Installation  
Instructions  
3475.500  
COLONY/COLONY SOFT  
Bidet Faucet and Transfer Valve  
with Speed Connect™ Drain  
Congratulations on purchasing your American  
Standard faucet with the Speed Connect drain, a  
feature found only on American Standard faucets.  
Certified to comply with ANSI A112.18.1  
M968677 Rev. 1.1  
Speed Connect Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
Required tools  
Roughing-in  
8 TO 12  
FINISHED  
WALL  
TRANSFER VALVE  
Dimensions  
(FOR FLUSHING  
RIM OR SPRAY)  
BIDET OUTLINE  
IS SYMBOLIC  
2-1/4  
DIA.  
Plumbers' Putty or  
Caulking  
Screwdriver  
(C)  
(H)  
7/8 DIA.  
1-3/16  
DIA.  
DOUCHE  
SPRAY  
2-1/8  
DIA.  
4-1/4  
ADJ. 1-1/4  
TO 2-1/4  
1-1/4  
MAX.  
Phillips Screwdriver  
Channel Locks  
Tubing Cutter  
1-3/8  
DIA.  
FOR GROUND JOINT  
CONNECTION OR 1/2 "  
O.D. SLIP (INLETS)  
3-7/8  
REAR VIEW WITH  
WALL REMOVED  
FINISHED  
FLOOR  
Adjustable Wrench  
5-1/2  
1-1/4 O.D. TAILPIECE  
Turn off hot and cold water  
supplies before beginning.  
BIDET FAUCET INSTALLATION CAUTION  
1
2
6
7
Place RUBBER RING (10) into ESCUTCHEON (4).  
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From  
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting  
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above  
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a)  
until snug against internal stop. If necessary, adjust LOCKNUT (1).  
4
BIDET  
LEDGE  
10  
8
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)  
to secure VALVE BODIES (3, 3a).  
4
10  
Fig. A.  
Remove ESCUTCHEON (6), WASHER (7) and  
UPPER GASKET (8) from TRANSFER VALVE (9).  
Insert TRANSFER VALVE (9) into the center forward  
hole of BIDET.  
3a  
5/16''  
MIN.  
MOUNTING  
SURFACE  
3
COLD  
2
1
HOT  
9
2
1
Replace UPPER GASKET (8) and WASHER (7) and  
ESCUTCHEON (6) until it locks against internal stop.  
Position the side threaded outlet rearward and  
secure MOUNTING NUT (11).  
11  
5
3, 3a  
2
8
7
9
1
SPRAY INSTALLATION  
PUTTY  
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside  
of SPRAY BODY FLANGE (2) and secure with NUT (3).  
6
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).  
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet  
NIPPLE (7) of the TRANSFER VALVE (8).  
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACH CABLE  
CONNECTOR  
8
9
Fig. A.  
Fig. B.  
Fig. C.  
DOWN  
POP-UP KNOB (1) must be fully  
down. Fig. A.  
1
Thread CABLE CONNECTOR (1)  
clockwise onto DRAIN BODY  
CONNECTION (2) and hand  
tighten. Fig. B.  
Your new POP-UP DRAIN  
installation is now complete.  
Fig. C.  
2
1-1/4” O.D.  
Note: Tailpeice on pop-up drain  
is 1-1/4” O.D. Fig. C.  
CHECK OPERATION OF POP-UP  
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)  
opens and closes.  
1
3
1
Note: If STOPPER (2) does not open and close properly  
then refer to the “troubleshooting section” of these  
instructions.  
2
INSTALL DIVERTER KNOB  
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).  
Push on RING (3) and tighten with SCREW (4).  
Press on KNOB CAP (5).  
Note: Screwdriver gap is for disassembling and should  
point downwards.  
OUTLINE OF BIDET  
TEE AND HOSE CONNECTION  
10  
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to  
side of TRANSFER VALVE (3).  
5
6
6
3
Install SEAL (4) into coupling nut of TEE (5) and tighten  
connection to ADAPTER (2).  
7a  
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve  
bodies and securely tighten.  
COUPLING  
NUT  
4
2
1
Front  
9
7
3/8 O.D.  
BULL-NOSE  
RISERS  
1/2" PIPE  
THREAD  
WATER SUPPLY CONNECTION  
COMPRESSION  
NUT  
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT  
INCLUDED AND MUST BE PURCHASED SEPARATELY.  
2
FLEXIBLE  
SUPPLIES  
Connect water supply to VALVE BODIES (7,7a) with  
FERRULE  
1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE  
RISERS (9). Use adjustable wrench to tighten connections.  
