Dell™ PowerEdge™ SC440 Systems
Hardware Owner’s Manual
w w w. d e l l . c o m | s u p p o r t . d e l l . c o m
Contents
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Accessing System Features During Startup .
10
11
Front-Panel Features and Indicators
Back-Panel Features and Indicators
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
13
Connecting External Devices .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
16
System Messages
.
.
.
.
2
Using the System Setup Program
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
Entering the System Setup Program .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
28
Exiting the System Setup Program.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Main Screen
.
.
28
Password Features.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
35
35
37
38
Using the System Password
Using the Admin Password .
Disabling a Forgotten Password .
Contents
3
3
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
41
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Inside the System
.
.
.
.
.
Opening the System
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
43
44
Removing an Insert on the Front Drive Bezel.
Replacing an Insert on the Front Drive Bezel.
Diskette Drive
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
44
45
Removing the Diskette Drive .
Installing a Diskette Drive.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
49
Installing an Optical or Tape Drive .
Hard Drives.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
52
.
.
.
.
.
.
.
.
.
.
Installing a Hard Drive
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
57
58
SAS Controller Expansion Card.
Memory.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
59
Memory Module Upgrade Kits .
.
System Only)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
60
60
Removing a Memory Module .
Installing a Memory Module .
Microprocessor
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
62
62
65
Removing the Processor .
Replacing the Processor .
4
Contents
Cooling Fans .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
65
67
Removing the Cooling Fans .
Replacing the Cooling Fans.
System Battery .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
67
68
Removing the System Battery
Installing the System Battery .
Power Supply
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
69
70
Removing the Power Supply .
Installing the Power Supply.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
71
72
Removing the Chassis Intrusion Switch
Installing the Chassis Intrusion Switch.
Bezel .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
73
74
Removing the Bezel .
Replacing the Bezel.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
75
76
Removing the I/O Panel Assembly .
Replacing the I/O Panel Assembly .
System Board.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
76
78
Installing the System Board.
4
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
79
Safety First—For You and Your System
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Checking the Equipment .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
79
81
81
.
.
.
.
.
.
.
.
Troubleshooting the Keyboard .
Troubleshooting the Mouse.
.
.
.
.
.
.
.
.
.
.
Troubleshooting Basic I/O Problems
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
82
82
82
Troubleshooting a Serial Port.
.
Troubleshooting a USB Device .
Contents
5
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
91
Troubleshooting a Hard Drive .
.
.
.
.
.
.
5
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
98
98
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Running the System Diagnostics
.
.
.
.
System Diagnostics Testing Options.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
99
99
Selecting Devices for Testing.
Viewing Information and Results .
6
Jumpers and Connectors
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
101
System Board Jumpers.
.
.
.
.
.
101
6
Contents
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
107
108
Online Services .
AutoTech Service .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
109
109
110
112
Product Information .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Returning Items for Warranty Repair or Credit
Before You Call.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Glossary
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
133
141
Index
.
.
.
Contents
7
8
Contents
About Your System
This section describes the physical, firmware, and software interface features that provide and ensure
the essential functioning of your system. The physical connectors on your system’s front and back
panels provide convenient connectivity and system expansion capability. The system firmware,
applications, and operating system monitor the system and component status and alert you when a
problem arises. System conditions can be reported by any of the following:
•
•
•
•
•
Front or back panel indicators
System messages
Warning messages
Diagnostics messages
Alert messages
This section describes each type of message, lists the possible causes, and provides steps to resolve
any problems indicated by a message. The system indicators and features are illustrated in this
section.
Other Information You May Need
CAUTION: The Product Information Guide provides important safety and regulatory information. Warranty
information may be included within this document or as a separate document.
•
•
•
•
•
•
The Getting Started Guide provides an overview of system features, setting up your system, and
technical specifications.
CDs included with your system provide documentation and tools for configuring and managing
your system.
Systems management software documentation describes the features, requirements, installation,
and basic operation of the software.
Operating system documentation describes how to install (if necessary), configure, and use the
operating system software.
Documentation for any components you purchased separately provides information to configure
and install these options.
Updates are sometimes included with the system to describe changes to the system, software,
and/or documentation.
NOTE: Always check for updates on support.dell.com and read the updates first because they often
supersede information in other documents.
About Your System
9
•
documentation or advanced technical reference material intended for experienced users or
technicians.
Accessing System Features During Startup
Table 1-1 describes keystrokes that may be entered during startup to access system features. If your
operating system begins to load before you enter the keystroke, allow the system to finish booting, and
then restart your system and try again.
Table 1-1. Keystrokes for Accessing System Features
Keystroke
<F2>
Description
Enters the System Setup program. See "Using the System Setup Program" on page 27.
<F10>
Opens the utility partition, allowing you to run the system diagnostics. See "Running the System
Diagnostics" on page 98.
<F11>
Enters the boot menu selection screen, allowing you to choose a boot device.
Initiates PXE boot.
<F12>
<Ctrl+C>
Option is displayed for some SAS controller expansion cards. Enters the SAS Configuration Utility,
which includes RAID configuration options. See your SAS adapter User’s Guide for more
information.
<Ctrl+S>
Option is displayed only if you have PXE support enabled through the System Setup Program (see
Table 2-1). This keystroke allows you to configure NIC settings for PXE boot. For more
information, see the documentation for your integrated NIC.
10
About Your System
Front-Panel Features and Indicators
Figure 1-1 shows the controls, indicators, and connectors located on the system's front panel. Table 1-2
provides component descriptions.
Figure 1-1. Front-Panel Features and Indicators
1
2
3
4
9
8
5
7
6
Table 1-2. Front-Panel Components
Item
Component
Icon
Description
1
upper 5.25-inch drive
bay
Holds an optical drive.
2
lower 5.25-inch drive
bay
Holds an optional optical or tape backup unit drive.
3
4
flex bay
Holds an optional diskette drive.
Indicates hard drive activity.
hard-drive activity
indicator
About Your System
11
Table 1-2. Front-Panel Components (continued)
Item
Component
Icon
Description
5
USB connectors (2)
Connects USB 2.0-compliant devices to the system.
6
power button
The power button controls the DC power supply output to the system.
NOTE: If you turn off the system using the power button and the system is
running an ACPI-compliant operating system, the system performs a
graceful shutdown before the power is turned off. If the system is not
running an ACPI-compliant operating system, the power is turned off
immediately after the power button is pressed.
7
power light
No light — The system is off.
Steady green — The system is powered on.
Blinking green — The system is in a low power state.
Blinking amber — The system is powering up.
• If the hard drive indicator is off, the power supply may need to be
replaced.
• If the hard drive indicator is on, the system board is faulty. Check the
diagnostic indicators to see if the specific problem is identified. See
"Diagnostic Lights" on page 15.
8
9
network link light
Lights when the system is linked to a network.
diagnostic lights (4)
Display light-pattern codes to assist in troubleshooting system
problems. See "Diagnostic Lights" on page 15
.
12
About Your System
Back-Panel Features and Indicators
Figure 1-2 shows the controls, indicators, and connectors located on the system's back panel.
Figure 1-2. Back-Panel Features and Indicators
1
2
3
4
5
6
7
1
4
7
voltage selection switch
USB connectors (5)
2
5
power connector
serial connector
3
6
NIC connector
video connector
I/O expansion-card slots (5)
Connecting External Devices
When connecting external devices to your system, follow these guidelines:
•
Most devices must be connected to a specific connector and device drivers must be installed before the
device operates properly. (Device drivers are normally included with your operating system software or
with the device itself.) See the documentation that accompanied the device for specific installation
and configuration instructions.
About Your System
13
•
Always attach an external device while your system and the device are turned off. Next, turn on any
external devices before turning on the system (unless the documentation for the device specifies
otherwise).
See "Using the System Setup Program" on page 27 for information about enabling, disabling, and
configuring I/O ports and connectors.
NIC Indicator Codes
The NIC on the back panel has an indicator that provides information on network activity and link
status. See Figure 1-3. Table 1-3 lists the NIC indicator codes.
Figure 1-3. NIC Indicators
1
2
1
link indicator
2
activity indicator
Table 1-3. NIC Indicator Codes
Indicator Type
Indicator Code
Description
Activity
Off
When off at the same time that the link indicator is off,
the NIC is not connected to the network or the NIC is
System Setup Program" on page 27.
Blinking
Off
Indicates that network data is being sent or received.
Link
When off at the same time that the activity indicator is
off, the NIC is not connected to the network or the NIC is
disabled in the System Setup program. See "Using the
System Setup Program" on page 27.
Yellow
Orange
Green
1000-Mbps connection
100-Mbps connection
10-Mbps connection
14
About Your System
Power Supply Indicators
The voltage selection switch on the back panel of the system allows you to select one of two primary
voltage inputs. Ensure that the switch is set to the proper voltage according to Table 1-4.
Table 1-4. Voltage Selection Switch
If your power source is: The voltage selection switch should be set to:
110 V
220 V
115
230
For information on system power requirements, see "Technical Specifications" in your Getting Started
Guide.
Diagnostic Lights
The four diagnostic indicator lights on the system front panel display error codes during system startup.
Table 1-5 lists the causes and possible corrective actions associated with these codes. A highlighted circle
indicates the light is on; a non-highlighted circle indicates the light is off.
NOTE: Once the system completes POST, all diagnostic lights will be OFF.
Table 1-5. Diagnostic Indicator Codes
Code
Causes
Corrective Action
The computer is in a
Plug the computer into a working electrical
normal off condition or a outlet and press the power button.
possible pre-BIOS failure
has occurred.
The diagnostic lights are
not lit after the system
successfully boots to the
operating system.
page 95.
Memory failure.
See "Troubleshooting System Memory" on
page 87.
Possible expansion card See "Troubleshooting Expansion Cards" on
failure. page 93.
About Your System
15
Table 1-5. Diagnostic Indicator Codes (continued)
Code
Causes
Possible video failure.
See "Getting Help" on page 107.
Diskette drive or hard
drive failure.
Ensure that the diskette drive and hard drive
are properly connected. See "Hard Drives" on
system.
Possible USB failure.
page 82.
No memory modules
detected.
page 87.
System board failure.
Memory configuration
error.
page 87.
Possible system board
resource and/or system
board hardware failure.
See "Getting Help" on page 107.
Possible system resource See "Troubleshooting IRQ Assignment
configuration error.
Conflicts" on page 80. If the problem persists,
see "Getting Help" on page 107.
Other failure.
Ensure that the diskette drive, optical drive,
and hard drives are properly connected. See
"Troubleshooting Your System" on page 79 for
the appropriate drive installed in your system.
If the problem persists, see "Getting Help" on
page 107.
System Messages
System messages appear on the screen to notify you of a possible problem with the system. Table 1-6 lists
the system messages that can occur and the probable cause and corrective action for each message.
NOTE: If you receive a system message that is not listed in Table 1-6, check the documentation for the application
that is running when the message appears or the operating system's documentation for an explanation of the
message and recommended action.
16
About Your System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Table 1-6. System Messages
Message
Causes
Corrective Actions
A filename cannot contain
any of the following
characters:
Do not use these characters in filenames.
\ / : * ? “ < > |
A required .DLL file was
not found
open is missing an essential file.
application.
See the application’s documentation for
installation instructions.
Alert! CPU fan not
detected
The processor cooling fan is faulty or Ensure that the processor cooling fan is
the fan assembly is not installed
correctly.
System Cooling Problems" on page 86.
Alert! Previous reboot was
due to voltage regulator
failure
Alert! System battery
voltage is low
"Troubleshooting the System Battery" on
page 85.
One or more memory modules might See "Troubleshooting System Memory"
Alert! Unable to initial-
ize all installed memory
be faulty or improperly seated.
on page 87.
If the problem persists, see "Getting
Help" on page 107.
Alert! Card-cage fan
failure.
A card-cage fan is not detected during See "Troubleshooting System Cooling
POST. The system will halt at the
<F1>/<F2> prompt even if
Keyboard Errors Report option is
disabled in the System Setup
program.
Problems" on page 86.
Alert! Chipset heat sink
not detected.
Ensure heat sink and shroud assembly
are properly attached. See Figure 3-15.
Alert! Cover was
previously removed.
The system was opened.
Information only. To reset the chassis
intrusion switch, see "Using the System
Setup Program" on page 27.
About Your System
17
Table 1-6. System Messages (continued)
Message
Causes
Alert! CPU fan failure.
The processor cooling fan is faulty or Ensure that the processor cooling shroud
the fan assembly is not installed
correctly.
is properly installed. See
"Troubleshooting System Cooling
Problems" on page 86 and
"Microprocessor" on page 62.
Alert! Error initializing The system encountered a problem
See "Troubleshooting Expansion Cards"
on page 93.
PCI Express slot n (or
bridge).
while trying to configure a PCIe
expansion card.
Alert! Incompatible
processor detected.
Use only Dell supported processors. See
the Getting Started Guide for a list of
supported processors.
Alert! OS Install Mode
enabled. Amount of
available memory limited
to 256MB.
The OS Install Mode option in the
System Setup program is set to On.
This limits the amount of available
memory to 256 MB because some
After the operating system is installed,
enter the System Setup program and set
the OS Install Mode option to Off. See
"Using the System Setup Program" on
operating systems will not complete page 27.
installation with more than 2 GB of
system memory.
Alert! Previous fan
failure.
The fan caused errors the last time the Ensure that nothing is blocking the
system was used.
airflow vents and that all fans are
properly installed and operating
correctly. See "Troubleshooting System
Cooling Problems" on page 86.
Alert! Previous attempts
at booting this system
The system failed to complete the
boot routine three consecutive times
See "Getting Help" on page 107.
have failed at checkpoint for the same error.
[nnnn]. For help in
resolving this problem,
please note this
checkpoint and contact
Dell Technical Support.
Alert! Previous Processor The processor overheated the last
Ensure that nothing is blocking the
airflow vents and that all fans are
properly installed and operating
correctly. Also, ensure that the processor
heat sink is properly installed. See
"Microprocessor" on page 62.
Thermal Failure
time the system was used.
18
About Your System
Table 1-6. System Messages (continued)
Message
Causes
Alert! Previous Shutdown
Due to Thermal Event
The processor or hard drive
overheated the last time the system
was used.
Ensure that nothing is blocking the
airflow vents and that all fans are
processor heat sink is properly installed.
See "Microprocessor" on page 62.
Alert! Uncorrectable
Memory Error Previously
Detected... Address
be improperly seated or faulty, or the on page 87.
system board may be faulty.
If the problem persists, see "Getting
XXXXXXXXH, Device DIMM_Y
Help" on page 107.
Attachment failed to
respond
The diskette or hard-drive controller See "Troubleshooting a Diskette Drive"
cannot send data to the associated
drive.
Bad command or file name
Ensure that you have spelled the
command correctly, have put spaces in
the proper place, and have used the
correct pathname.
Bad error-correction code The diskette or hard-drive controller See "Troubleshooting a Diskette Drive"
(ECC) on disk read detected an uncorrectable read error. on page 89 or "Troubleshooting a Hard
Drive" on page 91.
bb/dd/f: Error allocating The system encountered a problem
If the device number points to an
IRQ for PCI Device
while trying to configure an expansion expansion card, the card can be removed.
card or integrated on-board devices.
See "Troubleshooting Expansion Cards"
on page 93.
bb/dd/f: Error allocating
I/O BAR for PCI Device
If the device number points to a an on-
board device, disable the device. See
"Using the System Setup Program" on
page 27.
bb/dd/f: Error allocating
Mem BAR for PCI Device
bb/dd/f: Error allocating
PMem BAR for PCI Device
bb/dd/f: Error allocating
UMB for PCI Device
NOTE: bbis the bus number, ddis the
device number, and fis the function
number. All numbers are hexadecimal.
Controller has failed
The hard drive or the associated
controller is defective.
See "Troubleshooting a Hard Drive" on
page 91.
About Your System
19
Table 1-6. System Messages (continued)
Message
Causes
The diskette drive or hard drive
cannot read the data.
Corrective Actions
Data error
For the operating system, run the
appropriate utility to check the file
structure of the diskette drive or hard
drive. See your operating system
Decreasing available
memory
One or more memory modules might Reinstall the memory modules and, if
be faulty or improperly seated.
necessary, replace them. See
page 87.
Diskette drive 0 seek
failure
A cable might be loose or the system See "Troubleshooting a Diskette Drive"
match the hardware configuration.
