		 Plastic Fiber Optic Assembly model PBT26U   
					.02" diameter bifurcated fiber with threaded sensing end   
					PBT26U   
					p/n 26080   
					Description   
					Model PBT26U is a bifurcated plastic fiber optic assembly with an   
					M3 x 0,5mm threaded nickel plated brass sensing end.   
					Threaded sensing end   
					The PBT26U operates in the diffuse sensing mode. Sensing light is   
					transmitted and received through the threaded sensing end. Objects   
					are detected by the light they reflect back through the sensing end.   
					Fiber core diameter is .02 inch.   
					The PBT26U may be used with plastic fiber optic sensors from the   
					following Banner sensor families: D12, OMNI-BEAM, MAXI-BEAM, VALU-BEAM, Q45, MINI-BEAM, and   
					ECONO-BEAM. See page 2 for further information.   
					Additional Specifications   
					SENSING RANGE: Afunction of the sensor. For further information, see the   
					CHEMICAL RESISTANCE: The acrylic core of the monofilament opti-   
					cal fiber will be damaged by contact with acids, strong bases (alkalis) and   
					solvents. The polyethylene jacket will protect the fiber from most chemical   
					environments. However, materials may migrate through the jacket with long   
					term exposure. Samples of fiber optic material are available from Banner for   
					testing and evaluation.   
					data sheet packed with the sensor, or refer to the Banner product catalog.   
					TEMPERATURE EXTREMES: Temperatures below -30°C will cause   
					embrittlement of the plastic materials but will not cause transmission loss.   
					Temperatures above +70°C will cause both transmission loss and fiber   
					shrinkage.   
					MINIMUM BEND RADIUS OF PLASTIC FIBER: 0.5 inch (12 mm)   
					REPEATBENDING/FLEXING: Lifeexpectancyofplasticfiberopticcable   
					is in excess of one million cycles at bend radii of no less than the minimum   
					(stated at right) and a bend of 90 degrees or less. Avoid stress at the point where   
					the cable enters the sensor ("control end") and at the sensing end tip. Coiled   
					plastic fiberoptic assemblies are recommended for any application requiring   
					reciprocating fiber motion.   
					CONSTRUCTION:   
					OPTICAL FIBER: acrylic monofilament   
					PROTECTIVE JACKET: black polyethylene   
					THREADED END TIP and hardware: nickel plated brass   
					OPERATING TEMPERATURE: -30 to +70°C (-20 to +158°F).   
					Fiber Cutting Information   
					This Banner plastic fiber is designed to be cut by the customer to the length required for the appli-   
					cation. To facilitate cutting, a Banner model PFC-1 cutting device is supplied with this fiber.   
					Cut the fiber as follows:   
					PFC-1 Cutting Device   
					1) Locate the "control end" of the fiber (the unfinished end). Determine the length   
					of fiber required for the application. At the control end of the fiber, separate the two   
					fibers. Lift the top (blade) of the cutter to open the cutting ports. Insert one of the   
					control ends through one of the two small cutting ports on the PFC-1 cutter so that the   
					excess fiber protrudes from the back of the cutter.   
					2) Double-check the fiber length, and close the cutter until the fiber is cut. Using a differ 
					cutting port, cut the second control end to the same length as the first.   
					3) Gently wipe the cut ends of the fiber with a clean, dry cloth to remove any contamination.   
					Do not use solvents or abrasives on any exposed optical fiber. Do not use a cutting port more than once. The blade   
					may tend to dull after one cut.   
					Printed in USA   
					p/n 03431L4B   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |