6E122-26, 6E132-25, 6E123-26 and 6E133-25
SmartSwitch 6000 Interface Modules
User’s Guide
Ethernet
Ethernet
Ethernet
Ethernet
6E122-26
6E123-26
6E132-25
6E133-25
COM
COM
COM
COM
CPU
CPU
CPU
CPU
1
3
2
4
1
3
2
4
1
3
2
4
1
3
2
4
5
7
9
6
8
5
7
9
6
8
5
7
9
6
8
5
7
9
6
8
10
10
10
10
11 12
11 12
11 12
11 12
13 14
13 14
13 14
13 14
15 16
15 16
15 16
15 16
17 18
17 18
17 18
17 18
19 20
19 20
19 20
19 20
21 22
21 22
21 22
21 22
23 24
23 24
23 24
23 24
25
25
26
26
9032076-05
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICE
Cabletron Systems reserves the right to make changes in specifications and other information
contained in this document without prior notice. The reader should in all cases consult Cabletron
Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT
NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR
THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH
DAMAGES.
1998 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved
Printed in the United States of America
Order Number: 9032076-05 August 1998
Cabletron Systems is a registered trademark and SmartSwitch is a trademark of Cabletron Systems,
Inc.
All other product names mentioned in this manual may be trademarks or registered trademarks of
their respective companies.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment uses, generates, and can radiate radio frequency energy and if not installed in
accordance with the operator’s manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user
will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
Printed on
Recycled Paper
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
VCCI NOTICE
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment,
radio disturbance may arise. When such trouble occurs, the user may be required to take corrective
actions.
CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT
IMPORTANT: Before utilizing this product, carefully read this License Agreement.
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”)
that sets forth your rights and obligations with respect to the Cabletron software program (the
“Program”) contained in this package. The Program may be contained in firmware, chips or other
media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME
BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND
THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT
AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED
PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
ii
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
CABLETRON SOFTWARE PROGRAM LICENSE
1.
LICENSE. You have the right to use only the one (1) copy of the Program provided in this
package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by the
Copyright Act of the United States or as authorized in writing by Cabletron.
2.
3.
OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the
Program.
APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws
and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and
venue of the New Hampshire courts.
EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY
1.
EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in
writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including
its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO
YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE
ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
2.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER
(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,
INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)
ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,
EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR
ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME
INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO
YOU.
UNITED STATES GOVERNMENT RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer
software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the
Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects
is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the
DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its
successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in
subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at
252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
DECLARATION OF CONFORMITY
Application of Council Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Cabletron Systems, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name: Mr. J. Solari
European Representative Address: Cabletron Systems Limited
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment: Networking Equipment, for use in a
Commercial or Light Industrial
Environment.
We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged
with this notice conforms to the above directives.
Manufacturer
Legal Representative in Europe
Mr. Ronald Fotino
Mr. J. Solari
___________________________________
___________________________________
Full Name
Full Name
Principal Compliance Engineer
Managing Director - E.M.E.A.
___________________________________
___________________________________
Title
Title
Rochester, NH, USA
Newbury, Berkshire, England
___________________________________
___________________________________
Location
Location
iv
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1
INTRODUCTION
1.3.8 Year 2000 Compliant...................................................... 1-6
1.6 Getting Help............................................................................... 1-10
1.7 Related Manuals........................................................................ 1-11
CHAPTER 2
2.1 SmartTrunk.................................................................................. 2-1
2.3 100BASE-TX Network................................................................. 2-2
CHAPTER 3
INSTALLATION
3.1 Required Tools ............................................................................ 3-1
3.2 Unpacking the 6E12X-26 and 6E13X-25..................................... 3-1
3.3 6E12X-26 and 6E13X-25 Options ............................................... 3-2
3.4 Installing the 6E12X-26 and 6E13X-25 Into the
6C105 Chassis ............................................................................ 3-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
3.5.1 Connecting UTP Cables to Ports 1 Through 24 of the
3.5.2 Connecting UTP Cables to Ports 1 Through 24 of the
3.6 Completing the Installation.........................................................3-14
CHAPTER 4
CHAPTER 5
5.1 Overview......................................................................................5-1
5.7.5 Entering a New Screen Refresh Time...........................5-20
5.7.6 Setting the Screen Lockout Time ..................................5-21
5.7.7 Setting the Operational Mode........................................5-22
5.8 SNMP Community Names Screen.............................................5-24
5.8.1 Establishing Community Names ...................................5-25
5.9 SNMP Traps Screen..................................................................5-27
5.9.1 Configuring the Trap Table............................................5-28
vi
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5.18.2 Setting the Age Time .................................................... 5-65
5.18.3 Setting (Enabling or Disabling) the Port Status ............ 5-65
5.19 Ethernet Full Duplex Configuration Screen ............................... 5-66
5.19.1 Setting the Operation Mode.......................................... 5-68
5.20 Module Specific Configuration Menu Screen ............................ 5-69
5.21 System Resources Screen........................................................ 5-72
5.21.1 Setting the Reset Peak Utilization ................................ 5-73
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
5.28.2 Using the Clear Counters Command ............................5-99
APPENDIX A
SPECIFICATIONS
A.1 Device Specifications.................................................................. A-1
A.2 Physical Properties ..................................................................... A-1
A.3 Environmental Requirements...................................................... A-1
A.4 Input/Output Ports....................................................................... A-2
A.5 COM Port Pinout Assignments ................................................... A-3
A.6 Regulatory Compliance............................................................... A-3
viii
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
APPENDIX B
B.1 FE-100TX ....................................................................................B-1
B.2 FE-100FX ....................................................................................B-2
B.3 FE-100F3.....................................................................................B-3
APPENDIX C
MODE SWITCH BANK SETTINGS AND
OPTIONAL INSTALLATIONS
C.1 Required Tools ............................................................................C-1
C.2 Setting the Mode Switch..............................................................C-1
C.3 Installing Optional Fast Ethernet Interface Modules....................C-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
x
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1
INTRODUCTION
Welcome to the Cabletron Systems 6E122-26, 6E132-25, 6E123-26 and
6E133-25 SmartSwitch 6000 Interface Modules User’s Guide. This
guide describes the 6E122-26, 6E132-25, 6E123-26 and 6E133-25
Interface Modules and provides information concerning network
requirements, installation, troubleshooting, and the use of Local
Management.
1.1
USING THIS GUIDE
Read through this guide completely to understand the interface module
features, capabilities, and Local Management functions. A general
working knowledge of Ethernet and IEEE 802.3 type data
communications networks and their physical layer components is helpful
when using these devices.
Unless noted differently, the information in this guide applies to
NOTE
referred to as either the “6E12X-26 and 6E13X-25” or the
“module(s)”.
1.2
This guide is organized as follows:
the features of the 6E12X-26 and 6E13X-25, provides instructions on
obtaining additional help and concludes with a list of related manuals.
Chapter 2, Network Requirements, explains the network requirements
to consider before installing the 6E12X-26 and 6E13X-25 into the 6C105
SmartSwitch 6000 chassis.
Chapter 3, Installation, provides instructions on how to install the
modules in the chassis and connect cables to the modules.
Chapter 4, Troubleshooting, details the 6E12X-26 and 6E13X-25
LANVIEW LEDs that enable you to quickly diagnose
network/operational problems.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
Management and use the Local Management screens to manage the
6E12X-26 and 6E13X-25 interface modules and the 6C105 chassis.
operating specifications, connector pinouts, environmental requirements,
and physical properties.
Appendix B, FE-100TX, FE-100FX and FE-100F3 Specifications,
contains information about FE-100TX pinouts and information
concerning cable types used with the FE-100FX and FE100-F3.
Appendix C, Mode Switch Bank Settings and Optional Installations,
describes how to install optional Fast Ethernet Interface Modules and how
to set the Mode Switches.
1.3
6E12X-26 AND 6E13X-25 OVERVIEW
The 6E12X-26 and 6E13X-25, shown in Figure 1-1, are interface
modules for Cabletron Systems 6C105 SmartSwitch 6000 chassis.
The 6E12X-26 and 6E13X-25 are high-speed network switch devices that
support 802.1D switching (bridging), 802.1Q switching, and Cabletron
Systems SecureFast Switching Virtual Network technology. Ports 25 and
26 of the 6E12X-26 support optional Fast Ethernet Interface Modules and
can provide uplinks to 100BASE-TX or 100BASE-FX Fast Ethernet
networks. The 6E13X-25 is capable of being equipped with a High Speed
Interface Module (HSIM) that provides for additional connectivity to
other high speed networking technologies such as Asychronous Transfer
Mode (ATM), Wide Area Networks (WANs) and Fiber Distributed Data
Interface (FDDI).
The 6E12X-26 and 6E13X-25 can be used to connect individual
high-bandwidth user devices, such as workstations, and to provide a
central switching point for multiple Ethernet segments using devices such
as Cabletron Systems HubSTACK or other third party stackable devices.
Figure 1-1 displays the 6E122-26 and 6E132-25. The
6E122-26 and the 6E123-26 are functionally identical, as are
NOTE
the 6E132-25 and the 6E133-25.The only difference being that
the 6E123-26 and 6E133-25 modules support RJ21 front panel
connections.
1-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6E12X-26 and 6E13X-25 Overview
Ethernet
Ethernet
6E122-26
6E132-25
COM Ports
COM
COM
System
LEDs
CPU
CPU
1
3
2
4
1
3
2
4
5
7
9
6
8
5
7
9
6
8
Port Status
LEDs
10
10
11 12
11 12
Network
Ports 1-24
Network
Ports 1-24
13 14
13 14
15 16
15 16
17 18
17 18
19 20
19 20
21 22
21 22
23 24
23 24
25
Fast Ethernet
Interface Module
Ports 25 and 26
HSIM Slot
26
207601
Figure 1-1 The 6E122-26 and 6E132-25
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
1.3.1
Connectivity
The 6E122-26 and 6E132-25 connect to Ethernet networks or
workstations through 24 RJ45 ports on the front panel. These ports
support UTP connections up to 100 meters. The ports are IEEE 802.3
10BASE-T compliant.
The 6E123-26 and 6E133-25 connect to Ethernet networks or
workstations through two RJ21 connectors on the front panel. These
connectors support 25 pair cable at lengths up to 100 meters. The ports
are IEEE 802.3 10BASE-T compliant.
The 6E12X-26 modules have two front panel slots (ports 25 and 26) for
optional Fast Ethernet Interface Modules to support an uplink to
100 Mbps Ethernet backbones or a high speed connection to a local
server.
The 6E13X-25 modules have one front panel slot for an optional High
Speed Interface Module to provide for additional connectivity to other
high speed networking technologies such as ATM, WANs and FDDI.
1.3.2
Full Duplex Switched Ethernet
Each switched Ethernet port supports full wire-speed Ethernet
communications and can be configured to operate in Full Duplex
Switched Ethernet mode, which provides up to 20 Mbps of bandwidth.
The optional Fast Ethernet Interface Modules for the 6E12X-26 can also
be configured to operate in Full Duplex Switched Ethernet mode, which
provides up to 200 Mbps of bandwidth.
1-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6E12X-26 and 6E13X-25 Overview
1.3.3
SmartTrunk
SmartTrunk, also referred to as SmartTrunking, is Cabletron Systems’
terminology for load balancing or load sharing. SmartTrunk technology
provides an easy-to-implement mechanism to group, or aggregate,
multiple links of any technology together to scale the backbone
bandwidth beyond the limitations of a single link. All links are
user-configurable so administrators can scale the backbone bandwidth by
adding SmartTrunk links. The SmartTrunk benefits are as follows:
•
•
•
All purchased bandwidth is used.
Distributed, resilient links increase reliability and performance.
Multiple technologies are supported within a single trunk for
maximum flexibility.
For more information about SmartTrunk, refer to the Cabletron Systems
SmartTrunk User’s Guide.
1.3.4
Management
Management of the 6E12X-26 and 6E13X-25 is accomplished using
Local Management tools or remote SNMP management stations. Local
Management is accessible through the RS232 COM port on the front
panel using a local VT100 terminal, or a remote VT100 terminal via a
modem connection, and in-band via a Telnet connection. In-band remote
management is possible through any SNMP compliant Network
Management Software.
1.3.5
Switching Options
The 6E12X-26 and 6E13X-25 provide 802.1D switching, 802.1Q
switching, or SecureFast Switching Virtual Network Services between all
of the front panel interfaces including Fast Ethernet Interface Modules
and High Speed Interface Modules (HSIMs).
SecureFast switching and 802.1Q switching allow for future migration to
Virtual Network technologies without requiring the replacement of
existing equipment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
1.3.6
Standards Compatibility
The 6E12X-26 and 6E13X-25 are fully compliant with the IEEE 802.3
standard. The optional Fast Ethernet Interface Modules are fully
compliant with the IEEE 802.3u standard. The 6E12X-26 and 6E13X-25
provide IEEE 802.1D Spanning Tree Algorithm (STA) support to enhance
the overall reliability of the network and protect against “loop”
conditions. The 6E12X-26 and 6E13X-25 support a wide variety of
industry standard MIBs including RFC 1213 (MIB II), RFC 1757
(RMON), RFC 1493 (Bridge MIB) and RFC 1354 (FIB MIB). A full suite
of Cabletron Systems Enterprise MIBs provide a wide array of statistical
information to enhance troubleshooting.
1.3.7
LANVIEW Diagnostic LEDs
LANVIEW diagnostic LEDs serve as an important troubleshooting aid by
providing an easy way to observe the status of individual ports and overall
network operations. Chapter 4 provides details about the 6E12X-26 and
6E13X-25 LANVIEW LEDs.
1.3.8
Year 2000 Compliant
The 6E12X-26 and 6E13X-25 have an internal clock that can maintain the
current time and date beyond the year 1999.
1.3.9
Runtime IP Address Discovery
This feature enables the modules to automatically accept an IP address
from a BootP server on the network into NVRAM without requiring a
user to enter an IP address through Local Management.
When the modules are connected to the network and powered up,
Runtime IP Address Discovery (RAD) checks the modules for an IP
address. If one has not yet been assigned (module and 6C105 chassis IP
address set to 0.0.0.0), RAD checks to see if any of the module interfaces
have a link. If so, RAD sends out Reverse Address Resolution Protocol
(RARP) and BootP requests to obtain an IP address from a RARP or
BootP server on the network.
The RAD requests start out at an interval of one second. The interval then
doubles after every transmission until an interval of 300 seconds is
reached. At this point, the interval remains at 300 seconds. The RAD
requests continue until an IP address is received from a RARP or BootP
server, or an IP address is entered using Local Management.
1-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6E12X-26 and 6E13X-25 Overview
1.3.10 Local Management Features
Local Management provides the tools that allow management of the
6E12X-26 and 6E13X-25, the Fast Ethernet Interface Modules, the High
Speed Interface Module (HSIM) and the 6C105 chassis. It also allows the
following tasks to be performed:
•
Manage any module installed in the 6C105 via a single terminal
connection.
•
Assign an IP address and subnet mask to the 6C105 chassis, 6E12X-26
and 6E13X-25.
•
•
•
Select a default gateway.
Designate workstations to receive SNMP traps from the 6E12X-26
and 6E13X-25 interface modules and the 6C105 chassis.
•
Configure module specific SNMP MIB objects including the IETF
Bridge MIB objects.
Chapter 5 provides detailed information about Local Management of the
6E12X-26 and 6E13X-25, the optional Fast Ethernet Interface Modules
and the 6C105 chassis. The associated High Speed Interface Module
user’s guide provides detailed information about Local Management of
the applicable HSIM.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
1.4
OPTIONAL FEATURES
Options for the 6E12X-26 and 6E13X-25 are Fast Ethernet Interface
Modules and High Speed Interface Modules, which add remote uplink
capability.
Cabletron Systems provides Fast Ethernet Interface Modules for the
6E12X-26 to support uplinks to 100 Mbps Ethernet backbones or high
speed connections to local servers. The Fast Ethernet Interface Modules
are listed in Table 1-1.
Table 1-1 Fast Ethernet Interface Modules
P/N
Description
Application
Supports Category 5 Unshielded Twisted Pair
(UTP) cabling with an impedance between 85
and 111 ohms.
Uses RJ45
connector
FE-100TX
Uses SC
connector
FE-100FX
FE-100F3
Supports multimode fiber optic cabling.
Supports single mode fiber optic cabling.
Uses SC
connector
Cabletron Systems provides High Speed Interface Modules for the
6E13X-25 to provide for additional connectivity to other high speed
networking technologies such as ATM, WANs and FDDI. The HSIMs
available for the 6E13X-25 are listed in the Release Notes.
1-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Document Conventions
1.5
DOCUMENT CONVENTIONS
The following conventions are used throughout this document:
Note symbol. Calls the reader’s attention to any item of
information that may be of special importance.
NOTE
Tip symbol. Conveys helpful hints concerning procedures or
actions.
TIP
Caution symbol. Contains information essential to avoid
damage to the equipment.
!
CAUTION
Electrical Hazard Warning symbol. Warns against an action
that could result in personal injury or death due to an electrical
hazard.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
1.6
GETTING HELP
For additional support related to this device or document, contact the
Cabletron Systems Global Call Center:
http://www.cabletron.com/
World Wide Web
For technical support, select Service and Support
Phone
(603) 332-9400
Internet mail
FTP
ftp://ftp.cabletron.com
anonymous
Login
Password
your email address
To send comments or suggestions concerning this document, contact the
Cabletron Systems Technical Writing Department via the following
Make sure to include the document Part Number in the email message.
Before calling the Cabletron Systems Global Call Center, have the
following information ready:
•
•
•
Your Cabletron Systems service contract number
A description of the failure
A description of any action(s) already taken to resolve the problem
(e.g., changing mode switches, rebooting the unit, etc.)
•
The serial and revision numbers of all involved Cabletron Systems
products in the network
•
•
•
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of trouble (if known)
The device history (i.e., have you returned the device before, is this a
recurring problem, etc.)
•
Any previous Return Material Authorization (RMA) numbers
1-10
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Related Manuals
1.7
RELATED MANUALS
The following manuals may help to set up, control, and manage the
6E12X-26 and 6E13X-25:
Cabletron Systems HSIM-A6DP User’s Guide
Cabletron Systems HSIM-F6 User’s Guide
Cabletron Systems HSIM-FE6 User’s Guide
Cabletron Systems HSIM-W6 User’s Guide
Cabletron Systems HSIM-W84 User’s Guide
Cabletron Systems HSIM-W87 User’s Guide
Cabletron Systems HSIM-G01/G09 User’s Guide
Cabletron Systems Ethernet Technology Guide
Cabletron Systems Cabling Guide
Cabletron Systems Port Based VLAN User’s Guide
Cabletron Systems SmartTrunk User’s Guide
These manuals can be obtained from the World Wide Web in Adobe
Acrobat Portable Document Format (PDF) at the following site:
http://www.cabletron.com/
All documentation for the Cabletron Systems SecureFast VLAN
Manager software is contained on the VLAN Manager
NOTE
CD-ROM.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
1-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
1-12
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 2
NETWORK REQUIREMENTS
Before installing the 6E12X-26 and 6E13X-25 or Fast Ethernet Interface
Modules (FE-100TX, FE-100FX, or FE-100F3), review the requirements
and specifications referred to in this chapter concerning the following:
•
•
•
•
SmartTrunk (Section 2.1)
10BASE-T Twisted Pair Network (Section 2.2)
100BASE-TX Twisted Pair Network (Section 2.3)
100BASE-FX Fiber Optic Network (Section 2.4)
The network installation must meet the guidelines to ensure satisfactory
performance of this equipment. Failure to follow the guidelines may
produce poor network performance.
The Cabletron Systems Cabling Guide and SmartTrunk User’s
Guide, referred to in the following sections, can be found on
NOTE
the Cabletron Systems World Wide Web
site: http://www.cabletron.com/
2.1
SmartTrunk
To connect the 6E12X-26 and 6E13X-25 to a network so it can take
advantage of the SmartTrunk feature, there are certain rules concerning
port connections and configurations that must be followed for proper
operation. Refer to the Cabletron Systems SmartTrunk User’s Guide for
additional information.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Network Requirements
2.2
10BASE-T NETWORK
When connecting a 10BASE-T segment to any of the 6E12X-26 and
6E13X-25 ports (Interfaces 1 through 24), ensure that the network meets
the Ethernet network requirements of the IEEE 802.3 standard for
10BASE-T. Refer to the Cabletron Systems Cabling Guide for details.
2.3
100BASE-TX NETWORK
The 6E12X-26, with an FE-100TX installed in ports 25 and 26, provides
an RJ45 connection that supports Category 5 UTP cabling with an
impedance between 85 and 111 ohms. The device at the other end of the
twisted pair segment must meet IEEE 802.3u 100BASE-TX Fast Ethernet
network requirements for the devices to operate at 100 Mbps. Refer to the
Cabletron Systems Cabling Guide for details.
The 6E12X-26 with an FE-100TX installed is capable of
operating at either 10 or 100 Mbps. The FE-100TX can
NOTE
automatically sense the speed of the other device and adjusts
its speed accordingly.
2.4
100BASE-FX FIBER OPTIC NETWORK
Ports 25 and 26 of the 6E12X-26 support the Cabletron Systems
FE-100FX and FE-100F3 fiber optic interface modules. The device at the
other end of the fiber optic segment must meet the 100BASE-FX Fast
Ethernet network requirements to operate at 100 Mbps. Refer to the
Cabletron Systems Cabling Guide for details.
Multimode Mode Fiber Optic Cable Length
The maximum multimode fiber optic cable length of a 100BASE-FX
segment is covered in the Cabletron Systems Cabling Guide.
Single Mode Fiber Cable Lengths
The maximum single mode fiber optic length of a 100BASE-FX segment
may be no more than 5 km between Data Terminal Equipment (DTE to
DTE) in half duplex mode or 20 km (DTE to DTE) in full duplex mode.
2-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 3
INSTALLATION
Only qualified personnel should install the 6E12X-26 and
6E13X-25.
This chapter covers the following items:
•
•
•
•
Required tools
Unpacking the 6E12X-26 and 6E13X-25
Installing the 6E12X-26 and 6E13X-25 into the 6C105 chassis
Connecting to the network
3.1
REQUIRED TOOLS
A Phillips screwdriver is required to install the optional Fast Ethernet
Interface Modules into the 6E12X-26.
3.2
UNPACKING THE 6E12X-26 AND 6E13X-25
1. Open the box and remove the packing material protecting the module.
2. Verify the contents of the carton as listed in Table 3-1.
Table 3-1 Contents of Shipping Carton
Item
Quantity
6E132-25, 6E122-26,
6E133-25 or
6E123-26
1
1
2
Release Notes
RJ21 Angle Adapter
(6E123-26 and
6E133-25 only)
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
3.3
6E12X-26 AND 6E13X-25 OPTIONS
Install any optional equipment before proceeding to
Section 3.4.
