LTC 2210 Series | Instruction Manual | FCC Information
EN 3
WARNING:
For Indoor Product
Electrostatic-sensitive device. Use
proper CMOS/MOSFET handling
precautions to avoid electrostatic
discharge.
1. Water and Moisture - Do not use this unit near
water - for example, in a wet basement, in an
unprotected outdoor installation or in any area
classified as a wet location.
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC SENSITIVE
DEVICES
2. Object and Liquid Entry - Never push objects of
any kind into this unit through openings, as they
may touch dangerous voltage points or short out
parts that could result in a fire or electrical shock.
Never spill liquid of any kind on the unit.
3. Power Cord and Power Cord Protection - For
units intended to operate with 230VAC, 50Hz,
the input and output power cord must comply
with the latest versions of IEC Publication 227 or
IEC Publication 245.
NOTE: Grounded wrist straps must be worn and proper ESD
safety precautions observed when handling the electrostatic-
sensitive printed circuit boards.
FCC & ICES INFORMATION
(U.S.A. and Canadian Models Only)
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1)
(2)
This device may not cause harmful interference, and
This device must accept any interference received,
including interference that may cause undesired
operation.
Power supply cords should be routed so they are
not likely to be walked on or pinched. Pay
particular attention to location of cords and plugs,
convenience receptacles, and the point of exit
from the appliance.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules and ICES-003 of Industry Canada. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
4. Overloading - Do not overload outlets and
extension cords; this can result in a risk of fire or
electrical shock.
For Outdoor Product
Power Lines - An outdoor system should not be
located in the vicinity of overhead power lines,
electric lights or power circuits, or where it may
contact such power lines or circuits. When
installing an outdoor system, extreme care should
be taken to keep from touching power lines or
circuits, as this contact might be fatal. U.S.A.
models only - refer to the National Electrical
Code Article 820 regarding installation of CATV
systems.
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer, or an experienced radio/TV technician for
help.
Intentional or unintentional changes or modifications, not
expressly approved by the party responsible for compliance, shall
not be made. Any such changes or modifications could void the
user’s authority to operate the equipment.The user may find the
following booklet, prepared by the Federal Communications
Commission, helpful: How to Identify and Resolve Radio-TV
Interference Problems. This booklet is available from the U.S.
Government Printing Office, Washington, DC 20402,
Stock No. 004-000-00345-4.
For Rack-mount Product
1. Ventilation - This unit should not be placed in a
built-in installation or rack, unless proper
ventilation is provided, or the manufacturer’s
instructions have been adhered to. The
equipment must not exceed its maximum
operating temperature requirements.
2. Mechanical Loading - Mounting of the
equipment in a rack shall be such that a
hazardous condition is not achieved due to
uneven mechanical loading.
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Safety Precautions
EN 4
Safety Precautions
Sécurité
ATTENTION : POUR ÉVITER TOUT RISQUE D'ÉLECTROCUTION,
N'ESSAYEZ PAS DE RETIRER LE CAPOT (OU LE PANNEAU
ARRIÈRE). CET APPAREIL NE CONTIENT AUCUN COMPOSANT
SUSCEPTIBLE D'ÊTRE RÉPARÉ PAR L'UTILISATEUR. CONFIEZ
LA RÉPARATION DE L'APPAREIL À DU PERSONNEL QUALIFIÉ.
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Ce symbole signale que le produit renferme une « tension
potentiellement dangereuse » non isolée susceptible de
provoquer une électrocution.
This symbol indicates the presence of
uninsulated “dangerous voltage” within the
product’s enclosure that can cause an electric
shock.
Ce symbole invite l'utilisateur à consulter les instructions
d'utilisation et d'entretien (dépannage) reprises dans la
documentation qui accompagne l'appareil.
This symbol indicates the presence of
important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.
Attention : l'installation doit exclusivement être réalisée par du
personnel qualifié, conformément au code national d'électricité
américain (NEC) ou au code d'électricité local en vigueur.