Diskette read failure
The diskette might be defective, or a If the diskette-drive indicator turns on,
cable might be loose.
try a different disk. See "Troubleshooting
a Diskette Drive" on page 89.
Diskette subsystem reset
failed
The diskette drive controller might be Run the system diagnostics. See
faulty.
"Running the System Diagnostics" on
page 98.
Diskette write protected
The diskette is write-protected.
No diskette is in the drive.
Slide the write-protect notch to the open
position.
Drive not ready
Insert a diskette in the drive.
Error auto-sensing primary
master hard disk drive
See "Troubleshooting a Hard Drive" on
page 91.
Error auto-sensing primary
slave hard disk drive
Error auto-sensing
secondary master hard disk
drive
Error auto-sensing
secondary slave hard disk
drive
Floppy diskette seek
failure
A diskette drive is not connected but See "Troubleshooting a Diskette Drive"
is enabled in the BIOS setup menu.
The diskette in the drive is faulty.
on page 89.
Gate A20 failure
Faulty keyboard controller (faulty
system board).
See "Getting Help" on page 107.
20
About Your System
Table 1-6. System Messages (continued)
Message
Causes
General failure
The operating system is unable to
carry out the command.
This message is usually followed by
specific information. Take the
appropriate action to resolve the
problem.
Hard-disk configuration
error
The hard drive failed initialization.
Run the system diagnostics. See
"Running the System Diagnostics" on
page 97. Also, see "Troubleshooting a
Hard Drive" on page 91.
Hard-disk controller
failure
Hard-disk drive failure
Drive x not found: Serial
(or Parallel) ATA, SATA-
(or PATA-)n
Run the system diagnostics. See
"Running the System Diagnostics" on
page 97. Also, see "Troubleshooting a
Hard Drive" on page 91.
NOTE: xis the drive number (0-6)
and nis SATA0-3 or PATA0-1.
Insert bootable media
from a nonbootable diskette or CD.
Invalid configuration
information - please run
SETUP program
The system configuration information Enter the System Setup program and
does not match the hardware
configuration.
correct the system configuration
information. See "Using the System
Setup Program" on page 27.
Keyboard Controller
Failure
A cable or connector might be loose, See "Troubleshooting the Keyboard" on
or the keyboard or keyboard/mouse
controller might be faulty.
page 81.
Keyboard Stuck Key Failure
Keyboard failure
Keyboard fuse has failed.
See "Troubleshooting the Keyboard" on
page 81.
Memory address line
A memory module might be faulty or Reinstall the memory modules and, if
failure at address, read
value expecting value
improperly seated.
necessary, replace them. See
"Troubleshooting System Memory" on
page 87.
Memory allocation error
The software you are attempting to
Turn off the system, wait 30 seconds,
run is conflicting with the operating restart the system, and then try to run
system, another program, or a utility. the program again. If the error message
appears again, see the software
documentation for additional
troubleshooting suggestions.
About Your System
21
Table 1-6. System Messages (continued)
Message
Causes
Corrective Actions
Memory data line failure
at address, read value
expecting value
A memory module might be faulty or Reinstall the memory modules and, if
improperly seated.
necessary, replace them. See
"Troubleshooting System Memory" on
page 87.
Memory double word logic
failure at address, read
value expecting value
Memory odd/even logic
failure at address, read
value expecting value
Memory write/read failure
at address, read value
expecting value
Memory size in CMOS
invalid
The amount of memory recorded in Restart the system. If the error message
the system configuration information appears again, see "Troubleshooting
does not match the memory installed System Memory" on page 87. If the
in the system.
problem persists, see "Getting Help" on
page 107.
Memory type or speed is not
supported on this system.
Please refer to system
documentation for support
memory configurations.
See "Troubleshooting System Memory"
on page 87.
NIC failure.
See "Troubleshooting a NIC" on page 83.
No boot device available
The system cannot find the diskette or If the diskette drive is your boot device,
hard drive.
ensure that a bootable disk is in the
drive.
If the hard drive is your boot device,
ensure that the hard drive is installed,
the interface cable is properly connected,
and the hard drive is partitioned as a
boot device.
Enter the System Setup program and
verify the boot sequence information.
See "Using the System Setup Program"
on page 27.
22
About Your System
Table 1-6. System Messages (continued)
Message
Causes
Corrective Actions
No boot sector on
hard-disk drive
The system configuration information Enter the System Setup program and
in the System Setup program might verify the system configuration
be incorrect.
information for the hard drive. See
"Using the System Setup Program" on
page 27.
If the message continues to appear after
verifying the information in the System
Setup program, the operating system
might have been corrupted. Reinstall the
operating system. See your operating
system documentation for reinstallation
information.
No timer tick interrupt
A chip on the system board might be Run the system diagnostics. See
malfunctioning.
page 97.
Non-system disk or disk
error
The diskette in the diskette drive or
your hard drive does not have a
bootable operating system installed
on it.
Replace the diskette with one that has a
bootable operating system or remove the
If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 89 or "Troubleshooting a Hard
Drive" on page 91.
If the problem persists, see "Getting
Help" on page 107.
Not a boot diskette
The operating system is trying to boot Insert a diskette that has a bootable
from a diskette that does not have a
bootable operating system installed
on it.
operating system.
Not enough memory or
resources. Close some
programs and try again.
You have too many programs open.
Close all windows and open the program
that you want to use. In some cases, you
might have to restart your system to
restore system resources. If so, try
opening the program that you want to
use first
See "Troubleshooting System Memory"
on page 87. If the problem persists, see
"Getting Help" on page 107.
Mixing ECC and non-ECC
DIMMs is not supported on
this platform
About Your System
23
Table 1-6. System Messages (continued)
Message
Causes
Corrective Actions
Operating system not found
See "Troubleshooting a Hard Drive" on
Please connect USB
keyboard/mouse to USB
ports on the back of the
computer
The keyboard and/or mouse is not
properly connected.
page 82.
Plug and play
configuration error
An attached device is improperly
configured.
See "Troubleshooting Your System" on
page 79.
Read fault
The operating system cannot read
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
Requested sector not found The operating system cannot read
from the diskette or hard drive, the
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
system could not find a particular
sector on the disk, or the requested
sector is defective.
Reset failed
The disk reset operation failed.
See "Troubleshooting a Diskette Drive"
Sector not found
Seek error
A faulty diskette drive or hard drive. See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
Shutdown failure
A chip on the system board might be Run the system diagnostics. See
malfunctioning.
"Running the System Diagnostics" on
page 97.
The amount of system
memory has changed
Memory has been added or removed, If memory has been added or removed,
or a memory module may be faulty.
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" on page 87.
The file being copied is
too large for the
destination drive.
The file that you are trying to copy is Try increasing disk space on the
too large to fit on the disk. destination drive by deleting
unnecessary files.
24
About Your System
Table 1-6. System Messages (continued)
Message
Causes
Time-of-day clock stopped The battery might be faulty.
See "Troubleshooting the System
Battery" on page 85.
Time-of-day not set
The time or date stored in the System Enter the System Setup program and
Setup program does not match the
system clock.
correct the Date and Time options. See
"Using the System Setup Program" on
page 27. If the problem persists, see
page 85.
Timer chip counter 2
failed
malfunctioning.
page 97.
Unexpected interrupt in
protected mode
Run the system diagnostics. See
"Running the System Diagnostics" on
page 97.
Write fault
The operating system cannot write to See "Troubleshooting a Diskette Drive"
the diskette drive or hard drive.
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
Write fault on selected
drive
<drive letter>:\ is not
accessible. The device is diskette.
The diskette drive cannot read the
Insert a diskette into the drive or replace
the existing diskette, and try again.
not ready.
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system
continues a task. For example, before you format a diskette, a message will warn you that you may lose all
data on the diskette. Warning messages usually interrupt the task and require you to respond by typing y
(yes) or n(no).
NOTE: Warning messages are generated by either the application or the operating system. For more information,
see the documentation that accompanied the operating system or application.
About Your System
25
Diagnostics Messages
When you run system diagnostics, an error message may result. Diagnostic error messages are not
covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help" on
page 107, and then follow the instructions in that section for obtaining technical assistance.
Alert Messages
Systems management software generates alert messages for your system. Alert messages include
information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For
more information, see the systems management software documentation.
26
About Your System
Using the System Setup Program
After you set up your system, run the System Setup program to familiarize yourself with your system
configuration and optional settings. Record the information for future reference.
You can use the System Setup program to:
•
•
•
•
Change the system configuration stored in NVRAM after you add, change, or remove hardware
Set or change user-selectable options—for example, the time or date
Enable or disable integrated devices
Correct discrepancies between the installed hardware and configuration settings
Entering the System Setup Program
During System Setup
1
2
Turn on or restart your system.
Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting,
and then restart your system and try again.
system.
Responding to Error Messages
You can enter the System Setup program by responding to certain error messages. If an error message
appears while the system is booting, make a note of the message. Before entering the System Setup
program, see "System Messages" on page 16 for an explanation of the message and suggestions for
correcting errors.
NOTE: After installing a memory upgrade, it is normal for your system to send a message the first time you
start your system.
Navigating the System Setup Program
Table 2-1 lists the keys that you use to view or change information on the System Setup screens, and to
exit the program.
Using the System Setup Program
27
Table 2-1. System Setup Program Navigation Keys
Keys
Action
Up arrow and down arrow
Left arrow and right arrow
<+> and <–> keys
<Enter>
Moves to the previous or next field
Moves left or right in a field
Opens and closes submenus
Allows you to view the details for or modify an option,
or allows you to confirm your setting change and moves
the cursor back to the option menu
<Esc>
Either moves your cursor back to the option menu
without modifying an option, or opens the System
Setup Exit screen
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the
system.
Exiting the System Setup Program
If you have made no changes in the BIOS, the Exit screen displays the following options after you press
<Esc> to exit the System Setup program:
•
•
Remain in Setup
Exit
If you have made changes in the BIOS, the Exit screen displays the following options after you press <Esc>
to exit the System Setup program:
•
•
•
Remain in Setup
Save/Exit
System Setup Options
Main Screen
Figure 2-1 shows an example of the main screen.
28
Using the System Setup Program
Figure 2-1. Main System Setup Program Screen
Table 2-2 through Table 2-9 lists the options and descriptions for each group of information fields that
appear on the main System Setup program screen.
NOTE: The System Setup program defaults are listed under their respective options, where applicable.
Table 2-2. System Options
Option
Description
System Info
Displays the System name, BIOS Version number, BIOS Date, Service Tag,
Express Service Code, and Asset Tag
.
Processor Info
Displays the following information for the processor installed in the system:
Processor Type Processor Clock Speed Processor Bus Speed Processor
Cache Size, Processor ID number, whether the processor is Multiple Core
Capable, or Hyperthreading Capable, and if the processor has 64-bit
Technology
,
,
,
.
Using the System Setup Program
29
Table 2-2. System Options (continued)
Option
Description
Displays the amount of Installed Memory Memory Speed, Memory
Memory Info
,
Channel Mode, and a description of the Memory Technology. This option
also displays a table that describes the memory size, whether the memory
module is ECC capable, single or dual rank, type, and organization for each
DIMM socket.
PCI Info
Displays the types of cards that are installed in the PCI slots, if applicable.
Resets the system’s internal calendar and clock.
Date/Time
Boot Sequence
(Diskette drive default)
Determines the order in which the system searches for boot devices during
system startup. Available options can include the diskette drive, CD drive,
hard drives, and USB devices.
Table 2-3. Drive Options
Option
Description
Diskette Drive
(Internal default)
Enables and disables the diskette drives and sets read permission for the
internal diskette drive. Off disables all diskette drives. USB disables the
internal diskette drive and enables a USB drive if the USB controller is
enabled and a USB drive is connected. Internal enables the internal
diskette drive. Read Only enables the internal drive controller and allows
the internal diskette drive read-only permission.
NOTE: Diskette drives are optional and may not be part of your system.
SATA0-3
Enables or disables a Serial Advanced Technology Attachment (SATA)
device (such as hard drive, CD drive, or DVD drive). Off disables the
interface so that the device cannot be used. On enables the interface so
that the device can be used.
Displays the Controller type, Port number the drive is using, Drive ID
number, Capacity, whether the drive is controlled by the BIOS, and Link
Speed.
PATA0-1
Enables or disables a Parallel Advanced Technology Attachment device
(such as hard drive or IDE drive). Off disables the interface so that the
device cannot be used. On enables the interface so that the device can be
used.
Displays the Controller type, Port number the drive is using, Drive ID
number, Capacity, whether the drive is controlled by the BIOS, and Link
Speed.
SMART Reporting
Determines whether hard-drive errors for internal drives are reported during
system startup. Off does not report errors. On reports errors.
(Off default)
30
Using the System Setup Program
Table 2-4. Onboard Devices Options
Option
Description
Integrated NIC
(On default)
Enables or disables the integrated Network Interface Controller (NIC). Off
disables the controller. On enables the controller. On w/PXE enables the
controller with PXE. On w/RPL enables the controller with RPL.
NOTE: PXE or RPL is required only if you are booting to an operating system
on another system, not if you are booting to an operating system on a hard
drive in this system.
USB Controller
Enables or disables the internal USB controller. Off disables the
controller. On enables the controller. No Boot enables the controller, but
disables the ability to boot from a USB device.
(On default)
NOTE: Operating systems with USB support will recognize USB storage
devices regardless of the No Boot setting.
Front USB Ports
Enables or disables the front USB ports independently of the rear ports. Off
disables the controller. On enables the controller. No Boot enables the
controller, but disables the ability to boot from a USB device.
(On default)
NOTE: Operating systems with USB support will recognize USB storage
devices regardless of the No Boot setting.
Serial Port #1
Serial Port 1 options are COM1, COM3, Auto, and Off.
(Auto default)
When serial port 1 is set to Auto, the integrated port automatically maps
to the next available port. Serial port 1 attempts to use COM1 first and
then COM3. If both addresses are in use for a specific port, the port is
disabled. When serial port is set to COM1, the integrated port is
configured at 3F8h with IRQ4. When the serial port is set to COM3, the
integrated port is configured at 3E8h with IRQ4.
If you set the serial port to Auto and add an expansion card with a port
configured to the same designation, the system automatically remaps the
integrated port to the next available port designation that shares the
same IRQ setting.
Table 2-5. Performance Options
Option
Description
Hyper-Threading
(On default)
Determines whether the physical processor appears as one or two logical
processors. The performance of some applications improve with
additional logical processors installed. On enables hyperthreading. Off
disables hyperthreading.
Multiple CPU Core
If the processor has multiple cores, specifies whether the processor will
have one or two cores enabled. The performance of some applications
will improve with the additional core. Off disables Multiple CPU Core
Technology. On enables Multiple CPU Core Technology.
(On default)
Using the System Setup Program
31
Table 2-5. Performance Options (continued)
Option
Description
Limit CPUID
Limits the maximum value the processor standard CPUID function will
support. Some operating systems will not complete installation when the
maximum CPUID is greater than 3.
Speed Step
If the processor supports Enhanced Speed Step Technology, specifies
whether the option is Off or On.
(Off default)
NOTICE: Before enabling the Speed Step option, ensure that the
operating system also supports Enhanced Speed Step Technology.
Enabling the feature on operating systems that do not support it may
cause unpredictable results. See the operating system’s
documentation for its supported features.
HDD Acoustic Mode
Allows you to optimize IDE-drive performance and noise level based on
personal preferences. Bypass is used for older drives. Quiet slows drive
performance but reduces drive noise. Suggested adjusts performance to
the manufacturers preferred mode. Performance increases drive
performance but may increase drive noise.
(Performance default)
Table 2-6. Security Options
Option
Description
Unlock Setup
If the admin password has not been set, this option is not visible. If the
admin password has been set, this option displays the current status of
your system password. Temporarily unlock setup by entering your admin
password.
Admin Password
Displays the current status of your System Setup program’s password
(Not Set default)
NOTE: See "Using the Admin Password" on page 37 for instructions on
assigning a setup password and using or changing an existing setup
password.
System Password
Displays the current status of your system's password security feature and
allows you to verify and assign a new system password.
(Not Set default)
NOTE: See "Using the System Password" on page 35 for instructions on
assigning a system password and using or changing an existing system
password.
Password Changes
Determines the interaction between the System password and the Admin
password. Locked prevents a user with a valid System password from
being able to modify the System password. Unlocked allows a user with a
valid System password to modify the System password.
