
The FPIM-00 uses a MIC style connector and the FPIM-01 uses an  
SC type connector. The specifications for both devices are listed in  
Table 2-1.  
Table 2-1. FPIM-00 and FPIM-01 Specifications  
Worst  
Case  
Budget  
Typical  
Value  
Worst  
Case  
Typical  
Budget  
Parameter  
Receive  
Sensitivity  
-30.5 dBm  
-7.6 dBm  
-28.0 dBm  
-8.2 dBm  
Peak Input  
Power  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NETWORK REQUIREMENTS  
Transmitter power parameters are listed in Table 2-2.  
Table 2-2. Transmitter Power Parameters  
Worst  
Case  
Budget  
Typical  
Value  
Worst  
Case  
Typical  
Budget  
Parameter  
50/125 µm  
-13.0 dBm  
-10.0 dBm  
-7.0 dBm  
-15.0 dBm  
-12.0 dBm  
-9.0 dBm  
13.0 dB  
16.0 dB  
19.0 dB  
17.5 dB  
20.5 dB  
23.5 dB  
fiber  
62.5/125  
µm fiber  
100/140  
µm fiber  
Error Rate  
Betterthan  
10-10  
The link distance is up to 2 kilometers on the multimode fiber-  
optic cable as specified by ANSI MMF-PMD.  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NETWORK REQUIREMENTS  
2.1.2 FPIM-02 and FPIM-04  
The FPIM-02 has an RJ-45 connector supporting an Unshielded  
Twisted Pair (UTP) connection. The FPIM-04 has an RJ-45  
connector supporting a Shielded Twisted Pair (STP) connection.  
The pinouts for both are listed in Table 2-3.  
Table 2-3. FPIM-02 and FPIM-04 Pinouts  
Pin Number  
Represents  
Transmit+  
Transmit-  
NA  
Pin Number  
Represents  
NA  
1
5
NA  
2
3
4
6
7
8
Receive+  
Receive-  
NA  
The link distance is up to 100 meters on unshielded twisted pair  
cable as specified by ANSI TP-PMD.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NETWORK REQUIREMENTS  
2.1.3 FPIM-05 and FPIM-07  
The FPIM-05 and FPIM-07 provide a Single-mode fiber connection.  
The FPIM-05 uses a MIC style connector and the FPIM-07 uses an  
SC type connector. The specifications for both devices are listed in  
Table 2-4.  
Table 2-4. FPIM-05 and FPIM-07 Specifications  
Parameter  
Typical  
Minimum Maximum  
Transmitter Peak  
Wave Length  
1300 nm  
1270 nm  
1330 nm  
Spectral Width  
Rise Time  
60 nm  
-
100 nm  
5.0 nsec  
5.0 nsec  
50.7%  
3.0 nsec  
2.5 nsec  
50.1%  
2.7 nsec  
2.2 nsec  
49.6%  
Fall Time  
Duty Cycle  
Bit Error Rate  
Better  
than 10-10  
The link distance is up to 40 kilometers (max) and 25 kilometers  
(typical) on single mode fiber-optic cable as specified by ANSI  
SMF-PMD.  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3  
INSTALLATION/REMOVAL  
This chapter contains instructions for unpacking and installing the  
7F06-2 Module in the:  
• 7C03 MMAC SmartSwitch  
• 7C04 Workgroup SmartSwitch  
• 7C04-R Workgroup SmartSwitch.  
Also included in the chapter are instructions the front panel FPIMs.  
3.1 UNPACKING THE 7F06-2 MODULE  
Unpack the 7F06-2 Module by using the following steps:  
1. Carefully remove the module from the shipping box. (Save the  
box and packing materials in the event the module must be  
reshipped.)  
2. Remove the module from the plastic bag. Observe all  
precautions to prevent damage from Electrostatic Discharge  
(ESD).  
3. Carefully examine the module and check for damage. If damage  
exists, DO NOT install the module; contact Cabletron Systems  
Technical Support.  
3.2 INSTALLING FPIMS  
The 7F06-02 module is shipped without FPIMs. To install an FPIM,  
follow the procedure below:  
1. Remove the module if it is installed in the 7C03 MMAC  
SmartSWITCH chassis by reversing the procedure in  
Section 3.3.  
2. Remove the blank front cover over the FPIM slot.  
3. Install the FPIM as shown in Figure 3-1. Ensure that the rear  
connector is seated firmly before tightening the two mounting  
screws.  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION/REMOVAL  
Figure 3-1. Installing an FPIM  
3.3 INSTALLING/REMOVING THE 7F06-02 MODULE  
The following procedure detail the installing and removal procedure for  
the 7F06-02 module.  