NOTE
If the 6E12X-26 is to be installed with an optional Fast Ethernet Interface
Module, refer to Appendix C for installation instructions. The installation
instructions for the HSIMs available for the 6E13X-25 are located in the
associated user’s guide.
3.4
INSTALLING THE 6E12X-26 AND 6E13X-25 INTO
THE 6C105 CHASSIS
Failure to observe static safety precautions could cause
damage to the 6E12X-26 and 6E13X-25. Follow static safety
handling rules and properly wear the antistatic wrist strap
provided with the 6C105 chassis.
!
CAUTION
Do not cut the non-conductive bag to remove the module.
Damage could result from sharp objects contacting the board
or components.
!
CAUTION
The 6E12X-26 and 6E13X-25 can be installed in any of the 5 slots that
are available. To install a module, proceed as follows:
1. Remove the blank panel covering the slot in which the module will be
installed. All other slots must remain covered to ensure proper airflow
and cooling. (Save the blank plate in the event you need to remove the
module.)
2. Carefully remove the module from the shipping box. (Save the box
and packing materials in the event the module must be reshipped.)
3. Locate the antistatic wrist strap shipped with the 6C105 chassis.
Attach the strap to your wrist and plug the cable from the antistatic
wrist strap into the ESD grounding receptacle at the upper right corner
of the 6C105.
3-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the 6E12X-26 and 6E13X-25 Into the 6C105 Chassis
4. Remove the module from the plastic bag. (Save the bag in the event
the module must be reshipped.) Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
5. Examine the module for damage. If any damage exists, DO NOT
install the module. Immediately contact the Cabletron Systems Global
Call Center.
To prevent damaging the backplane connectors in the following
step, take care that the module slides in straight and properly
engages the backplane connectors.
!
CAUTION
In the following step, ensure that the top plastic locking tab
lines up with the desired slot number located on the front panel
NOTE
of the chassis. Refer to Figure 3-1.
6. Locate the slot guides that line up with the number of the slot in which
the module will be installed. Install the module in the chassis by
aligning the module circuit card between the upper and lower metal
rail guides of the desired slot, sliding it into the chassis, and locking
down the top and bottom plastic locking tabs, as shown in Figure 3-1.
Take care that the module slides in straight and properly engages the
backplane connectors.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
Slot Number
Plastic Locking Tab
3
4
5
PS1
PS2
1
2
Ethernet
6E132-25
COM
CPU
1
3
2
4
5
7
9
6
8
10
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
Metal Back-Panel
Circuit Card
Card Guides
Plastic Locking Tab
207602
Figure 3-1 Installing an Interface Module
3-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to the Network
3.5
CONNECTING TO THE NETWORK
This section provides the procedures for connecting segments from the
network or other devices to the modules.
If the 6E12X-26 and 6E13X-25 are being installed in a network
using SmartTrunking, there are rules concerning the network
NOTE
cable and port configurations that must be followed for
SmartTrunking to operate properly. Before connecting the
cables refer to the Cabletron Systems SmartTrunk User’s
Guide shipped with the modules..
Ports 1 through 24 on the 6E122-26 and 6E132-25 have RJ45 connectors
for twisted pair connections. Ports 1 through 24 on the 6E123-26 and
6E133-25 have RJ21 connectors for twisted pair connections. Ports 25
and 26 of the 6E12X-26 support FE-100TX, FE-100FX, or FE-100F3
Fast Ethernet Interface Modules. The FE-100TX has an RJ45 connector
for a Category 5 UTP cable connection. The FE-100FX has an SC style
connector for a multimode fiber optic cable connection. The FE-100F3
Refer to Section 3.5.1 to make twisted pair connections to ports 1 through
Refer to Section 3.5.2 to make twisted pair connections to ports 1 through
24 of the 6E123-26 and 6E133-25.
Refer to Section 3.5.3 to make a Twisted Pair connection to an
FE-100TX.
Refer to Section 3.5.4 to make a fiber optic connection to an FE-100FX or
FE-100F3.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
3.5.1
Connecting UTP Cables to Ports 1 Through 24 of
the 6E122-26 and 6E132-25
Ports 1 through 24 of the 6E122-26 and 6E132-25 are 10BASE-T ports
with internal crossovers. When connecting a workstation, use a
straight-through cable. When connecting networking devices, such as
another bridge, repeater, or router, use a crossover cable.
Connect a twisted pair segment to the 6E122-26 and 6E132-25 as follows:
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. Connect the twisted pair segment to the 6E132-25 or 6E122-26 by
inserting the RJ45 connector on the twisted pair segment into the
desired RJ45 port (Ports 1 through 24) as shown in Figure 3-2.
.
5
7
9
6
8
10
11 12
13 14
15 16
RX (Receive)
LED
17 18
19 20
21 22
23 24
207603
Figure 3-2 6E122-26 and 6E132-25 Twisted Pair Connection
3-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to the Network
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a. Verify that the 10BASE-T device at the other end of the twisted
pair segment is ON and connected to the segment.
b. Verify that the RJ45 connectors on the twisted pair segment have
the proper pinouts (Figure 3-3) and check the cable for continuity.
TO
TO
10BASE-T Device Port
SmartSwitch RJ45 Port
RX+
RX–
RX+
RX–
1
2
1
2
NOTE:
RX+/RX– and TX+/TX–
must share a common
color pair.
TX+
TX+
TX–
3
6
3
6
RJ45 to RJ45
Figure 3-3 Cable Pinouts - (RJ45) Crossover Cable
c. Check that the twisted pair connection meets the dB loss and cable
specifications outlined in Chapter 2.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
4. Repeat steps 1 through 3, above, until all connections have been made.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
3.5.2
Connecting UTP Cables to Ports 1 Through 24 of
the 6E133-25 and 6E123-26
When facing the front panel of the 6E133-25 or 6E123-26, the upper
RJ21 is the connector for 10BASE-T ports 1 through 12. The lower RJ21
is for 10BASE-T ports 13 through 24. All 24 ports have internal
crossovers.
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. If using an RJ21 straight connector, plug it into the appropriate RJ21
port as shown in Figure 3-4 or, if using the RJ21 angle adapter
supplied with the device, insert the RJ21 angle adapter as shown in
Figure 3-5. The RJ21 angle adapter allows the cable to be inserted
without interfering with the proper attachment of the second
connector.
.
9
10
Screw Hole
11 12
Screw
1
13 14
24
15 16
RX (Receive)
LED
17 18
19 20
21 22
23 24
13
207603
Screw Hole
Screw
Figure 3-4 6E133-25 and 6E123-26 Twisted Pair Connection
3-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to the Network
9
10
Screw Hole
11 12
Screw
13 14
15 16
RX (Receive)
LED
17 18
19 20
21 22
23 24
207603
Screw Hole
Screw
Figure 3-5 Connection Using the RJ21 Angle Adapter
3. Tighten the two screws on the RJ21 connector or RJ21 angle adapter,
as applicable, to secure it to the module.
The cable pinouts for a 25 pair cable (RJ21) can be found in the
Cabletron Systems Cabling Guide. Refer to Section 1.7,
NOTE
Related Manuals, for details on how to obtain this document.
4. If using the RJ21 angle adapter, plug the 25 pair cable into the adapter
as shown in Figure 3-5.
5. Verify that a link exists by checking that the port RX LEDs are on
(flashing amber, blinking green, or solid green). If the RX LEDs are
off, perform the following steps until it is on:
a. Verify that the 10BASE-T device at the other end of the twisted
pair segment is ON and connected to the segment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
b. Verify that the RJ21 connectors on the twisted pair segment have
the proper pinouts and check the cable for continuity.
c. Check that the twisted pair connection meets the dB loss and cable
specifications outlined in Chapter 2.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
6. Repeat steps 1 through 4, above, until all connections have been made.
3.5.3
Connecting a Twisted Pair Segment to the
FE-100TX
An FE-100-TX installed in port 25 and/or 26 has an internal crossover
switch. When connecting a workstation, use a straight-through cable and
set the Fast Ethernet Interface Module crossover switch shown in
Figure 3-6 to the crossed over position marked with X. When connecting
straight-through cable and set the Fast Ethernet Interface Module
crossover switch shown in Figure 3-6 to the not crossed over position,
marked with =.
A schematic of a crossover cable is shown in Figure 3-6. If the wires do
not cross over, use the switch on the FE-100TX to internally cross over
the RJ45 port. Figure 3-6 shows how to properly set the FE-100TX
crossover switch.
Position X
(crossed over)
Position =
(not crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
5. NC
6. RX-
7. NC
8. NC
1. TX+
2. TX-
3. RX+
4. NC
x
=
10
100
FE-100TX
16651_05
Figure 3-6 FE-100TX Crossover Switch
3-10
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to the Network
Connect an FE-100TX to a twisted pair segment as follows:
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. Connect the twisted pair segment to the module by inserting the RJ45
connector on the twisted pair segment into the RJ45 port on the
module shown in Figure 3-6.
3. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a. Verify that the 100BASE-TX device at the other end of the twisted
pair segment is powered up.
b. Verify that the RJ45 connector on the twisted pair segment has the
proper pinouts.
c. Check the cable for continuity.
d. Make sure that the twisted pair connection meets dB loss and cable
specifications outlined in Section 2.3.
e. Confirm that the crossover switch is in the correct position.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
3.5.4
Connecting a Fiber Optic Segment to the
FE-100FX and FE-100F3
The FE-100FX and FE-100F3 have an SC style network port (see
Figure 3-7). Cabletron Systems supplies fiber optic cable that uses SC
style connectors that are keyed to ensure proper crossing over of the
transmit and receive fibers.
An odd number of crossovers (preferably one) must be
maintained between devices so that the transmit port of one
device is connected to the receive port of the other device and
vice versa.
!
CAUTION
If the fiber optic cable being used has SC style connectors that
do not resemble MIC style connectors, or has SC connectors
on one end and a different type on the other, such as ST
connectors, ensure that the proper crossing over occurs.
Fiber Optic Network Connection
1. Remove the protective plastic covers from the fiber optic ports on the
applicable port on the module and from the ends of the connectors.
The FE-100F3 uses Class 1 lasers. Do not use optical
instruments to view the laser output. The use of optical
instruments to view laser output increases eye hazard. When
viewing the output optical port, power must be removed from
the network adapter.
!
CAUTION
Do not touch the ends of the fiber optic strands, and do not let
the ends come in contact with dust, dirt, or other contaminants.
Contamination of the ends causes problems in data
transmissions. If the ends become contaminated, clean them
with alcohol using a soft, clean, lint-free cloth.
!
CAUTION
2. Insert one end of the SC connector into the FE-100FX or FE-100F3
installed in the 6E12X-26. See Figure 3-7.
3. At the other end of the fiber optic cable, attach the SC connector to the
other device.
3-12
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to the Network
25
RX LED
TX LED
F
E
-
0
F
X
26
Figure 3-7 FE-100FX and FE-100F3 Port
4. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off
and the TX LED is not blinking amber, perform the following steps
until it is on:
The port RX LED flashes green and amber during bootup.
NOTE
a. Check that the power is turned on for the device at the other end of
the link.
b. Verify proper crossing over of fiber strands between the
applicable port on the 6E12X-26 and the fiber optic device at the
other end of the fiber optic link segment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Installation
c. Verify that the fiber connection meets the dB loss specifications
outlined in Chapter 2.
If a link has not been established, contact the Cabletron Systems Global
Call Center. Refer to Section 1.6, Getting Help, for details.
3.6
COMPLETING THE INSTALLATION
The 6E12X-26 and 6E13X-25 are now ready to be set up through Local
Management. Refer to Chapter 5, Local Management, to configure the
modules and 6C105 chassis.
3-14
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4
TROUBLESHOOTING
This chapter provides information concerning the following:
•
•
•
Using the LANVIEW diagnostic and status monitoring system
Troubleshooting network and module operational problems
Using the RESET button
The four interface modules covered in this manual all share the
same LANVIEW LEDs.
NOTE
4.1
USING LANVIEW
The 6E12X-26 and 6E13X-25 use Cabletron Systems built-in visual
diagnostic and status monitoring system called LANVIEW. The
LANVIEW LEDs (Figure 4-1) allow quick observation of the network
status to aid in diagnosing network problems. Refer to Table 4-1 for a
description of the LEDs.
For a functional description of the LANVIEW LED on the optional Fast
Ethernet Interface Module (FE-100TX), refer to Section 4.2.
All LEDs for the High Speed Interface Module (HSIM) are located on the
HSIM and are described in the associated HSIM user’s guide.
The terms flashing, blinking, and solid used in the LED
definition tables of this chapter indicate the following:
NOTE
Flashing indicates an irregular LED pulse.
Blinking indicates a steady LED pulse.
Solid indicates a steady LED light. No pulsing.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Troubleshooting
Ethernet
6E122-26
COM
CPU
CPU LED
1
3
2
4
5
7
9
6
8
10
11 12
13 14
15 16
17 18
19 20
Receive (RX)
Transmit (TX)
21 22
23 24
25
26
207604
Figure 4-1 LANVIEW LEDs
4-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Using LANVIEW
Table 4-1 LANVIEW LEDs
State Recommended Action
Power up chassis.
LED
Color
Off
Power off.
Contact the Cabletron
Systems Global Call Center
(GCC).
Blinking. Hardware
failure has occurred.
Red
No action. If LED remains Red
for several minutes, contact
the Cabletron Systems GCC.
Solid. Resetting,
normal power up reset.
Contact the Cabletron
Systems GCC.
Amber
Blinking. Crippled.
CPU
No action. If LED remains
Amber for several minutes,
contact the Cabletron Systems
GCC.
Solid. Testing.
Green
Solid. Functional.
No action.
Amber
and
Green
Booting. Blinks amber
and green while
booting.
No action.
No link. No activity.
Port enabled or
disabled.
Off
No error.
No error.
No error.
Solid. Port enabled,
link, no activity.
Green
RX
Blinking. Port
disabled, link.
Flashing. Port
enabled, link, activity.
Amber
Red
No error.
Contact the Cabletron
Systems GCC for assistance.
Diagnostic failure.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Troubleshooting
Table 4-1 LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action
Should flash green every 2
seconds indicating BPDUs
being sent if STA is enabled
and there is a valid link. If STA
is enabled, and the LED does
not flash green, contact the
Cabletron Systems GCC.
Port enabled, and no
activity.
Off
Flashing. Indicates
activity. Rate indicates No action.
data rate.
TX
Green
Amber
Blinking. Port in
standby, link.
Port may be disabled due to
Spanning Tree.
Flashing. Indicates
collision rate.
No action.
Red
Solid. Diagnostic
Contact the Cabletron
Failure.
Systems GCC for assistance.
4.2
FE-100TX LED
The optional FE-100TX has one LED labeled 10/100. The 10/100 LED
together with the receive LED allows the user to determine the link status
and the operating speed of the Fast Ethernet Interface Module. The
10/100 LED and the Receive (RX) LED are shown in Figure 4-2.
Table 4-2 and Table 4-3 provide a functional description of the FE-100TX
LED when the RX LED is on or off, respectively.
4-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
FE-100TX LED
Receive
(RX) LED
10
100
LED
Figure 4-2 FE-100TX LED
A link exists if the associated port (port 25 or 26) Receive (RX)
LED is on.
NOTE
Table 4-2 FE-100TX LED Indications When the RX LED Is On
LED
Color
Description
Off
FE-100TX is operating at 10 Mbps.
FE-100TX is operating at 100 Mbps.
10/100
Green
No link exists if the associated port (port 25 or 26) Receive
(RX) LED is off.
NOTE
Table 4-3 FE-100TX LED Indications When the RX LED Is Off
LED
Color
Description
No link or no cable attached. FE-100TX
forced to 10 Mbps operation, or is
Off
manually set to “auto-negotiate” mode.
10/100
No link or no cable attached. FE-100TX is
forced to 100 Mbps operation.
Green
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Troubleshooting
4.3
TROUBLESHOOTING CHECKLIST
If the 6E12X-26 or 6E13X-25 is not working properly, refer to Table 4-4
for a checklist of possible problems, causes, and recommended actions to
resolve the problem.
Table 4-4 Troubleshooting Checklist
Problem
Possible Cause
Recommended Action
Check the proper connection
of the power cable and its
access to a live outlet.
Loss of power to the
6C105 chassis.
All LEDs are OFF.
6E13X-25 or 6E12X-26
not properly installed.
Check the installation.
Autobaud enabled. But
baud rate has not yet
been sensed.
Press ENTER (RETURN)
(may take up to four times).
No Local
Management
Password screen.
Terminal setup is not
correct.
Refer to Chapter 5 for proper
setup procedures.
Improper console cable
pinouts.
Refer to Appendix A for
proper console port pinouts.
Refer to Chapter 5
for Community Names Table
setup.
Improper Community
Names Table.
Cannot contact the
6E132-25 or
6E122-26 from
in-band
6E12X-26 or 6E13X-25
does not have an IP
address.
Refer to Chapter 5 for IP
address assignment
procedure.
management.
Port is disabled.
No link to device.
Enable port.
Check link to device.
Port(s) goes into
standby for no
apparent reason.
6E12X-26 or 6E13X-25
detects a looped
condition.
Review network design and
delete unnecessary loops.
User parameters (IP Mode switch (7), NVRAM
address, Device and Reset, was changed
Module name, etc.) sometime before either
are lost when the
6E12X-26 or
6E13X-25 is
cycling power or
pressing the RESET
button, causing the
Reenter the lost parameters
as necessary. Call the
Cabletron Systems GCC if
powered down or
the front panel
RESET button is
pressed.
user-entered parameters problem continues.
to reset to factory default
settings.
4-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the RESET Button
4.4
USING THE RESET BUTTON
The RESET button located near the upper plastic locking tab of the
module (refer to Figure 4-3) resets the 6E12X-26 and 6E13X-25
processor without affecting the NVRAM.
Pressing the RESET button resets the device, and all current
switching being performed by the device is halted. A module
downtime of up to two minutes will result from this action.
!
CAUTION
Ethernet
6E132-25
Reset Button
Figure 4-3 RESET Button
To reset the 6E12X-26 and 6E13X-25 processor, press and release the
RESET button. The module processor goes through a reset process of
approximately 20 seconds. Additional module downtime may be added as
the module reenters the network.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Troubleshooting
4-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 5
LOCAL MANAGEMENT
This chapter explains how to set up a management terminal to access
6E12X-26 and 6E13X-25 Local Management. It also explains how to use
the Local Management screens and commands.
The Local Management screens shown in this chapter are for
the 6E122-26. The 6E132-25, 6E133-25 and 6E123-26 share
NOTE
most of the following Local Management screens. All Local
Management functions specific to any of the interface modules
are preceded by a Note to alert the reader.
5.1
OVERVIEW
Local Management for the 6E12X-26 and 6E13X-25 consists of a series
of management screens that allow the management of the module, the
attached segments and the 6C105 chassis. The management screens allow
the user to perform the following tasks:
•
•
•
Manage any interface module in the chassis via a connection to a
single interface module.
Assign IP addresses and subnet masks to the 6E12X-26, 6E13X-25
and the 6C105 chassis.
Control access to the 6E12X-26, 6E13X-25 and the 6C105 chassis by
establishing community names.
•
•
Download a new image of operating software.
Designate which Network Management Workstations receive SNMP
traps from the 6E12X-26, 6E13X-25 and the 6C105 chassis.
•
•
•
•
•
Monitor the environmental status of the 6C105 chassis.
View switch, interface, and RMON statistics.
Assign ports to operate in standard or full duplex mode.
Enable trunking of ports to perform load sharing.
Configure the Fast Ethernet Interface Modules of the 6E12X-26 and
the HSIM of the 6E13X-25.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
There are three ways to access Local Management:
•
Locally using a VT type terminal connected to the COM port of the
6E13X-25 or 6E12X-26.
•
•
Remotely using a VT type terminal connected through a modem.
In-band through a Telnet connection.
5.2
LOCAL MANAGEMENT KEYBOARD
CONVENTIONS
All key names appear as capital letters in this manual. Table 5-1 explains
the keyboard conventions and the key functions that are used.
Table 5-1 Keyboard Conventions
Key
Function
These are selection keys that perform the same
Local Management function. For example, “Press
ENTER” means that you can press either ENTER
or RETURN, unless this manual specifically
instructs you otherwise.
ENTER Key
RETURN Key
This key allows an escape from a Local
Management screen without saving changes. For
example, “Press ESC twice” means the ESC key
must be pressed quickly two times.
ESCAPE (ESC) Key
These keys cycle through selections in some Local
Management fields. Use the SPACE bar to cycle
forward through selections and use BACKSPACE
to cycle backward through selections.
SPACE bar
BACKSPACE Key
These are navigation keys. Use the UP-ARROW,
DOWN-ARROW, LEFT-ARROW, and
RIGHT-ARROW keys to move the screen cursor.
For example, “Use the arrow keys” means to press
whichever arrow key moves the cursor to the
desired field on the Local Management screen.
Arrow Keys
This key decreases values from a Local
Management increment field. For example, “Press
[–]” means to press the minus sign key.
[–] Key
The DEL (Delete) key removes characters from a
Local Management field. For example, “Press DEL”
means to press the Delete key.
DEL Key
5-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Management Terminal Setup
5.3
MANAGEMENT TERMINAL SETUP
Use one of the following systems to access Local Management:
•
An IBM or compatible PC running a VT series emulation software
package
•
•
A Digital Equipment Corporation VT100 type terminal
A VT type terminal running emulation programs for the Digital
Equipment Corporation VT100 series
•
•
A remote VT100 type terminal via a modem connection
In-band via a Telnet connection
5.3.1
Console Cable Connection
Use the Console Cable Kit provided with the 6C105 chassis to attach the
management terminal to the COM port as shown in Figure 5-1.
Connect an IBM PC or compatible device, running the VT terminal
emulation, to the 6E12X-26 and 6E13X-25 as follows:
1. Connect the RJ45 connector at one end of the cable (supplied in the
kit) to the COM port on the 6E12X-26 and 6E13X-25.
2. Plug the RJ45 connector at the other end of the cable into the
RJ45-to-DB9 adapter (supplied in the kit).
3. Connect the RJ45-to-DB9 adapter to the PC communications port.
Ethernet
6E122-26
1
2
3
4
5
PS1
Ethernet
6E122-26
COM
RJ45 COM Port
CPU
1
3
2
4
COM
5
7
9
6
8
10
12
1
1
CPU
1
3
1
4
1
5
1
6
1
3
2
4
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
25
26
UTP Cable
With RJ45 Connectors
RJ45-to-DB9
PC Adapter
PC
Figure 5-1 Management Terminal Connection
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.3.2
Connecting an Uninterruptible Power Supply
(UPS)
If the 6C105 chassis is connected to an American Power Conversion
(APC) UPS for protection from a loss of power, a connection from the
COM port of a module to the UPS can be made to monitor the status of
the UPS. To use the COM port for this purpose, it must be reconfigured to
support the UPS application. This procedure is performed from the
General Configuration screen of the interface module. Section 5.15.11,
Configuring the COM Port, provides detailed instructions on
configuring the COM port for UPS applications. Refer to the UPS
documentation for details on how to access the status information.
