Bosch Appliances Security Camera LTC 9385 User Manual

LTC 9385 Series  
Instruction Manual  
EN Outdoor Housings  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Safety Precautions  
EN 3  
Safety Precautions  
For Indoor Product  
1. Water and Moisture - Do not use this unit near  
water - for example, in a wet basement, in an  
unprotected outdoor installation or in any area  
classified as a wet location.  
CAUTION: TO REDUCE THE RISK OF  
2. Object and Liquid Entry - Never push objects of  
any kind into this unit through openings, as they  
may touch dangerous voltage points or short out  
parts that could result in a fire or electrical shock.  
Never spill liquid of any kind on the unit.  
3. Power Cord and Power Cord Protection - For  
units intended to operate with 230VAC, 50Hz,  
the input and output power cord must comply  
with the latest versions of IEC Publication 227 or  
IEC Publication 245.  
ELECTRIC SHOCK, DO NOT REMOVE COVER  
(OR BACK). NO USER SERVICEABLE PARTS  
INSIDE. REFER SERVICING TO QUALIFIED  
SERVICE PERSONNEL.  
This symbol indicates the presence of  
uninsulated “dangerous voltage” within the  
product’s enclosure. This may constitute a  
risk of electric shock.  
The user should consult the operating and  
maintenance (servicing) instructions in the  
literature accompanying the appliance.  
Power supply cords should be routed so they are  
not likely to be walked on or pinched. Pay  
particular attention to location of cords and plugs,  
convenience receptacles, and the point of exit  
from the appliance.  
Attention: Installation should be performed by  
qualified service personnel only in accordance  
with the National Electrical Code or applicable  
local codes.  
4. Overloading - Do not overload outlets and  
extension cords; this can result in a risk of fire or  
electrical shock.  
Power Disconnect. Units with or without  
ON-OFF switches have power supplied to the  
unit whenever the power cord is inserted into the  
power source; however, the unit is operational  
only when the ON-OFF switch is in the ON  
position. The power cord is the main power  
disconnect for all units.  
For Outdoor Product  
Power Lines - An outdoor system should not be  
located in the vicinity of overhead power lines,  
electric lights or power circuits, or where it may  
contact such power lines or circuits. When  
installing an outdoor system, extreme care should  
be taken to keep from touching power lines or  
circuits, as this contact might be fatal. U.S.A.  
models only - refer to the National Electrical  
Code Article 820 regarding installation of CATV  
systems.  
For Rack-mount Product  
1. Ventilation - This unit should not be placed in a  
built-in installation or rack, unless proper  
ventilation is provided, or the manufacturer’s  
instructions have been adhered to. The  
equipment must not exceed its maximum  
operating temperature requirements.  
2. Mechanical Loading - Mounting of the  
equipment in a rack shall be such that a  
hazardous condition is not achieved due to  
uneven mechanical loading.  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Safety Precautions  
EN 4  
Sécurité  
Sicherheitshinweise  
ATTENTION : POUR ÉVITER TOUT RISQUE D'ÉLECTROCUTION,  
N'ESSAYEZ PAS DE RETIRER LE CAPOT (OU LE PANNEAU  
ARRIÈRE). CET APPAREIL NE CONTIENT AUCUN COMPOSANT  
SUSCEPTIBLE D'ÊTRE RÉPARÉ PAR L'UTILISATEUR. CONFIEZ  
LA RÉPARATION DE L'APPAREIL À DU PERSONNEL QUALIFIÉ.  
VORSICHT: UM EINEN ELEKTRISCHEN SCHLAG ZU  
VERMEIDEN, IST DIE ABDECKUNG (ODER RÜCKSEITE) NICHT  
ZU ENTFERNEN. ES BEFINDEN SICH KEINE TEILE IN DIESEM  
BEREICH, DIE VOM BENUTZER GEWARTET WERDEN  
KÖNNEN. LASSEN SIE WARTUNGSARBEITEN NUR VON  
QUALIFIZIERTEM WARTUNGSPERSONAL AUSFÜHREN.  
Ce symbole signale que le produit renferme une « tension  
potentiellement dangereuse » non isolée susceptible de  
provoquer une électrocution.  
Das Symbol macht auf nicht isolierte „gefährliche Spannung"  
im Gehäuse aufmerksam. Dies kann zu einem elektrischen  
Schlag führen.  
Ce symbole invite l'utilisateur à consulter les instructions  
d'utilisation et d'entretien (dépannage) reprises dans la  
documentation qui accompagne l'appareil.  
Der Benutzer sollte sich ausführlich über Anweisungen für  
die Bedienung und Instandhaltung (Wartung) in den  
begleitenden Unterlagen informieren.  
Attention : l'installation doit exclusivement être réalisée par du  
personnel qualifié, conformément au code national d'électricité  
américain (NEC) ou au code d'électricité local en vigueur.  
Achtung! Die Installation sollte nur von qualifiziertem  
Kundendienstpersonal gemäß jeweils zutreffender  
Elektrovorschriften ausgeführt werden.  
