AllTrade Air Compressor 835533 User Manual

Model #835533  
AIR COMPRESSOR  
11 Gallon / 3 Peak HP  
0000000  
If you encounter any problems or difficulties, Do not return your compressor to the store!  
Please contact our toll-free customer service department at:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Two Pole Induction Motor  
3450 RPM  
Power  
115V, 60 Hz, 15 Amps  
4.9 SCFM output @ 40 PSI  
3.8 SCFM output @ 90 PSI  
Air Delivery  
Maximum Pressure  
125 PSI  
75%  
Duty Cycle  
3.0 Peak HP / 2.0 Running HP  
11 Gallon Tank  
Oil Lubricated Direct Drive Pump  
Cast Iron Cylinder  
Thermal Overload Protection for Safety  
High Flow Regulator for Precision Air Flow Control  
Tank and Outlet Pressure Gauges  
Duty Cycle:  
This air compressor pump is capable of running continuously. However, in order to prolong the life of your air compressor, it is recommended  
that a 50% to 75% average duty cycle be maintained. Duty cycle refers to the percentage of time a compressor can safely run within a given  
amount of time expressed as a ratio. Example: Oil lubricated compressors are typically rated at a 50% duty cycle, meaning that the compressor  
motor can run about 50% of the total time it is being used to supply air to a tool. During the ON time, the motor is running to pressurize the  
tank. During the OFF time, the motor is stopped and the tools are running off on the pressurized air stored in the tank. If your air tools are  
draining pressure off of the tank too quickly, the compressor motor must run more than 50% of the time the compressor is in use. This can  
lead to overheating and will significantly shorten the life of the compressor.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
This oil lubricated air compressor is designed for Household Use Only and is not intended for commercial applications. It is well suited for do-it-  
yourselfers with a variety of automotive and home uses.  
This instruction manual is intended for your benefit. Please read and follow the safety, installation, maintenance and troubleshooting steps  
described within to ensure your safety and satisfaction. The contents of this instruction manual are based upon the latest product information  
available at the time of publication. The manufacturer reserves the right to make product changes at any time without notice.  
SAFETY ALERT  
READ AND UNDERSTAND THIS ENTIRE INSTRUCTION MANUAL BEFORE ATTEMPTING  
TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THIS AIR COMPRESSOR. FAILURE TO COMPLY  
WITH THE INSTRUCTIONS MAY RESULT IN SERIOUS PERSONAL INJURY AND/OR PROPERTY DAMAGE!  
The following signal words are used to emphasize safety warnings that must be followed when using this air compressor:  
DANGER  
Indicates an imminently hazardous situation that, if not avoided, WILL result in death or serious injury.  
Indicates a potentially hazardous situation that, if not avoided, COULD result in death or serious injury.  
Indicates a potentially hazardous situation that, if not avoided, MAY result in minor or moderate injury.  
Indicates important information which if not followed, MAY cause damage to equipment.  
UNPACKING & INSPECTION  
After opening the carton, unpack your new air compressor and related parts & accessories. Please inspect it carefully for any damage that  
may have occurred during transit. Please check it against the photograph on carton. If any parts are missing, please contact our Consumer  
Helpline:  
Phone: 1-800-423-3598  
DO NOT OPERATE THIS AIR COMPRESSOR IF DAMAGED DURING SHIPMENT, HANDLING OR MISUSE.  
DAMAGE MAY RESULT IN BURSTING, WHICH CAN CAUSE SERIOUS INJURY OR PROPERTY DAMAGE.  
ALL DAMAGED PARTS MUST BE REPAIRED OR REPLACED AS NEEDED PRIOR TO OPERATING THIS AIR COMPRESSOR.  
Check to see that all nuts, bolts and fittings are secure before putting this air compressor into service. If you have any questions, or require  
assistance with damaged or missing parts, please contact our Consumer Helpline:  
Phone: 1-800-423-3598  
Please have the serial number, model number, date of purchase, and parts list (with missing parts identified) available for reference when  
calling.  
MODEL NUMBER: _______________________________________  
SERIAL NUMBER: _______________________________________  
DATE of PURCHASE: ____________________________________  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY WARNINGS  
READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR.  
GENERAL SAFETY WARNINGS:  
• Keep work area clean. Messy areas and cluttered workbenches invite personal injury and/or property damage.  
• Keep children and visitors away. All children should be kept away from the work area. DO NOT let children handle the compressor or  
extension cord. Maintain a safe distance for any person near the work area.  
• Operating any tools or equipment under the influence of drugs, alcohol, or medication can cause personal injury to yourself and others.  
• Wear proper apparel. Remove your jewelry before using air compressor. Do not wear loose clothing, necklaces, rings, bracelets, or other  
jewelry, which may get caught in moving parts. Nonskid footwear and electrically non-conductive gloves are highly suggested while working.  
Wear protective hair covering to contain long hair.  
• Protect your eyes. The operation of any air compressor can result in foreign objects being thrown into the eyes, which can result in severe  
eye damage. Always wear eye protection that meets ANSI Z28.1 specifications during air compressor operation. Eyeglasses are not always  
safety glasses.  
• Be responsible for your hearing. Wear hearing protection during extended periods of operation.  
• Use the right tool. Use tools properly and for their intended task. Do not force a small tool to do the job of a heavy-duty tool. Using the  
right tool to do the right job will make doing the job safer.  
• Check damaged parts before use of any air tools or attachments. A guard or other part that is damaged should be carefully checked to  
ensure that it will operate properly and perform its intended function. Check for misalignment or binding of moving parts, breakage of  
parts, mounting, or any other conditions that may affect tool operation. A guard or other part that is damaged should be properly replaced.  
See replacement parts list for additional details.  
• Avoid unintentional starting. Be sure that your air compressor is in the OFF position before plugging it into a power cord or electrical  
receptacle.  
• Store all maintenance tools away from the immediate area before turning ON your air compressor.  
• Do not overreach. Proper footing and balance is a must at all times while using tools. Unstable support may lead to personal injury. Do not  
stand on the tool. Serious injury could result if the tool tips over or you accidentally contact tool.  
• Never leave the air compressor running unattended. Always turn the power to the OFF position and do not leave the air compressor until  
it comes to a complete stop.  
• When using air accessories, consult the owners manual provided by the manufacturer. The use of improper accessories may cause risk of  
injury to yourself and others.  
• Always make sure the tool is in the OFF position and unplugged from the electrical receptacle when making adjustments, changing parts, or  
performing any maintenance.  
• Secure work. When possible, the use of clamps or a holding device is much safer than holding the work piece with your hands.  
• Keep protective guards in place and in proper working condition.  
