Contents
Important notes..................................................................................................................................... 2
Declaration of Conformity............................................................................................................. 5
Disposal and recycling ................................................................................................................. 6
Mounting monitor base................................................................................................................. 8
Removing monitor base ............................................................................................................... 8
Connecting the monitor ................................................................................................................ 9
Operation of the monitor..................................................................................................................... 13
Switching the monitor on/off....................................................................................................... 13
Notes on power management .................................................................................................... 14
Changing the monitor settings.................................................................................................... 15
Monitor settings using the OSD menu........................................................................................ 16
Troubleshooting.................................................................................................................................. 21
Notes regarding the DIN EN ISO 13406-2 standard .......................................................................... 23
Technical data .................................................................................................................................... 24
VESA-DDC / CI 1.1-compatible VGA interface .......................................................................... 25
Preset operating modes ............................................................................................................. 25
Power supply plug ...................................................................................................................... 26
Monitor port DVI-D/DVI-I ............................................................................................................ 27
Pin assignment D-SUB............................................................................................................... 28
Pin assignment HDMI................................................................................................................. 28
S-Video port ............................................................................................................................... 29
A26361-K1118-Z120-1-7619, edition 3
Contents
A26361-K1118-Z120-1-7619
Introduction
Your new LCD (Liquid Crystal Display) monitor SCALEOVIEW H22-1W offers numerous features
and functions, for example:
●
●
●
TFT display (Thin Film Transistor; active matrix)
minimal space requirements thanks to slim casing
optimum ergonomic characteristics (totally distortion-free, excellent picture definition and colour
purity right into the corners)
●
●
●
●
●
high degree of brightness and good contrast
high resolution: SCALEOVIEW H22-1W (1680 x 1050)
size of the display area comparable to that of 24" CRT (Cathode Ray Tube) monitor
presentation of up to 16.7 million colours (in conjunction with an appropriate graphics card)
automatic scanning of horizontal frequencies from 30 to 83 kHz and refresh rates (vertical
frequencies) from 30 to 75 Hz (absolutely flicker-free)
●
●
digital screen controller with microprocessor for storing 49 different display modes
freely adjustable colour alignment for matching the screen colours to the colours of various
input and output devices
●
●
●
convenient operation via integrated OSD (On-Screen-display) menu
VESA-DDC compatibility
VESA-FPMPMI compatibility (Flat Panel Monitor Physical Mounting Interface) - mechanical
interface to swivel arm and wall bracket)
●
●
●
plug&play capability
power management for reducing power consumption when the computer is not in use
In normal screen mode (dark characters against a light background) the monitor satisfies the
ergonomic requirements for the GS symbol.
This operating manual contains important information you require to start up and run your LCD
monitor.
A graphics card (screen controller) with VGA interface , a digital graphics card with DVI,
HDMI interface or Video interface (Composite Video and S-Video) is required to control the
SCALEOVIEW H22-1W LCD monitor. The monitor processes the data supplied to it by the screen
controller. The screen controller/the associated driver software is responsible for setting the modes
(resolution and refresh rate).
When putting the monitor into operation for the first time, the screen display should be optimally
adapted to the screen controller used and adjusted in accordance with your needs (see the
"Changing the monitor settings" section in the "Operation of the monitor" chapter).
Target group
You don't need to be an "expert" to perform the operations described here. Do, however, read the
"Important notes" chapter in the operating manual of the computer and in this operating manual.
In the event of any problems occurring, please contact your sales outlet or our help desk.
A26361-K1118-Z120-1-7619, edition 3
1
SCALEOVIEW H22-1W
Notational conventions
The meanings of the symbols and fonts used in this manual are as follows:
Pay particular attention to text marked with this symbol. Failure to observe this warning
endangers your life, destroys the device, or may lead to loss of data.
!
Supplementary information, remarks, and tips follow this symbol.
i
►
Text which follows this symbol describes activities that must be performed in the order shown.
"Quotation marks" indicate names of chapters or terms.
This font indicates filenames and menu items.
This fontindicates screen outputs.
Additional information
Details of how you set the resolution and refresh rate are provided in the documentation on your
screen controller/the associated driver software.
Important notes
In this chapter you will find information regarding safety which is essential to take note of
with your monitor.
!
Safety notes
This device complies with the relevant safety regulations for data processing equipment, including
electronic office machines for use in an office environment. If you have any questions, contact your
sales outlet or our help desk.
●
●
●
The display surface of the LCD monitor is sensitive to pressure and scratches. You should
therefore be careful with the display surface so as to avoid lasting damage (Newton rings,
scratches).
If the device is brought into the installation site from a cold environment, condensation can
form. Before operating the device, wait until it is absolutely dry and has reached approximately
the same temperature as the installation site.
During installing and operating the device, please observe the instructions on environmental
conditions in the "Technical data" chapter as well as the instructions in the "Installing an
ergonomic video workstation" chapter.
