Warm Mist Humidifiers
FOR THE FOLLOWING MODELS:
EE-5201A
EE-5201W
EE-5201GR
If you have any questions about the operation of
your warm mist humidifier, please contact Crane
Customer Care.
Toll Free: 888-599-0992
Email: [email protected]
PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE
THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE.
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
WARNING! READ AND SAVE THESE INSTRUCTIONS. Failure to follow all the
instructions listed below may result in electric shock, fire and/or serious personal injury.
1. DO NOT carry Water Tank by handle when it is filled with water. It is advisable to
carry filled Water Tank with two hands.
2. DO NOT operate outdoors. This humidifier is intended for indoor use only.
3. DO NOT TOUCH STEAM MIST. Steam can cause burns.
4. DO NOT remove the water tank during operation, or within 15 minutes after the
humidifier is turned off and unplugged. Serious injury may result.
5. DO NOT operate without water. Always have water in the water tank when
operating the unit.
6. Use only clean, cool tap water to fill the tank. DO NOT use hot water.
7. DO NOT pour water into any openings other than the water tank.
8. Do not cover any openings on the unit, or insert objects into any openings.
9. Be sure that the water tank cap is firmly tightened. DO NOT aim mist directly at
children, walls, furniture or electrical appliances.
10.Use only a 110-120VAC outlet. ALWAYS plug and unplug unit with dry hands
to avoid electric shock.
11.Never operate the unit with a damaged cord or plug.
12.Always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and
level surface and position unit away from direct sunlight. Keep the cord away from
heated surfaces and areas where it could be walked on or tripped over. Unplug the
unit when not in use and whenever you clean or move the unit.
13.Do NOT add medication of any type into the Water Basin or Water Tank. Do not
cover any openings on the unit or insert objects into any openings. ONLY add
liquid vapor medicine to the medicine cup include with this humidifier.
14.The unit should not be left unattended in a closed room, as the air could become
saturated and leave condensation on walls or furniture. Leave room door partly
open.
15.The humidifier requires daily and weekly cleaning to operate appropriately. Refer
to cleaning instructions.
16.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner or
other household solvents to clean any part of the humidifier.
17.Do not tilt, tip or attempt to empty or fill the unit while it is in operation.
SAVE THESE INSTRUCTIONS!
2
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL SAFETY INSTRUCTIONS
WARNING! Read and understand all instructions. Failure to follow all instructions
listed below may result in electric shock, fire or serious personal injury. The warnings,
cautions, and instructions discussed in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be understood by the user that
common sense and caution are a factor which cannot be built into this product, but must
be supplied by the user.
THIS HUMIDIFIER IS NOT A TOY!
Do not let your child play with this humidifier. Serious injury and
electrocution might be possible. This humidifier has to be operated by an adult only.
Children should be supervised to ensure that they do not play with the humidifier.
SAVE ALL INSTRUCTIONS!
CAUTION: A short Power Supply Cord is provided to reduce the risk of personal
injury resulting from becoming entangled in or tripping over a longer cord. Extension
cords are available from local hardware stores and may be used if care is exercised in
their use. If an extension cord is required, special care and caution is necessary. Also
the extension cord must be (1) marked with an electrical rating of 125 V and at least 13
A., 1625 W., and (2) the cord must be arranged so that it will not drape over the
countertop or tabletop where it can be pulled on by children or accidently tripped over.
ELECTRIC POWER
If the electric circuit is overloaded by other appliances, your humidifier and/or
appliances may not operate properly. The humidifier should be operated on a separate
electrical circuit from other operating appliances.
POLARIZED PLUG
This humidifier has a polarized plug (one blade is wider than the
other). As a safety feature to reduce the risk of electrical shock, this
plug is intended to fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Do not attempt to defeat this safety
feature.
SAFETY WARNING
Although your humidifier is easy to operate, for your safety, the below warnings must be
followed:
1. Do not place the humidifier near a heat source.
2. Never leave the humidifier unattended while connected to the electrical outlet.
3. To avoid any accidents, never cover the Mist Lid when the humidifier is in operation.
4. Use the humidifier on a smooth, flat, lint-free, non-metallic, waterproof, and level
surface away from water.
