INSTALLATION INSTRUCTIONS
HB0091
EC62 SERIES
!
!
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 12.
SV08970 rev. 05
Download from Www.Somanuals.com. All Manuals Search And Download.
- EC62 SERIES POWER PACK SYSTEM -
STANDARD
3¼” X 10” ROOF CAP
(NOT INCLUDED)
STANDARD
3¼” X 10” WALL CAP
(NOT INCLUDED)
MODEL 437
HIGH CAPACITY ROOF CAP
(NOT INCLUDED)
MODEL 441
10” ROUND WALL CAP
(NOT INCLUDED)
MODEL 418
10” ROUND
ADJUSTABLE ELBOW
(NOT INCLUDED)
MODEL 410
10” ROUND DUCT
— 2 FT. SECTIONS
(NOT INCLUDED)
STANDARD
3¼” X 10” DUCT
(NOT INCLUDED)
10” ROUND VERTICAL
IN-LINE DAMPER
(SUPPLIED WITH 1000 CFM
DUAL BLOWER POWER PACK)
10” ROUND ADAPTER
(SUPPLIED WITH 1000 CFM
DUAL BLOWER POWER PACK)
3¼” X 10” ADAPTER/DAMPER
(SUPPLIED WITH SINGLE BLOWER
POWER PACK)
L6230SS,
L6236SS OR L6242SS
CUSTOM HOOD LINER
(OPTIONAL)
L6230SS,
L6236SS OR L6242SS
CUSTOM HOOD LINER
(OPTIONAL)
EC622301SS
POWER PACK
EC621306SS
POWER PACK
HL0126
SINGLE BLOWER
(600 CFM, SUPPLIED
WITH POWER PACK)
DUAL BLOWER
(1000 CFM, SUPPLIED WITH
POWER PACK)
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
1. PREPARE THE INSTALLATION
!
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses
and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the
manufacturer.
Make sure that the following items are included:
- Power Pack
- Accessories: • 2 Filters
• 2 Filter knobs with screws, taped inside the hood
• 2 Shielded halogen lamps (120 V, 50 W max., MR16 with GU10 base)
• 3¼” x 10” adapter and damper (supplied with 600 CFM single blower power pack)
• 10” round in-line vertical damper (supplied with 1000 CFM dual blower power pack)
• 10” round adapter (supplied with 1000 CFM dual blower power pack)
• Bag of parts including: 1 wire clamp, 2 wire connectors, 4 no. 8 x 3/8” screws,
9 no. 8 x 1/2” chrome plated screws, 10 no. 8-32 x 1/4” screws. If need be, discard extra screws.
Parts sold separately:
- Custom hood liner Model L6230SS, L6236SS or L6242SS (optional)
- Ducts, elbows, wall and roof caps. Refer to page 3 for a complete list of venting options and model numbers.
NOTE: During installation, protect countertop and/or cooktop.
2. INSTALL DUCTWORK AND ELECTRICAL WIRING
Plan where and how the ductwork will be installed. Access to the top of the power pack is preferred for connection of ductwork.
Install proper-sized ductwork, elbows and roof or wall cap for the type of power pack you are installing. If installing EC621306SS
single blower power pack, use 3¼” x 10” ductwork. If installing EC622301SS double blower power pack, use 10” round
ductwork. Use 2” metal foil duct tape to seal duct joints.
We recommend to install the power pack at a minimum distance of 24” from an electric range and at 30” from a gas
range.
Distances over 30” are at the installer and users discretion.
Run 3-wire power supply cable to installation location. Its length should extend at least 4 feet below the bottom of the custom
hood.
Roof cap
Roof cap
10” round duct
10” in-line
vertical damper
10” round elbow
10” round adapter
3¼” x 10” duct
3¼” x 10”
adapter & damper
Wall
cap
Power pack
Power pack
Wall
cap
24” minimum above
24” minimum above
cooking surface
cooking surface
(30” for gas range)
(30” for gas range)
HH0116A
HH0117A
MODEL EC621306SS
MODEL EC622301SS
(SINGLE BLOWER) TYPICAL DUCTWORK
(DUAL BLOWER) TYPICAL DUCTWORK
NOTE: Although the horizontal discharge installation is feasible with EC621306SS power pack model, this installation
type should be performed in specific situation only since it requires particular knowledge and technical skills
from the installers.
