To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
Roughing-in
8 TO 12
FINISHED
WALL
TRANSFER VALVE
Dimensions
(FOR FLUSHING
RIM OR SPRAY)
BIDET OUTLINE
IS SYMBOLIC
2-1/4
DIA.
Plumbers' Putty or
Caulking
Screwdriver
(C)
(H)
7/8 DIA.
1-3/16
DIA.
DOUCHE
SPRAY
2-1/8
DIA.
4-1/4
ADJ. 1-1/4
TO 2-1/4
1-1/4
MAX.
Phillips Screwdriver
Channel Locks
Tubing Cutter
1-3/8
DIA.
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
3-7/8
REAR VIEW WITH
WALL REMOVED
FINISHED
FLOOR
Adjustable Wrench
5-1/2
1-1/4 O.D. TAILPIECE
Turn off hot and cold water
supplies before beginning.
BIDET FAUCET INSTALLATION CAUTION
1
2
6
7
Place RUBBER RING (10) into ESCUTCHEON (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
4
BIDET
LEDGE
10
8
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
4
10
Fig. A.
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
3a
5/16''
MIN.
MOUNTING
SURFACE
3
COLD
2
1
HOT
9
2
1
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
11
5
3, 3a
2
8
7
9
1
SPRAY INSTALLATION
PUTTY
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
6
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).
1
Download from Www.Somanuals.com. All Manuals Search And Download.
ATTACH CABLE
CONNECTOR
8
9
Fig. A.
Fig. B.
Fig. C.
DOWN
POP-UP KNOB (1) must be fully
down. Fig. A.
1
Thread CABLE CONNECTOR (1)
clockwise onto DRAIN BODY
CONNECTION (2) and hand
tighten. Fig. B.
Your new POP-UP DRAIN
installation is now complete.
Fig. C.
2
1-1/4” O.D.
Note: Tailpeice on pop-up drain
is 1-1/4” O.D. Fig. C.
CHECK OPERATION OF POP-UP
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)
opens and closes.
1
3
1
Note: If STOPPER (2) does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
2
INSTALL DIVERTER KNOB
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should
point downwards.
OUTLINE OF BIDET
TEE AND HOSE CONNECTION
10
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to
side of TRANSFER VALVE (3).
5
6
6
3
Install SEAL (4) into coupling nut of TEE (5) and tighten
connection to ADAPTER (2).
7a
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve
bodies and securely tighten.
COUPLING
NUT
4
2
1
Front
9
7
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
WATER SUPPLY CONNECTION
COMPRESSION
NUT
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
2
FLEXIBLE
SUPPLIES
Connect water supply to VALVE BODIES (7,7a) with
FERRULE
1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE
RISERS (9). Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
COLD
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
CONNECT TO
WASTE OUTLET
3/8 COMPRESSION
CONNECTION
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
HOT
M968677 Rev. 1.1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL HANDLES
4
11
LEVER HANDLE
Turn HANDLE STEM (1) to "OFF" position.
Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the
ADAPTER SCREW (3) and tighten securely.
5
Position LEVER HANDLE (4) and place on ADAPTER (2). Install the
HANDLE SCREW (5) and tighten securely.
3
2
1
TEST INSTALLED FITTING
OUTLINE OF BIDET
1
12
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
3
Operate both HANDLES (1) to flush water
lines thoroughly.
1
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
CHECK DRAIN CONNECTIONS
13
Pull up POP-UP KNOB (3) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
4
2
please refer to “Troubleshooting Guide” in these instructions.
SPRAY
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
2
SERVICE
CARE INSTRUCTIONS:
To change direction of handle
rotation, proceed as follows:
14
15
1
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER. DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
2
Pull HANDLE (2) off ADAPTER (4). Loosen ADAPTER
3
4
SCREW (3) and pull off ADAPTER (4).
Remove SPRING CLIP (7). Lift STOP WASHER (5),
turn 90° and replace. Replace SPRING CLIP (7).
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
90˚
5
6
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
7
M968677 Rev. 1.1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
Fig. A.
Fig. B. Fig. C.
CAM
1
1
RE-ATTACH
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
REMOVE
CAM CAP
M968677 Rev. 1.1
Download from Www.Somanuals.com. All Manuals Search And Download.
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
LOGO
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
LOGO
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
180˚
LOOP TOWARD
FRONT OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968677 Rev. 1.1
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Installation
Instructions
3475.301
COLONY/COLONY SOFT
Bidet Faucet and Transfer Valve
3475.501
with SpeedConnect™ Drain
Congratulations on purchasing your American
Standard faucet with Speed Connect drain, a
feature found only on American Standard faucets.
Certified to comply with ANSI A112.18.1
SpeedConnect Drain*
M968796 Rev.1.1
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
Roughing-in Dimensions
8 TO 12
DIVERTER AND
FINISHED
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
VACUUM BREAKER
ASSEMBLY
WALL
BIDET OUTLINE
IS SYMBOLIC
Plumbers' Putty or
Caulking
Screwdriver
2-1/4
DIA.
(C)
(H)
7/8 DIA.
1-3/16 DIA.
1-1/4 MAX.
DOUCHE
SPRAY
2-1/8
DIA.
ADJ. 1-1/4
TO 2-1/4
4-1/4
Phillips Screwdriver
Channel Locks
Tubing Cutter
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
1-3/8
DIA.
3-7/8
REAR VIEW WITH
WALL REMOVED
FINISHED
FLOOR
Adjustable Wrench
5-1/2
1-1/4 O.D. TAILPIECE
Turn off hot and cold water
supplies before beginning.