Use the Console Cable Kit provided with the 6C105 chassis to attach the
UPS to the module COM port as shown in Figure 5-2.
Connect the UPS device to the COM port of the 6E12X-26 and 6E13X-25
as follows:
1. Connect the RJ45 connector at one end of the cable to the COM port
on the 6E12X-26 and 6E13X-25.
2. Plug the RJ45 connector at the other end of the cable into the
RJ45-to-DB9 male (UPS) adapter, Cabletron Systems Part No.
9372066.
3. Connect the RJ45-to-DB9 male (UPS) adapter to the female DB9 port
on the rear of the UPS device (refer to the particular UPS device’s user
instructions for more specific information about the monitoring
connection).
Ethernet
6E122-26
1
2
3
4
5
PS1
PS2
Ethernet
6E122-26
COM
CPU
RJ45 COM Port
1
3
2
4
5
7
9
6
8
COM
10
12
1
1
CPU
1
3
1
4
1
5
1
6
1
7
1
8
1
3
2
4
1
9
2
0
2
1
2
2
2
3
2
4
25
DB9 Port
26
UPS Device
UTP Cable
With RJ45 Connectors
RJ45-to-DB9
UPS Adapter
196051
Figure 5-2 Uninterruptible Power Supply (UPS)
5-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Management Terminal Setup
5.3.3
Management Terminal Setup Parameters
Table 5-2 lists the setup parameters for the local management terminal.
Table 5-2 VT Terminal Setup
Display Setup Menu
Columns ->
Controls ->
Auto Wrap ->
Scroll ->
80 Columns
Interpret Controls
No Auto Wrap
Jump Scroll
Text Cursor ->
Cursor Style ->
Cursor
Underline Cursor Style
General Setup Menu
Mode ->
VT100, 7 Bit Controls
VT100ID
Normal Cursor Keys
UPSS DEC Supplemental
ID number ->
Cursor Keys ->
Power Supply ->
Communications Setup Menu
Transmit ->
Receive ->
XOFF ->
2400, 4800, 9600, 19200
Receive=Transmit
XOFF at 64
Bits ->
8 bits
Parity ->
No Parity
Stop Bit ->
Local Echo ->
Port ->
Transmit ->
Auto Answerback ->
1 Stop Bit
No Local Echo
DEC-423, Data Leads Only
Limited Transmit
No Auto Answerback
Keyboard Setup Menu
Keys ->
Auto Repeat ->
Keyclick ->
Typewriter Keys
any option
any option
Margin Bell ->
Warning Bell ->
Margin Bell
Warning Bell
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.3.4
Once the module or chassis has a valid IP address, the user can establish a
Telnet session with Local Management from any TCP/IP based node on
the network. Telnet connections to the 6E12X-26 and 6E13X-25 require
the community name passwords assigned at the SNMP Community
Names screen of either the 6C105 chassis, or the module. For additional
information about community names, refer to Section 5.8, SNMP
Community Names Screen. Refer to the instructions included with the
Telnet application for information about establishing a Telnet session.
5-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Local Management
5.4
ACCESSING LOCAL MANAGEMENT
Access to Local Management is controlled through the Password screen,
Figure 5-3. Whenever a connection is made to the 6E12X-26 and
6E13X-25 the Password screen displays. Before continuing, the user must
enter a password which is compared to the previously stored passwords.
change passwords refer to Section 5.8. The following steps describe the
procedure to access Local Management.
1. Turn on the terminal. Press ENTER (this may take up to four times,
because the COM port of the 6E12X-26 and 6E13X-25 auto-senses the
baud rate of the terminal) until the 6C105 Local Management
Password screen, Figure 5-3, displays.
Event Message Line
6C105 LOCAL MANAGEMENT
CABLETRON Systems, Incorporated
P.O.Box 5005
Rochester, NH 03866-5005 USA
(603) 332-9400
(c) Copyright CABLETRON Systems, Inc, 1997
Enter Password:
1960_12
Figure 5-3 Local Management Password Screen
2. Enter the Password and press ENTER. The default Super-User access
password is “public” or press ENTER.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
The User’s password is one of the community names specified
NOTE
in the SNMP Community Names screen. Access to certain
Local Management capabilities depends on the degree of
access accorded that community name. Refer to Section 5.8.
•
•
•
If an invalid password is entered, the terminal beeps and the cursor
returns to the beginning of the password entry field.
Entering a valid password causes the associated access level to display
at the bottom of the screen and the Main Menu screen to appear.
If no activity occurs for several minutes, the Password screen
reappears and the session ends.
5.4.1
Navigating Local Management Screens
The 6E12X-26 and 6E13X-25 Local Management application consists of
a series of menu screens. Navigate through Local Management by
selecting items from the menu screens.
The 6E12X-26 and 6E13X-25 support three modes of switch operation.
The switching modes are as follows:
•
•
•
802.1D SWITCHING, (traditional switching)
802.1Q SWITCHING, (802.1Q port based VLANs)
SECURE FAST VLAN, (Cabletron Systems SecureFast Switching)
which screens are supported in each of the three available
switching modes.
NOTE
The switch operational mode may be set in either the Chassis
Configuration screen (Section 5.7), or the General Configuration screen
of the module (Section 5.15). Depending on the Operational Mode set for
the module, the hierarchy of Local Management screens differs as shown
in Figure 5-4, Figure 5-7, and Figure 5-8. Refer to the appropriate figure
that relates to the Operational Mode that will be set for the module to see
the applicable Local Management screen hierarchy.
5-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Local Management
\
General Configuration
Chassis
Menu
SNMP Community Names
SNMP Traps
Chassis Environmental
Port Redirect Function
Password
Module
Configuration
Menu
General Configuration
SNMP Community Names
SNMP Traps
Main
Menu
Switch Configuration
Ethernet Full Duplex
Configuration
SmartTrunk Configuration
System
Resources
Module Specific
Configuration Menu
Module
Menu
Fast
High Speed
Interface
Configuration
Ethernet
Switch Statistics
HSIM
Module
Statistics
Menu
Interface Statistics
Flash Download
Port Redirect
Function
RMON Statistics
Broadcast
Supression
Network Tools
Figure 5-4 802.1D Switching Mode, LM Screen Hierarchy
General Configuration
Chassis
SNMP Community Names
SNMP Traps
Menu
Chassis Environmental
802.1Q VLAN Configuration
Password
Module
Configuration
Menu
General Configuration
SNMP Community Names
SNMP Traps
Main
Menu
Switch Configuration
Ethernet Full Duplex
Configuration
SmartTrunk Configuration
System
Resources
Module Specific
Configuration Menu
Module
Menu
Fast
High Speed
Interface
Configuration
Ethernet
Switch Statistics
HSIM
Module
Statistics
Menu
Interface Statistics
Flash Download
RMON Statistics
Broadcast
Supression
Network Tools
802.1Q VLAN
Configuration
Figure 5-5 802.1Q Switching Mode, LM Screen Hierarchy
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
General Configuration
Chassis
Menu
SNMP Community Names
SNMP Traps
Chassis Environmental
Password
Module
Configuration
Menu
General Configuration
SNMP Community Names
SNMP Traps
Main
Menu
Ethernet Full Duplex
Configuration
System
Resources
Module Specific
Configuration Menu
Module
Menu
Fast
High Speed
Interface
Configuration
Ethernet
HSIM
Module
Statistics
Menu
Interface Statistics
RMON Statistics
Flash Download
Network Tools
Figure 5-6 SecureFast VLAN Mode, LM Screen Hierarchy
5.4.2
Selecting Local Management Menu Screen Items
Select items on a menu screen by performing the following steps:
1. Use the arrow keys to highlight a menu item.
2. Press ENTER. The selected menu item displays on the screen.
5.4.3
Exiting Local Management Screens
There are two ways to exit Local Management (LM).
Using the EXIT Command
To exit an LM screen using the EXIT command, proceed as follows:
1. Use the arrow keys to highlight the EXIT command at the bottom of
the Local Management screen.
2. Press ENTER. The Password screen displays and the session ends.
5-10
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Local Management
Using the RETURN Command
1. Use the arrow keys to highlight the RETURN command at the bottom
of the Local Management screen.
2. Press ENTER. The previous screen in the Local Management
hierarchy displays.
The user can also exit Local Management screens by pressing
ESC twice. This exit method does not warn about unsaved
NOTE
changes and all unsaved changes will be lost.
3. Exit from 6E12X-26 and 6E13X-25 Local Management by repeating
steps 1 and 2 until the Main Menu screen displays.
4. Use the arrow keys to highlight the RETURN command at the bottom
of the Main Menu screen.
5. Press ENTER. The Password screen displays and the session ends.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.5
THE MAIN MENU SCREEN
The Main Menu screen is the access point for all Local Management
screens for the module and the 6C105 chassis. Figure 5-7 shows the Main
Menu screen.
Event Message Line
6C105 LOCAL MANAGEMENT
Main Menu
CHASSIS
MODULES
EXIT
RETURN
1960_91
Figure 5-7 Main Menu Screen
The following explains each Main Menu screen item as shown in
Figure 5-7:
CHASSIS
shown in Figure 5-8, that is used to configure the 6C105 chassis, access
current chassis power supply and environmental status, and to configure
IEEE 802.1Q VLANs.
Access the Chassis Configuration screen by using the arrow keys to
highlight the CHASSIS menu item and pressing ENTER. The Chassis
Configuration screen displays. Proceed to Section 5.6.
5-12
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Menu Screen
MODULES
The MODULES menu item provides access to the Module Selection
screen that is used to select individual modules in the chassis for
management purposes.
Access the Module Selection screen by using the arrow keys to highlight
the MODULES menu item and pressing ENTER. The Module Selection
screen displays. Proceed to Section 5.12.
5.6
CHASSIS MENU SCREEN
The Chassis Menu screen, Figure 5-8, provides access to Local
Management screens that allow you to configure and monitor operating
parameters, modify SNMP community names, set SNMP traps, monitor
the 6C105 environmental status, perform port redirect functions, and to
configure the 6C105 for IEEE 802.1Q operation.
6C105 LOCAL MANAGEMENT
Chassis Menu
CHASSIS CONFIGURATION
SNMP COMMUNITY NAMES
SNMP TRAPS
CHASSIS ENVIRONMENTAL
PORT REDIRECT FUNCTION
802.1Q VLAN CONFIGURATION
EXIT
RETURN
2269_99
Figure 5-8 Chassis Menu Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
The following briefly explains each screen accessible from the Chassis
Menu screen.
CHASSIS CONFIGURATION
The Chassis Configuration screen allows the user to configure operating
parameters for the 6C105 chassis. For details, refer to Section 5.7.
SNMP COMMUNITY NAMES
The SNMP Community Names screen allows the user to enter new,
change, or review the community names used as access passwords for
device management operation. Access is limited based on the password
level of the user. For details, refer to Section 5.8.
SNMP TRAPS
The SNMP Traps screen provides display and configuration access to the
table of IP addresses used for trap destinations and associated community
names. For details, refer to Section 5.9.
CHASSIS ENVIRONMENTAL
The Chassis Environmental screen provides access to chassis power
supply status, power supply redundancy status and chassis fan tray status.
For details, refer to Section 5.10.
PORT REDIRECT FUNCTION
The Port Redirect Function screen allows the user to redirect traffic from
one or multiple modules and ports in the chassis to a specific destination
802.1Q VLAN CONFIGURATION
This menu item will only display if one or more modules installed the
chassis have been configured to operate as IEEE 802.1Q switches. When
selected, this menu item opens the VLAN Main Menu screen. For details,
refer to the Cabletron Systems Port Based VLAN User’s Guide.
Section 5.7.7, Setting the Operational Mode, describes how to
configure the modules to function as 802.1Q switches.
5-14
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Configuration Screen
5.7
CHASSIS CONFIGURATION SCREEN
chassis date and time, IP address and Subnet Mask, the operational mode
of all modules installed in the chassis, and to view the chassis uptime.
Access the Chassis Configuration screen from the Chassis Menu screen
by using the arrow keys to highlight the CHASSIS CONFIGURATION
menu item and pressing ENTER. The Chassis Configuration screen,
Figure 5-9, displays.
Event Message Line
6C105 LOCAL MANAGEMENT
Chassis Configuration
MAC Address:
IP Address:
00-00-ID-00-00-00
000.000.000.000
000.000.000.000
Chassis Date:
10/11/97
14:23:00
30 sec.
15 min.
Chassis Time:
Subnet Mask:
Screen Refresh Time:
Screen Lockout Time:
Chassis Uptime XX D XX H XX M
Operational Mode: [802.1D SWITCHING]
SAVE
EXIT
RETURN
1960_98
Figure 5-9 Chassis Configuration Screen
The following briefly explains each Chassis Configuration screen field:
MAC Address (Read-Only)
Displays the base physical address of the chassis.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
IP Address (Modifiable)
This field allows the IP address to be set for the 6C105 chassis. If an IP
address is assigned to the 6C105 chassis all the interface modules
installed in the chassis can be managed via this IP address, eliminating the
need to assign an IP address to each interface module. To set the IP
address, refer to Section 5.7.1.
Subnet Mask (Modifiable)
When a valid IP address is assigned, the Subnet Mask field
automatically enters the default mask that corresponds with
NOTE
class of IP entered in the IP Address field. Some firmware
revisions do support changing the chassis subnet mask from
the default value. Refer to your Release Notes to ensure that
the Subnet Mask is a modifiable field.
Displays the subnet mask for the chassis. A subnet mask “masks out” the
network bits of the IP address by setting the bits in the mask to 1 when the
network treats the corresponding bits in the IP address as part of the
network or subnetwork address, or to 0 if the corresponding bit identifies
the host. The 6C105 chassis automatically uses the default subnet mask
that corresponds to the IP class that was entered in the IP address field.
subnet mask from the default value.
Chassis Date (Modifiable)
Contains a value that the chassis recognizes as the current date. When the
chassis date is modified and saved all interface modules installed in the
chassis are set to this date. To set a new chassis date, refer to
Section 5.7.3.
Chassis Time (Modifiable)
Contains a value that the chassis recognizes as the current time. When the
chassis time is modified and saved, all interface modules installed in the
chassis are set to this time. To enter a new time, refer to Section 5.7.4.
Screen Refresh Time (Modifiable)
Contains the rate at which the screens are updated. This setting
determines how frequently (in seconds) information is updated on the
screen. To enter a new update time, refer to Section 5.7.5.
5-16
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Configuration Screen
Screen Lockout Time (Modifiable)
application displays a module’s screen while awaiting input or action
from a user. For example, if the number 5 is entered in this field, the user
has up to five minutes to respond to each of the specified module’s Local
Management screens. In this example, after five minutes of “idleness” (no
input or action), the terminal “beeps” five times, the Local Management
application terminates the session, and the display returns to the Password
screen. To enter a new lockout time, refer to Section 5.7.6.
Chassis Uptime (Read-Only)
Displays the total time the chassis has been operating. The chassis uptime
is based on which interface module installed in the chassis has been
operating for the longest period of time.
Operational Mode (Toggle)
This field allows the user to set all the modules in the chassis to operate as
traditional switches (802.1D SWITCHING option), or as IEEE 802.1Q
switches (802.1Q SWITCHING option).
In 802.1D SWITCHING mode, the 24 ports located on the front panel,
and each Fast Ethernet Interface Module, and HSIM port(s) are bridged to
each other.
When the operational mode is set to 802.1Q SWITCHING, the 6E12X-26
and 6E13X-25 act as IEEE 802.1Q switches. The modules are able to
increase their switching functionality by creating and maintaining port
based Virtual LANs (VLANs).
For details on how to select the Operational Mode, refer to Section 5.7.7.
5.7.1
Setting the IP Address
To set the IP address, perform the following steps:
1. Use the arrow keys to highlight the IP Address field.
2. Enter the IP address into this field using Decimal Dotted Notation
(DDN) format.
For example: 134.141.79.120
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-17
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
3. Press ENTER. If the IP address is a valid format, the cursor returns to
the beginning of the IP address field. If the entry is not valid, the Event
Message Line displays “INVALID IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The “SAVED OK” message displays indicating that the
changes have been saved to memory.
5.7.2
Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6C105 is located on a separate subnet, the subnet mask for the 6C105
must be changed from its default.
When a valid IP address is assigned, the Subnet Mask field
automatically enters the default mask that corresponds with
NOTE
class of IP entered in the IP Address field. Some firmware
revisions do support changing the chassis subnet mask from
the default value. Refer to your Release Notes to ensure that
the Subnet Mask is a modifiable field.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
3. Press ENTER. If the subnet mask is valid, the cursor returns to the
beginning of the Subnet Mask field. If the entry is not valid, the Event
Message Line displays “INVALID SUBNET MASK OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the Subnet Mask field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The changes are saved to memory.
5-18
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Configuration Screen
5.7.3
Setting the Chassis Date
The 6C105 is year 2000 compliant, so the Chassis Date may be set
beyond the year 1999. To set the chassis date, perform the following
steps:
1. Use the arrow keys to highlight the Chassis Date field.
2. Enter the date in an MM/DD/YYYY format.
It is not necessary to add separators between month, day, and
year numbers. For example, to set the date to 03/17/1997, type
NOTE
“03171997” in the Chassis Date field.
3. Press ENTER to set the system calendar to the date in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the date entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value, but it does refresh the
Chassis Date field with the previous value.
Upon saving the new chassis date, all interface modules
installed in the chassis recognize the new value as the current
NOTE
date.
5.7.4
Setting the Chassis Time
To set the chassis clock, perform the following steps:
1. Use the arrow keys to highlight the Chassis Time field.
2. Enter the time in a 24-hour format, HH:MM:SS.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
When entering the time in the system time field, separators
NOTE
between hours, minutes, and seconds do not need to be added
as long as each entry uses two numeric characters. For
example, to set the time to 6:45 A.M., type “064500” in the
Chassis Time field.
3. Press ENTER to set the system clock to the time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value and refreshes the Chassis
Time field with the previous value.
Upon saving the new chassis time, all interface modules
installed in the chassis recognize the new value as the current
NOTE
time.
5.7.5
Entering a New Screen Refresh Time
The screen refresh time is set from 3 to 99 seconds with a default of 3
seconds. To set a new screen refresh time, perform the following steps:
1. Use the arrow keys to highlight the Screen Refresh Time field.
2. Enter a number from 3 to 99.
3. Press ENTER to set the refresh time to the time entered in the input
field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 3 to 99 seconds range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Refresh Time field with the previous value.
5-20
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Configuration Screen
5.7.6
Setting the Screen Lockout Time
The screen lockout time can be set from 1 to 30 minutes with a default of
15 minutes. To set a new lockout time, perform the following steps:
1. Use the arrow keys to highlight the Screen Lockout field.
2. Enter a number from 1 to 30.
3. Press ENTER to set the lockout time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.7.7
Setting the Operational Mode
To set the Operational Mode, proceed as follows:
1. Use arrow keys to highlight the Operational Mode field.
2. Press the SPACE bar to step to the appropriate operation mode,
(802.1D SWITCHING or 802.1Q SWITCHING).
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER. The following warning screen displays:
WARNING!
YOU HAVE ELECTED TO SAVE THE OPERATIONAL MODE FOR
THE WHOLE CHASSIS. THIS WILL CAUSE ALL OF THE
BOARDS IN THE CHASSIS TO REBOOT.
ARE YOU SURE YOU WANT TO SAVE THE NEW OPERATIONAL MODE
YES
NO
1666
Figure 5-10 Operational Mode Warning Screen
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved, and all the modules installed in the chassis
reboot.
5-22
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Configuration Screen
If the 6E12X-26 and 6E13X-25 have been set to 802.1Q
configure the devices for this type of operation.
NOTE
The Operational Mode field in the Chassis Configuration
screen does not support the SECURE FASTVLAN operational
mode. For the modules to function as SecureFast switches,
they must have a unique IP addresses, and be configured to
act as Standalone devices in terms of Local Management via
the 6C105 chassis. Section 5.15.9 provides additional
instructions and rules that must be met before configuring the
modules as SecureFast switches.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.8
SNMP COMMUNITY NAMES SCREEN
The SNMP Community Names menu item allows the user to set Local
Management community names. Community names act as passwords to
Local/Remote Management and provide security access to the 6C105.
Access to the 6C105 is controlled by enacting any of three different levels
of security authorization (read-only, read-write, and super-user).
Super-User access gives the user full management privileges,
allows existing passwords to be changed, and all modifiable
NOTE
MIB objects for the Cabletron Container MIB and Internet
MIB-II to be edited.
Access the SNMP Community Names screen from the Chassis Menu
screen by using the arrow keys to highlight the SNMP COMMUNITY
NAMES menu item and pressing ENTER. The SNMP Community
Names screen, Figure 5-11, displays.
Event Message Line
6C105 LOCAL MANAGEMENT
SNMP Community Names
Community Name
public
Access Policy
read-only
public
read-write
public
super-user
SAVE
EXIT
RETURN
1960_97
Figure 5-11 SNMP Community Names Screen
5-24
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Community Names Screen
The following explains each SNMP Community Names screen field:
Community Name (Modifiable)
Displays the user-defined name through which a user accesses 6C105
management. Any community name assigned here acts as a password to
Local/Remote Management.
Access Policy (Read-Only)
Indicates the access accorded each community name. Possible selections
are as follows:
read-only
read-write
super-user
This community name allows read-only access
to the 6C105 MIB objects, and excludes access
to security-protected fields of read-write or
super-user authorization.
This community name allows read and write
access to the 6C105 MIB objects, excluding
security protected fields for super-user access
only.
This community name permits read-write
access to the 6C105 MIB objects and allows the
user to change all modifiable parameters
including community names, IP addresses,
traps, and SNMP objects.
5.8.1
Establishing Community Names
The password used to access Local Management at the Password screen
must have Super-User access in order to view and edit the SNMP
Community Names screen. Using a password with read-only or
read-write access does not allow the user to view or edit the SNMP
Community Names screen.
Any community name assigned in the SNMP Community
Names screen is a password to its corresponding level of
NOTE
access to Local Management. The community name assigned
Super-User access is the only one that gives the user complete
access to Local Management.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
All passwords assigned in the 6C105 SNMP Community
NOTE
Names screen allow access to both 6C105 Local Management
screens, and the Local Management screens of the interface
modules that are installed in the chassis. To configure the
interface module to not allow access to 6C105 Local
Management screens refer to Section 5.16.
