Bosch Appliances Network Router ATM POS Bridge User Manual

ATM/POS bridge  
EN Installation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
iii  
ATM/POS Bridge  
Installation manual  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
iv  
IMPORTANT SAFETY INSTRUCTIONS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with a dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the  
manufacturer's instructions.  
8. Do not install near any heat sources such as radiators, heat registers,  
stoves, or other apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug.  
A polarized plug has two blades with one wider that the other. A grounding-  
type plug has two blades and a third grounding prong. The wide blade or  
third prong are provided for your safety. If the provided plug does not fit into  
the outlet, consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at  
plugs, convenience receptacles, and the point where they exit from the  
apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table  
specified by the manufacturer, or sold with the apparatus.  
When a cart is used, use caution when moving the cart/  
apparatus combination to avoid injury from tip-over.  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
v
13. Unplug this unit during lightning storms or when unused for long periods  
of time.  
14. Refer all servicing to qualified service personnel. Servicing is required  
when the apparatus has been damaged in any way, such as power-supply  
cord or plug is damaged, liquid has been spilled or objects have fallen into  
the apparatus, the apparatus has been exposed to rain or moistue, does not  
operate normally, or has been dropped.  
CAUTION  
This unit has a battery inside the enclosure. Risk of explosion if battery is  
replaced by incorrect type. Dispose of used battery in an environmentally  
friendly way. Do not dispose of the battery with other solid waste.  
Remark  
Bosch has a strong commitment towards the environment. This unit has been  
designed to respect the environment as much as possible.  
FCC & ICES INFORMATION  
(U.S.A. and Canadian Models Only)  
This is a Class B product. This device complies with Part 15 of the FCC  
rules. Operation is subject to the following two conditions: (1) this device  
may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired  
operation.  
CAUTION  
Use of controls or adjustments or performance of procedures other than  
those specified herein may result in hazardous radiation exposure.  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
vi  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 1  
ATM/POS bridge  
Table of Contents  
1.  
ATM/POS bridge ................................................................................................... 3  
1.1 Package contents...................................................................................... 3  
1.2 Supported protocols................................................................................. 3  
1.3 Mounting...................................................................................................... 3  
1.4 Applications ................................................................................................ 4  
1.5 Connections................................................................................................ 5  
Configuration........................................................................................................... 7  
2.1 How to set up a HyperTerminal session .............................................. 7  
2.2 Configuration menus................................................................................. 8  
Connectors........................................................................................................... 11  
Troubleshooting................................................................................................... 12  
Technical specifications .................................................................................... 13  
2.  
3.  
4.  
5.  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 2  
SAFETY PRECAUTIONS  
CAUTION  
RISK OF ELECTRIC  
SHOCK. DO NOT OPEN!  
CAUTION: TO REDUCE THE RISK OF ELECTRICAL  
SHOCK, DO NOT OPEN COVERS. NO USER  
SERVICEABLE PARTS INSIDE. REFER SERVICING TO  
QUALIFIED SERVICE PERSONNEL.  
This label may appear on the bottom of the unit due to space limitations.  
The lightning flash with an arrowhead symbol within an  
equilateral triangle is intended to alert the user to the  
presence of uninsulated "dangerous voltage" within the  
product's enclosure that may be of sufficient magnitude  
to constitute a risk of electric shock to persons.  
The exclamation point within an equilateral triangle  
is intended to alert the user to presence of important  
operating and maintenance (servicing) instructions in  
the literature accompanying the appliance.  
WARNING  
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO  
NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE  
AND OBJECTS WITH LIQUIDS, SUCH AS VASES, SHOULD  
NOT BE PLACED ON THIS APPARATUS.  
Attention: Installation should be performed by  
qualified service personnel only in accordance with the  
National Electrical Code or applicable local codes.  
Power Disconnect. Units have power supplied  
whenever the power cord is inserted into the power  
source. The power cord is the main power disconnect  
for all units.  
The socket outlet shall be installed near the  
equipment and shall be easily accessible.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 3  
1. ATM/POS bridge  
The ATM/POS bridge connects a Point-of-Sale (POS) or an Automatic Teller Machine  
(ATM) to a Bosch digital video recorder so that transactional data from these units can  
be stored and displayed with associated video recordings.  
1.1 Package contents  
Check the package for following items:  
ATM/POS bridge  
External DC power supply  
Mounting kit  
2 connection cables and 1 console cable (with two 9-pole SubD connectors)  
Installation manual (this manual)  
1.2 Supported protocols  
The ATM/POS bridge is designed to operate with many different terminals. If you have  
any questions regarding the suitability of the firmware for your terminal or any other  
enquiries, contact your Bosch representative.  