• Maintain tools and equipment with care. They will function better and more safely when kept clean and in good working condition. Keeping  
the air compressor clean, dry, and free of grime will add to its life and performance.  
• Childproof the workshop. The use of master switches and padlocks is highly recommended. Remove starter keys where applicable.  
• SOME DUST CREATED BY SPRAYING, BLOWING, POWER SANDING, SAWING, GRINDING, DRILLING AND OTHER CONSTRUCTION  
ACTIVITIES CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER  
REPRODUCTIVE HARM. REDUCE YOUR EXPOSURE TO THESE CHEMICALS BY WEARING APPROVED SAFETY EQUIPMENT SUCH AS DUST  
MASKS THAT ARE DESIGNED TO FILTER OUT MICROSCOPIC PARTICLES.  
• USE OF THIS PRODUCT WILL EXPOSE YOU TO CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS,  
AND REPRODUCTIVE HARM. AVOID INHALING VAPORS AND DUST. WASH HANDS AFTER USING.  
• THIS PRODUCT CONTAINS CHEMICALS, INCLUDING LEAD, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS,  
AND REPRODUCTIVE HARM. WASH HANDS AFTER HANDLING.  
• HANDLING THE POWER CORD ON THIS PRODUCT MAY EXPOSE YOU TO LEAD, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO  
CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER HANDLING.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAIN LIQUID FROM AIR TANK DAILY  
• Use the drain valve located on the bottom of the lower air tank to drain. Failure to properly drain liquid from the tank will cause rust from  
moisture buildup, which weakens the tank and could lead to a violent tank explosion. Periodically inspect the tanks for unsafe conditions  
such as corrosion, cracked welds, and leaks.  
• Release air slowly when draining moisture or depressurizing the air compressor. Fast moving air will stir up dust, dirt and debris that may  
be harmful.  
RISK OF FIRE OR EXPLOSION  
Avoid dangerous environments. Do not spray combustible/flammable liquid in a confined area. Spray area must be well ventilated. Do not  
smoke while spraying or spray where spark or flame is present. Arcing parts — keep compressor at least 20’ away from spraying area and all  
explosive vapors. Do not use compressor near gasoline or other flammable materials. Operate the air compressor in a well-ventilated area.  
Do not direct paint or other spray material towards the compressor. Read and follow all safety instructions for the material you are spraying.  
Be sure to use an approved respirator designed for use with your specific application.  
RISK OF INJURY  
Do not direct air stream at body. Use eye protection. Compressor starts automatically. Do not touch MOVING PARTS. Keep guards in place.  
Compressor does not supply breathable air.  
DANGER  
RISK OF BURSTING  
• Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment. If a regulator has not been  
installed, use only attachment rated at 200 PSI or higher. Do not weld on or repair tank — A DAMAGED TANK MUST BE REPLACED  
IMMEDIATELY. Do not operate without proper safety valve in place.  
• Never attempt to repair or make modifications to the tank or its attachments. Welding, drilling, or any other modifications may weaken  
the tank, which may result in damage from rupture or explosion. Never remove or attempt to adjust the pressure switch, safety valve, or  
other components that control tank pressure. Never substitute parts or attempt to alter the factory set operating pressures.  
RISK OF ELECTRICAL SHOCK  
Disconnect air compressor from power source before servicing. USE PROPERLY grounded ELECTRICAL CONNECTIONS — DO NOT use  
grounding adaptors. Do not use in wet or damp locations or expose to rain. Keep all connections dry and off the ground. Do not allow  
power cords to come into contact with water. Do not touch the plug with wet hands. Do not pull on the electrical cord to disconnect from  
the power outlet. Store air compressor indoors when not in use. Any electrical wiring or repairs performed on this air compressor should be  
done by authorized service personnel in accordance with federal and local electrical codes.  
RISK TO BREATHING  
• This air compressor is not designed, nor intended for the supply of breathable quality air. Air produced by this unit may contain carbon  
monoxide or other toxic vapors. Do not inhale air from the compressor or from a breathing device connected to it.  
• Operate the air compressor in a well-ventilated area. Read and follow all safety instructions for the material you are spraying. Be sure to  
use an approved respirator designed for use with your specific application.  
RISK OF BURNS  
Touching exposed metal such as the compressor head or exhaust tube can result in serious burns. Keep hands and fingers away from  
exposed metal parts on air compressor during or immediately after operation. Air compressors generate significant heat during normal  
operation and will remain hot for some time after use. Do not reach around protective shrouds or attempt any maintenance until compressor  
has been allowed to cool.  
RISK OF FLYING OBJECTS  
Do not direct compressed air stream at people or pets. The powerful compressed air stream can damage exposed skin and easily propel loose  
dirt and other small objects at high-speed, resulting in serious injury. Always wear eye protection that meets ANSI Z28.1 specifications. Use  
only OSHA approved air blowguns. Never leave a pressurized air compressor unattended. Shut OFF air compressor and relieve pressure  
before performing maintenance or repairs. Do not move the air compressor while the air tank is pressurized. Never attempt to move the air  
compressor by pulling on the air hose.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
RISK OF FALLING  
Portable air compressors can fall from a table, workbench, or roof causing damage to the compressor and could result in serious injury or  
death to the operator. Always operate air compressor in a stable and secure position to prevent accidental movement of the unit. Never  
operate air compressor on a roof or other elevated position. Use additional air hose to reach high locations.  
RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR  
Oil can leak or spill and could result in fire or breathing hazard, serious injury or death. Oil leaks will damage carpet, paint, or other surfaces  
in vehicles or trailers.  
AIR TOOLS AND ACCESSORIES  
Do not exceed the pressure rating of any air tools, spray guns, air accessories, or inflatables. Excess pressure can cause them to explode,  
resulting in serious injury. Follow the manufacturers recommended pressure settings for all air tools and air accessories.  
INSTALLATION AND LOCATION  
In order to avoid damaging the air compressor, do not allow the unit to be tilted more than 10º from the normal horizontal position when  
operating.  
The compressor must be run with the rubber feet resting on a flat and stable horizontal surface.  
The air compressor must be used in a clean and well-ventilated area. The compressor requires an unobstructed airflow and must be located a  
minimum of 20 inches from any walls or other obstructions that may prevent proper ventilation. DO NOT place air compressor in an area:  
• Where there is evidence of oil or gas leaks.  
• Where flammable gas vapors or materials may be present.  
• Where air temperatures fall below 32ºF or exceed 104ºF.  
• Where extremely dirty air or water could be drawn into the air compressor.  