●
●
To ensure sufficient ventilation, the intake and exhaust air openings of the monitor must never
be blocked.
The monitor automatically sets itself to a mains voltage in the range of 100 V to 240 V. Ensure
that the local mains voltage lies within these limits.
●
●
Ensure that the power socket on the device or the grounded mains outlet is freely accessible.
The ON/OFF switch does not disconnect the device from the mains voltage. To completely
disconnect the mains voltage, remove the power plug from the socket.
2
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
●
●
The monitor is equipped with a power cable that complies with safety standards.
Lay all cables so that nobody can stand on them or trip over them. When attaching the device,
observe the relevant notes in the "Connecting the monitor" chapter.
●
If you use a different data cable from the one supplied, ensure that it is adequately shielded.
CE conformance and optimum picture quality are guaranteed only if you use the data cables
supplied.
●
●
No data transfer cables should be connected or disconnected during a thunderstorm.
Make sure that no objects (e.g. jewellery chains, paper clips, etc.) or liquids get inside the
device (danger of electric shock, short circuit).
●
●
The device is not waterproof! Never immerse the device in water and protect it from spray
water (rain, sea water).
In emergencies (e.g. damaged casing, elements or cables, penetration of liquids or foreign
matter), switch off the unit, disconnect the power plug and contact your sales outlet or our help
desk.
●
The monitor must be disposed of in accordance with the local regulations for disposal of
special waste. The screen background lighting contains mercury. You must observe the
applicable handling and disposal safety regulations for fluorescent tubes.
●
●
Only qualified technicians should repair the device. Unauthorised opening and incorrect repair
may greatly endanger the user (electric shock, fire risk).
You may set only those resolutions and refresh rates specified in the "Technical data" chapter.
Otherwise you may damage your monitor. If you are in any doubt, contact your sales outlet or
our help desk.
●
Use a screen saver with moving images and activate the power management for your monitor
to prevent still images from "burning in".
●
●
If you operate the monitor with the swivel arm or wall bracket, it may not be turned by 180°.
We recommend that you place your device on an insensitive, non-slip surface. In view of the
multitude of different finishes and varnishes used on furniture, it is possible that the feet of the
device will mark the surface they stand on.
Power cable
To guarantee safe operation, use the cable supplied. Use the following guidelines if it is necessary to
replace the original cable set.
●
●
The female/male receptacles of the cord set must meet IEC60320/CEE-22 requirements.
The cable has to be HAR-certified or VDE-certified. The mark HAR or VDE will appear on the
outer sheath.
●
For devices which are mounted on a desk or table, type SVT or SJT cable sets may be used.
For devices which sit on the floor, only SJT type cable sets may be used.
●
●
The cable set must be selected according to the rated current for your device.
If necessary, replace the original power cable with a regular grounded 3-core mains lead.
A26361-K1118-Z120-1-7619, edition 3
3
SCALEOVIEW H22-1W
Transport
●
Transport the monitor with care and only in its original packaging or another corresponding
packaging fit to protect it against knocks and jolts.
●
Never drop the LCD monitor (danger of glass breakage).
Cleaning
●
●
●
●
●
●
Always pull out the power plug before you clean the monitor.
Do not clean any interior parts yourself, leave this job to a service technician.
Do not use any cleaning agents that contain abrasives or may corrode plastic.
Ensure that no liquid will run into the system.
Ensure that the ventilation areas of the monitor are free.
The display surface of the LCD monitor is sensitive to pressure and scratches. Clean it only
using a soft, slightly moistened cloth.
Wipe the monitor casing with a dry cloth. If the monitor is particularly dirty, use a cloth which has
been moistened in mild domestic detergent and then carefully wrung out.
CE marking
The shipped version of this device complies with the requirements of the EEC directives
89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Low voltage directive".
FCC Class B Compliance Statement
The following statement applies to the products covered in this manual, unless otherwise specified
herein. The statement for other products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a "Class B" digital device,
pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-
Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in strict
accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
●
●
●
Reorient or relocate the receiving antenna.
Increase the separation between equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
●
Consult the dealer or an experienced radio/TV technician for help.
4
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Fujitsu Siemens Computers GmbH is not responsible for any radio or television interference caused
by unauthorised modifications of this equipment or the substitution or attachment of connecting
cables and equipment other than those specified by Fujitsu Siemens Computers GmbH. The
correction of interferences caused by such unauthorised modification, substitution or attachment will
be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to any and all optional
peripheral or host devices. Failure to do so may violate FCC and ICES rules.
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Product name:
Colour LCD Monitor
Trade name:
Fujitsu Siemens Computers Inc.
SCALEOVIEW H22-1W
Model number(s):
Name of responsible party:
Fujitsu Siemens Computers Inc.
1250E. Arques Avenue
Sunnyvale, CA 94085
U.S.A.
