Advantech Switch EKI 2525M User Manual

EKI-2525M  
Industrial 5-port Unmanaged  
Ethernet switch with 1-port 100FX  
EKI-2526M  
Industrial 5-port Unmanaged  
Ethernet switch with 2-port 100FX  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Warranty (2 years)  
Advantech warrants to you, the original purchaser, that each of its products will be free from  
defects in materials and workmanship for two years from the date of purchase.  
This warranty does not apply to any products which have been repaired or altered by persons  
other than repair personnel authorized by Advantech, or which have been subject to misuse,  
abuse, accident or improper installation. Advantech assumes no liability under the terms of  
this warranty as a consequence of such events.  
Because of Advantechs high quality-control standards and rigorous testing, most of our  
customers never need to use our repair service. If an Advantech product is defective, it will be  
repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you  
will be billed according to the cost of replacement materials, service time and freight. Please  
consult your dealer for more details.  
If you think you have a defective product, follow these steps:  
1. Collect all the information about the problem encountered. (For example, CPU speed,  
Advantech products used, other hardware and software used, etc.) Note anything  
abnormal and list any onscreen messages you get when the problem occurs.  
2. Call your dealer and describe the problem. Please have your manual, product, and any  
helpful information readily available.  
3. If your product is diagnosed as defective, obtain an RMA (return merchandize  
authorization) number from your dealer. This allows us to process your return more  
quickly.  
4. Carefully pack the defective product, a fully-completed Repair and Replacement Order  
Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable  
container. A product returned without proof of the purchase date is not eligible for  
warranty service.  
5. Write the RMA number visibly on the outside of the package and ship it prepaid to your  
dealer.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Declaration of Conformity  
CE  
This product has passed the CE test for environmental specifications. Test conditions for  
passing included the equipment being operated within an industrial enclosure. In order to  
protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage,  
we strongly recommend the use of CE-compliant industrial enclosure products.  
FCC Class A  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instruction manual, may cause  
harmful interference to radio communications. Operation of this equipment in a residential  
area is likely to cause harmful interference in which case the user will be required to correct  
the interference at his own expense.  
Technical Support and Assistance  
Step 1. Visit the Advantech web site at www.advantech.com/support where you can find  
the latest information about the product.  
Step 2. Contact your distributor, sales representative, or Advantech’s customer service  
center for technical support if you need additional assistance. Please have the  
following information ready before you call:  
- Product name and serial number  
- Description of your peripheral attachments  
- Description of your software (operating system, version, application software,  
etc.)  
- A complete description of the problem  
- The exact wording of any error messages  
EKI-2525M & 2526M User Manual-V2.1-051507  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Instructions  
1. Read these safety instructions carefully.  
2. Keep this User's Manual for later reference.  
3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not  
use liquid or spray detergents for cleaning.  
4. For plug-in equipment, the power outlet socket must be located near the equipment and  
must be easily accessible.  
5. Keep this equipment away from humidity.  
6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may  
cause damage.  
7. The openings on the enclosure are for air convection. Protect the equipment from  
overheating. DO NOT COVER THE OPENINGS.  
8. Make sure the voltage of the power source is correct before connecting the equipment to  
the power outlet.  
9. Position the power cord so that people cannot step on it. Do not place anything over the  
power cord.  
10. All cautions and warnings on the equipment should be noted.  
11. If the equipment is not used for a long time, disconnect it from the power source to avoid  
damage by transient overvoltage.  
12. Never pour any liquid into an opening. This may cause fire or electrical shock.  
13. Never open the equipment. For safety reasons, the equipment should be opened only by  
qualified service personnel.  
14. If one of the following situations arises, get the equipment checked by service personnel:  
a. The power cord or plug is damaged.  
b. Liquid has penetrated into the equipment.  
c. The equipment has been exposed to moisture.  
d. The equipment does not work well, or you cannot get it to work according to the user's  
manual.  
e. The equipment has been dropped and damaged.  
f. The equipment has obvious signs of breakage.  
