0311 A OI
GTW-LC
SERVICE MANUAL
GT System Lift control adaptor
GTW-LC
INSTALLATION & OPERATION MANUAL
Download from Www.Somanuals.com. All Manuals Search And Download.
1-1
SYSTEM CONFIGURATION
1
1-1
System Configuration
a. GT expanded system (For details, see the GT Series Installation & Op-
eration Manual.)
Make sure to use GT-BCX, GT-DA(-L), GT-NS(-V), GT-DM(V).
[1] Expanded Bus control unit GT-BCX
[2] Distribution terminal (junction): Not included
[3] Lift control adaptor GTW-LC
[7]
#16
[6]
Relay contacts: 20
[4] Bus control unit GT-BC
[3] GTW-LC
[5] Power supply PS-2420DIN etc.
[6] Lift controller (made by other manufacturer)
[7] Lift (made by other manufacturer)
[8] Entrance station (digital name scrolling type): Audio only or Audio/
video
Max. 8
Do not use direct selection GT-SW.
Capacity
#9
#8
Lift control adaptor Maximum 16 adaptors (up to 8 adaptors per trunk)
* Capacity of other units conform to the expanded system.
[3] GTW-LC
1-2
Wiring Distance
* DP = Distribution Point
[7]
[6]
0.65 mm
0.8 mm
1.0 mm
(22 AWG)
(20 AWG)
(18 AWG)
Diameter of wires
[3] GTW-LC
300 m
GT-BCX ~ GTW-LC
-
-
-
-
-
-
-
-
-
’
(980 )
300 m
GT-BCX ~ GT-BC
DP ~ GTW-LC
’
(980 )
Max. 8
300 m
’
(980 )
5 m
#1
GT-BC ~ DP
-
’
(16 )
5 m
5 m
GT-BC ~ power supply
’
’
(16 )
(16 )
[3] GTW-LC
Total wiring distance
GT-BCX ~ GTW-LC
2500 m
-
’
(8200 )
[4]
GT-BC
* For other Wiring Distances, see the GT Series Installation & Operation
Manual.
[5]
PS24
[2]
DP
[8]
Sub trunk
Common trunk
Entrance Station (Unit Type)
1
2
B
A
3
E
C
L
D
F
PS24
4
H
G
I
J
5
K
6
N
M
O
P
7
Q
R
S
T
8
U
W
9
V
X
Y
Z
0
[1]
GT-BCX
or
Entrance Station (Integrated Type)
a GT Expanded System
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
NAMES
2
3
[3]
GTW-LC
Contents
Lift control adaptor GTW-LC (mounting bracket is included)
[3]
[1]
[2]
[4]
Names
[1] Bus line terminal
[2] ID setting switch
[3] Relay output terminal
[4] Lock release lever
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
MOUNTING
4
[1]
[1]
GTW-LC
[2]
Mounting
[1] Din rail
[2] Lock release lever
Mount GTW-LC to the Din rail.
* To remove GTW-LC, pull the lock release lever down.
GTW-LC cannot be mounted directly to the wall surface.
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
5
[3]
#8
RY1
1P
NP
GT-BCX
1P
NP
GTW-LC
R1
R2
1P
NP
RY20
to
Max. 8
Lift controller
[3]
#1
RY1
1P
NP
#9 to #16
(max. 8)
GT-BCX
1P
NP
GTW-LC
R1
R2
1P
NP
RY20
GTW-LC
ON
ON
ON
1
#1
#2
#5
#9
#13 ON
1
2
2
3
3
4
1
2
2
2
2
3
4
4
4
4
2
2
3
3
4
4
1
2
2
2
2
3
3
3
3
4
4
4
4
ON
ON
#6
#10 ON
#14 ON
1
4
1
3
3
3
1
1
1P
NP
ON
#11 ON
#7
#15 ON
ON
#3
#4
1
1
#16 ON
1
1
2
2
3
3
4
1
#12 ON
1
2
2
3
3
4
4
ID
ON
ON
#8
1
1
4
1P
NP
[4]
[2]DP
GT-BC
1P
NP
R1
+
–
4
3
2
1
R1
R2
PS24
R2
1P
NP
[5]
PS24
[1]
Sub trunk
R1 R2
GTW-LC
1
2
3
A
B
C
D
E
F
4
H
G
Entrance Station
(Unit Type)
I
J
5
K
L
M
6
N
O
P
7
Q
R
S
T
8
U
W
9
V
X
Y
Z
0
PS-2420, PS-2420S,
PS-2420UL
PS-2420DIN
or
Common trunk
+
–
GT-BCX
PS24
Entrance Station
(Integrated Type)
a GT Expanded System
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring
a. GT expanded system (For details, see the GT Series Installation & Op-
eration Manual.)
[1] Expanded Bus control unit GT-BCX
[2] Distribution terminal (junction): Not included
[3] Lift control adaptor GTW-LC
Maximum 16 adaptors (up to 8 adaptors per trunk)
ID: ID setting switch (factory setting is #1)
•
Make sure to set corresponding ID number.
[4] Bus control unit GT-BC
[5] Power supply PS-2420DIN etc.
NP: Non-polarized
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup tool
SETTING UP
6
6-1
1
* Completing settings with the setup tool is required.
1. Install the setup tool in the PC (Windows 7/VISTA/XP ®) beforehand,
and then enter the resident information.
* For details on the setup tool, refer to the GT Series Installation & Op-
eration Manual.
Save programmed data and resident information data to your PC is rec-
ommended.