(Unlocked default)
32
Using the System Setup Program
Table 2-6. Security Options (continued)
Option
Description
Chassis Intrusion
(On-Silent default)
Enables or disables the chassis-intrusion detection feature. When set to
On-Silent, chassis intrusion is detected but no warning message is
reported during start-up. When set to On, this field displays
DETECTED when the chassis cover has been opened. Pressing any edit
key acknowledges the intrusion and arms the system to look for further
security breaches. Off disables the chassis-intrusion detection feature.
Intrusion Alert
If an intrusion has been detected, press the <Enter> key to acknowledge
the intrusion and arm the system to look for further security breaches.
Execute Disable
Specifies whether or not Execute Disable Memory Protection Technology
is On or Off.
(On default)
Table 2-7. Power Management Options
Option
Description
AC Recovery
(Last default)
Determines how the system responds when AC power is re-applied after a
power loss. Off commands the system to stay off when the power is re-
applied. You must press the front-panel power button before the system
turns on. On commands the system to turn on when the power is re-
applied. Last commands the system to return to the last power state the
system was in just before it was turned off.
Auto Power On
Determines when to use the Auto Power Time setting to turn on the
system. Off commands the system to not use the Auto Power Time
feature. Everyday turns on the system every day at the time set in Auto
Power Time. Weekdays turns on the system every day from Monday
through Friday at the time set in Auto Power Time.
(Off default)
Auto Power Time
Low Power Mode
(Off default)
Determines the time that you want the system to turn on.
On conserves more power by removing power from most hardware
features. Off conserves less power and removes power from fewer
hardware features.
NOTE: With this option set to On, the integrated NIC will be disabled when
the system is in the Hibernate or Off states. Only add-in NICs will be able to
wake the system remotely.
Remote Wake Up
Determines how the system is turned on remotely from the Suspend,
Hibernate, or Off states. Off disables the NIC from waking up the
system. On enables the NIC to wake up the system. On w/ Boot to NIC
enables the NIC to wake up the system and boot from the network.
(Off default)
NOTE: If you want the system to perform a Remote Wake Up, you must first
set Low Power Mode to Off.
Using the System Setup Program
33
Table 2-8. Maintenance Options
Option
Description
Service Tag
Displays the system service tag. If the service tag is corrupted, the system
will prompt to enter the correct service tag upon entering the system
setup program.
SERR Message
Controls the SERR message mechanism. By default, this feature is On.
NOTE: Some graphics cards require that the SERR message mechanism be
disabled.
Load Defaults
Event Log
Allows you to restore all System Setup options to their factory defaults.
Allows you to view the Event Log. Entries are marked R for Read and U
for Unread. Mark All Entries Read puts an Rto the left of all the entries.
Clear Log clears the Event Log.
Table 2-9. POST Behavior Options
Option
Description
Fast Boot
(On default)
When enabled, this feature reduces system startup time by bypassing
some compatibility steps. Off does not skip any steps during system
startup. On starts the system more quickly.
Numlock Key
Determines the functionality of the numeric keys on the right side of
your keyboard. Off commands the right keypad keys to function as
arrows. On commands the right keypad keys to function as numbers.
(On default)
POST Hotkeys
Determines whether the sign-on screen displays a message stating the
keystroke sequence that is required to enter the Setup program or the
Quickboot feature. Setup & Boot Menu displays both messages
(F2=Setupand F11=Boot Menu). Setup displays the setup
message only (F2=Setup). Boot Menu displays the Quickboot
message only (F11=Boot Menu). None displays no message.
(Setup and Boot Menu
default)
Keyboard Errors
When set to Report (enabled) and an error is detected during POST, the
BIOS will display the error message and prompt you to press <F1> to
continue or press <F2> to enter System Setup.
(Report default)
When set to Do Not Report (disabled) and an error is detected during
POST, the BIOS will display the error message and continue booting the
system.
NOTE: When detected, some errors (such as CPU or PCI fan failure) will
display an error message and prompt you to press <F1> to continue, or
<F2> to enter the Setup Menu.
34
Using the System Setup Program
Password Features
NOTICE: The password features provide a basic level of security for the data on your system. If your data requires
more security, use additional forms of protection, such as data encryption programs.
NOTICE: Anyone can access the data stored on your system if you leave the system running and unattended
without having a system password assigned or if you leave your system unlocked so that someone can disable the
password by changing a jumper setting.
Your system is shipped to you without the system password feature enabled. If system security is a concern,
operate your system only with system password protection.
To change or delete an existing password, you must know the password (see "Deleting an Existing System
Password" on page 36). If you forget your password, you cannot operate your system or change settings in the
System Setup program until a trained service technician changes the password jumper setting to disable the
passwords, and erases the existing passwords. This procedure is described in "Disabling a Forgotten
Password" on page 104
.
Using the System Password
After a system password is assigned, only those who know the password have full use of the system. When
the System Password option is Set, the system prompts you for the system password after the system starts.
NOTE: If you have assigned an admin password (see "Using the Admin Password" on page 37), the system accepts
your admin password as an alternate system password.
Assigning a System Password
Before you assign a system password, enter the System Setup program and check the System Password
option.
When a system password is assigned, the setting shown for the System Password option is Set. If the setting
shown for the Password Changes is Unlocked, you can change the system password. If the Password
Changes option is Locked, you cannot change the system password. When the system password feature is
disabled by a jumper setting, the system password is Disabled, and you cannot change or enter a new system
password.
When a system password is not assigned and the password jumper on the system board is in the enabled
(default) position, the setting shown for the System Password option is Not Set and the Password Changes
field is Unlocked. To assign a system password:
1
2
3
Verify that the Password Changes option is set to Unlocked
Highlight the System Password option and press <Enter>.
Type your new system password.
.
You can use up to 32 characters in your password.
As you press each character key (or the spacebar for a blank space), a placeholder appears in the field.
Using the System Setup Program
35
The password assignment is not case-sensitive. However, certain key combinations are not valid. If you
enter one of these combinations, the system beeps. To erase a character when entering your password,
press <Backspace> or the left-arrow key.
NOTE: To escape from the field without assigning a system password, press <Esc> at any time prior to
completing step 5.
4
5
6
Press <Enter>.
To confirm your password, type it a second time and press <Enter>.
Press <Enter> again to continue.
The setting shown for the System Password changes to Set
.
7
Save and exit the System Setup program and begin using your system.
Using Your System Password to Secure Your System
NOTE: If you have assigned an admin password (see "Using the Admin Password" on page 37), the system accepts
your admin password as an alternate system password.
When the Password Status option is set to Unlocked, you have the option to leave the password security
enabled or to disable the password security.
To leave the password security enabled:
1
2
Turn on or reboot your system by pressing <Ctrl><Alt><Del>.
Type your password and press <Enter>.
When the Password Status option is set to Locked when you turn on or reboot your system, type your
password and press <Enter> at the prompt.
After you type the correct system password and press <Enter>, your system operates as usual.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your
password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the
system displays an error message showing the number of unsuccessful attempts and that the system has
halted. You are prompted to shut down your system. This message can alert you to an unauthorized person
attempting to use your system.
Even after you shut down and restart the system, the error message continues to be displayed until the
correct password is entered.
NOTE: You can use the Password Changes option in conjunction with the System Password and Admin Password
options to further protect your system from unauthorized changes.
Deleting an Existing System Password
1
2
3
Enter the System Setup program.
Highlight the System Password option, and press <Enter> to access the system password window.
Enter the old password, and press <Enter>.
36
Using the System Setup Program
4
5
Press <Enter> twice to enter a new blank password and to confirm the new blank password.
Press <Enter> again to continue.
The setting changes to Not Set
.
Changing an Existing System Password
1
2
3
4
5
6
Enter the System Setup program.
Highlight the System Password option, and press <Enter> to access the system password window.
Enter the old password, and press <Enter>.
Enter a new password, and press <Enter>.
Enter the new password again to confirm the change, and press <Enter>.
Press <Enter> to continue.
The setting remains Set
.
Using the Admin Password
Assigning an Admin Password
You can assign (or change) an admin password only when the Admin Password option selected is Not Set
.
To assign an admin password:
1
2
Highlight the Admin Password option and press <Enter>.
Type your new admin password.
You can use up to 32 characters in your password.
As you press each character key (or the spacebar for a blank space), a placeholder appears in the field.
The password assignment is not case-sensitive. However, certain key combinations are not valid. If you
enter one of these combinations, the system beeps. To erase a character when entering your password,
press <Backspace> or the left-arrow key.
NOTE: To escape from the field without assigning a system password, press <Enter> to move to another field,
or press <Esc> at any time prior to completing step 5.
3
4
Press <Enter>.
To confirm your password, type it a second time and press <Enter>.
The setting shown for the Admin Password changes to Set
.
5
Save and exit the System Setup program and begin using your system.
The next time you enter the System Setup program, the system prompts you for the admin password.
Using the System Setup Program
37
A change to the Admin Password option becomes effective immediately (restarting the system is not
required). By entering the System Password, you can scroll through and view all the screens, but you cannot
make changes to the settings for which a lock graphic is displayed in the upper right corner of the option
window.
Operating With an Admin Password Set
If Admin Password is Set, you must enter the correct admin password before you can modify most of the
System Setup options. When you start the System Setup program, the program prompts you to enter a
password.
If you do not enter the correct password in three attempts, the system lets you view, but not modify, the
System Setup screens—with the following exception: if System Password is not Set and is not locked
through the Password Changes option, you can assign a system password (however, you cannot disable or
change an existing system password).
NOTE: You can use the Password Changes option in conjunction with the Admin Password option to protect the
system password from unauthorized changes.
Deleting an Existing Admin Password
1
2
3
4
5
Enter the System Setup program.
Highlight the Admin Password option, and press <Enter> to access the admin password window.
Enter the old password, and press <Enter>.
Press <Enter> twice to enter a new blank password and to confirm the new blank password.
Press <Enter> again to continue.
The setting changes to Not Set
.
Changing an Existing Admin Password
1
2
3
4
5
6
Enter the System Setup program.
Highlight the Admin Password option, and press <Enter> to access the admin password window.
Enter the old password, and press <Enter>.
Enter a new password, and press <Enter>.
Press <Enter> to continue.
The setting remains Set
.
Disabling a Forgotten Password
See "Disabling a Forgotten Password" on page 104.
38
Using the System Setup Program
Installing System Components
This section describes how to install the following system components:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Front drive bezel
Diskette drive
Optical and tape drives
Hard drives
Expansion cards
SAS controller card
Memory
Microprocessor
Cooling fans
System battery
Power supply
Chassis intrusion switch
Bezel
I/O panel
System board
Recommended Tools
You may need the following items to perform the procedures in this section:
•
•
#2 Phillips screwdriver
Wrist grounding stra
p
Installing System Components
39
Inside the System
In Figure 3-1, the system cover is opened to provide an interior view of the system.
Figure 3-1. Inside the System
3
2
1
4
9
5
8
6
7
1
4
7
5.25-inch drive bays (2)
system board
2
5
8
drive cage
3
6
9
power supply
hard drives (2)
processor cooling fan
card cage fan
3.5-inch drive bay
heatsink and shroud assembly
The system board can accommodate one processor, five expansion cards, and four memory modules. The
hard drive bays provide space for up to two SAS or SATA hard drives. Drive bays in the front of the
system provide space for an optical drive, an optional tape drive or second optical drive, and an optional
diskette drive. A controller expansion card is required for SAS hard drives. Power is supplied to the
system board and internal peripherals through a single nonredundant power supply.
40
Installing System Components
Opening the System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
Press the power button to ground the system board.
If you have installed a padlock through the padlock ring on the back panel, remove the padlock.
Lay the system on its side as shown in Figure 3-2.
Open the system by sliding the cover release tab toward the rear of the system and lifting the cover off.
See Figure 3-2.
Closing the System
1
2
3
Ensure that all internal cables are connected and folded out of the way.
Ensure that no tools or extra parts are left inside the system.
Reinstall the system cover:
a
b
Insert the bottom edge of the cover into the bottom of the system chassis. See Figure 3-2.
Press down on the cover until the cover release tab snaps into place.
4
5
If applicable, install the padlock.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
After you open and close the cover, the chassis intrusion detector, if enabled, causes the following
message to appear on the screen at the next system start-up:
ALERT! Cover was previously removed.
6
To reset the chassis intrusion detector, press <F2> to enter the System Setup program. See "Using the
System Setup Program" on page 27.
NOTE: If a setup password has been assigned by someone else, contact your network administrator for
information on resetting the chassis intrusion detector.
Installing System Components
41
Figure 3-2. Opening and Closing the System
1
1
release tab
Front Drive Bezel
The front drive bezel is the cover for the optional diskette and 5.25-inch drives. To remove or install a
drive, you must first remove the front drive bezel.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Removing the Front Drive Bezel
1
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
NOTE: The sliding plate secures and releases the front drive bezel and helps to secure the drives.
42
Installing System Components
3
Slide the lever on the sliding plate in the direction of the arrow until it releases the front drive bezel
from its side hinges. See Figure 3-3.
4
5
Carefully tilt the front drive bezel away from the chassis and lift it out as shown in Figure 3-3.
Close the system. See "Closing the System" on page 41.
Replacing the Front Drive Bezel
1
2
Slide the lever on the sliding plate in the direction of the arrow and fit the bezel into the chassis.
Snap the bezel into place and release the lever.
Figure 3-3. Removing and Replacing the Front Drive Bezel
2
3
1
1
front drive bezel
2
sliding plate
3
arrow on the sliding plate
Removing an Insert on the Front Drive Bezel
If you install a drive in the 3.5-inch or 5.25-inch drive bays, first remove the corresponding insert on the
front drive bezel. From the back of the bezel, squeeze the tabs on the end of the insert and rotate the
insert away from the bezel. See Figure 3-4.
Installing System Components
43
Replacing an Insert on the Front Drive Bezel
If you remove a drive in the 3.5-inch or 5.25-inch drive bays, replace the corresponding insert on the front
drive bezel. From the back of the bezel, fit the tab on the end of the insert into the notch on the bezel and
snap the other end of the insert into place. See Figure 3-4.
Figure 3-4. Removing and Replacing the Front Drive Bezel Insert
1
2
4
3
1
4
front drive bezel
2
insert tabs
3
drive bezel insert
screws for an optional
5.25-inch drive (3)
Diskette Drive
The 3.5-inch drive bay supports an optional standard diskette drive.
Removing the Diskette Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
6
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Remove the front drive bezel. See "Removing the Front Drive Bezel" on page 42.
Disconnect the power and data cables from the diskette drive. See Figure 3-5.
Slide the lever on the sliding plate in the direction of the arrow. See Figure 3-5.
Hold the lever in position and slowly pull the drive out of the bay.
44
Installing System Components
Figure 3-5. Removing or Installing a Diskette Drive
4
3
5
2
1
6
1
4
arrow on the sliding plate
2
5
sliding plate
3
drive-stop tab
power cable to diskette
drive (P7)
data cable to diskette drive
6
data cable to system board
7
If you are permanently removing the drive, replace the 3.5-inch insert on front drive bezel. See
"Replacing an Insert on the Front Drive Bezel" on page 44.
If you are replacing the diskette drive, see "Installing a Diskette Drive" on page 45.
8
9
Replace the front drive bezel. See "Replacing the Front Drive Bezel" on page 43.
Close the system. See "Closing the System" on page 41.
10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Installing a Diskette Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Installing System Components
45
3
4
5
6
Unpack the replacement diskette drive, and prepare it for installation.
Check the documentation for the drive to verify that it is configured for your system.
Remove the 3.5-inch insert on the front drive bezel. See "Removing an Insert on the Front Drive Bezel"
on page 43.
7
8
Remove the four shoulder screws from the back of the insert. See Figure 3-4; the 3.5-inch insert holds
four screws.
Attach the four screws to the diskette drive as shown in Figure 3-6.
Figure 3-6. Installing Diskette Drive Shoulder Screws
1
1
screws (4)
9
Verify that the drive-stop tab on the drive cage is in the proper position. It should be in its lowermost
NOTE: Inserting a diskette drive into the drive bay with the drive-stop tab in the improper position will cause the
10 From the front of the chassis, slide the drive into the drive bay until the shoulder screws snap securely
into the sliding plate.