Coupure de l'alimentation. Qu'ils soient pourvus ou non d'un  
commutateur ON/OFF, tous les appareils reçoivent de l'énergie une  
fois le cordon branché sur la source d'alimentation. Toutefois,  
l'appareil ne fonctionne réellement que lorsque  
le commutateur est réglé sur ON. Le débranchement du cordon  
d'alimentation permet de couper l'alimentation des appareils.  
Unterbrechung des Netzanschlusses. Geräte mit oder ohne  
Netzschalter haben Spannung am Gerät anliegen, sobald der  
Netzstecker in die Steckdose gesteckt wird. Das Gerät ist jedoch  
nur betriebsbereit, wenn der Netzschalter (EIN/AUS) auf EIN  
steht. Wenn das Netzkabel aus der Steckdose gezogen wird, ist  
die Spannungszuführung zum Gerät vollkommen unterbrochen.  
Precauciones de Seguridad  
Veiligheidsmaatregelen  
PRECAUCIÓN: PARA DISMINUIR EL RIESGO DE DESCARGA  
ELÉCTRICA, NO RETIRE LA CUBIERTA (NI LA PARTE  
POSTERIOR). NO EXISTEN PIEZAS DE RECAMBIO EN EL  
INTERIOR DEL EQUIPO. EL PERSONAL DE SERVICIO  
CUALIFICADO SE ENCARGA DE REALIZAR LAS  
REPARACIONES.  
VOORZICHTIG: OPEN DE BEHUIZING OF DE ACHTERKANT  
VAN HET APPARAAT NIET. ZO VERMINDERT U HET RISICO  
OP ELEKTRISCHE SCHOKKEN. IN HET APPARAAT  
BEVINDEN ZICH GEEN ONDERDELEN DIE U ZELF KUNT  
REPAREREN. LAAT SERVICE EN ONDERHOUD UITVOEREN  
DOOR GEKWALIFICEERD PERSONEEL.  
Este símbolo indica que existen puntos de tensión peligrosos  
sin aislamiento dentro de la cubierta de la unidad. Estos  
puntos pueden constituir un riesgo de descarga eléctrica.  
Dit symbool geeft aan dat er binnen in het apparaat  
ongeïsoleerde, gevaarlijke spanning aanwezig is die mogelijk  
elektrische schokken kan veroorzaken.  
El usuario debe consultar las instrucciones de funcionamiento y  
mantenimiento (reparación) en la documentación que se  
suministra con el aparato.  
De gebruiker dient de bedienings- en onderhoudsvoorschriften  
te raadplegen in de documentatie die werd meegeleverd met  
het apparaat.  
Atención: la instalación la debe realizar únicamente personal  
cualificado de conformidad con el National Electric Code o las  
normas aplicables en su país.  
Attentie: het apparaat mag alleen door gekwalificeerd personeel  
worden geïnstalleerd. De installatie dient in overeenstemming  
met de nationale elektrische richtlijnen of de van toepassing  
zijnde lokale richtlijnen te worden uitgevoerd.  
Desconexión de la alimentación. Las unidades con o sin  
interruptores de encendido/apagado reciben alimentación  
eléctrica siempre que el cable de alimentación esté conectado a  
la fuente de alimentación. Sin embargo, la unidad sólo funciona  
cuando el interruptor está en la posición de encendido. El cable  
de alimentación es la principal fuente de desconexión de todas  
las unidades.  
Spanning uitschakelen. Apparatuur met of zonder  
aan-uitschakelaar staat onder spanning zolang de stekker is  
aangesloten op de wandcontactdoos. De apparatuur is uitsluitend  
in werking als de aan-uitschakelaar aan staat. Het netsnoer is de  
"hoofdschakelaar" voor alle apparatuur.  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Safety Precautions  
EN 5  
Medidas de Segurança  
Sicurezza  
CUIDADO: PARA REDUZIR O RISCO DE CHOQUE  
ELÉCTRICO, NÃO RETIRE A TAMPA (OU A PARTE  
POSTERIOR). NO INTERIOR, NÃO EXISTEM PEÇAS QUE  
POSSAM SER REPARADAS PELO UTILIZADOR. REMETA A  
ASSISTÊNCIA PARA OS TÉCNICOS QUALIFICADOS.  
ATTENZIONE: PER RIDURRE IL RISCHIO DI SCOSSE  
ELETTRICHE NON RIMUOVERE LA COPERTURA (O IL  
PANNELLO POSTERIORE). L'UNITÀ NON CONTIENE  
COMPONENTI INTERNI RIPARABILI DALL'UTENTE. PER  
QUALSIASI INTERVENTO, RIVOLGERSI A PERSONALE  
TECNICO QUALIFICATO.  
Este símbolo indica a presença de "tensão perigosa" não isolada  
dentro da estrutura do produto, o que pode constituir risco de  
choque eléctrico.  
Questo simbolo indica la presenza di "tensione pericolosa" non  
isolata all'interno del contenitore del prodotto. Ciò comporta un  
potenziale rischio di scosse elettriche.  
O utilizador deve consultar as instruções de funcionamento  
e manutenção (assistência) nos documentos que  
acompanham o aparelho.  
