Bosch Appliances Home Security System APC AMC2 4W User Manual

AMC2 4W  
APC-AMC2-4W | APC-AMC2-4WCF | APC-AMC2-4WUS  
en Installation manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
| en  
3
Remarks  
This hardware is part of a security system. Access shall be lim-  
ited to authorized persons only.  
Some states do not allow the exclusion or limitation of implied  
warranties, or limitation of liability for incidental or consequen-  
tial damages, so the above limitation or exclusion might not  
apply to you.  
Bosch Security Systems retains all rights not expressly granted.  
Nothing in this license constitutes a waiver of Bosch’s rights  
under the U.S. Copyright laws or any other federal or state law.  
If you have any questions concerning this license, please, write  
to:  
Bosch Access Systems GmbH  
Adenauerstr. 20 / A3  
D-52146 Würselen  
Germany.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
en |  
AMC2 4W  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
1
Please read carefully | en  
7
Please read carefully  
1.1  
Explanation of Used Symbols  
Throughout this document, helpful tips, important notes, cau-  
tions and warnings will be presented for the reader to keep in  
mind. These appear different from the rest of the text as fol-  
lows:  
CAUTION! or WARNING!  
These warn the operator that damage to the program or equip-  
ment might occur.  
!
NOTE!  
Important Notes must be followed for successful operation  
and programming. Tips and shortcuts might also be included  
here.  
1.2  
Internet  
If you are interested in further information on this product or  
information on other products, please, refer to our website at  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
8
en | Safety Instructions  
AMC2 4W  
2
Safety Instructions  
2.1  
Important Safety Notes  
1. Read, Follow, and Retain Instructions - All safety and  
operating instructions must be read and followed properly  
before putting the unit into operation. Retain instructions  
for future reference.  
2. Consider all Warnings - Adhere to all warnings on the unit  
and in the operating instructions.  
3. Accessories - Use only accessories recommended by the  
manufacturer or those sold with the product. Accessories  
not recommended by the manufacturer shall not be used,  
as they may cause hazards.  
4. Installation Precautions - Do not place this unit on an  
unstable stand, tripod, bracket, or mount. The unit may  
fall, causing serious injury to persons and damage to the  
unit. Mount the unit according to the manufacturer’s  
instructions.  
5. Service - Do not attempt to service this unit by yourself.  
Opening or removing covers may expose you to dangerous  
voltages or other hazards. Refer all servicing to qualified  
service personnel.  
6. Damage Requiring Service - Disconnect the unit from the  
main AC or DC power source and refer servicing to quali-  
fied service personnel under the following conditions:  
When the power supply cord or plug is damaged.  
If liquid has been spilled or an object has fallen into  
the unit.  
If the unit has been exposed to water and/or inclem-  
ent weather (rain, snow, etc.).  
If the unit does not operate normally, when following  
the operating instructions. Adjust only those controls  
specified in the operating instructions. Improper  
adjustment of other controls may result in damage,  
and require extensive work by a qualified technician  
to restore the unit to normal operation.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Safety Instructions | en  
9
If the unit has been dropped or the cabinet damaged.  
If the unit exhibits a distinct change in performance,  
this indicates that service is needed.  
7. Replacement Parts - When replacement parts are  
required, the service technician shall use replacement  
parts that are specified by the manufacturer. Unauthorized  
substitutions may result in fire, electrical shock or other  
hazards.  
8. Safety Check - Upon completion of service or repair work  
on the unit, ask the service technician to perform safety  
checks to ensure that the unit operates properly  
9. Power Sources - Operate the unit only from the type of  
power source indicated on the label. If unsure of the type  
of power supply to use, contact your dealer  
For units intended to operate from battery power,  
refer to the operating instructions.  
For units intended to operate with External Power  
Supplies, use only the recommended approved power  
supplies.  
For units intended to operate with a limited power  
source, this power source must comply with EN/UL  
60950. Substitutions may damage the unit or cause  
fire or shock.  
For units intended to operate at 12/24V DC normal  
input voltage is 12/24V DC. Voltages applied to the  
unit’s power input shall not exceed 15/30V DC.  
10. Lightning - For added protection during a lightning storm,  
or when this unit is left unused for long periods of time,  
disconnect the unit from power. This will prevent damage  
to the unit due to lightning and excessive power line  
surges.  
11. Restricted Access Locations are required for the installa-  
tion.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 en | Safety Instructions  
AMC2 4W  
2.2  
FCC & ICES Information  
This device complies with part 15 of the FCC rules. Operation is  
subject to the following two conditions: (1) This device may not  
cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause  
undesired operation.  
This equipment has been tested and found to comply with the  
limits for a Class B digital device, pursuant to part 15 of the  
FCC rules. The limits are designed to provide reasonable pro-  
tection against harmful interference in a residental installation.  