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE  
TEMPERATURE MAY GO BELOW -40к (-40л) OR ABOVE 85к (185л). THIS  
COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN  
CONTROLLED ENVIRONMENT.  
A
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precaution - Static Electricity  
Follow these simple precautions to protect yourself from harm and the products from damage.  
1. To avoid electrical shock, always disconnect the power from your PC chassis before you  
work on it. Don't touch any components on the CPU card or other cards while the PC is  
on.  
2. Disconnect power before making any configuration changes. The sudden rush of power  
as you connect a jumper or install a card may damage sensitive electronic components.  
EKI-2525M & 2526M User Manual-V2.1-051507  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Chapter 1 Overview ........................................... 2  
1.1 Introduction........................................................ 2  
1.1.1 High-Speed Transmissions.......................2  
1.1.2 Dual Power Input ......................................2  
1.1.3 Flexible Mounting......................................2  
1.1.4 Advanced Protection.................................2  
1.1.5 Wide Operating Temperature....................2  
1.1.6 Easy Troubleshooting ...............................2  
1.2 Features.............................................................3  
1.3 Specification ......................................................4  
1.4 Packing List .......................................................6  
1.5 Safety Precaution............................................... 6  
Chapter 2 Installation........................................ 8  
2.1 LED Indicators ...................................................8  
Table 2.1: EKI-2525M/2526M LED Definition........... 8  
2.2 Dimensions (units: mm) ..................................... 9  
Figure 2.1: Front View of EKI-2525M/2526M............ 9  
Figure 2.2: Side View of EKI-2525M/2526M ............10  
Figure 2.3: Rear View of EKI-2525M/2526M............11  
Figure 2.4: Top View of EKI-2525M/2526M.............12  
2.3 Mounting.......................................................... 13  
2.3.1 Wall mounting......................................... 13  
Figure 2.5: Combine the Metal Mounting Kit.............13  
2.3.2 DIN-rail Mounting.................................... 14  
Figure 2.6: Installation to DIN-rail Step 1 ..................14  
Figure 2.7: Installation to DIN-rail Step 2 ..................15  
2.4 Network Connection......................................... 16  
Figure 2.8: Pin Assignment of the Power Connector ..16  
2.5 Power Connection............................................ 17  
Figure 2.9: Pin Assignment of the Power Connector ..17  
Chapter 3 Troubleshooting ............................ 20  
Appendix A Pin Assignment & Wiring ........... 22  
Figure A.1: RJ-45 Pin Assignment.............................22  
Figure A.2: EIA/TIA-568B........................................22  
Figure A.2: EIA/TIA-568A........................................22  
vii  
Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EKI-2525M & 2526M User Manual-V2.1-051507  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Sections include:  
ò
ò
ò
ò
ò
Introduction  
Features  
Specifications  
Packing List  
Safety Precaution  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 Overview  
1.1 Introduction  
The EKI-2525M/2526M is a cost-effective solution and meets the high reliability  
requirements demanded by industrial applications.  
1.1.1  
High-Speed Transmissions  
The EKI-2525M/2526M is an industrial switch which provides you with one (EKI-2525M)  
or two (EKI-2526M) fiber port for your fiber optic cable to make a long-distance  
connection. The EKI-2525M or EKI-2526M includes a switch controller that can  
automatically sense transmission speeds (10/100 Mbps). The RJ-45 interface can also  
be auto-detected, so MDI or MDI-X is automatically selected and a crossover cable is  
not required. All Ethernet ports have memory buffers that support the store-and-  
forward mechanism. This assures that data is properly transmitted.  
1.1.2  
Dual Power Input  
EKI-2525M/2526M redundant power input design is with power reserve protection to  
prevent the switch device broken by wrong power wiring. When one of power input is  
fail, P-Fail LED will turn on and send an alarm through a relay output for notifying user.  