Si consiglia di consultare le istruzioni operative e di  
manutenzione (interventi tecnici) contenute nella  
documentazione fornita con il dispositivo.  
Atenção: a instalação deve ser executada apenas por técnicos  
qualificados da assistência, de acordo com o código eléctrico  
nacional ou os códigos locais aplicáveis.  
Attenzione: l'installazione deve essere effettuata esclusivamente  
da personale tecnico qualificato in conformità con il National  
Electrical Code o con le normative locali vigenti.  
Corte de corrente. As unidades com ou sem interruptores  
ON-OFF (ligar/desligar) recebem corrente sempre que o fio de  
alimentação está introduzido na fonte de alimentação; contudo, a  
unidade apenas está operacional quando o interruptor ON-OFF  
está na posição ON. O fio de alimentação destina-se a desligar a  
corrente em todas as unidades.  
Scollegamento dell'alimentazione. Le unità dotate o sprovviste di  
interruttori ON-OFF vengono alimentate quando si inserisce il  
cavo nella presa dell'alimentazione. L'unità è tuttavia in funzione  
solo quando l'interruttore ON-OFF si trova nella posizione ON. Il  
cavo di alimentazione costituisce il dispositivo di scollegamento  
dell'alimentazione principale per tutte le unità.  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Contents  
EN 6  
Table of Contents  
Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
1.0  
2.0  
3.0  
4.0  
4.1  
5.0  
5.1  
5.2  
5.3  
5.4  
5.5  
5.6  
5.7  
5.8  
5.9  
UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Enclosure Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Model Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Hardware Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Disassembly and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Camera/Lens Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
Camera/Lens Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
Plug Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
Video Coax Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
5.10 Lens Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
5.11 Camera/Lens Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
5.12  
Camera/Lens Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
5.13 Final Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
6.0  
7.0  
EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Unpacking  
EN 7  
1.0 UNPACKING  
3.0 CARE AND MAINTENANCE  
This electronic equipment should be unpacked and  
handled carefully.  
There are no moving parts in this unit. Regularly  
scheduled maintenance will help prolong the  
operational life of this unit. Clean the viewing window  
as needed with a mild, nonabrasive detergent in water  
and a soft cloth.  
Check for the following items:  
Quantity  
1
Part Description  
1/4-20 x 3/8in. BHCS (Button Head Cap  
Screw)  
4.0 DESCRIPTION  
1
1
1
1
4
4
2
1
1
2
2
3
1/4-20 x 1/2in. BHCS  
1/4-20 x 5/8in. BHCS  
1/4-20 x 3/4in. BHCS  
1/4-20 x 7/8in. BHCS  
3.2mm (0.125in.) plastic spacer  
0.4mm (0.016in.) plastic spacer  
Nylon bushings  
3/8in. NPT plug  
Small flex fitting  
Pull Seals  
Large flex fitting  
The LTC 9385 Series of environmental housings are  
attractive aluminum enclosures designed for outdoor  
CCD camera installations.  
4.1  
4.1.1  
Enclosure Rating  
NEMA-3R and IP54  
The LTC 9385 Series housings include a breather hole in  
the front face plate. The breather hole prevents the  
accumulation of moisture inside the housing when  
installed in areas of high humidity. With the breather  
hole open, the LTC 9385 Series housings meet the  
enclosure rating requirements of NEMA-3R and IP54.  
Cable ties  
If an item appears to have been damaged in shipment,  
replace it properly in its carton and notify the shipper.  
If any items are missing, notify your Bosch Security  
Systems Inc. Sales Representative or Customer Service.  
4.1.2 NEMA-4 and IP65  
For installations requiring an enclosure rating of  
NEMA-4 or IP65, the breather hole must be plugged  
using the pull seal (Part No. 315 2569 001) provided in  
the hardware kit. Refer to Final Assembly under  
INSTALLATION for proper installation.  
The shipping carton is the safest container in which the  
unit may be transported. Save it for possible future use.  
5.0 INSTALLATION  
2.0 SERVICE  
This installation should be made by a qualified  
service person and conform to all local codes.  
If the unit ever needs repair service, the customer  
should contact the nearest Bosch Security Systems, Inc.  
Service Center for return authorization and shipping  
instructions.  
5.1  
Model  
No.  
Model Designation  
Rated  
Range  
Power  
Consumption1  
Input  
Service Centers  
USA  
LTC 9385/60 115VAC, 50/60Hz 108 to 132 50W  
LTC 9385/20 24VAC, 50/60Hz 21.6 to 26.4 50W  
Phone:  
fax:  
800-366-2283 or 717-735-6638  
800-366-1329 or 717-735-6639  
LTC 9385/50 230VAC, 50/60Hz 207 to 253 50W  
1Heater requires 40 watts.  
CCTV Spare Parts  
Phone:  
fax:  
e-mail:  
800-894-5215 or 408-956-3853 or 3854  
408-957-3198  
Do Not Exceed 30VAC Input on 24VAC models.  
Operation above 30VAC violates low voltage operation  
(Class 2 Specifications). Normal operation is 24VAC.  