Contact person:
Phone No.:
Fax No.:
Schroettle-Henning, Bernd
(408) 746-8256
(408) 746-8299
We, Fujitsu Siemens Computers Inc., hereby declare that the equipment bearing the trade name and
model number specified above was tested confirming to the applicable FCC Rules under the most
accurate measurement standards possible, and that all the necessary steps have been taken and
are in force to assure that production units of the same equipment will continue to comply with the
Commissions requirements.
Energy Star Guidelines
The Fujitsu Siemens LCD colour monitor SCALEOVIEW H22-1W is
designed to conserve electricity by dropping to less than 2 W when it goes
into standby, suspend and OFF mode. With this new power management
the monitor SCALEOVIEW H22-1W qualifies for the U.S. Environmental
Protection Agency's (EPA) Energy Star Computers award.
The EPA estimates that computer equipment uses 5 % percent of all business electricity and that
this is growing rapidly. If all desktop computers and peripherals enter a low-power mode when not in
use, the overall savings in electricity could amount to $ 2 thousand million annually. These savings
could also prevent the emission of 20 million tons of carbon dioxide into the atmosphere - the
equivalent of 5 million automobiles.
As an Energy Star Partner, Fujitsu Siemens Computers GmbH has determined that this product
meets the Energy Star guidelines for energy efficiency.
A26361-K1118-Z120-1-7619, edition 3
5
SCALEOVIEW H22-1W
Disposal and recycling
This device has been manufactured to the highest possible degree from materials which can be
recycled or disposed of in a manner that is not environmentally damaging. The device may be taken
back after use to be recycled, provided that it is returned in a condition that is the result of normal
use. Any components not reclaimed will be disposed of in an environmentally acceptable manner.
If you have any questions on disposal, please contact your local office, our help desk, or:
Germany
Belgium
Switzerland
Fujitsu Siemens Computers
GmbH
Remarketing und Recycling
D-33106 Paderborn
Tel.: +49 5251 / 81 80 10
Fax: +49 5251 / 81 80 15
RECUPEL
Boulevard Reyers, 80
B-1030 Brussels
Tel.: +32 2 / 706 86 16
Fax: +32 2 / 706 86 13
E-Mail: [email protected]
SWICO
Schweizerischer
Wirtschaftsverband der
Informations-,
Kommunikations- und
Organisationstechnik
A list of the SWICO
Acceptance places can be
found at:
Checking the contents of the consignment
The display surface of the LCD monitor is sensitive to pressure and scratches. Always
hold the device by the casing!
!
►
►
►
Unpack all the individual parts.
Check the delivery for damage incurred during transportation.
Check whether the delivery agrees with the details in the delivery note.
The complete LCD monitor package includes:
–
–
–
–
–
–
–
–
–
–
–
–
one monitor
one monitor base
one cover
one data cable (D-SUB)
one data cable (DVI-D)
one data cable (HDMI)
two audio cables
one USB cable for the computer
one power cable
one CD
one Warranty Booklet
one "Getting Started" manual
Should you discover that the delivery does not correspond to the delivery note, notify your local sales
outlet immediately.
We recommend that you keep the original packaging material. You may need the
packaging in the future if you need to transport your device.
i
6
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Installing an ergonomic video workstation
Before you set up your equipment, you should select a suitable position for working at the monitor.
Please observe the following advice when installing a video workstation.
2
1
1
Avoid glare from electric
lighting.
1 = Windows
1 = approx. 90° and more
2 = approx. 90°
Avoid direct and reflected glare.
Remember to maintain correct
posture.
1
0°
65°
30°
30°
60°
65°
2
2
Example layout of monitor,
keyboard and copy-holder
1 = Bearing surface for palms
of hands
1 = Preferable viewing sector
2 = Permissible viewing sector
2 = Reaching area for
frequently used equipment
Position the monitor for
distance to the monitor should
be approximately 50 cm.
Position the keyboard where it
is easiest to reach.
Keep ventilated areas clear.
i
Depending on the situation, the use of a swivel arm or wall bracket (VESA FPMPMI), are available
from specialised dealers, may be advisable. For this purpose the monitor base must be removed
beforehand as described in the "Mounting and removing the monitor base" chapter.
A26361-K1118-Z120-1-7619, edition 3
7
SCALEOVIEW H22-1W
Mounting and removing the monitor base
Mounting monitor base
When delivered the lower section of the monitor base is removed.
►
►
Push the lower section of the monitor base (2) in the upper section (1).
Fasten the screw (3).
Removing monitor base
Before you can use a swivel arm or a wall bracket, you must remove the entire monitor base.
►
Switch off the monitor and pull the power plug out of the power socket.
The display surface is susceptible to scratching!
!
►
Lay the monitor on its face on a soft surface.
8
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
►
►
Remove the cover (3) and disconnect all
cables.
Remove the two screws under the
covers (1 and 2).
You can now mount a swivel arm or a wall
bracket as per VESA FPMPMI with 100 mm
hole spacing.
For instructions on how to mount the swivel arm
or wall bracket, please see the documentation for
the swivel arm or wall bracket.
