SWITCHER  
1.4 CLEANING  
PRECAUTIONS / SAFETY WARNINGS  
1
·
Unplug the SW1956CT power cord before  
cleaning. Clean surfaces with a dry cloth. Never  
use strong detergents or solvents such as  
alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
Please read this manual carefully before using your  
SW1956CT Switcher. Keep this manual handy for  
future reference. These safety instructions are to  
ensure the long life of your SW1956CT and to  
prevent fire and shock hazards. Please read them  
carefully and heed all warnings.  
1.5 FCC NOTICE  
1.1 GENERAL  
·
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
·
Qualified ALTINEX service personnel or their  
authorized representatives must perform all  
service.  
1.3 INSTALLATION  
·
For best results, place the SW1956CT on a flat,  
level surface. Keep in a dry area away from dust  
and moisture.  
This equipment has been tested and found to  
comply with the limits for a Class A digital device  
pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide reasonable  
protection against harmful interference when the  
·
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the  
SW1956CT in direct sunlight, near heaters or  
heat-radiating appliances, or near any liquid.  
Exposure to direct sunlight, smoke, or steam can  
harm internal components.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instructions found herein, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
·
·
Handle the SW1956CT carefully. Dropping or  
jarring can damage internal components.  
Do not place heavy objects on top of the  
SW1956CT. If the unit is to be mounted to a  
table or wall, use only ALTINEX-made mounting  
accessories.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
·
To turn off the main power, be sure to remove  
the cord from the power outlet. The power outlet  
socket should be installed as close to the  
equipment as possible, and should be easily  
accessible.  
·
·
Do not pull the power cord or any cable that is  
attached to the SW1956CT Switcher.  
If the SW1956CT is not to be used for an  
extended period, disconnect the power cord  
from the outlet.  
400-0378-004  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
ABOUT YOUR SW1956CT  
2
TECHNICAL SPECIFICATIONS  
3
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
SW1956CT  
2-In, 1 Out Twisted Pair Auto-Switcher  
FEATURES/  
SW1956CT  
The SW1956CT is a 2-In, 1-Out Twisted Pair  
Auto-Switcher. The SW1956CT switches  
DESCRIPTION  
Inputs  
automatically upon signal detection, but may also  
be controlled manually. The SW1956CT is  
designed to switch ALTINEX Twisted Pair  
transmitter and receiver signals. These include  
ALTINEX part numbers DA1930CT, DA1931CT,  
MT103-122, MT103-123, etc.  
Input Connector  
Power  
RJ-45 female (2)  
2.5mm DC jack (1)  
Outputs  
Output Connector  
Compatibility  
RJ-45 female (1)  
The unit is encased in a solid metal enclosure and  
ships with an external, 9V power adapter. Also  
included is an external contact-closure switch for  
manual override of input selection.  
ALTINEX Standard for  
Twisted Pair  
Signal Types  
Manual override switching is made via a contact  
closure on the Input Select jack. This switch may  
be used for manual control, or the contact closure  
may be controlled from a control system.  
Video Signal  
Resolutions  
VGA through UXGA,  
480p through 1080i  
VGA:  
640x480@60Hz  
900 ft (274 m)  
The SW1956CT is perfect for applications that use  
wall or floor plates for auto-switching. The  
SW1956CT may be mounted to furniture or other  
suitable surfaces using optional hardware.  
Recommended Max.  
Cable Lengths  
XGA:  
1024x768@60Hz  
700 ft (213 m)  
Note: Measurements  
made using ALTINEX  
low-skew cable,  
SXGA: 1280x1024@60Hz  
650 ft (198 m)  
The latest generation of Twisted Pair devices uses  
an innovative, patented technology* developed by  
ALTINEX. The new signal processing technology  
allows transmitting and receiving fully equalized  
computer video signals, stereo, and audio signals  
over long distances.  
CB3150PV.  