Canada  
Phone:  
514-738-2434  
Maximum Camera/Lens Size: Accepts cameras  
up to 102W x 71H mm (4.0 x 2.8in.), lenses up to  
102W x 92H mm (4.0 x 3.6in.), and camera/lens  
combinations up to 345L mm (13.6in.).  
Europe, Middle East & Asia Pacific Region  
Phone: 32-1-440-0711  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 8  
Input Power Cord - European  
5.2 Tools Required  
Cable Type  
Cable Size  
H05RN-F3G0.75 and  
H05RN-F3G1.00  
Flat blade screwdriver  
Phillips head screwdriver  
M7 (7mm) hex wrench or socket  
M3 (3mm) hex wrench  
M4 (4mm or 5/32in.) hex wrench  
M8 (8mm or 5/16in.) hex wrench  
Adjustable wrench  
Outside diameter between 4.3mm  
and 11.9mm (0.170in. and 0.470in.)  
Cable Shape  
Conductors  
Round  
3 conductor version and  
2 conductor version  
Agency Rating  
Environmental  
Sources  
VDE  
Wire cutter/stripper/crimper tool  
Outdoor rated  
Olflex 1600252  
Olflex 1600253  
5.3 Hardware Required  
M6 screws (X3) or 1/4in. screws (X3)  
M6 nuts (X3) or 1/4in. nuts (X3)  
M6 lock washers (X3) or  
Lens Control Cable  
Cable Type  
Cable Size  
Jacketed Multiconductor Cable  
1/4in. lock washers (X3)  
Outside diameter between 4.3mm  
and 11.9mm (0.170in. and 0.470in.)  
Cable Shape  
Shield  
Round  
5.4 Cable Requirements  
Overall shielding  
Video Transmission (Coaxial)  
Conductors  
Stranded 20 to 16 AWG wire  
4 and 8  
Cable Type  
Cable Size  
RG-59/U (Runs < 1000ft)  
RG-11/U (Runs < 2000ft)  
No. of Conductors  
Conductor Insulation  
Color coded  
Outside diameter between 4.6mm  
and 7.9mm (0.181in. and 0.312in.)  
Sources  
Belden 9552  
Belden 9554  
Cable Shape  
Shield  
Round  
93% Braided Copper Shield  
Stranded Copper Center  
Center Conductor  
5.5 Disassembly and Mounting  
DC Resistance  
15/1000ft (RG-59/U)  
6/1000ft (RG-11/U)  
1. Detach the hardware kit from the housing.  
Cable Impedence  
75Ω  
2. Use a M7 hex wrench or socket to remove the  
two M4 screws from the housing cover. Save all  
hardware, which will be needed in reassembly.  
See FIGURE 1.  
Agency Rating  
Environmental  
Temperature Rating  
Sources  
UL  
Outdoor rated  
80 °C (176 °F)  
Belden 9259  
Belden 9238  
Input Power Cord - North American  
Cable Type  
SJTOW-A Rated  
Cable Size  
Outside diameter between 4.3mm  
and 11.9mm (0.170in. and 0.470in.)  
Cable Shape  
Conductors  
Round  
3 conductor version and  
2 conductor version  
Agency Rating  
Environmental  
UL/C.S.A., UL VW-1  
Outdoor rated  
105 °C  
Temperature Rating  
M4 Screws  
Voltage Rating  
Sources  
300 V  
FIGURE 1 Removing the M4 Cover Screws  
Belden 19506  
Belden 19509  
Northwire 573939  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 9  
3. Remove the cover from the base assembly by  
grasping the cover and gently pulling forward.  
Do not remove the safety cable from the cover  
or the base assembly. See FIGURE 2.  
5.6  
Camera/Lens Installation  
Place the camera/lens combination onto the rail  
assembly.  
Fixed Lens Cameras: Position the camera/lens so that  
the lens is positioned over the heater but not past it.  
Secure the camera to the rail assembly with the  
1/4-20 x 3/8in. BHC screw, a nylon bushing, and a  
0.4mm (0.016in.) plastic spacer. Place the nylon  
bushing over the screw and slide both between the  
rails through the front cut-out section. Slide the spacer  
over the screw so it is positioned in-between the rails  
and the camera. See FIGURE 4.  
Cover  
Base Assembly  
FIGURE 2 Removing the Cover  
4. Attach the housing to an appropriate mount or  
pan/tilt. Use the instructions provided with the  
mount or pan/tilt. The base assembly has three  
clearance holes for mounting. Use three M6  
screws and nuts or three 1/4in. screws and nuts  
(not provided). Lock washers are required (not  
provided). Rotating the rail assembly will allow  
access to the mounting holes. This can be  
accomplished by loosening the three M4 screws.  
See also Camera/Lens Orientation. It will be easier  
to mount the base before installing the camera,  
but it may be mounted anytime during the  
installation process. See FIGURE 3.  