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
3. PREPARE CUSTOM HOOD
!
WARNING
When building a custom hood, always follow all applicable construction codes and standards. The custom
hood must be positively secured to wall studs or other wooden framework behind the drywall. Make sure
it is capable of supporting its own weight and the weight of the power pack. Failure to do so may cause
personal injury or damage to countertop or cooktop.
The custom hood must be constructed to fit the shape and total weight of the EC62 power pack model. The recommended
minimum thickness for the custom hood base is 5/8”. If an optional custom hood liner will be installed, we recommend the sides
and front of the custom hood to be 3/4” thick. If the optional custom hood liner will not be installed, the custom hood sides and
front thickness are at the installer’s discretion. See chart and illustration for details.
POWER PACK
TYPES
TOTAL
WEIGHT
SINGLE BLOWER
DUAL BLOWER
33 LB
45 LB
SINGLE BLOWER POWER PACK
TOP VIEW
7/8”
5/8”
1¾”
13 5/16”
10½”
5/8”
3 ³/16”
1¾”
10 15/16”
3 ³/16”
10 1/8”
9¾”
2 15/16”
26 5/8”
28 1/8”
13¼”
11/16”
14¾”
HK0104A
BACK VIEW
SIDE VIEW
DUAL BLOWER POWER PACK
NOTE: The dual blower model has the same dimensions than the single blower model, but does not have a horizontal discharge.
Refer to single blower power pack illustration for back and side views, and discard horizontal discharge measurements.
13 5/16”
ø10”
1¾”
7/8”
5¼”
HK0114A
TOP VIEW
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
4. INSTALL CUSTOM HOOD LINER (OPTIONAL)
The liners are specially designed to protect the exterior base of the custom hood. To
order, refer to the table below to find the right liner model number according to the
width of the custom hood nominal width. To view specific model information, including
number listed on front cover).
CUSTOM HOOD
To install, see instruction packed with custom hood
liner.
LINER MODEL
NOMINAL WIDTH
L6230SSS
L6230SSS
L6230SSS
30”
36”
42”
NOTE: The liner must be installed before the insert.
HA0067A
5. CUT THE HOLE IN CUSTOM HOOD BASE
If it is not done yet, cut a hole in the bottom of the custom hood, using the dimensions
shown at right.
13³/8”
NOTE: Keep in mind that the unit exterior flange is 3/4’’.
26¾”
HD0340A
6. REMOVE FILTER
Rest the power pack on a table. Remove tape on filters. Lift filters from power pack by
pushing them towards the back and rotate, then set filters aside.
HD0366
7. UNPLUG THE BLOWER(S)
Unplug the blower(s) (one or two, depending on model) from the front panel.
HE01105
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
8. REMOVE WIRING COVER AND FRONT PANEL
Using a Robertson or a Phillips no. 2 screwdriver, remove both wiring cover
retaining screws (A). Detach it from the power pack and set aside with its screws.
Then, remove both sides screws (B) retaining the front panel to the power pack.
Carefully detach the front panel from the power pack and set aside with its
screws.
A
B
HD0365
9. REMOVE THE ELECTRICAL KNOCKOUT
C
From inside the power pack, punch out the electrical knockout hole on top left
side (C) OR on back left side (D). Install the wire clamp (included in parts bag).
D
HR0030
10. REMOVE THE KNOCK-OUT OPENING (SINGLE BLOWER MODEL ONLY)
Remove the knockout opening on
top (vertical discharge installation)
or on back (horizontal discharge
installation) of the power pack.
1
2
HR0037
11. INSTALL THE ADAPTER/DAMPER (SINGLE BLOWER MODEL ONLY)
VERTICAL DISCHARGE INSTALLATION
Using 2 no. 8 x 3/8’’ screws provided in parts bag,
secure the adapter/damper to the top of the power
pack. Remove tape from damper flap. Seal the
adapter to the power pack using metal foil duct tape.