11 Connect the P7 power cable to the drive. See Figure 3-5.
12 Connect the data cable from the drive to the diskette drive connector (FLOPPY) on the system board.
13 Replace the front drive bezel. See "Replacing the Front Drive Bezel" on page 43.
14 Close the system. See "Closing the System" on page 41.
15 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
16 Enter the System Setup program and ensure that the drive’s controller is enabled. See "Using the
System Setup Program" on page 27.
46
Installing System Components
17 (Optional) Test the drive by running the system diagnostics. See "Running the System Diagnostics" on
page 97.
Optical and Tape Drives
In the upper 5.25-inch drive bay, you can install only an optical drive. In the lower 5.25-inch drive bay,
you can install either an optical or a tape backup unit.
Removing an Optical or Tape Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
6
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Remove the front drive bezel. See "Removing the Front Drive Bezel" on page 42.
Disconnect the power and data cables from the back of the drive. See Figure 3-7.
Slide the lever on the sliding plate in the direction of the arrow to release the shoulder screw.
Slide the drive out to remove it from the drive bay.
Installing System Components
47
Figure 3-7. Removing and Installing an Optical or Tape Drive
2
3
1
4
1
4
sliding plate
2
IDE data cable to drive
3
power cable to drive
IDE connector on system
board
7
8
If you are installing another drive in the bay, see "Installing an Optical or Tape Drive" on page 49.
If the drive is being permanently removed, install an insert on front drive bezel. See "Replacing an
Insert on the Front Drive Bezel" on page 44.
9
Replace the front drive bezel. See "Replacing the Front Drive Bezel" on page 43.
10 Close the system. See "Closing the System" on page 41.
11 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
48
Installing System Components
Installing an Optical or Tape Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
Unpack the drive and prepare it for installation. For instructions, see the documentation that
accompanied the drive.
If you are installing a SCSI tape drive, you must have a SCSI controller card installed (see "Installing
an Expansion Card" on page 57) and configure the tape drive according to the documentation that
came with the tape drive, based on the following guidelines:
a
Each device attached to a SCSI host adapter must have a unique SCSI ID number (narrow SCSI
devices use IDs 0 to 7; wide SCSI devices use IDs from 0 to 15). Set the drive’s SCSI ID to avoid
conflicts with other devices on the SCSI bus. For the default SCSI ID setting, see the
documentation provided with the drive.
NOTE: There is no requirement that SCSI ID numbers be assigned sequentially or that devices be attached to
the cable in order by ID number.
b
SCSI logic requires that the two devices at opposite ends of a SCSI chain be terminated and that
2
Turn off the system, including any attached peripherals, and disconnect the system from the electrical
outlet.
3
4
5
Remove the front drive bezel. See "Removing the Front Drive Bezel" on page 42.
If another drive is installed, remove it (see "Removing an Optical or Tape Drive" on page 47) and
remove the three shoulder screws to attach to the new drive (see Figure 3-8).
6
7
If the drive bay is empty, remove the insert on the front drive bezel. See "Removing an Insert on the
Front Drive Bezel" on page 43.
Remove the three shoulder screws from the insert, and attach them to the bottom row of holes on the
drive. See Figure 3-8.
Installing System Components
49
Figure 3-8. Installing Optical or Tape Drive Shoulder Screws
1
1
screws (3)
8
9
Gently slide the drive into place until you hear a click or feel the drive securely installed.
Attach the power cable to the drive. See Figure 3-7.
10 Attach the data cable:
•
If you are installing an IDE drive, another drive may be attached to the same data cable by another
•
SCSI controller card to the drive.
11 Check all cable connections, and fold cables out of the way to allow for airflow between the fan and
cooling vents.
14 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
15 If you installed an IDE drive, enter the System Setup program and ensure that the drive’s IDE
controller is enabled. See "Using the System Setup Program" on page 27.
16 (Optional) Test the drive by running the system diagnostics. See "Running the System Diagnostics" on
page 97.
50
Installing System Components
Hard Drives
Hard Drive Installation Guidelines
Your system contains up to two SATA or SAS hard drives in internal drive bays. Both drives must be
either SAS or SATA; mixed configurations are not supported. Up to two SATA drives may be connected
to the system’s integrated SATA controller or to an optional SAS controller expansion card. Up to two
SAS drives may be connected to an optional SAS controller expansion card. Table 3-1 describes the
possible drive configurations.
Table 3-1. Hard-Drive Configurations
Drive
Number
Drive Type
Location
Controller
Connector
1
SATA
HDD0
integrated SATA controller
SAS expansion card (slot 2)
SAS expansion card (slot 2)
integrated SATA
SATA0
HDD0
HDD0
SATA2
HDD1
HDD1
1
2
SAS
HDD0
HDD1
SATA
SAS expansion card (slot 2)
SAS expansion card (slot 2)
2
SAS
HDD1
Removing a Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Disconnect the hard drive power cable from the hard drive that you are removing.
Disconnect the blue data cable from the hard drive that you are removing by pulling up on the blue
tab.
5
Press the blue tabs on each side of the hard-drive bracket toward each other and slide the drive up and
out of the bay. See Figure 3-9.
Installing System Components
51
Figure 3-9. Removing and Installing a Hard Drive in the Drive Carrier
1
2
3
1
blue tabs (2)
drive bay
3
secondary hard drive bay
NOTE: If you do not intend to replace the drive, it is highly recommended that you remove the drive from the guide
bracket (see Figure 3-10) and insert the empty guide bracket back into the drive bay. This eliminates the likelihood
that the empty bracket will be misplaced or improperly stored while not in use.
6
7
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Installing a Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
Unpack the replacement hard drive and prepare it for installation.
Check the documentation for the hard drive to verify that the drive is configured for your system.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
If you are replacing a hard drive, remove the drive that you are replacing (see "Removing a Hard Drive"
on page 51).
If there is a hard-drive bracket in the empty hard-drive bay, remove the bracket by pressing the two tabs
toward each other and pulling it up and out of the drive bay.
52
Installing System Components
If a replacement hard drive does not have the hard-drive bracket attached, remove the bracket from the
old drive.
6
7
Snap the new drive into the guide bracket. See Figure 3-10.
Insert the guide bracket assembly into the drive bay until it snaps into place. See Figure 3-9.
Figure 3-10. Installing a Hard Drive in a Drive Bracket
1
2
1
hard drive
2
hard drive bracket
NOTICE: SAS drives and SATA drives cannot be mixed in the system. The drives must be either SATA or SAS hard
drives.
Connect the power cable to the hard drive.
8
9
Connect the data cable to the hard drive:
•
•
For connection to the integrated SATA controller (SATA hard drives only), connect the SATA data
cable to the SATA0 (first drive) and SATA2 (second drive) connectors on the system board. See
Figure 3-11. See Figure 6-2 for the location of the hard drive connectors on the system board.
For connection to a SAS controller expansion card (SAS or SATA hard drives), connect the data
cable from the SAS controller card and the power cable as shown in Figure 3-12. See "SAS
Controller Expansion Card" on page 58 for instructions about installing the card and routing
the cables.
Installing System Components
53
Figure 3-12. Cabling a SAS or SATA Hard Drive to a SAS Controller Expansion Card
1
2
3
4
5
7
6
1
SAS controller card
2
5
data cable to SAS controller
card
3
6
AUX_LED connector
4
7
power cable to hard drive
SAS or SATA hard drives (2)
data cable to hard drive
hard drive activity indicator
cable to SAS controller card
10 Ensure that all connectors are properly cabled and firmly seated.
12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
See the documentation that came with the drive for instructions on installing any software required for
drive operation.
13 Press <F2> to enter the System Setup program (see "Entering the System Setup Program" on
page 27), and ensure that the drive’s controller is enabled.
14 Exit the System Setup program and reboot the system.
Installing System Components
55
15 Partition and logically format the drive.
See the documentation for your operating system for instructions.
16 (Optional) Test the hard drive by running the system diagnostics. See "Running the System
Diagnostics" on page 97.
17 If the drive you just installed is the primary drive, install your operating system on the hard drive.
Expansion Cards
The system board can accommodate up to five expansion cards:
•
•
•
•
two 5-V, half-length 32-bit, 33-MHz PCI (slots 3 and 5)
one 2.5-Gb/sec PCIe x1 (slot 1)
one 2.5-Gb/sec PCIe x4 (slot 4)
one 2.5-Gb/sec PCIe x8 (slot 2)
See Figure 6-2 for the location of the expansion card slots.
NOTE: The size of the expansion card connectors for the PCI x4 card is PCIx 8, and for the PCI x8 card is PCI x16.
Removing an Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
6
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
To open the card retention door, press the two release tabs inward. See Figure 3-13.
If necessary, disconnect any cables from the card.
Grasp the card by its top corners and ease it out of its connector.
If you are removing the card permanently, install a filler bracket in the empty card slot.
NOTE: Filler brackets must be installed over empty expansion card slots to maintain Federal Communications
Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in
proper cooling and airflow inside the system.
56
Installing System Components
Figure 3-13. Removing and Installing an Expansion Card
1
2
3
4
5
1
4
release tabs (2)
alignment guide
2
5
card retention door
filler bracket
3
alignment bar
7
8
9
Close the card retention door to secure the remaining card(s) in the system. See Figure 3-13.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
10 Remove the card’s device driver from the operating system.
Installing an Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Installing System Components
57
3
4
To open the card retention door, press the two release tabs inward. See Figure 3-13.
If you are installing a new card, remove the filler bracket.
NOTE: Keep this bracket in case you need to remove the expansion card. Filler brackets must be installed
over empty expansion-card slots to maintain FCC certification of the system. The brackets also keep dust and
dirt out of the system and aid in proper cooling and airflow inside the system.
5
Prepare the card for installation.
See the documentation that came with the card for information on configuring the card, making
internal connections, or otherwise customizing it for your system.
NOTE: Some NICs automatically start the system when they are connected to a network.
6
7
Insert the card into the expansion card connector on the system board (SLOT1, SLOT2, SLOT3,
SLOT4, or SLOT5) and press down firmly. Ensure that the card is fully seated in the slot and all cards
and filler brackets are flush with the alignment bar. See Figure 6-2 for the location of the five
expansion card connectors.
Close the card retention door to secure the card(s) in the system.
NOTICE: Do not route card cables over or behind the cards. Cables routed over the cards can prevent the system
cover from closing properly or cause damage to the equipment.
8
9
Connect any cables that should be attached to the card.
See the documentation for the card for information about the card’s cable connections.
Close the system. See "Closing the System" on page 41.
10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
11 Install any device drivers required for the card as described in the documentation for the card.
SAS Controller Expansion Card
Read the installation instructions in the documentation for your SAS controller card. Install the card in
expansion card connector SLOT2 (see "Installing an Expansion Card" on page 57), and connect the
hard-drive activity indicator cable from the card to the AUX_LED connector on the system board (see
Figure 6-2 for the connector location). See "Hard Drives" on page 51 for information about connecting
hard drives.
Memory
The four memory module connectors on the system board can accommodate from 512 MB to 4 GB of
533-MHz and 667-MHz unbuffered ECC DDR II single or dual-rank memory modules. See Figure 6-2
for the location of the four memory module connectors.
NOTE: As shown in Figure 6-2, memory slots are not in numeric order on the system board. When installing
memory, take care to install it in the proper slots according to the configuration guidelines in Table 3-2. Installing
memory in the wrong slots will significantly reduce system performance.
58
Installing System Components
Memory Module Upgrade Kits
The system is upgradable to 4 GB by installing combinations of 512-MB and 1-GB 533-MHz or 667-MHz
unbuffered ECC DDR II single or dual-rank memory modules. You can purchase memory upgrade kits
from Dell.
Memory Module Installation Guidelines
•
•
•
If only one memory module is installed, it must be installed in connector DIMM_1.
If only one memory module is installed in connector DIMM_1, its capacity must be 512 MB.
If more than one memory module is installed, the memory modules must be installed in pairs of
matched memory size, speed, and technology.
•
•
Memory modules must be installed in ordered pairs in connectors DIMM_1 and DIMM_2, and then
DIMM_3 and DIMM_4.
If a processor with a slower front-side bus rating than the memory is installed, the memory will operate
at the processor’s slower front-side bus speed.
NOTICE: If you remove your original memory modules from the system during a memory upgrade, keep them
separate from any new memory modules that you may have, even if you purchased the new memory modules from
Dell. Use only unregistered or unbuffered ECC DDR II memory modules.
Table 3-2 illustrates memory configuration guidelines. It is important to follow the slot installation
configurations shown here to achieve maximum memory performance.
Table 3-2. Memory Configuration Guidelines
Total Memory
512 MB
1 GB
DIMM_1
512 MB
512 MB
512 MB
1 GB
DIMM_2
none
DIMM_3
none
DIMM_4
none
512 MB
512 MB
1 GB
none
none
2 GB
512 MB
none
512 MB
none
2 GB
3 GB
1 GB
1 GB
512 MB
1 GB
512 MB
1 GB
4 GB
1 GB
1 GB
Addressing Memory With 4-GB Configurations (Microsoft® Windows® Operating System Only)
Your system supports a maximum of 4 GB of memory using four 1-GB memory modules. Current
operating systems can use a maximum of 4 GB of address space; however, the amount of memory
available to the operating system is slightly less than 4 GB.
NOTE: Depending on the type of PCI/PCIe expansion cards that are installed in your system, your system may only
support a maximum of 3.4 GB of memory or less.
Installing System Components
59
The following components require address space:
•
•
•
•
System ROM
Advanced Programmable Interrupt Controllers (APIC)
Integrated PCI devices (such as NICs) and SCSI controllers
PCI expansion cards
At start-up, the BIOS identifies the components that require address space. The BIOS dynamically
calculates the amount of reserved address space required. The BIOS then subtracts the reserved address
space from 4 GB to determine the amount of usable space.
•
If the total installed system memory is less than the usable space, all installed system memory is
available for use only by the operating system.
•
If the total installed system memory is equal to or greater than the usable address space, a small
portion of installed memory is available for use by the operating system.
Removing a Memory Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Press out on the securing clip at each end of the memory module connector. See Figure 3-14.
Grasp the memory module and pull it out of the connector.
If the module is difficult to remove, gently move the module back and forth to remove it from the
connector.
Installing a Memory Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Press on the securing clip at each end of the memory module connector. See Figure 3-14.
Align the memory module’s edge connector with the alignment key in the connector.
The memory module connector has an alignment key that allows the memory module to be installed
in the connector in only one way.
60
Installing System Components
5
Applying even pressure to both ends of the module, insert the module into the connector and carefully
press the module into place.
Figure 3-14. Installing and Removing a Memory Module
1
4
3
2
1
4
memory module
2
alignment key
3
socket
memory module socket
ejectors (2)
6
Pull up on the securing clips to lock the module into place.
If you insert the module correctly, the securing clips snap into the cutouts at each end of the module.
When the memory module is properly seated in the connector, the securing clips on the memory
module socket should align with the securing clips on the other connectors with memory modules
installed.
7
8
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
The system detects that the new memory does not match the existing configuration information and
generates the following message:
The amount of system memory has changed.
Strike the F1 key to continue, F2 to run the setup utility
9
Press <F2> to enter the System Setup program and check the value for Memory Info. See "System
Setup Options" on page 28.
The system should have changed the value for Memory Info to reflect the newly installed memory.
Verify the new value. If it is correct, skip to step 13.
10 If the memory value is incorrect, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
Installing System Components
61
12 Ensure that the installed memory modules are seated properly in their connectors, and repeat step 7
through step 9.
13 When the Memory Info value is correct, press <Esc> to exit the System Setup program.
14 Run the system diagnostics to verify that the memory modules are operating properly. See "Running
the System Diagnostics" on page 98.
Microprocessor
You can upgrade the system processor to take advantage of future options in speed and functionality. The
processor and its associated internal cache memory are contained in a land grid array (LGA) package.
Removing the Processor
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: The processor and heat sink can get very hot during normal operation. Ensure that they have had
sufficient time to cool before you touch them.
1
2
3
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Using a #2 Phillips screwdriver, loosen the two captive screws holding the heat sink and shroud
assembly in place.
These captive screws are adjacent to the processor cooling fan housing. See Figure 3-15.
Tilt the heat sink and shroud assembly away from the fan housing and lift it out.
4
62
Installing System Components
5
Open the processor cover by sliding the release lever from under the release lever latch on the socket.
Then, pull the lever back to release the processor. See Figure 3-16.
Figure 3-16. Installing and Removing a Processor
1
7
2
6
3
4
5
1
4
7
processor
2
5
retention latch
tab
3
6
socket
release lever latch
release lever
notched processor edge
NOTICE: The retention latch is pressure-loaded. Ensure that the latch does not quickly open and strike the
processor or system board.
