PRECAUTIONS / SAFETY WARNINGS  
1
·
To turn off the main power, disconnect the  
power cord which powers the AC socket on the  
PNP515/517 pop-up panel. The power outlet  
used should be installed as near to the  
equipment as possible and should be easily  
accessible.  
Please read this manual carefully before using your  
PNP515/517 Interconnect Box. Keep this manual  
handy for future reference. These safety  
instructions are to ensure the long life of your  
PNP515/517 and to prevent fire and shock  
hazards. Please read them carefully and heed all  
warnings.  
·
·
ALTINEX recommends using wall outlets with a  
Ground Fault Circuit Interrupter (GFCI) for  
maximum protection.  
1.1 GENERAL  
Install all cables according to the instructions. Do  
not force or pull out any cable or power cord that  
is attached to the PNP515/517.  
·
Unauthorized personnel shall not open the unit  
since there are high-voltage components inside.  
·
Qualified ALTINEX service personnel, or their  
authorized representatives, must perform all  
service.  
1.3 CLEANING  
·
Surfaces should be cleaned with a dry cloth.  
Never use strong detergents or solvents such as  
alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
1.4 FCC NOTICE  
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
·
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
1.2 INSTALLATION PRECAUTIONS  
·
For best results, place the PNP515/517 in a dry  
area away from dust and moisture.  
·
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the  
PNP515/517 in direct sunlight, near heaters or  
heat-radiating appliances, or near any liquid.  
Exposure to direct sunlight, smoke, or steam can  
harm internal components.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instructions found herein, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his expense.  
·
·
Handle the PNP515/517 carefully. Dropping or  
jarring can damage the unit.  
Never place fingers inside the openings of the  
unit. This action could cause serious injury due  
to sharp edges inside the PNP515/517.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
·
Do not place heavy objects on top of the  
PNP515/517. Do not use excessive force to  
push down on the top of the unit.  
400-0464-003  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
ABOUT YOUR PNP515/517  
2
TECHNICAL SPECIFICATIONS  
3
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
PNP515/517  
Pop ‘N Plug with Custom Tabletop Surface  
FEATURES/  
PNP515/517  
DESCRIPTION  
·
·
·
·
·
·
·
Customizable to almost any table top  
Several standard international configurations  
Smooth new look on all sides  
Cutout always matches table surface  
Simple, slide-in installation  
Inputs (female) /  
Outputs (male)  
PNP517  
AC Power  
Video  
NEMA 5-15 (8)  
15-pin HD (4)  
3.5mm (4)  
RJ-45 (4)  
Opens/closes by pressing on top  
Gas spring lift mechanism  
Computer Audio  
Network  
This Pop ‘N Plug uses a custom tabletop cutout  
surface, and hardware is attached underneath the  
cutout. When closed, the PNP515/517 lays flat and  
matches the grain on your table.  
Modem  
RJ-11 (4)  
C-Video  
RCA (2)  
Compatibility  
PNP515  
The PNP515/517 design allows the connector  
panels to be easily installed. Just remove the top  
and slide the connector panels into place. In the  
open position, the PNP515/517 is functional yet  
maintains a smooth, clean appearance. A simple  
press on the lid closes the unit flush with the  
tabletop.  
DS901-122 for UK,  
Accepts DS901  
STANDARD  
sectional plates. *  
DS901-123 for Australia,  
DS901-124 for Germany,  
DS901-128 blank,  
DS901-130 for US  
DS901-125 for UK,  
DS901-126 for Australia,  
DS901-127 for Germany,  
DS901-131 for US  
Accepts DS901  
CONFIGURABLE  
sectional plates. *  
The PNP515 can be purchased with preconfigured  
options available that include two standard  
sectional plates.* Each plate includes one or more  
of the following: AC power, computer video, stereo  
audio, modem, or network connections. The AC  
power receptacles on the face plates are available  
with US or international connections.  
Table 1. PNP515 General  
MECHANICAL  
Min. Table Thickness  
Max. Table Thickness  
Max. weight of custom top  
Width  
PNP515/517  
0.750 in (19 mm)  
1.125 in (29 mm)  
22 oz (0.624 kg)  
5.65 in (144 mm)  
5.45 in (138 mm)  
5.10 in (130 mm)  
8.75 in (222 mm)  
8.50 in (216 mm)  
6.125 in (156 mm)  
Matte Black  
All connectors on the face plates are female  
receptacles. Each signal connector is connected  
via a 6-foot cable to its corresponding male plug at  
the opposite end. The AC power cables are 9-foot  
cords terminated with standard NEMA plugs for the  
US version, or with the applicable plug for  
international versions.  
Depth  
Height, opened  
Height  
Width  
Depth  
Finish  
(below tabletop)  
(below tabletop)  
(below tabletop)  
* See DIAGRAM 6 and DIAGRAM 7 for the  
available standard plates on both US and  
international units.  
