Cooking Hob
ELECTROGAS
Index
GB
GB
English
Instructions for use
Installation, 4
Use, 4
Maintenance, 4
Instructions for the installater
Installation, 6
Gas connection, 6
Electrical connection, 6
User characteristics, 7
Assistance, 8
THIS APPLIANCE IS CONCEIVED FOR
DOMESTIC USE ONLY.THE MANUFACTURER
SHALL NOT IN ANY WAY BE HELD
RESPONSIBLE FOR WHATEVER INJURIES
OR DAMAGES ARE CAUSED BY INCORRECT
INSTALLATIONORBYUNSUITABLE,WRONG
OR ABSURD USE.
G320GIX
G3201LIX
Dear customer,
We thank you and con-gratulate you on your
choice. This new carefully de-signed product,
manu-facturedwiththehighestqualitymaterials,
has been carefully tested to satisfy all your
cooking demands.We would therefore request
you to read and follow these easy instructions
which will allow you to obtain ex-cellent results
right from the start. May we wish you all the
very best with your modern appliance!
THE MANUFACTURER
ꢀ
GB
Fig. 2
ꢂ
Instructions for the installer
Installation
GB
This appliance is not provided with a combu-stion
product discharge. It is recommended that it be
installed in sufficiently aerated places, in terms of the
laws in force. The quantity of air which is necessary for
combu-stion must not be below 2.0 m3/h for each kW of
installed power. See table of burner power.
ISO 7/1
ISO 228/1 (FR)
Fig. 3
Positioning (Fig. 2)
Electrical connection (Fig. 4)
The appliance can be fitted into a working area
as illustrated on the corresponding figure. Before
positioning the hob, fit the seal
Prior to carrying out the electrical connection, please
ensure that:
• the plant characteristics are such as to follow what is
indicated on the matrix plate placed at the bottom of
the working area;
• thattheplantisfittedwithanefficientearthconnection,
following the standards and law provisions in force.
The earth connection is compulsory in terms of the
law.
Should there be no cable and/or plug on the
equipment, use suitable absorption material for the
working temperature as well, as indicated on the matrix
plate. Under no circumstance must the cable reach a
temperature above 50°C of the ambient tempera-ture.
If connecting directly to the mains power supply,
fit a multi-pole switch of a suitable size for the rated
capacity with a clearance distance which completely
disconnects the power line under overvoltage category
III conditions, consistently with the rules of installation
(the yellow/green earth wir must not be interrupted).
The plug or omnipolar switch must be easily reached
on the installed equipment.
around the entire
X
periphery of the hole cut in the worktop.
Gas connection (Fig. 3)
Connect the appliance to the gas cylinder or to the
installation according to the prescribed standards
in force, and ensure beforehand, that the appliance
matches the type of gas available. Otherwise, see
“Adaptation to various types of gas”. Furthermore,
check that the feed pressure falls within the values
described on the table: “User chacteristics”.
Rigid/semi rigid metal connection Carry out the
connection with fittings and metal pipes (even flexible
pipes) so as to obtain counter stress the inner parts of
the appliance.
N.B. - when the installation has been carried out, check
the perfect sealing of the entire connection system, by
using a soapy solution.
Fig. 4
ꢃ
Toavoidallrisk,ifthepowercablebecomesdamaged,
it must only be replaced by the manufacturer,
by an authorised service centre, or by a qualified
electrician.
GB
wok C3 only
Adaptation to various types of gas (Fig. 5)
Should the appliance be pre-set for a different type of
gas than that available, proceed as follows:
• replace the injectors (Fig. 5) with the corresponding
type of gas to be used (see table “Uses
characteristics”).
• to adjust to the minimum, use a screwdriver on the
screw placed on the tap (Fig. 6) after turning the tap
to its minimum position. For LPG (butane/propane)
screw tight
Fig. 5
Fig. 6
USER CHARACTERISTICS
GAS BURNERS
feed
burner
ø injecTors TherMal capaciTy
Type
pressure mbar
noMinal
W
consuMpTion
norM.
1/100 mm
129
77
fast
3000
1000
3500
3000
1000
3500
286
95
natural gas
G20 20
auxiliary
wok 3
fast
141
87
333
218
73
liquefied gas G30/G31 28-30/37 auxiliary
wok 3
50
94
254
ꢄ
Assistance
Before contacting After-Sales Service:
GB
1. See if you can solve the problem yourself.
2. Switch the appliance on again to see if the problem
has been solved. if it has not, disconnect the
appliance from the power supply and wait for about
an hour before switching on again.
3. If the problem persists after this course of action,
contact After-Sales Service.
Specify:
• the nature of the fault,
• the model
• the service number (the number after the word
SERVICE on the rating plate on the rear of the
appliance)
• your full address,
• your telephone number and area code.
Never call on unauthorized technicians and always
refuse to purchase non-original spare parts.
The manufacturer declines all responsibility for possible inaccuracies contained in this pamphlet, due to printing or
copying errors.We reserve the right to make on our own products those changes to be considered necessary or useful,
without jeopardizing the essential characteristics.
ꢅ
Notes
ꢆ
|