6
7
Carefully pivot the retention latch away from the processor.
NOTICE: Do not pry the processor from the socket by a single edge. This could result in damage to the processor’s
delicate connections.
NOTICE: Be careful not to touch or drop any foreign materials on the socket connector pads.
Lift the processor straight up and out of the socket.
Leave the release lever and retention latch in the release position so that the socket is ready for the new
processor.
64
Installing System Components
1
2
Unpack the new processor.
Ensure that the contacts on the bottom of the replacement processor are free from dirt or other foreign
material.
3
4
Align the notched edge of the replacement processor with the tab on the processor frame. See
Figure 3-16.
NOTICE: Use caution when removing and installing the processor. Damaging the processor socket connectors
can damage the system board.
Carefully set the processor in the processor frame. Ensure that the notched edge of the processor fits
securely over the matching tab on the processor frame. Do not press down on the processor. If the
processor is seated correctly, it should fit snugly in the socket frame. See Figure 3-16.
5
6
Lower the retention latch onto the processor, and then rotate the release lever back toward the system
board until it snaps into place.
Clean the thermal grease from the bottom of the heat sink.
NOTICE: Ensure that you apply new thermal grease. Applying new thermal grease is critical to ensuring proper
thermal bonding as well as optimal processor operation.
7
8
Place the heat sink assembly back onto the heat sink assembly bracket and tilt the heat sink assembly
down on the system board. See Figure 3-15.
9
Align the two captive screws properly with the system board, then tighten them to secure the heat sink
assembly to the system board.
10 Close the system. See "Closing the System" on page 41.
11 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Cooling Fans
The system contains two cooling fans, one for the processor and one for the card cage. Each contains a
shroud that is part of the cooling fan assembly. The fan and shroud are replaced as a unit.
NOTE: If you are removing the larger processor cooling fan, you must first remove the heat sink and shroud
assembly. See "Removing the Processor" on page 62 (however, do not remove the processor) and Figure 3-17.
Removing the Cooling Fans
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Installing System Components
65
3
4
Disconnect the fan’s power cable from the system board by depressing the locking tab. See Figure 3-17.
If you are removing the smaller card cage fan (see Figure 3-17):
a
b
Pull up on the single release tab that attaches the fan to the chassis.
Slide the fan toward the back panel and lift the fan out.
5
If you are removing the larger processor cooling fan (see Figure 3-17):
a
Remove the heat sink and shroud assembly. See "Removing the Processor" on page 62. Do not
remove the processor, however.
b
c
Press the release tab that attaches the processor cooling fan to the chassis.
Slide the fan toward the back panel and lift the fan out.
Figure 3-17. Removing and Installing the Cooling Fans
2
1
3
4
6
5
1
4
processor cooling fan
2
5
release tab for processor fan
release tab for card cage fan
3
connector for processor fan
(CPU_CAGE)
connector for card cage fan
(FAN_CARD_CAGE)
6
card cage fan
66
Installing System Components
Replacing the Cooling Fans
1
2
3
Align the securing tabs on the replacement fan with the mounting holes in the system chassis.
Slide the fan toward the front panel until it snaps into place.
If you replaced the larger processor cooling fan, replace the heat sink and shroud assembly (see
"Removing the Processor" on page 62).
4
5
Reconnect the fan power cable to the system board.
Close the system. See "Closing the System" on page 41.
System Battery
A coin-cell battery maintains system configuration, date, and time information. The battery can last
several years.
To determine whether you need to replace the battery, see "Troubleshooting the System Battery" on
page 85.
You can operate your system without a battery; however, without a battery, the configuration information
is erased if the system is turned off or unplugged from the electrical outlet. In this case, you must enter
the System Setup program and reset the configuration options.
CAUTION: A new battery can explode if it is incorrectly installed. Replace the battery only with the same or
equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s
instructions.
Removing the System Battery
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Enter the System Setup program and record the option settings on the System Setup screens. See
"Using the System Setup Program" on page 27
.
Turn off the system, including any attached peripherals, and disconnect the system from the electrical
outlet.
3
4
Open the system. See "Opening the System" on page 41.
See Figure 6-2 for the location of the system battery and then remove any cables that block access to
the battery.
NOTICE: If you use a blunt, nonconductive object to depress the tab next to the battery, be careful not to touch the
system board with the object. Ensure that the object is inserted between the battery and the tab before you attempt
to depress the tab. Do not pry out the battery. You may damage the system board by prying off the socket or by
breaking circuit traces on the system board.
Installing System Components
67
5
Press the tab on the battery socket to release the battery, then lift the battery out of the socket. See
Figure 3-18.
Figure 3-18. Removing and Installing the System Battery
2
3
1
1
battery socket
3
tab
Installing the System Battery
1
Install the new battery with the "+" facing up, and press down until it snaps into place. See
Figure 3-18
.
2
3
4
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet and turn on the system and attached peripherals.
Setup Program" on page 27
.
5
6
From the main screen, select System Time to enter the correct time and date.
Re-enter any system configuration information that is no longer displayed on the System Setup
screens, and then exit the System Setup program.
7
8
9
To test the newly installed battery, see "Troubleshooting the System Battery" on page 85.
After an hour, reconnect the system to a power source and turn it on.
Enter the System Setup program. If the time and date are still incorrect, see "Getting Help" on
page 107.
10 Properly dispose of the old battery. For more information, see your Product Information Guide.
68
Installing System Components
Power Supply
Removing the Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Depending on your system configuration, disconnect the following power cables:
•
•
•
•
P1 and P2 to the system board
P3 and P5 to the SATA or SAS drives
P7 to the diskette drive
P8, P9, and P10 to the optical and tape drives
NOTE: Note the routing of the DC power cables underneath the tabs in the system frame as you release the
tabs and remove the cables from the system board and drives. You must route these cables properly when
you replace them to prevent their being pinched or crimped.
4
Remove the heat sink and shroud assembly. Loosen the two captive screws holding the heat sink and
shroud assembly in place.
These captive screws are adjacent to the processor cooling fan housing. See Figure 3-15.
Tilt the heat sink and shroud assembly away from the fan housing and lift it out.
5
6
Remove the IDE, I/O panel, and SATA cables (if present) attached to the routing clamps on the side of
the power supply.
7
8
9
Using a #2 Phillips screwdriver, remove the four Phillips screws that secure the power supply to the
back panel.
Press the power-supply release tab down and slide the power supply toward the front of the system,
then lift it out of the system chassis. See Figure 3-19.
Remove the cable clamp and set it aside to attach to the new power supply.
Installing System Components
69
Figure 3-19. Removing the Power Supply
2
1
3
4
1
4
power supply release tab
cable clamp
2
power supply
3
screws (4)
Installing the Power Supply
1
2
3
Attach the cable clamp to the new power supply.
Align the power supply mounting holes with the mounting holes on the back panel.
Slide the power supply toward the back panel until it snaps into place over the power-supply release
tab.
4
5
Using a #2 Phillips screwdriver, install the four Phillips screws that secure the power supply to the back
panel.
Reattach the IDE, I/O panel, and SATA cables (if present) to the routing clamp on the side of the
power supply. Reroute the SATA power cables along the bottom of the chassis. These cables must lie
under the heat sink and shroud when the system is assembled.
6
Clean off the bottom of the heat sink and apply new thermal grease.
70
Installing System Components
7
8
9
Place the heat sink assembly onto the heat sink assembly bracket and tilt the heat sink assembly down
on the system board. See Figure 3-15.
Align the two captive screws with the system board and tighten them to secure the heat sink assembly
to the system board.
Depending on your system configuration, connect the following power cables:
•
•
•
•
P1 and P2 to the system board
P3 and P5 to the SATA or SAS drives
P7 to the diskette drive
P8, P9, and P10 to the optical and tape drives
10 Close the system. See "Closing the System" on page 41.
Chassis Intrusion Switch
Removing the Chassis Intrusion Switch
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Disconnect the chassis intrusion switch cable from the INTRUDER connector on the system board.
See Figure 3-20.
4
5
Slide the chassis intrusion switch out of the securing bracket notch. See Figure 3-20.
Remove the switch and its attached cable from the system.
Installing System Components
71
Figure 3-20. Removing and Installing the Chassis Intrusion Switch
1
2
3
1
chassis intrusion switch
2
securing bracket notch
3
INTRUDER connector
Installing the Chassis Intrusion Switch
1
2
3
4
5
Align the chassis intrusion switch with the securing bracket notch. See Figure 3-20.
Slide the switch into the securing bracket notch.
Connect the switch cable to the INTRUDER connector on the system board.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system.
72
Installing System Components
Bezel
Removing the Bezel
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
Open the system. See "Opening the System" on page 41.
Remove the heat sink and shroud assembly. See "Removing the Processor" on page 62. Do not remove
the processor, however.
4
5
6
Remove the large processor cooling fan. See "Removing the Cooling Fans" on page 65.
Remove the three bezel release screws. See Figure 3-21.
Slide the bezel toward the top of the system, then lift it outward.
Installing System Components
73
Figure 3-21. Removing the Bezel
1
2
1
bezel release screws (3)
2
Replacing the Bezel
1
2
3
4
5
6
Align the bezel with the chassis frame and slide it into position.
Attach the three bezel release screws to secure the bezel to the system chassis. See Figure 3-21.
Replace the processor fan. See "Replacing the Cooling Fans" on page 67.
Reinstall the heat sink and shroud assembly. See "Replacing the Processor" on page 65.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system.
I/O Panel Assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
74
Installing System Components
Removing the I/O Panel Assembly
1
2
3
Open the system. See "Opening the System" on page 41.
Remove the heat sink and shroud assembly. See "Removing the Processor" on page 62. Do not remove
the processor, however.
4
5
Remove the processor cooling fan. See "Removing the Cooling Fans" on page 65.
Remove the front bezel. See "Removing the Bezel" on page 73.
NOTICE: Carefully note the routing of each cable before you disconnect it, so that you are sure to re-route cables
correctly.
6
7
8
Disconnect the I/O panel ribbon cable from the I/O panel connector by pulling the yellow cable loop.
Remove the mounting screw holding the I/O panel assembly to the front chassis. See Figure 3-22.
Lift the I/O panel assembly out of the system.
Figure 3-22. Removing and Installing the I/O Panel Assembly
1
2
3
4
1
4
I/O panel assembly
2
I/O panel ribbon cable
3
holding tab on the chassis
screw on the I/O panel
Installing System Components
75
Replacing the I/O Panel Assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
Fit the I/O panel assembly into the holding tab on the front of the chassis. See Figure 3-22.
Secure the I/O panel assembly by replacing the screw. See Figure 3-22.
Replace the large processor cooling fan. See "Replacing the Cooling Fans" on page 67.
Replace the heat sink and shroud assembly. See "Replacing the Processor" on page 65.
NOTE: To prevent damaging the processor, clean the heat sink to remove any thermal grease and then apply fresh
thermal grease to the processor before installing the heat sink.
6
7
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system.
System Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: The heat sink can get hot during operation. To avoid burns, ensure that the system has sufficient time
to cool before removing the system board.
Removing the System Board
1
2
3
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Depending on your configuration, disconnect the following cables from the system board. See
Figure 6-2 for connector locations.
•
•
•
•
•
•
Two power-supply cables from the POWER and 12VPOWER connectors
Diskette data cable from the FLOPPY connector
I/O panel cable from the FRONTPANEL connector
5.25-inch device data cable from the IDE connector
Processor cooling fan cable from the FAN_CPU connector
Card cage cooling fan cable from the FAN_CARD_CAGE connector
76
Installing System Components
•
•
SATA hard-drive data cable(s) from the SATA connector(s)
Intrusion switch cable from the INTRUDER connector
4
5
Remove all expansion cards and any attached cables. See "Removing an Expansion Card" on page 56.
Remove all memory modules. See "Memory" on page 58.
NOTE: Record the memory-module socket locations to ensure proper reinstallation of the memory modules.
CAUTION: The processor and heat sink can become extremely hot. Allow sufficient time for the processor and
heat sink to cool before handling.
6
7
Remove the processor. See "Removing the Processor" on page 62.
Using a #2 Phillips screwdriver, remove the eight system board mounting screws that secure the system
board to the chassis. See Figure 3-23.
8
Using a #2 Phillips screwdriver, remove the two processor heat sink pivot mount screws and remove
the pivot mount from the system board. See Figure 3-23. The heat sink pivot mount screws are green
and are longer than the system board mounting screws.
Figure 3-23. System Board Mounting Points
1
2
3
1
heat sink pivot mount
screws (2)
2
system board mounting
screws (8)
3
system board
Installing System Components
77
9
Carefully route any loose cables away from the edges of the system board.
10 Gently slide the system board toward the front of the system, then lift the system board up and out of
the chassis.
Installing the System Board
1
2
3
After removing the old system board, lower the new system board into the chassis, aligning the I/O
ports on the system board with the I/O connector openings on the back panel of the chassis.
Using a #2 Phillips screwdriver, install the eight screws on the system board that secure it to the
chassis. See Figure 3-23.
Using a #2 Phillips screwdriver, attach the processor heat sink pivot mount to the system board. See
Figure 3-23.
NOTICE: To prevent damaging the processor, clean the heat sink to remove any thermal grease and then apply
fresh thermal grease to the processor before installing the heat sink.
4
5
Install the memory modules in the same sockets from which they were removed. See "Installing a
Memory Module" on page 60.
6
7
Install the expansion cards and connect any cables. See "Installing an Expansion Card" on page 57.
Depending on your configuration, connect the following cables that you removed in "Removing the
System Board" on page 76. See Figure 6-2.
•
•
•
•
•
•
•
•
Two power-supply cables to the POWER and 12VPOWER connectors
If applicable, diskette data cable to the FLOPPY connector
I/O panel cable to the FRONTPANEL connector
5.25-inch device data cable to the IDE connector
Processor cooling fan cable to the FAN_CPU connector
Card cage cooling fan cable to the FAN_CARD_CAGE connector
SATA hard-drive data cable(s) to the SATA connector(s)
Intrusion switch cable from the INTRUDER connector
8
9
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system.
78
Installing System Components
Troubleshooting Your System
Safety First—For You and Your System
To perform certain procedures in this document, you must remove the system cover and work inside
the system. While working inside the system, do not attempt to service the system except as
explained in this guide and elsewhere in your system documentation.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online
or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the product.
Start-Up Routine
Table 4-1. Start-Up Routine Indications
Look/listen for:
Action
An error message displayed on the monitor.
The monitor's power indicator.
page 81.
The keyboard indicators.
See "Troubleshooting the Keyboard" on page 81.
See "Troubleshooting a Diskette Drive" on page 89.
See "Troubleshooting an Optical Drive" on page 90.
See "Troubleshooting a Hard Drive" on page 91.
See "Getting Help" on page 107.
The diskette drive activity indicator.
The CD drive activity indicator.
The hard-drive activity indicator.
An unfamiliar constant scraping or grinding sound
Checking the Equipment
This section provides troubleshooting procedures for external devices attached to the system, such
as the monitor, keyboard, or mouse. Before you perform any of the procedures, see "Troubleshooting
External Connections" on page 80.
Troubleshooting Your System
79
Troubleshooting IRQ Assignment Conflicts
Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To
avoid this type of conflict, see the documentation for each PCI device for specific IRQ requirements.
Table 4-2 lists the IRQ assignments.
Table 4-2. IRQ Assignment Defaults
IRQ Line
IRQ0
Assignment
System timer
IRQ1
Keyboard controller
IRQ2
Interrupt controller 1 to enable IRQ8 through IRQ15
Serial port 2 (COM2 and COM4)
Serial port 1 (COM1 and COM3)
Remote access controller
Diskette drive (optional) controller
Real-time clock
IRQ3
IRQ4
IRQ5
IRQ6
IRQ8
IRQ9
ACPI functions (used for power management)
Available
IRQ10
IRQ11
IRQ13
IRQ14
IRQ15
Available
Math coprocessor
IDE CD drive controller
Available
Troubleshooting External Connections
Loose or improperly connected cables are the most likely source of problems for the system, monitor, and
other peripherals (such as a printer, keyboard, mouse, or other external device). Ensure that all external
cables are securely attached to the external connectors on your system. See Figure 1-2 for the back-panel
connectors on your system.
80
Troubleshooting Your System
Troubleshooting the Video Subsystem
Problem
•
Monitor is not working properly.