Coupure de l'alimentation. Qu'ils soient pourvus ou non d'un
commutateur ON/OFF, tous les appareils reçoivent de l'énergie une
fois le cordon branché sur la source d'alimentation. Toutefois,
l'appareil ne fonctionne réellement que lorsque
le commutateur est réglé sur ON. Le débranchement du cordon
d'alimentation permet de couper l'alimentation des appareils.
Installation should be performed by qualified
service personnel only in accordance with the
National Electrical Code or applicable local
codes.
Power Disconnect. Units with or without
ON-OFF switches have power supplied to the
unit whenever the power cord is inserted into the
power source; however, the unit is operational
only when the ON-OFF switch is in the ON
position. The power cord is the main power
disconnect for all units.
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Contents
EN 5
Table of Contents
Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.0
1.1
2.0
3.0
4.0
4.1
4.3
4.4
4.5
4.6
5.0
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Video Looping Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Alarm/Accessory Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Programming System Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Key Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Alarm Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Zone Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Defining a Zone for Motion Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Adding a Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Editing, Moving or Deleting a Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Detection Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Percentage Movement For Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
System Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.10 Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.11 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.12 Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.13 Operation and Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
6.0
ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Unpacking
EN 6
1.0 UNPACKING
3.0 DESCRIPTION
This equipment should be unpacked and handled with
care. If an item appears to have been damaged in
shipment, notify the shipper.
The LTC 2210 Series video motion detectors utilize
edge detection with digital tracing technology. Patented
circuitry provides reliable security surveillance
protection. These economical, full featured single
channel detectors provide flexible operation to
maximize performance and minimize false alarms.
Verify that all parts shown in the Parts List have been
included. If any items are missing, notify your Bosch
Security Systems Sales or Customer Service
Representative.
Motion is detected over the full active video for NTSC,
PAL and SECAM.
The original packing carton is the safest container in
which to transport the unit. Save it for possible future
use.
4.0 INSTALLATION
4.1 Power
Model
1.1 Parts List
LTC2210/60
LTC 2210/50
Qty Item
Rated Voltage
Voltage Range
120 VAC, 50/60 Hz 230 VAC, 50/60 Hz
1
1
Unit (verify model number)
105 to 130
195.5 to 253
5 W
One (1) 15-pin cable assembly
Power at rated voltage
5 W
2.0 SERVICE
If the unit needs repair, contact the nearest Bosch
Security Systems Service Center for authorization to
return and shipping instructions.
4.2 Mounting
These motion detectors are supplied as desk top half-
rack units. For rack mounting, the LTC 9101/00 rack-
mount kit is available.
Service Centers
USA
Phone:
Fax:
CCTV Spare Parts
800-366-2283 or 717-735-6638
800-366-1329 or 717-735-6639
4.3 Video Looping Input
There are two smart BNC connectors on the rear
panel named IN and LOOP. The camera input should
be connected to IN while LOOP may be used as a
looping output. The camera input is automatically
terminated (nonlooping operation) or unterminated
(looping operation).
Phone:
Fax:
E-mail:
800-894-5215 or 408-956-3853 or 3854
408-957-3198
Canada
Phone:
514-738-2434
Europe, Middle East & Asia Pacific Region
Phone: 32-1-440-0711
For additional information, see
4.4 Monitor Output
The monitor output, named OUT, is designed for a
75 Ω load. Therefore if the monitor output cable is
looped through other accessories, ensure that the last
unit on the line has its termination set to 75 Ω
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Operatio
EN 7
The first line of each menu gives the menu name. The
main menu is the first menu displayed. In addition to
the menu name the first line of this menu also displays
the version number of the software in this product. All
programmable items are given in the lines immediately
below the menu name. The last two lines provide help
information.
4.5 Alarm/Accessory Connector
A cable with a connector is supplied connecting to
alarm closures or other accessories.