This equipment generates, uses and can radiate radio fre-  
quency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio com-  
munications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception,  
which can be determined by turning the equipment off and on,  
the user is encouraged to try to correct the interference by one  
or more of the following measures:  
1. Reorient or relocare receiving antenna  
2. Increase the separation between the equipment and the  
receiver  
3. Connect the equipment into an outlet on a circuit different  
from that to which the receiver is connected  
4. Consult the dealer or an experienced radio/TV technician  
for help  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AMC2 4W  
Safety Instructions | en 11  
2.3  
Safety Precautions  
Read instructions!  
Before working with the AMC2 4W, read these instructions  
carefully. Make sure you have understood all information  
described in this document.  
!
!
Warning! Risk of electric shock!  
External power supplies must be installed and put into service  
by qualified personnel. Compliance with the relevant regula-  
tions must be ensured.  
Warning! Risk of damaging equipment!  
Always switch off power of the AMC2 4W before mod-  
ifying the installation.  
!
!
Do not connect or disconnect plug connectors, data  
cables or screw connectors while power is on!  
Health and Safety  
Installation of the AMC2 4W must comply with any local fire,  
health and safety regulations. A secured door that may be part  
of an escape route from an area must be installed with:  
A fail-safe lock. So that the door will be released if  
power fails. Ideally, a magnetic lock should be used as  
these are less likely to jam or seize.  
A normally-closed break-glass or manual pull in the  
lock supply wiring, so that in an emergency the fail-  
safe lock can be immediately powered down.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
12 en | Safety Instructions  
AMC2 4W  
CAUTION!  
Disconnect both AC and battery power supply before working  
on the controller.  
!
!
Warning! Risk of damage!  
Protect the hardware from electrostatic discharge by observing  
ESD instructions before unpacking or touching connectors or  
electronics.  
CAUTION: Lithium Battery  
Danger of explosion if battery is replaced incorrectly. Replace  
only with the same type as recommended by the manufacturer.  
Dispose used batteries according to the battery manufacturer’s  
instructions.  
!
2.4  
Unpacking  
Check the packaging for visual damage. If anything has been  
damaged during transport, make the transport agency aware of  
this.  
Carefully unpack the unit. This is an electronic device that must  
be handled with care to avoid damage. Do not attempt to put  
the unit into operation if components are damaged.  
If parts are missing, inform your customer service representa-  
tive or a Bosch Security Systems salesperson. The shipping car-  
ton is the safest transport container for the unit. Store it and  
the other packaging material for future use. If the unit has to be  
sent back, use the original packaging.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AMC2 4W  
3
Introduction | en 13  
Introduction  
3.1  
Description of the AMC2 4W  
The AMC2 4W is equipped with four independent interfaces for  
Wiegand type readers. By that it is able to control two doors  
with a reader in each direction and up to four doors with a  
reader in one direction only.  
Fig. 3.1 The Access Modular Controller AMC2 4W  
All necessary information for access verification is stored in a  
battery buffered on-board memory and a Compact Flash (CF)  
memory card. This guarantees autonomous access decisions  
and complete access registrations even if the management host  
system is offline. The built in compact flash adapter provides  
adequate storage capability for cardholders and events.  
The AMC2 4W electronic is completely covered by a plastic  
housing. The LC Display provides all important status informa-  
tion.  
Using the AMC2 4W gives you the full functionality and the  
offline capability of a complete access control system on each  
room. This leads to an excellent reliability and a very high  
redundancy without paying extra money.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
14 en | Introduction  
AMC2 4W  
Fig. 3.2 The AMC2 4W in a four door safety lock  
The AMC2 4W can communicate upstream to the host com-  
puter via eight RS-485 multi-dropped, RS-232 or 10/100 Mbit/s  
Ethernet. It has eight analog input devices and eight relay out-  
puts. With its analog input devices, the AMC2 4W verifies, for  
example, if a lock is closed or open. The relay outputs can be  
used to activate lock mechanisms if access is granted, or acti-  
vate an external alarm system if an intrusion or system alert is  
detected. If the eight input and output on board are not enough  
to configure the system up to three additional extensions  
(AMC2 8I-8O-EXT or AMC2 16I-16O-EXT) can be connected. The  
extensions offer 8 or 16 additional inputs and outputs.  
The setup procedure for an AMC2 4W is very simple and  
extremely fast by the use of door templates. Once selected, all  
the inputs and outputs are predefined. This settings can be  
changed using the Device Editor of the BIS Configuration  
Browser in that way to choose every free contact of the  
AMC2 4W or an connected extension.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
Introduction | en 15  
3.2  
Equipment Configuration  
Fig. 3.3 Upper circuit board with display (top side)  
1. Internal tamper contact  
2. DIL switch for RS-485 address selection, protocol and RS-  
232/RS-485 selection  
3. Lithium battery for buffering of static RAM and real time  
clock (RTC). The battery shall be replaced by qualified per-  
sonnel every ten years or if indicated by an appropriate  
event.  