Action
1
2
Check the system and power connections to the monitor.
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
If the tests run successfully, the problem is not related to video hardware.
If the problem is not resolved, see "Getting Help" on page 107.
Troubleshooting the Keyboard
Problem
•
•
System message indicates a problem with the keyboard.
Keyboard is not functioning properly.
Action
1
Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System
Setup Program" on page 27.
2
3
Examine the keyboard and its cable for signs of damage.
Swap the faulty keyboard with a working keyboard.
If the problem is resolved, replace the faulty keyboard. See "Getting Help" on page 107
.
4
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
If the problem is not resolved, see "Getting Help" on page 107.
Troubleshooting the Mouse
Problem
•
•
System message indicates a problem with the mouse.
Mouse is not functioning properly.
Action
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
1
If the test fails, continue to the next step.
Troubleshooting Your System
81
2
Examine the mouse and its cable for signs of damage.
If the mouse is not damaged, go to step 4.
If the mouse is damaged, continue to the next step.
3
4
Swap the faulty mouse with a working mouse.
If the problem is resolved, replace the faulty mouse. See "Getting Help" on page 107
.
Enter the System Setup program and ensure that the USB port is enabled. See "Using the System
Setup Program" on page 27.
If the problem is not resolved, see "Getting Help" on page 107
.
Troubleshooting Basic I/O Problems
Troubleshooting a Serial Port
Problem
•
•
Error message indicates a problem with a serial port.
Device connected to a serial port is not operating properly.
Action
1
2
3
Enter the System Setup program and ensure that the serial port is enabled and configured correctly for
your application. See "Using the System Setup Program" on page 27.
If the problem is confined to a particular application, see the application documentation for specific
port configuration requirements that the program may require.
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
If the tests run successfully but the problem persists, see "Getting Help" on page 107.
Troubleshooting a USB Device
Problem
•
•
System message indicates a problem with a USB device.
Device connected to a USB port is not operating properly.
Action
1
Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System
Setup Program" on page 27.
2
3
Turn off the system and any USB devices.
Disconnect the USB devices, and connect the malfunctioning device to the other USB connector.
82
Troubleshooting Your System
4
5
Turn on the system and the reconnected device.
If the problem is resolved, the USB connector might be defective. See "Getting Help" on page 107
.
If possible, swap the interface cable with a working cable.
If the problem is resolved, replace the interface cable. See "Getting Help" on page 107
.
6
7
Turn off the system and the USB device, and swap the device with a comparable device.
Turn on the system and the USB device.
If the problem is resolved, replace the USB device. See "Getting Help" on page 107
.
If the problem persists, see "Getting Help" on page 107
.
Troubleshooting a NIC
Problem
•
NIC cannot communicate with network.
Action
1
2
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Check the appropriate indicator on the NIC connector.
•
•
If the link indicator does not light, check all cable connections.
If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's documentation.
•
•
Change the autonegotiation setting, if possible.
If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.
3
4
5
6
Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's
documentation.
Program" on page 27.
Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission
speed. See the network equipment documentation.
Ensure that all network cables are of the proper type and do not exceed the maximum length.
If the problem persists, see "Getting Help" on page 107
.
Troubleshooting Your System
83
Troubleshooting a Wet System
Problem
•
•
Liquid spilled on the system.
Excessive humidity.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
5
6
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Remove all expansion cards installed in the system. See "Removing an Expansion Card" on page 56.
Let the system dry thoroughly for at least 24 hours.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the system does not start properly, see "Getting Help" on page 107
.
7
8
If the system starts properly, shut down the system and reinstall all of the expansion cards that you
removed. See "Installing an Expansion Card" on page 57.
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
If the tests fail, see "Getting Help" on page 107
.
Troubleshooting a Damaged System
Problem
•
System was dropped or damaged.
84
Troubleshooting Your System
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Open the system. See "Opening the System" on page 41.
Ensure that the following components are properly installed:
•
•
•
•
•
•
Expansion cards
Power supply
Fans
Processors and heat sinks
Memory modules
3
4
5
Ensure that all cables are properly connected.
Close the system. See "Closing the System" on page 41.
Run the system board tests in the system diagnostics. See "Running the System Diagnostics" on
page 97.
If the tests fail, see "Getting Help" on page 107
.
Troubleshooting the System Battery
Problem
•
•
•
System message indicates a problem with the battery.
System Setup program loses system configuration information.
System date and time do not remain current.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system
configuration information. This situation is caused by a defective battery.
Action
1
Re-enter the time and date through the System Setup program. See "Using the System Setup Program"
2
3
4
Turn off the system and disconnect it from the electrical outlet for at least one hour.
Reconnect the system to the electrical outlet and turn on the system.
Enter the System Setup program. See "Using the System Setup Program" on page 27.
If the date and time are not correct in the System Setup program, replace the battery. See "System
Battery" on page 67.
Troubleshooting Your System
85
If the problem is not resolved by replacing the battery, see "Getting Help" on page 107
.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate
normally except for the time kept in the System Setup program, the problem may be caused by software rather than
by a defective battery.
Troubleshooting Power Supply
Problem
•
Power-supply fault indicator is blinking amber.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Check that the voltage selection switch on the back panel of the system is set properly. See "Power
Supply Indicators" on page 15.
NOTICE: Setting the voltage selection switch to an improper setting can damage your system.
4
Ensure that the power supply is properly installed by removing and reinstalling it. See "Installing the
Power Supply" on page 70.
NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply
and to determine if it is working properly. The power indicator turns green to signify that the power supply is
functioning properly.
5
6
If the problem is resolved, close the system. See "Closing the System" on page 41.
If the problem persists, remove the faulty power supply. See "Removing the Power Supply" on page 69.
Install a new power supply. See "Installing the Power Supply" on page 70.
If the problem persists, see "Getting Help" on page 107.
Troubleshooting System Cooling Problems
Problem
•
Systems management software issues a fan-related error message.
Action
Ensure that none of the following conditions exist:
86
Troubleshooting Your System
•
•
•
•
•
System cover, drive blank, or front or back filler panel is removed.
Ambient temperature is too high.
External airflow is obstructed.
Cables inside the system obstruct airflow.
An individual cooling fan is removed or has failed. See "Troubleshooting a Fan" on page 87.
Troubleshooting a Fan
Problem
•
•
System-status indicator is amber.
System message indicates a fan-related error message.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "Cooling
Fans" on page 65.
5
6
7
Close the system. See "Closing the System" on page 41.
Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, install a new fan. See "Cooling Fans" on page 65.
If the replacement fan is working properly, close the system. See "Closing the System" on page 41.
If the replacement fan does not operate, see "Getting Help" on page 107
.
Troubleshooting System Memory
Problem
•
•
•
Faulty memory module.
Faulty system board.
Diagnostic indicator code indicates a problem with system memory.
Troubleshooting Your System
87
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Turn off the system and attached peripherals, and then turn them on again.
If an error message does not appear, continue to the next step.
If an error message appears, go to step 11.
3
Enter the System Setup program and check the system memory setting. See "Using the System Setup
Program" on page 27.
If the amount of memory installed matches the system memory setting, go to step 11.
4
5
6
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Ensure that the memory banks are populated correctly. See "Memory Module Installation Guidelines"
on page 59.
If the memory modules are populated correctly, continue to the next step.
7
8
9
Reseat the memory modules in their sockets. See "Installing a Memory Module" on page 60.
Close the system. See "Closing the System" on page 41.
setting, proceed to the next step.
11 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
12 Open the system. See "Opening the System" on page 41.
NOTE: Several configurations for the memory modules exist; see "Memory Module Installation Guidelines" on
page 59.
13 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the
module. Otherwise, swap the memory module in socket 1 with a module of the same type and capacity
that is known to be good. See "Installing a Memory Module" on page 60.
14 Close the system. See "Closing the System" on page 41.
15 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
16 As the system boots, observe any error message that appears and the diagnostic indicators on the front
of the system.
88
Troubleshooting Your System
17 If the memory problem is still indicated, repeat step 11 through step 16 for each memory module
installed.
If the problem persists, see "Getting Help" on page 107.
Troubleshooting a Diskette Drive
Problem
•
Error message indicates a diskette drive problem.
Action
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
Enter the System Setup program and verify that the diskette drive is configured correctly. See "Using
the System Setup Program" on page 27.
2
3
4
5
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Open the system. See "Opening the System" on page 41.
Ensure that the diskette drive interface cable is securely connected to the diskette drive and the system
board.
6
7
8
9
Ensure that a power cable is properly connected to the drive.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Run the appropriate online diagnostic test to see whether the diskette drive works correctly.
If the problem persists, continue with the following steps.
10 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
11 Open the system. See "Opening the System" on page 41.
12 Remove all expansion cards installed in the system. See "Removing an Expansion Card" on page 56.
13 Close the system. See "Closing the System" on page 41.
14 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
15 Run the appropriate online diagnostic test to see whether the diskette drive works correctly.
If the tests run successfully, an expansion card may be conflicting with the diskette drive logic, or an
expansion card may be faulty. Continue to the next step.
If the tests fail, see "Getting Help" on page 107
.
Troubleshooting Your System
89
16 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
17 Open the system. See "Opening the System" on page 41.
18 Reinstall one of the expansion cards you removed in step 12. See "Installing an Expansion Card" on
page 57.
20 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
21 Run the appropriate online diagnostic test to see whether the diskette drive works correctly.
22 Repeat step 16 through step 21 until all expansion cards are reinstalled or one of the expansion cards
causes the tests to fail.
If the problem is not resolved, see "Getting Help" on page 107
.
Troubleshooting an Optical Drive
Problem
•
•
System cannot read data from a CD or DVD in an optical drive.
Optical drive indicator does not blink during boot.
Action
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Enter the System Setup program and ensure that the drive’s IDE controller is enabled. See "Using the
System Setup Program" on page 27.
3
4
5
6
7
8
9
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Ensure that the interface cable is securely connected to the optical drive and to the controller.
Ensure that a power cable is properly connected to the drive.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, see "Getting Help" on page 107
.
90
Troubleshooting Your System
Troubleshooting an IDE Tape Drive
Problem
•
•
•
System cannot read data from a tape in an IDE tape drive.
Diagnostic indicators or system messages indicate a tape drive-related failure.
Tape drive indicator (if applicable) does not blink during boot.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Try using a different tape that you know works properly.
If the problem persists, continue with the following steps.
Enter the System Setup program and ensure that the drive’s IDE controller is enabled. See "Using the
System Setup Program" on page 27.
3
4
5
6
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Open the system. See "Opening the System" on page 41.
Ensure that the IDE interface cable is securely connected to the tape drive and to the IDE connector
on the system board.
7
8
9
Ensure that a power cable is properly connected to the drive.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, see "Getting Help" on page 107.
Troubleshooting a Hard Drive
Problem
•
•
Device driver error.
One or more hard drives not recognized by the system.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Troubleshooting Your System
91
NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up
all files on the hard drive.
1
Run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on page 97.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
2
3
If you are experiencing problems with multiple hard drives, skip to step 5. For a problem with a single
hard drive, continue to the next step.
If your system has a SAS RAID controller, perform the following steps.
a
Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.
See the documentation supplied with the host adapter for information about the configuration
utility.
b
c
Ensure that the hard drive has been configured correctly for the RAID.
Exit the configuration utility and allow the system to boot to the operating system.
4
5
installed and are configured correctly. See the operating system documentation for more information.
Check the cable connections inside the system:
a
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
b
c
Verify that the cable connections between the hard drive(s) and the drive controller are correct,
or a SAS RAID controller. See "Hard Drives" on page 51.
d
e
f
Verify that the SAS or SATA cables are securely seated in their connectors.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, see "Getting Help" on page 107
.
Troubleshooting a SAS RAID Controller
NOTE: When troubleshooting a SAS RAID controller, also see the documentation for your operating system and
the controller.
Problem
•
•
Error message indicates a problem with the SAS RAID controller.
SAS RAID controller performs incorrectly or not at all.
92
Troubleshooting Your System
Action
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.
Enter the System Setup program and ensure that the SAS RAID controller is enabled. See "Using the
System Setup Program" on page 27.
3
4
Restart the system and press <Ctrl><C> for the installed controller card to enter the configuration
utility program.
See the controller's documentation for information about configuration settings.
Check the configuration settings, make any necessary corrections, and restart the system.
If the problem is not resolved, continue to the next step.
5
6
7
Open the system. See "Opening the System" on page 41.
Ensure that the controller card is firmly seated into the system board connector. See "Installing an
Expansion Card" on page 57.
8
Verify that the cable connections between the hard drives and the SAS controller are correct. See "Hard
Drives" on page 51.
Ensure that the cables are firmly connected to the SAS controller and the hard drives.
Close the system. See "Closing the System" on page 41.
9
10 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. If the
problem persists, see "Getting Help" on page 107
.
Troubleshooting Expansion Cards
NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the
expansion card.
Problem
•
•
Error message indicates a problem with an expansion card.
Expansion card performs incorrectly or not at all.
Troubleshooting Your System
93
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
Run the appropriate online diagnostic test for the expansion card which is exhibiting issues. See "Using
Dell PowerEdge Diagnostics" on page 97. Follow any recommended actions provided by the
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion Card"
on page 57.
5
6
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, go to the next step.
7
8
9
Open the system. See "Opening the System" on page 41.
Remove all expansion cards in the system. See "Removing an Expansion Card" on page 56.
NOTE: If your operating system is running off a disk controller card (such as a SAS controller card), do not
remove it.
11 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
12 Run the appropriate online diagnostic test for any item in the system that doesn’t require an expansion
card.
13 If the problem persists, run the appropriate online diagnostic test on each card. See "Using Dell
PowerEdge Diagnostics" on page 97.
a
b
c
d
e
f
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Remove an expansion card. See "Removing an Expansion Card" on page 56.
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Run the appropriate online diagnostic test.
If the tests fail, repeat step 13 for each expansion card until you are able to single out the faulty
expansion card.
If the tests fail for all expansion cards, see "Getting Help" on page 107
.
94
Troubleshooting Your System
Troubleshooting the Microprocessor
Problem
•
•
•
Error message indicates a processor problem.
Diagnostic indicator code indicates a problem with the processor or system board.
A heat sink is not installed for the processor.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
If possible, run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on
page 97.
2
3
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
Ensure that the processor and heat sink are properly installed. See "Replacing the Processor" on
page 65.
5
6
7
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If possible, run the appropriate online diagnostic test. See "Running the System Diagnostics" on
page 97.
If the tests fail or the problem persists, continue to the next step.
8
9
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
10
Replace the processor. See "Replacing the Processor" on page 65.
11 Close the system. See "Closing the System" on page 41.
12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13 Run the appropriate online diagnostic test. See "Running the System Diagnostics" on page 97.
If the problem persists, the system board is faulty. See "Getting Help" on page 107.
Troubleshooting Your System
95
96
Troubleshooting Your System
Running the System Diagnostics
If you experience a problem with your system, run the diagnostics before calling for technical assistance.
The purpose of the diagnostics is to test your system's hardware without requiring additional equipment
or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use
diagnostics test results to help you solve the problem.
Using Dell PowerEdge Diagnostics
®
®
To assess a system problem, first use the online Dell PowerEdge Diagnostics. Dell PowerEdge
Diagnostics is a suite of diagnostic programs, or test modules, that include diagnostic tests on chassis
and storage components such as hard drives, physical memory, communications and printer ports,
NICs, CMOS, and more. If you are unable to identify the problem using the PowerEdge Diagnostics,
then use the system diagnostics.
®
®
The files required to run PowerEdge Diagnostics for systems running supported Microsoft Windows
and Linux operating systems are available at support.dell.com and on the CDs that came with your
system. For information about using diagnostics, see the Dell PowerEdge Diagnostics User's Guide.
System Diagnostics Features
The system diagnostics provides a series of menus and options for particular device groups or devices.
The system diagnostics menus and options allow you to:
•
•
•
•
•
Run tests individually or collectively.
Control the sequence of tests.
Repeat tests.
Display, print, or save test results.
Temporarily suspend testing if an error is detected or terminate testing when a user-defined error
limit is reached.
•
•
•
View help messages that briefly describe each test and its parameters.
View status messages that inform you if tests are completed successfully.
View error messages that inform you of problems encountered during testing.