1.1.3  
Flexible Mounting  
EKI-2525M/2526M is extremely compact (37 x 140 x 95 mm) and can be mounted on a  
DIN-rail or a panel, so it is suitable for any space-constrained environment.  
1.1.4  
Advanced Protection  
EKI-2525M/2526M supports up to 3,000 VDC surge protection for power line, and also  
supports 4000V ESD for Ethernet ports. With these 2 strong protections, it can secure  
equipment against unregulated voltage and make systems safer and more reliable.  
Further, EKI-2525M/2526M provides currency overload protection with a resettable  
fuse to ensure that the device component won’t be damaged by overload current.  
1.1.5  
Wide Operating Temperature  
The operating temperature of the EKI-2525M/2526M is between -40 ~ 75 к (wide  
operating temperature model) or -10 ~ 60 к (standard model). With such a wide range,  
you can use the EKI-2525M/2526M in some of the harshest industrial environments  
that exist.  
1.1.6  
Easy Troubleshooting  
LED indicators make troubleshooting quick and easy. Each 10/100 Base-TX port has 2  
LEDs that display the link status, transmission speed and collision status. Also the  
three power indicators P1, P2 and P-Fail help you diagnose immediately.  
EKI-2525M & 2526M User Manual-V2.1-051507  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 Features  
Provides 4 x 10/100TX + 1 x 100FX (EKI-2525M) or 4 x 10/100TX + 2 x 100FX  
(EKI-2526M) Mbps Ethernet ports with RJ-45 connector  
Provides 2K (wide operating temp. model) or 1K (standard model) MAC address  
table  
TX ports Support full/half duplex flow control  
Supports store & forward transmission  
supports auto-negotiation  
Supports MDI/MDI-X auto-crossover  
Provides surge protection (EFT) 3,000 VDC for power line  
Supports 4,000 VDC ESD protection for Ethernet  
Supports +12 ~ 48 VDC power input  
Provides flexible mounting: DIN-rail, Wall Mounting  
Supports operating temperatures from -40 ~ 75 к (wide operating temperature  
model) or -10 ~ 60 к (standard model)  
3
Chapter1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3 Specification  
Communications  
IEEE 802.3, 802.3u, 802.3x  
10/100Base-TX, 100Base-FX  
Multi-Mode Fiber: 2KM  
(50/125Ӵ̀ʳ̑ʳ62.5/125Ӵm)  
UTP/STP up to 100 meters  
Up to 100 Mbps  
Compatibility  
LAN  
Transmission Distance  
Transmission Speed  
Interface  
4 x RJ-45  
Connectors  
1 x SC type 100M fiber (EKI-2525M)  
2 x SC type 100M fiber (EKI-2526M)  
6-pin removable screw terminal (power &  
relay)  
Unit: P1, P2, P-Fail  
TX port: Link/Active, Duplex/Collision  
LED Indicators  
Power  
0.9A@12VDC(25ʳк)  
EKI-2525M: 4.44 W  
EKI-2526M: 6.41 W  
2 x Unregulated +12 ~ 48 VDC  
1 Relay Output  
Current Overload Protection  
Power Consumption  
Power Input  
Fault Output  
Mechanism  
37 x 140 x 95 mm  
IP30, Metal shell with solid mounting kits  
DIN-rail, Wall  
Dimensions (WxHxD)  
Enclosure  
Mounting  
Protection  
4000 VDC  
3000 VDC  
Yes  
ESD (Ethernet)  
Surge (EFT for power)  
Power Reverse  
Environment  
-40~75ʳкʳʻ̊˼˷˸ʳ̂̃˸̅˴̇˼́˺ʳ̇˸̀̃˸̅˴̇̈̅˸ʳ̀̂˷˸˿ʼ  
Operating Temperature  
EKI-2525M & 2526M User Manual-V2.1-051507  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
-10~60ʳкʳʻ̆̇˴́˷˴̅˷ʳ̇˸̀̃˸̅˴̇̈̅˸ʳ̀̂˷˸˿ʼ  
5%~95% (non-condensing)  
-40~85ʳк  
Operating Humidity  
Storage Temperature  
Certifications  
UL, 60950-1, CAN/CSA-C22.2 No.60950  
U.S.A.: FCC Part 15 CISPR 22  
EU: EN55011, EN61000-6-4  
EN55022, Class A,  
Safety  
EMC  
EN61000-3-2/3  
EN55024  
IEC61000-4-2/3/4/5/6/8/11/12  
EN61000-6-2  
IEC60068-2-32  
IEC60068-2-27  
IEC60068-2-6  
Free Fall  
Shock  
Vibration  
5
Chapter1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 Packing List  
1 x EKI-2525M or 1 x EKI-2526M Industrial Ethernet Switch  
1 x eAutomation Industrial Communication CD-ROM with software, and User manual  
2 x Wall Mounting Bracket and Screws  
1 x DIN-rail Mounting Bracket and Screws  
1 x EKI-2525M/2526M Startup Manual  
1 x DC Jack Cable 2.0/150mm  
1.5 Safety Precaution  
Attention  
IF DC voltage is supplied by an external circuit, please use a protection device  
on the power supply input.  