4. Reset push button - available by using the srew driver  
5. LC Display  
6. Push button to select the display view - available by using  
the push button on the top of the housing  
7. Jumper: Potential equalization between different mass sys-  
tems and protective earth (shield)  
8. Jumper: interface selector RS-485 Host connection, RS-  
485 two wire or RS-485 four wire (depends on external  
wiring)  
9. Configurable RS-485 host interface (pluggable screw con-  
nector)  
10. Docking station for the compact flash  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
16 en | Introduction  
AMC2 4W  
11. Configurable RS-232 host interface (ribbon cable connec-  
tor)  
12. Configurable 10/100 Mbit/s Ethernet interface  
Fig. 3.4 Overview - Interfaces  
13. RS-485 extension module bus (Pluggable screw connector)  
14. External tamper contact (Pluggable screw connector)  
15. Power supply (Pluggable screw connector)  
16. Wiegand interfaces for up to 4 card readers (Pluggable  
screw connector)  
17. Connectors for eight analog inputs (Pluggable screw con-  
nector)  
18. Connectors for eight relay outputs (Pluggable screw con-  
nector)  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
Introduction | en 17  
Fig. 3.5 Jumper at the bottom side  
19. Jumper: Selector for either potential free relay output or  
powered by AMC2 4W internal power supply (wet/dry con-  
tacts).  
20. Jumper: Potential equalization between different mass  
systems and protective earth (shield)for the extension  
interface.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18 en | Introduction  
AMC2 4W  
3.3  
Performance Characteristics  
Intelligent access manager for 1 ... 4 entrances (e.g. doors,  
man traps, barriers)  
Host address selectable via DIL sliding switch  
Four possible configurable host interfaces:  
RS-485 2-wire  
RS-485 4-wire  
RS-232  
Ethernet  
Four peripheral input devices via Wiegand interface  
Eight relay outputs  
potential-free or  
with internal power supply  
Eight analog inputs with internal power supply  
Battery buffered SRAM and real time clock (RTC)  
Pluggable Compact Flash from 64 MB to 1024 MB  
LC Display  
Transfer rate host interface RS-485: 38,4 kBit/s  
Transfer rate host interface RS-232: 38,4 kBit/s  
Transfer rate host interface Ethernet: 10/100 Mbit/s  
Self controlling transfer-receive-switching  
Power supply for internal electronics: 10V - 30VDC - max.  
5A  
Tamper contact for internal and external covers  
The AMC2 4W is to be used with power supply  
AMC PBC-60 (F.01U.026.573) with integrated UPS.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Introduction | en 19  
3.4  
System Overview  
The Access Controller AMC2 4W is connected between the  
management host system and different peripheral devices. By  
default a management host system is connected via Ethernet. A  
management host connection via RS-485 or RS-232 is also pos-  
sible.  
Fig. 3.6 System overview  
The number of controllers in one system is limited to 200.  
Corresponding to the available interfaces one AMC can be con-  
nected to each COM-Port using RS-232 mode. In RS-485 mode  
up to eight access controllers can be combined on one party  
line.  
Via Wiegand interfaces up to four peripheral devices can be  
connected to each AMC2 4W. The interfaces are point-to-point  
connections - this means that only one reader can be connected  
to one interface.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
20 en | Technical Data  
AMC2 4W  
4
Technical Data  
Hardware  
Integrated Microcontroller (32Bit, 30MHz)  
SRAM (256MB)  
Serial EEPROM  
RTC  
Pluggable Compact Flash from 64 MB up  
to 1024 MB  
Battery for SRAM and real time clock  
(RTC)  
Host address selectable via DIL sliding  
switch or software  
Host interface  
RS-485 2-wire or 4-wire  
Transfer rate: 38,4 kBit/s  
(No parity, 8 Bit, 1 Stopbit)  
RS-232  
Transfer rate: 38,4 kBit/s  
(No parity, 8 Bit, 1 Stopbit)  
Ethernet 10/100 Mbit/s  
Four Wiegand interfaces for card readers  
Eight relay outputs  
max. switching power: 37,5VA  
max. switching voltage: 30V DC  
max. switching current: 1,25A  
Eight analog inputs with sabotage monitor-  
ing  
Tamper contact for enclosures  
Power supply AMC: 10V – 30V DC  
Display 64,8 mm x 13,9 mm (2.551 x 0.547 in.)  
1 line, 16 characters  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AMC2 4W  
Technical Data | en 21  
Power con-  
sumption  
AMC: 5VA  
Peripheral devices:  
using the AMC PBC-60  
up to 55VA  
constant load: 25VA  
Connectors  
Pluggable screw connectors  
IP30  
Protection  
Class  
Environment 0°C to 45°C  
temperature  
Humidity  
Up to 95%, without condensation  
Housing mate- ABS with OC (UL 94 V-0)  
rial  
Dimensions  
(W/H/D) 232mm x 90mm x 63mm (8.9 x 3.5 x  
2.4 in.)  