Running the System Diagnostics
97
When to Use the System Diagnostics
If a major component or device in the system does not operate properly, component failure may be
indicated. As long as the microprocessor and the system's input/output devices (monitor, keyboard, and
diskette drive) are functioning, you can use the system diagnostics to help identify the problem.
Running the System Diagnostics
The system diagnostics is run from the utility partition on your hard drive.
NOTICE: Use the system diagnostics to test only your system. Using this program with other systems may cause
invalid results or error messages. In addition, use only the program that came with your system (or an updated
version of that program).
1
2
As the system boots, press <F10> during POST.
From the utility partition main menu, select Run System Diagnostics, or select Run Memory
Diagnostics if you are troubleshooting memory.
When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing.
Next, the Diagnostics menu appears. The menu allows you to run all or specific diagnostics tests or to exit
the system diagnostics.
NOTE: Before you read the rest of this section, start the system diagnostics so that you can see the utility on your
screen.
System Diagnostics Testing Options
Click the testing option in the Main Menu window. Table 5-1 provides a brief explanation of testing
options.
Table 5-1. System Diagnostics Testing Options
Testing Option
Function
Express Test
Performs a quick check of the system. This option runs device tests
that do not require user interaction. Use this option to quickly identify
the source of your problem.
Extended Test
Performs a more thorough check of the system. This test can take an
hour or longer.
Custom Test
Information
Tests a particular device.
Displays test results.
Using the Custom Test Options
When you select Custom Test in the Main Menu window, the Customize window appears and allows you
to select the device(s) to be tested, select specific options for testing, and view the test results.
98
Running the System Diagnostics
Selecting Devices for Testing
The left side of the Customize window lists devices that can be tested. Devices are grouped by device type
or by module, depending on the option you select. Click the (+) next to a device or module to view its
components. Click (+) on any component to view the tests that are available. Clicking a device, rather than
its components, selects all of the components of the device for testing.
Selecting Diagnostics Options
Use the Diagnostics Options area to select how you want to test a device. You can set the following options:
•
•
Non-Interactive Tests Only — When checked, runs only tests that require no user intervention.
Quick Tests Only — When checked, runs only the quick tests on the device. Extended tests will not
run when you select this option.
•
•
•
Show Ending Timestamp — When checked, time stamps the test log.
Test Iterations — Selects the number of times the test is run.
Log output file pathname — When checked, enables you to specify where the test log file is saved.
Viewing Information and Results
The tabs in the Customize window provide information about the test and the test results. The following
tabs are available:
•
•
•
•
•
Results — Displays the test that ran and the result.
Errors — Displays any errors that occurred during the test.
Help — Displays information about the currently selected device, component, or test.
Configuration — Displays basic configuration information about the currently selected device.
Parameters — If applicable, displays parameters that you can set for the test.
Running the System Diagnostics
99
100
Running the System Diagnostics
Jumpers and Connectors
This section provides specific information about the system jumpers and describes the connectors on
the various boards in the system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online
or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the product.
Figure 6-1 shows the location of the configuration jumpers on the system board. Table 6-1 lists the
jumper settings.
Jumpers and Connectors
101
Figure 6-1. System Board Jumpers
Table 6-1. System Board Jumper Settings
Jumper
Setting
Description
PSWD
(default) The password feature is enabled.
The password feature is disabled.
RTCRST
(default) The configuration settings in NVRAM are retained at system
boot.
The configuration settings in NVRAM are cleared at next
system boot.
102
Jumpers and Connectors
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
See Figure 6-2 and Table 6-2 for the location and description of the system board connectors.
Figure 6-2. System Board Connectors
1
2
3
4
5
6
7
20
19
8
9
10
18
17
11
12
13
16
15
14
Jumpers and Connectors
103
Table 6-2. System Board Connectors
Item
1
Connector
Description
12VPOWER
power
2
DIMM_1, DIMM_2, DIMM_3, memory modules
DIMM_4
3
BATTERY
FAN_MEM
FRONTPANEL
POWER
battery socket
memory fan
front panel
main power
IDE drive
4
5
6
7
IDE
8
SATA0, SATA1, SATA2, SATA3 SATA drives
9
RTCRST
RTC reset jumper
10
11
12
13
14
15
16
17
18
19
20
INTRUDER
SLOT1
chassis intrusion header
PCIe x1
SLOT2
PCIe x8
SLOT4
PCIe x4
SLOT3, SLOT5
AUX_LED
FLOPPY
PCI
auxiliary hard-drive LED
diskette drive
card cage fan
processor fan
password jumper
processor
FAN_CARD_CAGE
FAN_CPU
PSWD
CPU
Disabling a Forgotten Password
The password jumper on the system board enables the system password features or disables them and clears
any password(s) currently in use.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Open the system. See "Opening the System" on page 41.
104
Jumpers and Connectors
3
Move the PSWD jumper to the disabled position.
See Figure 6-1 to locate the password jumper on the system board.
4
5
Close the system. See "Closing the System" on page 41.
Reconnect the system to the electrical outlet, and turn on the system.
The existing passwords are not disabled (erased) until the system boots with the password jumper plug
removed. However, before you assign a new system and/or setup password, you must install the jumper
plug.
NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system
disables the new password(s) the next time it boots.
6
Turn off the system, including any attached peripherals, and disconnect the system from the electrical
outlet.
7
8
9
Move the PSWD jumper from the disabled position to the enabled position.
Close the system, reconnect the system to the electrical outlet, and turn on the system.
10 Assign a new system and/or setup password.
To assign a new password using the System Setup program, see "Using the System Password" on
page 35.
Jumpers and Connectors
105
106
Jumpers and Connectors
Getting Help
Obtaining Assistance
1
2
3
4
Run the system diagnostics and record any information provided.
Make a copy of the Diagnostics Checklist (see "Diagnostics Checklist" on page 111), and fill it out.
Use Dell's extensive suite of online services available at Dell Support at support.dell.com for help
with installation and troubleshooting procedures.
For more information, see "Online Services" on page 107.
5
If the preceding steps have not resolved the problem, call Dell for technical assistance.
NOTE: Call technical support from a phone near or at the system so that technical support can assist you with any
necessary procedures.
When prompted by Dell's automated telephone system, enter your Express Service Code to route
the call directly to the proper support personnel. If you do not have an Express Service Code, open
the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions.
For instructions on using the technical support service, see "Support Service" on page 108 and
"Before You Call" on page 110.
NOTE: Some of the following services are not always available in all locations outside the continental U.S. Call your
local Dell representative for information on availability.
Online Services
You can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL
SUPPORT page, and fill in the requested details to access help tools and information.
You can contact Dell electronically using the following addresses:
•
World Wide Web
www.dell.com/
www.dell.com/ap/ (Asian/Pacific countries only)
www.dell.com/jp (Japan only)
www.euro.dell.com (Europe only)
Getting Help
107
www.dell.com/la (Latin American countries)
www.dell.ca (Canada only)
•
Anonymous file transfer protocol (FTP)
ftp.dell.com/
Log in as user:anonymous, and use your e-mail address as your password.
•
Electronic Support Service
[email protected] (Asian/Pacific countries only)
support.jp.dell.com (Japan only)
support.euro.dell.com (Europe only)
•
Electronic Quote Service
[email protected] (Asian/Pacific countries only)
[email protected] (Canada only)
AutoTech Service
Dell's automated support service—AutoTech—provides recorded answers to the questions most
frequently asked by Dell customers about their portable and desktop computer systems.
When you call AutoTech, use your touch-tone telephone to select the subjects that correspond to your
questions.
The AutoTech service is available 24 hours a day, 7 days a week. You can also access this service through
the support service. See the contact information for your region.
Automated Order-Status Service
To check on the status of any Dell™ products that you have ordered, you can go to support.dell.com, or
you can call the automated order-status service. A recording prompts you for the information needed to
locate and report on your order. See the contact information for your region.
Support Service
Dell's support service is available 24 hours a day, 7 days a week, to answer your questions about Dell
hardware. Our support staff use computer-based diagnostics to provide fast, accurate answers.
To contact Dell's support service, see "Before You Call" on page 110 and then see the contact information
for your region.
108
Getting Help
Dell Enterprise Training and Certification
Dell Enterprise Training and Certification is available; see www.dell.com/training for more information.
This service may not be offered in all locations.
Problems With Your Order
If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact
Dell for customer assistance. Have your invoice or packing slip available when you call. See the contact
information for your region.
Product Information
If you need information about additional products available from Dell, or if you would like to place an
order, visit the Dell website at www.dell.com. For the telephone number to call to speak to a sales
specialist, see the contact information for your region.
Returning Items for Warranty Repair or Credit
Prepare all items being returned, whether for repair or credit, as follows:
1
the outside of the box.
For the telephone number to call, see the contact information for your region.
Include a copy of the invoice and a letter describing the reason for the return.
2
3
Include a copy of any diagnostic information, including the Diagnostics Checklist (see "Diagnostics
Checklist" on page 111), indicating the tests you have run and any error messages reported by the
system diagnostics.
4
5
Include any accessories that belong with the item(s) being returned (such as power cables, media such
as CDs and diskettes, and guides) if the return is for credit.
Pack the equipment to be returned in the original (or equivalent) packing materials.
You are responsible for paying shipping expenses. You are also responsible for insuring any product
returned, and you assume the risk of loss during shipment to Dell. Collect-on-delivery (C.O.D.)
packages are not accepted.
Returns that are missing any of the preceding requirements will be refused at our receiving dock and
returned to you.
Getting Help
109
Before You Call
NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone system
direct your call more efficiently.
Remember to fill out the Diagnostics Checklist (see "Diagnostics Checklist" on page 111). If possible,
turn on your system before you call Dell for technical assistance and call from a telephone at or near the
computer. You may be asked to type some commands at the keyboard, relay detailed information during
operations, or try other troubleshooting steps possible only at the computer system itself. Ensure that the
system documentation is available.
CAUTION: Before servicing any components inside your computer, see your Product Information Guide for
important safety information.
110
Getting Help
Diagnostics Checklist
Name:
Date:
Address:
Phone number:
Service Tag (bar code on the back of the computer):
Express Service Code:
Return Material Authorization Number (if provided by Dell support technician):
Operating system and version:
Peripherals:
Expansion cards:
Are you connected to a network? Yes No
Network, version, and network card:
Programs and versions:
See your operating system documentation to determine the contents of the system’s start-up
files. If possible, print each file. Otherwise, record the contents of each file before calling Dell.
Error message, beep code, or diagnostic code:
Description of problem and troubleshooting procedures you performed:
Getting Help
111
Contacting Dell
To contact Dell electronically, you can access the following websites:
•
www.dell.com
•
support.dell.com (support)
For specific web addresses for your country, find the appropriate country section in the table below.
NOTE: Toll-free numbers are for use within the country for which they are listed.
NOTE: In certain countries, support specific to Dell™ XPS™ computers is available at a separate telephone
number listed for participating countries. If you do not see a telephone number listed that is specific for XPS
computers, you may contact Dell through the support number listed and your call will be routed appropriately.
When you need to contact Dell, use the electronic addresses, telephone numbers, and codes provided in
the following table. If you need assistance in determining which codes to use, contact a local or an
international operator.
NOTE: The contact information provided was deemed correct at the time that this document went to print and is
subject to change.
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Anguilla
Website: www.dell.com.ai
E-mail: [email protected]
General Support
toll-free: 800-335-0031
Antigua and Barbuda
Website: www.dell.com.ag
E-mail: [email protected]
General Support
1-800-805-5924
Argentina (Buenos Aires)
International Access Code: 00
Country Code: 54
Website: www.dell.com.ar
E-mail: [email protected]
E-mail for desktop and portable computers:
City Code: 11
®
E-mail for servers and EMC storage products:
Customer Care
toll-free: 0-800-444-0730
toll-free: 0-800-444-0733
toll-free: 0-800-444-0724
0-810-444-3355
Technical Support
Technical Support Services
Sales
112
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Aruba
Website: www.dell.com.aw
E-mail: [email protected]
General Support
toll-free: 800-1578
Australia (Sydney)
Website: support.ap.dell.com
International Access Code: 0011 E-mail: support.ap.dell.com/contactus
Country Code: 61
City Code: 2
General Support
13DELL-133355
Austria (Vienna)
Website: support.euro.dell.com
Country Code: 43
Home/Small Business Sales
0820 240 530 00
0820 240 530 49
0820 240 530 14
0820 240 530 16
0820 240 530 81
0820 240 530 17
City Code: 1
Home/Small Business Fax
Home/Small Business Customer Care
Preferred Accounts/Corporate Customer Care
Support for XPS
Home/Small Business Support for all other Dell
computers
Preferred Accounts/Corporate Support
Switchboard
0820 240 530 17
0820 240 530 00
Bahamas
Website: www.dell.com.bs
E-mail: [email protected]
General Support
toll-free: 1-866-278-6818
Barbados
Website: www.dell.com/bb
E-mail: [email protected]
General Support
1-800-534-3142
Getting Help
113
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Belgium (Brussels)
International Access Code: 00
Country Code: 32
Website: support.euro.dell.com
Tech Support for XPS
Tech Support for all other Dell computers
Tech Support Fax
02 481 92 96
02 481 92 88
02 481 92 95
02 713 15 65
02 481 91 00
02 481 92 99
02 481 91 00
City Code: 2
Customer Care
Corporate Sales
Fax
Switchboard
Bermuda
Website: www.dell.com/bm
E-mail: [email protected]
General Support
1-877-890-0751
Bolivia
Website: www.dell.com/bo
E-mail: [email protected]
General Support
toll-free: 800-10-0238
Brazil
Website: www.dell.com/br
E-mail: [email protected]
Customer Support, Tech Support
Technical Support Fax
Customer Care Fax
International Access Code: 00
Country Code: 55
City Code: 51
0800 90 3355
51 3481 5470
51 3481 5480
Sales
0800 90 3390
British Virgin Islands
Brunei
General Support
toll-free: 1-866-278-6820
604 633 4966
Technical Support (Penang, Malaysia)
Customer Care (Penang, Malaysia)
Transaction Sales (Penang, Malaysia)
Country Code: 673
604 633 4888
604 633 4955
114
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Canada (North York, Ontario) Online Order Status: www.dell.ca/ostatus
International Access Code: 011 AutoTech (automated Hardware and Warranty
toll-free: 1-800-247-9362
Support)
Customer Service (Home Sales/Small Business)
toll-free: 1-800-847-4096
