Alliance Laundry Systems Clothes Dryer Drying Cabinet User Manual |
Drying Tumblers
Stacked 30 Pound Capacity
Stacked 45 Pound Capacity
Starting Serial No. 0602004144
NOTA: Para bajar una
copia de estas
instrucciones en
español, visite
HIGH
TEMP
STA
RT
LOW
TEMP
MED
TEMP
NO
HEAT
25
C
1
SELE
TEMP
2
INSE
CT
RT
3
PUS
COIN
HIG
H
TEM
P
H
STAR
T
STA
RT
LOW
1
TEMP
MED
TE
SELE
TEMP
2
INSE
COIN
CT
MP
RT
3
PUS
NO
H
HEA
T
STAR
T
25
C
T477C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 70304601R6
February 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation must conform with local codes or in the absence of local codes with:
In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/
NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Installation
Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia, installation must comply with the Australian Gas Association Installation Code for Gas
Burning Appliances and Equipment.
WARNING
MISE EN GARDE
POUR VOTRE SÉCURITÉ, les informations
de ce guide doivent être respectées afin de
réduire les risques d’incendie, d’explosion
ou d’éviter les dommages matériels,
FOR YOUR SAFETY, the information in this
manual must be followed to minimize the
risk of fire or explosion or to prevent
property damage, personal injury or death.
W033
personnels ou blessures mortelles.
W033R3QU
• Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Clear the room, building or area of all
occupants.
– Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
– If you cannot reach your gas supplier,
call the fire department.
• Ne pas entreposer ou utiliser d’essence
ou toutes autres vapeurs et liquides
inflammables à proximité de cette
machine ou de tout autre appareil.
• QUE FAIRE EN CAS D’ODEUR DE GAZ :
– Ne pas mettre d’appareil en marche.
– Ne pas toucher aux interrupteurs
électriques ; ne pas utiliser le
téléphone des lieux.
– Évacuer la pièce, le bâtiment ou la zone
de tous les occupants.
– Appeler immédiatement le fournisseur
de gaz de la maison d’un voisin.
Respecter les instructions
communiquées par le fournisseur.
– Si vous ne pouvez pas joindre le
fournisseur de gaz, appeler le service
d’incendie.
• Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
W052
FOR YOUR SAFETY
• L’installation et l’entretien doivent être
effectués par un installateur, service
d’entretien qualifiés ou par le fournisseur
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
de gaz.
W052R5QU
W053
POUR VOTRE SÉCURITÉ
The following information applies to the state of
Massachusetts, USA.
Ne pas entreposer ou utiliser d’essence ou
toutes autres vapeurs et liquides
inflammables à proximité de cette unité ou
•
•
•
This appliance can only be installed by a
Massachusetts licensed plumber or gas fitter.
de tout autre appareil.
W053R2QU
This appliance must be installed with a 36
inch (91 cm) long flexible gas connector.
IMPORTANT: Information must be obtained from
a local gas supplier on instructions to be followed if
the user smells gas. These instructions must be
posted in a prominent location. Step-by-step
instructions of the above safety information must
be posted in a prominent location near the tumbler
for customer use.
A "T-Handle" type gas shut-off valve must be
installed in the gas supply line to this
appliance.
•
This appliance must not be installed in a
bedroom or bathroom.
70304601
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Introduction.........................................................................................
4
Table of
Contents
Safety Information..............................................................................
6
Specifications and Dimensions...........................................................
9
Installation........................................................................................... 15
Exhaust Requirements ....................................................................... 24
Layout................................................................................................... 24
Make-Up Air......................................................................................... 24
Venting ................................................................................................. 24
Gas Requirements............................................................................... 30
© Copyright 2008, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Steam Requirements........................................................................... 43
Installing Steam Trap and Making Condensate
Return Connections............................................................................ 44
Single Drop Timer .............................................................................. 46
Power-Up Mode.................................................................................... 46
Ready Mode.......................................................................................... 46
Start Mode ............................................................................................ 46
Run Mode ............................................................................................. 46
Dipswitch Settings................................................................................ 47
Adjustments......................................................................................... 49
Airflow Switch...................................................................................... 49
Door Strike............................................................................................ 50
70304601
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Model Identification
Information in this manual is applicable to these models:
Gas
Steam
Electric
CHD30STG2-CAT30L
CHD30STG2-CAT30N
CHD30STG2-CTT30L
CHD30STG2-CTT30N
CHD30STG2-CUT30L
CHD30STG2-CUT30N
DRST30G2-BAT30L
DRST30G2-BAT30N
DRST30G2-BTT30L
DRST30G2-BTT30N
DRST30G2-BUT30L
DRST30G2-BUT30N
HAT30L
MTT30N
NTT30N
SAT30L
SAT30N
STT30D
STT30L
STT30N
SUT30L
SUT30N
UAT30L
UAT30N
UTT30L
UTT30N
UUT30L
UUT30N
CHD30STS2-CTT30S
CHD30STS2-CUT30S
DRST30S2-BTT30S
DRST30S2-BUT30S
HTT30S
HUT30S
IPD30STS2-ITT30S
STT30S
CHD30STE2-CTT30E
CHD30STE2-CUT30E
DRST30E2-BTT30E
DRST30E2-BUT30E
HTT30E
HUT30E
IPD30STE2-ITT30E
STT30E
SUT30S
UTT30S
UUT30S
SUT30E
UTT30E
UUT30E
T30
HAT30N
HTT30D
HTT30L
HTT30N
HUT30L
HUT30N
IPD30STG2-ITT30L
IPD30STG2-ITT30N
CTT45L
CTT45N
HTT45L
HTT45N
ITT45L
ITT45N
MTT45N
NTT45N
STT45L
STT45N
UTT45L
UTT45N
Not Applicable
Not Applicable
T45
Includes models with control suffixes:
3O– DX4 OPL
BY– basic electronic, prep for card
NC– NetMaster coin
SD– single drop
3V– DX4 vended
SX– single drop, prep for coin
ZC– NetMaster network coin
3X– DX4 prep for coin
BC– basic electronic, coin
BL– basic electronic, central pay
BX– basic electronic, prep for coin
NR– NetMaster card
NX– NetMaster, prep for coin
NY– NetMaster, prep for card
QT– dual digital timer
ZR– NetMaster network card
ZX– NetMaster network, prep for coin
ZY– NetMaster network, prep for card
Customer Service
Wiring Diagram
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
The wiring diagram is located in the upper junction or
upper contactor box.
The wiring diagram part number is located in the
lower portion of the electrical data on the serial plate.
For technical assistance, call (920) 748-3121.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
4
Introduction
Serial Plate Location
When calling or writing for information about your
product, be sure to mention model and serial numbers.
Model and serial numbers are found on serial plate on
the rear of machine and inside door.
1
TMB1974N
1
Serial Plate
Conversion Table
To Obtain Multiply
kCal
Multiply
By
By
0.06895
0.070
0.454
33,479
34.5
To Obtain
Btu
Btu
Inch
0.252
1055
25.4
Pounds/sq. inch
Pounds/sq. inch
Pounds (lbs.)
Boiler Horsepower
Boiler Horsepower
CFM
Bars
Joules
kg/sq. cm
Kilograms
Btu/hr.
Millimeters
Pounds/sq. inch
kPa
Inches W.C.
Inches W.C.
0.036
0.249
6.895
28.32
lbs. steam/hr.
liters/second
Btu/hr.
2
lb/inch (psi)
kPa
0.471
3414
3
ft
Liters
kW
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Information
Explanation of Safety Messages
WARNING
Precautionary statements (“DANGER,” “WARNING,”
and “CAUTION”), followed by specific instructions,
are found in this manual and on machine decals. These
precautions are intended for the personal safety of the
operator, user, servicer, and those maintaining the
machine.
Failure to install, maintain, and/or operate
this machine according to manufacturer’s
instructions may result in conditions which
can produce serious injury, death and/or
property damage.
W051R1
DANGER
NOTE: The WARNING and IMPORTANT
instructions appearing in this manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense, caution and carefulness are
factors which CANNOT be built into this tumbler.
These factors MUST BE supplied by the person(s)
installing, maintaining or operating the tumbler.
Indicates an imminently hazardous
situation that, if not avoided, will cause
severe personal injury or death.
WARNING
Indicates a hazardous situation that, if not
avoided, could cause severe personal
injury or death.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
do not understand.
CAUTION
Indicates a hazardous situation that, if not
avoided, may cause minor or moderate
personal injury or property damage.
Additional precautionary statements (“IMPORTANT”
and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
6
Safety Information
14. The interior of the tumbler and the exhaust duct
should be cleaned periodically by qualified
service personnel.
Important Safety Instructions
Save These Instructions
15. If not installed, operated and maintained in
accordance with the manufacturer’s instructions
or if there is damage to or mishandling of this
product’s components, use of this product could
expose you to substances in the fuel or from fuel
combustion which can cause death or serious
illness and which are known to the State of
California to cause cancer, birth defects or other
reproductive harm.