Weight  
app. 0,53 kg (0.9 pounds)  
CAUTION!  
The voltage drop from the power supply to the AMC has effect  
on the AMC-Interfaces. Their sum shall be less than 2V!  
!
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22 en | Installing  
AMC2 4W  
5
Installing  
5.1  
Mounting  
The AMC2 4W can be attached on a standard 35 mm (1.377 in.)  
mounting rail via a snap-in mechanism. Attach the AMC2 4W  
into the upper edge of the mounting rail, then push down the  
AMC2 4W and snap it onto the rail by pushing it towards the  
back.  
Fig. 5.1 Mounting the AMC2 4W on a mounting rail  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AMC2 4W  
Installing | en 23  
5.2  
Demounting  
NOTE!  
To remove the AMC2 4W from a mounting rail, first, remove all  
pluggable screw connectors.  
Push down the AMC2 4W until it snaps out of the mounting rail.  
Pull the lower end of the AMC2 4W from the mounting rail.  
Fig. 5.2 Demounting the AMC2 4W from a mounting rail  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
24 en | Installing  
AMC2 4W  
5.3  
Opening the AMC2 4W Case  
NOTE!  
To open the AMC2 4W, first, remove all pluggable screw con-  
nectors at least the host connection.  
The AMC2 4W case consists of a top cover mounted with a two-  
point snap-in closure on a ground chassis. To open the  
AMC2 4W push down the two snap-ins with a srew driver. After  
that the cover can be moved to bottom.  
Fig. 5.3 Opening the AMC2 4W case  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AMC2 4W  
Installing | en 25  
5.4  
Cabling  
CAUTION!  
The cables used in the AMC2 4W access control system are not  
prone to electrical interference. However, you should avoid  
routing cables close to heavy load switching cables and equip-  
ment. If this is unavoidable, cross the cable at right angles every  
1 to 2 m (3 to 6 ft) to reduce interference.  
!
Grounding and Shielding  
The main grounding point at the AMC2 4W will be connected  
with pin 2 of the power supply connector - see Figure 7.6.  
It is good practice to shield all wires carrying low level signals.  
The AMC2 4W enables you to set up a central ground or shield-  
ing point, simply by setting a couple of jumpers. Set these  
jumpers only if ground or shield is not connected otherwise.  
WARNING!  
Risk of damaging equipment!  
When using multiple AMC2 4W devices, set the ground main  
jumper only once to assure a central point star connection.  
!
5.4.1  
Conductor data for connection to power supply  
For short distances below 25m (75 feet) use AWG18 conduc-  
tors. For higher distances install an additional power supply  
close to the AMC.  
Please, calculate the voltage drop by checking the conductor  
specifications for characteristic resistance values. The voltage  
drop shall not exceed 2V.  
Example:  
Length = 100m/328 ft  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
26 en | Installing  
AMC2 4W  
U = 12V, I = 1A, maximum V  
= 2V  
Drop  
1000 ft  
6,385  
km  
or 20,948  
i.e. R  
(acc. specs) =  
AWG18  
km  
V
V
= 20,948  
x 0.1 km x 1A = 2.1V  
x 328 ft x 1A = 2.1V  
Drop  
1000 ft  
6,385  
=
Drop  
Critical condition! Install the power supply closer to the con-  
troller.  
NOTE!  
These specifications aim for readers, relay outputs, and exten-  
sions.  
For inputs there are other value to keep in mind - see therefore  
5.4.2  
Grounding and Shielding the Host Interface  
Fig. 5.4 Location of ground jumper RS-485 host interface  
The jumper setting A1 shows the delivery status.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AMC2 4W  
Installing | en 27  
NOTE!  
Generally the following counts:  
If the devices have an own power supply, the shield will be  
connected on one point, only.  
The free end should be protected to avoid connections.  
If the device will be provided by an other one, the shield  
have to connect on both sides.  
WARNING!  
Take care that there are no grounding loops.  
Setting jumper JP1 connects the internal ground of the  
AMC2 4W to the ground of the RS-485 host interface. Jumper  
JP2 manages the PAG.  
Settings jumper JP1:  
If the ground conductor and the shield on the host are not con-  
nected and ...  
no partyline exists, the jumper JP1 is set (= A2)  
a partyline exists, ...  
the jumper JP1 is set at the first device, only (= A2)  
Settings jumper JP2:  
If the ground conductor and the shield on the host are not con-  
nected and ...  
no partyline exists, the jumper JP2 is set (= A3)  
a partyline exists and PAG is connected, ...  
the jumper JP2 is set at the first device, only (= A3)  
a partyline exists and PAG is not connected, ...  
the jumper JP2 is set at all devices (= A3)  
NOTE!  