FIGURE 4 Mounting a Fixed Lens Camera  
Zoom Lens Cameras: Position the camera/lens so  
that the lens is positioned over the heater but not past  
it. The camera/lens combination will determine the  
screws and spacers that will be needed. Secure the  
camera and lens to the rail assembly with 1/4-20 BHC  
screws, nylon bushings, and plastic spacers. Place the  
nylon bushings over the screws and slide both between  
the rails through the front cut-out section. Slide the  
spacer over the screw so it is positioned in-between the  
rails and the camera. There are four large spacers  
(3.2mm) and four small spacers (0.4mm) provided.  
See FIGURE 5.  
Rail Assembly  
M4 Screws  
Camera  
Mounting Holes  
FIGURE 3 Mounting the Base Assembly  
Spacer  
Spacer  
Bushing  
Rails  
Screw  
FIGURE 5 Mounting a Zoom Lens Camera  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 10  
5.7  
Camera/Lens Wiring  
5.8  
Plug Insertion  
WARNING: Only use the cables specified  
under INSTALLATION, Cable Requirements for  
wiring of all cameras and lenses.  
If no lens control or feed-through wiring will be used,  
install the 3/8in. NPT plug provided. Remove the  
liquid-tight fitting and insert the plug in the small  
bottom center 3/8in. NPT hole. Use a 8mm or a  
5/16in. hex wrench to tighten securely. Failure to do so  
will result in water damage to all electronic parts. See  
FIGURE 7.  
5.7.1 Liquid-Tight Fittings  
The dual-male threaded portion of the two 1/2in. NPT  
and one 3/8in. NPT liquid-tight fittings are preinstalled  
in the rear of the base assembly. If possible, do not  
remove or loosen these parts. They have been installed  
to a specified torque to prevent water damage. The  
small 3/8in. NPT fitting will accept cables with  
diameters from 4.6mm (0.181in.) to 7.9mm (0.31in.).  
The two large 1/2in. NPT fittings will accept cables  
with diameters from 4.3mm (0.170in.) to 11.9mm  
(0.470in.). See FIGURE 6.  
3/8in. NPT Plug  
Be sure to securely tighten all fittings to ensure  
a liquid-tight seal. Not doing so could damage  
the camera, the housing, or both.  
FIGURE 7 3/8in. NPT Plug Insertion  
5.8.1 Supply Power Connections  
The LTC 9385 Series housings offer the user one of three  
voltage configurations. The suffix to the housing model  
number will determine the supply voltage required.  
If a sealant will be used, be sure it is a neutral cure  
type. Sealants that release acetic acid may harm  
camera electronics.  
Any camera installed in the LTC 9385 Series housings  
must be of the same voltage type as the housing. The  
integral heater/defogger also requires the same voltage as  
the housing. These housings do not contain step down or  
isolation transformers. See the Model Designation chart  
for suffixes and supply voltages required.  
If it is necessary to use PG type conduit, a TC9385PG  
kit is available. The TC9385PG kit contains a wire  
grip with two PG11 and one PG7 tapped holes. The  
NPT wire grip is removed and replaced with the PG  
version.  
Power connection into the housings is to be supplied  
through a minimum type UL Standard SJ cord  
acceptable for outdoor use. Installation must conform  
to applicable NEC and local codes. Use the  
Recommended Maximum Cable Lengths chart  
below for proper wire size selection.  
Dual Male  
Portion  
Wire Grip  
Seal Glands  
Flexible Portion  
FIGURE 6 Liquid-tight Fitting Assembly  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 11  
4. Connect both the line and neutral wires of the  
Recommended Maximum Cable Lengths  
Models  
Wire Size  
Distance  
power cord to the terminal block. Make sure  
the line and neutral wires are connected to the  
correct positions on the terminal block that are  
across from the appropriate colored wire. See  
FIGURE 9.  
mm2  
1.5  
2.5  
4
AWG  
16  
meters feet  
-1 (115 VAC)  
1000  
1600  
2500  
3280  
5250  
8200  
14  
12  
-2 (24 VAC)  
0.5  
0.5  
1
1.5  
2.5  
22  
20  
18  
16  
14  
10  
15  
25  
40  
70  
30  
50  
80  
120  
210  
-4 (230 VAC)  
1.5  
2.5  
4
16  
14  
12  
4000  
6400  
10000  
13000  
21000  
32800  
FIGURE 9 Attaching Line and Neutral Wires  
1. Use the liquid-tight fitting on the left of the  
housing to route the power supply cord into the  
housing.  
5. Pull any excess cord through the liquid-tight  
fitting and tighten the flex fitting to 8.5N-m to  
9.0N-m (75in. lb to 80in. lb). This torque rating  
is approximately 1 to 1 1/2 turns past the point  
that the fitting starts to grip the cord. Failure to  
do so will result in water damage to all  
2. Allow enough cord for connection to the  
terminal block; approximately, 130mm (5in.).  
Strip no less than 6mm (0.24in.) and no more  
than 8mm (0.31in.) of insulation away from the  
wires making sure not to nick the wires.  
electronic parts. Use a tie wrap (included) to  
provide strain relief on the power cord at the  
exit point (inside the unit).  