WARNING
Hazardous Voltage. Can cause shock, burn
or cause death. Allow machine power to
remain off for two minutes prior to working
in and around AC inverter drive.
W359
1. Read all instructions before using the tumbler.
16. Tumbler will not operate with the loading door
open. DO NOT bypass the door safety switch to
permit the tumbler to operate with the door open.
The tumbler will stop tumbling when the door is
opened. Do not use the tumbler if it does not stop
tumbling when the door is opened or starts
tumbling without pressing or turning the START
mechanism. Remove the tumbler from use and
call for service.
2. Refer to the GROUNDING INSTRUCTIONS
for the proper grounding of the tumbler.
3. Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry cleaning solvents, other flammable
or explosive substances as they give off vapors
that could ignite or explode.
4. Do not allow children on or in the tumbler. This
appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
17. Tumbler will not operate with lint panel open.
DO NOT bypass lint panel safety switch to
permit the tumbler to operate with the lint panel
open.
5. Before the tumbler is removed from service or
discarded, remove the door to the drying
compartment and the door to the lint
compartment.
18. Do not put articles soiled with vegetable or cooking
oil in the tumbler, as these oils may not be
removed during washing. Due to the remaining
oil, the fabric may catch on fire by itself.
6. Do not reach into the tumbler if the cylinder is
revolving.
19. To reduce the risk of fire, DO NOT put clothes
which have traces of any flammable substances
such as machine oil, flammable chemicals,
thinner, etc. or anything containing wax or
chemicals such as in mops and cleaning cloths, or
anything dry-cleaned at home with dry-cleaning
solvent in the tumbler.
7. Do not install or store the tumbler where it will
be exposed to water and/or weather.
8. Do not tamper with the controls.
9. Do not repair or replace any part of the tumbler,
or attempt any servicing unless specifically
recommended in the user-maintenance
instructions or in published user-repair
instructions that you understand and have the
skills to carry out.
20. Use the tumbler only for its intended purpose,
drying fabrics.
21. ALWAYS disconnect and lockout the electrical
power to the tumbler before servicing. Disconnect
power by shutting off appropriate breaker or fuse.
10. Do not use fabric softeners or products to
eliminate static unless recommended by the
manufacturer of the fabric softener or product.
22. Install this tumbler according to the
INSTALLATION INSTRUCTIONS. All
connections for electrical power, grounding, and
gas supply must comply with local codes and be
made by licensed personnel when required.
11. To reduce the risk of fire, DO NOT DRY plastics
or articles containing foam rubber or similarly
textured rubberlike materials.
12. Always clean the lint filter daily.
13. Keep area around the exhaust opening and
adjacent surrounding area free from the
accumulation of lint, dust and dirt.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
7
Safety Information
23. Remove laundry immediately after tumbler stops.
29. DO NOT bypass any safety devices.
24. Always read and follow manufacturer’s
instructions on packages of laundry and cleaning
aids. Heed all warnings or precautions. To reduce
the risk of poisoning or chemical burns, keep
them out of reach of children at all times
(preferably in a locked cabinet).
30. Solvent vapors from dry-cleaning machines
create acids when drawn through the heater of the
drying unit. These acids are corrosive to the
tumbler as well as to the laundry load being
dried. Be sure make-up air is free of solvent
vapors.
25. Do not tumble fiberglass curtains and draperies
unless the label says it can be done. If they are
dried, wipe out the cylinder with a damp cloth to
remove particles of fiberglass.
31. Failure to install, maintain, and/or operate this
machine according to the manufacturer’s
instructions may result in conditions which can
produce bodily injury and/or property damage.
26. Always follow the fabric care instructions
supplied by the garment manufacturer.
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
27. Never operate the tumbler with any guards and/or
panels removed.
to rear of tumblers.
28. DO NOT operate the tumbler if it is smoking,
W055
grinding, has missing or broken parts.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
8
Specifications and Dimensions
Specifications
T30
T45
66 dBA
67 dBA
Noise level measured during operation at operator
position of 3.3 feet (1 meter) in front of machine and
5.2 feet (1.6 meters) from floor.
544
(247)
673
(305)
Net Weight (approximate):
Pounds (kg)
30 x 26
(762 x 660)
33 x 30
(838 x 762)
Cylinder Size:
Inches (mm)
2 x 30
(2 x 13.6)
2 x 45
(2 x 20.5)
Cylinder Capacity (dry weight)
Pounds (kg)
1/4
1/4
1/2
1/2
Drive Motor Horsepower**
Fan Motor Horsepower**
50 Hertz
340
(160)
N/A
Maximum Airflow per Pocket**:
C.F.M. (l/sec)
60 Hertz
50 Hertz
60 Hertz
400
(189)
600
(283)
0.8
(2.0)
N/A
Maximum Static Back Pressure*:
Inches W.C. (mbar)
0.9
0.9
(2.3)
(2.3)
Gas Models
1/2 in. NPT
1/2 in. NPT
Gas Connection
73,000
(21.4, 77)
95,000
(27.8, 100.2)
Gas Burner Rating**:
Btu/hr (kW, Mj/hr)
Electric Models
Steam Models
21 kW
N/A
Heating Element Rating**:
Steam Connection
3/4 in. NPT
N/A
N/A
3.2
(111,000)
Steam Coil Rating at 100 psig**:
Boiler Horsepower (Btu/hr)
2.2
(74,000)
N/A
Steam Coil Rating at 15 psig**:
Boiler Horsepower (Btu/hr)
* with both pockets running
** for each pocket
N/A = Not Applicable
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications and Dimensions
Cabinet Dimensions
J
A
B
C
D
E
F
H
I
G
TMB2230N
Models
T30
A
B
C
D
E
28 in.
(711 mm)
48 in.
(1219 mm)
44 in.
(1118 mm)
11 in.
(279 mm)
10 in.
(254 mm)
31.88 in.
(810 mm)
49 in.
(1245 mm)
9 in.
(229 mm)
N/A
N/A
T45
Models
T30
F
G
H
I
J
25.02 in.
(636 mm)
42.76 in.
(1086 mm)
27.38 in.
(695 mm)
31.5 in.
(800 mm)
76.25 in.
(1937 mm)
29.37 in.
(746 mm)
48.62 in.
(1235 mm)
30.50 in.
(775 mm)
34.5 in.
(876 mm)
81.25 in.
(2063.75 mm)
T45
N/A = Not Applicable
NOTE: To meet ADA compliance, install a 4 inch
(102 mm) riser on T30 models only.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications and Dimensions
Exhaust Outlet Locations
A
B
C
TMB1969N
Rear Exhaust
Models
Diameter
A
B
C
Elliptical
T30
36.54 in.
(928 mm)
4.25 in.
(108 mm)
62.42 in.
(1585 mm)
Fits 8 in. (203 mm)
Elliptical
T45
40.88 in.
(1038 mm)
4.75 in.
(121 mm)
66.00 in.
(1676 mm)
Fits 10 in. (254 mm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications and Dimensions
Gas Connection Locations
C
B
1
A
TMB1970N
1
1/2 in. NPT
Gas Connection
B
Models
A
C
Non-CE and
75.20 in.
1.74 in.
36.84 in.
Non-Australian
(1910 mm)
(44 mm)
(936 mm)
T30
CE and
75.28 in.
2.5 in.
30.60 in.
Australian
(1912 mm)
(64 mm)
(777 mm)
78.75 in.
(2000 mm)
4.12 in.
(105 mm)
42.88 in.
(1089 mm)
T45
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications and Dimensions
Electrical Connection Locations
B
E
A
D
C
GAS AND STEAM
ELECTRIC
TMB1971N
Electric Service
C
Models
T30
Gas and Steam Models
Electric Models
A
B
D
E
59 in.
(1498 mm)
1.75 in.
(44 mm)
35.63 in.
(905 mm)
73.21 in.
(1859 mm)
2.28 in.
(58 mm)
62.5 in.
(1588 mm)
1.75 in.
(44 mm)
N/A
N/A
N/A
T45
N/A = Not Applicable
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications and Dimensions
Steam Connection Locations
C
D
A
B
A
B
TMB1972N
Inlet
Outlet
Models
A
C
B
D
73.93 in.
6.29 in.
62.71 in.
2.39 in.
T30
(Upper)
(1877 mm)
(160 mm)
(1592 mm)
(61 mm)
36.35 in.
6.29 in.
25.13 in.
2.39 in.
T30
(Lower)
(923 mm)
(160 mm)
(638 mm)
(61 mm)
NOTE: All connections use 3/4 inch NPT pipe.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Pre-Installation Inspection
Location Requirements
Upon delivery, visually inspect the crate, carton and
parts for any visible shipping damage. If the crate,
carton, or cover is damaged or signs of possible
damage are evident, have the carrier note the condition
on the shipping papers before the shipping receipt is
signed, or advise the carrier of the condition as soon as
it is discovered.