Do not over tighten. Be careful not to kink copper supply when  
bending. Use tubing cutter to cut to proper length.  
COLD  
Connect HOT water supply to inlet of left SHANK and COLD  
water supply to right SHANK using sealant, appropriate  
connectors, and COUPLING NUTS.  
CONNECT TO  
WASTE OUTLET  
3/8 COMPRESSION  
CONNECTION  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
HOT  
M968677 Rev. 1.1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALL HANDLES  
4
11  
LEVER HANDLE  
Turn HANDLE STEM (1) to "OFF" position.  
Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the  
ADAPTER SCREW (3) and tighten securely.  
5
Position LEVER HANDLE (4) and place on ADAPTER (2). Install the  
HANDLE SCREW (5) and tighten securely.  
3
2
1
TEST INSTALLED FITTING  
OUTLINE OF BIDET  
1
12  
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
3
Operate both HANDLES (1) to flush water  
lines thoroughly.  
1
Rotate TRANSFER VALVE (5) from rim wash to  
spray several times to check operation.  
CHECK DRAIN CONNECTIONS  
13  
Pull up POP-UP KNOB (3) and fill Sink with water. Check  
that DRAIN STOPPER (4) makes a good seal and retains  
water in Bidet. If STOPPER (4) does not seal properly,  
4
2
please refer to “Troubleshooting Guide” in these instructions.  
SPRAY  
Push POP-UP KNOB (3) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
2
SERVICE  
CARE INSTRUCTIONS:  
To change direction of handle  
rotation, proceed as follows:  
14  
15  
1
Turn VALVE to OFF position.  
Loosen HANDLE SCREW (1) .  
DO: SIMPLY RINSE THE PRODUCT  
CLEAN WITH CLEAR WATER. DRY  
WITH A SOFT COTTON FLANNEL  
CLOTH.  
2
Pull HANDLE (2) off ADAPTER (4). Loosen ADAPTER  
3
4
SCREW (3) and pull off ADAPTER (4).  
Remove SPRING CLIP (7). Lift STOP WASHER (5),  
turn 90° and replace. Replace SPRING CLIP (7).  
DO NOT: DO NOT CLEAN THE  
PRODUCT WITH SOAPS, ACID,  
POLISH, ABRASIVES, HARSH  
CLEANERS, OR A CLOTH WITH  
A COARSE SURFACE.  
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).  
Tighten HANDLE SCREW (1).  
90˚  
5
6
If spout drips, operate handles several  
times from OFF to ON position. Do not  
force - handles turn only 90˚.  
7
M968677 Rev. 1.1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
1
RE-ATTACH  
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968677 Rev. 1.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
LOGO  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
LOGO  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
180˚  
LOOP TOWARD  
FRONT OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Unlocked Mode  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968677 Rev. 1.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Installation  
Instructions  
3475.301  
COLONY/COLONY SOFT  
Bidet Faucet and Transfer Valve  
3475.501  
with SpeedConnect™ Drain  
Congratulations on purchasing your American  
Standard faucet with Speed Connect drain, a  
feature found only on American Standard faucets.  
Certified to comply with ANSI A112.18.1  
SpeedConnect Drain*  
M968796 Rev.1.1  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
Required tools  
Roughing-in Dimensions  
8 TO 12  
DIVERTER AND  
FINISHED  
TRANSFER VALVE  
(FOR FLUSHING  
RIM OR SPRAY)  
VACUUM BREAKER  
ASSEMBLY  
WALL  
BIDET OUTLINE  
IS SYMBOLIC  
Plumbers' Putty or  
Caulking  
Screwdriver  
2-1/4  
DIA.  
(C)  
(H)  
7/8 DIA.  
1-3/16 DIA.  
1-1/4 MAX.  
DOUCHE  
SPRAY  
2-1/8  
DIA.  
ADJ. 1-1/4  
TO 2-1/4  
4-1/4  
Phillips Screwdriver  
Channel Locks  
Tubing Cutter  
FOR GROUND JOINT  
CONNECTION OR 1/2 "  
O.D. SLIP (INLETS)  
1-3/8  
DIA.  
3-7/8  
REAR VIEW WITH  
WALL REMOVED  
FINISHED  
FLOOR  
Adjustable Wrench  
5-1/2  
1-1/4 O.D. TAILPIECE  
Turn off hot and cold water  
supplies before beginning.  
