Electrolux E36EC65ESS User Manual

Electric Drop-In Cooktop  
E36EC65ESS  
36" ELECTRIC DROP-IN COOKTOP  
Configuration  
5 Electric Elements  
FEATURES  
Black Ceramic Smoothtop Glass Surface  
Professional-Style Knobs with Digital Display  
Blue LED Indicator Light  
Yes  
5
Yes  
2
6" to 9" Dual Element – 1200W/2500W  
5" to 7" to 9" Expandable Element – 1000W/1800W/2700W  
6" Element – 1200W  
1
2
Spill Control Cooktop  
Yes  
Yes  
A.D.A. Compliant*  
ACCESSORIES  
Granite Countertop Installation Kit – PN# 903061-9010  
Optional  
SPECIFICATIONS  
Overall Exterior Dimensions –  
Width  
36-3/4"  
Depth  
21-1/2"  
Height  
4"  
Power Supply Location  
Amps@240/208 Volts  
Middle Rear  
42.0/36.5  
10.16/7.63  
Connected Load (kW Rating) @ 240/208 Volts  
Electrical – Single phase 3- or 4-wire cable, 120/240V or  
120/208V, 60Hz, fused on both sides of line with ground.  
Required  
Armored Electrical Cable  
Included  
No  
Approved for Single Oven Combination Installation**  
Approved for Downdraft Vent Combination Installation***  
Shipping Weight (Approx.)  
Yes  
50 Lbs.  
*When properly installed, meets the appliance standards in the Americans with Disabilities  
Act and the Architectural Barriers Act Accessibility Guidelines as published by the United  
States Access Board on June 23, 2004, as amended August 5, 2005.  
Professional-Style Knobs with  
Digital Display  
The large, professional-style control knobs  
provide precise control and convenient preset  
digital settings.  
** Not approved to be used over any Electrolux ICON® Single Wall Oven.  
***Approved to be used in combination with an Electrolux ICON® Downdraft Vent.  
NOTE: Always consult local and national electric codes. Refer to Product Installation Guide  
for detailed installation instructions on the web at electroluxicon.com.  
Specifications subject to change.  
Expandable Elements  
Flexible elements with up to 4,400 watts of  
power expand to fit virtually any pan size so  
you have the utmost versatility.  
Sleek Smoothtop Glass Design  
The smooth, glass design of the cooktop  
seamlessly integrates with your countertop  
for a polished, premium look, making it easy  
to clean.  
Blue LED Indicator Light  
A blue LED indicator light remains illuminated  
until the surface is cool to the touch.  
electroluxicon.com  
Drop-In Cooktop/Downdraft Vent  
Countertop Preparation  
Countertop Preparation for 30" & 36" Drop-In Cooktop/Downdraft Vent Installation  
Vertical noncombustible surface - rear wall  
B
Backsplash  
Top  
3
/
4"max.  
For detailed cooktop and  
downdraft vent installation  
specifications, refer to  
model-specific product  
page and installation  
guide on web  
29/16"  
231/4  
min.  
"
D*  
1
/
4"min.  
flat ledge  
C
Flush with  
back side of  
cabinet front  
E**  
* Overall flat ledge behind  
backside of cabinet front  
25"  
** Minimum flat surface required  
to fit top surface of cooktop  
and downdraft vent cap  
A
E30DD75ESS/30" Cooktop Cutout Dimensions  
30" Cooktops  
E36DD75ESS/36" Cooktop Cutout Dimensions  
A
B
C
D
E
36" Cooktops  
E36EC65ESS  
E36EC70FSS  
E36GC65ESS  
E36GC70FSS  
E36IC80ISS  
A
B
C
D
E
E30EC65ESS  
E30EC70FSS  
E30GC64ESS  
E30GC70FSS  
E30IC80ISS  
30" 273/4  
30" 273/4  
271/2 273/4  
281/2 273/4  
293/4 273/4  
"
"
"
"
20 3/8  
20 1/4  
19 7/8  
19 3/4  
201/2  
"
"
"
"
23 3/16" 24 3/16"  
231/16" 241/16"  
2211/16" 2311/16"  
22 9/16" 23 9/16"  
23 5/16" 24 5/16"  
36" 33 3/4  
36" 33 3/4  
33 3/4 33 3/4  
341/2 33 3/4  
36" 33 3/4  
"
"
"
"
20 3/8  
201/2  
19 7/8  
19 3/4  
201/2  
"
"
"
"
23 3/16" 24 3/16"  
235/16" 245/16"  
2211/16" 2311/16"  
22 9/16" 23 9/16"  
23 5/16" 24 5/16"  
"
"
"
"
"
"
"
"
"
25"(standard countertop)*  
4"max. backsplash thickness  
Countertop  
backsplash  
3
Cooktop Installation Note:  
/
To ensure proper installation, refer to model-specific installation  
guide on web for cooktop dimensions, cutout dimensions and  
cabinet requirements. Due to varying cooktop depths, tight fit  
is possible between cooktop and vent.  