The tumbler must be installed on a level floor. Floor
covering materials such as carpeting or tile should be
removed.
To assure compliance, consult local building code
requirements. The tumbler must not be installed or
stored in an area where it will be exposed to water
and/or weather.
Remove the crate and protective cover as soon as
possible and check the items listed on the packing list.
Advise the carrier of any damaged or missing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles are damaged or
missing.
IMPORTANT: DO NOT block the airflow at the
rear of the tumbler with laundry or other articles.
Doing so would prevent adequate air supply to the
combustion chamber of the tumbler.
that the enclosure touches the tumbler top and side
panels. Also, note the minimum and maximum
dimensions. Local codes and ordinances must be
complied with.
IMPORTANT: Warranty is void unless tumbler is
installed according to instructions in this manual.
Installation should comply with minimum
specifications and requirements detailed herein,
and with applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access to
rear of tumblers.
W055
IMPORTANT: Install tumblers with sufficient
clearance for servicing and operation. Refer to
Material Required (Obtain Locally)
One fused disconnect switch or circuit
breaker.
All Models
IMPORTANT: Keep tumbler area clear and free
from combustible materials, gasoline and other
flammable vapors and liquids.
One gas shut-off valve for gas service
Gas Models
line to each tumbler.
One steam shut-off valve for steam
service line to be connected upstream of
solenoid steam valve.
Steam
Models
Steam shut-off valve for each condensate
return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.78 kg/sq. cm) working pressure for
connecting steam coils. Refer to
Figure 14 for sizing and connection
configurations.
Steam trap for steam coil outlet to
condensate return line.
Optional – Vacuum breaker for
condensate return line.
Table 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
15
Installation
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.
W056
1
3
4
2
5
6
7
TMB2110N
NOTE: Shaded areas indicate adjacent structure.
1
2
0.5 in. (13 mm) recommended between machines for removal or installation.
Allow 2 – 4 in. (51 – 102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
4 in. (102 mm) Maximum Header Thickness
3
4
5
6
12 in. (305 mm) Minimum Clearance
24 in. (610 mm) Minimum, 36 in. (914 mm) recommended for maintenance purposes.
Provision for Make-Up Air: Minimum 1.5 square feet T30 models, minimum 2 square feet T45 models. Location
for reference only. May be anywhere behind tumbler.
7
0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed.
Figure 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
The stacked tumbler has a fifth leveling leg which is
shipped in the up position. The fifth leveling leg
MUST BE installed properly on the lower left side of
the blower housing to stabilize the tumbler. Refer to
Position and Level the Tumbler
Unscrew the four shipping bolts (one at each corner).
Remove tumbler from skid carefully to avoid putting
pressure on the lower blower housing or motor
assembly.
After leveling with the four cabinet leveling legs,
lower the fifth leveling leg so it contacts the floor, and
then secure the screws.
NOTE: Do not throw bolts away – they are the
leveling legs.
Remove four nuts from the literature package, and
screw one fully on to each leveling leg.
CAUTION
Screw the four leveling legs (bolts) back into the level
adjusting fittings from the bottom.
The stacked drying tumbler has a 5th
leveling leg on the blower housing. It is very
important to properly adjust this leg. Unit is
Slide tumbler to its permanent location. Adjust the
leveling legs until the unit is level within 0.125 inch
Tumbler must not rock. Lock leveling legs with nuts
previously installed.
back heavy and could rock or tip.
W250
NOTE: The front of the tumbler should be slightly
higher than the rear (approximately 0.125 inch,
3.18 mm). This will prevent the clothes, while
tumbling, from wearing on the door glass gasket.
IMPORTANT: Keep tumbler as close to floor as
possible. The unit must rest firmly on floor so
weight of tumbler is evenly distributed.
1
T467I
1
Fifth Leg
Figure 3
TMB1975N
1
Leveling Leg
Figure 2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
IMPORTANT: The electronic ignition system will
attempt to light the gas by sparking for the “trial
not ignite within this period, the ignition control
will go into a safety lockout and the valve will no
longer open until the control is reset. It may be
necessary to retry several times to bleed air from
the gas lines. To reset, open and close the loading
door and restart tumbler.
Before Placing Tumbler into Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for tightness.
2. Replace all panels and guards.
3. Remove and discard wire tie from the airflow
IMPORTANT: Airflow switch operation may be
affected by:
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumbler from service.
• Clogged lint screen.
• Failure to remove wire tie from rear of
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
• Lack of make-up air. Refer to Exhaust
Requirements section.
• Obstruction in the exhaust duct. Refer to
Exhaust Requirements section.
WARNING
Do not operate tumbler if airflow switch is
faulty. An explosive gas mixture could
collect in tumbler if airflow switch does not
operate properly.
1
W407
Prepurge
Time
Trial for
Ignition
To Reset
Lockout
Models Location
(seconds) (seconds) Condition:
Press lighted
CE and
Australia
reset button in
rear contactor
box
18
10
T30
Open loading
door
1-3
1-3
10
10
All others
Open loading
door
TMB2104N
T45
1
Wire Tie
Table 2
Figure 4
4. Turn on electrical supply to tumbler.
5. Open the supply valve for gas or steam heated tumblers.
6. After performing the previous checks, start the
tumbler by pressing START. (Refer to the
Operating Manual for detailed instructions.)
Release the start button and open the loading
door. The cylinder should stop rotating within
seven seconds after the door is opened a
maximum of 2 inches (51 mm). If it does not,
adjust the loading door switch. Refer to
Adjustments section.
7. Gas tumblers: Start the tumbler and check the
burner flame. Adjust the air inlet shutter as
required. Refer to Adjustments section.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installing CE Gas Drying Tumblers
WARNING
9. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the
tumbler before servicing.
• Close gas shut-off valve to gas tumbler
before servicing.
• Close steam valve to steam tumbler
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.
W002
General Information
This information is to be used when installing gas
tumblers in countries, and/or on gases, different than
the machine’s factory configuration. Tumblers are
supplied from the factory for operation on Natural Gas
1000 Btu/cu ft. (8914 kcal/m3), or L.P. Gas 2500 Btu/
cu ft. (22,250 kcal/m3) in the countries of GB/IE/PT/
ES/IT/GR/LU/CH. To install machines in any other
country, or on any other gas, requires some level of
modification.
T452I
Figure 5
If the tumbler does not meet ANY of the listed
requirements, remove tumbler from use. Refer to
Removing Tumbler from Service section
Required for CE Models Only
Once machine is installed, please be sure to complete
the following items:
Burner orifices, stickers, block-open kits, regulator
springs and other parts needed for conversions are to
be ordered separately.
• Review and verify machine operation with
customer.
Models are built in two different configurations:
• Leave all literature and a signed Declaration of
• Regulated Natural Gas – Burner orifice is sized
for Natural Gas, second family, group H (E) at
20 mbar inlet pressure. Regulator/governor is
operational. Gas valve CAN be field-converted to
a non-regulating type.
Conformity with customer.
• Review machine warranty information with
customer.
• Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).
• Unregulated L.P. (Liquefied Petroleum) Gas –
Burner orifice is sized for L.P., third family,
group 3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CANNOT
be field-converted to a regulating type.
Serial plates supplied from the factory are configured
for the countries of GB/IE/PT/ES/IT/GR/LU/CH.
These instructions pertain to the situations when the
country of use or gas supply is different than that on
the serial plate.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
19
Installation
Table 3 describes the different gases that are available
in different CE countries, and how the machines need
to be configured to operate with those gases. In the
CE, there are Natural Gas configurations that do not
allow for machine regulation, and L.P. Gas
configurations that must be regulated. For L.P. Gas,
third family B/P at 50 mbar, order regulated Natural
Gas machines and convert according to Table 3.
WARNING
When converting the tumbler to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumbler) that will maintain the gas supply
at the inlet pressure specified.
W430
Basic Configuration
1. Determine the necessary conversion operations to
convert from the factory-supplied configuration
to the desired configuration.
2. Perform the conversions required so the machine
is properly configured for the desired country and
gas (refer to Specific Conversion Procedures
section):
SPECIFIED
LOCAL INLET
PRESSURE
•
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but unregulated tumblers were needed, or
if the gas supply type is changed at a later date.
2
3
1
•
•
•
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
T103K
How to Change Regulator Spring, DE/AT
Only
1
2
3
Gas Shut-Off Valve (Ahead of pressure tap)
Pressure Tap
Gas Shut-Off Valve (Shown in closed position)
3. If applicable, peel off the appropriate country
sticker (included with machine) and apply it to
the serial plate over the existing country
information.
Figure 6
4. If applicable, peel off the appropriate conversion
sticker (included with machine) and apply it to
the data plate over the “ADJUSTED FOR ______
GAS: ______” information.