Connecting the monitor
Please take note of the safety information in the "Important notes" chapter.
!
CE conformance and optimum picture quality are guaranteed only if you use the data
cables supplied.
Do not cover the ventilation openings of the monitor.
The computer power plug must be pulled out!
►
Be sure that the monitor and the computer are switched off.
Connecting cables to the monitor
The monitor ports are protected by a cover.
►
Remove the cover.
A26361-K1118-Z120-1-7619, edition 3
9
SCALEOVIEW H22-1W
10
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
The data cables supplied have one 15-pin D-SUB connector (4) or one 24-pin DVI-D connector (2)
and one 19-pin HDMI connector (3) for connection to the monitor and to the computer.
►
Select the suitable data cable for your computer.
Digital graphics card with DVI /HDMI interface:
Graphics card with VGA interface:
DVI-D or HDMI connector
D-SUB connector
Information on the computer connections and interfaces is contained in the operating manual
for your computer.
►
Connect one of the connectors of the data cable to the D-SUB connector (4) or the DVI-D (2) or
HDMI (3) connector on the monitor and secure the plug-in connection by tightening the safety
screws.
The monitor automatically detects only the digital input when only one signal source is
connected. The video input (Video or S-Video) has to be selected upon the OSD-Menu.
i
The following devices can be connected to this monitor:
S-VIDEO (5) Connection for S-Video and audio input signals
e.g. for DVD player, video recorder, a film camera with S-Video
connection or a PC
Video (AV/CVBS) : Connection for AV video input signals
Yellow (6)
e.g. for DVD player, video recorder, film camera with video port or
gaming console
AUDIO
e.g. for DVD player, video recorder, film camera with video port,
gaming console, HDTV decoder or HDTV video recorder
red (right) (7)
white (left) (7)
PC AUDIO IN (8)
USB (10)
Connection for audio input signals (LINE IN)
e.g. for a PC
USB ports
to the PC
USB (13)
e.g. for mouse, keyboard, digital camera
►
If necessary, insert one plug of each audio cable in the AUDIO IN (8) sockets on the monitor
and make sure they are properly engaged.
Green: loudspeakers/headphones (11)
Pink: microphone (9) and (12)
A26361-K1118-Z120-1-7619, edition 3
11
SCALEOVIEW H22-1W
►
If necessary, insert one plug of the USB cable in the USB port (10) on the monitor and make
sure it is properly engaged.
►
►
Plug the power cable supplied into the power connector (1) of the monitor.
Mount the cover over the connections.
A lock (Kensington Lock) can be mounted in the security slot (14) to protect the monitor
from theft. A Kensington Lock is not included in the consignment of the monitor.
i
Connecting cables to the computer
Information on the computer connections and interfaces is contained in the operating manual for your
computer.
If your computer has two monitor ports ("onboard" screen controller and separate
graphics card), the monitor port for the separate graphics card is usually active.
i
►
Connect the data cable to the (active) monitor port on the computer and secure the plug-in
connection by tightening the safety screws.
►
►
►
Insert the other plug of the each audio cable in the audio ports of the computer.
Insert the other plug of the USB cable into a USB port of the computer.
Plug the connector of the mains cable provided into the monitor outlet of the computer or into a
properly earthed outlet and ensure a safe connection.
12
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
►
Plug the power connector of the computer into a properly grounded mains outlet.
When you start working with your monitor for the first time you should install the
appropriate graphics drivers for your application software. Details of how to do this are
provided in the documentation on your screen controller/the associated driver software.
i
Operation of the monitor
The monitor offers the following possibilities that enable it to be optimally adjusted for the respective
user and the respective situation.
Adjusting rake
The rake of the monitor can be adjusted by -5° (forward) and +20° (back) from its vertical position.
►
Grasp the monitor with both hands on the right and left edge of the casing and adjust it to the
desired rake.
Switching the monitor on/off
1 = Buttons for the OSD menu
(On-Screen-display)
2 = ON/OFF switch
3 = Power indicator
The ON/OFF switch (2) is used for switching the monitor on and off.
The power indicator (3) lights up blue when the monitor and computer are switched on. The power
indicator lights up orange when the monitor does not receive a video signal or is in the energy saving
mode. The power indicator goes off when the monitor is switched off.
A26361-K1118-Z120-1-7619, edition 3
13
SCALEOVIEW H22-1W
When you switch the computer system on, you must proceed in the following order:
►
►
First switch on the LCD monitor with the ON/OFF switch (2).
Then switch on the computer.
If your computer has a power management function (energy-saving mode), you should
read the "Notes on power management" section in this chapter.
i
Notes on power management
If your computer is equipped with power management, the monitor can support this function fully.
Here the monitor does not distinguish between the individual energy-saving modes of the computer
(standby mode, suspend mode and OFF mode), as it is capable of immediately switching into the
mode with the highest energy-saving effect.