3. A screw/terminal lug is provided for securing a  
safety ground. To attach the safety grounding  
wire of the power cord (green 115volt,  
Securely tighten all fittings to ensure a liquid-  
tight seal. Not doing so could damage the  
camera, the housing, or both.  
green/yellow 230volt), first unscrew the terminal  
lug and strip and crimp the grounding wire into  
the lug. Next, reattach the terminal lug to the  
rail assembly using the M4 x 10 screw and lock  
washer provided. See FIGURE 8.  
5.8.2 Camera Power Connections  
LTC 9385/60 Housings  
These housings are to be connected to 115VAC, and  
are designed for use where site power is 115volts. The  
LTC 9385/60 housings should only be used with  
115volt cameras. The integral heater/defogger  
requires 115volts. The housing is shipped with the  
heater/defogger connected to the terminal block.  
Installing a 115 volt camera into the LTC 9385/60  
housing simply requires the camera's line cord to be  
plugged into the NEMA 5-15R receptacle provided.  
See FIGURE 10.  
FIGURE 8 Securing the Ground Wire  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 12  
LTC 9385/20 Housings  
5.9  
Video Coax Connection  
These housings are to be connected to 24VAC, and  
are designed for use where site power is 24volts. The  
LTC 9385/20 housings should only be used with  
24volt cameras. The integral heater/defogger requires  
24volts. The housing is shipped with the heater/  
defogger connected to the terminal block.  
WARNING: Only use the cables specified  
under INSTALLATION, Cable Requirements for  
wiring of the video coax connection.  
If lens control or feed-through wires will be used:  
1. Install the long flexible portion of the small  
liquid-tight fitting on the video coax cable and  
pull the cable through the small fitting on the  
rear end of the base assembly. The fitting will  
accept cables with diameters from 4.6mm  
(0.181in.) to 7.9mm (0.312in.). See FIGURE 11.  
Installing a 24 volt camera into the LTC 9385/20  
housing simply requires the two flying leads be attached  
to the camera's terminal block. See FIGURE 10.  
LTC 9385/50 Housings  
These housings are to be connected to 230VAC, and  
are designed for use where site power is 230volts. The  
LTC 9385/50 housings should only be used with  
230volt cameras. The integral heater/defogger requires  
230volts. The housing is shipped with the  
2. Attach a BNC connector to the coax and connect  
it to the camera. Pull any excess cable through  
the liquid-tight fitting and tighten the flex fitting  
to 4.0N-m to 4.5N-m (35in. lb to 40in. lb). This  
torque rating is approximately 1 to 1 1/2 turns  
past the point that the fitting starts to grip the  
cable. Failure to do so will result in water  
heater/defogger connected to the terminal block.  
Installing a 230 volt camera into the LTC 9385/50  
housing simply requires the camera's line cord to be  
plugged into the Schuko inline receptacle provided.  
See FIGURE 10.  
damage to all electronic parts. Use a tie wrap  
(included) to provide strain relief on the video  
cable at the exit point (inside the unit).  
Be sure to securely tighten all fittings to ensure  
a liquid-tight seal. Not doing so could damage  
the camera, the housing, or both.  
If no lens control or feed-through wires will be used:  
1. Install the long flexible portion of a large  
liquid-tight fitting on the video coax cable and  
pull the cable through the large right fitting on  
the rear end of the base assembly. Refer to  
FIGURES 11 and 12.  
2. Attach a BNC connector to the coax and  
connect it to the camera. Pull any excess cable  
through the liquid tight fitting and tighten the  
flex fitting to 8.5N-m to 9.0N-m (75in. lb to  
80in. lb). This torque rating is approximately  
1 to 1 1/2 turns past the point that the fitting  
starts to grip the wire. Failure to do so will  
result in water damage to all electronic parts.  
Use a tie wrap (included) to provide strain relief  
on the video cable at the exit point (inside the  
unit).  
FIGURE 10 Camera Connections  
Be sure to securely tighten all fittings to  
ensure a liquid-tight seal. Not doing so could  
damage the camera, the housing, or both.  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 13  
If using a pan/tilt with a feed-through cable, insert  
the camera/lens function cable in through the right  
fitting at the rear of the cradle. Wire the functions as  
described above, or as needed.  
BNC Connector  
Video Coax Cable  
CCD Camera  
5.11 Camera/Lens Orientation  
A unique feature of the LTC 9385 Series housing is  
the ability to rotate the mounting base 360º around  
the rail assembly.  
Small Fitting  
Video Coax Cable  
CCD Camera  
BNC Connector  
Simply loosen the three M4 screws with a M3 hex  
wrench. Rotate the base assembly around the rail  
assembly to any position and tighten the M4 screws.  
It is preferable to keep the rail assembly under the  
camera, not over it. See FIGURE 13.  
Small Fitting  
FIGURE 11 Video Coax Connection  
5.10 Lens Wiring  
WARNING: Only use the cables specified  
under INSTALLATION, Cable Requirements for  
wiring of the lens.  
NOTE: Make sure the breather hole is located at the  
bottom of the housing. If it is not, remove both front  
retaining rings and the face plate. Orient them so the  
breather hole is located at the bottom and the gaps in  
the retaining rings are centered over the breather hole.  