5. Commission tumbler for use.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Gases and Configurations
Burner
Orifice
Pressure,
mbar
Supply
Group Pressure,
mbar
Burner
Orifice
Part No.
Country
Code
Capacity/ Diameter,
Gas Type
Quantity
Model
mm
Natural Gas
L.P. Gas
H
B/P
E
20
30
8.0
T30
T45
4.0
4.6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
M402992
M411371
DK/NO/
SE/FI/CZ/
EE/LV/LT/
SI/SK
No Governor
8.0
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
20
T30
T45
4.0
4.6
M402992
M411371
DE
NL
LL
L
30
No Governor
11.0
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
25
T30
T45
4.0
4.6
M402992
M411371
B/P
E+
+
30
No Governor
No Governor
No Governor
8.0
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
20 or 25
28 or 37
20
T30
T45
3.3
3.7
M401021
M401000
BE/FR*
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
H
T30
T45
4.0
4.6
M402992
M411371
GB/IE/PT/
ES/IT/GR/
LU/CH
+
28 or 37
20
No Governor
8.0
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
H
T30
T45
4.0
4.6
M402992
M411371
AT
CY/IS/MT
HU
B/P
B/P
H
30
No Governor
No Governor
8.0
T30
T45
2.2
2.5
M401011
M401007
L.P. Gas
30
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
25
T30
T45
4.0
4.6
M402992
M411371
B/P
H
30
No Governor
8.0
T30
T45
2.2
2.5
M401011
M401007
Natural Gas
L.P. Gas
20
T30
T45
4.0
4.6
M402992
M411371
PL
3P
37
No Governor
T30
T45
2.2
2.5
M401011
M401007
Burner orifice information at 0-2000 feet (0-600 meters)
altitude.
*
For Natural Gas, Group E+ applications, convert
using L.P. Gas model and replace burner orifice(s).
Table 3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
2. Follow instructions in Conversion Kit, Part No.
431485 (Johnson Part No. GM-70 CBP).
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: This kit does not contain any burner
orifices.
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but regulated tumblers were needed.
3. Change burner orifice size as required by the
appropriate table according to How to Change
Burner Orifice Size.
Johnson GM7000 gas valve:
4. Commission tumbler for use.
1. Disconnect electrical power from tumbler. Close
1
10
9
2
8
7
3
6
4
5
TMB2135N
1
2
3
4
Gas Shut-Off Valve Assembly (closed position)
Gas Valve
Burner Orifice
Regulator Adjusting Housing and Gasket
(Regulated version shown)
Gas Valve Bracket
6
7
8
Required Burner Orifice Pressure
Manometer
Hose - Connect Over Loosened Slotted
Pressure Tap Screw in Bottom of Gas Valve
Spud Holder
9
10
5
Outlet Pressure Tap
Figure 7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
How to Change Burner Orifice Size
1. Disconnect electrical power from tumbler. Close
2. For Johnson GM7000 gas valve:
Remove burner orifice(s) from the spud holder.
3. Install the new, correct burner orifices. Refer to
Figure 8. Torque each to 9 – 10 Nm.
4. Commission tumbler for use.
NOTE: Blank burner orifices are available as Part
No. M400995.
How to Adjust Gas Valve Governor/Regulator
1. Check gas burner orifice (manifold) pressure as
2. Loosen screw plug inside pressure tap located on
underside of valve.
3. Connect a “U”- tube manometer (or similar
pressure gauge) to the tap.
4. Start tumbler and note pressure once flame is
burning. Remove regulator cap and adjust
regulator screw until the injector pressure per
applicable table is achieved. Replace regulator
cap and close needle valve (pressure tap).
5. Commission tumbler for use.
1
BURNER
ORIFICE
TMB2015N
1
Size Stamped on Burner Orifice
Figure 8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
23
Exhaust Requirements
Venting
WARNING
For maximum efficiency and minimum lint
accumulation, tumbler air must be exhausted to the
outdoors by the shortest possible route.
A drying tumbler produces combustible
lint. To reduce the risk of fire, the tumbler
must be exhausted to the outdoors.
Proper sized exhaust ducts are essential for proper
operation. All elbows should be sweep type. Exhaust
ducts must be assembled so the interior surfaces are
smooth, so the joints do not permit the accumulation
of lint. DO NOT use plastic or thin foil flexible ducts.
Use exhaust ducts made of sheet metal or other non-
combustible material. Use duct tape or pop-rivets on
all seams and joints.
W057
To reduce the risk of fire and
accumulation of combustible gases, DO
NOT exhaust tumbler air into a window
well, gas vent, chimney or enclosed,
unventilated area such as an attic wall,
ceiling, crawl space under a building, or
concealed space of a building.
W059
Verify that old ducts are thoroughly cleaned out before
installing new tumbler(s).
Layout
Whenever possible, install tumblers along an outside
wall where duct length can be kept to a minimum, and
make-up air can be easily accessed. Elbows and long
vents tend to increase drying time. Construction must
not block the airflow at the rear of the tumbler. Doing
so would prevent adequate air supply to the tumbler’s
combustion chamber.
WARNING
Improperly sized or assembled ductwork
causes excess back pressure which
results in slow drying, lint collecting in
the duct, lint blowing back into the room,
and increased fire hazard.
W355
Make-Up Air
NOTE: Exhaust ducts must be constructed of sheet
metal or other noncombustible material. Such
ducts must be equivalent in strength and corrosion
resistance to ducts made of galvanized sheet steel
not less than 0.0195 inches (0.495 mm) thick. Local
codes may require additional thickness.
A tumbler is forced air exhausted and requires provisions
for make-up air to replace air exhausted by the tumbler.
IMPORTANT: Do not obstruct the flow of
combustion and ventilation air.
Make-up air openings should be as close to the
tumbler(s) as possible.
Where the exhaust duct pierces a combustible wall or
ceiling the opening must be sized per local codes. The
space around the duct may be sealed with
The required make-up air opening to the outside for
each tumbler (includes both pockets) is:
220 square inches (1418 sq. cm) for T30 models
288 square inches (1856 sq. cm) for T45 models
IMPORTANT: For best performance provide an
individual exhaust duct for each tumbler. Do not
install a hot water heater in a room containing
tumblers. It is better to have the water heater in a
separate room with a separate air inlet.
Make-up air openings with louvers will restrict
airflow. The opening must be increased to compensate
for area taken up by louvers.
Make-up air openings for a room containing
tumbler(s) and/or gas fired hot water heater or other
gravity vented appliances must be increased
sufficiently to prevent downdrafts in any of the vents
when all tumblers are in operation. Do not locate
gravity vented appliances in the same room as
tumblers. If it is necessary to duct make-up air to the
tumbler(s), increase the area of the ductwork by 25%
to compensate for any restriction in air movement.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
24
Exhaust Requirements
Individual Venting
Duct
Diameter
Equivalent Length of
Straight Duct
For maximum efficiency and performance, it is preferred
to exhaust tumbler(s) individually to the outdoors.
10 in. (254 mm)
12 in. (305 mm)
14 in. (355.6 mm)
16 in. (406.4 mm)
18 in. (457.2 mm)
One 90° elbow = 11.6 ft. (3.5 m)
One 90° elbow = 14 ft. (4.3 m)
One 90° elbow = 16 ft. (4.9 m)
One 90° elbow = 18.7 ft. (5.7 m)
One 90° elbow = 21 ft. (6.4 m)
IMPORTANT: At no point may the cross sectional
area of installed venting be less than the cross
sectional area of the exhaust outlet of the tumbler.
The exhaust duct must be designed so the static back
pressure measured 12 inches (305 mm) from the
exhaust outlet does not exceed the maximum
allowable pressure specified on the installation sticker
on the rear of the tumbler.
Equivalent Length (feet) = 1.17 x Duct Diameter (inches)
Table 4
Example: A 12 inch (305 mm) diameter duct’s
equivalent length of 14 feet (4.3 m) of duct and two
90° elbows is:
NOTE: Static back pressure must be measured
with both pockets running.
Equivalent Length = 14 feet + (2) 90° elbows
= 14 feet + 14 feet + 14 feet
The maximum allowable length venting of the same
diameter as the exhaust thimble is 14 feet (4.3 m) and
two 90° elbows or equivalent. If the equivalent length
of a duct required for an installation exceeds the maximum
allowable equivalent length, the diameter of a round duct
must be increased by 10% for each additional 20 feet
(6.1 m). Cross section area of a rectangular duct must
be increased by 20% for each additional 20 feet (6.1 m).