To establish community names, proceed as follows:
1. Use the arrow keys to highlight the Community Name field adjacent
to the selected access level.
2. Enter the password in the field (maximum 31 characters).
3. Press ENTER.
4. Repeat steps 1 through 3 to modify the other community names.
5. Use the arrow keys to highlight SAVE at the bottom of the screen and
press ENTER. The message “SAVED OK” displays. The community
names are saved to memory and their access modes implemented.
5-26
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Traps Screen
5.9
SNMP TRAPS SCREEN
Since the 6C105 is an SNMP compliant device, it can send messages to
multiple Network Management Stations to alert users of status changes.
The SNMP Traps screen is shown in Figure 5-12.
Access the SNMP Traps screen from the Chassis Menu screen by using
the arrow keys to highlight the SNMP TRAPS menu item and pressing
ENTER. The SNMP Traps screen displays.
Event Message Line
6C105 LOCAL MANAGEMENT
Chassis SNMP Traps
Trap Destination
0.0.0.0
Trap Community Name
public
Enable Traps
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
0.0.0.0
public
[YES]
SAVE
EXIT
RETURN
1960_96
Figure 5-12 The SNMP Traps Screen
The following explains each field of the SNMP Traps screen.
Trap Destination (Modifiable)
Indicates the IP address of the workstation to receive trap alarms. Up to
eight different destinations can be defined.
Trap Community Name (Modifiable)
Displays the Community Name included in the trap message sent to the
Network Management Station with the associated IP address.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-27
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Enable Traps (Toggle)
Enables transmission of the traps to the network management station with
the associated IP address. This field toggles between [YES] and [NO].
5.9.1
Configuring the Trap Table
To configure the Trap table, proceed as follows:
1. Using the arrow keys, highlight the appropriate Trap Destination
field.
2. Enter the IP Address of the workstation that is to receive traps. IP
address entries must follow the DDN format.
For example: 134.141.79.121
3. Press ENTER. If an invalid entry is entered “INVALID IP
ENTERED” is displayed in the Event Message Line.
4. Using the arrow keys, highlight the Trap Community Name field.
Enter the community name.
5. Press ENTER.
6. Using the arrow keys, highlight the Enable Traps field. Press the
SPACE bar to choose either [YES] (send alarms from the chassis to
the workstation), or [NO] (prevent alarms from being sent).
7. Using the arrow keys, highlight the SAVE command and press
ENTER. The message “SAVED OK” displays on the screen.
Exiting without saving causes a “NOT SAVED?” message to
appear above the SAVE command. Edits will be lost if they are
NOTE
not saved before exiting.
The designated workstations now receive traps from the 6C105.
5-28
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis Environmental Screen
5.10 CHASSIS ENVIRONMENTAL SCREEN
The Chassis Environmental menu item allows the user to view chassis
environmental information.
Access the Chassis Environmental Information screen from the Chassis
Menu screen by using the arrow keys to highlight the CHASSIS
ENVIRONMENTAL menu item and pressing ENTER. The Chassis
Environmental Information screen, Figure 5-13, displays.
6C105 LOCAL MANAGEMENT
Chassis Environmental Information
Chassis Power Redundancy
Power Supply #1 Status
Power Supply #2 Status
Chassis Fan Status
Not Available
Normal
Not Installed
Normal
EXIT
RETURN
1960_94
Figure 5-13 Chassis Environmental Information Screen
The following describes each of the Chassis Environmental Information
screen fields.
Chassis Power Redundancy (Read-Only)
Displays the current redundancy status of the 6C105 power supplies. This
field will read either “Available” or “Not Available”.
Power Supply #X Status (Read-Only)
Displays the current status of power supplies 1 and 2 for the 6C105. This
field will read either “Normal”, “Fault”, or “Not Installed”.
Chassis Fan Status (Read-Only)
Displays the current status of the 6C105 fan tray. This field will read
either “Normal”, “Fault”, or “Not Installed”.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-29
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.11 PORT REDIRECT FUNCTION SCREEN
The Port Redirect Function screen may not be available
depending on the operational mode that has been set for the
NOTE
chassis. Refer to your Release Notes to see what operational
modes support the Port Redirect Function. Refer to
Section 5.7.7, Setting the Operational Mode, for instructions
on configuring the operational mode of all the modules installed
in the chassis.
The Port Redirect Function screen, Figure 5-14, allows the user to set
each one of the modules in the chassis (1 through 5), and the ports of the
corresponding module installed, as a source or destination port. A port
can be set to have one or more destination ports and chassis module slot
numbers. For example, port 1 in module (slot) 1 can be set as a source
port with three destinations, ports 2, 3, and 4 in module (slot) 3. Traffic
from port 1 in module 1 is then automatically redirected to ports 2, 3, and
4 in module 3. Port 1 in module 1 can also serve as a destination port for
other ports and modules. The port redirect function is extremely useful for
troubleshooting purposes, as it allows traffic to be sent to a particular
port(s) where, with the use of an analyzer or RMON probe, all current
traffic from the source port(s) can be examined.
The module number corresponds to the slot number in which
the module resides in the 6C105 chassis (1 through 5).
NOTES
Although traffic from the source port (including, if desired,
errored frames) is sent to the destination port, normal switching
is still performed for all frames on the source port.
Access the Port Redirect Function screen from the Chassis Menu screen
by using the arrow keys to highlight the PORT REDIRECT
FUNCTION menu item and pressing ENTER. The Port Redirect
Function screen, Figure 5-14, displays.
5-30
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Redirect Function Screen
Event Message Line
6C105 LOCAL MANAGEMENT
Port Redirect Function
Source
============
Destination
Remap Errors
============
============
Module Port
Module
Port
2
1
1
1
2
2
3
3
3
1
1
1
2
2
3
3
3
3
3
3
1
3
4
5
5
ON
ON
ON
OFF
ON
ON
ON
OFF
3
4
1
3
4
5
8
Status [ADD]
Errors [ON]
RETURN
RETURN
Source Port
[1]
Destination Port
[1]
Destination Module [1]
Source Module [1]
NEXT
PREVIOUS
SAVE
EXIT
1960_66
Figure 5-14 Port Redirect Function Screen
The following definitions briefly explain each field of the Port Redirect
Function screen.
Source Module (Read-Only)
Displays which modules are currently set as source modules.
Source Port (Read-Only)
Displays which ports are currently set as source ports.
Destination Module (Read-Only)
Displays which modules are currently set as destination modules.
Destination Port (Read-Only)
Displays which ports are currently set as destination ports.
Remap Errors (Read-only)
Displays whether the corresponding source modules and ports are
configured to send errored frames to the destination modules and ports, or
to drop all errored frames before forwarding traffic.
Source Module [n] (Selectable)
Allows a selected module [n] to be configured as a source module.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-31
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Source Port [n] (Selectable)
Allows a selected port [n] to be configured as a source port.
Destination Module [n] (Selectable)
Allows a selected module [n] to be configured as a destination module.
Destination Port [n] (Selectable)
Allows a selected port [n] to be configured as a destination port.
Errors (Toggle)
Allows the user to configure the source modules and ports to either send
errored frames to selected destination modules and ports ([ON] option),
or to drop errored frames, and send only valid traffic to the destination
modules and ports ([OFF] option). The default setting of this field is
[ON].
Status (Toggle)
Allows the user to add or delete the source/destination modules and ports
selected in the Source/Destination Modules and ports fields.
5.11.1 Displaying the Source and Destination Entries
There can be more than one Port Redirect Function screen depending on
the number of port redirect entries. Each screen displays up to ten port
redirect entries. If there is more than one screen of redirect entries, the
NEXT and/or PREVIOUS command is displayed at the bottom of the
screen, allowing the user to navigate to the next or previous screen.
To display the next screen, use the arrow keys to highlight NEXT. Press
ENTER and the next screen of entries is displayed.
To display the previous screen, use the arrow keys to highlight
PREVIOUS. Press ENTER to view the entries in the previous screen.
5-32
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Redirect Function Screen
5.11.2 Changing Source and Destination Ports
Add or delete source/destination module and port entries as follows:
1. Use the arrow keys to highlight the Source Module field.
2. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the module number displayed in the brackets [n] until the
appropriate module number is displayed.
3. Use the arrow keys to highlight the Source Port field.
4. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the port number displayed in the brackets [n] until the
appropriate port number is displayed.
5. Use the arrow keys to highlight the Destination Module field.
6. Use the SPACE bar or BACKSPACE to step to the appropriate
module number for the destination module.
7. Use the arrow keys to highlight the Destination Port field.
8. Use the SPACE bar or BACKSPACE to step to the appropriate port
number for the destination port.
9. Use the arrow keys to highlight the Status field.
10. Use the SPACE bar to select either the [ADD] or [DEL] (delete)
option. Press ENTER. This adds or deletes the selections made in steps
2 and 4 and also updates the screen Source Module, Source Port,
Destination Module and Destination Port lists.
11. Use the arrow keys to highlight the Errors field.
12. Use the SPACE bar to select either the [ON] or [OFF] option and
press ENTER. [ON] forces the source module and port to forward
errored frames to the destination module(s) and port(s). [OFF] forces
the errored frames to be dropped before forwarding traffic.
If more than one module and port is to be redirected, repeat
steps 1 through 12 for each additional setting, then go to step
NOTE
13 to save all the new settings at once.
13. Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” is displayed.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-33
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.12 MODULE SELECTION SCREEN
The Module Selection screen is the access point to Local Management for
all modules installed in the SmartSwitch 6000 chassis. By selecting a
module, the Module Menu for the selected device displays. Figure 5-15
shows the Module Selection screen.
6E122-26 LOCAL MANAGEMENT
Module Selection
Module #
Module Type
Serial #
Hardware Revision
<1>
2
6E122-26
6E132-25
6E123-26
6E122-26
123456789
123456789
123456789
123456789
XXX
XXX
XXX
XXX
3
4
5
EXIT
RETURN
Figure 5-15 Module Selection Screen
The following explains each Module Selection screen field as shown in
Figure 5-15.
Module #
The Module # field displays the slot in which the module is installed. The
module number enclosed in < > characters indicates the module to which
the management terminal or Telnet session is connected.
Module Type
The Module Type field displays the type of interface module that is
installed in each slot.
5-34
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Selection Screen
Serial #
Indicates the serial number of the module. The serial number of the device
is necessary when calling the Cabletron Systems Global Call Center.
Hardware Revision
Reflects the hardware version of the module.
5.12.1 Selecting a Module
To select an individual module to perform Local Management functions,
proceed as follows:
1. Use the arrow keys to highlight the desired module number in the
Module # field.
2. Press ENTER, the applicable Module Menu screen displays. Proceed
to Section 5.13.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-35
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.13 MODULE MENU SCREEN
The Local Management screens shown in this chapter are for
NOTE
most of the following Local Management screens. All Local
Management functions specific to any interface module are
preceded by a note to alert the reader.
The 6E12X-26 and 6E13X-25 Module Menu screens are the access point
for all Local Management screens for the 6E12X-26 and 6E13X-25.
Figure 5-16 shows the 6E122-26 Module Menu screen.
6E122-26 LOCAL MANAGEMENT
Module Menu
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
MODULE CONFIGURATION
MODULE STATISTICS
NETWORK TOOLS
EXIT
RETURN
1960_13
Figure 5-16 Module Menu Screen
5-36
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Menu Screen
The following explains each Module Menu screen field as shown in
Figure 5-16:
MODULE CONFIGURATION
The Module Configuration screen provides access to the Local
Management screens that are used to configure the 6E12X-26 and
6E13X-25. The Module Specific Configuration Menu screen provides
access to the screens that allow the user to check 6E12X-26 and
6E13X-25 resources and set operating parameters specific to each port.
Section 5.14. For details about the Module Specific Configuration Menu
screen, refer to Section 5.20.
MODULE STATISTICS
The Module Statistics screen provides statistics and performance
information for the 6E12X-26 and 6E13X-25. For details about this
screen, refer to Section 5.26.
NETWORK TOOLS
The Network Tools function resides on the 6E12X-26 and 6E13X-25 and
consists of a series of commands that allow the user to access and manage
network devices. Section 5.30 explains how to use the Network Tools
utility.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-37
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.14 MODULE CONFIGURATION MENU SCREEN
The Module Configuration Menu screen, Figure 5-17, provides access to
Local Management screens that allow you to configure and monitor
operating parameters, modify SNMP community names, set SNMP traps,
configure switch parameters and configure 6E12X-26 and 6E13X-25
ports.
The following menu items on the Module Configuration Menu
screen may not display if the operational mode of the module
NOTE
has been set to SECURE FAST VLAN:
SWITCH CONFIGURATION
SMARTTRUNK CONFIGURATION
Refer to your Release Notes to see if the functionality provided
by the above screens is supported in SECURE FAST VLAN
mode.
Section 5.15.9 provides instructions on setting the operational
mode.
Access the Module Configuration Menu screen from the Module Menu
screen by using the arrow keys to highlight the MODULE
CONFIGURATION menu item and pressing ENTER. The Module
Configuration screen displays.
5-38
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Configuration Menu Screen
6E122-26 LOCAL MANAGEMENT
Module Configuration Menu
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
GENERAL CONFIGURATION
SNMP COMMUNITY NAMES
SNMP TRAPS
SWITCH CONFIGURATION
ETHERNET FULL DUPLEX CONFIGURATION
SMARTTRUNK CONFIGURATION
MODULE SPECIFIC CONFIGURATION
EXIT
RETURN
1960_42
Figure 5-17 Module Configuration Menu Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-39
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
The following briefly explains each screen accessible from the Module
Configuration Menu screen:
GENERAL CONFIGURATION
The General Configuration screen allows the user to monitor and
configure operating parameters for the 6E12X-26 and 6E13X-25. For
details, refer to Section 5.15.
SNMP COMMUNITY NAMES
The SNMP Community Names screen allows the user to enter new,
change, or review the community names used as access passwords for
Local/Remote management operation. Access is limited based on the
password level of the user. For details, refer to Section 5.16.
SNMP TRAPS
table of IP addresses used for trap destinations and associated community
names. For details, refer to Section 5.17.
SWITCH CONFIGURATION
The Switch Configuration screen provides basic setup options for
modifying the switching functions of the modules. For details, refer to
Section 5.18.
ETHERNET FULL DUPLEX CONFIGURATION
The Ethernet Full Duplex Configuration screen allows each 10 Mbps port
(1 to 24) to be set for either Standard Ethernet or Full Duplex operation.
The screen also indicates whether or not each port is linked to another
Ethernet device and if that port is enabled. For details, refer to
Section 5.19.
SMARTTRUNK CONFIGURATION
The SmartTrunk Configuration screen allows the user to logically group
interfaces together to create a greater bandwidth uplink. Refer to the
Cabletron Systems SmartTrunk User’s Guide for additional information.
MODULE SPECIFIC CONFIGURATION
The Module Specific Configuration Menu screen allows the user to
configure ports or check system resources specific to the 6E12X-26 and
6E13X-25. For details, refer to Section 5.20.
5-40
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
5.15 GENERAL CONFIGURATION SCREEN
The General Configuration screen, Figure 5-18, allows the user to set the
system date and time, IP address and subnet mask, the default gateway,
the TFTP Gateway IP address, the Operational Mode, the Management
Mode, and the COM port configuration. The General Configuration
screen also allows the user to Clear NVRAM, and enable or disable IP
Fragmentation.
Access the General Configuration screen from the Module Configuration
Menu screen by using the arrow keys to highlight the GENERAL
CONFIGURATION menu item and pressing ENTER. The General
Configuration screen, Figure 5-18, displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
General Configuration
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
MAC Address:
00-00-ID-00-00-00
0.0.0.0
Module Date:
10/11/97
14:23:00
30 sec.
15 min.
IP Address:
Module Time:
Subnet Mask:
255.255.0.0
NONE DEFINED
0.0.0.0
Screen Refresh Time:
Screen Lockout Time:
Default Gateway:
TFTP Gateway IP Addr:
Module Uptime XX D XX H XX M
Operational Mode: [802.1D SWITCHING]
Management Mode: [DISTRIBUTED]
Com: [ENABLED]
Application:
[LM]
Clear NVRAM
[NO]
IP Fragmentation [ENABLED]
SAVE
EXIT
RETURN
1960_15
Figure 5-18 General Configuration Screen
The following briefly explains each General Configuration screen field:
MAC Address (Read-Only)
Displays the base physical address of the module.
IP Address (Modifiable)
This display allows the IP address to be set for the 6E12X-26 and
6E13X-25. To set the IP address, refer to Section 5.15.1.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-41
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Subnet Mask (Modifiable)
network bits of the IP address by setting the bits in the mask to 1 when the
network treats the corresponding bits in the IP address as part of the
network or subnetwork address, or to 0 if the corresponding bit identifies
the host. When an IP address is entered in the IP Address field, the subnet
mask field automatically enters the default subnet mask for the IP address.
For details about how to change the subnet mask from its default value,
refer to Section 5.15.2.
Default Gateway (Modifiable)
is not defined until an appropriate value is entered. For details about why
and how to set the Default Gateway, refer to Section 5.15.3.
TFTP Gateway IP Addr (Modifiable)
Displays and allows the user to set the TFTP Gateway IP address for the
6E12X-26 and 6E13X-25. To set the TFTP Gateway IP address, refer to
Section 5.15.4.
Module Date (Modifiable)
Contains a value that the module recognizes as the current date. To set a
new module date, refer to Section 5.15.5.
Module Time (Modifiable)
Contains a value that the module recognizes as the current time. To enter a
new time, refer to Section 5.15.6.
Screen Refresh Time (Modifiable)
Contains the rate at which the screens are updated. This setting
determines how frequently (in seconds) information is updated on the
screen. To enter a new update time, refer to Section 5.15.7.
5-42
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
Screen Lockout Time (Modifiable)
application displays a module’s screen while awaiting input or action
from a user. For example, if the number 5 is entered in this field, the user
has up to five minutes to respond to each of the specified module’s Local
Management screens. In this example, after five minutes of “idleness” (no
input or action), the terminal “beeps” five times, the Local Management
application terminates the session, and the display returns to the Password
screen. To enter a new lockout time, refer to Section 5.15.8.
Module Uptime (Read-Only)
Displays the total time that the module has been operating.
Operational Mode (Modifiable)
This field allows the user to set the 6E12X-26 and 6E13X-25 to operate as
a traditional switch (802.1D SWITCHING option), an IEEE 802.1Q
switch (802.1Q SWITCHING option), or as a Cabletron Systems
SecureFast switch (SECURE FAST VLAN option).
In 802.1D SWITCHING mode, the 24 ports located on the front panel,
and each Fast Ethernet Interface Module, and HSIM port(s) are bridged to
each other.
In 802.1Q SWITCHING mode, the 6E12X-26 and 6E13X-25 are able to
increase their switching functionality by creating and maintaining IEEE
port based VLANs.
When the operational mode is set to SECURE FAST VLAN, the
6E12X-26 and 6E13X-25 act as SecureFast switches. With the Cabletron
Systems VLAN Manager software, the modules are able to increase their
switching functionality by creating and maintaining Virtual LANs
(VLANs).
For details on how to select the Operational Mode, refer to Section 5.15.9.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-43
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Management Mode (Toggle)
This field toggles between DISTRIBUTED and STAND ALONE.
In DISTRIBUTED mode, Local Management is entered via the 6C105
password screen, and all chassis configuration screens are available to the
user. All other modules installed in the chassis that are set for distributed
management may also be accessed via a connection to a single COM port
on one of the modules.
In STAND ALONE mode, the module is isolated from the chassis
configuration screens, and the module may not be accessed from a module
that is in DISTRIBUTED mode. This provides additional security for any
module to which the user may wish to restrict access. Section 5.15.10
describes how to set the Management Mode.
Com (Toggle)
This field allows the user to enable or disable the COM port. The
selection toggles between ENABLED and DISABLED. The default is
ENABLED. For details about setting up the COM port, refer to
Section 5.15.11.
Application (Modifiable)
Displays the application set for the COM port. This field allows you to set
the application that the COM port will support, which includes:
•
•
Local Management (LM) via a terminal or modem connection
Uninterruptible Power Supply (UPS)
The UPS setting allows you to use the COM port to monitor an American
Power Conversion Uninterruptible Power Supply (UPS). For UPS, the
baud rate is automatically set to 2400.
The baud rate setting for LM is automatically sensed.
For details about how to configure the COM port for various applications,
refer to Section 5.15.11.
5-44
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
Clear NVRAM (Toggle)
This allows the user to reset NVRAM to the factory default settings. All
user-entered parameters, such as IP address and Community Names are
then replaced with 6E12X-26 and 6E13X-25 default configuration
settings. For details, refer to Section 5.15.13.
IP Fragmentation (Toggle)
This field allows the user to enable or disable IP fragmentation. The
default setting for this field is ENABLED. If the 6E12X-26 or 6E13X-25
will be bridged to an FDDI ring, IP Fragmentation should be enabled. If
IP Fragmentation is disabled, all FDDI frames that exceed the maximum
Ethernet frame size will be discarded. For details on enabling or disabling
IP Fragmentation refer to Section 5.15.14.
5.15.1 Setting the IP Address
To set the IP address, perform the following steps:
If the 6C105 chassis has been assigned an IP address, it is not
necessary to assign an IP address to the 6E12X-26 and
NOTE
6E13X-25. All installed modules have the same IP address as
the chassis. If a separate IP address for the module is desired,
proceed as follows.
1. Use the arrow keys to highlight the IP Address field.
2. Enter the IP address into this field using Decimal Dotted Notation
(DDN) format.
For example: 134.141.79.120
the beginning of the IP address field. If the entry is not valid, the Event
Message Line displays “INVALID IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-45
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
WARNING!
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS MODULE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
NO
174252
Figure 5-19 Configuration Warning Screen
5. Use the arrow keys to highlight the YES command and Press ENTER.
The changes are saved and the module reboots.
5.15.2 Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6E12X-26 and 6E13X-25 is located on a separate subnet, the subnet mask
for the 6E12X-26 and 6E13X-25 must be changed from its default.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
5-46
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
beginning of the Subnet Mask field. If the entry is not valid, the Event
Message Line displays “INVALID SUBNET MASK OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the Subnet Mask field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
5. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots
5.15.3 Setting the Default Gateway
If the SNMP management station is located on a different IP subnet than
the 6E12X-26 and 6E13X-25, a default gateway must be specified. When
an SNMP Trap is generated, the 6E12X-26 and 6E13X-25 sends the Trap
to the default gateway. To set the default gateway, perform the following
steps:
1. Use the arrow keys to highlight the Default Gateway field.
2. Enter the IP address of the default gateway using the DDN format.
For example: 134.141.79.121
3. Press ENTER. If the default gateway entered is a valid format, the
cursor returns to the beginning of the Default Gateway field. If the
entry is not valid, the Event Message Line displays “INVALID
DEFAULT GATEWAY OR FORMAT ENTERED”. Local
Management does not alter the current value, but it does refresh the
Default Gateway field with the previous value.