Stage
Power indicator
Function
ON
Power-Saving Mode
lights up orange
lights up blue
the monitor is working
normally
the screen is dark
Power consumption
normal < 60 W
reduced to < 2 W
If your computer detects inactivity (no input) it sends an appropriate signal to the monitor to reduce
the power consumption (energy-saving mode). The power indicator of the monitor changes colour to
indicate the status change.
Once an input is made at the computer the screen contents are redrawn and full power is restored.
For detailed information on how energy-saving mode operates refer to the operating manual or
technical manual of the computer.
When the monitor is switched to the energy-saving mode by the power management
system a power consumption of up to 1 W is maintained to feed the circuit for redrawing
the screen contents.
i
To completely switch off the power consumption, switch off the computer or pull the plug of
the monitor power cable out of the monitor socket of the computer.
14
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Changing the monitor settings
When putting the monitor into operation for the first time, the screen display should be optimally
adapted to the screen controller used and adjusted in accordance with your needs.
Basic monitor settings with the CD supplied
If one of the operating systems Windows 95/98, Windows NT, Windows Me, Windows 2000,
Windows XP or OS/2 (with Windows emulation installed) is used, the basic monitor settings can be
set with the CD supplied.
►
►
Insert the supplied CD into the CD-ROM drive.
Open the Readme file on the CD and follow the instructions in the file.
Your monitor should now already be properly adjusted. If none of the above operating systems is
used or minor corrections are to be made to the screen display, then change the monitor settings
with the OSD menu.
Changing the monitor settings with the buttons of the control panel
1 = Buttons for the OSD menu
(On-Screen-display)
2 = ON/OFF switch with power indicator
Use the buttons of the control panel to make the following monitor settings directly while the OSD
menu is switched off.
Performing auto-adjustment of the monitor
►
Press the EXIT/AUTO button for approx. 1 second while the OSD menu is switched off.
The Auto Processing message is displayed.
Picture quality and position are set to optimum values for your system.
Selecting input signal (Analogue/Digital/HDMI/Video/S-Video)
►
Press the
/INPUT button for approx. 1 second for calling the Input select setting window.
5
►
Press the 6/
or 5/INPUT button to select the desired input (Analogue/Digital/HDMI/Video/
S-Video).
Activation/Deactivation of DDC-CI Function
Press the MODE button and 5/INPUT to deactivate or reactivate the DDC-CI Function.
►
Selecting colour optimisation (MODE)
►
Press the MODE button for calling the Mode setting window.
►
Press the or /INPUT button to choose the desired colour optimisation.
/
6
5
A26361-K1118-Z120-1-7619, edition 3
15
SCALEOVIEW H22-1W
The following settings are offered:
Optimal
Office
recommended color enhance mode setting by input
suitable and optimised for word processing
suitable and optimised for photo editing
suitable and optimised for videos
Photo
Video
Games
suitable and optimised for games
Activating/deactivating muting
Press the button to switch the sound off and on again.
►
6/
A message is displayed that the action has been performed.
Monitor settings using the OSD menu
With the buttons on the control panel, call up and use the integrated OSD (On-Screen display) menu.
The OSD menu is available in different languages. The English menu names are used in
the following description (default setting). With the OSD function Language in the OSD Setup
you can select another language.
i
To set the OSD menu, perform the following steps:
►
Press the SELECT/MENU button to activate the OSD menu.
The main menu appears on the screen (on the left-hand side) with icons for the setting functions.
The first symbol (Brightness/Contrast) is
highlighted. In the right-hand part of the display
the associated functions are shown.
►
If necessary, press the
button to mark another icon (e.g. Image
/
or
/INPUT
6
5
adjust).
►
Press the SELECT/MENU button to select
the highlighted icon.
In the video mode only Brightness and
Contrast can be set.
i
16
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
The corresponding setting window (here: Image Adjust) is displayed. The functions offered depend on
the mode in which the monitor is being used (e.g. in Video Mode, only Sharpness can be set).
PC Mode
Video Mode
The first function (H-Position) is highlighted.
►
►
If necessary, press the
button to mark another function.
/
or
/INPUT
6
5
Press the SELECT/MENU button to select
the highlighted function.
►
►
Press the
/
or
/INPUT button to
6
5
adjust the value for the selected function.
Press the EXIT/AUTO button to exit the
function.
►
If necessary, press the
/
or
/INPUT
6
5
button to mark another function or press the
EXIT/AUTO button to return to the main
menu.
All changes are stored automatically.
If you want to change other settings, select the corresponding function from the OSD main menu. All
possible adjustments of the main menu are described in the following.
A26361-K1118-Z120-1-7619, edition 3
17
SCALEOVIEW H22-1W
Adjusting the brightness and contrast
Calling the Brightness / Contrast setting window
Setting the brightness of the display
Brightness
Contrast
With this function you change the brightness of the background lighting.
Setting the contrast of the display
With this function you modify the contrast of bright colour tones.
Setting the brightness of the display
Black Level
Auto Level
With this function you modify the contrast of dark colour tones.