See FIGURE 20.  
If installing a zoom lens, insert the lens control cable  
with installed flexible fitting in through the fitting on  
the right rear of the base assembly. Attach the lens  
wiring to the lens mating connector and connect it to  
the lens. If mating connector is not available, connect  
directly to the lens cable. Pull any excess cable  
through the liquid-tight fitting and tighten the flex  
fitting to 8.5N-m to 9.0N-m (75in. lb to 80in. lb). This  
torque rating is approximately 1 to 1 1/2 turns past  
finger-tight, depending on the size of the wire. Failure  
to do so will result in water damage to all electronic  
parts. Use a tie wrap (included) to provide strain relief  
on the lens control cable at the exit point (inside the  
unit). See FIGURE 12.  
Base Assembly  
M4 Screws  
NOTE: See specification on the lens cord for correct  
plug connection.  
FIGURE 13 Base Assembly Rotation  
Be sure to securely tighten all fittings to ensure  
a liquid-tight seal. Not doing so could damage  
the camera, the housing, or both.  
5.12 Camera/Lens Adjustment  
Before final assembly of the cover over the rest of  
housing, verify camera and lens operation. Adjust  
camera/lens as necessary. See individual camera  
instructions.  
CCD Camera  
Lens Control Connectors  
Lens Control Cable  
CCD Camera  
FIGURE 12 Lens Control Cable Wiring  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 14  
3. Insert the long end of the pull seal into the  
5.13 Final Assembly  
breather hole starting from the front side of the  
face plate. See FIGURE 16.  
5.13.1 Pull Seal Installation  
If the breather hole is open, do NOT mount the  
housing in a position where the front face  
plate is pointed upward.  
Housing  
Face Plate  
To maintain enclosure protection ratings of NEMA-4  
and IP65, the pull seal (provided in the hardware kit)  
must be installed in the front face plate. It is  
recommended that the pull seal be installed in a cool,  
dry environment to prevent trapping moisture inside  
the housing. See FIGURE 14.  
Pull Seal  
NOTE: Pull seal installation allows the housing’s front  
end to be pointed upward.  
FIGURE 16 Inserting the Pull Seal  
4. Reach into the housing and grip the pull seal’s  
long end from the back of the front face plate.  
Steadily pull the long end until the head of the  
pull seal is flat against the front of the end cap.  
See FIGURE 17.  
Front  
Face  
Plate  
NOTE: The Pull Seal’s long end will stretch when  
pulled through the breather hole.  
Breather Hole  
Housing (cut away)  
FIGURE 14 Breather Hole  
Proper installation of the pull seal is as follows:  
1. If the housing assembly is not already removed  
from the base assembly, do so now; see the  
Disassembly and Mounting section at the beginning  
of these instructions.  
Grip and Pull  
2. Obtain a rubber pull seal from the hardware kit  
(Part Number 315 2569 001). An extra pull seal  
is also provided. See FIGURE 15.  
FIGURE 17 Installing the Pull Seal  
FIGURE 15 Pull Seal  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Installation  
EN 15  
3. Align the cover holes with the base assembly  
5.13.2 Housing Assembly  
holes and replace the two M4 screws and  
washers. This secures the cover onto the rest of  
the housing.  
1. The lens support screw is provided to support  
the rail assembly. Adjustment will only be  
necessary if the rail assembly is rotated at angle  
other than horizontal. If the screw head is not  
touching the cover when the cover is installed,  
loosen the screw until it does. See FIGURE 18.  
NOTE: Make sure the breather hole is located at the  
bottom of the housing. If it is not, remove both front  
retaining rings and the face plate. Orient them so the  
breather hole is located at the bottom and the gaps in  
the retaining rings are centered over the breather hole.  
See FIGURE 20.  
Front  
Face  
Plate  
Lens Support Screw  
FIGURE 18 Support Screw Adjustment  
Retaining Ring  
2. Replace the cover onto the base assembly by  
grasping the cover and gently pushing it over the  
end cap and o-ring. Make sure the o-ring is not  
pinched. The safety cable can be routed between  
the cover and the base. See FIGURE 19.  
Breather Hole (centered)  
FIGURE 20 Location of the Breather Hole  
Cover  
Base Assembly  
End Cap  
FIGURE 19 Replacing the Cover  
Bosch Security Systems | January 26, 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 9385 Series | Instruction Manual | Exploded View  
EN 16  
6.0 EXPLODED VIEW  
FIGURE 21  
7.0 PARTS LIST  
Ref  
No.  
Drawing  
No.  
Ref  
No.  
Drawing  
No.  
Qty.  
Part Description  
Qty.  
Part Description  
Mounting Base Assembly Kit - 315 2805 001  
115VAC Heater-Bracket Assembly Kit - 315 2809 001  
1
2
-
1
1
1
2
7
3
3
Mounting Base Assembly  
Wire Grip Cap  
EP O-ring 037  
EP O-ring 248  
M4 Internal Star Lock Washer  
M4 Hex Head Cap Screw  
M4 Fender Washer  
9
--  
--  
-
-
-
1
1
2
115VAC Heater - Bracket Assembly  
M3 x 20 Screw  
Rivet, 5/32in. x 0.415in.  