= 42 feet (12.8 m)
With the tumbler in operation, and both pockets
running, airflow at any point in the duct should be at
least 1200 feet per minute (366 meters per meter) to
ensure that lint remains airborne. If 1200 feet per
minute cannot be maintained, schedule monthly
inspections and cleaning of the ductwork.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
25
Exhaust Requirements
3
4
2
1
5
TMB2103N
1
2
3
4
5
Removable strip of panel in framing wall to permit removal of tumbler from framing wall
Partition or bulkhead
Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm)
2 in. (51 mm) minimum clearance on both sides of duct
Exhaust airflow – maximum length of duct: 14 ft. (4.3 m)
Figure 9
NOTE: Do not install wire mesh or screen in
exhaust duct opening to avoid lint build-up or
impacting proper discharge of air from tumblers.
NOTE: Where exhaust duct pierces a combustible
wall or ceiling, the opening must be sized per local
codes.
NOTE: Inside of duct must be smooth. Do not use
sheet metal screws to join sections.
Consult your local building code for regulations which
may also apply.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
26
Exhaust Requirements
NOTE: Never connect a tumbler duct at a 90° angle
will cause excessive back pressure, resulting in poor
performance. Never connect two tumbler exhaust
ducts directly across from each other at the point of
entry to the collector duct.
Manifold Venting
While it is preferable to exhaust tumblers individually
to the outdoors, a main collector duct may be used if it
indicates minimum diameters, and should be increased
if the collector length exceeds 14 feet (4.3 m) and two
90° elbows. The diameter of a round duct must be
increased by 10% for each additional 20 feet (6.1 m).
Cross sectional area of a rectangular or square duct must
be increased 20% for each additional 20 feet (6.1 m).
sizing. The collector duct may be rectangular or square
in cross section, as long as the area is not reduced.
Provisions MUST be made for lint removal and
cleaning of the collector duct.
With the tumbler in operation, and both pockets
running, airflow at any point in the duct should be at
least 1200 feet per minute (366 meters per meter) to
ensure that lint remains airborne. If 1200 feet per
minute cannot be maintained, schedule monthly
inspections and cleaning of the ductwork.
The vent collector system must be designed so the
static back pressure measured 12 inches (305 mm)
from the exhaust outlet does not exceed the maximum
allowable pressure specified on the installation sticker
on the rear of tumbler. Static back pressure must be
measured with all tumblers vented into the collector
operating.
T438I
Figure 10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
27
Exhaust Requirements
1
2A
L
K
J
I
H
G
F
D
C
B
A
E
3
ONE BATTERY SAME AS LARGEST STATION USED
TMB2019N
1
2B
L
L
K
J
I
J
K
I
CONTINUE
TO A
CONTINUE
TO A
3
TWO BATTERIES
TMB2018N
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening
MUST be sized per local codes.
2A
2B
3
Outlet Duct Diameter for One Battery
Outlet Duct Diameter for Two Batteries
45° Typical
Figure 11
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Exhaust Requirements
T45
T30
Duct Station
8 in. (203 mm) Duct
10 in. (254 mm) Duct
2A
2B
2A
2B
9 in. (229 mm)
12 in. (305 mm)
15 in. (381 mm)
17 in. (432 mm)
19 in. (483 mm)
21 in. (533 mm)
23 in. (584 mm)
24 in. (610 mm)
26 in. (660 mm)
27 in. (686 mm)
28 in. (711 mm)
30 in. (762 mm)
12 in. (305 mm)
17 in. (432 mm)
22 in. (559 mm)
25 in. (635 mm)
27 in. (686 mm)
30 in. (762 mm)
33 in. (838 mm)
34 in. (864 mm)
37 in. (940 mm)
39 in. (991 mm)
40 in. (1016 mm)
43 in. (1092 mm)
10 in. (254 mm)
15 in. (381 mm)
18 in. (457 mm)
21 in. (533 mm)
24 in. (610 mm)
26 in. (660 mm)
28 in. (711 mm)
30 in. (762 mm)
32 in. (813 mm)
33 in. (838 mm)
35 in. (889 mm)
36 in. (914 mm)
15 in. (381 mm)
22 in. (559 mm)
26 in. (660 mm)
30 in. (762 mm)
34 in. (864 mm)
37 in. (940 mm)
40 in. (1016 mm)
43 in. (1092 mm)
46 in. (1168 mm)
47 in. (1194 mm)
50 in. (1270 mm)
51 in. (1295 mm)
A
B
C
D
E
F
G
H
I
J
K
L
Table 5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Requirements
The following must be furnished and installed by the
customer for the gas service line to each tumbler.
WARNING
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLER IF THE GAS SERVICE IS NOT
THE SAME AS THAT SPECIFIED ON THE
TUMBLER SERIAL PLATE! It will first be
necessary to convert the gas burner
orifice and gas valve. Appropriate
• Sediment traps
• Shut-off valves
• Supply pressure taps
It is important that equal pressure be maintained at all
tumbler gas connections. This can best be done by
installing a one inch (25 mm) pipe gas loop. Refer to
conversion kits are available.
W060
IMPORTANT: Any product revisions or conversions
must be made by the Manufacturer’s Authorized
Dealers, Distributors or local service personnel.
WARNING
To reduce the risk of fire or explosion, if
the tumbler is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the
room where the tumbler is installed.
IMPORTANT: The tumbler must be isolated from
the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressure equal to or less than 0.5 psig
(3.45 kPa, 34.5 mbar).
W062
NATURAL GAS line pressure must be maintained at
6.5 water column inches (1.62 kPa) with no less than 5
water column inches (1.24 kPa) and no more than 10.5
water column inches (2.61 kPa), with all gas
appliances running (tumblers, water heaters, space
heaters, furnace, etc.). An in-line pressure regulator
may be required if the line pressure exceeds 8 water
column inches (2.0 kPa) with all gas appliances
running.
IMPORTANT: The tumbler and its manually
operated appliance gas valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of 0.5 psi (3.45 kPa, 34.5 mbar).
IMPORTANT: The installation must comply with
local codes or, in the absence of local codes:
LIQUID PETROLEUM GAS (L.P.) line pressure must
be maintained at 11 water column inches (2.74 kPa),
with no less than 10 water column inches (2.49 kPa)
and no more than 13 water column inches (3.23 kPa),
with all gas appliances running (tumblers, water
heaters, space heaters, furnace, etc.).
• with the latest edition of the “National Fuel
Gas Code,” ANSI Z223.1/NFPA 54 in the
U.S.A.,
• with CSA-B149.1 or Natural Gas and Propane
Installation Code in Canada,
• and Australian Gas Association/Australian
L.P. Gas Association requirements in
Australia.
For converting Non-CE models from Natural Gas to
L. P. Gas:
T30 – M4707P3
T45 – M4880P3
Obtain specific gas service pipe size from the gas
CE GASES refers to Installing CE Gas Drying
Tumblers sections, the above data does not apply to
the CE.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
30
Gas Requirements
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive leak
detection fluid. Purge air in gas service line by
operating the tumblers in the drying mode. If burner
does not light and unit goes into lockout, open and
close the door and restart. Repeat these steps until
burner ignites. Use pipe compound, resistant to
actions of L.P. gas, on all pipe threads.
2
3
1
4
5
8
7
WARNING
Check all pipe connections, internal and
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
6
TMB2007N
1
Gas Line to Tumbler
Shut-Off Valve
Gas Supply Piping System
Gas “T” Fitting
2
3
4
5
6
7
8
checked twice a year for leakage.
W635
6 in. (152 mm) Minimum Gas Pipe
Gas Pipe Cap
Sediment Trap
Supply Pressure Tap
Figure 12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Requirements
Gas Supply Pipe Sizing and Looping
1
3
2
12
11
9
10
1
2
3
4
5
6
7
8
9
4
M
5
8
6
7
TMB2126N
1
2
3
4
Gas Furnace (120,000 Btu/hr.)
8
9
10
11
12
25 ft. (7.6 m)
Main Regulator
Gas Meter
Pressure Regulator (if required)
T30 Tumblers (73,000 Btu/hr per pocket;
146,000 total Btu/hr for machine)
Gas Water Heaters (400,000 Btu/hr. each)
Gas Space Heaters (70,000 Btu/hr. each)
Sediment Traps, Supply Pressure Taps and
1 in. (25.4 mm) Gas Pipe Loop
5
6
7
19 ft. (5.8 m)
Minimum Pipe Size is 0.5 in. (12.7 mm)
T45 Tumblers (95,000 Btu/hr per pocket;
190,000 total Btu/hr for machine)
SAMPLE CALCULATIONS:
Equivalent length = Total length of main gas supply pipe to the far end of the tumblers.
= 25 ft. + 19 ft. (7.6 m + 5.8 m) gas supply pipe
= 44 ft. (13.4 m) Total Gas Line
Total Btu/hr.
= The sum of the Btu/hr. of all T30 tumblers being fed by the main gas supply pipe.
= 9 x 73,000
= 657,000 Btu/hr.
IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers
connected to single gas service. Other gas using appliances should be connected upstream from loop.