HO0137
HORIZONTAL DISCHARGE INSTALLATION
The adapter/damper will be installed on the back of the power pack once the power pack will be mounted in the custom hood.
Refer to step 15.
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
12. INSTALL THE ADAPTER AND THE DAMPER (DUAL BLOWER MODEL ONLY)
MOUNTING SCREW LOCATION
Using 2 no. 8 x 3/8’’ screws from parts bag, assemble the adapter on the top of the power
pack. Seal all joints with metal foil duct tape to eliminate air leaks.
HJ0035
DAMPER HINGE
PARALLEL TO
POWER PACK
SIDES
Install 10” damper inside the VERTICAL ductwork that will be attached to power pack.
Do not install in a horizontal ductwork or it will not open and close properly. Remove
shipping tape if present. To optimize airflow and quiet sound, position the damper at least
17” above the top of the double blower power pack; or as far as the duct run will allow. Also,
ensure the damper hinge will be parallel to power pack sides (see figure at right). Secure
the damper to the duct with 3 no. 8 sheet metal screws (not provided). Check to make sure
damper opens and closes freely. Seal all joints with metal foil duct tape to eliminate air
leaks.
17” min.
HJ0036A
13. REMOVE THE BLOWER
(SINGLE BLOWER MODEL, HORIZONTAL DISCHARGE ONLY)
In order to ease the power pack alignment with horizontal ductwork, disassemble the blower from the power pack before
installing it in the custom hood.
LEFT SIDE MOUNTING
SCREW LOCATION
RIGHT SIDE MOUNTING
SCREW LOCATION
Using a 5/16” socket, or a Phillips no. 2 or a
Robertson no. 2 screwdriver, remove all blower
mounting screws from the inner top of the power
pack. Set blower and screws aside.
HD0368
HD0369
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
14. INSTALL THE POWER PACK
CAUTION
Take care not to kink ducting or pinch electrical cable when installing the power pack.
CLASPING
SPRINGS
Lift the power pack in custom hood until the bottom of the clasping springs
(2 per side) rests on the top of the custom hood base (grey zone in illustration at right).
HD0370
From inside the power pack, using provided no. 8-10 x 1/2” screws, mount the power pack
to the custom hood base. To do so, raise the front until its flange rests on the outer side of
the custom hood base and use 2 screws to secure in place. Do the same for the back, then
complete the installation with 2 additional screws on the front and back. See figure at right
for mounting screws specific locations.
VERTICAL EXHAUST INSTALLATION ONLY
Make sure the adapter/damper enters the ducting and the damper opens freely. Wherever
it is possible, seal connections with metal foil duct tape.
HH0126
15. INSTALL THE ADAPTER/DAMPER ON BACK OF POWER PACK
(SINGLE BLOWER MODEL, HORIZONTAL DISCHARGE ONLY)
From the outside of the wall, using two
no. 8 x 3/8’’ screws provided in parts
bag, secure the adapter/damper to the
back of the power pack. Remove tape
from damper flap. Connect ducting to
the adapter/damper and seal the joint
using metal foil duct tape.
WALL
HH0127A
BACK VIEW
SIDE VIEW
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
16. REINSTALL THE BLOWER (SINGLE BLOWER MODEL, HORIZONTAL DISCHARGE ONLY)
The single blower power pack is factory shipped for a
vertical discharge installation. For a horizontal
discharge installation, the blower must be flipped.
Using a 5/16” socket, or a Phillips no. 2 or a
Robertson no. 2 screwdriver, secure the blower to the
inner back of the power pack with all blower mounting
screws (previously removed in step 13).
RIGHT SIDE
MOUNTING SCREW
LOCATION
LEFT SIDE MOUNTING
SCREW LOCATION
HD0371
HD0372
17. REINSTALL FRONT PANEL AND WIRING COVER
CAUTION
Take care not to pinch wiring when reinstalling the front panel and the wiring cover.
Carefully reassemble the front panel to the power pack by aligning the tabs with their corresponding slot. Using a Robertson
no. 2 or a Phillips no. 2 screwdriver, secure the front panel to the power pack using its both retaining screws (A) previously
removed in step 8. Reassemble the wiring cover using its both retaining screws (B) previously removed in step 8. Plug the
motor(s) (one or two, depending on models) to the front panel.