3.3.1 Installing in the 7C03 SmartSwitch  
The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch  
using the following steps and referring to Figure 3-2.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION/REMOVAL  
Notes: The left most slot in the 7C03 MMAC SmartSwitch is reserved for  
the 7X00 SmartSwitch Module.  
Before installing the 7F06-02 module, attach the wrist strap  
included with the SmartSwitch or SmartSwitch module by  
following the instructions printed on the package.  
1. Remove the blank panel covering the slot in which the module will be  
installed. All other slots must remain covered to ensure proper airflow  
and cooling.  
2. Install the module by sliding it into slots as shown in Figure 3-2.  
Ensure that the printed circuit board (PCB) is between the card guides,  
slides in straight, and engages the backplane connectors properly.  
3. Using a slotted screwdriver, tighten the top and bottom screws.  
TPRMI  
TPR  
Card  
Guides  
7C03 MMAC SmartSwitch  
3.3.2 Removing from the7C03 SmartSwitch  
The 7F06-02 Module inserted in the 7C03 MMAC SmartSwitch can  
be removed whenever necessary. Follow the steps below and refer  
to Figure 3-3 to remove the module.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION/REMOVAL  
Note: Before removing the 7F06-02 module, attach the wrist strap  
included with the SmartSwitch or SmartSwitch module by  
following the instructions printed on the package.  
1. Use a slotted screwdriver to loosen the two screws that secure the  
module to the chassis.  
2. Locate the two ejector tabs on the module (to the right of the screws on  
the top and bottom of the module).  
3. Simultaneously press down on the bottom ejector tab and up on the  
top ejector tab until the module ejects from the backplane.  
4. Grasp both ejector tabs and carefully slide the module out of the  
chassis.  
7X00  
PWR  
7F00  
7E03-24  
SN  
CPU  
SN  
MAC ADR  
A
F
D
SN  
P
D
I
1
A
B
S
B
Screws  
Ejector  
Tabs  
A
P
S
B
A
F
D
P
S
A
B
D
I
2
B
Figure 3-3. Removing the 7F06-02 Module from the 7C03 MMAC  
SmartSwitch  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION/REMOVAL  
3.3.3 Installing in the 7C04 or 7C04-R Workgroup  
SmartSwitch  
The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup  
SmartSwitch using the following steps and referring to the  
appropriate figure.  
Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for  
the 7X00 SmartSwitch Module.  
The bottom slot in the 7C04-R Workgroup SmartSwitch is  
reserved for the 7X00 SmartSwitch Module.  
Before installing the 7F06-02 module, attach the wrist strap  
included with the SmartSwitch or SmartSwitch module by  
following the instructions printed on the package.  
1. Remove the blank panel covering the slot in which the module will be  
installed. All other slots must remain covered to ensure proper airflow  
and cooling.  
2. Install the module by sliding it into slots as shown in the appropriate  
figure. Ensure that the printed circuit board (PCB) is between the card  
guides, slides in straight, and engages the backplane connectors  
properly.  
3. Using a slotted screwdriver, tighten the top and bottom screws.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION/REMOVAL  
1
2
SN  
3
4
Figure 3-4. Installing the 7F06-02 Module in the 7C04 Workgroup  
SmartSwitch  
FANS  
4
3
2
1
Figure 3-5. Installing the 7F06-02 Module in the 7C04-R Workgroup  
SmartSwitch  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION/REMOVAL  
3.3.4 Removing from the 7C04 or 7C04-R Workgroup  
SmartSwitch  
The 7F06-02 Module, inserted in the 7C04 or the 7C04-R  
Workgroup SmartSwitch, can be removed whenever necessary.  
Follow the steps below and refer to the appropriate figure to  
remove the module.  
Note: Before removing the 7F06-02 module, attach the wrist strap  
included with the SmartSwitch or SmartSwitch module by  
following the instructions printed on the package.  
1. Use a slotted screwdriver to loosen the two screws that secure the  
module to the chassis.  
2. Locate the two ejector tabs on the module (below the screws on the left  
and right end of the module).  
3. Simultaneously press left on the left ejector tab and right on the right  
ejector tab until the module ejects from the backplane.  
4. Grasp both ejector tabs and carefully slide the module out of the  
chassis.  
Screws  
1
2
3
4
Ejector Tabs  
Figure 3-6. Removing the 7F06-02 Module from the 7C04 Workgroup  
SmartSwitch  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION/REMOVAL  
Screws  
FANS  
4
SN  
3
2
1
Ejector Tabs  
Figure 3-7. Removing the 7F06-02 Module from the 7C04-R Workgroup  
SmartSwitch  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4  
TROUBLESHOOTING  
The 7F06-02 Module uses LANVIEW, Cabletron Systems built-in  
visual diagnostic and status monitoring system.  