Figure 13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Requirements
Gas Pipe Size Required for 1000 Btu Natural Gas — 0.64 Specific Gravity
at 7 ± 1.5 inches (17.4 ± 4 mbar, 1.74 ± 0.37 kPa) Water Column Pressure
Equivalent Length
25 feet
(7.63 m)
50 feet
75 feet
100 feet
125 feet
150 feet
(45.75 m)
Gas
Appliances
Total Btu/hr
(15.25 m)
(22.88 m)
(30.50 m)
(38.13 m)
Based on 0.3 in. Water Column Pressure Drop for Length Given
Sizes shown in inches (mm)
100,000
120,000
140,000
160,000
180,000
200,000
300,000
400,000
500,000
600,000
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
1,300,000
1,400,000
1,500,000
1,600,000
1,700,000
1,800,000
1,900,000
2,000,000
2,200,000
2,400,000
2,600,000
2,800,000
3,000,000
0.75 (19.05)
0.75 (19.05)
0.75 (19.05)
0.75 (19.05)
1 (25.40)
0.75 (19.05)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3.5 (88.90)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
1 (25.40)
1 (25.40)
1 (25.40)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
1.25 (31.75)
1.25 (31.75)
1.5 (38.10)
1.5 (38.10)
1.5 (38.10)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
2 (50.80)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
2.5 (63.50)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
4 (101.60)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
3.5 (88.90)
For L.P. Gas, correct the total Btu/hr by multiplying it by 0.6. The answer is the equivalent Btu on the
above chart.
The installation must conform with local codes or, in the absence of local codes:
• with the latest edition of the “National Fuel Gas Code,” ANSI Z223.1/NFPA 54 in the U.S.A.,
• with CSA-B149.1 or Natural Gas and Propane Installation Code in Canada,
• and Australian Gas Association/Australian L.P. Gas Association requirements in Australia.
Table 6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Requirements
High Altitude Burner Orifice Sizing
For proper operation at altitudes above 2000 feet
(610 meters), the gas burner orifice size must be
reduced to ensure complete combustion. Refer to
For CE models, consult local gas supplier.
Altitude
Burner Orifice
New Rate
(Btu/hr.)*
Model
T30
Gas
Part
Number
Feet
Meters
No. Inches mm Quantity
Natural Gas 2001-4000
4001-6000
610-1220
1221-1830
1831-2440
2441-3050
610-1830
22
24
26
28
42
43
44
15
17
18
20
36
37
38
40
0.1570
0.1520
0.1470
0.1405
0.0935
0.0890
0.0860
0.1800
0.1730
0.1695
0.1610
0.1065
0.1040
0.1015
0.0980
4.0
3.9
3.7
3.6
2.4
2.3
2.2
4.6
4.4
4.3
4.1
2.7
2.6
2.6
2.5
M402996
M402980
M401000
M401014
M403017
M406184
M401011
M411511
M411374
M402988
M401002
M402487
M411375
M411376
M406361
134,320
122,640
110,960
99,280
6001-8000
8001-10,000
2
L.P. Gas
2001-6000
6001-8000
8001-10,000
134,320
110,960
99,280
1831-2440
2441-3050
610 – 1220
Natural Gas 2001 – 4000
183,000
168,400
155,000
142,600
183,000
168,400
155,000
142,600
T45
4001 – 6000 1221 – 1830
6001 – 8000 1831 – 2440
8001 – 10000 2441 – 3050
2
L.P. Gas
2001 – 4000
610 – 1220
4001 – 6000 1221 – 1830
6001 – 8000 1831 – 2440
8001 – 10000 2441 – 3050
* Btu/hr. derate of 4% per 1000 feet (305 meters) of altitude.
Table 7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
This tumbler must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This tumbler must be
connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the
tumbler before servicing.
• Close gas shut-off valve to gas tumbler
before servicing.
• Metal conduit and/or BX cable is not considered
• Close steam valve to steam tumbler
before servicing.
ground.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
• Connecting the Neutral from the electrical
service box to the tumbler ground screw does not
constitute a ground.
• A dedicated ground conduit (wire) must be
connected between the electrical service box
ground bar and tumbler ground screw.
tumbler is properly grounded.
W002
WARNING
To reduce the risk of electrical shock,
de-energize the electrical circuit being
connected to the tumbler before making
any electrical connections. All electrical
connections should be made by a
qualified electrician. Never attempt to
connect a live circuit.
W409
machine, if there is a “High Leg” or
“Stinger Leg” it should be connected to
CAUTION
L3.
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
W069
Grounding Instructions
servicing.
NOTE: To ensure protection against shock, this
tumbler MUST be electrically grounded in
accordance with the local codes, or in the absence
of local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, or local codes.
W071
For CE Models Only
All manually operated models are factory-equipped
with an emergency stop button on the front panel. If
the emergency stop function is desired on coin-
operated models, an external emergency stop button
may be installed as specified on the machine wiring
diagram.
NOTE: Activation of the emergency stop button
stops all machine control circuit functions, but
DOES NOT remove all electrical power from
machine.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
35
Electrical Requirements
Service/Ground Location
Model
Heat Source
Ground and Terminal Block Locations
Terminal Block
Ground Screw
5
4
3
2
1
70219001R2
SECURE GROUND
WIRETO
GROUND SCREW
T30/T45
Non-CE
Gas or Steam
TMB2041N
Ground Lug
SECURE GROUND
WIRE TO
GROUND SCREW
L1 L 2 L
1L1
13 NO 21 NC A1
LC1D32
13 NO 21 NC A1
LC1D32
POWER
DISTRIBUTION
BLOCK
Power Distribution
Block
14 NO 22 NC A2
14 NO 22 NC A2
2T1
4T2
6T3
2T1
4T2
6T3
T30
Non-CE
Electric
TMB2113N
Power
POWER DISCONNECT
Disconnect
A
B
1
1
2
3
4
5
6
7
8
CIRCUIT DIAGRAM
SECURE GROUND
WIRE TO
GROUND SCREW
GROUN
T30
CE
Gas or Steam
Ground Screw
TMB2114N
L1 L 2 L 3
PE
M412096
GROUND
LUG
Power Distribution
Block
L1
POWER
DISTRIBUTION
BLOCK
1
13 NO 21 NC A1
LC1D32
14 NO 22 NC A2
2T1
4T2
6T3
T30
CE
Ground Lug
Electric
TMB2115N
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
If tumbler requires conversion for use on another
service voltage, complete the steps detailed in the
Conversion Instructions section prior to connecting
service to machine.
Connecting Electrical Service
The following steps outline the procedure for
connecting electrical service to the tumbler.
• 3 Phase models – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of
“single phasing” and causing premature
failure of the motor(s).
If tumbler does not require conversion or has been
converted according to the Conversion Instructions
section of this manual, continue with step 1.
NOTE: The wiring diagram is located in the upper
junction box or upper contactor box.
• Electrical service must be connected using the
appropriate permanent rigid metal conduit
system.
1. For new service, install a circuit breaker or fused
disconnect of proper voltage and current rating as
close to each tumbler as possible.
• Service conductors must be copper only.
2. Route service conduit from circuit breaker panel
or disconnect panel to tumbler service connection
box. Conduit routing should not obstruct access
for maintenance or servicing. Refer to Service/
Ground Location.
For an existing service, determine your service voltage
and conductor amperage. Carefully review the tumbler
serial plate ratings and Electrical Requirements
section of this manual. If service is inadequate it must
be upgraded by a qualified electrical contractor. Never
connect an improper or inadequate service to any
machine.
3. Pull conductors through conduit and attach to
circuit breaker and ground connection. Secure
service ground wire to the grounding screw or
lug. Attach service conductors to appropriately
labeled positions on the terminal block. Make
sure all connections are secure.
Configuring Your Tumbler for Other
Service Voltages
Several gas and steam tumbler models have been
designed to be field convertible to other service
4. Check electrical service phase sequence (3 Phase
models only) as follows:
a. Energize the electrical service and
Your tumbler can be
If your Serial Plate
momentarily start the tumbler. Check the
direction of cylinder rotation. If the cylinder
rotates clockwise as viewed from the front,
the phase sequence is correct. If the cylinder
rotates counterclockwise, proceed with step b.
Models
converted to the
voltage is:
following voltages:
120 Volt/60 Hertz/
1 Phase
208-240 Volt/60 Hertz/
1 Phase
T30
T30
T30
b. Disconnect power to machine, disconnect and
reverse the L1 and L2 connections on the
terminal block.
200-220 Volt/60 Hertz/
1 Phase
100 Volt/60 Hertz/
1 Phase
200 Volt/50 Hertz/
1 Phase
100 Volt/50 Hertz/
l Phase
Electrical Connections
All gas and steam tumblers require a single service
connection to TB1 of the upper unit junction box only.
The serial plate reflects current draw, breaker/fuse size
and conductor amperage required for the entire
machine.