4. Use the arrow keys to highlight the SAVE command.
5. Press ENTER. The Event Message Line at the top of the screen
displays “SAVED OK”.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-47
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.15.4 Setting the TFTP Gateway IP Address
If the network TFTP server is located on a different IP subnet than the
6E12X-26 and 6E13X-25, a Gateway IP address should be specified. To
set the TFTP Gateway IP address, perform the following steps:
1. Use the arrow keys to highlight the TFTP Gateway IP Address field.
2. Enter the IP address of the TFTP gateway using the DDN format.
For example: 134.141.80.122
3. Press ENTER. If the TFTP gateway IP address entered is a valid
format, the cursor returns to the beginning of the TFTP Gateway IP
Address field. If the entry is not valid, the Event Message Line
displays “INVALID TFTP GATEWAY IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the TFTP Gateway IP Address field with the previous
value.
4. Use the arrow keys to highlight the SAVE command.
5. Press ENTER. The Event Message Line at the top of the screen
displays “SAVED OK”.
5.15.5 Setting the Module Date
The modules are year 2000 compliant, so the module date may be set
beyond the year 1999. To set the module date, perform the following
steps:
If the 6C105 chassis has been assigned a chassis date, it is not
necessary to assign a module date to the 6E12X-26 and
NOTE
6E13X-25. All installed modules recognize the chassis date of
the 6C105.
1. Use the arrow keys to highlight the Module Date field.
2. Enter the date in an MM/DD/YYYY format.
It is not necessary to add separators between month, day, and
year numbers. For example, to set the date to 03/17/1997, type
NOTE
“03171997” in the Module Date field.
5-48
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
3. Press ENTER to set the system calendar to the date in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the date entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value, but it does refresh the
Module Date field with the previous value.
5.15.6 Setting the Module Time
To set the module clock, perform the following steps:
If the 6C105 chassis has been assigned a chassis time, it is not
necessary to assign a module time to the 6E12X-26 and
NOTE
6E13X-25. All installed modules recognize the chassis time of
the 6C105.
1. Use the arrow keys to highlight the Module Time field.
2. Enter the time in an 24-hour format, HH:MM:SS.
When entering the time in the system time field, separators
between hours, minutes, and seconds do not need to be added
NOTE
as long as each entry uses two numeric characters. For
example, to set the time to 6:45 A.M., type “064500” in the
Module Time field.
3. Press ENTER to set the system clock to the time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value and refreshes the Module
Time field with the previous value.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-49
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.15.7 Entering a New Screen Refresh Time
The screen refresh time is set from 3 to 99 seconds with a default of 3
seconds. To set a new screen refresh time, perform the following steps:
1. Use the arrow keys to highlight the Screen Refresh Time field.
2. Enter a number from 3 to 99.
3. Press ENTER to set the refresh time to the time entered in the input
field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 3 to 99 seconds range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Refresh Time field with the previous value.
5.15.8 Setting the Screen Lockout Time
The screen lockout time can be set from 1 to 30 minutes with a default of
15 minutes. To set a new lockout time, perform the following steps:
1. Use the arrow keys to highlight the Screen Lockout Time field.
2. Enter a number from 1 to 30.
3. Press ENTER to set the lockout time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
5-50
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
5.15.9 Setting the Operational Mode
Before setting the operational mode, ensure that the items
contained in this caution are fully understood.
!
CAUTION
If the module will be configured to operate as a SecureFast
switch the following procedures should be performed before
setting the operational mode:
The module must be assigned a unique IP address.
The Management Mode of the module will automatically be set
to STANDALONE. The Management Mode field will no longer
display on the General Configuration screen, and the module
will no longer support Chassis configuration and Module
selection screens. If the module will be a SecureFast switch,
distributed management is not allowed.
The module has been assigned SNMP community names from
the module SNMP Community Names screen (Section 5.16).
In Standalone management mode, the module does not use
the community names of the 6C105 chassis.
To set the Operational Mode, proceed as follows:
1. Use arrow keys to highlight the Operational Mode field.
2. Press the SPACE bar to step to the appropriate operation mode,
(802.1D SWITCHING, 802.1Q SWITCHING, or SECURE FAST
VLAN).
3. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
Upon saving the new operational mode, the module will reboot.
NOTE
If the 6E12X-26 and 6E13X-25 have been set to 802.1Q
SWITCHING, refer to your Port Based VLAN User’s Guide to
configure the devices for this type of operation.
If the 6E12X-26 and 6E13X-25 have been set to SECURE
FAST VLAN, refer to your SecureFast documentation set to
configure the devices for this type of operation.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-51
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.15.10 Setting the Management Mode
To set the management mode, perform the following steps:
Upon saving the new Management Mode, the module will
reboot.
NOTE
If the module will be set to STANDALONE, ensure the following
procedures have been completed:
The module has been assigned a unique IP address.
The module has been assigned SNMP community names from
the module SNMP Community Names screen (Section 5.16).
In STAND ALONE management mode, the module does not
use the community names of the 6C105 chassis.
1. Use the arrow keys to highlight the Management Mode field:
2. Use the SPACE bar to toggle the options (DISTRIBUTED or
STAND ALONE) until the desired mode displays.
3. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
5-52
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
5.15.11 Configuring the COM Port
Before altering the COM port settings, ensure that a valid IP
address is set for the module or chassis. (Refer to
Section 5.15.1, Setting the IP Address.) Read this entire
COM port configuration section before changing the settings of
the COM port.
!
CAUTION
The 6E12X-26 and 6E13X-25 COM ports support the following
applications:
Refer to the Release Notes included with the 6E12X-26 and
6E13X-25 to verify which COM Port applications are currently
NOTE
supported.
•
•
Local Management connections
American Power Conversion Uninterruptible Power Supply (UPS)
connections
To configure the COM port, proceed as follows:
1. Use the arrow keys to highlight the Com field.
Do NOT disable or alter the settings of the COM port while
operating the current Local Management connection through a
terminal. Altering the COM port settings disconnects the Local
Management terminal from the port, and ends the Local
Management session.
!
CAUTION
2. Press the SPACE bar to choose either ENABLED or DISABLED.
The COM port must be ENABLED if it will be used for Local
Management or UPS applications. Select DISABLED if you wish to
disable the COM port for additional module security.
If the COM port is reconfigured without a valid IP address set
on the module or chassis, the message shown in Figure 5-20
displays. Do not continue unless the outcome of the action is
fully understood.
!
CAUTION
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-53
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
WARNING
THE COM PORT HAS BEEN RECONFIGURED AND THERE IS NO IP
ADDRESS SET FOR THIS DEVICE. YOU WILL NO LONGER BE ABLE
TO MANAGE THIS BOARD. DO YOU STILL WISH TO RECONFIGURE
THIS COM PORT?
NO
YES
174252
Figure 5-20 COM Port Warning Screen
If the 6C105 chassis has been configured with a valid IP
address this screen will not appear. When the chassis is
NOTE
assigned a valid IP address all the interface modules installed
share this same address.
3. Use the arrow keys to highlight YES. Press ENTER.
4. If you ENABLED the port, proceed to Section 5.15.12. If you
DISABLED the port, use the arrow keys to highlight SAVE at the
bottom of the screen, then press ENTER. When the message “SAVED
OK” displays, the edits are saved.
Exiting without saving causes the message “NOT SAVED --
PRESS SAVE TO KEEP CHANGES” to appear. Exiting without
saving causes all edits to be lost.
!
CAUTION
5-54
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
General Configuration Screen
5.15.12 Changing the Com Port Application
After enabling the COM port as described in Section 5.15.11, you can
select one of the applications supported by the COM port: LM, and UPS.
The default application is LM.
To change the COM port application:
1. Use the arrows keys to highlight the Application field.
2. Use the SPACE bar or BACKSPACE to step through the available
settings until the operation you require appears. Table 5-3 lists the
available settings and their corresponding applications.
Table 5-3. COM Port Application Settings
Setting
Application
LM
Local Management Session
UPS
APC Power Supply SNMP Proxy
3. Press ENTER to accept the application.
4. Use the arrow keys to highlight SAVE at the bottom of the screen, then
press the ENTER key.
5. When the message “SAVED OK” appears, the edits you made are
saved.
When the COM port is configured to perform the UPS
application, all future Local Management connections must be
made by establishing a Telnet connection to the module.
!
CAUTION
Ensure that the module has a valid IP address before saving
changes to the COM port application. If the module does not
have a valid IP address and the changes are saved, refer to
Appendix C for instructions on clearing NVRAM in order to
reestablish COM port communications.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-55
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.15.13 Clearing NVRAM
Clearing NVRAM will result in the loss of all user-entered
parameters. Do not proceed unless this procedure is
completely understood.
!
CAUTION
Clearing NVRAM allows the user to clear all user-entered parameters,
such as IP address and Community Names from NVRAM.
Clear NVRAM as follows:
1. Use the arrow keys to highlight the Clear NVRAM field.
2. Use the SPACE bar to toggle the field to YES.
3. Use the arrow keys to highlight SAVE at the bottom of the screen.
4. Press ENTER. The warning shown in Figure 5-21 is displayed.
WARNING
YOU HAVE ELECTED TO CLEAR NVRAM. THIS WILL CLEAR
ALL SYSTEM DEFAULTS INCLUDING BUT NOT LIMITED TO
IP ADDRESS, INTERFACE CONFIGURATION, AND COM PORT
CONFIGURATION, THEN RESET THE BOARD.
ARE YOU SURE YOU WANT TO CLEAR NVRAM?
NO
YES
174251
Figure 5-21 Clear NVRAM Warning Screen
5. Use the arrow keys to highlight YES and press ENTER. The message
“CLEARING NVRAM. REBOOT IN PROGRESS...” displays.
The 6E12X-26 and 6E13X-25 clear NVRAM and reboot. All user-entered
parameters default to factory settings.
5-56
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Community Names Screen
5.15.14 Enabling/Disabling IP Fragmentation
To enable or disable IP fragmentation, proceed as follows:
1. Use the arrow keys to highlight the IP Fragmentation field.
2. Press the SPACE bar to choose either ENABLED or DISABLED.
3. Use the arrow keys to highlight the SAVE command.
4. Press ENTER. The Event Message Line at the top of the screen
displays “SAVED OK”.
If the 6E12X-26 and 6E13X-25 are being bridged to an FDDI
ring (for example, via an HSIM-F6 installed in the 6E13X-25) IP
Fragmentation should be enabled. If IP Fragmentation is
disabled, all FDDI frames that exceed the maximum Ethernet
frame size will be discarded.
!
CAUTION
5.16 SNMP COMMUNITY NAMES SCREEN
The SNMP Community Names menu item allows the user to set
Local/Remote Management community names. Community names act as
passwords to Local/Remote Management and are agents of security
access to the 6E12X-26 and 6E13X-25. Access to the 6E12X-26 and
6E13X-25 is controlled by enacting any of three different levels of
security authorization (read-only, read-write, and super-user).
If the 6C105 has been assigned community names, it is not
necessary to assign community names to the individual
NOTE
modules installed in the chassis unless the user wishes to limit
access to 6C105 chassis screens by assigning different
community names to the module. When this is done access is
limited to the screens specific to the module to which the
terminal is attached and the Local Management session begins
at the Module Menu screen.
Super-User access gives the user full management privileges,
allows existing passwords to be changed, and all modifiable
MIB objects for the Cabletron Container MIB and Internet
MIB-II to be accessed.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-57
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Access the SNMP Community Names screen from the Module
Configuration Menu screen by using the arrow keys to highlight the
SNMP COMMUNITY NAMES menu item and pressing ENTER. The
SNMP Community Names screen, Figure 5-22, displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
SNMP Community Names
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Community Name
public
Access Policy
read-only
read-write
super-user
public
public
SAVE
EXIT
RETURN
Figure 5-22 SNMP Community Names Screen
The following explains each SNMP Community Names screen field:
Community Name (Modifiable)
Displays the user-defined name through which a user accesses 6E12X-26
and 6E13X-25 management. Any community name assigned here acts as
a password to Local/Remote Management.
Access Policy (Read-Only)
Indicates the access accorded each community name. Possible selections
are as follows:
read-only
This community name allows read-only access
to the 6E12X-26 and 6E13X-25 MIB objects,
and excludes access to security-protected fields
of read-write or super-user authorization.
5-58
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Community Names Screen
read-write
super-user
This community name allows read and write
access to the 6E12X-26 and 6E13X-25 MIB
objects, excluding security protected fields for
super-user access only.
This community name permits read-write
access to the 6E12X-26 and 6E13X-25 MIB
objects and allows the user to change all
modifiable parameters including community
names, IP addresses, traps, and SNMP objects.
5.16.1 Establishing Community Names
The password used to access Local Management at the Password Screen
must have Super-User access in order to view and edit the SNMP
Community Names screen. Using a password with read-only or
read-write access does not allow the user to view or edit the SNMP
Community Names screen.
Any community name assigned in the SNMP Community
Names screen is a password to its corresponding level of
NOTE
access to Local/Remote Management. The community name
assigned Super-User access is the only one that gives the user
complete access to Local/Remote Management.
To establish community names, proceed as follows:
1. Use the arrow keys to highlight the Community Name field adjacent
to the selected access level.
2. Enter the password in the field (maximum 31 characters).
3. Press ENTER.
4. Repeat steps 1 through 3 to modify the other community names.
5. Use the arrow keys to highlight SAVE at the bottom of the screen and
press ENTER. The message “SAVED OK” displays. The community
names are saved to memory and their access modes implemented.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-59
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Since the 6E12X-26 and 6E13X-25 are SNMP compliant devices, they
can send messages to multiple Network Management Stations to alert
users of status changes. The SNMP Traps screen is shown in Figure 5-23.
It is only necessary to assign SNMP traps if the user desires
the traps to be sent to different addresses than those assigned
NOTE
in Section 5.9, which details how to set SNMP Traps for the
6C105 chassis.
Access the SNMP Traps screen from the Module Configuration Menu
screen by using the arrow keys to highlight the SNMP TRAPS field and
pressing ENTER. The SNMP Traps screen displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
SNMP Traps
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Trap Destination
0.0.0.0
Trap Community Name
public
Enable Traps
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
0.0.0.0
public
[NO]
SAVE
EXIT
RETURN
1960_17
Figure 5-23 SNMP Traps Screen
The following explains each field of the SNMP Traps screen.
Trap Destination (Modifiable)
Indicates the IP address of the workstation to receive trap alarms. Up to
eight different destinations can be defined.
5-60
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Traps Screen
Trap Community Name (Modifiable)
Displays the Community Name included in the trap message sent to the
Network Management Station with the associated IP address.
Enable Traps (Toggle)
Enables transmission of the traps to the network management station with
the associated IP address. This field toggles between YES and NO.
5.17.1 Configuring the Trap Table
To configure the Trap Table, proceed as follows:
1. Using the arrow keys, highlight the appropriate Trap Destination
field.
2. Enter the IP Address of the workstation that is to receive traps. IP
address entries must follow the DDN format.
For example: 134.141.79.121
3. Press ENTER. If an invalid entry is entered “INVALID IP
ENTERED” is displayed in the Event Message Line.
4. Using the arrow keys, highlight the Trap Community Name field.
Enter the community name.
5. Press ENTER.
6. Using the arrow keys, highlight the Enable Traps field. Press the
SPACE bar to choose either YES (send alarms from the module to the
workstation), or NO (prevent alarms from being sent).
7. Using the arrow keys, highlight the SAVE option and press ENTER.
The message “SAVED OK” displays on the screen.
The designated workstations now receive traps from the 6E12X-26 and
6E13X-25.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-61
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.18 SWITCH CONFIGURATION SCREEN
The Switch Configuration screen will not be available if the
operational mode of the module has been set to SECURE
NOTE
FAST VLAN. This screen may only be used by modules
configured to operate as traditional or 802.1Q switches.
The Switch Configuration screen, Figure 5-24, provides the basic setup
options to make a switch operational in your network.
Access the Switch Configuration screen from the Module Configuration
Menu screen by using the arrow keys to highlight the SWITCH
CONFIGURATION field and pressing ENTER. The Switch
Configuration screen, Figure 5-24, displays ports 1 through 8. To view or
edit the fields for ports 9 to 16, highlight [9-16] at the bottom of the
screen and press the ENTER key. Perform the function again to view or
edit ports 17 to 24, and once again to view or edit ports 25 to 30.
Ports 25 and 26 on the Switch Configuration screen represent
the optional Fast Ethernet Interface Modules available for the
NOTE
6E12X-26.
Port 25 on the Switch Configuration screen represents the
optional HSIM available for the 6E13X-25.
Ports 27 through 30 (6E12X-26) or 26 through 29 (6E13X-25)
on the Switch Configuration screen represent the backplane
connections that the module has with the 6C105 chassis. The
module has a direct connection to every other slot in the
chassis.
5-62
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Switch Configuration Screen
Event Message Line
6E122-26 LOCAL MANAGEMENT
Switch Configuration
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Switch Address: 00-00-1D-00-00-00
Number of Ports: 30
Type of STA:
Age Time:
[DEC]
300
Port #
MAC Address
State
Status
1
2
3
4
5
6
7
8
00-00-1D-00-00-00
00-00-1D-00-00-01
00-00-1D-00-00-02
00-00-1D-00-00-03
00-00-1D-00-00-04
00-00-1D-00-00-05
00-00-1D-00-00-06
00-00-1D-00-00-07
learning
listening
standby
learning
listening
standby
listening
listening
[ENABLED]
[DISABLED]
[ENABLED]
[DISABLED]
[ENABLED]
[DISABLED]
[ENABLED]
[DISABLED]
[9-16]
SAVE
EXIT
RETURN
Figure 5-24 Switch Configuration Screen
The following describe each field of the Switch Configuration screen:
Switch Address (Read-Only)
Displays the base MAC address of the switch.
Number of Ports (Read-Only)
Displays the total number of switched ports on the module.
Type of STA (Toggle)
Allows the user to set the method that switches use to decide which
switch is the controlling (Root) switch when two or more switches exist in
parallel (Spanning Tree Algorithm). Valid entries include IEEE, DEC,
and NONE. To set the STA, refer to Section 5.18.1.
Age Time (Modifiable)
Allows the user to set the amount of time (in seconds) the 6E12X-26 and
6E13X-25 will keep an address in its switch table before discarding it.
The modules will discard an address from their switch table if they do not
receive a valid packet from the applicable address in the amount of time
specified in the Age Time field. To change the Age Time field from the
default value of 300 seconds, refer to Section 5.18.2.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-63
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Port # (Read-Only)
Lists each switch port on the module. If the number of ports is greater
than eight, then the additional ports are listed on subsequent screens.
MAC Address (Read-Only)
Displays the hardware address assigned to each listed port.
State (Read-Only)
Disabled: Management disabled this interface. No traffic is received or
forwarded while the interface is disabled.
Listening: The switch is not adding information to the Transparent
Database. The switch is monitoring BPDU traffic while preparing to
move from the learning to the forwarding state.
Learning: The switch is learning the network address of this interface.
The switch enters the learning state when the Transparent Database is
created (during start-up or after being deleted), or when the Spanning
Tree Algorithm detects a network topology change.
Forwarding: The switch is on line and this interface is forwarding traffic.
Standby: This interface will not forward any traffic through the switch
because a loop condition has been detected by the STA.
Status (Toggle)
Allows the user to disable or enable a port by setting the status of the
listed interface to either ENABLED or DISABLED. To set the port status,
refer to Section 5.18.3.
5.18.1 Setting the STA
The Spanning Tree Algorithm (STA) setting allows the user to set the
method that the switches use to decide which is the controller (Root)
switch when two or more switches are in parallel. The available selections
are IEEE, DEC, and NONE.
To set the STA, proceed as follows:
1. Use the arrow keys to highlight the Type of STA field.
2. Use the SPACE bar to step to the appropriate setting (IEEE, DEC, or
NONE).
5-64
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Switch Configuration Screen
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
5.18.2 Setting the Age Time
To set the Age Time, proceed as follows:
1. Use the arrow keys to highlight the Age Time field.
2. Enter the desired Age Time in increments of 10. The available Age
Time range is 10 seconds to 1,000,000 seconds with the default value
being 300 seconds.
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
5.18.3 Setting (Enabling or Disabling) the Port Status
To set the status of an interface (port), proceed as follows:
Disabling the port status of a backplane connection will block
the module from passing user traffic to the applicable module
NOTE
slot in the 6C105 chassis. SNMP and other management traffic
(e.g., ping and Telnet traffic), however, will still pass via the
backplane to the applicable module slot.
1. Use the arrow keys to highlight the Status field of the port.
2. Use the SPACE bar to toggle to either ENABLED or DISABLED.
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-65
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.19 ETHERNET FULL DUPLEX CONFIGURATION
SCREEN
The Ethernet Full Duplex Configuration screen, Figure 5-25, allows the
user to set ports 1 through 24 for either Standard Ethernet or Full Duplex
linked to another device.
Access the Ethernet Full Duplex Configuration screen from the Module
Specific Configuration Menu screen by using the arrow keys to highlight
the ETHERNET FULL DUPLEX CONFIGURATION menu item in
the Module Specific Configuration Menu screen and press ENTER. The
Ethernet Full Duplex Configuration screen, Figure 5-25, displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
Full Duplex Configuration
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
PORT #
OPERATION MODE
LINK STATUS
Link
PORT STATUS
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
1
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
2
Link
3
Link
4
No Link
Link
5
6
Link
7
Link
8
Link
9
Link
10
11
12
Link
Link
Link
RETURN
EXIT
RETURN
SAVE
SET ALL PORTS: [FULL ]
[13-24]
1960_21
Figure 5-25 Ethernet Full Duplex Configuration Screen
5-66
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Ethernet Full Duplex Configuration Screen
The following section explains each field of the Ethernet Full Duplex
Configuration screen.
PORT # (Read-only)
Identifies the number of the port.
OPERATION MODE (Toggle)
Allows the user to set the specified port to transmit and receive data
separately or simultaneously. Set this field to one of the following values:
•
STANDARD ENET – The port is running at 10 Mbps (default) and
either transmits data or receives data, but not both at the same time. To
set Ethernet ports for Full Duplex operation, refer to Section 5.19.1.
•
FULL DUPLEX – The port transmits and receives data at the same
time (full duplex) and operates at 20 Mbps. To set Ethernet ports for
Full Duplex operation, refer to Section 5.19.1.
LINK STATUS (Read-only)
Indicates whether there is a physical connection from this port to another
Ethernet device. One of the following values displays:
•
Link – There is a valid link signal present; there is a valid physical
connection from this port to another device.