BIDET FAUCET INSTALLATION CAUTION
1
11
6
7
Place RUBBER RING (10) into ADAPTER (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ADAPTER (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
4
BIDET
LEDGE
10
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
4
10
MOUNTING
SURFACE
Fig. A.
to secure VALVE BODIES (3, 3a).
Remove MOUNTING NUT (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
5/16''
MIN.
3a
3
COLD
2
1
HOT
8
2
1
9
Replace UPPER GASKET (8) and WASHER (7) . Position
the side threaded outlet rearward and secure MOUNTING
NUT (6). Thread ESCUTCHEON (11) onto TRANSFER
VALVE (9) until it seats against the BIDET LEDGE.
3, 3a
5
8
2
9
1
SPRAY INSTALLATION
2
PUTTY
7
6
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).
1
Download from Www.Somanuals.com. All Manuals Search And Download.
POP-UP DRAIN
3
4
Fig. A.
Fig. B.
DRAIN
BODY
Remove CLEAR PLASTIC COVER (1).
1
3
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
7
2
REMOVE FLANGE
Fig. A.
Fig. B.
1
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
4
3
2
INSTALL DRAIN FROM
BELOW FIXTURE
TIGHTEN LOCKNUT
5
7
6
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
From under side of BIDET
install DRAIN BODY (1) up
4
through drain outlet.
3
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the BIDET.
DRAIN
OUTLET
1
2
1
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above BIDET and tighten
FLANGE (4) firmly.
FLANGE GASKET
Fig. A.
Fig. B.
1
Check DRAIN FLANGE in BIDET to ensure that WHITE
FOAM GASKET (1) is fully compressed and not visible.
Fig. A.
3
DRAIN
FLANGE
5
POP-UP ROD ASSEMBLY
SLOTTED
MOUNTING
NUT
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2)
through rear hole, making sure SEAL WASHER (3) is
properly seated. Fig. B.
4
WHITE FOAM
GASKET
NOT VISIBLE
1
ILLUSTRATION
SHOWN LESS
VALVES
2
From below slip slot in MOUNTING NUT (4) over CABLE (5).
Thread NUT (4) onto lift rod guide shank to secure ROD
GUIDE (1) to bidet. Hand tighten only. Fig. B.
M968796 Rev.1.1
2
Download from Www.Somanuals.com. All Manuals Search And Download.
ATTACH CABLE
CONNECTOR
8
9
Fig. A.
Fig. B.
Fig. C.
DOWN
POP-UP KNOB (1) must be fully
down. Fig. A.
1
Thread CABLE CONNECTOR (1)
clockwise onto DRAIN BODY
CONNECTION (2) and hand
tighten. Fig. B.
Your new POP-UP DRAIN
installation is now complete.
Fig. C.
2
1-1/4” O.D.
Note: Tailpeice on pop-up drain
is 1-1/4” O.D. Fig. C.
CHECK OPERATION OF POP-UP
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)
opens and closes.
3
1
1
Note: If STOPPER (2) does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
2
INSTALL DIVERTER KNOB
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should
point downwards.
TEE AND HOSE CONNECTION
10
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to
bottom of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut of TEE (5) and tighten
connection to ADAPTER (2).
3
7a
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve
bodies and securely tighten.
6
2
1
4
Front
5
COUPLING
NUT
WATER SUPPLY CONNECTION
6
7
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
3
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
Connect water supply to VALVE BODIES (7,7a) with
1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE
RISERS (3). Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
COMPRESSION
NUT
2
FLEXIBLE
SUPPLIES
FERRULE
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
COLD
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
CONNECT TO
WASTE OUTLET
HOT
3/8 COMPRESSION
CONNECTION
M968796 Rev.1.1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL HANDLES (Lever)
INSTALL HANDLES (Acrylic)
11
Turn HANDLE STEM (1) to "OFF"
position.
Turn HANDLE STEM (1) to "OFF"
position.
4
3
Place the ACRYLIC HANDLE (2)
on the HANDLE STEM (1).
Place the HANDLE ADAPTER (2)
on the HANDLE STEM (1).
5
4
3
Install the HANDLE SCREW (3)
and tighten securely.
Install the ADAPTER SCREW (3)
and tighten securely. Position
LEVER HANDLE (4) and place
on ADAPTER (2).
Push in INDEX BUTTON (4).
2
1
2
1
Install the HANDLE SCREW (5)
and tighten securely with hex
wrench supplied.
TEST INSTALLED FITTING
12
5
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
1
3
Operate both HANDLES (1) to flush water
lines thoroughly.
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
1
4
CHECK DRAIN CONNECTIONS
13
SPRAY
Pull up POP-UP KNOB (3) and fill Bidet with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
please refer to “Troubleshooting Guide” in these instructions.
2
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
2
SERVICE
EverClean™ Finish
Care Instructions
To change direction of handle
rotation, proceed as follows:
14
15
1
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
American Standard’s EverClean
finish will wipe clean with a soft,
dry cloth.
A soft cloth with clean water
may also be used, if desired.
No additional cleaning products
are required.
2
4
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER
SCREW (4) and pull off ADAPTER (3).
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3)
catches on the other FLAT on VALVE STEM (5).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
3
5
DO NOT USE: Soaps, acid,
polish, abrasives, harsh
cleaners, or a cloth with a
coarse surface.
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
M968796 Rev.1.1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SpeedConnect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
Fig. A.
Fig. B. Fig. C.
CAM
1
1
RE-ATTACH
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
REMOVE
CAM CAP
M968796 Rev.1.1
5
Download from Www.Somanuals.com. All Manuals Search And Download.
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
LOGO
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
LOGO
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
180˚
LOOP TOWARD
FRONT OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Unlocked Mode
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968796 Rev.1.1
6