240 Volt/60 Hertz/
3 Phase
200-208 Volt/60 Hertz/
3 Phase
T30/
T45
380 Volt/50 Hertz/
3 Phase
400-415 Volt/50 Hertz/
3 Phase
T30
Table 8
All electric tumblers require separate service
connections for each upper and lower unit. Serial Plate
ratings reflect current draw, breaker/fuse size and
conductor amperage required per unit.
NOTE: Electric models are not field convertible
and must be connected to service specified on serial
plate.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
37
Electrical Requirements
Conversion Instructions
If serial plate voltage is:
Tumbler can be converted to the following voltages:
120 Volt/60 Hertz/
1 Phase
208-240 Volt/60 Hertz/1 Phase Models:
3W&G
2W&G
1. Prior to connecting service, locate the black/red wire which runs between
terminal block and the motor relay or contactor. Refer to figure below.
(T30 Models Only)
120 V~ LOCATION
(AS RECEIVED)
L1
208 or 240 V~
LOCATION
(AS CONVERTED)
120 V-
120 V-
208 OR
240 V-
L2
L3
TO MOTOR RELAY
OR CONTACTOR
BLK/RED
TERMINAL BLOCK
T381I
2. Disconnect the black/red lead from L1 of the terminal block and connect to
L2 of the terminal block. Repeat steps 1 and 2 for upper and lower junction
box areas.
3. Sign and date conversion sticker located on back of tumbler.
4. Follow the instructions covered in Connecting Electrical Service section.
240 Volt/60 Hertz/
3 Phase
200-208 Volt/60 Hertz/3 Phase Models:
3W&G
3W&G
1. Prior to connecting electric service, locate transformer configuration jumper
in junction box area.
2. Remove the 240 Volt jumper and replace it with the 208 Volt jumper located
in the literature packet in cylinder.
3. Repeat steps 1 and 2 for each upper and lower unit.
4. Sign and date conversion sticker located on back of tumbler.
5. Follow the instructions covered in Connecting Electrical Service section.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
If serial plate voltage is:
Tumbler can be converted to the following voltages:
200-220 Volt/60 Hertz/
1 Phase
100 Volt/60 Hertz/1 Phase INTERNATIONAL Models:
2W&G
2W&G
100 Volt/50 Hertz/1 Phase INTERNATIONAL Models:
2W&G
200 Volt/50 Hertz/
1 Phase
1. Prior to connecting electric service, locate transformer configuration jumper
in junction box area.
2W&G
2. Remove the 208 Volt jumper and replace it with the 100 Volt jumper located
in the literature packet from cylinder.
(T30 Models Only)
3. Remove small access cover from back of the fan motor. Locate the two
internal jumper wires, brown and blue connected to motor terminals #6 and
#2. Move brown wire from terminal #6 to terminal #2 and blue wire from
terminal #2 to terminal #4. Be careful not to confuse light blue motor harness
wire with the dark blue internal jumper.
4. Carefully check motor wire connections with wiring diagram and verify that
the motors are configured for low voltage operation before replacing covers.
5. Repeat steps 1 through 4 for each upper and lower unit.
6. Sign and date conversion sticker located on back of tumbler.
7. Follow the instructions covered in Connecting Electrical Service section.
380 Volt/50 Hertz/
3 Phase
400-415 Volt/50 Hertz/3 Phase Models:
3W&G
3W&G
1. Prior to connecting electric service, locate transformer configuration jumper
in junction box area.
(T30 Models Only)
2. Remove the 380 Volt jumper and replace it with the 415 Volt jumper located
in the literature packet from cylinder.
3. Repeat steps 1 and 2 for each upper and lower unit.
4. Sign and date conversion sticker located on back of tumbler.
5. Follow the instructions covered in Connecting Electrical Service section.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
Electrical Requirements for Gas and
Steam Models
NOTE: Use copper conductors only.
NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code for 75°C Conductors and
are intended for use as a guideline only. Electrical
connections should be made only by a qualified
electrical contractor in accordance with all
applicable local and national requirements.
NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
For T30 Gas and Steam Models
(For Total Machine):
Recommended
Fuse or
Breaker Rating
(Amps)
Recommended
Minimum
Terminal Block
Connections
Required
Serial Plate
Voltage
Current
(Amps)
Breaker
Poles
Conductor Size
2
[AWG (mm )]
L1, Neutral,
and ground
16.0
20
1
2
1
1
1
1
1
3
3
3
3
3
3
3
12 (3.31)
14 (2.08)
10 (5.26)
14 (2.08)
8 (8.37)
120V/60 Hz/1ph
L1, L2, Neutral,
and ground
8.0
22.0
11.6
24.2
15.0
15.0
6.4
10
208-240V/60Hz/
1ph
L1, Neutral,
and ground
30
100V/60Hz/1ph
L1, Neutral,
and ground
15
200-220V/60Hz/
1ph
L1, Neutral,
and ground
35
100V/50Hz/1ph
200V/50Hz/1ph
L1, Neutral,
and ground
20
12 (3.31)
12 (3.31)
14 (2.08)
14 (2.08)
14 (2.08)
14 (2.08)
14 (2.08)
14 (2.08)
14 (2.08)
L1, Neutral,
and ground
20
230-240V/50Hz/
1ph
L1, L2, L3,
and ground
10*
10*
10*
10*
10*
10*
10*
200-208V/60Hz/
3ph
L1, L2, L3,
and ground
6.4
240V/60Hz/3ph
200V/50Hz/3ph
L1, L2, L3,
and ground
5.8
L1, L2, L3,
and ground
7.0
230-240V/50Hz/
3ph
L1, L2, L3,
and ground
3.0
380V/50 or 60Hz/
3ph
L1, L2, L3,
and ground
3.2
400-415V/50Hz/
3ph
L1, L2, L3,
and ground
3.3
460-480V/60Hz/
3ph
*
3 Phase machines should not have fuses, breakers only.
Table 9
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
Recommended
For T45 Gas Models (For Total Machine):
Terminal Block
Recommended Fuse
or Breaker Rating
(Amps)
Serial Plate
Connections
Voltage
Current
(Amps)
Breaker
Minimum
Poles Conductor Size
Required
2
(AWG [mm ])
L1, L2, Neutral and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
12.0
9.6
15
15
15
2
3
3
14 (2.08)
14 (2.08)
14 (2.08)
208–240V/60Hz/
1ph
200–208V/60Hz/
3ph
9.6
240V/60Hz/3ph
Table 10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
Electrical Requirements for Electric
Models
NOTE: Connect to individual branch circuit.
NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code for 75°C Conductors and
are intended for use as a guideline only. Electrical
connections should be made only by a qualified
electrical contractor in accordance with all
applicable local and national requirements.
NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
For 21 kW T30 Electric Models:
Recommended
Recommended
Terminal Block
Connections
Required
Serial Plate
Voltage
Current
(Amps)
Breaker
Poles
Minimum
Breaker Rating
(Amps)
Conductor Size
2
[AWG (mm )]
L1, L2, L3,
and ground
62**
80
80
70
70
45
40
35
3
3
3
3
3
3
3
4 (21.2)
4 (21.2)
4 (21.2)
4 (21.2)
8 (8.37)
8 (8.37)
8 (8.37)
200-208V/60Hz/3ph*
200V/50Hz/3ph*
L1, L2, L3,
and ground
60**
55**
54**
33**
31**
27**
L1, L2, L3,
and ground
230-240V/50Hz/3ph*
240V/60Hz/3ph*
L1, L2, L3,
and ground
L1, L2, L3,
and ground
380V/50 or 60Hz/3ph*
400-415V/50Hz/3ph*
460-480V/60Hz/3ph*
L1, L2, L3,
and ground
L1, L2, L3,
and ground
*
These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only.
** Per heater on T30 electric models, each has two heaters.
Table 11
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Steam Requirements
NOTE: Machines require a constant 80 to 100 psig
NOTE: To prevent water hammering, route return
lines below outlets of steam coils.
(5.62 to 7.03 kg/sq. cm) steam service for optimum
operation. The maximum allowable steam pressure
for use with 60 Hertz or 50 Hertz tumblers is
125 psig (8.6 bar). In no case may the pressure
exceed the above value.
Piping Recommendations
• Trap each steam coil individually. Always keep
the trap clean and in good working condition.
Obtain specific steam service pipe sizes from the
steam system supplier or a qualified steam fitter.
• When tumbler is on the end of a line of
equipment, extend header at least 4 feet
(1.2 meters) beyond tumbler. Install shut-off
valve, union, check valve and bypass trap at end
of line. If gravity return to boiler, omit trap.
configurations.
• To prevent condensate draining from headers to
tumbler, piping should have a minimum 12 inch
(305 mm) rise above respective header. Do not
make steam connection to header with a
• Insulate steam supply and return line for safety of
operator and safety while servicing tumbler.
• Keep tumbler in good working condition. Repair
horizontal or downward facing tee or elbow.
or replace any worn or defective parts.