•
No Link – There is no valid link signal present; there is no valid
physical connection from this port to another device.
PORT STATUS (Read-only)
Indicates whether the port was turned on or off administratively. One of
the following values is displayed:
•
•
ENABLED – The port is turned on administratively.
DISABLED – The port is turned off administratively.
Enabling or disabling ports from the Switch Configuration
screen is described in Section 5.18.3.
NOTE
SET ALL PORTS (Toggle)
Ports 1 through 24 can be set all at once to either STANDARD or FULL
from this field. To set all ports, refer to Section 5.19.1.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-67
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
[1-12], or [13-24] (Navigation Key)
When the Full Duplex Configuration screen displays, the current
operation mode and status information are displayed for the first 12 ports.
This field allows the user to step to a second screen for the same type of
information for ports 13 through 24. While on the second screen, the user
can navigate back to the first screen by selecting the [1-12] option. The
user can change the Operation Mode fields while in either the first or
second screen.
5.19.1 Setting the Operation Mode
The Operation Mode may be set to Standard Ethernet or Full Duplex
either one port at a time or all at once. The following steps describe
setting the port Operation Mode for individual ports followed by steps to
set the Operation Mode for all ports.
Set the Operation Mode for individual ports as follows:
1. Use the arrow keys to highlight the OPERATION MODE field
adjacent to the number of the port that you plan to change.
The Operation Mode for the first 12 ports can be changed on
the first screen. To display the Operation Mode for Ports 13
NOTE
through 24, use the arrow keys to highlight the Ports [13-24]
field and press ENTER. To again display the Operation Mode
for Ports 1 through 12, use the arrow keys to highlight the Ports
[1-12] field and press ENTER.
2. Press the SPACE bar until the appropriate mode (FULL DUPLEX or
STANDARD ENET) is displayed.
3. Use the arrow keys to highlight the SAVE command on the bottom
line of the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
To set all 24 Ethernet ports for Full Duplex or Standard Ethernet, proceed
as follows:
1. Use the arrow keys to highlight the SET ALL PORTS field.
2. Press the SPACE bar until you see FULL or STANDARD.
3. Use the arrow keys to highlight the SAVE command on the bottom
line of the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
5-68
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Specific Configuration Menu Screen
5.20 MODULE SPECIFIC CONFIGURATION MENU
SCREEN
The Module Specific Configuration Menu screen, Figure 5-26, allows the
user to select one of five screens to configure ports or check system
resources specific to the 6E12X-26 and 6E13X-25.
The following menu items on the Module Specific Configuration
Menu screen may not display if the operational mode of the
NOTE
module has been set to SECURE FAST VLAN or 802.1Q
SWITCHING:
PORT REDIRECT FUNCTION
BROADCAST SUPPRESSION
Refer to your Release Notes to see if the functionality provided
by the above screens is supported.
Section 5.15.9 provides instructions on setting the operational
mode.
Access the Module Specific Configuration Menu screen from the Module
Configuration Menu screen by using the arrow keys to highlight the
MODULE SPECIFIC CONFIGURATION MENU menu item and
pressing ENTER. The Module Specific Configuration Menu screen
displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-69
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
6E122-26 LOCAL MANAGEMENT
Module Specific Configuration Menu
Firmware Revision:
BOOTPROM Revision: XX.XX.XX
Module Type: 6E122-26
XX.XX.XX
Slot Number: X
SYSTEM RESOURCES
HIGH SPEED INTERFACE CONFIGURATION
FLASH DOWNLOAD
PORT REDIRECT FUNCTION
BROADCAST SUPPRESSION
EXIT
RETURN
1960_20
Figure 5-26 Module Specific Configuration Menu Screen
The following explains each field of the Module Specific Configuration
Menu screen:
SYSTEM RESOURCES
The System Resources screen displays the amount of FLASH memory,
DRAM, and NVRAM installed, details how much memory is available
and provides information on 6E12X-26 and 6E13X-25 operation. For
details, refer to Section 5.21.
HIGH SPEED INTERFACE CONFIGURATION
The High Speed Interface Configuration screen indicates which Fast
Ethernet Interface Modules are installed in ports 25 and 26 of the
6E12X-26, their current operating mode, and if the ports are linked. It
also permits the Auto-Negotiation and Advertised Ability features to be
enabled or disabled. For details, refer to Section 5.22.
The High Speed Configuration screen for the 6E13X-25 allows
management of the installed HSIM. For details, refer to the applicable
HSIM User’s Guide.
5-70
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Specific Configuration Menu Screen
FLASH DOWNLOAD
The FLASH Download screen allows the user to force the 6E12X-26 and
6E13X-25 to download a new image file to FLASH memory from a TFTP
PORT REDIRECT FUNCTION
The Port Redirect Function screen allows the user to redirect traffic from
one or more ports on the module to a specific destination port on the
module. For details, refer to Section 5.24.
Section 5.15.9, Setting the Operational Mode, describes how to
configure the modules to function as 802.1D switches.
BROADCAST SUPPRESSION
The Broadcast Suppression screen allows the user to set a desired limit of
receive broadcast frames per port per second. For details, refer to
Section 5.25.
802.1Q VLAN Configuration
This menu item will only display if the module has been configured to
operate as an IEEE 802.1Q switch and the Management Mode has been
set to STAND ALONE. When selected, this menu item opens the VLAN
Main Menu screen. For details, refer to the Cabletron Systems Port Based
VLAN User’s Guide. Section 5.15.9, Setting the Operational Mode,
describes how to configure the modules to function as 802.1Q switches.
the module to STAND ALONE management mode.
The module does not have to be in STAND ALONE mode to
operate as an 802.1Q switch. In DISTRIBUTED management
NOTE
mode, 802.1Q VLANs are created and maintained via the
802.1Q VLAN CONFIGURATION menu item on the Chassis
Menu screen. Refer to Section 5.6 for details.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-71
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.21 SYSTEM RESOURCES SCREEN
The System Resources screen, Figure 5-27, provides information
concerning the processor, the amount of FLASH memory, DRAM, and
NVRAM that is installed and how much of that memory is available.
Access the System Resources screen from the Module Specific
Configuration Menu screen by using the arrow keys to highlight the
SYSTEM RESOURCES menu item and pressing ENTER. The System
Resources screen displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
System Resources
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Module Uptime: X Days XHrs XMins
BOOTPROM Revision: XX.XX.XX
CPU Type: i960 HT 75Mhz
Flash Memory Installed : 4 MB
Available:
XXXXX Bytes
XXXXX Bytes
XXXXX Bytes
DRAM Installed:
NVRAM Installed:
16 MB
Available:
Available:
XX KB
Current Switch Utilization: 66%
Peak Switch Utilization: 75%
Reset Peak Switch Utilization: [NO]
RETURN
RETURN
SAVE
EXIT
1960_23
Figure 5-27 System Resources Screen
The following briefly explains each field of the System Resources screen.
Module Uptime (Read-only)
The time in days/hours/minutes that the module has been continuously
running.
CPU Type (Read-only)
Indicates the microprocessor used in the 6E12X-26 and 6E13X-25.
5-72
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
System Resources Screen
Flash Memory Installed (Read-only)
Indicates the amount of FLASH memory installed in the 6E12X-26 and
6E13X-25 and how much is currently available.
DRAM Installed (Read-only)
Indicates the amount of DRAM installed in the 6E12X-26 and 6E13X-25
and how much of it is currently available.
NVRAM Installed (Read-only)
Indicates the amount of NVRAM installed in the 6E12X-26 and
6E13X-25 and how much of it is currently available.
Current Switch Utilization (Read-only)
Shows how much (percentage of capacity) the 6E12X-26 and 6E13X-25
is currently being used.
Peak Switch Utilization (Read-only)
Shows the peak percentage of maximum switching capacity, since last
reset.
Reset Peak Switch Utilization (Toggle)
Allows the user to reset the Peak Switch Utilization field. The switch may
be set to either YES or NO as described in Section 5.21.1. YES resets the
Peak Switch Utilization field to the current system traffic.
5.21.1 Setting the Reset Peak Utilization
To set the Reset Peak Utilization field to YES or NO, proceed as follows:
1. Use the arrow keys to highlight the Peak Switch Utilization field.
2. Press the SPACE bar to select YES or NO.
3. Use the arrows keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-73
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.22 HIGH SPEED INTERFACE CONFIGURATION MENU
SCREEN (6E12X-26 ONLY)
When the HIGH SPEED CONFIGURATION MENU is selected
for the 6E13X-25 the applicable HSIM Setup screen displays.
NOTE
Refer to the HSIM User’s Guide to set operating parameters for
the HSIM installed in the 6E13X-25.
Access the High Speed Interface Configuration Menu screen from the
Module Specific Configuration Menu screen by using the arrow keys to
highlight the HIGH SPEED INTERFACE CONFIGURATION
MENU menu item and pressing ENTER. The High Speed Interface
Configuration screen displays.
The High Speed Interface Configuration screen, Figure 5-28,
applies only to ports 25 and 26 of the 6E12X-26. This screen
NOTE
supports the FE-100TX, FE-100FX and FE-100F3 Fast
Ethernet Interface Modules that operate at 100 Mbps. If you are
configuring a 6E13X-25, refer to the applicable HSIM User’s
Guide, or proceed to Section 5.23.
The High Speed Interface Configuration screen displays the types of
interfaces installed in ports 25 and 26, their current operating mode, and
indicates if the ports are linked. This screen also allows the user to enable
or disable Auto-Negotiation and set the Advertised Ability.
5-74
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
High Speed Interface Configuration Menu Screen (6E12X-26 Only)
Event Message Line
6E122-26 LOCAL MANAGEMENT
High Speed Interface Configuration
Firmware Revision:
XX.XX.XX
Module Type: 6E122-26
BOOTPROM Revision: XX.XX.XX
Slot Number: X
Port 25
Port 26
Unknown
No Link
[N/A]
Port Type
FE-100TX
Link Status
Link
Current Oper. Mode
Desired Oper. Mode
Advertised Ability
100Base-TXFD
[Auto-Negotiation]
[100Base-TXFD]
[N/A]
[Disabled]
[N/A]
SAVE
EXIT
RETURN
Figure 5-28 High Speed Interface Configuration Screen for the 6E12X-26
The following briefly explains each field of the High Speed Interface
Configuration screen.
Port Type (Read-Only)
Displays the name of the interface (FE-100FX, FE-100TX or FE-100F3)
installed in ports 25 and 26. Figure 5-28 shows that there is an FE-100TX
interface installed in port 25 and no interface, indicated by Unknown, in
Port 26.
Link Status (Read-Only)
Indicates whether or not there is a physical connection from this port to
another 10BASE-F or 100BASE-TX/FX device. One of the following
values is displayed:
•
Link – There is a link signal present and a valid physical connection
to another 10BASE-F or 100BASE-TX/FX device.
•
No Link – There is no link signal present and there is no valid physical
connection to another device.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-75
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Current Oper. Mode (Read-only)
This field displays the current operating mode of ports 25 and 26.
Depending on the interface installed (100BASE-FX or 100BASE-TX)
this field displays the following:
•
With a 100BASE-FX interface: 100Base-FX or 100Base-FXFD (full
duplex).
•
(full duplex), 100Base-TX, or 100Base-TXFD (full duplex).
Desired Oper. Mode (Selectable)
This field allows the user to select the desired operational mode for an
interface in port 25 or 26. The field toggles between 100BASE-FX and
100BASE-FXFD (full duplex) when an FE-100FX or FE-100F3 is
installed. Section 5.22.1 describes how to configure a port with an
FE-100FX or FE-100F3.
In normal operation, the port with an FE-100TX installed
automatically establishes a link with the device at the other end
NOTE
of the segment without requiring user setup. However, Local
Management provides the user with the option of manually
configuring that port.
If an FE-100TX is installed, the field steps to Auto-Negotiation,
10BASE-T, 10BASE-TFD (full duplex), 100BASE-TX, and
100BASE-TXFD (full duplex). In normal operation, the port with an
FE-100TX installed is capable of auto-negotiating the operational mode
and no further user setup is required. Section 5.22.3 describes how to
configure an FE-100TX.
5-76
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
High Speed Interface Configuration Menu Screen (6E12X-26 Only)
Advertised Ability (Selectable)
During auto-negotiation, the FE-100TX “tells” the device at the other end
of the segment what its capabilities are. The capabilities of a port (25 or
26) with an FE-100TX installed are 10BASE-T, 10BASE-TFD (full
In normal operation, with all capabilities enabled, the FE-100TX
“advertises” that it has the ability to operate in any mode. The Network
Manager may choose to set up the port so that only a portion of the
available capabilities are advertised and the others are disabled. For
example, only 100BASE-TX and 100BASE-TXFD might be enabled so
that only devices that operate at 100 Mbps can communicate with that
5.22.1 Configuring an FE-100FX or FE-100F3
in Port 25 or 26
When an FE-100FX or FE-100F3 is installed in port 25 or 26, it must be
manually set to operate in the same technology as the device at the other
end of the connected segment. Section 5.22.2 provides instructions for
manually configuring the port with an FE-100FX or FE-100F3 interface.
5.22.2 Setting the FE-100FX and FE-100F3
Operational Mode
Use this field to set the active technology. This field toggles between
100BASE-FX and 100BASE-FXFD (full duplex). To set the active
technology through Local Management, proceed as follows:
1. Use the arrow keys to highlight the Desired Oper. Mode field.
2. Use the SPACE bar to select 100Base-FX or 100Base-FXFD (full
duplex).
3. Press ENTER. The port now operates in the chosen mode.
4. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “SAVED OK” displays and Local Management saves
the changes to memory.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-77
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.22.3 Configuring an FE-100TX in Port 25 or 26
In normal operation, a port (25 or 26) with an FE-100TX interface
automatically establishes a link with the device at the other end of the
segment and no user setup is required. Section 5.22.4 and Section 5.22.5
provide instructions for manually configuring the port with an FE-100TX
installed.
5.22.4 Setting the FE-100TX Operational Mode
Use this field to set the active technology. This field steps between
Auto-Negotiation, 10BASE-T, 10BASE-TFD (full duplex),
100BASE-TX, and 100BASE-TXFD (full duplex). If Auto-Negotiation is
selected, the FE-100TX automatically sets the active technology. To
manually set the active technology through Local Management, proceed
as follows:
1. Use the arrow keys to highlight the Desired Oper. Mode field.
2. Use the SPACE bar to select the desired mode. Press ENTER. If any
mode other than Auto-Negotiation is selected, the port only operates
in the chosen mode and auto-negotiation is disabled.
3. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “SAVED OK” displays and Local Management saves
the changes to memory. The selected mode is displayed in both the
Desired Operational Mode field and the Current Operational Mode
field.
5.22.5 Setting the FE-100TX Advertised Ability
In normal operation, a port (25 or 26) with an FE-100TX auto-negotiates
to the highest speed possible. Under some circumstances, the Network
Administrator may want the port to advertise only some of the available
modes and not operate in other modes. This field steps between
10BASE-T, 10BASE-TFD (full duplex), 100BASE-TX, and
100BASE-TXFD (full duplex). To set the advertised ability, proceed as
follows:
1. Use the arrow keys to highlight the Desired Oper. Mode field.
2. Use the SPACE bar to select the desired mode.
5-78
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Download Screen
3. Use the LEFT-ARROW key to move back to the Advertised Ability
selection and use the SPACE bar to select the next mode to enable or
disable.
4. Use the RIGHT-ARROW key to move across to the
Enabled/Disabled field to the right of the selection.
5. Use the SPACE bar to select Enabled or Disabled. Press ENTER.
Continue this process until you have completed enabling or disabling
the advertised modes.
6. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “SAVED OK” displays and Local Management saves
the changes to memory.
The Flash Download screen, shown in Figure 5-29, allows the user to
clear the information stored in the 6E12X-26 and 6E13X-25 FLASH
memory and download a new image file from a TFTP server.
The user may also force a download by changing the position
of Switch 6 located inside the module. Refer to Section C.2,
NOTE
Setting the Mode Switch, for details.
Before downloading a new image to the module, load the image onto the
network TFTP server.
For information on how to set up a workstation as a TFTP
server, refer to the specific workstation documentation.
NOTE
Access the Flash Download screen from the Module Specific
Configuration screen by using the arrow keys to highlight the FLASH
DOWNLOAD menu item and pressing ENTER. The Flash Download
screen displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-79
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
TFTP DOWNLOAD. WILL COMMIT TO FLASH. REBOOT IN PROGRESS...
6E122-26 LOCAL MANAGEMENT
Flash Download
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Download Method:
Reboot After Download:
TFTP Gateway IP Addr:
Last Image Server IP:
Last Image File Name:
Download Server IP:
Download File Name:
[TFTP]
[YES]
134.141.79.123
134.141.79.121
RETURN
/tftpboot/6E122.hex
134.141.79.121
/tftpboot/6E122.hex
EXECUTE
EXIT
RETURN
1960_49
Figure 5-29 Flash Download Screen
Download Server IP and Download Server Filename are
displayed only when TFTP or RUNTIME are selected in
Download Method.
NOTE
The following briefly explains each field of the Flash Download screen:
Download Method (Selectable)
BOOTP, the module sends out a BootP request to determine the IP
address of the TFTP server and the filename of the image to be
downloaded. If set for TFTP or RUNTIME, the 6E12X-26 and 6E13X-25
attempts a TFTP download based on the IP address and filename entered
in the fields at the bottom of the Flash Download screen. Section 5.23.1
describes how to download using TFTP. Section 5.23.2 describes how to
download using RUNTIME. Section 5.23.3 describes how to download
using BootP.
5-80
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Download Screen
Reboot After Download (Modifiable when RUNTIME is chosen only)
This field notifies the user that the 6E12X-26 and 6E13X-25 will reboot
after the download is complete. If a RUNTIME Download is performed,
this field toggles between YES and NO. If YES is selected, the module
reboots after the download is completed. If NO is selected the module
continues using the existing the firmware image. The module stores the
chassis is reset, the module will boot from FLASH memory using the new
image.
TFTP Gateway IP Addr (Selectable)
This field shows the IP address of the TFTP gateway server defined in the
General Configuration screen in Section 5.15.4, Setting the TFTP
Gateway IP Address.
Last Image Server IP (Read-only)
This field shows the IP address of the server used for the previous FLASH
Download.
Last Image File Name (Read-only)
This field shows the complete path and file name of the last image
downloaded to FLASH.
If TFTP or RUNTIME is selected as the download method
(Figure 5-29), the following two additional fields appear:
Download Server IP (Selectable)
The IP address of the TFTP server to be used for the FLASH download is
entered in this field.
Download File Name (Selectable)
The complete TFTP Server path and file name of the new image is entered
in this field.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-81
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.23.1 Image File Download Using TFTP
Set the 6E12X-26 and 6E13X-25 to download to FLASH using TFTP as
follows:
1. Use the arrow keys to highlight the Download Method field.
2. Use the SPACE bar to select TFTP.
3. Use the arrow keys to highlight the TFTP Gateway IP Addr field.
4. Set the IP address of the TFTP gateway server (this defaults to the
same IP address as that set in the TFTP Gateway IP Addr field on the
General Configuration screen).
5. Use the arrow keys to highlight the Download Server IP field.
6. Enter the IP address of the TFTP server using the DDN format.
For example: 134.141.79.121
7. Use the arrow keys to highlight the Download File Name field.
8. Enter the complete pathway and file name of the image stored on the
download server.
For example: /tftpboot/6E128.hex
9. Use the arrow keys to highlight EXECUTE at the bottom of the screen
and press ENTER. The message “TFTP DOWNLOAD. WILL
COMMIT TO FLASH. REBOOT IN PROGRESS...” displays in the
event message line at the top of the screen and the new image is
downloaded into FLASH memory.
5-82
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Download Screen
5.23.2 Image File Download Using RUNTIME
Set the 6E12X-26 and 6E13X-25 to download to FLASH using
RUNTIME as follows:
1. Use the arrow keys to highlight the Download Method field.
2. Use the SPACE bar to select RUNTIME.
3. Use the arrow keys to highlight the Reboot After Download field.
4. Use the SPACE bar to select either YES or NO. Select YES if you
want the module to reboot after the download is completed. Select NO
if you want the module to store the new image in FLASH memory
until the module is manually reset.
5. Use the arrow keys to highlight the TFTP Gateway IP Addr field.
6. Set the IP address of the TFTP gateway server (this defaults to the
same IP address as that set in the TFTP Gateway IP Addr field on the
General Configuration screen).
7. Use the arrow keys to highlight the Download Server IP field.
8. Enter the IP address of the TFTP server using the DDN format.
For example: 134.141.79.121
9. Use the arrow keys to highlight the Download File Name field.
10. Enter the complete pathway and file name of the image stored on the
download server.
For example: /tftpboot/6E128.fls
11. Use the arrow keys to highlight EXECUTE at the bottom of the screen
and press ENTER. The message “RUNTIME DOWNLOAD. WILL
COMMIT TO FLASH.” displays in the event message line at the top
of the screen and the new image is downloaded into FLASH memory.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-83
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.23.3 Image File Download Using BootP
Set the 6E12X-26 and 6E13X-25 to download to FLASH using BootP as
follows:
1. Use the arrow keys to highlight the Download Method field.
2. Use the SPACE bar to select BOOTP.
3. Use the arrow keys to highlight the TFTP Gateway IP Addr field. Set
the IP address of the TFTP gateway server (this defaults to the same
IP address set in the TFTP Gateway IP Addr field in the General
Configuration screen).
4. Use the arrow keys to highlight EXECUTE at the bottom of the screen
and press ENTER. The message “BOOTP DOWNLOAD. WILL
COMMIT TO FLASH. REBOOT IN PROGRESS...” displays in the
event message line at the top of the screen and the new image is
downloaded into FLASH memory.
5-84
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Redirect Function Screen
5.24 PORT REDIRECT FUNCTION SCREEN
The Port Redirect Function screen may not be available
depending on the operational mode that has been set for the
module. Refer to your Release Notes to see what operational
modes support the Port Redirect Function. Refer to
NOTE
Section 5.15.9, Setting the Operational Mode, for instructions
on configuring the operational mode of the module.
The Port Redirect Function screen, Figure 5-30, allows the user to set
each one of the ports on the 6E12X-26 and 6E13X-25 as a source or
destination port. A port can be set to have one or more destination ports.
For example, port 1 can be set as a source port with three destinations,
ports 2, 3, and 4. Traffic from port 1 is then automatically redirected to
ports 2, 3, and 4. Port 1 can also serve as a destination port for other ports.
The port redirect function is extremely useful for troubleshooting
purposes, as it allows traffic to be sent to a particular port(s) where, with
the use of an analyzer or RMON probe, all current traffic from the source
port(s) can be examined.