The alarm output creates a short between the two
output pins (pins 9 and 14 Alarm Relay (NO)) when an
alarm occurs and open-circuits the pins when no
alarms are active (triggered). The alarm output has a
maximum carrying current of 1 A and a maximum
switching voltage of 40 V AC/DC. The alarm output
can be used to signal a VCR, lamp or relay.
5.0 OPERATION
5.1 Key Operations
MENU SCROLL: The ↑ or ↓ arrow keys are used to
scroll through menu items. The > character indicates
the currently selected menu item. The ↑ or ↓ arrow
keys are also used to program zone size and
placement.
The Alarm 1 (pin 6) is an open-collector output. It is
switched to ground when an alarm occurs (maximum
rating: 15 V, 30 mA).
The Remote Alarm Enable Input (pin 15) allows some
other security device, such as an access control system,
to enable the motion detector. The motion detector is
enabled when the Remote Alarm Enable Input is
switched to ground (<1 volt) and the Alarm Enable
option on the Main Menu is set to REMOTE. The
ENTER: Pressing the ENTER key scrolls through the
options at current selected menu item.
CHANGE CURSOR POSITION: The ← or → arrow
Remote Alarm Enable Input is disabled when the input keys are used to position zones and to program alarm
is not connected or the applied input voltage is greater
that 1 volt. The maximum input voltage that can be
applied is 15 volts.
capture times.
EXITING A MENU: The ESC key or Previous Menu
option is used to exit to a previous menu. If the top
level menu is being displayed, pressing the ESC key or
selecting the Exit Menu option will exit from
Programming.
Belden 8760 twisted shielded cable (or
equivalent) should be used for wiring to the
alarm connector and the total length of
unshielded cable should not exceed 10 cm
(3.9 in.) on each connector port to maintain
compliance with Directive 89/336/EEC.
The Main Menu contains 5 settings. All of these
settings access sub-menus except for ALARM
ENABLE and LANGUAGE. If no key is pressed for a
period of 15 minutes, the menus will be automatically
exited.
4.6 Programming System Setup
Configuration options are provided through on-screen
menus. These menus are accessed by using the SETUP
key. With video present on the monitor, a momentary
press and release of the SETUP key will gain easy
access to the Main Programming Menu.
5.2 Alarm Enable
This option is used to switch on the motion detector.
When Alarm Enable is ON, the product will detect
motion in the active zones defined for motion
detection (see Zone Setup). If motion is detected, all
alarm outputs will be switched on. When Alarm
Enable is set to REMOTE, the unit will detect motion
when the external remote alarm input is active (pin 15
of the Alarm Accessory Connector). The input is active
when it is switched to Ground.
MAIN MENU VER 1.01
EXIT MENUS
ALARM ENABLE
ZONE SETUP
SYSTEM SETUP
DISPLAY
ON
LANGUAGE
ENGLISH
ENTER
↓
Select:
Exit Menu:ESC Scroll:
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Operation
EN 8
A single line of help is displayed by default at the
5.3 Zone Setup
bottom of the screen. Zones can also be created over
this area. If this hinders defining the zone area, the
help information can be removed from the screen by
pressing the arrow â, ß keys simultaneously. Pressing
these keys again will display the help information once
more.
This menu is used to define the areas where motion
can be detected. A total of 8 different zones can be
defined. Unrestricted areas where motion is permitted
and other unnecessary areas should not be included in
the active zones. This will eliminate alarms caused by
motion in areas which are not considered important for
security purposes.
5.5 Adding a Zone
To add a Zone, select Add ZONE from the Define
Zone menu. A cursor will be displayed on the monitor
screen as a small translucent block. Position the cursor
where you wish the top left hand corner of the zone to
start, and press the ENTER key. This defines a
minimum size zone. The zone size increases and
decreases as the arrow keys are moved. When the
Zone is the desired size and shape; press the ENTER
key again to complete the creation of the Zone. The
minimum zone area will be approximately 15%
horizontal & 15% vertical of the full screen.