UXGA: 1600x1200@60Hz  
600 ft (183 m)  
Accessories Included  
Power Adapter  
+9 VDC, 500 mA  
Contact Closure  
* US Patent 7,065,190  
Remote Switch  
Table 1. SW1956CT General  
400-0378-004  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
SW1956CT  
MECHANICAL  
Material  
SW1956CT  
0.100 in Al  
ELECTRICAL  
Input Signal  
Finish  
Gray  
Analog Signal  
1.0 Vp-p max  
Height  
3.000 in ( 76 mm)  
4.380 in (111 mm)  
1.000 in ( 25mm)  
0.40 lb (0.18 kg)  
2.00 lb (0.91 kg)  
10°C-35°C  
Output Video Signals  
Analog Signal  
Width  
1.0 Vp-p max  
Depth  
Frequency Compatibility  
Horizontal  
Weight  
15-200 kHz  
20-190 Hz  
Ship Weight  
T° Operating  
T° Maximum  
Humidity  
Vertical  
Cross-talk  
-40 dB @ 10 MHz  
DC  
Coupling  
50°C  
Power Consumption  
External Adapter: 9 VDC  
90% non-condensing  
40,000 hrs (min.)  
MTBF (calculations)  
350 mA (3 W max.)  
Table 2. SW1956CT Mechanical  
Table 3. SW1956CT Electrical  
400-0378-004  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
PRODUCT DESCRIPTION  
4
400-0378-004  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
ALTINEX includes a remote control switch with the SW1956CT. The remote switch has a 6 ft cable and  
may used to control the switcher manually.  
When the remote control switch is connected to the INPUT SELECT jack, INPUT 1 will be selected if the  
channel select contact is closed. INPUT 2 will be selected if the channel select contact is open.  
The switching will be identical whether there are one or two active signals. The LEDs located next to the  
input ports indicate which input is selected.  
SW1956CT  
400-0378-004  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
DIAGRAM 2: INTERNAL VIEW  
CONTACT  
CLOUSURE  
SIGNAL  
DETECT  
INPUT1  
OUTPUT  
TWISTED  
PAIR  
TWISTED  
PAIR  
INPUT1  
INPUT2  
RJ-45  
RJ-45  
INPUT2  
POWER  
SUPPLY  
2.5 mm  
9 VDC, 500 mA  
400-0378-004  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
INSTALLING YOUR SW1956CT  
6
OPERATION  
7
Step 1. Connect the ALTINEX power adapter that  
There are no settings to adjust on the SW1956CT  
Auto-Switcher. The SW1956CT will operate  
successfully as long as cables are attached  
properly and other technical specifications are  
followed.  
is supplied with the unit to the power port.  
CAUTION: The POWER port and the  
INPUT SELECT port use the  
same connector type. Make  
sure the power adapter is  
connected to the POWER  
port.  
AUTO-SWITCH MODE  
The SW1956CT automatically selects the INPUT 2  
port if there are no active signals present. If there is  
an active signal on INPUT 2 and not on INPUT 1,  
then the SW1956CT will maintain INPUT 2 as the  
active port. However, when an active signal is  
applied to INPUT 1, the SW1956CT will switch to  
INPUT 1.  
Step 2. The POWER LED and the INPUT 2 LED  
should turn on.  
Step 3. Connect the SW1956CT inputs to the  
outputs of the Twisted Pair transmitters.  
Step 4. Connect a cable from the output port of  
the SW1956CT to the input port of the  
Twisted Pair receiver.  
If there are active signals on INPUT 1 and  
INPUT 2, the SW1956CT will automatically switch  
to INPUT 1.  
Step 5. If the remote control switch is to be used,  
MANUAL SWITCH MODE  
connect it to the INPUT SELECT port.  
Manual override is accomplished via a contact  
closure on the INPUT SELECT jack. Manual Switch  
Mode disables auto-switching.  
CAUTION: The POWER port and the  
INPUT SELECT port use the  
same connector type. Make  
sure the control switch is  
connected to the INPUT  
SELECT port.  
Included with the SW1956CT is an external manual  
switch with a 6 ft cable. This switch may be used  
for manual control, or the contact closure may be  
made from a control system. This port uses a  
2.5 mm mini-coaxial remote-control jack and it is  
located next to the Twisted Pair output.  
Step 6. Verify that the picture quality on the  
display is good. If a signal is not being  
received, make sure that the display is  
compatible with the resolution of the  
computer graphics card.  
INPUT 1 will be selected when the remote control  
switch is connected to the INPUT SELECT jack and  
the contact is closed. INPUT 2 will be selected if  
the contact is open.  