SERIOUS INJURY OR DEATH MAY OCCUR IF ELECTRICAL SPARKS FROM MOTOR AND PRESSURE SWITCH COME IN CONTACT  
WITH FLAMMABLE VAPORS, COMBUSTIBLE DUST, GASES OR OTHER COMBUSTIBLE MATERIALS. WHEN USING THE  
AIR COMPRESSOR FOR SPRAYING PAINT, PLACE THE AIR COMPRESSOR AS FAR AWAY FROM THE WORK AREA AS POSSIBLE,  
USING EXTRA LENGTHS OF AIR HOSE TO EXTEND THE WORKING REACH INSTEAD OF EXTENSION CORDS.  
GROUNDING INSTRUCTIONS  
This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape  
wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must  
be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.  
Grounded  
Outlet  
ADAPTER  
Metal Screw  
C
Cover of  
Grounded Outlet Box  
Tab for Grounding  
Screw  
Grounding Pin  
A
B
Figure 1 Grounding Method  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF ELECTRIC SHOCK. IF REPAIR OR REPLACEMENT OF THE  
CORD IS NECESSARY, DO NOT CONNECT THE GROUNDING WIRE TO EITHER FLAT BLADE TERMINAL. THE WIRE WITH GREEN INSULATION  
WITH OR WITHOUT YELLOW STRIPES IS THE GROUNDING WIRE.  
THIS PRODUCT IS FOR USE ON A NOMINAL 120-VOLT CIRCUIT AND HAS A THREE-PRONG GROUNDING PLUG THAT LOOKS LIKE THE PLUG  
ILLUSTRATED IN FIGURE 1. A TEMPORARY ADAPTER SIMILAR TO THE ADAPTER ILLUSTRATED IN SKETCH B AND C (SEE PAGE 5) MAY BE  
USED TO CONNECT THIS PLUG TO A 2-POLE RECEPTACLE AS SHOWN IN ILLUSTRATION B WHEN A PROPERLY GROUNDED OUTLET IS NOT  
AVAILABLE. THE TEMPORARY ADAPTER SHALL BE USED ONLY UNTIL A PROPERLY GROUNDED OUTLET (ILLUSTRATION A) IS INSTALLED BY A  
QUALIFIED ELECTRICIAN. TAB FOR GROUNDING SCREW, LUG, OR SIMILAR PART EXTENDING FROM THE ADAPTER MUST BE CONNECTED  
TO A PERMANENT GROUND SUCH AS A PROPERLY GROUNDED OUTLET BOX COVER. WHENEVER THE ADAPTER IS USED, IT MUST BE HELD  
IN PLACE BY A METAL SCREW.  
THE USE OF A GFCI OUTLET IS STRONGLY RECOMMENDED. THE THIRD PRONG IS TO BE USED TO GROUND THE TOOL AND PROVIDE  
PROTECTION AGAINST ELECTRICAL SHOCK. NEVER REMOVE THE THIRD PRONG.  
CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICEMAN IF THE GROUNDING INSTRUCTIONS ARE NOT COMPLETELY UNDERSTOOD, OR IF  
IN DOUBT AS TO WHETHER THE PRODUCT IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED. IF IT WILL NOT FIT THE  
OUTLET, HAVE THE PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.  
Extension Cords  
THE USE OF AN EXTENSION CORD WITH THIS PRODUCT IS NOT RECOMMENDED as this can result in the loss of power to your air  
compressor which can prevent the motor from starting or running properly. This can also cause your fuse to blow or circuit breaker to trip.  
Running your air compressor on an undersized extension cord will cause permanent damage to internal switches and overheating of the  
electric motor. Use an additional length of air hose rather than an extension cord.  
If you must use an extension cord, it should be plugged into a GFCI found in circuit boxes or protected receptacles. Use only UL listed 3-wire  
extension cords that have a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the product. Make sure your extension  
cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. Refer to  
the guide below for minimum gauge required for extension cords.  
EXTENSION CORD LENGTH  
Up to 25 Feet  
WIRE SIZE (AWG)  
14  
12  
10  
26 to 50 Feet  
51 to 100 Feet  
Use only extension cords that are intended for outdoor use. These cords are identified by a marking “ACCEPTABLE FOR USE WITH OUTDOOR  
APPLIANCES, STORE INDOORS WHEN NOT IN USE.” Examine extension cord before use. DO NOT USE DAMAGED EXTENSION CORDS. Do not  
pull on cord to disconnect from receptacle; always disconnect by pulling on plug. Keep cord away from heat and sharp edges. Always shut OFF  
the air compressor AUTO/ON pressure switch before unplugging the compressor. Always disconnect the extension cord from the receptacle  
before disconnecting the product from the extension cord.  
AVOID ELECTRICAL SHOCK HAZARD. NEVER USE THIS COMPRESSOR WITH A DAMAGED OR FRAYED  
ELECTRICAL CORD OR EXTENSION CORD. INSPECT ALL ELECTRICAL CORDS REGULARLY.  
NEVER USE IN OR NEAR WATER OR IN ANY ENVIRONMENT WHERE ELECTRIC SHOCK IS POSSIBLE.  
TO REDUCE THE RISK OF ELECTROCUTION, KEEP ALL CONNECTIONS DRY AND OFF THE GROUND.  
DO NOT TOUCH THE PLUG WITH WET HANDS.  
Guard against electrical shock. Avoid body contact with grounded services such as pipes, ovens, stoves, and refrigerator enclosures. If not  
properly grounded, this air compressor can incur the potential hazard of light trickle shock, particularly when used in damp locations. If  
electrical shock occurs, there is the potential of secondary hazard such as your hands contacting an operating air tool.  
COMPRESSOR FEATURES  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPRESSOR FEATURES  
9
11  
10  
4
6
3
5
7
1
2
8
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPRESSOR FEATURES  
OIL LUBRICATION: Oil lubricated direct drive pump with cast-iron cylinder for durability.  
1
2
OIL FILL SIGHT GLASS: Located on the face of the crankcase, the oil fill sight glass provides a convenient way to check the oil fill level  
within the pump. The oil level must be checked prior to each use to ensure proper fill level.  
DO NOT OPERATE THE COMPRESSOR WITHOUT LUBRICANT, OR WITH LOW LUBRICATION LEVEL. THE MANUFACTURER IS NOT  
RESPONSIBLE FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION.  
3
AUTOMATIC ON/OFF PRESSURE SWITCH: This compressor is equipped with an automatic ON/OFF pressure switch. The compressor will  
only run when the switch is in the ON/AUTO position. Once the tank has reached the desired preset pressure (“cut-out” pressure), the  
pump motor will automatically shut off. While the switch is in the ON/AUTO position, the pump motor will automatically turn back on  
once the pressure in the tank drops below the minimum preset pressure (“cut-in” pressure).  