ZONE SETUP
> PREVIOUS MENU
DEFINE ZONES
SENSITIVITY
MOVEMENT
3
2
Select:
Prev Menu:ESC Scroll:
ENTER
↓
5.6 Editing, Moving or Deleting a Zone
These options are selected to change the shape,
position or remove a zone. Select EDIT, MOVE or
DELETE ZONE options from the Define Zone menu.
All created zones are displayed on the screen. The
arrow á or â keys are used to select the zone to be
edited. The presently selected Zone will flash. The
ENTER key is pressed to confirm the Zone selection.
5.4 Defining a Zone for Motion Detection
Select the DEFINE ZONES menu.
DEFINE ZONES
> PREVIOUS MENU
ADD ZONES
For EDIT or MOVE options, the arrow keys can be
used to resize or reposition the zone.
EDIT ZONES
MOVE ZONES
For DELETE Zone; a confirmation message is
displayed on the screen.
DELETE ZONE
Delete Zone:
NO
DELETE ALL ZONES
↑
Select:
ENTER
Scroll:
↓↑
Prev Menu:ESC Scroll:
↓
Select:
ENTER
ESC
Previous Menu:
Menu options are available to ADD (create a new
zone) move, edit (re-create a zone) and delete zones.
This option must be changed to YES to delete the
zone. The Delete All Zones options allows all zones to
be removed by one command.
Zones are displayed as a solid rectangular translucent
box. Multiple zones can be defined and placed
adjacent to or overlapping each other to create more
complex shapes.
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Operation
EN 9
This menu defines parameters specific to the operation
on the motion detector.
5.7 Detection Sensitivity
This option is programmed from the Zone Setup
menu. It defines the difference in luminance between
an object and its background which is required to
produce an alarm. The following chart may be used as
a guide to arrive at the correct setting:
Item
Settings
Description
Beeper
ON/OFF
If ON, the beeper will
sound when motion is
detected.
AlarmReset
MANUAL/AUTO
AUTO: Upon alarm, the
alarm beeper, LED and
relay will reset
Sensitivity
Setting
Description
1
2
3
4
Low (High noise/high contrast images)
Medium Low
automatically after a
predetermined interval in
alarm, as determined by
the alarm dwell time.
MANUAL: The ALM CLR
button on the front panel
must be pressed to reset
the alarm.
Medium High
High (Low noise/low contrast)
NOTE: A Sensitivity Setting of 3 (Medium High) will
work well for most installations.
Motion Tracer ON/OFF
If ON, the user can see
where, in the active area,
motion has been
5.8 Percentage Movement For Detection
This option is programmed from the Zone Setup
menu. It defines the percentage of total screen width or
height that the target must cross before the LTC 2210
Series will generate an alarm signal. The following
chart may be used as a guide to arrive at the correct
setting:
detected. This is useful for
optimizing the Percentage
Movement and Sensitivity
settings.
AlarmDwell
4 .. 60
Sets the alarm relay and
beeper on duration when
in alarm from a minimum
of 4 seconds, to a
Movement
Setting
Description
maximum of 60
1
2
3
5% (Slow moving objects/wide field of view)
10% (Normal movement/normal field of view)
seconds.Use ßà arrow
keys to step through
times.
15% (Fast moving objects/narrow field of
view)
5.10 Factory Defaults
NOTE: A movement setting of 2 (10% Normal
movement/normal field of view) will work well for
most installations.
This option returns the LTC 2210 to factory default
settings.
For system operation, these are:
5.9 System Setup
ALARM ENABLE
SENSITIVITY
MOVEMENT
ON
03
SYSTEM
02
> PREVIOUS MENU
BEEPER
OFF
OFF
AUTO
14
BEEPER
OFF
OFF
AUTO
14
MOTION TRACER
ALARM RESET
ALARM DWELL
LANGUAGE
MOTION TRACER
ALARM RESET
ALARM DWELL
FACTORY DEFAULTS
ENGLISH
For the display menu, these are:
DISPLAY ZONE
BACKGROUND
ALL ACTIVITY
OVERSCAN
OFF
Select:
Prev Menu:ESC Scroll:
ENTER
OUTLINED
OFF
↓
05
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Operation
EN 10
1. The LTC 2210 can detect motion over the full active
video signal, however all of this cannot be displayed
on the video monitor as most video monitors cannot
display the entire active video signal. This parameter
allows the video area where detection zones are
defined to be restricted so that the full detection area
can always be seen on the display monitor.