-
3
315 2298 900  
315 2327 900  
-
-
-
5
17  
21  
22  
24VAC Heater-Bracket Assembly Kit - 315 2810 001  
9
--  
--  
-
-
-
1
1
2
24VAC Heater - Bracket Assembly  
M3 x 20 Screw  
Rivet, 5/32in. x 0.415in.  
115VAC Rail Assembly Kit - 315 2806 001  
6
7
-
-
-
-
-
-
1
1
1
3
7
1
Terminal Block  
230VAC Heater-Bracket Assembly Kit - 315 2811 001  
Rail-back Weldment  
9
--  
--  
-
-
-
1
1
2
230VAC Heater - Bracket Assembly  
M3 x 20 Screw  
Rivet, 5/32in. x 0.415in.  
8
Ground Spring  
16  
17  
18  
M4 x 16 Low Socket Cap Screw  
M4 Internal Star Lock Washer  
#6-32 x 5/8in. Bosch Flat Head  
Screw  
Two-Eye Cable Assembly Kit - 315 2812 001  
10  
13  
14  
15  
-
-
-
-
1
1
2
2
2 Eye Cable Assembly  
M6 Flat Washer  
M6 Thin Hex Nut  
M6 Serrated Lock Washer  
19  
20  
23  
--  
-
-
-
-
2
3
3
1
#8 Ring Tongue Terminal  
M3 Philips Pan Head Screw  
M4 Philips Pan Head Screw  
115 VAC NEMA 5-15R  
Receptacle  
Faceplate Kit - 315 2813 001  
4
5
12  
24  
315 2300 900  
315 2327 900  
-
-
2
1
1
2
Retaining Ring 500  
EP O-ring 248  
Faceplate  
24VAC Rail Assembly Kit - 315 2807 001  
6
7
-
-
-
-
-
-
1
1
1
3
7
1
Terminal Block  
Rail-back Weldment  
Rubber Pull Seal  
8
Ground Spring  
16  
17  
18  
M4 x 16 Low Socket Cap Screw  
M4 Internal Star Lock Washer  
#6-32 x 5/8in. Bosch Flat Head  
Screw  
Housing Assembly - 315 2814 001  
4
11  
315 2300 900  
-
2
1
Retaining Ring 500  
Housing Assembly  
19  
20  
23  
-
-
-
2
3
3
#8 Ring Tongue Terminal  
M3 Philips Pan Head Screw  
M4 Philips Pan Head Screw  
Hardware Kit - 315 2348 001  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
24  
--  
-
-
-
-
-
-
-
-
-
-
-
-
-
3
4
4
1
1
1
1
1
1
1
2
2
2
Cable Tie  
3.2mm Plastic Spacer  
0.4mm Plastic Spacer  
1/4-20 x 3/8in. Button Head Screw  
1/4-20 x 1/2in. Button Head Screw  
1/4-20 x 5/8in. Button Head Screw  
1/4-20 x 3/4in. Button Head Screw  
1/4-20 x 7/8in. Button Head Screw  
3/8in. NPT Plug  
230VAC Rail Assembly Kit - 315 2808 001  
6
7
-
-
-
-
-
-
1
1
1
3
7
1
Terminal Block  
Rail-back Weldment  
8
Ground Spring  
16  
17  
18  
M4 x 16 Low Socket Cap Screw  
M4 Internal Star Lock Washer  
#6-32 x 5/8in. Bosch Flat Head  
Screw  
Small Flex Fitting  
Large Flex Fitting  
19  
20  
23  
--  
-
-
-
-
2
3
3
1
#8 Ring Tongue Terminal  
M3 Philips Pan Head Screw  
M4 Philips Pan Head Screw  
230VAC Schuko In-Line  
Receptacle  
Pull Seal  
Nylon Bushing  
Americas  
Bosch Security Systems  
130 Perinton Parkway  
Europe, Middle East, Africa  
Bosch Security Systems B.V.  
P.O. Box 80002  
Asia-Pacific  
Bosch Security Systems Pte Ltd  
38C Jalan Pemimpin  
Fairport, New York, 14450, USA  
Phone: +1 (585) 223 4060  
5600 JB Eindhoven, The Netherlands  
Singapore 577180, Singapore  
Phone: +65 319 3488  
Fax:  
+1 (585) 223 9180  
Fax:  
+65 319 3499  
© 2005 Bosch Security Systems GmbH  
3935 890 06612 05-04 | Updated January 26, 2005 | Data subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blanco Indoor Furnishings 157 122 User Manual
BMW Automobile Parts 2001 2006 User Manual
Bosch Appliances Security Camera LTC 9384 User Manual
Bradford White Corp Water Heater Eco Defender User Manual
Brainboxes Network Card BL 500 User Manual
Briggs Stratton Pressure Washer 020225 0 User Manual
Brother Printer QL 560 User Manual
Brother Sewing Machine LX2500 User Manual
Carrier Heat Pump 28QX User Manual
CFM Fan AIB 1006 User Manual