• Whenever possible, horizontal runs of steam
lines must drain, by gravity, to respective steam
header. Water pockets, or an improperly drained
steam header, will provide wet steam, causing
improper operation of tumbler. If pockets or
improper drainage cannot be eliminated, install a
bypass trap to drain condensate from the low
point in the steam header to the return.
WARNING
All system components must have a
125 psig (8.6 bar) working pressure.
Shut-off valves must be installed upstream
of the steam solenoid valve and
downstream of each steam trap so
components can be isolated for
• In both steam supply and steam return line, it is
recommended that each have a pipe union and
shut-off valve. This will enable you to disconnect
the steam connections and service the tumbler
while your laundry facility is in operation.
maintenance or emergency purposes.
All components (solenoid valve, traps)
must be supported to minimize loads on
the tumbler steam coil connections.
W480R2
• Connect the steam solenoid valve to the related
steam coil inlet connection with nipples, flex
hoses, unions and tee.
• Strainers may require cleaning due to materials
from hoses or pipes.
• Install vacuum breaker (optional), bucket trap
with built-in strainer and check valve. For
successful operation of tumbler, install trap 18
inches (457 mm) below coil and as near to the
tumbler as possible. Inspect trap carefully for
inlet and outlet markings and install according to
trap manufacturer’s instructions. If steam is
gravity returned to boiler, omit trap but install
optional vacuum breaker and check valve in
return line near tumbler. Gravity return requires
entire return plumbing be below steam coil
outlet.
• Install union and shut-off valve in return line and
make final pipe connections to return header.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
43
Steam Requirements
Installing Steam Trap and Making
Condensate Return Connections
WARNING
The flexible steam hoses connecting the
coil outlet connections and steam traps
must have a minimum of 125 psig
(pounds per square inch gauge) (8.79 kg/
sq. cm.) working pressure. A shut-off
valve must be installed downstream from
each steam trap so the condensate return
line can be isolated in event a steam trap
requires maintenance.
The steam trap must be installed and the coil outlet
connections must be connected to the condensate
return lines. The following steps outline the procedure
for installing the steam trap and connecting the
installations.
1. Use flexible lines between steam inlet solenoid
and steam coils, as well as outlet between steam
coil and traps.
Each steam trap must be supported so
minimum load is exerted on the coil outlet
2. If necessary, install a strainer at the end of each
flexible hose.
connection.
W066
3. Install a steam trap to each strainer.
IMPORTANT: Steam trap must be installed a
minimum of 18 inches (457 mm) below the steam
coil outlet connections.
4. Install a shut-off valve to each steam trap.
5. Connect to the condensate return lines.
6. For steam solenoid valve wiring connections,
refer to Wiring Diagram supplied with tumbler.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
44
Steam Requirements
SUPPLY
2
1
4
9
3
10
5
6
4
8
RETURN
7
6
5
10
T473I
NOTE: Refer to Table 12 for sizing of steam lines. Piping must also be sized accordingly for length of runs,
and number of elbows.
1
2
3
4
5
Steam Coil
6
7
8
9
10
Trap with Built-In Strainer
Vacuum Breaker (Optional)
18 in. (457 mm) Drop
Solenoid Valve (Supplied with machine)
Union
12 in. (305 mm) Riser
Condensate Return Line from Supply Line
Shut-Off Valve
Check Valve
Figure 14
Steam Trap Size*
Model
T30
Steam Pressure PSI (bar) Minimum Pipe Diameter
15-100 (1-6.9) 3/4 in. NPT
(Pounds Condensate/Hour)
110
*Based on 100 psi.
Table 12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Single Drop Timer
NOTE: The following information is for
Setting Dry Time Dipswitches
models with an SD control suffix only.
To change the dry time on the tumbler, combinations
of dipswitches can be set on the control.
Power-Up Mode
There are eight dipswitches on the tumbler control.
The first six switches are used to program the amount
of additional heat time given for each coin pulse. The
additional drying time is added to the factory default
minimum heat time of one minute. A valve of 1 to 64
minutes of additional drying time is available for each
coin drop pulse.
When power is applied to the tumbler, the IN USE
light flashes factory status information. Following this,
the control goes into READY Mode (light off) or RUN
Mode if power was interrupted during a cycle (light
on, time remaining unchanged).
Ready Mode
The last two switches are used to program the amount
of additional cool down time. The additional cool
down time is added to the factory default minimum
cool down time of 1 minute. A value of 1 to 3
additional minutes is available. The control is shipped
from the factory programmed with 1 minute of
minimum heat time, preset with 7 additional minutes
of drying time (dipswitches 1, 2 and 3 in ON position)
and 1 minute of minimum cool down time for a total
time of 9 minutes for a coin pulse. For dipswitch
In READY Mode (light off), the control waits for the
vend to be satisfied. When vend is satisfied the control
goes into START Mode.
Start Mode
In START Mode (light on), the vend has been satisfied
but the start button has not been pressed. Time
remaining in the cycle will not change until the start
button is pressed. When the start button is pressed the
machine goes into RUN Mode.
The control reads the dipswitch settings at power-up.
The control must be powered down to change the
dipswitch settings.
Run Mode
In RUN Mode (light on), the machine is running a
cycle and the time remaining is counting down. When
time remaining counts down to zero, the control goes
into READY Mode.
To change the time for a coin pulse, the desired dry
time dipswitches must be set to ON position. All other
dipswitches must be in OFF position.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
46
Single Drop Timer
Dipswitch Settings
Cool Down
Switch Number
Heat Switch Number
Cool Down Per
Cycle (in Minutes)
Heat Time Per Coin
1
2
3
4
5
6
7
8
Pulse (in Minutes)
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
1
1 (factory default)
2
2
3
4
OFF
ON
OFF
ON
3
ON
ON
4
OFF
ON
OFF
OFF
ON
5
ON
6
OFF
ON
ON
7
ON
ON
8 (factory default)
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
9
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
Table 13 (Continued)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Single Drop Timer
Table 13 (Continued)
Heat Switch Number
Heat Time Per Coin
Pulse (in Minutes)
1
2
3
4
5
6
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
Total Cycle Time = Heat Time + Cool Down Time
Table 13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70304601
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjustments
Loading Door Switch
Airflow Switch
The door switch should be adjusted so the cylinder
stops when door is opened 2 inches (51 mm) plus or
minus 0.25 inch (6 mm). This switch is a normally
open switch and is closed by the hinge cam when the
door is closed. If adjustment is required, refer to
Figure 15 and proceed as follows:
The airflow switch is set at the factory for proper
operation. No adjustment necessary.
The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air, or an
obstruction in the exhaust duct. These should be
checked and the required corrective action taken.
1. Close door and start tumbler, slowly open loading
door. Cylinder and heat system should shut off
when door is open 2 inches (51 mm) plus or
minus 0.25 inch (6 mm).
WARNING
The tumbler must not be operated if the
airflow switch does not operate properly.
Faulty airflow switch operation may cause
an explosive gas mixture to collect in the
2. Slowly close the loading door. When door is
2 inches (51 mm) from being fully closed, the
door switch actuating bracket (located on the
door) should depress the button and the switch
arm with an audible “click.”
tumbler.
W072
3. If the actuating bracket does not operate the
switch at the appropriate door closure, bend the
actuating switch bracket in or out to achieve
proper actuation.
IMPORTANT: Airflow switch vane must remain
closed during operation. If it opens and closes
during the drying cycle, this indicates insufficient
airflow through the tumbler. If switch remains
open, or pops open and closed during the cycle, the
heating system will shut off. The cylinder and fan
will continue to operate even though the airflow
switch is indicating insufficient airflow.
NOTE: To properly mount the airflow switch
bracket, or in case of a load not drying, the airflow
switch bracket may need to be checked for proper
alignment. Be sure the locator pins are securely in
their respective holes before tightening the bracket
mounting screws. This will assure proper
alignment of the airflow switch arm in the channel
of the airflow switch bracket and prevent binding
of the arm.
1
TMB2077N
1
Airflow Switch Actuating Bracket
Figure 15
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
49
Adjustments
Door Strike
The door strike must be adjusted to have sufficient
tension to hold loading door closed against force of the
load tumbling against it. There is proper adjustment of
pull force when 8 to 15 pounds (35.6 N – 66.7 N) is
required to open door.
proceed as follows:
To adjust, open door, loosen acorn nut, and turn door
strike screw in or out as required. Retighten acorn nut.
1
2
9
TMB1990N
1
2
Door Strike Screw
Acorn Nut
Figure 16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
50
Removing Tumbler from Service
If the tumbler is to be removed from service, perform
the following steps where applicable:
• Turn off electrical supply external to machine.
• Turn off electrical disconnect on machine.
• Turn off gas supply external to machine.
• Turn off manual gas shut-off valve on machine.
• Turn off steam supply external to machine.
• Remove all electric, gas and steam connections
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70304601
51
|