BIDET FAUCET INSTALLATION CAUTION  
1
11  
6
7
Place RUBBER RING (10) into ADAPTER (4).  
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From  
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting  
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above  
mounting surface top. Fig. A. Thread ADAPTER (4) onto VALVE BODIES (3, 3a)  
until snug against internal stop. If necessary, adjust LOCKNUT (1).  
4
BIDET  
LEDGE  
10  
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)  
4
10  
MOUNTING  
SURFACE  
Fig. A.  
to secure VALVE BODIES (3, 3a).  
Remove MOUNTING NUT (6), WASHER (7) and  
UPPER GASKET (8) from TRANSFER VALVE (9).  
Insert TRANSFER VALVE (9) into the center forward  
hole of BIDET.  
5/16''  
MIN.  
3a  
3
COLD  
2
1
HOT  
8
2
1
9
Replace UPPER GASKET (8) and WASHER (7) . Position  
the side threaded outlet rearward and secure MOUNTING  
NUT (6). Thread ESCUTCHEON (11) onto TRANSFER  
VALVE (9) until it seats against the BIDET LEDGE.  
3, 3a  
5
8
2
9
1
SPRAY INSTALLATION  
2
PUTTY  
7
6
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside  
of SPRAY BODY FLANGE (2) and secure with NUT (3).  
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).  
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet  
NIPPLE (7) of the TRANSFER VALVE (8).  
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
POP-UP DRAIN  
3
4
Fig. A.  
Fig. B.  
DRAIN  
BODY  
Remove CLEAR PLASTIC COVER (1).  
1
3
Remove CARDBOARD SPACER (2) from under  
DRAIN POP-UP (3).  
Tighten TAILPIECE (4) on DRAIN BODY before  
installing DRAIN BODY. Fig. B.  
7
2
REMOVE FLANGE  
Fig. A.  
Fig. B.  
1
Thread FLANGE (1) counter-clockwise and remove  
FLANGE (1) and FOAM GASKET (2) from drain  
body. Fig. A.  
Thread LOCKNUT (3) clock-wise to bottom of  
drain body. Push GASKET (4) down against  
LOCKNUT (3). Fig. B.  
4
3
2
INSTALL DRAIN FROM  
BELOW FIXTURE  
TIGHTEN LOCKNUT  
5
7
6
Tighten LOCKNUT (1) firmly with Adjustable  
Wrench or Channel Locks.  
From under side of BIDET  
install DRAIN BODY (1) up  
4
through drain outlet.  
3
Note: No plumber’s putty  
or caulk is required.  
The CABLE ATTACHMENT  
POINT (2) must face towards  
the rear of the BIDET.  
DRAIN  
OUTLET  
1
2
1
Install FOAM GASKET (3) and  
FLANGE (4) onto drain body  
from above BIDET and tighten  
FLANGE (4) firmly.  
FLANGE GASKET  
Fig. A.  
Fig. B.  
1
Check DRAIN FLANGE in BIDET to ensure that WHITE  
FOAM GASKET (1) is fully compressed and not visible.  
Fig. A.  
3
DRAIN  
FLANGE  
5
POP-UP ROD ASSEMBLY  
SLOTTED  
MOUNTING  
NUT  
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2)  
through rear hole, making sure SEAL WASHER (3) is  
properly seated. Fig. B.  
4
WHITE FOAM  
GASKET  
NOT VISIBLE  
1
ILLUSTRATION  
SHOWN LESS  
VALVES  
2
From below slip slot in MOUNTING NUT (4) over CABLE (5).  
Thread NUT (4) onto lift rod guide shank to secure ROD  
GUIDE (1) to bidet. Hand tighten only. Fig. B.  
M968796 Rev.1.1  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACH CABLE  
CONNECTOR  
8
9
Fig. A.  
Fig. B.  
Fig. C.  
DOWN  
POP-UP KNOB (1) must be fully  
down. Fig. A.  
1
Thread CABLE CONNECTOR (1)  
clockwise onto DRAIN BODY  
CONNECTION (2) and hand  
tighten. Fig. B.  
Your new POP-UP DRAIN  
installation is now complete.  
Fig. C.  
2
1-1/4” O.D.  
Note: Tailpeice on pop-up drain  
is 1-1/4” O.D. Fig. C.  
CHECK OPERATION OF POP-UP  
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)  
opens and closes.  
3
1
1
Note: If STOPPER (2) does not open and close properly  
then refer to the “troubleshooting section” of these  
instructions.  
2
INSTALL DIVERTER KNOB  
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).  