1
/4"min. flat ledge  
213/16"  
21/8  
Countertop  
raised lip  
Downdraft  
chimney top  
"
Studwall  
Countertop Preparation Note:  
Be aware of areas of potential interference called out in  
illustration. Countertop with raised lip and/or backsplash may  
not allow enough flat area for proper installation, 2-13/16"  
of flat countertop required behind cooktop. No gap required  
between back of cooktop and front of downdraft trim piece.  
3"  
9/32"  
Cooktop  
115/16"  
Vent unit  
Back side of  
cabinet front  
Vertical noncombustible surface - rear wall  
231/4"min.  
213/16"  
*Standard 25" countertop depth may NOT be adequate for  
some cooktop/vent installations, especially with backsplash.  
Stiffener  
Drop-In Cooktop/Downdraft Vent  
Countertop Preparation Specifications  
For detailed Drop-In Cooktop installation, refer to model-specific product  
Amps @120 Volts = 8.0 Amps  
Vent unit outside of building only.  
Vent must be installed in vertical orientation only.  
1,600 CFM remote exhaust blower (PN# 5304444802)  
included with vent – shipped in separate box.  
Do not use flexible duct. Round duct instead of rectangular duct  
recommended, especially when elbows are required.  
When multiple elbows are necessary, ensure a minimum of 24" of  
straight duct between any two elbows.  
Thermal breaks such as short section of nonmetallic duct, should  
be used in areas of extreme cold.  
For most efficient airflow exhaust, use a straight run or as few elbows  
as possible.  
Cold weather installations should have additional backdraft damper  
installed.  
page and installation guide on web. Plan installation so that all required  
minimum clearances between cooktop, overhead cabinets and adjacent  
vertical walls are provided.  
Position cooktop/vent cutout so all required minimum clearances are met.  
Minimum flat countertop area must meet or exceed combined overall  
width and depth as shown. Standard 25" countertop depth may NOT be  
adequate for some cooktop/vent installations, especially with backsplash.  
Separate circuits required for cooktop and vent. (Refer to product-specific  
electrical specifications.)  
Always consult local and national electric and gas codes. Check local  
building codes for installation requirements, as they may vary per locale.  
Downdraft Vent Specifications  
For detailed Downdraft Vent installations, refer to model-specific  
product page and installation guide on web.  
Voltage Rating 120V/ 60Hz/15 Amps  
Connected Load (kW Rating) @120 Volts = 1.0kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire  
service with a separate ground wire. Appliance must be grounded  
for safe operation.)  
Installing a Downdraft Vent in combination with any gas cooking  
surface will affect optimum burner efficiency.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxicon.com for detailed instructions.  
Electrolux Major Appliances, N.A.  
High standards of quality at Electrolux Home Products, Inc. mean we are  
constantly working to improve our products. We reserve the right to change  
specifications or discontinue models without notice.  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-877-4electrolux (1-877-435-3287) electroluxicon.com  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca  
DIC_DDV_PREP 10/10 © 2010 Electrolux Home Products, Inc.  
Printed in the U.S.A.  

HP Hewlett Packard Hewlett Packard Computer Monitor LA1956X User Manual
Hotpoint 6344 User Manual
GE JGP321 User Manual
EnGenius Technologies SN 920 ULTRA User Manual
Electrolux 4071 User Manual
DeLonghi Cooktop DEF905E User Manual
CDA HVC60 User Manual
Asus ME 99 User Manual
ARM VERSION 1 2 User Manual
American Dynamics Tyco AD920A User Manual