If the AMC2 4W is set to RS-232 mode, Jumper JP1 (= A2) must  
be set.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28 en | Installing  
AMC2 4W  
5.4.3  
Grounding and Shielding the Extension Interface  
Fig. 5.5 Location of ground jumper bottom side  
Jumper B connects the internal ground of the AMC2 4W to the  
RS-485 ground of the slave interface. Jumper B shall only be  
set (B2) if the AMC2 4W powers all other peripheral devices  
which are directly connected to the AMC2 4W.  
5.5  
Connecting Power Supply  
Connect the power supply to the 7-pin pluggable screw connec-  
tor labeled with POWER on the upper case.  
NOTE!  
A complete connection diagram of the power supply connector  
is shown in Figure 7.6.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AMC2 4W  
Installing | en 29  
Fig. 5.6 Location of the power supply connector  
An external power supply (10 - 30V DC) must be connected for  
internal electronics at pin 1 (positive) and pin 3 (negative) of  
the pluggable screw connector.  
When using a shared 12V DC power supply for internal electron-  
ics and peripherals, pin 1 and pin 6 resp. pin 3 and pin 7 can be  
shortened.  
If an uninterruptible power supply (UPS) is used, the relay out-  
put for power good signals from the UPS is connected to the  
following pins:  
pin 4 and 7 for power good AC  
pin 5 and 7 for power good Battery  
pin 6 and 7 for power good DC  
Otherwise these pins must be short-circuited.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 en | Installing  
AMC2 4W  
5.6  
RS-485 Host Interface  
An RS-485 host system can consist of up to eight AMC2 4W  
controllers connected via 2- or 4-wire connection.  
Fig. 5.7 Configuration of a RS-485 host system  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Installing | en 31  
The following conditions apply for an RS-485 bus system:  
A bus system consists of a bus line and/or one or more  
branch lines.  
Cable lengths exceeding 100m or 300ft must be installed  
as bus lines.  
Branch lines are branching connections from a bus line.  
Peripheral devices are AMC2 4W which are connected to  
the host computer.  
Maximum cable length of a bus line must not exceed  
1200m or 4000ft.  
The cable length of branch lines must not exceed 100m or  
300ft.  
Any bus line conductor connects up to eight AMC2 4W. The  
maximum number of devices must not be exceeded.  
For longer bus lines connect the AMC2 4W to multiple  
AMC-MUX (-EXT) with the host.  
NOTE!  
Up to seven AMC-MUX-EXT can be connected to an AMC-MUX.  
Every module subjects the conditions above. Using the exten-  
sions you can’t connect more than eight AMC2 4W.  
To get more information about the AMC-MUX and the extension  
see the manual of these devices (F.01U.012.855).  
To use RS-485 mode at the AMC2 4W, connect the data cables  
to the pluggable screw connector of the RS-485 host interface.  
Set the connection mode of the RS-485 using the DIL switch of  
the AMC-MUX. Then set the RS-485 address via DIL switch or  
software and activate the RS-485 two-wire or four-wire mode  
via jumper settings on the AMC - see Figure 5.10 and  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
32 en | Installing  
AMC2 4W  
Fig. 5.8 RS-485 host interface  
5.6.1  
RS-485 Two Wire Connection  
Fig. 5.9 Connection scheme of a RS-485 two wire connection  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Installing | en 33  
Fig. 5.10 Settings for RS-485 two wire connections  
For RS-485 two wire connection set the AMC-MUX DIL-Switch  
at the position 3, 7 and 8 to ON. On the upper side of the AMC  
panel put the jumper on the two pins on the right hand side of  
the connector 8 (see also: Figure 3.3). Set the RS-485 address  
of the AMC using the DIL-Switch - see Section 5.6.3 DIL Switch  
5.6.2  
RS-485 Four Wire Connection  
Fig. 5.11 Connection scheme of an RS-485 four wire connection  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
34 en | Installing  
AMC2 4W  
Fig. 5.12 Settings for RS-485 four wire connection  
For RS-485 four wire connection set the AMC-MUX DIL-Switch  
at the position 3, 5 and 6 to ON. On the upper side of the AMC  
panel put the jumper on the two pins on the right hand side of  
the connector 8 (see also: Figure 3.3). Set the RS-485 address  
of the AMC using the DIL-Switch - see Section 5.6.3 DIL Switch  
NOTE!  
A complete connection diagram of the RS-485 host interface is  
shown in Figure 7.2.  
5.6.3  
DIL Switch Address Selector  
The first four DIL switches for address selection define the RS-  
485 address of the AMC2 4Win a RS-485 bus system. Switch 5  
selects on of the two different protocols, SDEB and BPA  
(according to DIN6619). Switch 6 sets the connection to the  
host system to either RS-232 or RS-485.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
AMC2 4W  
Installing | en 35  
NOTE!  
Using Ethernet connection it is recommended to set switch 1 to  
ON (= delivery status)  
Using RS-232 connection the address must be set, which is con-  
figured in the Device Editor. Therefore this is a point-to-point  
connection the usually configured address will be 1 - so the  
switch 1 must be also set to ON.  