5.11 Display
The display menu is used to configure how the motion
detector looks on the monitor screen.
Display
>PREVIOUS MENU
DISPLAY ZONE
BACKGROUND
ALL ACTIVITY
OVERSCAN
OFF
Changing the OVERSCAN setting reduces the
video area where zones are drawn.
OUTLINED
OFF
2. An Overscan Setting of 05 (5%) will display the
complete detection area on most video monitors.
05
5.12 Language
Use the Language option on the main menu to change
the language. Press ENTER to select the required
language. All screens will now be displayed in the
selected language.
Select:
ENTER
Exit Menu:ESC Scroll:
↓
Item
Settings
Description
DisplayZone
ON/OFF
Switching this option on
displays the defined active
zones during operation.
This is useful when
The options are: English, French, German, Spanish,
Dutch, and Italian.
5.13 Operation and Setup
programming and adjusting
the motion detector.
Most programmable options are set to values that
should work without change for most applications. It is
normally only necessary to define the area where
motion should be detected. To do this press the
SETUP key to enter the programming. Select Zone
Setup followed by Define Zone. Define a Zone where
you wish to detect motion. Press ESC several times to
leave programming.
Background
OUTLINED/
SOLID
This allows the menu
background to be changed
from a solid black
background to a
transparent background,
where the menu text is
fringed.
ALL
ACTIVITY
ON/OFF
Switching this option ON
displays Motion Tracer dots
on the monitor screen for
all movement, even if it is
not sufficient to be
detected as motion.
OVERSCAN
00
052
10
Full Video, no reduction
Reduces video by 5%
Reduces video by 10%
Reduces video by 20%
20
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Illustrations
EN 11
6.0 ILLUSTRATIONS
Figure 1 Front and Back Panels
Pin
1
Function
Ground
NC
Pin
9
Function
Alarm Relay (NO)
2
10
11
12
13
14
NC
1
2
3
4
5
6 11
3
NC
NC
12
13
14
15
7
8
4
NC
NC
5
NC
NC
6
Alarm 1
NC
Alarm Relay (NO)
Remote Alarm Enable
9
7
15
Input
10
8
NC
NOTE: NC designates No Connection, NO designates Normally Open.
Figure 2 ALARM/ACCESSORY Connector
Bosch Security Systems | December 17, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
|
LTC 2210 Series | Instruction Manual | Illustrations
EN 12
Camera #3
Video
Door Actuation Switch
Camera #2
Smoke Detector
Camera #4
Camera #1
Motion Detector
ALARM/
ACCESSORY
1
2
3
4
5
6
7
8
9
11
12
13
14
10 15
Additional Cameras
75
1
75
75
3
W
W
W
Hi-Z
ALARM/
ACCESSORY
MON
A
CAM
C
AM
CAM
2
4
5
6
7
8
MON
B
Switcher
To Terminated
Auxiliary Monitor
or Terminated Switcher
Alarm Output
Relay Closu re
75
W
75
W
Figure 3 Typical Installation
Bosch Security Systems, Inc.
850 Greenfield Road
Bosch Security Systems B.V.
P.O. Box 80002
Bosch Security Systems Pte Ltd.
38C Jalan Pemimpin
Lancaster, PA 17601 USA
Tel: 800-326-3270
Fax: 1-717-735-6560
5600 JB Eindhoven
The Netherlands
Tele +31 40 27 87113
Singapore 577180
Republic of Singapore
Tel: 65 (6) 319 3486
© 2004 Bosch Security Systems GmbH
3935 890 05782 51-04 | Updated December 17, 2004 | Data subject to change without notice.