B
A
HD0365
HE01105
HO0138
18. CONNECT WIRING (ALL MODELS)
!
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally.
Position the power pack below the installed custom hood. Insert the house wiring cable through the wire clamp previously
installed in step 9. Tighten the wire clamp to secure the cable.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
18. CONNECT WIRING (ALL MODELS) (CONT’D)
A
Connect cable using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN
or BARE wire under ground screw (A). DO NOT FORGET TO CONNECT
THE GROUND.
HE0059
19. REINSTALL FILTERS
CAUTION
Remove protective plastic film covering filters before installing them.
1. Using a Phillips no. 2 screwdriver, assemble the knob to each filter.
NOTE: The screw MUST BE on filter tabs side. See illustration at right.
HO0139
2. Rest rear filters edge on filter springs (B) in the power pack.
3. Using knob, tilt up the filters into position. Make sure filter tabs (C) are securely
B
engaged in power pack front edge after installation.
HD0373
C
20. LIGHT BULBS
This power pack requires shielded halogen lamps (120 V, 50 W max., MR16 or PAR16 with GU10 base), included.
!
WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of
personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroïc lamp, a
lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
1. Install the lamps by placing the bulb leads into their grooves in the socket.
1
2
2. Gently push upwards and turn clockwise until secure.
To remove lamps, gently push upwards and turn counterclockwise to disengage
bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the
bulb.
HO0090
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
21. USE AND CARE
Filters
The filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates more
grease — like frying foods or wok cooking.
Remove filters by pushing it towards the back of power pack and rotating filter downward. Filters are dishwasher safe. Allow
filters to dry completely before reinstalling them in the power pack.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filters may occur if using
phosphate detergent or as a result of local water conditions — but this will not affect filter performance. This discoloration is not
covered by the warranty.
Blower(s) Cleaning
Remove the filters in order to access the blower(s). Vacuum blower(s) to clean. Do not immerse in water.
Power Pack Cleaning
Stainless steel cleaning:
Do:
Don’t:
• Use any steel or stainless steel wool or any other scrapers
to remove stubborn dirt.
• Regularly wash with clean cloth or rag soaked with warm
water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after
cleaning. Wipe dry completely.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the
power pack During construction/renovation, cover the power
pack to make sure no dust sticks to stainless steel surface.
• You may also use a specialized household stainless steel
cleaner.
Avoid when choosing a detergent:
-
-
-
Any cleaners that contain bleach will attack stainless steel.
Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
22. OPERATION
Always turn your power pack on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HC0023
A
B
C
D
A. DELAY SWITCH:
When a blower speed is selected, press this switch to activate the delay function. The corresponding blower speed switch
will flash to indicate this function is activated. The blower will continue to operate for 5 minutes and will stop automatically.
To cancel the delay function, press the delay switch once again.
B. START/STOP/SPEED SELECTION SWITCHES:
Press the switch corresponding to the desired blower speed (from 1 for low speed to 4 for high speed). The chosen switch
will light. To turn off the blower, press once more on the corresponding blower speed switch; the switch light will shut off.
NOTE: When blower is off, pressing on blower speed 1 switch will cause the blower to start on high speed for a very
short lapse of time, and then resume on speed 1.
C. MASTER OFF/FILTER MAINTENANCE/HEAT SENTRY (TRIPLE FUNCTION SWITCH):
i. To turn off the blower(s) and the light simultaneously, press this switch once.
ii. After 25 hours of operation, this switch will light to indicate the filters and the blower wheel(s) need to be cleaned in
order to maintain efficient operation of the unit. The switch light will stay on until the function is reset by pressing this
switch for 3 seconds.
iii. The light indicator is used for the Heat Sentry function as well.
HEAT SENTRY: The hood is equipped with a protective device that activates when excessive heat is detected inside the hood
and when it is set on speed 4.This device takes control of the blower and deactivates speed 4 for a 10-minute
period and sets it on speed 3. During the Heat Sentry activation, only speed 3 can be used; the Heat Sentry
button (C) will flash while the speed 3 button will light. The hood can also be turned OFF.