With LANVIEW LEDs the status of each transmit and receive port  
on the 7F06-02 Module can be determined, at a glance. This section  
discusses the function and purpose of the LEDs on the 7F06-02  
Module.  
Figure 4-1 shows the LANVIEW LEDs of the 7F06-02 Module.  
7F06-02  
SP  
A Link Status  
A
Primary  
Ring  
B Link Status  
F
D
D
I
1
P
S
A
B
Secondary  
Ring  
B
Receive  
Transmit  
Figure 4-1. The LANVIEW LEDs  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TROUBLESHOOTING  
Table 4-1 indicates the state of the receive port.  
Table 4-1. Port Receive LEDs  
LED Color  
State  
Yellow (Flashing)  
Data activity (flashing to steady on  
indicates rate)  
Off  
No activity, port can be disabled or  
enabled  
Table 4-2 indicates the state of the transmit port.  
Table 4-2. Port Transmit LEDs  
LED Color  
State  
Green (Flashing)  
Data activity (flashing to steady on  
indicates rate)  
Off  
No activity, port can be disabled or  
enabled  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
TROUBLESHOOTING  
Table 4-3 indicates the state of the A/B Link LEDs.  
Table 4-3. Link LEDs  
A
p
S
B
State  
Green  
Green  
N/A  
N/A  
Off  
Green  
Green  
Ports Enabled & Active  
Green  
THRU A, MAC on Primary,  
Secondary Bypasses Board  
Green  
Green  
Green  
Green  
Green  
Green  
Off  
Yellow Green  
THRU A, MAC on Primary,  
No MAC on Secondary  
Green  
Green  
Green  
Green  
THRU B, MAC on Secondary,  
Primary Bypasses Board  
Yellow Green  
Yellow Off  
THRU B, MAC on Secondary,  
No MAC on Primary  
THRU, No MAC on Primary,  
Secondary Bypasses Board  
Off  
Yellow Green  
THRU, No MAC on  
Secondary, Primary Bypasses  
Board  
Green  
Green  
Green  
Red  
Yellow WRAP A, MAC on Primary  
Yellow Red  
Yellow WRAP A, No MAC on  
Primary  
Yellow Green  
Red  
Green  
Green  
Green  
Green  
Green  
WRAP B, MAC on Primary  
WRAP B, No MAC on Primary  
WRAP AB, MAC on Primary  
BYPASS Primary & Secondary  
TWISTED A-A, B-B  
Yellow Yellow Red  
Green  
Green  
Green  
Green  
Off  
Red  
Off  
Red  
Red  
Off  
Yellow Off  
Yellow PCM did not complete, Not  
Active  
Red Off  
Off  
Red  
Ports Disabled  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 5  
TECHNICAL SPECIFICATIONS  
This chapter includes the technical specifications for Cabletron  
Systems 7F06-02 module. Cabletron Systems reserves the right to  
change these specifications at any time without notice.  
5.1 STANDARDS  
IEEE 802.1D  
IEEE 802.3i 10BASE-T  
5.2 EMI  
The EMI requirements of:  
• FCC Part 15 Class A  
• EN 55022 Class A  
• VCCI Class I  
5.3 EMC  
The EMC requirements of:  
• EN 50082-1  
• IEC 801-2 ESD  
• IEC 801-3 Radiated susceptibility  
• IEC 801-4 EFT  
5.4 NETWORK INTERFACES  
Two FPIMs  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL SPECIFICATIONS  
5.5 SAFETY  
It is the responsibility of the person who sells the system to which  
the module will be a part to ensure that the total system meets  
allowed limits of conducted and radiated emissions.  
This equipment meets the safety requirements of:  
• UL 1950  
• CSA C22.2 No. 950  
• EN 60950  
• IEC 950  
5.6 SERVICE  
MTBF  
MTTR  
>200,000 hours  
<0.5 hour  
5.7 PHYSICAL  
5.7.1 Dimensions  
31.1D x 22.9 H x 3.1 W centimeters  
(12.3 D x 9.0 H x 1.2 W inches)  
5.7.2 Weight  
Unit:  
1.8 kgs. (4 lbs.)  
4.5 kgs. (10 lbs.)  
Shipping:  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Network Hardware 8x8 DVI D Matrix Switches User Manual
Black Box Surge Protector SP250A User Manual
Black Decker Vacuum Cleaner VE100K User Manual
Bosch Appliances Automobile Electronics 0 User Manual
Bosch Appliances Coffeemaker TKN68E75UC User Manual
Bosch Appliances Security Camera VG4 User Manual
Brother Sewing Machine NX 400Q User Manual
Bryan Boilers Boiler BE 210 W4T7 User Manual
Canon Camera Lens 4657A006 User Manual
Canon Network Card MA 52 User Manual