Push on RING (3) and tighten with SCREW (4).  
Press on KNOB CAP (5).  
Note: Screwdriver gap is for disassembling and should  
point downwards.  
TEE AND HOSE CONNECTION  
10  
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to  
bottom of TRANSFER VALVE (3).  
Install SEAL (4) into coupling nut of TEE (5) and tighten  
connection to ADAPTER (2).  
3
7a  
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve  
bodies and securely tighten.  
6
2
1
4
Front  
5
COUPLING  
NUT  
WATER SUPPLY CONNECTION  
6
7
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT  
INCLUDED AND MUST BE PURCHASED SEPARATELY.  
3
3/8 O.D.  
BULL-NOSE  
RISERS  
1/2" PIPE  
THREAD  
Connect water supply to VALVE BODIES (7,7a) with  
1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE  
RISERS (3). Use adjustable wrench to tighten connections.  
Do not over tighten. Be careful not to kink copper supply when  
bending. Use tubing cutter to cut to proper length.  
COMPRESSION  
NUT  
2
FLEXIBLE  
SUPPLIES  
FERRULE  
Connect HOT water supply to inlet of left SHANK and COLD  
water supply to right SHANK using sealant, appropriate  
connectors, and COUPLING NUTS.  
COLD  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
CONNECT TO  
WASTE OUTLET  
HOT  
3/8 COMPRESSION  
CONNECTION  
M968796 Rev.1.1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALL HANDLES (Lever)  
INSTALL HANDLES (Acrylic)  
11  
Turn HANDLE STEM (1) to "OFF"  
position.  
Turn HANDLE STEM (1) to "OFF"  
position.  
4
3
Place the ACRYLIC HANDLE (2)  
on the HANDLE STEM (1).  
Place the HANDLE ADAPTER (2)  
on the HANDLE STEM (1).  
5
4
3
Install the HANDLE SCREW (3)  
and tighten securely.  
Install the ADAPTER SCREW (3)  
and tighten securely. Position  
LEVER HANDLE (4) and place  
on ADAPTER (2).  
Push in INDEX BUTTON (4).  
2
1
2
1
Install the HANDLE SCREW (5)  
and tighten securely with hex  
wrench supplied.  
TEST INSTALLED FITTING  
12  
5
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
1
3
Operate both HANDLES (1) to flush water  
lines thoroughly.  
Rotate TRANSFER VALVE (5) from rim wash to  
spray several times to check operation.  
1
4
CHECK DRAIN CONNECTIONS  
13  
SPRAY  
Pull up POP-UP KNOB (3) and fill Bidet with water. Check  
that DRAIN STOPPER (4) makes a good seal and retains  
water in Bidet. If STOPPER (4) does not seal properly,  
please refer to “Troubleshooting Guide” in these instructions.  
2
Push POP-UP KNOB (3) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
2
SERVICE  
EverClean™ Finish  
Care Instructions  
To change direction of handle  
rotation, proceed as follows:  
14  
15  
1
Turn VALVE to OFF position.  
Loosen HANDLE SCREW (1) .  
American Standard’s EverClean  
finish will wipe clean with a soft,  
dry cloth.  
A soft cloth with clean water  
may also be used, if desired.  
No additional cleaning products  
are required.  
2
4
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER  
SCREW (4) and pull off ADAPTER (3).  
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3)  
catches on the other FLAT on VALVE STEM (5).  
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).  
Tighten HANDLE SCREW (1).  
3
5
DO NOT USE: Soaps, acid,  
polish, abrasives, harsh  
cleaners, or a cloth with a  
coarse surface.  
If spout drips, operate handles several  
times from OFF to ON position. Do not  
force - handles turn only 90˚.  
M968796 Rev.1.1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SpeedConnect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
1
RE-ATTACH  
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968796 Rev.1.1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
LOGO  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
LOGO  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
180˚  
LOOP TOWARD  
FRONT OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Unlocked Mode  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968796 Rev.1.1  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch 3C16751A User Manual
ACCO Brands Range GBC 2064WF 1 User Manual
Agilent Technologies Portable Generator 75000 Series C User Manual
AKG Acoustics Music Mixer DMM 12BC User Manual
Alcatel Lucent Network Card Eye Box User Manual
Alpine Car Stereo System 68 13530Z42 A User Manual
Amana Furnace GUD X User Manual
Audiovox Satellite Radio SIR PNP2 User Manual
Axis Communications Security Camera P1204 User Manual
BC Speakers Speaker 18TBX100 User Manual