T° Operating  
T° Maximum  
Humidity  
10°C-35°C  
40°C  
90% non-condensing  
Table 2. PNP515/517 Mechanical  
400-0464-003  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
ELECTRICAL  
PNP515/517  
Power Rating  
(pass through AC power)  
120VAC, 60Hz, 5A  
Table 3. PNP515/517 Electrical  
PRODUCT DESCRIPTION  
4
Table Surface  
RJ-45 (2)  
RJ-11 (2)  
Yellow RCA (1)  
3.5 mm Stereo (2)  
15-PIN HD (2)  
AC Power (4)  
Table Surface  
Table Surface  
NOTE:  
One side of the PNP517 connector installation is shown in the above diagram. The  
PNP517 has another of the same sectional plates facing the opposite side of the  
table. Various combinations of connectors, along with the applicable cable types,  
may be selected for customization at the time of purchase.  
Please, refer to the ALTINEX website (www.altinex.com) for specific customization  
options and instructions.  
400-0464-003  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
PNP517*  
Notebook Computer  
Floor box  
Notebook Computer  
* The PNP517 is shown as in the above diagram. The PNP517 is a standard configuration that includes the  
PNP515 and two DS901-301 standard face plates.  
400-0464-003  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
DIAGRAM 2: CUTOUT DIMENSIONS  
5.650"  
[144 mm]  
5.450"  
[138 mm]  
5.850"  
[149 mm]  
5.650"  
[144 mm]  
DIAGRAM 3: CLOSED DIMENSIONS  
3
9 ''  
4
[248 mm]  
3
8 ''  
4
[222 mm]  
400-0464-003  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
DIAGRAM 4: FRONT VIEW DIMENSIONS  
TABLE THICKNESS  
MIN. 3/4'' [19 mm]  
MAX. 1 1/8'' [29 mm]  
5 1/10''  
[130 mm]  
6 1/10''  
[155 mm]  
FRONT  
VIEW  
1
6 ''  
8
[156 mm]  
400-0464-003  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
DIAGRAM 5: SIDE VIEW DIMENSIONS  
SIDE  
VIEW  
7
14 ''  
8
[378 mm]  
3
9 ''  
4
[248 mm]  
1
8 ''  
2
[216 mm]  
400-0464-003  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
DIAGRAM 6: STANDARD PLATES US & UK  
DS901-130  
DS901-131  
Standard on PNP517 for United States.  
PNP517C with configurable snap-ins.  
DS901-122  
DS901-125  
Standard on PNP527 for United Kingdom.  
PNP527C with configurable snap-ins.  
400-0464-003  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
DIAGRAM 7: STANDARD PLATES AU & GR  
DS901-123  
DS901-122  
Standard on PNP537 for Australia.  
PNP537C with configurable snap-ins.  
DS901-124  
DS901-127  
Standard on PNP547 for Germany.  
PNP547C with configurable snap-ins.  
400-0464-003  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLETOP SOLUTIONS  
7.2 POWER/SIGNAL CONNECTIONS  
INSTALLING YOUR PNP515  
Step 1. Refer to the ALTINEX  
6
Connect external devices to the appropriate  
connector on the PNP. Remember, the devices  
plugged into the AC power connectors should not  
draw more than 5A AC.  
website,  
www.altinex.com, to download the latest  
templates and instructions for tabletop  
cutting requirements and installation  
instructions.  
TROUBLESHOOTING GUIDE  
8
In order to do this, locate the PNP515 on  
the website and go to its detail page. The  
links to the templates, user’s guide, and  
more are on the left-hand side of the  
screen.  
The PNP unit supplied was carefully tested and no  
problems were detected. However, we would like to  
offer the following suggestions:  
·
Please make sure that the highest quality  
network cables are used.  
Step 2. Print all information applicable to the  
installation of the PNP515, including the  
templates and any detailed installation  
instructions.  
·
Make sure that no cable or power cord is  
damaged or pinched. If there has been damage  
to the unit, do not use the PNP. Please contact  
ALTINEX at (714) 990-2300 to have the unit  
repaired.  
Step 3. Cut an opening into the table’s surface.  
This operation should be performed by  
experienced professionals in order to  
insure accuracy and to be aesthetically  
pleasing.  
ALTINEX POLICIES  
9
9.1 LIMITED WARRANTY/RETURN POLICIES  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
NOTE: Always confirm dimensions before  
cutting to insure that specifications have  
not changed.  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
Step 4. Install the PNP515 into the table per the  
installation instructions provided on the  
website.  
592 Apollo Street  
Step 5. Connect all cables to their appropriate  
sources and/or destinations. The PNP is  
now ready for operation.  
Brea, CA 92821 USA  
TEL: 714 990-2300  
TOLL FREE: 1-800-ALTINEX  
OPERATION  
7
7.1 OPENING AND CLOSING THE PNP515  
The PNP will open easily when the top is pressed  
down and then released.  
When the PNP is not in use, simply press the top  
down until it is level with the surface of the table  
and then release. The unit will remain hidden until  
needed again.  
400-0464-003  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Card ISDN Modem User Manual
3M Projector MP8625 User Manual
Acer Personal Computer G320 Series User Manual
AG Neovo Flat Panel Television F 17C User Manual
AKG Acoustics Microphone D5 User Manual
Alpine Car Stereo System VPA B222 User Manual
Altinex Switch MX2414RM User Manual
Asus Network Card E976 User Manual
Atlona Log Splitter AT HD V18 User Manual
BC Speakers Portable Speaker 12NCX User Manual