D. LIGHT SWITCH:
This switch allows three different lighting levels according to your needs. Press once for nightlight, twice for normal or three
times to obtain full intensity. To shut off the lights without turning off the blower, press once more.
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
23. WIRING DIAGRAM
BLK
LINE
WHT
NEUTRAL
GROUND
Q1
TRANSFORMER
LOGIC
BLK
WHT
RED 9.5 V
BLK
K1
K2
YEL
COLOR CODE
BLK
BLU
BLACK
BLUE
YEL
A1
ELECTRONIC
ASSEMBLY
BRN
GRY
ORG
RED
WHT
YEL
BROWN
GREY
ORANGE
RED
WHITE
YELLOW
YEL
J1
120 V LINE
K3
K4
WHT
REF
1
WHT
YEL
10 VAC
2
3
K1 NC
K2 NO
K2 NC
K3 NC
K4 NO
WHT
BLOWER MOTOR
K1 NO
K3 NO
J2
GRY
BLU
BLU
BLU
WHT
ORG
BLK
WHT
WHT
ORG
1
ORG
BRN
M
2
3
BLK
BLK
RED
WHT
4
5
BLU
WHT
WHT
OPTIONAL SECOND
BLOWER MOTOR
M
ORG
BLK
BLK
HE0132A
24. WARRANTY
ONE YEAR LIMITED WARRANTY FOR BROAN ELITE PRODUCTS
Broan-NuTone Canada (Broan-NuTone) warrants to the original consumer purchaser of Broan Elite products that such products will be free
from defects in materials or workmanship for a period of one year from the date of original purchase.THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSE,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or
repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
Warranty service is to be completed by an authorized Service Center designated by Broan-NuTone. Where applicable, in-home service will
be made available only in areas where a contracted service provider offers service. If in-home service is not available, the product will be
repaired or replaced, at Broan-NuTone’s discretion, by the nearest authorized service provider. The unit removal and reinstallation works are
under the customer responsibility, and Broan-NuTone cannot be charged for them.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some provinces do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE
AND EXCLUSIVE REMEDY UNDERTHIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some provinces do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from province to another. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you
must present evidence of the original purchase date.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
25.SERVICE PARTS
EC621306SS
EC622301SS
1
1
11
11
10
10
2
2
3
3
4
5
4
9
5
6
9
8
8
6
7
7
HL0169
QTY. (POWER PACK MODEL)
EC621306SS EC622301SS
KEY
PART NO.
NO.
DESCRIPTION
SV13296 ADAPTER/DAMPER 3¼” X 10”
SV08541 ADAPTER 10” ROUND
1
-
-
1
1
2
3
SV09226 ELECTRONIC CONTROL WITH CHROMED BUTTONS AND BLUE LEDS
SV05917 SOCKET
1
2
1
2
4
SV05921 SOCKET HOLDER
2
2
5
SV09435 LIGHT TRIM
2
2
6
7
SV09434 SHIELDED HALOGEN BULB (120 V, 50 W, GU-10)
SV18428 THIN BAFFLE FILTER
2
2
2
2
8
9
10
11
*
SV08967 FILTER KNOBS (INCLUDING SCREWS) (QTY. 2)
SV08582 INTERNAL BLOWER
SV09022 TRANSFORMER
SV06750 BROAN ELITE LOGO
SV08970 INSTALLATION GUIDE
1 PAIR
1 PAIR
1
1
1
1
2
1
1
1
PARTS BAG: 2 WIRE CONNECTORS, 1 WIRE CLAMP,
SV08545 4 SCREWS NO. 8 X 3/8”, 9 CHROMED PLATED SCREWS NO. 8-10 X 1/2”,
10 MECHANICAL SCREWS NO. 8-32 X 1/4”
*
1
1
*NOT SHOWN.
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only. Broan-NuTone
genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and
maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance
level of your unit, which will result in premature failing. Broan-NuTone recommends to contact a certified service depot for all replacement
parts and repairs.
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|