1.3 Mounting  
Using the screws provided, attach the two mounting brackets to the sides of the bridge.  
Secure the brackets to a solid fixture.  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 4  
1.4 Applications  
The following illustration shows an example of how a bridge is used in a network of digital  
video recoders and POS terminals.  
The following illustration shows an example of how a bridge is used in a network of digital  
video recoders and ATM terminals.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 5  
1.5 Connections  
Using the supplied cables, connect the bridge as follows:  
1. Connect the supplied DC power adapter unit to the DC power input connector of  
the bridge.  
2. Connect the RJ45 connector of the bridge via a straight Ethernet CAT5 network  
cable to a network switch or hub that supports 10BaseT. Alternatively, the bridge can  
be connected directly to the digital video recorder via a cross-over cable.  
3. To configure the bridge, use an RS232 cable to connect the COM3 (console) port to  
the serial port of a PC. If you use the RS232 console cable supplied with the bridge,  
ensure that the bridge is powered before connecting the cable.  
COM 3 (console) RS232 connector  
DC Power input connector  
Ethernet RJ45 connector  
Activity indicator  
COM 4 RS485 connector  
COM 2 RS232 connector  
COM 1 RS232 connector  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 6  
4. Connect your terminal to COM port 1, 2, 3 or 4 of the bridge using the supplied  
cable. Choose the COM 4 port on the bridge if your connection protocol is RS485.  
Normally, you would use the supplied splitter cable to make this connection. For  
example, you remove the existing cable that connects your terminal to the  
printer. Use the supplied splitter cable to connect the terminal to the printer.  
The third connector of the splitter cable then connects to the supplied  
connection cable which connects to the bridge.  
POS terminal  
Supplied splitter  
cable  
Printer  
Supplied  
connection cable  
Digital  
Video  
Recorder  
ATM/POS  
bridge  
Ethernet  
cross-over  
cable  
To select the communication parameters for the ports and the network parameters, use a  
PC to start a configuration session as described below. The activity LED lights when the  
bridge is active.  
Note  
To download firmware to the bridge you must use the supplied RS232 cable connected  
to the COM3 (console) port. In this situation the cable must be connected to the bridge  
before it is powered.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 7  
2. Configuration  
The ATM/POS bridge is configured via a PC HyperTerminal session. The PC is  
connected via a COM serial port to the COM 3 (console) port of the bridge. Start a  
HyperTerminal session on the PC to get access to the configuration menu of the bridge.  
2.1 How to set up a HyperTerminal session  
1. Start the PC HyperTerminal program in Windows (normally available under  
Start_Programs_Accessories_Communications).  
2. Enter a name for the HyperTerminal session and click OK.  
3. For the connection, select the COM port number of the PC.  
4. Fill in the following values for the COM port properties and click OK:  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 8  
5. If the bridge is switched on, a welcome message is shown on the screen. This  
message prompts you to press the F1 key (a function key on your keyboard).  
6. Press the F1 key; the screen displays the System Options Menu.  
7. To configure the bridge, navigate through the menus using the numeric keys on your  
keyboard to select menu items.  
2.2 Configuration menus  
2.2.1 System options menu  
The system options menu has 6 items:  
1. Network Setup  
2. Communication Channels  
3. Terminal Setup  
4. Simulation mode  
5. Recording Language  
6. Service Menu  
Network Setup  
The Network Setup submenu enables you to configure network settings and enter a  
bridge name:  
1
2
3
4
5
6
Bridge Name  
BRIDGE-01  
192.168.10.2  
255.255.255.0  
0.0.0.0  
I P-Address  
Subnet Mask  
Default Gateway  
Recorder TCP Port  
Service TCP Port  
4200 (default)  
4201 (default)  
The MAC Address of the bridge is shown but cannot be changed.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 9  
Communication Channels  
In the Communication Channels submenu you can select one of the four COM ports to  
configure. The submenu that appears depends on the setting of the Comport Mode. Enter  
the parameters that are required for your terminal.  
1
3
4
5
6
7
Comport Mode  
Baudrate  
Databits  
Asynchronous  
9600  
8 bits  
Parity  
None  
Stop bits  
1bit  
Flow Control  
Off  
Terminal Setup  
In the Terminal Setup submenu you can select one of the four connected terminals to  
configure. Enter a terminal name and select the type of device connected to your  
terminal. Contact your local sale representative if your device is not listed in the menu  
for selection. Our firmware is continously extended with new options.  