EKI-2525M & 2526M User Manual-V2.1-051507  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Sections include:  
ò
ò
ò
ò
ò
LED Indicators  
Dimensions  
Mounting  
Network Connection  
Power Connection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Installation  
In this chapter, you will be given an overview of the EKI-2525M/2526M hardware  
installation procedures.  
2.1 LED Indicators  
There are few LEDs display the power status and network status located on the front  
panel of EKI-2525M/2526M, each of them has its own specific meaning as below table.  
Table 2.1: EKI-2525M/2526M LED Definition  
LED  
Color  
Description  
On  
Power input 1 is active  
P1  
Green  
Off  
Power input 1 is inactive  
On  
Power input 2 is active  
P2  
Green  
Red  
Off  
Power input 2 is inactive  
On  
Power input 1 or 2 is inactive  
Power input 1 and 2 are both active, or no power input  
Connected to network  
P-Fail  
Off  
On  
Link/Active  
(1~5 for EKI-2525M)  
(1~6 for EKI-2526M)  
Green  
Yellow  
Flashing  
Off  
Networking is active  
Not connected to network  
On  
Ethernet port full duplex  
Duplex/Collision  
(1~4)  
Flashing  
Off  
Collision of packets occurs  
Ethernet port half duplex or not connect to network  
EKI-2525M & 2526M User Manual-V2.1-051507  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Dimensions (units: mm)  
Figure 2.1: Front View of EKI-2525M/2526M  
9
Chapter2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2.2: Side View of EKI-2525M/2526M  
EKI-2525M & 2526M User Manual-V2.1-051507  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2.3: Rear View of EKI-2525M/2526M  
11  
Chapter2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Please refer to page 17 for pin assignment of power connector.  
Figure 2.4: Top View of EKI-2525M/2526M  
EKI-2525M & 2526M User Manual-V2.1-051507  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Mounting  
The EKI-2525M/2526M supports two mounting methods: DIN-rail & Wall.  
2.3.1  
Wall mounting  
EKI-2525M/2526M can be wall-mounted by using the included mounting kit. Then,  
hang on the EKI-2525M/2526M to the nails on the wall.  
First, use the screws included in the package to combine the EKI-2525M/2526M and  
metal mounting kit. And then you can install the device firmly via the components,  
please see Figure 2.5 as below.  
Figure 2.5: Combine the Metal Mounting Kit  
13  
Chapter2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.2  
DIN-rail Mounting  
You can also mount EKI-2525M/2526M on a standard DIN-rail by below steps.  
The DIN-rail kit is screwed on the industrial switch when out of factory. If the DIN-rail kit  
is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.  
First, hang the EKI-2525M/2526M to the DIN-rail with angle of inclination. See figure  
2.6.  