Fig. 5.13 Location of the RS-485 address selector  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36 en | Installing  
AMC2 4W  
DIL Switches  
Address  
1
2
3
4
none  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
1
2
3
4
5
6
7
8
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
Table 5.1 Setting the RS-485 address with the DIL switch  
DIL Switches  
Mode  
5
6
ON  
OFF  
SDEB  
BPA  
RS-232  
RS-485  
Table 5.2 Protocol and connection settings  
5.7  
RS-232 Host Interface  
The AMC2 4W offers an RS-232 serial interface to connect a  
host computer or serial modem.  
CAUTION!  
Cable length between two RS-232 COM serial interfaces must  
not exceed 15 meters (45 ft).  
!
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Installing | en 37  
Fig. 5.14 Location of the RS-232 serial interface  
The AMC is created like a PC, so you cannot build a 1:1 connec-  
tion, but cross the data wires using a null modem cable for  
example.  
NOTE!  
A complete connection diagram of the RS-232 host interface is  
shown in Figure 7.3.  
5.8  
Ethernet Interface  
The AMC2 4W offers an additional 10/100 Mbit/s Ethernet auto-  
sensing interface to connect to a local area network or host  
computer.  
CAUTION!  
Use either a CAT5 crossover cable to connect the AMC2 4W  
directly to a computer’s network interface or a standard CAT5  
patch cable to connect the AMC2 4W to a network hub or net-  
work switch.  
!
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
38 en | Installing  
AMC2 4W  
Fig. 5.15 Location of the Ethernet interface  
NOTE!  
After the connection of a new AMC in a network using DHCP it  
can take several time if the AMC is known on the remote server.  
This cause in the DNS cache of the lokal PC - it will be refreshed  
only after special duration.  
To speed up this procedure give in the following command in a  
command prompt:  
ipconfig /flushdns  
After this the AMC should be available by its name.  
NOTE!  
A complete connection diagram of the Ethernet host interface is  
shown in Figure 7.4.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
Installing | en 39  
5.9  
RS-485 Extension Module Bus  
The RS-485 Extension Module Bus expands the AMC2 4W with  
additional I/O modules (AMC2 8I-8O-EXT or AMC2 16I-16O-  
EXT). Up to three expansion modules can be connected to pro-  
vide additional in- and outputs, for example, for elevator con-  
trol.  
You can find further information about the extension boards in  
the installation manual of these modules (Order-no:  
F.01U.024.967)  
Fig. 5.16 Location of the RS-485 extension module bus  
NOTE!  
A complete connection diagram of the RS-485 extension mod-  
ule bus is shown in Figure 7.10.  
5.10  
Wiegand Interface for Card Readers  
The AMC2 4W has four Wiegand interfaces to integrate up to  
four card readers with Wiegand compatible interfaces. Each  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
40 en | Installing  
AMC2 4W  
interface is connected via a 10-pin pluggable screw connector  
(S2, S7, S14, and S19).  
Fig. 5.17 Location of the Wiegand interfaces for external devices  
The interfaces are point-to-point connections. You can connect  
only one reader to an interface - the cable length is limited to  
150 m (492 ft). Like the numbering of the interfaces the reader  
get their address.  
NOTE!  
A complete connection diagram of the Wiegand interface is  
shown in Figure 7.7.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
Installing | en 41  
5.11  
Connecting Relay Outputs  
To operate locks or alarm systems the AMC2 4W has eight form  
C relay outputs. The outputs will be connected to the 3-pin  
pluggable screw connectors: S5, S6, S10, S11, S17, S18, S22,  
and S23 - see Figure 7.5.  
Fig. 5.18 Location of the relay output connectors  
Each relay output can operate in ‘wet’ mode, using the  
AMC2 4W's internal 12V DC power supply for external devices  
or ‘dry’ mode with potential free contacts for externally pow-  
ered systems.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
42 en | Installing  
AMC2 4W  
Fig. 5.19 Wet mode and dry mode of the AMC2 4W relay outputs  
WARNING!  
Keep in mind the following specifications.  
!
For the protection of damage the relay keep in mind, that ...  
the maximum switching current is 1,25A  
the maximum switching voltage is 30V DC  
ohm resistive load can be connected to the relay, only  
inductive loads have to be short circuited using recovery  
diodes - see: Figure 5.20. These diodes (BAX12A) are sup-  
plied with every AMC2 4W package.  
If you need higher voltage for special constructions you  
can connect external relays to the outputs. Recommended,  
depending on the power supply mode, are the relay types  
of the company Wieland:  
Flare move 12DC1W10A  
Flare move 24DC1W16A  
But you can also use products of manufacturer in your  
country - take care that the values of the product are iden-  
tical with the products listened above.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
Installing | en 43  
Fig. 5.20 Schema of the using of the recovery diode  
Risk of Damage!  
Do not connect externally powered devices in wet mode. This  
can damage the AMC2 4W.  
!
NOTE!  