5. Do not unplug from the wall socket by pulling on the supply cord.
6. The humidifier must be unplugged:
A. Before either filling or emptying the Water Basin and/or Water Tank.
B. Before any cleaning or maintenance is performed.
C. After each use.
D. If it appears to be faulty.
THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
LIST OF MAIN PARTS
1. Mist Chamber
2. Humidifier Base
3. Water Level Sensor
4. Tip Over Switch (on
bottom of base)
9
1
5. Heating Element
6. Control Knob
7. Indicator Light
8. Reset Button (on
bottom of base)
10
4
2
9. Medicine Cup
10.Water Tank
11.Water Tank Cap
3
5
11
6
8
7
TECHNICAL SPECIFICATIONS:
Rating Voltage
Frequency
120V
60Hz
Power
280W
Water Tank Capacity
Run Time Per Tank
Approx. 1 Gallon
Up to 25 Hours
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION AND USE
BEFORE EACH USE
CHECK HUMIDIFIER PLACEMENT
Place the Humidifier on an elevated, non-metallic, lint-free, waterproof, level surface at
least 2 feet above the floor.
•
•
DO NOT place the humidifier on carpet or a towel. The fan vent is located on the
bottom of the humidifier base. The fan vent MUST NOT be obstructed.
DO NOT place the humidifier on a wood surface or near furniture that can be
damaged by too much moisture.
CHECK WATER LEVEL SENSOR
Make sure that the Water Level Sensor is secured properly and not obstructed.
CAUTION
DO NOT attempt to operate the humidifier without water in the
Water Tank.
DO NOT plug or unplug the Power Cord with wet hands as electric
shock could occur.
ASSEMBLY
CAUTION: DO NOT TOUCH STEAM MIST WHEN HUMIDIFIER IS ON. STEAM
MAY CAUSE BURNS. ALWAYS USE CAUTION!
1. Turn Water Tank upside down and unscrew Water
Tank Cap.
2. Fill Water Tank with cool water. DO NOT fill
water all the way to the rim.
DO NOT CARRY FULL WATER TANK BY
HANDLE. ALWAYS HOLD WATER TANK WITH
TWO HANDS.
DO NOT use hot water. Use cool tap water.
DO NOT add any medication, essential oils, or salt to water. USE ONLY included
medicine cup for liquid vapors.
DO NOT pour water into Mist Channel.
DO NOT overfill medicine cup and allow medication to spill into mist chamber.
3. Screw Water Tank Cap back onto Water Tank. Turn the Water Tank over and place
on Humidifier Base, making sure it fits perfectly.
4. Plug the power cord into a wall socket and turn on the unit by using the Control
Knob. The power light will turn BLUE.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Use the Control Knob to adjust the intensity
of the mist output.
6. When the humidifier runs out of water, the
BLUE power light will turn off, and the mist
ouput will stop. This safety feature uses a
water level sensor to stop the heating
element once the water level sinks below the
required level in the humidifier base. A
small ORANGE light will turn on (light will
appear near the “2” on Control Knob) to
indicate that the humidifier has automatically turned off. Turn the humidifier off and
unplug before removing and refilling the Water Tank.
IMPORTANT: OVERHEAT RED LIGHT
When the humidifier runs out of water, the BLUE light will turn off and mist will stop. If
the unit has overheated, a small RED light will turn on (light will appear near the “2” on
Control Knob). The RED light indicates that the unit has overheated. Turn humidifier off,
unplug the unit, allow humidifier base and water to cool then empty water in humidifier
base. Turn humidifier base over and press the Reset Button, with a pen or pencil tip, on
the bottom of the humidifier base. This will reset the humidifier.
USING THE MIST CHAMBER AND MEDICINE CUP
MIST CHAMBER
1. To remove Mist Chamber, slide Mist
Chamber Latch to left. Carefully lift
Mist Chamber off of Humidifier Base.
2. To attach the Mist Chamber, slide Mist
Chamber Latch to left and place the
Mist Chamber onto Humidifier Base.
Release the latch to secure the Mist
Chamber to Humidifier Base.