DO NOT LEAVE THE COMPRESSOR UNATTENDED WHILE THE POWER SWITCH IS IN THE ON/AUTO POSITION.  
4
5
AIR TANK PRESSURE GAUGE: The tank pressure gauge provides a reading of the air pressure inside of the compressor tank.  
PRESSURE REGULATOR: The regulator allows you to select the amount of air pressure that is output through the air hose into tools and  
accessories. Turn the pressure regulator knob clockwise to increase discharge pressure, and counter clockwise to decrease discharge  
pressure. Please refer to the air delivery requirements of your tools for the proper pressure settings.  
NOTICE: Be careful not to overtighten pressure regulator knob when it “bottoms out” as this may damage pressure regulator.  
OUTLET PRESSURE GAUGE: The outlet pressure gauge provides a reading of the air pressure at the outlet side of the regulator. This  
pressure is controlled by the pressure regulator and is always less than or equal to the air tank pressure.  
6
7
SAFETY RELIEF VALVE: This compressor is equipped with a safety relief valve that is designed to prevent system failures by relieving  
pressure from the system when the air pressure reaches a predetermined level. The safety relief valve is preset by the manufacturer.  
DO NOT attempt to modify or remove the safety relief valve.  
8
9
AIR TANK DRAIN VALVE: Moisture is produced whenever air is compressed. It is critical to drain water from the air tank on this  
compressor frequently. If unit is used only occasionally, tank should be drained after each use and prior to the next use. To drain the tank,  
slowly open the tank drain fitting by turning clockwise. Once all moisture has drained out, close the fitting securely. NOTE: Air tank will  
not pressurize while drain valve is open.  
AIR INTAKE FILTER: This compressor is equipped with an externally accessible air intake filter that is designed to clean air coming into the  
pump. The filter element is easily removed for periodic cleaning. Use compressed air to blow loose dirt and debris from the paper filter  
element and reinstall. Replace paper filter element when necessary.  
A dirty air filter will reduce air compressor performance and can lead to product failure.  
10  
11  
MANUAL THERMAL OVERLOAD SWITCH: The electric motor has a manual thermal overload protector. If the motor overheats for any  
reason, the thermal overload protector will shut off the motor. Turn pressure switch to the “off” position and wait for unit to cool before  
pushing the reset button and restarting the compressor. NOTICE: This air compressor is designed for household use only and is not  
intended to operate heavy-duty air tools. If your applications demands exceed the capacity of this air compressor, a larger air compressor  
that is matched to your application is recommended. If the unit shuts down again, please call the consumer helpline at 1-800-423-3598  
for assistance.  
CARRY HANDLE: Convenient handle for easy transport.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY INSTRUCTIONS  
THE COMPRESSOR IS SHIPPED WITHOUT OIL IN THE CRANKCASE. ADD OIL AS INDICATED BELOW.  
STEP 1 – PUMP LUBRICATION  
This air compressor features an oil lubricated pump that requires the use of SAE 30 weight non-detergent air compressor oil.  
Adding Compressor Oil:  
1. Place air compressor on a flat, level surface.  
2. Remove plastic oil fill  
breather plug (see Fig. 1).  
3. Open supplied oil bottle and pour oil into crankcase until the oil level reaches the center  
of the red circle in the oil level sight glass (see Fig. 2). Be careful not to overfill.  
Fig. 1  
Fig. 2  
4. See diagram for determining proper oil fill level using oil fill sight glass  
(see Fig. 3).  
CAUTION  
5. Install supplied plastic oil fill breather plug securely into oil fill hole.  
CHECK OIL  
LEVEL DAILY!  
OIL LEVEL OK  
REFILL OIL  
IMMEDIATELY  
OIL CAPACITY: 7.7oz (230ml)  
Fig. 3  
DO NOT OPERATE THE COMPRESSOR WITHOUT LUBRICANT, OR WITH LOW LUBRICATION LEVEL. THE MANUFACTURER IS NOT  
RESPONSIBLE FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION.  
STEP 2 – INSPECTION CHECK  
Assembly Check:  
In order to complete the assembly of your new air compressor, a careful inspection should be made to ensure that all of the parts are properly  
aligned and securely fastened.  
1. Inspect air filter to ensure that it is installed and secure.  
2. Check oil fill level in crankcase.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
INITIAL SETUP / BREAK-IN PROCEDURE:  
Do not attach air hose, air tools or other air accessories to the air outlet until break-in procedure has been successfully completed.  
1. Read and understand the entire instruction manual, including all safety warnings before setting up air compressor.  
2. Place air compressor on a flat, level surface.  
3. Check oil fill level in crankcase and add oil as needed.  
4. Turn the pressure regulator knob fully clockwise to open airflow from air outlet port.  
Be careful not to overtighten pressure regulator knob when it “bottoms out” as this may damage pressure regulator.  
5. Turn the power switch to the OFF position.  
6. Plug power cord directly into a properly grounded power source of the correct voltage (see Grounding Instructions on page 5 of this  
instruction manual).  
7. Open the tank drain valve to allow air to escape preventing air pressure buildup in the air tank.  
8. Turn the compressor ON by moving the switch to the AUTO/ON position and run the air compressor for a period of 20 minutes to break-in  
the air pump.  
9. With the compressor still running, at the end of the 20-minute break-in period, close the tank drain valve. The air compressor will build air  
pressure to the maximum preset pressure (“cut-out” pressure) and automatically shut off.  
10. Slowly turn the tank drain valve to open airflow from drain and bleed off air from the air tank. The air compressor will automatically restart  
once the pressure in the air tank drops below the minimum preset pressure (“cut-in” pressure).  
11. Turn the compressor off by moving the switch to the OFF position.  
12. Release pressure from the system. Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise.  
Tilt tank to remove all moisture. Once all the moisture has drained out, close the fitting securely.  
NOTE: Air tank will not pressurize while drain valve is open.  
13. Disconnect the power cord from the power outlet.  
NOTE: Make sure the power switch is in the OFF position when connecting or disconnecting power cord from electrical outlet.  
14. Your new air compressor is now ready to use.  
STARTUP:  
1. Before each startup, make sure the power switch is in the OFF position.  
2. Place air compressor on a flat, level surface.  
3. Check oil fill level in crankcase and add oil as needed.  
4. Release pressure from the system. Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise. Once all  
the moisture has drained out, close the fitting securely. NOTE: Air tank will not pressurize while drain valve is open.  