Figure 2.6: Installation to DIN-rail Step 1  
EKI-2525M & 2526M User Manual-V2.1-051507  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Then, let the device down straight to slide over the rail smoothly. See Figure 2.7  
Figure 2.7: Installation to DIN-rail Step 2  
15  
Chapter2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Network Connection  
The EKI-2525M or EKI-2526M has the SC type fiber port in multi mode (2Km). When  
you connect the fiber port to another one, please follow the below figure to connect it.  
Wrong connection will not allow the port to work normally.  
Figure 2.8: Pin Assignment of the Power Connector  
Attention  
This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam.  
The EKI-2525M and EKI-2526M both have 4 x RJ-45 ports that support connection to  
10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full duplex operation. EKI-  
2525M/2526M can be connected to other hubs or switches through a twisted-pair  
straight through the cable or a crossover cable up to 100m long. The connection can  
be made from any TX port of the EKI-2525M/2526M (MDI-X) to another hub or switch  
either MDI-X or uplink MDI port.  
The EKI-2525M/2526M supports auto-crossover to make networking more easy and  
flexible. You can connect any RJ-45 (MDI-X) station port on the switch to any device  
such as a switch, bridge or router.  
EKI-2525M & 2526M User Manual-V2.1-051507  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5 Power Connection  
The EKI-2525M/2526M supports dual +12 ~ 48 VDC power inputs and power-fail relay  
output.  
Figure 2.9: Pin Assignment of the Power Connector  
You can connect an alarm indicator, buzzer or other signaling equipment through the  
relay output. The relay opens if power input 1 or 2 fails ( “Open” means if you connect  
relay output with an LED, the light would be off).  
17  
Chapter2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EKI-2525M & 2526M User Manual-V2.1-051507  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 Troubleshooting  
1.  
Power Input  
Verify that is using the right power cord/adapter (+12~48 VDC), please don’t use the  
power adaptor with DC output voltage higher than 48V, or it will burn this converter  
down.  
2.  
Cable  
Select the proper UTP cable to construct user network. Please check that is using the  
right cable. Use Unshielded Twisted-Pair (UTP) or Shielded Twisted-Pair (STP) cable  
for RJ-45 connections: 100 Category 3, 4 or 5 cable for 10 Mbps connections or 100  
Category 5 cable for 100 Mbps connections. Also, be sure that the length of any  
twisted-pair connection does not exceed 100 meters (328 feet).  
Otherwise, use the 50/125 ~ 62.5µm fiber cable to connect the fiber port in multi-mode.  
3.  
Diagnosing LED Indicators  
The switch can be easily monitored through panel indicators, which describes common  
problems user may encounter and where user can find possible solutions, to assist in  
identifying.  
If the power indicator does not light up when the power cord is plugged in, user may  
have a problem with power cord. Then check for loose power connections, power  
losses or surges at power outlet. If user still cannot resolve the problem, contact the  
local dealer for assistance.  
If the Industrial switch LED indicators are normal and the connected cables are correct  
but the packets still cannot transmit, please check your system’s Ethernet devices  
configuration or status.  
EKI-2525M & 2526M User Manual-V2.1-051507  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pin Assignment & Wiring  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A Pin Assignment & Wiring  
It is suggested to adopt ELA/TIA as the wiring of the RJ-45.  
Figure A.1: RJ-45 Pin Assignment  
Figure A.2: EIA/TIA-568B  
Figure A.2: EIA/TIA-568A  
EKI-2525M & 2526M User Manual-V2.1-051507  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Tablet Accessory 800ab User Manual
ADC Network Card MM701G2 User Manual
Adesso Mouse AKB 220 User Manual
AEG Washer 48380 User Manual
AGFA Digital Camera DC 733s User Manual
Alloy Computer Products Network Card GL242201 User Manual
Audiovox Stereo Amplifier JPA460 User Manual
Avet Reels Fishing Equipment LX 6 3 User Manual
Barco Pet Fence R9841832 User Manual
Panel Television Elba 63 TD 61 100 MTUser Manual