NOTE: The humidifier will not operate when
the Mist Chamber is not properly in place.
This is a safety feature which helps to avoid
overheating.
MEDICINE CUP
The Medicine Cup allows the addition of medications recommended for use with warm
mist humidifiers only.
1. Remove the Medicine Cup from the top of the
Mist Channel for easier filling.
2. BE CAREFUL not to overfill the Medicine Cup.
Overfilling may cause medicine to spill into
Mist Channel. Medicine in the Mist Channel
may affect the operation of the humidifier.
3. Place Medicine Cup on top of the Mist Channel.
4. DO NOT add any medication or other additives
directly to the water.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
A NOTE ABOUT HUMIDITY
ꢀ
ꢀ
It is best to keep the humidity level at about 40%-50% of relative humidity.
In cold weather, windows and even some walls may fog or develop frost from
excessive indoor humidity. If this occurs, reduce the mist output setting to avoid
damage from condensed water dripping onto windowsills.
ꢀ
ꢀ
Too much humidity in the room may allow moisture to accumulate on surfaces where
bacteria and fungi can grow. Moisture that gathers may also damage furniture and
walls, especially wallpaper.
To reduce excessive humidity, especially in small rooms, leave the room door open
and adjust the mist intensity control setting.
MAINTENANCE
IMPORTANT: Failure to keep this humidifier clean from mineral deposits normally
contained in any water supply will affect the efficiency of the operation. Customer
failure to follow these instructions may void warranty
DO NOT leave water in Water Tank or Humidifier Base when unit is not in use as it may
result in the buildup of mineral deposits and bacteria that can inhibit the output
efficiency of the humidifier. If water remains in the Water Tank for more than a day or
two, bacterial growth is possible.
DAILY MAINTENANCE
1. Always turn off and unplug from outlet before cleaning.
2. Empty water from the water tank and humidifier base daily.
3. Wipe and dry humidifier base with a clean, dry cloth or paper towel.
4. Replace the water tank.
WEEKLY MAINTENANCE
1. Always turn off and unplug from outlet before cleaning.
2. Empty water from the water tank and humidifier base.
3. Fill the water tank with about a half-gallon of warm water. Add 2 Tablespoons of
white vinegar. Shake vigorously and let sit for 20-30 minutes. Shake vigorously
again and empty the water. Rinse water tank.
4. Make similar white vinegar/water solution. Pour into humidifier base. Let sit for
20-30 minutes, and then empty. Rinse humidifier base. Wipe dry with a clean,
soft cloth.
5. Wipe the exterior surface water tank and humidifier base with a soft, dry cloth.
NEVER IMMERSE HUMIDIFIER BASE IN WATER.
HOW TO CLEAN HEATING ELEMENT
1. Remove the mist chamber.
2. Fill the heating element with undiluted white vinegar.
3. Let stand for 20 minutes. Dampen soft, clean cloth or sponge with undiluted
white vinegar and wipe out heating element to remove scale. DO NOT use soap,
detergents or abrasive cleaners.
4. Rinse heating element using clean warm water, being careful not to submerge
the base in the water. Dry thoroughly. DO NOT IMMERSE WATER BASIN IN
WATER.
5. Soak the removable mist chamber in a solution of ½ white vinegar and ½ water
for 20 minutes. Rinse thoroughly and then wipe dry with a soft clean cloth.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
END-OF-SEASON MAINTENANCE & STORING YOUR HUMIDIFIER
1. Always turn off and unplug from outlet before cleaning.
2. Empty water from the water tank and humidifier base.
3. Disinfect water tank and humidifier base with the white vinegar and water
solution.
4. Make sure that water tank has air dried without the water cap secured.
5. Make sure the humidifier base and water tank are completely dry before end of
season storage. Store the humidifier in a cool dry place.
6. DO NOT place any heavy items on top of humidifier during storage as this may
result in possible damage of the humidifier.
7. Store the cord in a clean, dry location away from metal objects. Always check
the plug before use to ensure metal items have not become attached.