Setting the brightness of the display
With this function you can automatically set the contrast.
Press the SELECT/MENU button to activate the function.
If the contrast is set too high, bright surfaces can no longer be distinguished from very
bright surfaces. If the contrast is set too low, the maximum brightness will not be achieved.
i
Adjusting size and position
Calling the Image adjust setting window
Adjusting the horizontal position
H-Position
V-Position
Clock
With this function you move the picture to the left or to the right.
Adjusting the vertical position
With this function you move the picture up or down.
Setting synchronisation
With this function you adjust the picture width to eliminate vertical picture
disturbances.
Eliminating picture interference
Phase
With this function you fine-tune your monitor to eliminate picture interference.
Adjusting the picture quality in case of interpolation
Sharpness
With this function you set the sharpness of the interpolation filter. Thus the display
can be optimised for pictures or texts.
Adjusting the volume
Calling the Audio setting window
Setting the volume for playback with the integrated loudspeakers
Switching the loudspeakers off or on
Volume
Mute
Source
Selecting audio source for audio inputs (PC or video devices)
18
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Setting colour temperature and colours
Calling the Colour setting window. It can be set only in office mode.
Selecting the colour temperature
The "warmth" of the screen colours is set using the colour temperature. The colour
temperature is measured in K (= Kelvin). You can select from sRGB, 6500 K, 7500 K,
9300 K, Native and Custom Colour.
Native
= Original colour of the LCD display
= User-defined colours
Custom Colour
In the user-defined setting you can change the colour ratios of the basic colours
(red, green, blue) as required.
Setting display of the OSD menu
Calling the OSD Setup setting window
Setting language for the OSD menu
Language
With this function you select the language for the OSD menu. The following
languages are offered: English (default setting), French, Spanish, Italian, Swedish,
Dutch, Russian
Setting the horizontal position of the OSD menu
OSD
H-Position
With this function you move the OSD menu to the left or to the right.
Setting the vertical position of the OSD menu
OSD
V-Position
With this function you move the OSD menu up or down.
Setting the display duration of the OSD menu
OSD
Timeout
With this function you select a value from 10 to 120 seconds.
If the set time expires without a setting being made, the OSD menu is automatically
faded out.
Setting functions in the "Advanced" menu
Calling the Advanced setting window
Selecting input signal
Input Select
With this function you switch the monitor from the analogue to the digital mode or to
video mode and vice versa, when more signal sources are connected
The condition is that the graphic card used supports this function.
Displaying monitor data
Resolution
Notifier
The optimum resolution for the SCALEOVIEW H22-1W monitor is 1680 x 1050
pixels. With the function activated (On), a message appears on the screen after
approx. 30 seconds if a different resolution is set.
Change the resolution to 1680 x 1050 to achieve optimum picture quality. With the
function deactivated (Off), no message appears.
A26361-K1118-Z120-1-7619, edition 3
19
SCALEOVIEW H22-1W
Select colour optimisation
Colour
Enhance
This function allows you to select one of the following settings:
Optimal, Office, Photo, Video, Game
Office corresponds to a colour temperature of 6500 K.
If you select Photo, Video or Game, the preset values for colour temperature, hue
and saturation will be deactivated.
Activating the factory settings
Factory Recall
With this function all settings are reset to the factory settings without prompting for
confirmation.
Press the SELECT/MENU button to activate the function. The Auto Processing
message is displayed.
Displaying information
Calling the Information setting window
With this function the model designation, serial number, resolution, H/V frequency,
input signal and polarity of the synchronisation signal are displayed.
20
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Troubleshooting
Should an error occur, first check the following points. If the distortion is still not eliminated, the
monitor should, if possible, be checked on another computer.
If you are unable to solve the problem, please inform our help desk.
Having this problem?
Check the following points:
No screen display
(power indicator does not light)
►
►
Check whether the monitor is switched on.
Check whether the power cable on the monitor is
connected correctly.
►
►
►
Check whether the computer is switched on.
Check whether the computer is switched on.
No screen display
(power indicator lights)
Check whether the data cable for the monitor is
correctly attached to the monitor port on the computer.
►
►
►
►
Press any key on the computer keyboard – the
computer may be in energy saving mode.
Alter the brightness and/or contrast until you get a
picture.
Message:
Check whether the data cable for the monitor is
correctly attached to the monitor port on the computer.
No Signal
Check whether the computer is switched on.
Message:
The input signal (horizontal frequency and refresh rate) at
the displayed input does not correspond to the technical
monitor data.
Frequency out of range:
## kHz / ## Hz
►
Adjust the video frequency range using the computer
software (see documentation for your computer or
your graphics card).
Please change the display
mode to 1680 x 1050 with
60 Hz.
Message:
►
Set the resolution to 1680 x 1050 using the computer
software.
For best picture quality,
please change resolution to
1680 x 1050 .