2. Connect the PC terminal of GT-BCX to the PC with USB cable (A-B
type) (included with GT-NS(-V), GT-MK, GT-DM(V)).
* PC requires USB output.
3. Start the setup tool (double-click gt_program.exe).
4. Select the system (GT or GH).
2
GT-BCX
5. After inputting resident information and clicking OK, the“Lift Control
1”tab and“Lift Control 2”tab will appear if“Lift Control”is selected
in the“View”menu.
USB Cable (A-B type)
If resident information is not input, the“Lift Control 1”tab and“Lift
Control 2”tab will not appear.
3
4
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
6-2
6-3
[1]
[2]
[1]
[2]
[3]
[4]
Lift Control 2
[5]
[1] The resident information that has been entered will be displayed.
[2] Set which relay will activate in the corresponding GTW-LC for each
residence. The setting range is“1 to 20”.
Lift Control 1
[1] GTW-LC ID
[2] Select“ON”or“OFF”for the GTW-LC connection.
[3] Select“N.O.”or“N.C.”for the Output Type.
[4] Set the Timer. The time setting range is“1 to 600”sec. (one second
increments)
6-4
1
•
Clicking the upper spin button will increase the time setting, and clicking the
lower spin button will decrease the time setting. At this time, a numerical value
exceeding either the upper or lower value limits cannot be set.
The number of seconds can be input directly by clicking inside of the Timer
box.
•
•
Input can be set by pressing the Enter key or by clicking inside of another Timer
box.
[5] After GT system settings are completed, the connected GTW-LC ID
numbers will display in black if the“Check”button is clicked while
connected to GT-BCX.
2
The system will be in use when Connecting status is being checked.
Checking connections is not possible while the system is in use.
Data transfer
1. Select“Export”in the“Connection”menu.
2. If“Yes”is selected, the data will be transferred to GT-BCX.
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONS
6-5
1
7
7-1
1
1
2
C
F
2
B
4
H
3
E
J
5
K
O
P
7
6
N
Q
R
S
S
9
V
8
U
X
Y
Z
W
9
X
Z
Y
0
2
2
Residential Station or Security Guard Station Door Release
1. Press the door release button at the residential station or security guard
station while in communication with the entrance station that made a
call.
2. The door release function will activate on the entrance station that is in
communication, and the lift will begin to move.
3
4
The lift operates according to the lift controller settings.
* In the cases below, the lift will not move.
•
If the talk button is pressed and the residential station goes into talk mode while
the entrance is being monitored.
•
When the entrance station access code is input and the door is released. In this
case, using a proximity card etc. to activate the lift to go to their specific floor.
(This function depends on the lift.)
7-2
1
DOCTOR
Combine Data
2
The data entered in the GT-BCX can be combined with the data entered
in the GT-NS(V), GT-MK or GT-DM(V), and this data can be saved as
master data.
* Import the data entered into the GT-NS(V), GT-MK, GT-DM(V) and
GT-BCX before this process.
1. Select and open the corresponding data with“Open”in the“File”
menu.
2. Selecting“Lift Control”in the“View”menu makes it possible to se-
lect“Combine Data”in the“File”menu.
Automatic Entry (Doctor Call) Option
1. A visitor presses the call button of the entrance station.
2. If the automatic entry is set, the release mechanism is activated and the
lift will begin to move at the same time.
3. Select and open the corresponding data.
4. Click the checkboxes for the items to be combined, and select“Com-
bine”to combine the data. Assign a file name and save.
The lift operates according to the lift controller settings.
For details on the automatic entry (doctor call), refer to the GT Series Installa-
•
tion & Operation Manual.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL PRECAUTIONS
SPECIFICATIONS
Specifications
Power supply: Supplied by GT-BC
Relay contacts: 20
8
9
Technical precautions
°
+
°
+
°
+
°
•
•
Operating temperature: 0 C to 40 C ( 32 F to 104 F)
Repair requests: When units do not operate properly, contact a qualified
technician for service.
•
•
AC/DC 24 V, 500mA, N.O./N.C. dry closure operation time ac-
%
2
curacy
single-pair cable
•
•
Wiring:
Type of cable: Pair cable (solid wire not stranded), polyethylene insulated, di-
ameter 0.65 ~ 1.0 mm
•
•
Dimensions:
210 (W) x 108.5 (H) x 61 (D) mm
(8-1/4 x 4-1/4 x 2-3/8 inch)
Approx. 330 g (0.7 lbs.)
Weight:
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures: • Reorient or relocate the receiving antenna • Connect the equipment into an
outlet on a circuit different from that to which the receiver is connected. Increase the
separation between the equipment and receiver. • Consult the dealer or an experienced
radio/TV technician for help.
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under nor-
mal use and service for a period of two years after delivery to the ultimate user and will repair
free of charge or replace at no charge, should it become defective upon which examination
shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to
make the final decision whether there is a defect in materials and/or workmanship; and whether
or not the product is within the warranty. This warranty shall not apply to any Aiphone prod-
uct which has been subject to misuse, neglect, accident, or to use in violation of instructions
furnished, nor extended to units which have been repaired or altered outside of the factory.
This warranty does not cover batteries or damage caused by batteries used in connection with
the unit. This warranty covers bench repairs only,and any repairs must be made at the shop or
place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred
involving on site service calls. Aiphone will not provide compensation for any loss or damage
incurred by the breakdown or malfunction of its products during use, or for any consequent
inconvenience or losses that may result.
The object area of (WEEE) is EU.
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE S.A.S., LISSES-EVRY, FRANCE
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|