5. Turn the pressure regulator knob fully counterclockwise to close airflow from air outlet port.  
6. Attach air hose and accessories.  
TOO MUCH AIR PRESSURE CAUSES A HAZARDOUS RISK OF BURSTING. CHECK THE MANUFACTURER’S MAXIMUM PRESSURE RATING FOR  
AIR TOOLS AND ACCESSORIES. THE REGULATOR OUTLET PRESSURE MUST NEVER EXCEED THE MAXIMUM PRESSURE RATING.  
7. Before connecting the compressor to the grounded outlet, check oil level, check for broken components and accessories, and check for  
damage to the hose.  
8. Plug power cord directly into a properly grounded power source of the correct voltage (see Grounding Instructions on page 5 of this  
instruction manual).  
9. Turn the compressor ON by moving the switch to the AUTO/ON position and allow the tank pressure to build. Once the air pressure reaches  
the maximum preset pressure (“cut-out” pressure) it will automatically shut off.  
10.Slowly turn the pressure regulator knob clockwise to open airflow from air outlet port until desired output pressure is reached. NOTE: The  
air compressor will automatically restart once the pressure in the air tank drops below the minimum preset pressure (“cut-in” pressure).  
MAINTENANCE  
DISCONNECT AIR COMPRESSOR FROM POWER SOURCE AND BLEED OFF ALL AIR PRESSURE  
BEFORE ATTEMPTING ANY MAINTENANCE OR REPAIR.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHUTDOWN AND STORAGE:  
NOTE: NEVER stop the air compressor by unplugging it from the power outlet as this may result in damage to the compressor.  
1. Turn the switch to the OFF position  
2. Disconnect the power cord from the power outlet by grabbing the plug (not the cord). Loop around handle for storage.  
3. Turn the pressure regulator knob fully counterclockwise to close airflow from air outlet port. Check the outlet pressure gauge to ensure that  
it reads 0 PSI.  
4. Remove the air hose and any air accessories.  
5. Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise. Tilt tank to remove all moisture. Once all  
the moisture has drained out, close the fitting securely.  
6. Allow the compressor to cool down.  
7. Wipe the air compressor clean and store it in a clean, dry, and non-freezing location.  
WHEN PERFORMING ANY MAINTENANCE OR SERVICE:  
1. The air compressor must be turned off.  
2. Disconnect compressor from the power source.  
3. Open tank drain to bleed off all air pressure before attempting any maintenance or repair.  
4. Allow compressor to fully cool before attempting any maintenance or repair.  
Check the air compressor frequently for any visible problems and follow maintenance procedures each time the compressor is used.  
All air compressors contain maintenance parts that require periodic replacement. These used parts, including air filters and used lubricating oil,  
may contain regulated substances that must be disposed of in accordance with local, state, and federal laws and regulations.  
1. Turn compressor off and release pressure from the system. Drain moisture from the air tank by slowly opening the air tank drain valve by  
turning clockwise. Tilt tank to remove all moisture. Once all the moisture has drained out, close the fitting securely.  
2. Wipe the compressor clean.  
MAINTENANCE CHECKLIST:  
Daily:  
• Check oil level.  
Weekly:  
Six months or 200 operating hours:*  
• Change compressor oil. Use only SAE  
30 weight non-detergent air  
compressor oil.  
• Replace oil more frequently when  
used in dusty operating environments.  
• Inspect and clean air filter.  
• Clean breather holes on oil fill plug.  
• Drain accumulated liquid from tank.  
• Check for oil leaks.  
• Check for unusual noise and/or vibrations.  
• Check that all fasteners are secure.  
• Wipe compressor clean.  
Monthly:  
• Check for air leaks.  
• Check safety relief valve.  
+
+
Apply a solution of soapy water around joints. Look for air bubbles around joints when compressor reaches the pressure cut-out limit and the  
pump turns off.  
* The pump oil must be changed after the first 20 hours of operation. Thereafter, change oil every 200 hours of operation or every six months,  
whichever comes first. In harsh operating conditions, maintenance must be performed more frequently.  
OIL CHANGE:  
Used lubricating oil may contain regulated substances that must be disposed of in accordance with local, state, and federal laws and regulations.  
1. The air compressor must be turned OFF.  
2. Allow compressor to fully cool before attempting any maintenance or repair.  
3. Place a suitable oil drain pan below oil drain plug (see Fig. 4).  
4. Remove oil fill breather plug to allow air to enter crankcase.  
5. Remove oil drain plug.  
6. Allow oil to drain completely. Tilt air compressor towards the oil drain to assist draining.  
7. Clean and replace oil drain plug.  
8. Refill crankcase with SAE 30 weight non-detergent air compressor oil until the oil level  
reaches the center of the red circle in the oil level sight glass. Be careful not to overfill.  
9. Reinstall the oil fill breather plug.  
Fig. 4  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHECKING SAFETY RELIEF VALVE:  
SAFETY RELIEF VALVE MUST BE REPLACED IF IT CANNOT BE ACTUATED OR IT LEAKS AIR AFTER THE RING IS RELEASED.  
1. The air compressor must be turned OFF.  
2. Disconnect compressor from the power source.  
3. Open tank drain to bleed off all air pressure before attempting any maintenance or repair.  
4. Allow compressor to fully cool before attempting any maintenance or repair.  
5. Grasp the wire ring on the safety relief valve.  
6. Pull and release the ring a few times to ensure that the plunger moves in and out. Replace the safety relief valve if plunger does not move or  
is difficult to move.  
CHECKING AIR FILTER ELEMENT:  
1. The air compressor must be turned OFF.  
2. Disconnect compressor from the power source.  
3. Open tank drain to bleed off all air pressure before attempting any maintenance or repair.  
4. Allow compressor to fully cool before attempting any maintenance or repair.  
5. Remove the face of the filter body to access the filter element by pushing and rotating the front portion of the filter body in a counter  
clockwise direction to release the locking tabs.  
6. Use compressed air to blow loose dirt and debris from the paper filter element. Replace filter element if it cannot be cleaned sufficiently.  
7. Reinsert filter element into filter body and reinstall filter faceplate.  
MOISTURE IN COMPRESSED AIR  
Moisture is a normal by-product of compressing air. As the moisture builds during compressor use, it can be carried though the air hose. When  
using paint spray gun or sandblasting gun, the use of a special filter to remove moisture from the air line is highly recommended. Moisture in  
the compressed air will cause water spots in paint jobs and cause blasting media to clog the sandblasting gun.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
Problem Encountered  
Possible Cause  
Possible Solution  
The compressor does not  
start or restart:  
Power cord not plugged in.  
Plug cord into grounded outlet.  
Move switch to AUTO position.  