A complete connection diagram of the relay output connectors  
is shown in Figure 7.9.  
Each relay output has a separate jumper setting on the bottom  
side of the lower circuit board to activate wet (D2)or dry (D1)  
mode.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
44 en | Installing  
AMC2 4W  
Fig. 5.21 Location of relay output jumpers (bottom side)  
5.12  
Connecting Analog Input Devices  
The AMC2 4W has eight analog inputs, for example, for poten-  
tial free lock mechanisms or to detect if a lock is closed or  
open. The inputs will be connected to the 2-pin pluggable  
screw connectors: S3, S4, S8, S9, S15, S16, S20, and S21 - see  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Installing | en 45  
Fig. 5.22 Location of the analog input connectors  
The AMC2 4W can also detect the wiring conditions ‘short cir-  
cuit’ and ‘broken’ and initiate an alarm if the appropriate  
devices are connected.  
1. Door open:R + R  
S
P
2. Door closed:R  
S
3. Broken wire:R + R =  
S
P
4. Short circuit:R + R = 0  
S
P
The resistor values can vary and  
depend on the used lock system  
(wire resistance negligible).  
The AMC2 4W package includes  
2,2 kresistors using for reserves  
for the R and the R resistor.  
S
P
Fig. 5.23 Operating modes of a lock  
using the analog input device  
NOTE!  
A complete connection diagram of the analog input devices is  
shown in Figure 7.8.  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46 en | Installing  
AMC2 4W  
To detect the four states there are only special values allowed  
for potential drop depending on the used resistors. The follow-  
ing table shows the values for the possible resistor combina-  
tions.  
R
1k  
1k2 1k5 2k2 2k7 3k3 3k9 4k7 5k6 6k8 8k2  
P
R
S
1k  
0,21 0,23 0,26 0,32  
1k2  
1k5  
1k8  
2k2  
2k7  
3k3  
3k9  
4k7  
5k6  
6k8  
8k2  
0,20 0,23 0,26 0,32 0,35  
0,20 0,23 0,25 0,32 0,35 0,39 0,41  
0,19 0,21 0,24 0,31 0,34 0,38 0,41 0,44 0,47 0,50  
0,20 0,23 0,30 0,33 0,37 0,40 0,43 0,47 0,50 0,53  
0,18 0,21 0,27 0,31 0,35 0,38 0,41 0,45 0,49 0,51  
0,19 0,24 0,28 0,32 0,35 0,39 0,42 0,46 0,50  
0,23 0,26 0,29 0,32 0,36 0,40 0,43 0,47  
0,20 0,23 0,26 0,29 0,32 0,35 0,39 0,42  
0,20 0,23 0,25 0,29 0,32 0,35 0,39  
0,19 0,22 0,24 0,27 0,31 0,33  
0,18 0,21 0,23 0,26 0,29  
Table 5.3 Maximum values of potential drop for the combination of resistors  
NOTE!  
It is recommended to choose the serial resistor (R ) not higher  
S
than 5K6 to get clearly values.  
5.13  
Tamper Protection  
To protect the AMC2 4W against unauthorized access and pre-  
vent the AMC2 4W from tampering with sensitive data, the  
AMC2 4W offers an additional interface to connect external  
tamper contacts. This interface is a potential-free 2-pin plugga-  
ble screw connector marked with T. If not using the tamper  
contact, short-circuit the contacts with a wire connection.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Installing | en 47  
Fig. 5.24 Location of the tamper protection contact  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
48 en | Operating  
AMC2 4W  
6
Operating  
6.1  
Status Display of the AMC2 4W  
The LC Display delivers information about the AMC2 4W status.  
Push the 'Dialog' button to switch between different modes.  
Fig. 6.1 Location of the ’Dialog’ button  
The display mode which has been set remains until the next  
operation of the ‘Dialog’ button. The order of the display pages  
is determined and follows the scheme shown in the table  
below.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
AMC2 4W  
Operating | en 49  
Push  
Display (Example)  
Description  
0
V37.02 02.03.06  
Software versions and date of  
the downloader - every 5 sec.  
alternating with the display of  
the reader interface.  
or  
WIEGAND  
(= default page)  
1
99999876543210 A BOSCH serial number and bus  
address:  
A = address 1  
...  
H = address 8  
2
3
02.06 15:35:15  
Dig. IO: :::::::::::::::: Display of the digital contacts:  
Current date and time  
setted input signals will be  
shown with an extension above -  
output signal with an extension  
below  
3a  
3b  
3c  
Dig. I1: :::::::::::::::: If there are I/O-Boards con-  
Dig. I2: ::::::::::::::::  
Dig. I3: ::::::::::::::::  
nected the signals will be shown  
on separate pages.  