1
2
3
4
Name  
TERMINAL-01  
Epson TM-T88III (example)  
Com 1 - RS232  
0
Device  
Comm Channel  
Address  
Simulation Mode  
The Simulation Mode is used to test the connection between the bridge and the digital  
recorder. If this mode is selected, sample data is sent from the bridge to the digital  
recorder.  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 10  
Recording Language  
Select the same language that is set on the connected digital recorder. This ensures that  
characters are displayed correctly. The configuration menu language continues to be  
English.  
Service Menu  
The Service Menu is used to restore the bridge to factory defaults, to reset the bridge, or  
to do diagnostics.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 11  
3. Connectors  
The four COM connectors are all 9-pin SubD-type male connectors.  
5
9
1
6
The following table lists the signals and pin numbers for the four ports.  
COM 3  
(console)  
RS 232  
COM 1  
RS 232  
COM 2  
RS 232  
COM 4  
RS 485  
Pin  
1
2
3
4
5
6
7
8
9
Rx  
Tx  
Rx  
Tx  
Rx  
Tx  
D2+  
D2-  
GND  
GND  
GND  
GND  
RxC  
TxC  
RxC  
TxC  
INIT  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 12  
4. Troubleshooting  
If you are unable to capture transaction data, perform the following steps:  
1. Recheck your cables.  
2. Check your TCP/IP network connection with the ATM/POS bridge. Check your  
gateway and subnet mask settings, they must match the digital recorder settings.  
3. If the recorder has established communication with your bridge and you still cannot  
capture the transaction data, use the simulation mode of the bridge in the System  
Options Menu. The bridge will send sample transactions to the recorder in this  
mode.  
4. Check the COM ports settings in your bridge. If the transaction data is being  
recorded, but shows the wrong characters, check the COM port settings. The  
language setting must be the same as the recorder language setting.  
5. If your recorder requires an ATM/POS software license (for example, the Divar 2  
digital versatile recorder), please check if this license is enabled in the System  
Settings - Licenses submenu of the Divar.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 13  
5. Technical specifications  
Electrical  
Power supply:  
External DC power supply (supplied)  
Input: 100-240 VAC; 150mA, 50/60Hz  
Output: 12 VDC; 450mA  
Connector:  
DC jack, positive center pin; 10-30 VDC; 2W  
Mechanical  
Dimensions:  
Weight:  
152 x 110 x 35 mm / 5.98 x 4.33 x 1.38 inch  
Approx. 0.6 kg / 1.3 lbs  
Supplied  
Mounting kit:  
Interface  
Ethernet:  
RJ45 shielded, 10 BaseT  
Com 1 port:  
9-pin SUBD male connector; RS232 synchronous or  
asynchronous signals according to EIA/TIA-232-F  
Com 2 port:  
9-pin SUBD male connector; RS232 synchronous or  
asynchronous signals according to EIA/TIA-232-F  
Com 3 (console) port:  
Com 4 port:  
9-pin SUBD male connector; RS232 asynchronous signals  
according to EIA/TIA-232-F  
9-pin SUBD male connector; RS485 asynchronous  
Environmental  
Temperature:  
Operating: +0°C to +45°C (+32°F to +113°F)  
Storage: -25°C to +70°C (-13°F to +158°F)  
Operating: < 80% non-condensing  
Relative humidity:  
Storage: < 90% non-condensing  
Bosch SecuritDyoSwynslotaedmfrsom Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
EN | 14  
Electromagnetic Compatibility  
EMC requirements:  
USA: FCC Part 15, Class B  
EU: EMC directive 89/336/EEC  
Immunity: EN50130-4  
Emission: EN55022 Class B  
Harmonics: EN61000-3-2  
Voltage fluctuations: EN61000-3-3  
USA: UL60950  
Safety:  
EU: EN60950  
Canada: CAN/CSA - C22.2 - 60950-00  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATM/POS bridge | Installation Manual  
Bosch Sicherheitssysteme GmbH  
Ludwig-Bölkow-Allee  
Bosch Security Systems B.V.  
P.O. Box 80002  
85521 Ottobrunn  
5600 JB Eindhoven  
Germany  
The Netherlands  
3122 165 2272.2  
© 2004 Bosch Security Systems B.V.  
Subject to change. Printed in The Netherlands.  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Film Camera F1D084vea2 User Manual
Belkin Network Card P75481 User Manual
Belkin Server 5000HQ User Manual
Black Box Barcode Reader TS1000A R5 User Manual
Black Decker Power Screwdriver 1VPX User Manual
Black Decker Saw 3004 User Manual
Bosch Appliances Water Heater GWH 425 HN L User Manual
Bosch Power Tools Saw F 012 380 002 3800 User Manual
Brinly Hardy Lawn Mower Accessory SAT 400 BH User Manual
Casio Battery Charger HA A34AT User Manual