Motor/Pressure switch in  
OFF position  
Motor thermal overload switch has  
tripped.  
Turn air compressor off, wait until the motor is cool, then  
press motor thermal overload (red) button firmly until click  
is heard.  
Fuse blown or circuit breaker has  
tripped.  
Replace fuse or reset circuit breaker.  
Check for proper fuse amperage.  
Check for low voltage conditions.  
Disconnect any other electrical appliances from circuit or  
operate air compressor on its own branch circuit.  
Wrong gauge wire or length of  
extension cord.  
Check chart in instruction manual for proper gauge wire  
and cord length.  
Air tank pressure exceeds motor/pressure  
switch "cut-in" pressure.  
Motor will start automatically when air tank pressure drops  
below "cut-in" pressure of motor/pressure switch.  
Pressure release valve on  
Bleed the line by moving the switch to the OFF position.  
motor/pressure switch has not  
unloaded pump head pressure.  
Defective motor, motor capacitor,  
motor/pressure switch.  
Contact Consumer Helpline at 1-800-423-3598.  
The compressor motor stalls:  
Excessively noisy operation:  
Overloaded motor.  
Have a certified electrician check the motor and wiring.  
Proceed with his or her recommendations.  
Improper lubrication.  
See LUBRICATION section in instruction manual.  
Check oil level and fill if necessary.  
Low oil level.  
Defective check valve.  
Replace check valve.  
Loose motor pulley or pump flywheel.  
Lack of oil in the pump crankcase.  
Tighten pulley and/or flywheel (where applicable).  
Check oil level. If low, check for possible bearing damage.  
Add correct amount of oil.  
Carbon deposits on pistons or valves.  
Remove cylinder head and inspect. Clean or replace parts  
as needed.  
Bearing, piston or connecting rod  
failure.  
STOP THE COMPRESSOR! Contact Consumer Helpline at  
1-800-423-3598.  
Worn connecting rod.  
Replace with new connecting rod.  
Worn piston wrist pin bushing.  
Remove piston/connecting rod assembly from the compressor  
and inspect for excess wear. Replace worn parts as needed.  
Worn bearings.  
Replace worn bearings as needed.  
NOTE: Dirty oil can cause accelerated wear.  
Change oil frequently using recommended oil.  
Noisy check valve.  
Replace check valve.  
When in the Start/Stop  
option, motor runs  
continuously:  
Motor/Pressure switch does not shut  
off motor when air compressor  
reaches "cut-out" pressure and safety  
relief valve activates.  
Move the motor/pressure switch to the OFF position. If the  
motor does not shut off, unplug the air compressor. If the  
electrical contacts are welded together, replace the pressure  
switch.  
Air compressor is incorrectly sized.  
Limit the air pressure to the capacity of the air compressor.  
Either use a smaller tool or a larger air compressor.  
Overheating:  
Poor ventilation  
Relocate the air compressor to an area with an ample supply  
of cool, dry, and well-circulated air is available.  
Dirty cooling fins.  
Clean the outer surfaces of the cooling fins on the pump and  
motor assembly.  
Air continues to leak at  
motor/pressure switch release  
valve after motor stops:  
Defective pilot valve, the check valve is Remove, clean or replace.  
stuck open.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
Possible Solution  
Problem Encountered  
Possible Cause  
Air continues to leak at  
motor/pressure switch release  
valve while motor is running:  
Defective motor/pressure switch.  
Check valve stuck in open position.  
Replace.  
Replace check valve. DANGERDo not disassemble the  
check valve with tank pressurized. Open tank petcock valve  
to allow air to escape from tank prior to servicing.  
Air leaks from safety relief  
valve:  
Possible defective safety relief valve.  
Operate safety relief valve manually by pulling on ring. If it  
still leaks, it should be replaced.  
Excessive tank pressure.  
Blown gaskets.  
Defective motor/pressure switch. Replace.  
Air leaks at pump:  
Replace blown gaskets and torque head bolts to 20 ft./lbs.  
CAUTIONReplace head gasket with a new one each time  
the head is removed to ensure proper sealing.  
Air leaks at fittings:  
Fittings are not tight enough.  
Defective or rusted air tank.  
Damaged inlet (reed) valve.  
Tighten fittings where air can be heard escaping. Check  
fittings with soapy water solution. DO NOT OVERTIGHTEN.  
Air leaks in air tank:  
Air tank must be replaced. DO NOT ATTEMPT TO REPAIR  
AIR TANK!  
Air blowing from inlet filter:  
Contact Consumer Helpline at 1-800-423-3598.  
Adjust pressure regulator knob to proper setting.  
Insufficient pressure at air tool Pressure regulator knob is not turned  
or air accessory:  
to high enough pressure.  
Defective motor/pressure regulator  
switch.  
Replace.  
Restricted air intake filter.  
Air leaks.  
Clean or replace the filter element.  
Check for leaks by applying soap solution to all fittings and  
connections. Bubbles will appear at leakage points. Tighen or  
replace leaking fittings or connections as needed.  
Hose or hose connections are too  
small or long.  
Replace with larger hose or connectors.  
Air compressor is not large enough for Check the accessory air requirement. If it is higher than the  
air requirement.  
CFM or pressure supply of the air compressor, you need a  
larger air compressor.  
Air compressor not making  
enough air:  
Restricted air intake filter.  
Leaking (reed) valve.  
Clean or replace the filter element.  
Drain air tank and measure pump up time. Compare to  
specifications. If lower, remove pump head and inspect valve  
plate, valve seats, and valve reeds. Clean or replace as needed.  
Restricted pilot valve.  
Low compression.  
Clean or replace.  
Low pressure may be due to worn piston rings and cylinder  
walls. Inspect for excessive wear and replace worn parts as  
needed.  
Excessive oil consumption:  
Restricted air intake filter.  
Clean or replace air filter element.  
Air compressor on unlevel surface.  
Do not incline the air compressor more than 10 degrees in  
any direction while running.  
Crankcase overfilled with oil.  
Drain oil. Refill to proper level with 30 weight non-detergent  
air compressor oil  
Plugged oil dipstick vent.  
Oil leaks.  
Clean and check breather for proper ventilation.  
Repair.  
Worn piston rings or scored cylinder.  
Improper oil viscosity.  
Replace worn or damaged parts as needed.  
Drain oil. Refill to proper level with 30 weight non-detergent  
air compressor oil.  
Oil has milky appearance:  
Moisture in discharge air:  
Water in oil due to condensation.  
Change oil and move air compressor to a less humid  
environment.  
Condensation in air tank caused by  
high level of atmospheric humidity or  
air compressor is not running long  
enough.  