4
5
6
7
8
MAC 0010174C8A0C MAC-address  
N AMC-1234-5678 Network name of the AMC  
I 192.168.10.18  
H 192.168.10.10  
DHCP 1  
IP-address of the AMC  
IP-address of the host computer  
DHCP-status:  
1 = on  
0 = off  
IP-address of the DNS server  
Host activity:  
9
10  
D 192.168.10.1  
Host: + "C"  
+ = online  
- = offline  
"C" = Counter of the received  
data packages from the host  
interface  
Tabelle 6.1 Display pages  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
50 en | Operating  
AMC2 4W  
6.2  
Configuring the Ethernet Interface  
To configure the AMC2 4W in a TCP/IP network environment  
use the tool AmcIpConfig provided in the following directory  
on the standalone or the remote server:  
\\Runtime-drive:\MgtS\AccessEngine\AC\bin  
This tool can be copied and used on every computer.  
NOTE!  
The usage of the software application to configure the  
AMC2 4W via Ethernet interface is described in the online help  
of the tool.  
6.3  
Resetting the AMC2 4W  
When a problem occurs, first, try to fix the problem directly. If  
this does not solve the problem, resetting the AMC2 4W may  
help.  
6.3.1  
Resetting the Software  
1. Insert the provided screwdriver into the hole as shown in  
the figure below.  
2. Push the reset button for at least three seconds.  
3. The AMC2 4W will be reset and reboots. You are back in  
the download program.  
Now it is possible to reconfigure the AMC2 4W from the begin-  
ning.  
If the problem still arises, please, call your local service.  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
AMC2 4W  
Operating | en 51  
Fig. 6.2 Restarting the AMC2 4W with the provided screw driver  
6.3.2  
Resetting the Network Configurations  
1. Reset the AMC2 4W as described above (in download pro-  
gram).  
2. Open the upper case of the AMC2 4W as described in  
3. Set all six DIL switches of the RS-485 selector to ON  
4. Press the tamper switch on the upper left side of the board  
The AMC2 4W will now have the following network configura-  
tion:  
DHCP = 0  
IP = 127.0.0.1  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
52 en | Operating  
AMC2 4W  
Fig. 6.3 Resetting the AMC2 4W to delivery state  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC2 4W  
7
Appendix | en 53  
Appendix  
7.1  
Connecting Diagrams  
Fig. 7.1 Connectors on upper PCB  
Fig. 7.2 RS-485 host on upper PCB  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
54 en | Appendix  
AMC2 4W  
Fig. 7.3 Connecting diagram of the RS-232 serial interface  
Fig. 7.4 Ethernet Network socket (RJ45)  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AMC2 4W  
Appendix | en 55  
Fig. 7.5 Connector blocks of the AMC2 4W  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
56 en | Appendix  
AMC2 4W  
Fig. 7.6 Power supply  
Fig. 7.7 Wiegand interface  
Fig. 7.8 Analog input  
Fig. 7.9 Relay output  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
AMC2 4W  
Appendix | en 57  
Fig. 7.10 Extension interface  
Fig. 7.11 External tamper contact  
7.2  
Legend  
Twisted pair connection  
Transmitter  
Receiver  
Bosch Security Systems  
Installation manual  
F.01U.024.965 | V.4 | 2006.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
58 en | Index  
AMC2 4W  
8
Index  
A
Address Selector 34  
Analog Input Devices 44  
Appendix 53  
face 50  
C
D
Cabling 25  
Conductor data 25  
Configuring the Ethernet Inter-  
Connecting Diagrams 53  
Demounting the AMC-4 23  
Description of the AMC-4 13  
DIL Switch 34  
E
G
I
Equipment Configuration 15  
Grounding 25  
Ethernet Interface 37  
Installing the AMC-4 22  
Legend 57  
Internet 7  
L
O
P
Opening the AMC-4 Case 24  
Operating the AMC-4 48  
Power Supply 28  
Performance Characteristics  
R
Relay Outputs 41  
RS485 Four Wire Connection  
Resetting the AMC-4 50  
RS232 Host Interface 36  
RS485 Extension Module Bus  
RS485 Host Interface 30, 31  
RS485 Two Wire Connection  
S
Safety Notes 11  
Shielding 25  
Status Display 48  
System Overview 19  
U
Used Symbols 7  
W
Wiegand Interface 39  
F.01U.024.965 | V.4 | 2006.09  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Security Systems  
Robert-Koch-Straße 100  
D-85521 Ottobrunn  
Germany  
Telefon  
Fax  
089 6290-0  
089 6290-1020  
© Bosch Security Systems, 2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Printer P74393UK User Manual
Belkin Switch PM00507 User Manual
Black Box Computer Accessories 26658 User Manual
Black Box Surge Protector 26761 User Manual
Black Box Switch Black Box SFP Managed Switch Eco User Manual
Brother All in One Printer 1575MC User Manual
Califone DJ Equipment MB 350 User Manual
Califone Headphones 2924AVPV User Manual
Campbell Hausfeld Nail Gun CHN70900 User Manual
Cary Audio Design Stereo Amplifier CAA 1 User Manual