SELECT: Disable EXIT: Clear
A26361-K1118-Z120-1-7619, edition 3
21
SCALEOVIEW H22-1W
Having this problem?
Check the following points:
Picture position not correct
The monitor recognises an undefined mode (see the
"Technical data" chapter).
►
Press the EXIT/AUTO button to perform the auto-
adjustment of the screen.
►
Set the picture position with the OSD menu (see the
"Operation of the monitor" chapter).
Picture is shaking
►
►
Check whether the data cable for the monitor is
correctly attached to the monitor port on the computer.
Press the EXIT/AUTO button to perform the auto-
adjustment of the screen.
Picture is wrongly adjusted
►
►
Press the SELECT/MENU button to activate the
function Factory Recall. The Auto Processing message
is displayed.
Picture disturbances (vertical lines)
Press the EXIT/AUTO button to perform the auto-
adjustment of the screen.
Picture disturbances
(horizontal lines, picture noise)
►
Press the EXIT/AUTO button to perform the auto-
adjustment of the screen.
The background lighting has a limited lifetime. If your
monitor display should become too dark, the background
lighting will have to be exchanged.
The screen becomes darker
►
Please contact our help desk.
22
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Notes regarding the DIN EN ISO 13406-2 standard
Permanently unlit or lit pixels
The standard of production techniques today cannot guarantee an absolutely fault-free screen
display. A few isolated constant lit or unlit pixels (picture elements) may be present. The maximum
permitted number of pixels faults is stipulated in the stringent international standard ISO 13406-2
(Class II).
Example:
A 22" flat-screen monitor with a resolution of 1680 x 1050 has 1680 x 1050 = 1764000 pixels. Each
pixel consists of three subpixels (red, green and blue), so there are almost 5.3 million subpixels in
total. In accordance with ISO 13406-2 (Class II), a maximum of 7 pixels and 10 subpixels may be
faulty.
Pixel
A pixel consists of 3 subpixels, normally red, green and blue. A pixel is the
smallest element that can be generated by complete functionality of the display.
Subpixel
Cluster
A subpixel is a separately addressable internal structure within a pixel that
enhances the pixel function.
A cluster contains two or more defective pixels or subpixels in a 5 x 5 pixel block.
A26361-K1118-Z120-1-7619, edition 3
23
SCALEOVIEW H22-1W
Technical data
Dimensions and weight (LCD monitor)
Visible diagonals:
Dot pitch:
56 cm
0.28 mm (H) x 0.28 mm (V)
473.76 mm x 296.1 mm
1680 x 1050
Screen size:
Maximal resolution:
Dimensions (W x H x D) incl.
monitor base:
513.72 mm x 444.79 mm x 219.82 mm
Dimensions box (W x H x D):
Weight with packaging:
Weight without packaging:
Accessories:
560 mm x 505 mm x 143 mm
7,6 kg
5,4 kg
Power cable (1.8 m)
D-SUB data cable (1.8 m)
DVI-D data cable (1.8 m)
HDMI data cable (1.5 m)
2 x audio cable (1.8 m)
USB cable (1.8 m)
Storable display modes:
49
Ports
PC input:
Analogue input (VGA/D-Sub)
Digital input (DVI-D/HDMI)
Video input:
RGB (15-pin D-SUB) + PC-Audio (3.5 mm socket)
DVI-D (24-pin)/HDMI (19-pin)
Video input
Composite (RCA) + Audio-L/R (RCA)
4-pins DIM + Audio-L/R (RCA)
S-Video input
Electrical data
Video:
analogue, positive, 0.7 Vpp, 75 Ω
digital: DVI-D / HDMI
Synchronisation:
Horizontal frequency:
Refresh rate:
Separate Sync. TTL, positive or negative
30 kHz .... 83 kHz (multi-scanning)
30 Hz .... 75 Hz
Maximum pixel rate:
Power supply:
165 MHz
switches automatically
100 V - 240 V, 50 Hz - 60 Hz ± 2 Hz, 1.5 A - 0.7 A
Total power consumption:
Sound output:
< 60 W
in normal mode
< 2 W (Standby mode)
4 W left; 4 W right
24
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Environmental conditions
Environment class 3K2, IEC 721
Rated range of operation:
Humidity:
15 °C .... 35 °C
20 % .... 85 %
Limit range of operation:
Humidity:
5 °C .... 35 °C
20 % .... 85 %
Condensation must be avoided.
VESA-DDC / CI 1.1-compatible VGA interface
Your monitor is equipped with a VESA-DDC-compatible VGA interface. VESA-DDC (Video
Electronics Standard Association, Display Data Channel) is used as the communications interface
between the monitor and the computer. If your computer is equipped with a VESA-DDC-compatible
and select the appropriate settings.