Drain tank after every use. Drain air tank more often in  
humid weather and use an air line filter.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
NO. PART NO.  
DESCRIPTION  
QTY  
NO. PART NO.  
DESCRIPTION  
QTY  
1
835533-1  
Bolt M6x40  
Cylinder Head  
Air Filter  
4
1
1
1
1
1
1
2
1
2
1
3
1
1
2
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
4
1
1
6
1
1
1
1
2
2
2
2
2
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
835533-55  
835533-56  
835533-57  
835533-58  
835533-59  
835533-60  
835533-61  
835533-62  
835533-63  
835533-64  
835533-65  
Bolt M10  
2
1
1
1
1
1
2
1
1
1
1
2
835533-2  
Foot  
3
835533-3  
Nut  
4
835533-4  
Cylinder Head Gasket  
Valve Plate  
Valve Plate Gasket  
Valve Clack  
Valve Clack Pin  
Cylinder  
Power Cord  
Internal Wire  
Pressure Switch  
Pressure Gauge  
Quick Coupler  
Regulator Valve  
Safety Valve  
Circuit Breaker  
5
835533-5  
6
835533-6  
7
835533-7  
8
835533-8  
9
835533-9  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
835533-10  
835533-11  
835533-12  
835533-13  
835533-14  
835533-15  
835533-16  
835533-17  
835533-18  
835533-19  
835533-20  
835533-21  
835533-22  
835533-23  
835533-24  
835533-25  
835533-26  
835533-27  
835533-28  
835533-29  
835533-30  
835533-31  
835533-32  
835533-33  
835533-34  
835533-35  
835533-36  
835533-37  
835533-38  
835533-39  
835533-40  
835533-41  
835533-42  
835533-43  
835533-44  
835533-45  
835533-46  
835533-47  
835533-48  
835533-49  
835533-50  
835533-51  
835533-52  
835533-53  
835533-54  
Hex Bolt M8x25  
Cylinder Gasket  
Piston Ring  
Piston  
Piston Pin  
Circlip  
Bolt M6x10  
Crank Case Cover  
Oil Leveler Gasket  
Oil Leveler  
Bolt M6x10  
Circlip  
Rubber Gasket  
Connecting Rod  
Hex Bolt M8x22 (Left)  
Crank  
Crank Case  
Sealing Ring  
Bearing 6204  
Stator  
Rotor  
Bearing 6204  
Wave Washer D35  
Motor Cover  
Bolt M5x105  
Fan  
Circlip  
Connector  
Fan Cover  
Nut M8  
Dentation Washer  
Capacitor  
Nut M8  
Check Valve  
Tubing  
Bolt M8x25  
Tubing  
Handle  
Air Tank  
Drain Valve  
Nut M10  
Spring  
Washer  
Bushing  
Wheel  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS DIAGRAM  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ONE YEAR LIMITED WARRANTY  
ALLTRADE TOOLS LLC AIR COMPRESSORS  
Express and Exclusive Limited Warranty to Original Retail Buyer  
Alltrade Tools LLC (hereinafter “Alltrade”) expressly warrants to the original retail purchaser of the accompanying air compressor and no one  
else all parts of the product (except those parts referred to below which are specifically excluded from such warranty (see Exclusions)) to be free  
from defects in materials and workmanship during the following periods from the original date of purchase:  
For one (1) year from the date of purchase:  
• Compressor Pump  
• Plumbing  
Tank assembly  
For six (6) months from date of original purchase:  
• Pressure Switch  
• Pilot Valve  
• Copper/Stainless Steel Line  
• Regulator  
• Check Valve  
For ninety (90) days from the original date of purchase:  
• Pressure Gauge  
• Drain Valve  
• Safety Release Valves  
• Quick Couplers  
For thirty (30) days from the original date of purchase:  
• Air Accessories  
The date of purchase shall be the date of shipment to the original purchaser, or the date the original purchaser took possession, custody or  
control of the product, whichever occurred first. This warranty shall be null and void if the product or any component thereof is modified or  
altered. This warranty does not apply to any other product and/or component thereof manufactured or distributed by Alltrade, and does not  
apply to products and/or components thereof designed, manufactured and/or assembled by others, for which Alltrade makes no warranties  
whatsoever. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.  
Warranty Performance  
By purchasing the product, purchaser expressly acknowledges and agrees that their sole and exclusive remedy under this warranty shall be  
strictly limited to the repair or replacement of any covered nonconforming items or parts thereof provided that any such nonconforming item  
and/or part is promptly returned to Alltrades facility postage pre-paid and insured (ADDRESS: ALLTRADE Warranty Claims & Repair, 1431 Via  
Plata, Long Beach, CA 90810, Attn: Customer Service (TELEPHONE: (800) 423-3598)) within the applicable warranty period, with a written  
request by purchaser that Alltrade repair and/or replace the nonconforming item and/or part. We recommend that you keep the original  
product packaging in the event you need to ship the unit. We suggest the package be insured against loss or in transit damage. When sending  
your product include your name, address, phone number, dated proof of purchase (or copy), and a statement about the nature of problem.  
Warranty coverage is conditioned upon purchaser furnishing Alltrade with adequate written proof that they are the original purchaser and of  
the original purchase date. Parts returned, freight prepaid and insured, to Alltrades facility (see above address) will be inspected and, at  
Alltrades option, repaired and/or replaced free of charge if found to be defective and subject to warranty. Alltrade retains the sole discretion to  
determine whether any item or part is nonconforming and, if so, whether the item and/or part will be repaired and/or replaced. If Alltrade  
chooses to replace the product, it may replace it with a new or reconditioned one of the same or comparable design. The repaired or replaced  
unit will be warranted under the terms of the remainder of applicable warranty period(s). Typically, covered defective parts not subject to normal  
wear and tear or other exclusions will be repaired or replaced, at Alltrades option, during the above stated warranty periods. Alltrades repair  
and/or replacement of any nonconforming item and/or part thereof shall constitute fulfillment of all obligations to the purchaser. Alltrade shall  
not be responsible or liable for any expense, including freight charges, or repairs made outside Alltrades facility, unless expressly agreed to by  
Alltrade in writing. Under no circumstances shall Alltrade bear any responsibility for loss of the unit, loss of time or rental, inconvenience,  
commercial loss or consequential damages.  
Exclusions  
This warranty does not cover parts damaged due to normal wear, abnormal conditions, misapplication, misuse, abuse, accidents, operation at  
other than recommended pressures or temperatures, improper storage or freight damage. Parts damaged or worn by operation in dusty  
environments are not warranted. Failure to follow recommended operating and maintenance procedures also voids warranty.  