Although all traffic from the source port (including, if desired,
errored frames) is sent to the destination port, normal switching
NOTE
is still performed for all frames on the source port.
Access the Port Redirect Function screen from the Module Specific
Configuration Menu screen by using the arrow keys to highlight the
PORT REDIRECT FUNCTION menu item and pressing ENTER. The
Port Redirect Function screen displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-85
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Event Message Line
6E122-26 LOCAL MANAGEMENT
Port Redirect Function
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Source Port:
Destination Port:
============
Remap Errors:
============
============
1
1
1
2
2
3
3
3
2
3
4
1
3
4
5
6
ON
ON
ON
OFF
OFF
ON
ON
ON
Source Port [1]
Destination Port [1]
Errors [ON]
Status [ADD]
RETURN
RETURN
PREVIOUS
SAVE
NEXT
EXIT
1960_22
Figure 5-30 Port Redirect Function Screen
The following definitions briefly explain each field of the Port Redirect
Function screen:
Source Port (Read-only)
Shows which ports are currently set as source ports.
Destination Port (Read-only)
Shows which ports are currently set as destination ports.
Remap Errors (Read-only)
Displays whether the corresponding source ports are configured to send
errored frames to the destination ports, or to drop all errored frames
before forwarding traffic.
Source Port [n] (Selectable)
Allows a selected port [n] to be changed to a source port.
Destination Port [n] (Selectable)
Allows a selected port [n] to be changed to a destination port.
5-86
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Redirect Function Screen
Errors (Toggle)
Allows the user to configure the source ports to either send errored frames
to selected destination ports, or to drop errored frames, and send only
valid traffic to the destination ports. The default setting of this field is
[ON].
Status (Selectable)
Allows you to add or delete the source and destination ports selected in
the Source Port [n] and Destination Port [n] fields.
5.24.1 Displaying the Source and Destination Entries
There can be more than one Port Redirect Function screen depending on
the number of port redirect entries. Each screen displays up to 10 port
redirect entries. If there is more than one screen of redirect entries, the
NEXT and/or PREVIOUS command is displayed at the bottom of the
screen, allowing the user to navigate to either the next or previous screen.
To display the next screen, use the arrow keys to highlight NEXT. Press
ENTER and the next screen of entries is displayed.
To display the previous screen, use the arrow keys to highlight
PREVIOUS. Press ENTER to view the entries in the previous screen.
5.24.2 Changing Source and Destination Ports
Add or delete source port and destination port entries as follows:
1. Use the arrow keys to highlight the Source Port field.
2. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the port number displayed in the brackets [n] until the
appropriate port number is displayed.
3. Use the arrow keys to highlight the Destination Port field.
4. Use the SPACE bar or BACKSPACE to step to the appropriate port
number for the destination port.
5. Use the arrow keys to highlight the Status field.
6. Use the SPACE bar to select either the ADD or DEL (delete) option.
Press ENTER. This adds or deletes the port selections made in steps 2
and 4 and also updates the screen Source Port and Destination Port list.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-87
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
7. Use the arrow keys to highlight the Errors field.
8. Use the SPACE bar to select either the ON or OFF option and press
ENTER. ON forces the source module and port to forward errored
frames to the destination module(s) and port(s). OFF forces the
errored frames to be dropped before forwarding traffic.
If more than one port is to be redirected, repeat steps 1 through
8 for each additional setting, then go to step 9 to save all the
NOTE
new settings at once.
9. Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” is displayed. This saves
the new settings and updates the Source Interface and Destination
Interface read-only fields.
5-88
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Broadcast Suppression Screen
5.25 BROADCAST SUPPRESSION SCREEN
desired limit of receive broadcast frames per port per second.
The Broadcast Suppression screen may not be available if the
operational mode of the module has been set to SECURE
NOTE
FAST VLAN or 802.1Q SWITCHING. Refer to your Release
Notes to see what operational modes support Broadcast
Suppression. Refer to Section 5.15.9, Setting the Operational
Mode, for instructions on configuring the operational mode of
the module.
Any broadcast frames received above the desired threshold will
be dropped.
Access the Broadcast Suppression screen from the Module Specific
Configuration screen by using the arrow keys to highlight the
BROADCAST SUPPRESSION menu item and pressing ENTER. The
Broadcast Suppression screen displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
Broadcast Suppression
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
PORT #
Total RX
Peak Rate
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
Time Since Peak
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
999:23:59
Threshold
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
150000
Reset Peak
[NO]
1
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
12345678910
2
[NO]
3
[NO]
4
[NO]
5
[NO]
6
[NO]
7
[NO]
8
[NO]
9
[NO]
10
11
12
[NO]
[NO]
[NO]
RETURN
RETURN
SAVE
[13-24]
EXIT
1960_56
Figure 5-31 Broadcast Suppression Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-89
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
The following explains each field of the Broadcast Statistics screen:
PORT # (Read-only)
Identifies the number of the port.
Total RX (Read-Only)
Displays the total number of broadcast frames received.
Peak Rate (Read-Only)
Displays the number of broadcast frames received per second.
Time Since Peak (Read-Only)
Displays the time since peak broadcast frames received.
Threshold (Modifiable)
Allows the user to set the desired limit of receive broadcast frames that
will be forwarded per port per second.
Reset Peak (Modifiable)
Allows the user to reset the peak rate. Resetting the Peak Rate also resets
the Time Since Peak field. The Reset Peak field toggles betweenYES and
NO.
[1-12], or [13-24] (Navigation Key)
When the Broadcast Statistics screen displays, the current statistics are
displayed for the first 12 ports. This field allows the user to step to a
second screen for the same type of information for ports 13 through 24.
While on the second screen, the user can navigate back to the first screen
by selecting the [1-12] option. The user can change the Threshold or
Reset Peak Rate fields while in the first or second screen.
5.25.1 Setting the Threshold
To set the Threshold, proceed as follows:
1. Use the arrow keys to highlight the Threshold field for the selected
port.
2. Type in the numbers for the desired limit in increments of 10.
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
5-90
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Module Statistics Menu Screen
5.25.2 Setting the Reset Peak Switch
To set the Reset Peak Switch field to YES or NO, proceed as follows:
1. Use the arrow keys to highlight the Reset Peak field for the selected
port.
2. Press the SPACE bar to select YES or 3NO.
3. Use the arrows keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” is displayed.
5.26 MODULE STATISTICS MENU SCREEN
The Module Statistics Menu screen, Figure 5-32, provides access to
screens that allow the user to obtain switch statistics about frame traffic
through each interface, to view MIB-II statistics from each interface, and
to view RMON Statistics gathered by the RMON agent embedded in the
6E12X-26 and 6E13X-25.
The following menu item on the Module Statistics Menu screen
will not display if the operational mode of the module has been
NOTE
set to SECURE FAST VLAN:
SWITCH STATISTICS
Section 5.15.9 provides instructions on setting the operational
mode.
Access the Module Statistics Menu from the Module Menu screen by
using the arrow keys to highlight the MODULE STATISTICS menu
item and pressing ENTER. The Module Statistics Menu screen displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-91
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Event Message Line
6E122-26 LOCAL MANAGEMENT
Module Statistics Menu
Module Type: 6E122-26
Slot Number:
Firmware Revision:
XX.XX.XX
X
BOOTPROM Revision: XX.XX.XX
SWITCH STATISTICS
INTERFACE STATISTICS
RMON STATISTICS
RETURN
EXIT
22511-67
Figure 5-32 Module Statistics Menu Screen
The Module Statistics Menu screen displays the following menu items:
SWITCH STATISTICS
The Switch Statistics screen lists the number of frames received,
transmitted, filtered, and forwarded by each interface.
INTERFACE STATISTICS
The Interface Statistics screen provides the MIB-II statistics for each
switched interface, on an interface-by-interface basis.
RMON STATISTICS
The RMON Statistics screen displays all the statistics gathered by the
embedded RMON agent built-in to the 6E12X-26 and 6E13X-25.
5-92
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Switch Statistics Screen
5.27 SWITCH STATISTICS SCREEN
The Switch Statistics screen, Figure 5-33, lists the number of frames
received, transmitted, filtered, and forwarded by each interface, including
backplane interfaces.
The Switch Statistics screen will not be available if the
operational mode of the module has been set to SECURE
NOTE
FAST VLAN. This screen may only be used by modules
configured to operate as traditional or 802.1Q switches.
Access the Switch Statistics screen from the Module Statistics Menu
screen by using the arrow keys to highlight the SWITCH STATISTICS
menu item and pressing ENTER. The Switch Statistics screen displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
Switch Statistics
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Interface #
Frames Rcvd
Frames Txmtd
100
Frames Fltrd
Frames Frwded
1
2
100
100
100
100
100
100
100
100
100
100
100
100
0
0
0
0
0
0
0
0
0
0
0
0
100
100
100
100
100
100
100
100
100
100
100
100
100
3
100
4
100
5
100
6
100
7
100
8
100
9
100
10
11
12
100
100
100
[13-24]
CLEAR COUNTERS
EXIT
RETURN
1960_26
Figure 5-33 Switch Statistics Screen
The Switch Statistics screen displays the following menu items:
Interface # (Read-Only)
Identifies the interface or port number.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-93
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Frames Rcvd (Read-Only)
Displays the number of frames received by the interface.
Frames Txmtd (Read-Only)
Displays the number of frames transmitted by the interface.
Frames Fltrd (Read-Only)
Displays the number of frames filtered by the interface.
Frames Frwded (Read-Only)
Displays the number of frames forwarded by the interface.
[1-12], [13-24], or [25-26] (6E12X-26), [25] (6E13X-25) (Selectable)
When the Switch Statistics is displayed, the statistics are displayed for the
first 12 ports. These fields allow the user to step to a second or third
25 and 26 of the 6E12X-26 and port 25 (HSIM) of the 6E13X-25. While
on the second or third screen, the user can navigate back to earlier screens
by highlighting the [1-12] and/or [13-24] fields and pressing ENTER.
CLEAR COUNTERS (Command)
This command is used to reset all statistic counters to zero. For details on
how to use this field, refer to Section 5.27.1.
5.27.1 Using the Clear Counters Command
To reset all the statistics counters to zero, perform the following steps:
1. Use the arrow keys to highlight the CLEAR COUNTERS field.
2. Press ENTER, the counters for the selected port are reset to zero.
5-94
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The Interface Statistics Screen
5.28 THE INTERFACE STATISTICS SCREEN
The Interface Statistics screen is used to gather MIB-II statistics for all of
the 6E12X-26 and 6E13X-25 interfaces (ports 1 through 24 and Fast
Ethernet Interface Modules and all backplane interfaces) with the
exception of an HSIM installed in the 6E13X-25.
Cabletron Systems HSIMs gather their own statistics, and may
be viewed via the Local Management screens of the applicable
NOTE
how to access these screens.
Access the Interface Statistics screen by using the arrow keys to highlight
the INTERFACE STATISTICS menu item on the Module Statistics
Menu screen and pressing ENTER. The Interface Statistics screen,
Figure 5-34, displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
Interface Statistics
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
Name: Ethernet Frontpanel
Interface:
1
InOctets:
7500456
Address:
00-00-00-00-00-00
xx days 00:00:00
UP
InUnicast:
InNonUnicast:
InDiscards:
InErrors:
6789
Last Change:
Admin Status:
Oper Status:
0
0
0
0
0
0
0
0
0
0
DOWN
InUnknownProtos:
OutOctets:
MTU:
1514
Speed:
100000000
OutUnicast:
OutNonUnicast:
OutDiscards:
OutErrors:
Link Status:
NO LINK
Duplex Mode:
STANDARD
OutQLen:
CLEAR COUNTERS
Interface: [XX]
EXIT
RETURN
2269_29
Figure 5-34 Interface Statistics Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-95
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
screen:
Interface (Read-only)
This field displays the Interface number for which statistics are currently
being displayed. Figure 5-34 shows the Interface field displaying 1. This
represents port 1 of the module. To view other interface statistics, refer to
Section 5.28.1.
Name (Read-only)
The Name field displays the type of interface for which statistics are
being displayed.
InOctets (Read-only)
This field displays the total number of octets (bytes) that have been
received on the interface. This includes all octets from bad frames, and
framing characters.
InUnicast (Read-only)
The InUnicast field displays the total number of frames that have been
received that were sent to a single address.
InNonUnicast (Read-only)
This field displays the total number of frames that have been received that
were delivered to a broadcast or multicast address.
InDiscards (Read-only)
The InDiscards field displays the total number of inbound frames that
were discarded, even though the frames contained no errors. This field
may increment because the switch needed to free up buffer space, or the
switch was being overutilized.
InErrors (Read-only)
This field displays the total number of inbound frames that have been
discarded because they contained errors. This field represents the total
number of errored frames, regardless of the cause of the error.
InUnknownProtos (Read-only)
The InUnknownProtos field displays the total number of frames that were
discarded because the frames were in an unknown, or unsupported,
format.
5-96
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The Interface Statistics Screen
OutOctets (Read-only)
This field displays the total number of octets (bytes) that have been
transmitted from the interface.
OutUnicast (Read-only)
The OutUnicast field displays the total number of packets transmitted that
were sent to a single address.
OutNonUnicast (Read-only)
This field displays the total number of frames transmitted to a broadcast
or multicast address.
OutDiscards (Read-only)
The OutDiscards field displays the total number of outbound frames that
were discarded, even though the frames contained no errors. This field
may increment, because the switch needed to free up buffer space, or the
switch was being overutilized.
OutErrors (Read-only)
This field displays the total number of outbound frames discarded
because they contained errors. This field represents the total number of
errored frames, regardless of the cause of the error.
OutQLen (Read-only)
The OutQLen field displays the length of the packet queue. The field
represents the total number of packets that can be contained in the queue.
Address (Read-only)
This field displays the MAC Address of the interface that is currently
being displayed.
Last Change (Read-only)
This field displays the last time that the interface was reset.
Admin Status (Read-only)
This field displays the current status of the interface. If this field displays
“Testing”, no frames may be passed on this interface.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-97
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Oper Status (Read-only)
This field displays the current status of the interface. If this field displays
“Testing”, no frames may be passed on this interface.
MTU (Read-only)
The MTU field displays the maximum frame size (in octets) that a frame
may contain to be received or transmitted from this interface.
Speed (Read-only)
The Speed field displays the theoretical maximum amount of bandwidth
that the interface can support in bits per second.
Link Status (Read-only)
This field displays the current link status of the interface. This field will
read either “Link” or “No Link”.
Duplex Mode (Read-only)
This field indicates whether the interface is operating in normal or full
duplex mode. This field will read either “Standard” or “Full Duplex”.
Interface [XX] (Command)
This command is used to enter an interface number for viewing statistics.
For instructions on how to use this command, refer to Section 5.28.1.
CLEAR COUNTERS (Command)
This command is used to reset all statistic counters to zero. For details on
how to use this field, refer to Section 5.28.2.
5.28.1 Displaying Interface Statistics
To display the statistics for any interface, proceed as follows:
1. Use the arrow keys to highlight the Interface [XX] field at the bottom
of the screen.
2. Press the SPACE bar to increment (or press the DEL (delete) key to
decrement) the interface number.
3. Press ENTER (neither the Interface # fields nor the statistics will
change until ENTER is pressed).
5-98
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
RMON Statistics Screen
5.28.2 Using the Clear Counters Command
To reset all the statistics counters of the selected interface to zero, perform
the following steps:
1. Use the arrow keys to highlight the CLEAR COUNTERS command.
2. Press ENTER, the counters for the selected interface are reset to zero.
5.29 RMON STATISTICS SCREEN
RMON statistics for each interface, on a interface-by-interface basis, are
viewed through the RMON Statistics screen shown in Figure 5-35.
Access the RMON Statistics screen by using the arrow keys to highlight
the RMON STATISTICS menu item on the Module Statistics Menu
screen and pressing ENTER. The RMON Statistics screen displays.
Event Message Line
6E122-26 LOCAL MANAGEMENT
RMON Statistics
Module Type: 6E122-26
Firmware Revision:
XX.XX.XX
Slot Number: X
BOOTPROM Revision: XX.XX.XX
RMON Index:
Data Source:
X
Owner: monitor
Status: valid
IfIndex.1
Drop Events:
Collisions:
0
0
0
0
0
0
0
0
0
Total Packets:
Total Octets:
64 Octets:
0
0
0
0
0
0
0
0
Broadcast Pkts:
Multicasts:
65
-
127 Octets:
255 Octets:
511 Octets:
1023 Octets:
CRC Align Errors:
Undersized Pkts:
Oversized Pkts:
Fragments:
128
256
512
-
-
-
1024 - 1518 Octets:
Jabbers:
CLEAR COUNTERS
Index: [XX]
EXIT
RETURN
2269_65
Figure 5-35 RMON Statistics Screen
The RMON Statistics screen provides statistics for all front
panel Ethernet interfaces, and any Fast Ethernet Interface
Modules installed in the 6E12X-26. RMON Statistics are not
gathered for an HSIM installed in the 6E13X-25.
NOTE
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-99
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
The following definitions explain each field of the RMON Statistics
screen:
RMON Index (Read-only)
This field displays the current Ethernet interface for which statistics are
being shown. The 6E12X-26 and 6E13X-25 have an embedded RMON
agent that gathers statistics for each interface on the module.
Data Source (Read-only)
This field displays the source of the statistics data that is currently being
displayed on the screen. Figure 5-35 shows that the data source for this
RMON index is Interface 1 (port 1) by displaying the name IfIndex.1. If
the screen was displaying RMON statistics for Interface 22 (port 22), the
name displayed would be IfIndex.22.
Owner (Read-only)
This field displays the name of the entity that configured this entry.
Status (Read-only)
The Status field displays the current operating status of the displayed
interface. This field will display “Valid” or “Invalid”.
Drop Events (Read-only)
This field displays the total number of times that the RMON agent was
forced to discard frames due to the lack of available switch resources.
The Drop Events field does not display the number of frames
dropped, it only displays the number of times that the RMON
NOTE
agent was forced to discard frames.
Collisions (Read-only)
This field displays the total number of collisions that have occurred on
this interface.
Broadcast Pkts (Read-only)
The Broadcast Pkts field displays the total number of good frames that
were directed to the broadcast address. The value of this field does not
include multicast frames.
5-100
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
RMON Statistics Screen
Multicasts (Read-only)
The Multicasts field displays the total number of good frames received
that were directed to a multicast address. The value of this field does not
include frames directed to the broadcast address.
CRC Align Errors (Read-only)
This field displays the number of frames with bad Cyclic Redundancy
Checks (CRC) received from the network. The CRC is a 4-byte field in
the data frames that ensures that the data received is the same as the data
that was originally sent.
Undersized Pkts (Read-only)
The Undersized Pkts field displays the number of frames received whose
size was less than the minimum Ethernet frame size of 64 bytes, not
including preamble, but have a valid CRC.
Oversized Pkts (Read-only)
The Oversized Pkts field displays the number of frames received whose
size exceeded 1518 data bytes, not including preamble, but have a valid
CRC.
Fragments (Read-only)
This field displays the number of received frames that are not the
minimum number of bytes in length or received frames that had a bad
Frame Check Sequence (FCS), were less than 64 bytes in length
(excluding framing bits, but including FCS bytes), and have an invalid
CRC.
It is normal for the Fragments field to increment. This is
because the RMON agent increments the field when runts are
NOTE
detected (which are normal occurrences due to collisions) and
when noise hits occur.
Jabbers (Read-only)
This field displays the total number of frames that were greater than 1518
bytes and had either a bad FCS or a bad CRC.
Total Packets (Read-only)
This field displays the total number of frames (including bad frames,
broadcast frames, and multicast frames) received on this interface.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-101
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Total Octets (Read-only)
This field displays the total number of octets (bytes) of data, including
those in bad frames, received on this interface.
64 Octets (Read-only)
Displays the total number of frames including bad frames, received that
were 64 bytes in length (excluding framing bits, but including FCS bytes).
65 - 127 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 65 and 127 bytes in length (excluding framing bits, but
including FCS bytes).
128 - 255 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 128 and 255 bytes in length (excluding framing bits, but
including FCS bytes).
256 - 511 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 256 and 511 bytes in length (excluding framing bits, but
including FCS bytes).
512 - 1023 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 512 and 1023 bytes in length (excluding framing bits, but
including FCS bytes).
1024 - 1518 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 1024 and 1518 bytes in length (excluding framing bits, but
including FCS bytes).
Index [XX] (Command)
This command is used to enter an index number for viewing statistics. For
instructions on how to use this command, refer to Section 5.29.1.
CLEAR COUNTERS (Command)
This command is used to reset all statistic counters to zero. For details on
how to use this field, refer to Section 5.29.2.
5-102
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
RMON Statistics Screen
5.29.1 Displaying RMON Statistics
To display the statistics for any index, proceed as follows:
1. Use the arrow keys to highlight the Index [XX] field at the bottom of
the screen.
2. Press the SPACE bar to increment (or press the DEL [delete] key to
decrement) the index number.
3. Press ENTER (neither the RMON Index field nor the statistics will
change until ENTER is pressed).
5.29.2 Using the Clear Counters Command
To reset all the statistics counters of the selected interface to zero, perform
the following steps:
1. Use the arrow keys to highlight the CLEAR COUNTERS field.
2. Press ENTER, the counters for the selected index are reset to zero.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-103
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5.30 NETWORK TOOLS
The Network Tools function resides on both the 6E12X-26 and 6E13X-25
and allows the user to access and manage network devices.
Access the Network Tools screen by using the arrow keys to highlight the
NETWORK TOOLS menu item in the Module or Chassis Menu screen
and pressing ENTER. The Network Tools screen displays.
Welcome to Network Tools
-> help
Commands Available to User
Built in Commands:
bridge
ping
defroute
reset
arp
netstat
show
traceroute
telnet
soft_reset
link_trap
atm_stp_state
SPECIAL:
done, quit, or exit - Exit from the Network Tools.
For help with a specific command, type 'help <command>'.
->
090829
Figure 5-36 Network Tools Help Screen
The Network Tools functions are performed using a series of commands.
Entering commands in Network Tools involves typing the command to be
executed at the Network Tools prompt, adding any desired or required
extensions, and pressing ENTER.
There are two categories of commands in the command set.
•
Built-in Commands – Allow the user to access and manage network
devices. The commands are arp, bridge, defroute, netstat, ping,
reset, show, traceroute, soft_reset, telnet, link_trap, and
atm_stp_state.
•
Special Commands – Allow the user to exit from Network Tools. The
commands are done, exit, and quit.
5-104
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
The conventions used in describing the commands in Network
Tools are as follows:
NOTE
Arguments enclosed by [ ] are required.
Arguments enclosed by < > are optional.
In the following command examples, the information entered by
the user is shown in bold Helvetica font.