CAUTION:  
The connector used for the INPUT  
SELECT port is the same type as is  
used for the POWER connector. Use  
caution to ensure the switch is  
connected to the correct port.  
400-0378-004  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
Cause 2: The signal is not active or is  
improperly formatted.  
TROUBLESHOOTING GUIDE  
8
We have carefully tested and have found no  
problems in the supplied SW1956CT unit.  
However, we would like to offer the following  
suggestions:  
Solution 1: Remove the input signals from the  
switcher. If the IN 2 LED is off, call  
ALTINEX at (714) 990-2300. If the  
IN 2 LED is on, see Solution 2.  
8.1 POWER LED IS OFF  
Solution 2: Connect a properly formatted signal  
from an ALTINEX Twisted Pair  
transmitter to INPUT 1. If the  
switcher does not switch to  
INPUT 1, see Solution 3.  
Cause 1: The power adapter is installed  
wrong.  
Solution 1: Make sure the adapter output is  
connected to the POWER input jack  
on the unit. Check the unit carefully.  
The POWER input jack and the  
INPUT SELECT jack are the same  
type. If the POWER LED is still not  
on, see Solution 2.  
Solution 3: Bypass the switcher and connect the  
output of the transmitter directly to  
the input of the receiver. If the  
display is good, then call ALTINEX  
at (714) 990-2300.  
Solution 2: Make sure the adapter is plugged  
into a proper AC outlet that has  
power. If the adapter has AC power  
and the POWER LED is still off, see  
Cause 2.  
8.3 NO DISPLAY  
Cause 1: The source has a problem.  
Solution: Check the source and make sure  
that there is a signal present and all  
source connections are correct. If  
the source is working and there is  
still no display, see Cause 2.  
Cause 2: The wrong power adapter is  
installed.  
Solution 1: Please use the ALTINEX supplied  
external adapter (9 V, 500 mA). If  
Cause 2: Manual override is on.  
the POWER LED is still not on,  
Solution: Make sure there is nothing  
connected to the INPUT SELECT  
port on the switcher. If there is  
nothing connected, see Cause 3.  
please  
call  
ALTINEX  
at  
(714) 990-2300.  
8.2 UNIT DOES NOT AUTO-SWITCH  
Cause 3: Signal is bad or missing.  
Cause 1: The manual override switch is  
installed.  
Solution 1: Make sure the switcher output is  
connected to the Twisted Pair  
receiver input and the receiver is on.  
If there is still no display, see  
Solution 2.  
Solution: Remove the connection to the  
INPUT SELECT jack on the unit. If a  
plug is installed in the jack, the  
SW1956CT will not auto-switch  
properly. If the unit does not  
auto-switch with the plug removed,  
see Cause 2.  
Solution 2: Remove both inputs to the switcher  
and connect the active signal from  
the Twisted Pair transmitter output  
to INPUT 2. If there is still no  
display, see Solution 3.  
400-0378-004  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHER  
Solution 3: Bypass the switcher and connect the  
output of the transmitter directly to  
the input of the receiver. If the  
display is good, then call ALTINEX  
at (714) 990-2300. If there is still no  
display, see Cause 4.  
ALTINEX POLICIES  
9
9.1 LIMITED WARRANTY/RETURN POLICIES  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
Cause 4: Cable connections are incorrect.  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
Solution: Make sure that cables are properly  
connected. Also, make sure that the  
continuity and wiring are good. If  
there is still no display present, see  
Cause 5.  
592 Apollo Street  
Brea, CA 92821 USA  
TEL: 714 990-2300  
Cause 5: The display has a problem.  
TOLL FREE: 1-800-ALTINEX  
Solution: Make sure the display is powered  
and is turned on. If there is still no  
display, please call ALTINEX at  
(714) 990-2300.  
400-0378-004  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Accton Technology Network Hardware 1000BASE SX Gigabit Uplink Module User Manual
ADC Network Card InterReach User Manual
ADC Switch Programmable Series User Manual
AKG Acoustics Headphones 2908Z00190 User Manual
American DJ Work Light Nitro User Manual
Audiovox Car Stereo System ACD 84 User Manual
Aviom Musical Instrument MH10f User Manual
Axor Plumbing Product 42028820 User Manual
Behringer Music Pedal DI600P User Manual
Beko DVD Player DVD 7300 User Manual