The following additional items are not covered under this warranty: pump or valve failure caused by rain, excessive humidity, corrosive  
environments or other contaminants; cosmetic defects that do not interfere with compressor functionality; and rusted tanks, including but not  
limited to rust due to improper drainage or corrosive environments.  
This warranty shall not apply when: the air compressor has been used for commercial or rental purposes; defects in materials or workmanship  
or damages result from repairs or alterations which have been made or attempted by others or the unauthorized use of nonconforming parts;  
damage is due to abuse (including overloading of the air compressor beyond capacity), improper maintenance, neglect or accident, or the  
damage is due to use of the air compressor after partial failure or use with improper accessories.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alltrade will not be liable for the following: labor charges, loss or damage resulting from improper operation, maintenance or repairs made by  
other persons; pre-delivery services such as assembly, oil or lubricants, and adjustment; maintenance services that are normally required to  
maintain the air compressor.  
The use of other than genuine Alltrade Repair Parts will void warranty.  
Warranty Disclaimers  
EXCLUSION AND DISCLAIMER OF ALL OTHER EXPRESS WARRANTIES, GUARANTIES AND/OR REPRESENTATIONS. EXCEPT FOR THE LIMITED  
WARRANTY PROVIDED ABOVE, ALL OTHER EXPRESS WARRANTIES, GUARANTIES AND/OR REPRESENTATIONS BY ALLTRADE AND/OR ITS  
REPRESENTATIVE(S) REGARDING THE DESIGN, MANUFACTURE, PURCHASE, USE AND/OR OPERATION OF THE AIR COMPRESSOR OR ANY  
COMPONENT THEREOF SOLD HEREUNDER, REGARDLESS OF WHETHER ANY SUCH WARRANTY, GUARANTY AND/OR REPRESENTATION,  
WRITTEN OR ORAL, ARISES BY OPERATION OF LAW AND/OR EQUITY AND/OR BY ANY ACT OR OMISSION OF ALLTRADE AND/OR ITS  
REPRESENTATIVE(S), OR THE BUYER, ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED BY ALLTRADE AND/OR ITS REPRESENTATIVES.  
PURCHASER KNOWINGLY AND WILLINGLY WAIVES ANY AND ALL SUCH WARRANTIES AND RIGHTS, CLAIMS AND/OR CAUSES OF ACTION  
ARISING THEREFROM OR BASED THEREON. PURCHASER’S SOLE AND EXCLUSIVE REMEDY IS AS STATED ABOVE.  
EXCLUSION AND DISCLAIMER OF ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE. NO WARRANTY, ORAL OR WRITTEN, OTHER THAN THE ABOVE WARRANTY IS MADE WITH REGARD TO THIS AIR  
COMPRESSOR. ALL EXPRESS AND/OR IMPLIED WARRANTIES, GUARANTIES AND/OR REPRESENTATIONS BY ALLTRADE AND/OR ITS  
REPRESENTATIVE(S) REGARDING THE DESIGN, MANUFACTURE, PURCHASE, USE AND/OR OPERATION OF THE AIR COMPRESSOR OR ANY  
COMPONENT THEREOF SOLD HEREUNDER, REGARDLESS OF WHETHER ANY SUCH WARRANTY, GUARANTY AND/OR REPRESENTATION,  
WRITTEN OR ORAL, ARISES BY OPERATION OF LAW AND/OR EQUITY AND/OR BY ANY ACT OR OMISSION OF ALLTRADE AND/OR ITS  
REPRESENTATIVE(S), OR THE PURCHASER, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE  
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED BY ALLTRADE AND/OR ITS  
REPRESENTATIVES. PURCHASER KNOWINGLY AND WILLINGLY WAIVES ANY AND ALL SUCH WARRANTIES AND RIGHTS, CLAIMS AND/OR  
CAUSES OF ACTION ARISING THEREFROM OR BASED THEREON.  
PURCHASER’S SOLE AND EXCLUSIVE REMEDY IS AS STATED ABOVE.  
Limitation Of Liability  
IN NO EVENT SHALL ALLTRADE AND/OR ITS REPRESENTATIVE(S) BE LIABLE FOR INDIRECT, INCIDENTAL, SPECIAL AND/OR CONSEQUENTIAL  
DAMAGES OF ANY KIND ARISING OUT OF OR RELATED TO, DIRECTLY OR INDIRECTLY, ANY BREACH OF ANY PROVISION OF ANY AGREEMENT  
BETWEEN ALLTRADE AND/OR ITS REPRESENTATIVE(S) AND PURCHASER, ANY WARRANTY HEREUNDER, AND/OR THE EXISTENCE, DESIGN,  
MANUFACTURE, PURCHASE, USE AND/OR OPERATION OF ANY ITEM(S) SOLD HEREUNDER EVEN IF ALLTRADE AND/OR ITS REPRESENTATIVE(S)  
HAS BEEN ADVISED OF THE POSSIBILITY OF ANY SUCH DAMAGES. IN NO EVENT, WHETHER AS A RESULT OF A BREACH OF CONTRACT,  
WARRANTY, TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL ALLTRADE’S AND/OR ITS REPRESENTATIVE(S)’ LIABILITY EXCEED THE  
PRICE OF THE AIR COMPRESSOR. ANY AND ALL LIABILITY CONNECTED WITH THE USE OF THIS AIR COMPRESSOR SHALL TERMINATE UPON  
THE EXPIRATION OF THE WARRANTY PERIODS SPECIFIED ABOVE.  
Limitations on Warranty Disclaimers  
Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of the  
incidental or consequential damages, so part or all of the above limitations or exclusions may not apply to you. This warranty gives you specific  
legal rights, and you may also have other rights which vary from state to state.  
If your product is not covered by this warranty, please call our Customer Service Department at (800) 423-3598 for general repair information  
and charges.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALLTRADE TOOLS LLC  
1431 VIA PLATA  
LONG BEACH, CA 90810-1462  
©COPYRIGHT 2006, ALLTRADE TOOLS LLC REV.1  
WARNING ¥ ADVERTENCIA  
WEAR SAFETY GLASSES  
USE GAFAS  
DE SEGURIDAD  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch 4007 User Manual
4XEM Security Camera IPCAMWFD User Manual
Aastra Telecom Telephone 9417CW User Manual
Acoustic Research Universal Remote ARRX15G User Manual
ACR Electronics Marine Lighting 1933 User Manual
AEG Washer W 808 User Manual
Aiphone Home Security System JDW C User Manual
Altinex Network Card TNP100UK User Manual
Bakers Pride Oven Convection Oven COB GD User Manual
Balance Model Vehicle 10505 User Manual