TROUBLE SHOOTING
DO NOT attempt to repair the motor or nebulizer yourself. If the humidifier
continues to not operate please contact Crane Customer Care: 888-599-0992 or
Problem
Solution
If humidifier does not
have any power:
ꢀ
ꢀ
ꢀ
Ensure unit is properly plugged into a power outlet.
Check that the Control Knob is turned to the ON position.
If Power On indicator light does not come on, contact
Crane Customer Care.
Condensation forms
around humidifier and
windows:
ꢀ
ꢀ
Adjust Control Knob to decrease mist output to low.
Leave room door cracked open during humidifier
operation.
If humidifier has
stopped, BLUE light is off
and small RED light is
on:
ꢀ
Adjust Control Knob to turn humidifier off and unplug.
Empty humidifier base, turn over and press Reset Button
on bottom of humidifier.
If there is a strange
odor:
ꢀ
ꢀ
Clean the Water Tank with the water and vinegar solution
and rinse with clean water.
Leave the empty Water Tank open for some time
(without the Water Tank Cap attached) in a cool place.
The power indicator light
is blue, but there is no
mist being emitted:
ꢀ
ꢀ
ꢀ
Check that there is water in the Water Tank.
Make sure that nothing is blocking the mist output.
Check that the Fan Vent on the bottom of the humidifier
is not blocked.
ꢀ
ꢀ
Empty and rinse the Humidifier Base with cool tap water.
Check for possible mineral deposits on the Water Level
Sensor and Heating Element.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CUSTOMER CARE
If you have any questions with regard to the operation of this humidifier
or are in need of a spare part, please contact Crane Customer Care.
Crane USA, Inc.
621 IL Route 83, Suite 202
Bensenville, Illinois 60106
Toll Free: 1-888-599-0992 (Monday - Friday 9:00am - 4:00pm CST)
Email: [email protected]
Website: http://www.crane-usa.com
usa.com.
ENVIRONMENTAL PROTECTION
If the humidifier should no longer operate, please be sure to dispose of
the unit in an environmentally friendly way by taking it into a public
collection point. Please do not place broken humidifiers with your regular
household waste.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Thank you for purchasing a Crane product. This Warm Mist Humidifier was tested
and meets our stringent quality standards. This product is warrantied to be free
from manufacturing defects under normal use and conditions for 1 year.
PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE. CALL US FOR
PROBLEMS AND QUESTIONS. WE CAN HELP.
If you experience unsatisfactory operation, first refer to the troubleshooting
section in the manual to ensure that it is not due to care or cleaning. Follow Care
Customer Care for information.
If you have any questions or comments, please call Crane Customer Care, Toll
the style and model number so our Customer Care Department can assist you.
WARRANTY REQUIRES A DATED PROOF OF PURCHASE.
This warranty is void if the defect is due to accidental damage, misuse, abuse,
neglect, improper repair or alteration by unauthorized persons, or a failure to
follow operating instructions provided with the product. This warranty does not
apply to normal wear and tear or commercial use.
The warranty is non-transferable and applies only to the original purchaser and
does not extend to subsequent owners of the product. Liability under this
warranty is limited to repair or replacement. In no event shall liability exceed the
purchase price paid by the purchaser of the product. Under no circumstances
shall there be liability for any loss - direct, indirect or incidental – or consequential
damage arising out of, or in connection with the use of this product.
This warranty is valid only in the 48 contiguous states plus the District of
Columbia and excludes Puerto Rico and the Virgin Islands. This warranty is
effective only if the product is purchased and operated in the United States of
America.
This warranty gives you specific legal rights; however you may have other rights
that vary from state to state. Some states do not allow limitation on implied
warranties or exclusion of consequential damages; therefore these restrictions
may not apply to you.
Any instructions or warranty included in this manual may be subject to change
without notice. For the most up-to-date instructions and warranty information,
please contact us or visit our website.
To receive warranty instructions and return authorization, please call or email
Crane Customer Care.
Crane USA, Inc.
621 Route 83, Ste 202, Bensenville, Illinois 60106
Toll Free: 1-888-599-0992 (Monday - Friday 9:00am - 4:00pm CST)
Email: [email protected]
Website: http://www.crane-usa.com
10
Download from Www.Somanuals.com. All Manuals Search And Download.
|