If the monitor SCALEOVIEW H22-1W is not yet displayed in the list of monitors, you can
select the following monitor instead:
i
Fujitsu Siemens: SCENICVIEW P19-1, SCENICVIEW P19-2 (Resolution: 1280 x 1024)
Preset operating modes
The picture position and size have been set to optimum values at the factory for the
operating modes listed above. Depending on the screen controller used, it may be
necessary to adjust the display position and size. In this case, you can change and save
the settings (see the "Operation of the monitor" chapter).
i
The following are the most frequently used of the preset operating modes:
SCALEOVIEW H22-1W
Horizontal frequency
Refresh rate
Screen resolution
720 x 400
640 x 480
640 x 480
800 x 600
800 x 600
1024 x 768
1024 x 768
1280 x 1024
1280 x 1024
1600 x 1200
1440 x 900
1680 x 1050
31.5 kHz
31.5 kHz
37.5 kHz
37.9 kHz
46.9 kHz
48.4 kHz
60.0 kHz
64.0 kHz
79.9 kHz
75.0 kHz
55.9 kHz
65.3 kHz
70 Hz
60 Hz
75 Hz
60 Hz
75 Hz
60 Hz
75 Hz
60 Hz
75 Hz
60 Hz
60 Hz
60 Hz
For ergonomic reasons, a screen resolution of 1680 x 1050 pixels is recommended. Because of the
technology used (active matrix) an LCD monitor provides a totally flicker-free picture even with a
refresh rate of 60 Hz.
A26361-K1118-Z120-1-7619, edition 3
25
SCALEOVIEW H22-1W
Video mode
Resolution
V-Freq H-Freq
[Hz] [kHz]
Pixel Rate HS-
[MHz] pol
VS-
pol
Remark
1
2
640 x 480p
60 31.469
25.175
N
N
N
NSTC
720 x 480i
720 x 480p
720 x 576i
60
60
50
50
50
50
60
60
15.734
31.469
31.250
31.250
37.500
37.500
45.150
45.150
27.000
27.000
27.000
27.000
74.250
74.250
74.250
74.250
N
N
N
N
P
P
P
P
All inputs
HDTV: Component,
DVI, HDMI
3
4
5
6
7
8
9
N
N
N
P
P
P
P
All inputs
HDTV: Component,
DVI, HDMI
720 x 576p
1280 x 720p
1280 x 720p
1280 x 720p
1280 x 720p
PC mode w/o overscan
HDTV: Component,
DVI
PC mode w/o overscan
HDTV: Component,
DVI
HDTV: Component,
DVI, HDMI
10
11
1920 x 1080i
1920 x 1080i
50
60
31.3
74.250
74.250
P
P
P
P
HDTV: Component,
DVI, HDMI
33.78
12
13
1920 x 1080p
1920 x 1080p
50
60
67.5
148.500
148.500
P
P
P
P
HDTV, DVI, HDMI
HDTV, DVI, HDMI.
56.25
Power supply plug
+12 V DC
0 V
26
A26361-K1118-Z120-1-7619, edition 3
SCALEOVIEW H22-1W
Monitor port DVI-D/DVI-I
C1 C2
C3 C4
1
9
C5
17
Pin Meaning
Pin Meaning
Pin Meaning
1
2
3
4
5
6
TMDS Data2-
11 TMDS Data 1/3 Shield
12 not connected
13 not connected
14 +5V Power
21 not connected
22 TMDS Clock Shield
23 TMDS Clock+
24 TMDS Clock-
TMDS Data2+
TMDS Data 2/4 Shield
not connected
not connected
DDC Clock
15 Earth
16 Hot Plug Detect
C1 Analogue R Video Out
(*)
7
8
9
DDC Data
17 TMDS Data0-
18 TMDS Data0+
C2 Analogue G Video Out
(*)
Analogue Vertical
Sync
C3 Analogue B Video Out
(*)
TMDS Data1-
19 TMDS Data 0/5 Shield
20 not connected
C4 Analogue H-Sync. (*)
10 TMDS Data1+
(*) = Not connected with DVI-D version
C5 Analogue Common
GND Return (*)
A26361-K1118-Z120-1-7619, edition 3
27
SCALEOVIEW H22-1W
Pin assignment D-SUB
1
5
6
10
11
15
Pin
1
Meaning
Video input red
Video input green
Video input blue
Earth
Pin
Meaning
+5 V (DDC)
Sync. earth
Earth
9
2
10
11
12
13
14
15
3
4
DDC-Data
H. sync
5
Earth
6
Red video earth
Green video earth
Blue video earth
V. sync
7
DDC Clock
8
Pin assignment HDMI
Pin
Meaning
Pin Meaning
1
3
TMDS Data2+
TMDS Data2-
2
4
TMDS Data2 Shield
TMDS Data1+
TMDS Data-
5
TMDS Data1 Shield
TMDS Data0+
TMDS Data0-
TMDS Clock Shield
CEC
6
7
8
TMDS Data0 Shield
TMDS Clock+
TMDS Clock-
9
10
12
14
11
13
Reserve (N.C on
Device)
15
17
19
SCL
16
18
SDA
DDC/CEC Ground
Hot Plug Detect
+5 V Power
28