To abort the output or interrupt a process, press the CONTROL
key and c key simultaneously, designated as ^C here.
The commands are presented in the following format:
command:
Syntax:
Shows the required command format. It
indicates where arguments, if any, must be
specified.
Description:
Options:
Briefly describes the command and its uses.
Lists any additional fields in the appropriate
format that may be added to the command.
Example:
Shows an example of the command.
5.30.1 Built-in Commands
The built-in commands listed in this section activate functions on the
managed device or devices being accessed through Network Tools.
arp:
Syntax:
arp <options>
Description:
The arp command provides access to the ARP
(Address Resolution Protocol) cache, enabling
you to view cache data, delete entries, or add a
static route. Super-User access is required to
delete an entry or add a static route.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-105
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
Each ARP cache entry lists the network
interface that the device is connected to, the
device’s network address or IP address, the
device’s physical address or MAC address, and
the media type of connection to the device.
Media types are displayed as numbers, which
stand for the following states:
1 - Other
2 - Invalid entry (cannot ping device, timed out,
etc.)
3 - Dynamic route entry
4 - Static route entry (not subject to change)
You can specify the arp command without options, or with one of the
following options:
Options:
-a Views cache data
-d Deletes an IP address entry. Requires
additional arguments: <Interface Number> <IP
address>
-s Adds a static entry. Requires additional
arguments: <Interface Number> <IP address>
<MAC address>
-f Flushes the ARP cache
Example:
-> arp -a
Media Type
3(dynamic)
3(dynamic)
3(dynamic)
3(dynamic)
# Interface
# (SonicInt)
# (SonicInt)
# (SonicInt)
# (SonicInt)
Network Address
122.144.40.111
122.144.48.109
122.144.52.68
122.144.21.43
Physical Address
00.00.0e.12.3c.04
00.00.0e.f3.3d.14
00.00.0e.12.3c.04
00.00.0e.03.1d.3c
-> arp -d 1 122.144.52.68
-> arp -s 1 22.44.2.3 00:00:0e:03:1d:3c
-> arp -f
051467
5-106
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
bridge:
Syntax:
bridge [ENABLE/DISABLE] [IFNUM/ALL]
Description:
The bridge command allows each bridge port to
be enabled or disabled at the user’s request,
either one at a time or all at once. Specifying a
single interface number will affect the bridging
status of that interface, while specifying ALL
will affect every interface.
Options:
Not Applicable
Example:
-> bridge disable all
-> bridge enable 1
-> bridge disable 1
051468
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-107
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
defroute:
Syntax:
defroute [interface number] [IP address]
Description:
The defroute command allows the user to view,
set or delete the default IP route to a managed
device through the specified interface.
Options:
Not Applicable
Example:
-> defroute 2 147.152.42.32
# Default route is 147.152.42.32 on interface 2
-> defroute
# Default route is 147.152.42.32 on interface 2
-> defroute delete
# Default route is not currently set.
->
05141-69
5-108
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
netstat:
Syntax:
netstat [option]
Description:
The netstat command provides a display of
general network statistics for the managed
device. The netstat command must be used with
one of the two display options.
Options:
-i Displays status and capability information for
each interface
-r Displays routing information for each
interface
Example:
-> netstat -i
Speed
Interface + Description
Admin Oper MAC Addr
MTU
10000000
10000000
10000000
10000000
# 1 (ethernet -csmacd)
# 2 (ethernet - csmacd)
# 3 (ethernet - csmacd)
# 4 (ethernet - csmacd)
up
up
up
up
up
up
up
up
0x00 0x00 0x1d 0x07 0x50 0x0e
0x00 0x00 0x1d 0x07 0x50 0x0f
0x00 0x00 0x1d 0x07 0x50 0x10
0x00 0x00 0x1d 0x07 0x50 0x11
1514
1514
1514
1514
-> netstat -r
Destination
Next-hop
Interface
# Default Route
# 134.141.0.0
# 134.141.0.0
DirectConnection
DirectConnection
DirectConnection
1
2
3
051470
ping:
Syntax:
ping [IP address]
Description:
The ping command generates an outbound ping
request to check the status (alive/not alive) of a
device at a specified IP address.
Options:
Not Applicable
Example:
-> ping 122.144.40.10
122.144.40.10 is alive
051471
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-109
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
reset:
Syntax:
reset
Description:
The reset command allows a soft reset of the
device. The user will be queried to confirm the
reset command to insure against unwanted
resets.
The Network Tools connection to the module will be terminated
upon execution of this command.
!
CAUTION
Options:
Not Applicable
Example:
-> reset
174245
show:
Syntax:
show [PROTOCOL] [TABLE]
Description:
The show command displays information
concerning various components of the device.
Protocols currently supported are IP, IPX,
DECnet, and AppleTalk. Components of those
protocols that are currently supported are ARP
caches, route tables, FIB tables, server tables,
and interface tables. The number of valid
entries in the table will be displayed at the end
of the table display.
5-110
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
Options:
Not Applicable
Example:
-> show Appletalk interfaces
AdminStatus
enabled
disabled
# Interface
# 1
# 2
MTU Forwarding
1500 enabled
1500 disabled
OperStatus
enabled
disabled
Framing
ethernet
ethernet
-> show IP ARP
MediaType
3 (dynamic)
3 (dynamic)
# Interface
# 3
# 4
NetworkAddress
123.456.40.1
123.456.40.30
PhysicalAddress
00:00:1d:04:40:5d
08:00:20:0e:d8:31
174246
traceroute:
Syntax:
traceroute [IP address]
Description:
The traceroute command generates a
TRACEROUTE request to a specified IP
address and provides a display of all next-hop
routers in the path to the device. If the device is
not reached, the command displays all next-hop
routers to the point of failure.
Options:
Not Applicable
Example:
-> traceroute 122.144.11.52
# next-hop[0] : 122.144.60.45
# next-hop[1] : 122.144.8.113
# next-hop[2] : 122.144.61.45
# 122.144.11.52 is alive : 3 hops away.
051477
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-111
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
soft_reset:
Syntax:
soft_reset
Description:
This command restarts the software image,
which restores the user configuration settings
from NVRAM. The user will be queried to
confirm the reset command to ensure against
unwanted resets.
The Network Tools connection to the module will be terminated
upon execution of this command.
!
CAUTION
Options:
Not Applicable
Example:
-> soft-reset
174266
5-112
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
telnet:
Syntax:
telnet [IP address] [Port #]
Description:
The telnet command allows the user to
communicate with another host (that supports
Telnet connections) using the Telnet protocol.
The user must specify the remote host using its
IP address. The [IP address] field is mandatory.
If no Port number is specified, telnet will
attempt to contact the host at the default port.
Options:
[Port #]
Example:
-> telnet 134.141.12.345
Trying 134.141.12.345
Connected to 134.141.12.345
SunOS UNIX (server1)
login:
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-113
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
link_trap:
Syntax:
link_trap [enable/disable/status] [PORT/all]
Description:
The link_trap command allows link traps to be
enabled or disabled when specifying a single
port, or simultaneously when specifying “all”
or no ports. When one or all ports are specified
to enable, disable, or find their status, their
current condition is displayed.
Options:
Not Applicable
Example:
-> link_trap status
LINK TRAP STATUS:
Port 1 is ENABLED
Port 3 is ENABLED
Port 2 is DISABLED
Port 4 is ENABLED
-> link_trap disable 2
Link traps have been DISABLED on port 2
-> link_trap disable all
Link traps have been DISABLED on all ports (1-24)
-> link_trap status 3
Link traps are ENABLED on port 3
atm_stp_state:
The atm_stp_state command is only available if an
HSIM-A6DP is installed in the module (e.g., 6E13X-25). This
command allows the user to enable, disable, or check the
current status of the Spanning Tree Algorithm on all ATM
interfaces.
NOTE
Syntax:
atm_stp_state [STATE]
Description:
The atm_stp_state command allows the user to
enable, disable, or check the status of the
Spanning Tree Algorithm on all ATM
interfaces. The user must specify the STATE
option as enable, disable, or status. The STATE
field is mandatory.
5-114
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tools
Options:
enable, disable, status
Example:
-> atm_stp_state status
Atm Stp is Enabled
-> atm_stp_state disable
-> atm_stp_state enable
5.30.2 Special Commands
done, quit, exit:
Syntax:
done
Description:
The done command enables the user to exit
from Network Tools and return to the Main
Menu screen.
Options:
Not Applicable
Example:
-> done
Connection closed
051472
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-115
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Local Management
5-116
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A
SPECIFICATIONS
This appendix provides operating specifications for the Cabletron
Systems 6E132-25, 6E122-26, 6E133-25 and 6E123-26 Interface
Modules. Cabletron Systems reserves the right to change these
specifications at any time without notice.
A.1 DEVICE SPECIFICATIONS
Processor:
Intel i960 RISC processor control
Dynamic Random Access
Memory (DRAM):
FLASH Memory:
16 MB
4 MB
A.2 PHYSICAL PROPERTIES
Dimensions:
43.87 H x 5.71 W x 27.88 D (cm)
18.28 H x 2.38 W x 11.62 D (in)
2.72 kg (6 lb)
Weight (Unit):
MTBF (Predicted):
200,000 hours
A.3 ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
Storage Temperature:
5° to 40°C (41° to 104°F)
-30° to 73°C (-22° to 164°F)
Operating Relative Humidity: 5% to 90% (non-condensing)
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Specifications
A.4 INPUT/OUTPUT PORTS
6E122-26
Ports 1 through 24
Ethernet (10BASE-T compliant) with
RJ45 type connectors.
Slots for optional Fast
Ethernet Interface Modules
(ports 25 and 26)
Slots accept three types of optional
Fast Ethernet Interface Modules: the
FE100-TX, FE100-FX and the
FE-100F3.
6E132-25
Ports 1 through 24
Ethernet (10BASE-T compliant) with
RJ45 type connectors.
Slot for optional HSIM
Slot accepts optional High Speed
Interface Module (HSIM).
6E123-26
Ports 1 through 24
Ethernet (10BASE-T compliant) with
RJ21 type connectors.
Slots for optional Fast
Ethernet Interface Modules
(ports 25 and 26)
Slots accept three types of optional
Fast Ethernet Interface Modules: the
FE100-TX, FE100-FX and the
FE-100F3.
6E133-25
Ports 1 through 24
Ethernet (10BASE-T compliant) with
RJ21 type connectors.
Slot for optional HSIM
Slot accepts optional High Speed
Interface Module (HSIM).
A-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
COM Port Pinout Assignments
A.5 COM PORT PINOUT ASSIGNMENTS
The COM port is a serial communications port that supports Local
Management or connection to a UPS.
The COM port has the following pin assignments:
Table A-1 COM Port Pin Assignments
Pin
Signal Name
Input/Output
1
2
3
4
5
6
7
8
Transmit Data (XMT)
Output
Output
Input
Input
NA
Data Carrier Detect (DCD)
Data Set Ready (DSR)
Receive Data (RCV)
Signal Ground (GND)
Data Terminal Ready (DTR)
Request to Send (RTS)
Clear to Send (CTS)
Output
Input
NA
A.6 REGULATORY COMPLIANCE
Safety
The 6E12X-26 and 6E13X-25 meet the safety requirements of UL 1950,
CSA C22.2 No. 950, EN 60950, IEC 950 and 73/23/EEC.
Electromagnetic Compatibility (EMC)
The 6E12X-26 and 6E13X-25 meet the requirements of FCC Part 15,
EN 50082-1, EN 55022, VCCI V-3, CSA C108.8, AS/NZS 3548, and
89/336/EEC.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Specifications
A-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B
FE-100TX, FE-100FX AND FE-100F3
SPECIFICATIONS
The 6E12X-26 supports three Fast Ethernet Interface Modules:
•
•
•
FE-100TX
FE-100FX
FE-100F3
This appendix provides the specifications for these modules.
B.1 FE-100TX
Unshielded Twisted Pair (UTP) cabling with an impedance between 85
and 111 ohms.
The slide switch on the FE-100TX determines the crossover status of the
cable pairs. If the switch is on the X side, the pairs are internally crossed
over. If the switch is on the = side, the pairs are not internally crossed
over. Figure B-1 shows the pinouts for the FE-100TX in both positions.
Position X
(crossed over)
Position =
(not crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
5. NC
6. RX-
7. NC
8. NC
1. TX+
2. TX-
3. RX+
4. NC
x
=
10
100
FE-100TX
16651_05
Figure B-1 FE-100TX Pinouts
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications
B.2 FE-100FX
The FE-100FX shown in Figure B-2 uses an SC style connector that
supports multimode fiber optic cabling. Specifications for the FE-100FX
are listed below.
FE-100FX
2 6
2 5
2076_7
Figure B-2 FE-100FX
Table B-1 Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
50/125 µm fiber
62.5/125 µm fiber
100/140 µm fiber
6.0 dB
9.0 dB
15.0 dB
9.0 dB
12.0 dB
18.0 dB
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
NOTE
B-2
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
FE-100F3
B.3 FE-100F3
The FE-100F3 shown in Figure B-3 uses an SC style connector that
supports single mode fiber optic cabling. Specifications for the FE-100F3
are listed in Table B-2 below.
FE-100F3
2 6
2 5
2076_8
Figure B-3 FE-100F3
Table B-2 Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
8/125 µm fiber
12/125 µm fiber
>10.0 dB
>10.0 dB
<10.0 dB
<10.0 dB
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
NOTE
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications
B-4
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C
MODE SWITCH BANK SETTINGS AND
OPTIONAL INSTALLATIONS
This appendix covers the following items:
•
•
•
Required tools (Section C.1)
Locations, functions, and settings for the mode switches (Section C.2)
Installing Optional Fast Ethernet Interface Modules (Section C.3)
C.1 REQUIRED TOOLS
You need the following tools to perform the procedures provided in this
appendix:
•
•
Antistatic wrist strap (provided with 6C105 chassis)
Phillips screwdriver
C.2 SETTING THE MODE SWITCH
The following procedures may also be performed through Local
Management. The mode switches should only be used if it is
NOTE
not possible to make a Local Management connection. Refer to
Chapter 5, Local Management, for instructions on how to
perform these tasks.
These mode switches are set at the factory and do not need to be changed
unless you intend to perform the following:
•
•
Force download a new image file from a BootP server.
Clear NVRAM and restore all user-entered parameters such as the IP
address and subnet masks to the 6E12X-26 and 6E13X-25 “Default”
configuration settings.
•
Clear user-entered passwords stored in NVRAM and restore the
default passwords.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Mode Switch Bank Settings and Optional Installations
Figure C-1 shows the location of the mode switches and the switch
settings for normal operation.
MODE SWITCH BANK
Flash
OFF ON
1
2
3
4
5
6
7
8
DRAM
Figure C-1 6E12X-26 and 6E13X-25 Mode Switch
Location/Component Layout
Switch definitions and positions are as follows:
•
•
Switches 1 through 4 – For Cabletron Systems use only.
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disablesAutobaud sensing and
sets the COM port to 9600 baud for Local Management sessions.
•
Switch 6 – Forced BootP. Changing the position of this switch (i.e.,
moving the switch from one position to the other) clears download
information from NVRAM and forces the 6E12X-26 and 6E13X-25 to
download a new image file from a BootP server after power to the
chassis is restored, or the RESET button is pressed.
C-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Mode Switch
After changing the position of switch 6, DO NOT reapply power
to the chassis or reset the module until there is a station acting
as a BootP server, which contains the image file.
NOTE
•
Switch 6 – After changing the position of switch 6 and restarting the
module, the 6E12X-26 and 6E13X-25 request a new image download
until they either receive a new image or the RESET button on the front
panel is pressed. When the RESET button is pressed, the 6E12X-26
and 6E13X-25 continue trying to contact a BootP server, but will time
out in approximately one minute. If the module times out, the image is
downloaded from its FLASH memory.
•
•
Switch 7 – Clear NVRAM. Changing the position of this switch resets
NVRAM on either the next power up or the next operation of the front
panel RESET switch. ALL user-entered parameters, such as IP
addresses, subnet masks, SNMP traps, and bridging functions are
restored to their factory default settings.
Switch 8 – Reset Password/Community Strings. Changing the position
of this switch clears only the user-entered passwords stored in
NVRAM, and restores the default passwords. Once the 6E12X-26 and
6E13X-25 are reset, the passwords can either be reentered or the
default passwords (Public and ENTER) may be used.
Do not change the position of switch 8 unless it is necessary to
reset the module super-user configured passwords to their
factory default settings.
NOTE
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Mode Switch Bank Settings and Optional Installations
C.3 INSTALLING OPTIONAL FAST ETHERNET
INTERFACE MODULES
Figure C-2 shows the location of the Fast Ethernet Interface Module
connectors on the 6E12X-26 board for port slots 25 and 26.
For instructions on installing a High Speed Interface Module
(HSIM) in the 6E13X-25, refer to the applicable HSIM
NOTE
documentation.
Optional Fast
Ethernet Interface
Modules
Connectors
Figure C-2 Fast Ethernet Interface Module Connector Location
C-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Optional Fast Ethernet Interface Modules
To install a Fast Ethernet Interface Module in port slot 25 or 26 of the
6E12X-26, proceed as follows:
The Fast Ethernet Interface Module and the host module are
sensitive to static discharges. Use an antistatic wrist strap and
observe all static precautions during this procedure. Failure to
do so could damage the Fast Ethernet Interface Module or the
host module.
!
CAUTION
The FE-100F3 uses Class 1 lasers. Do not use optical
instruments to view the laser output. The use of optical
instruments to view laser output increases eye hazard. When
viewing the output optical port, power must be removed from
the network adapter.
!
CAUTION
1. Remove the coverplate from the port slot where the Fast Ethernet
Interface Module will be installed.
When installing Fast Ethernet Interface Modules in both port
slots 25 and 26, remove the coverplates from both slot
openings. In the following instructions, the optional module is
shown being installed in port slot 26.
TIP
To remove a coverplate, refer to Figure C-3 and proceed as follows:
a. Remove the two screws fastening the coverplate to the standoffs.
Save the screws.
b. Lift and remove the coverplate from the top of the front standoffs.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
C-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Mode Switch Bank Settings and Optional Installations
Coverplate
Rear
Standoff
Front
Standoffs
25
26
Figure C-3 Coverplate Removal
When installing an FE-100FX or FE-100F3 module into the
host module, remove the rubber plug on the SC connector
before proceeding.
!
CAUTION
3. Refer to Figure C-4. Gently pull the faceplate of the host module
forward to allow room for the Fast Ethernet Interface Modules to be
aligned over the connector.
4. Carefully lower the Fast Ethernet Interface Module onto the standoffs
while inserting the module connector into the associated motherboard
connector.
When inserting the Fast Ethernet Interface Module into the
motherboard connector ensure that the pins do not bend, as
this can damage both the Fast Ethernet Interface Module and
the motherboard connector.
!
CAUTION
C-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Optional Fast Ethernet Interface Modules
Module
Module
Connector
10
100
FE-100TX
Rear
Standoff
Motherboard
Connector
Front
Standoffs
25
26
Figure C-4 Installing the Fast Ethernet Interface Module
5. Press down firmly on the Fast Ethernet Interface Module until the pins
slide all the way into the motherboard connector. Ensure that the Fast
Ethernet Interface Module seats flush on the standoffs.
6. Secure the Fast Ethernet Interface Module with the screws saved in
steps 1 and 2.
7. Installation is complete.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
C-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Mode Switch Bank Settings and Optional Installations
C-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Numerics
Clear NVRAM 5-45
Clearing NVRAM 5-56
100BASE-TX
cable length 2-2
10BASE-T
pin assignments A-3
connection 3-6, 3-8
requirements 2-2
5-71
D
A
Access policy 5-25, 5-58
B
5-90, 5-91
C
Cable specifications
5-71
chassis date 5-16
chassis time 5-16
Chassis Uptime 5-17
IP address 5-16
Operational Mode 5-17
screen refresh time 5-16, 5-20
subnet mask 5-16
G
Chassis date 5-16
General Configuration screen 5-41
Clear NVRAM 5-45
Chassis Environmental Screen 5-29
Chassis Environmental screen 5-14
Chassis Menu screen 5-13
Chassis time 5-16
COM port application 5-44
COM port configuration 5-53
default gateway 5-42, 5-47
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
IP address 5-41, 5-45
MAC address 5-41
module date 5-42
module time 5-42, 5-48, 5-49
Module Uptime 5-43
Operational Mode 5-43, 5-51
H
High Speed Interface
Help
related manuals 1-11
Technical Support 1-10
advertised ability 5-77
configuring an FE-100TX 5-78
current operational mode 5-76
desired operational mode 5-76
link status 5-75
Configuration 5-70
System Resources 5-70
Module Statistics Menu screen 5-91
RMON statistics 5-92
port type 5-75
setting the FE-100TX operational
mode 5-78
Module time 5-42
I
Module Uptime 5-43
BOOTP 5-84
RUNTIME 5-83
TFTP 5-82
Network connection
FE-100FX 3-12
Installation
Fast Ethernet Interface Module C-4
Installing into the chassis 3-2
Interface Statistics screen 5-98
IP address 5-16, 5-41, 5-45
IP Fragmentation 5-45, 5-57
FX-100TX 3-10
Network Tools 5-37, 5-104
Network Tools Commands
arp 5-105
atm_stp_state 5-114
bridge 5-107
Index-2
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
defroute 5-107, 5-108
done 5-115
link_trap 5-114
netstat 5-109
Main Menu screen 5-12
ping 5-109
reset 5-110
show 5-110
soft_reset 5-111
telnet 5-113
traceroute 5-111, 5-113, 5-115
O
Operational Mode 5-17
P
Password screen 5-7
Physical properties A-1
Port 5-53
Setting the threshold 5-90
Port Redirect Function 5-14, 5-30,
5-71
R
RESET button 4-7
RMON Statistics screen 5-99, 5-103
S
Safety A-3
5-43, 5-50
Screen refresh time 5-20, 5-50
Screens
Broadcast Suppression screen 5-89
Chassis Environmental
Screen 5-29
Chassis Menu screen 5-13
Ethernet Full Duplex Configuration
screen 5-66
enable traps 5-28
trap community name 5-27
trap destination 5-27
Spanning Tree Algorithm 5-63
Specifications A-1
Standards compatibility 1-6
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Index-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Switch address 5-63
Age Time 5-63
MAC address 5-64
Setting the STA 5-64
State 5-64
Status 5-64
Switch address 5-63
type of STA 5-63
System Resources screen 5-72
current switch utilization 5-73
DRAM installed 5-73
NVRAM installed 5-73
peak switch utilization 5-73
T
TFTP Gateway IP Addr 5-42, 5-48,
5-81
Traps
enable 5-28
Troubleshooting 4-1
checklist 4-6
U
Unpacking 3-1
Index-4
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
|