toll-free: 1-800-326-9463
Customer Service (med./large business,
government)
Customer Service (printers, projectors, televisions,
handhelds, digital jukebox, and wireless)
toll-free: 1-800-847-4096
toll-free: 1-800-906-3355
toll-free: 1-800-387-5757
1-877-335-5767
Hardware Warranty Support (Home Sales/Small
Business)
Hardware Warranty Support (med./large bus.,
government)
Hardware Warranty Support (printers, projectors,
televisions, handhelds, digital jukebox, and wireless)
Sales (Home Sales/Small Business)
Sales (med./large bus., government)
Spare Parts Sales & Extended Service Sales
toll-free: 1-800-387-5752
toll-free: 1-800-387-5755
1 866 440 3355
Cayman Islands
E-mail: [email protected]
General Support
1-877-262-5415
Chile (Santiago)
Country Code: 56
City Code: 2
Website: www.dell.com/cl
E-mail: [email protected]
Sales and Customer Support
toll-free: 1230-020-4823
Getting Help
115
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
China (Xiamen)
Country Code: 86
City Code: 592
Technical Support website: support.dell.com.cn
Customer Care E-mail: [email protected]
Technical Support Fax
592 818 1350
Technical Support (Dell™ Dimension™ and
Inspiron)
toll-free: 800 858 2968
Technical Support (OptiPlex™, Latitude™, and
Dell Precision™)
toll-free: 800 858 0950
Technical Support (servers and storage)
toll-free: 800 858 0960
toll-free: 800 858 2920
Technical Support (projectors, PDAs, switches,
routers, and so on)
Technical Support (printers)
Customer Care
toll-free: 800 858 2311
toll-free: 800 858 2060
592 818 1308
Customer Care Fax
Home and Small Business
Preferred Accounts Division
Large Corporate Accounts GCP
Large Corporate Accounts Key Accounts
Large Corporate Accounts North
toll-free: 800 858 2222
toll-free: 800 858 2557
toll-free: 800 858 2055
toll-free: 800 858 2628
toll-free: 800 858 2999
toll-free: 800 858 2955
Large Corporate Accounts North Government and
Education
Large Corporate Accounts East
toll-free: 800 858 2020
toll-free: 800 858 2669
Large Corporate Accounts East Government and
Education
Large Corporate Accounts Queue Team
Large Corporate Accounts South
Large Corporate Accounts West
Large Corporate Accounts Spare Parts
Website: www.dell.com/cl
toll-free: 800 858 2572
toll-free: 800 858 2355
toll-free: 800 858 2811
toll-free: 800 858 2621
Colombia
E-mail: [email protected]
General Support
01-800-915-4755
116
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Costa Rica
Website: www.dell.com/cr
E-mail: [email protected]
General Support
0800-012-0231
Czech Republic (Prague)
International Access Code: 00
Country Code: 420
Website: support.euro.dell.com
E-mail: [email protected]
Technical Support
22537 2727
22537 2707
22537 2714
22537 2728
22537 2711
Customer Care
Fax
Technical Fax
Switchboard
Denmark (Copenhagen)
International Access Code: 00
Country Code: 45
Website: support.euro.dell.com
Technical Support for XPS
Technical Support for all other Dell computers
Customer Care (Relational)
Home/Small Business Customer Care
Switchboard (Relational)
Switchboard Fax (Relational)
Switchboard (Home/Small Business)
Switchboard Fax (Home/Small Business)
Website: www.dell.com/dm
E-mail: [email protected]
General Support
7010 0074
7023 0182
7023 0184
3287 5505
3287 1200
3287 1201
3287 5000
3287 5001
Dominica
toll-free: 1-866-278-6821
Dominican Republic
Website: www.dell.com/do
E-mail: [email protected]
General Support
1-800-156-1588
Ecuador
Website: www.dell.com/ec
E-mail: [email protected]
General Support (calling from Quito)
General Support (calling from Guayaquil)
toll-free: 999-119-877-655-3355
toll-free: 1800-999-119-877-655-
3355
Getting Help
117
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
El Salvador
Website: www.dell.com/ec
E-mail: [email protected]
General Support
800-6132
Finland (Helsinki)
Website: support.euro.dell.com
Country Code: 358
Technical Support
0207 533 555
0207 533 538
0207 533 533
0207 533 540
0207 533 530
0207 533 533
0207 533 530
City Code: 9
Customer Care
Switchboard
Sales under 500 employees
Fax
Sales over 500 employees
Fax
France (Paris) (Montpellier)
International Access Code: 00
Country Code: 33
Website: support.euro.dell.com
Home and Small Business
Technical Support for XPS
0825 387 129
0825 387 270
0825 823 833
0825 004 700
04 99 75 40 00
0825 004 700
0825 004 701
04 99 75 40 01
City Codes: (1) (4)
Technical Support for all other Dell computers
Customer Care
Switchboard
Switchboard (calls from outside of France)
Sales
Fax
Fax (calls from outside of France)
Corporate
Technical Support
Customer Care
Switchboard
Sales
0825 004 719
0825 338 339
01 55 94 71 00
01 55 94 71 00
01 55 94 71 01
Fax
118
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Germany (Frankfurt)
International Access Code: 00
Country Code: 49
Website: support.euro.dell.com
E-mail: [email protected]
Technical Support for XPS
Technical Support for all other Dell computers
Home/Small Business Customer Care
Global Segment Customer Care
Preferred Accounts Customer Care
Large Accounts Customer Care
Public Accounts Customer Care
Switchboard
069 9792 7222
069 9792-7200
0180-5-224400
069 9792-7320
069 9792-7320
069 9792-7320
069 9792-7320
069 9792-7000
City Code: 69
Greece
Website: support.euro.dell.com
Technical Support
International Access Code: 00
Country Code: 30
00800-44 14 95 18
00800-44 14 00 83
2108129810
Gold Service Technical Support
Switchboard
Gold Service Switchboard
Sales
2108129811
2108129800
Fax
2108129812
Grenada
Guatemala
Guyana
E-mail: [email protected]
General Support
toll-free: 1-866-540-3355
1-800-999-0136
E-mail: [email protected]
General Support
E-mail: [email protected]
General Support
toll-free: 1-877-270-4609
Getting Help
119
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Hong Kong
Website: support.ap.dell.com
Country Code: 852
Technical Support (Dimension and Inspiron)
2969 3188
2969 3191
Technical Support (OptiPlex, Latitude, and Dell
Precision)
Technical Support (PowerApp™, PowerEdge™,
PowerConnect™, and PowerVault™)
2969 3196
Customer Care
3416 0910
3416 0907
3416 0908
3416 0912
2969 3105
Large Corporate Accounts
Global Customer Programs
Medium Business Division
Home and Small Business Division
India
E-mail: [email protected]
Technical Support
1600338045
and 1600448046
1600 33 8044
Sales (Large Corporate Accounts)
Sales (Home and Small Business)
1600 33 8046
120
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Ireland (Cherrywood)
International Access Code: 00
Country Code: 353
City Code: 1
Website: support.euro.dell.com
E-mail: [email protected]
Sales
Ireland Sales
01 204 4444
1850 200 778
1850 200 778
Dell Outlet
Online Ordering HelpDesk
Customer Care
Home User Customer Care
Small Business Customer Care
Corporate Customer Care
Technical Support
01 204 4014
01 204 4014
1850 200 982
Technical Support for XPS computers only
Technical Support for all other Dell computers
General
1850 200 722
1850 543 543
Fax/Sales Fax
01 204 0103
01 204 4444
Switchboard
U.K. Customer Care (dial within U.K. only)
Corporate Customer Care (dial within U.K. only)
U.K. Sales (dial within U.K. only)
Website: support.euro.dell.com
Home and Small Business
Technical Support
0870 906 0010
0870 907 4499
0870 907 4000
Italy (Milan)
International Access Code: 00
Country Code: 39
City Code: 02
02 577 826 90
02 696 821 14
02 696 821 13
02 696 821 12
Customer Care
Fax
Switchboard
Corporate
Technical Support
02 577 826 90
02 577 825 55
02 575 035 30
02 577 821
Customer Care
Fax
Switchboard
Getting Help
121
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Jamaica
E-mail: [email protected]
General Support (dial from within Jamaica only)
1-800-440-9205
Japan (Kawasaki)
Website: support.jp.dell.com
International Access Code: 001 Technical Support (servers)
toll-free: 0120-198-498
81-44-556-4162
Country Code: 81
Technical Support outside of Japan (servers)
City Code: 44
Technical Support (Dimension and Inspiron)
toll-free: 0120-198-226
81-44-520-1435
Technical Support outside of Japan (Dimension and
Inspiron)
Technical Support (Dell Precision, OptiPlex, and
Latitude)
toll-free:0120-198-433
81-44-556-3894
Technical Support outside of Japan (Dell Precision,
OptiPlex, and Latitude)
Technical Support (PDAs, projectors, printers,
routers)
toll-free: 0120-981-690
81-44-556-3468
Technical Support outside of Japan (PDAs,
projectors, printers, routers)
Faxbox Service
044-556-3490
044-556-3801
044-556-4240
044-556-1465
044-556-3433
24-Hour Automated Order Status Service
Customer Care
Business Sales Division (up to 400 employees)
Preferred Accounts Division Sales (over 400
employees)
Public Sales (government agencies, educational
institutions, and medical institutions)
044-556-5963
Global Segment Japan
Individual User
Switchboard
044-556-3469
044-556-1760
044-556-4300
122
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Korea (Seoul)
E-mail: [email protected]
International Access Code: 001 Support
toll-free: 080-200-3800
toll-free: 080-200-3801
Country Code: 82
Support (Dimension, PDA, Electronics and
Accessories)
City Code: 2
Sales
toll-free: 080-200-3600
2194-6202
Fax
Switchboard
2194-6000
Latin America
Customer Technical Support (Austin, Texas,
U.S.A.)
512 728-4093
Customer Service (Austin, Texas, U.S.A.)
512 728-3619
512 728-3883
Fax (Technical Support and Customer Service)
(Austin, Texas, U.S.A.)
Sales (Austin, Texas, U.S.A.)
512 728-4397
512 728-4600
SalesFax (Austin, Texas, U.S.A.)
or 512 728-3772
Luxembourg
Website: support.euro.dell.com
Support
International Access Code: 00
Country Code: 352
342 08 08 075
+32 (0)2 713 15 96
26 25 77 81
Home/Small Business Sales
Corporate Sales
Customer Care
+32 (0)2 481 91 19
26 25 77 82
Fax
Macao
Technical Support
toll-free: 0800 105
34 160 910
Country Code: 853
Customer Service (Xiamen, China)
Transaction Sales (Xiamen, China)
29 693 115
Getting Help
123
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Malaysia (Penang)
International Access Code: 00
Country Code: 60
Website: support.ap.dell.com
Technical Support (Dell Precision, OptiPlex, and
Latitude)
toll-free: 1 800 880 193
toll-free: 1 800 881 306
toll-free: 1800 881 386
Technical Support (Dimension, Inspiron, and
Electronics and Accessories)
City Code: 4
Technical Support (PowerApp, PowerEdge,
PowerConnect, and PowerVault)
Customer Care
toll-free: 1800 881 306
(option 6)
Transaction Sales
toll-free: 1 800 888 202
toll-free: 1 800 888 213
Corporate Sales
Mexico
E-mail: [email protected]
Customer Technical Support
International Access Code: 00
Country Code: 52
001-877-384-8979
or 001-877-269-3383
50-81-8800
Sales
or 01-800-888-3355
001-877-384-8979
or 001-877-269-3383
50-81-8800
Customer Service
Main
or 01-800-888-3355
Montserrat
E-mail: [email protected]
General Support
toll-free: 1-866-278-6822
001-800-882-1519
Netherlands Antilles
E-mail: [email protected]
General Support
124
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Netherlands (Amsterdam)
International Access Code: 00
Country Code: 31
Website: support.euro.dell.com
Technical Support for XPS
Technical Support for all other Dell computers
Technical Support Fax
020 674 45 94
020 674 45 00
020 674 47 66
020 674 42 00
020 674 4325
020 674 55 00
020 674 50 00
020 674 47 75
020 674 47 50
020 674 50 00
020 674 47 50
City Code: 20
Home/Small Business Customer Care
Relational Customer Care
Home/Small Business Sales
Relational Sales
Home/Small Business Sales Fax
Relational Sales Fax
Switchboard
Switchboard Fax
New Zealand
Website: support.ap.dell.com
E-mail: support.ap.dell.com/contactus
General Support
International Access Code: 00
Country Code: 64
Nicaragua
0800 441 567
E-mail: [email protected]
General Support
001-800-220-1377
Norway (Lysaker)
Website: support.euro.dell.com
Technical Support for XPS
Technical Support for all other Dell products
Relational Customer Care
Home/Small Business Customer Care
Switchboard
International Access Code: 00
Country Code: 47
815 35 043
671 16882
671 17575
23162298
671 16800
671 16865
Fax Switchboard
Panama
Peru
E-mail: [email protected]
General Support
011-800-507-1264
0800-50-669
E-mail: [email protected]
General Support
Getting Help
125
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Poland (Warsaw)
Website: support.euro.dell.com
Country Code: 48
Customer Service Phone
Customer Care
57 95 700
57 95 999
57 95 999
57 95 806
57 95 998
57 95 999
City Code: 22
Sales
Customer Service Fax
Reception Desk Fax
Switchboard
Portugal
Website: support.euro.dell.com
Technical Support
Customer Care
International Access Code: 00
Country Code: 351
707200149
800 300 413
Sales
800 300 410 or 800 300 411 or
800 300 412 or 21 422 07 10
Fax
21 424 01 12
Puerto Rico
E-mail: [email protected]
General Support
1-877-537-3355
St. Kitts and Nevis
Website: www.dell.com/kn
E-mail: [email protected]
General Support
toll-free: 1-866-540-3355
St. Lucia
Website: www.dell.com/lc
E-mail: [email protected]
General Support
1-800-882-1521
St. Vincent and the Grenadines Website: www.dell.com/vc
E-mail: [email protected]
General Support
toll-free: 1-877-441-4740
126
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Singapore (Singapore)
International Access Code: 005
Country Code: 65
NOTE: The phone numbers in this section should be
called from within Singapore or Malaysia only.
Website: support.ap.dell.com
Technical Support (Dimension, Inspiron, and
Electronics and Accessories)
toll-free: 1 800 394 7430
toll-free: 1 800 394 7488
toll-free: 1 800 394 7478
Technical Support (OptiPlex, Latitude, and Dell
Precision)
Technical Support (PowerApp, PowerEdge,
PowerConnect, and PowerVault)
Customer Care
toll-free: 1 800 394 7430
(option 6)
Transaction Sales
Corporate Sales
Website: support.euro.dell.com
E-mail: [email protected]
Technical Support
Customer Care
toll-free: 1 800 394 7412
toll-free: 1 800 394 7419
Slovakia (Prague)
International Access Code: 00
Country Code: 421
02 5441 5727
420 22537 2707
02 5441 8328
02 5441 8328
02 5441 7585
Fax
Tech Fax
Switchboard (Sales)
Website: support.euro.dell.com
E-mail: [email protected]
Gold Queue
South Africa (Johannesburg)
International Access Code:
09/091
011 709 7713
011 709 7710
011 709 7707
011 709 7700
011 706 0495
011 709 7700
604 633 4810
Country Code: 27
City Code: 11
Technical Support
Customer Care
Sales
Fax
Switchboard
Southeast Asian and Pacific
Countries
Technical Support, Customer Service, and Sales
(Penang, Malaysia)
Getting Help
127
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Spain (Madrid)
Website: support.euro.dell.com
International Access Code: 00
Country Code: 34
City Code: 91
Home and Small Business
Technical Support
902 100 130
902 118 540
902 118 541
902 118 541
902 118 539
Customer Care
Sales
Switchboard
Fax
Corporate
Technical Support
902 100 130
902 115 236
91 722 92 00
91 722 95 83
Customer Care
Switchboard
Fax
Sweden (Upplands Vasby)
International Access Code: 00
Country Code: 46
Website: support.euro.dell.com
Technical Support for XPS
Technical Support for all other Dell products
Relational Customer Care
Home/Small Business Customer Care
Employee Purchase Program (EPP) Support
Technical Support Fax
Sales
0771 340 340
08 590 05 199
08 590 05 642
08 587 70 527
020 140 14 44
08 590 05 594
08 590 05 185
City Code: 8
Switzerland (Geneva)
International Access Code: 00
Country Code: 41
Website: support.euro.dell.com
Technical Support for XPS
0848 33 88 57
0844 811 411
City Code: 22
Technical Support (Home and Small Business) for
all other Dell products
Technical Support (Corporate)
Customer Care (Home and Small Business)
Customer Care (Corporate)
Fax
0844 822 844
0848 802 202
0848 821 721
022 799 01 90
022 799 01 01
Switchboard
128
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
Taiwan
Website: support.ap.dell.com
Country Code: 886
Technical Support (OptiPlex, Latitude, Inspiron,
toll-free: 00801 86 1011
toll-free: 00801 60 1256
Dimension, and Electronics and Accessories)
Technical Support (PowerApp, PowerEdge,
PowerConnect, and PowerVault)
Customer Care
toll-free: 00801 60 1250
(option 5)
Transaction Sales
toll-free: 00801 65 1228
toll-free: 00801 651 227
Corporate Sales
Thailand
Website: support.ap.dell.com
International Access Code: 001 Technical Support (OptiPlex, Latitude, and Dell
toll-free: 1800 0060 07
toll-free: 1800 0600 09
Precision)
Country Code: 66
Technical Support (PowerApp, PowerEdge,
PowerConnect, and PowerVault)
Customer Care
toll-free: 1800 006 007
(option 7)
Corporate Sales
Transaction Sales
toll-free: 1800 006 009
toll-free: 1800 006 006
Trinidad/Tobago
Website: www.dell.com/tt
E-mail: [email protected]
General Support
1-800-805-8035
Turks and Caicos Islands
Website: www.dell.com/tc
E-mail: [email protected]
General Support
toll-free: 1-877-441-4735
Getting Help
129
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
U.K. (Bracknell)
Website: support.euro.dell.com
International Access Code: 00
Country Code: 44
E-mail: [email protected]
Customer Care website:
support.euro.dell.com/uk/en/ECare/form/home.asp
City Code: 1344
Sales
Home and Small Business Sales
Corporate/Public Sector Sales
Customer Care
0870 907 4000
01344 860 456
Home and Small Business Customer Care
Corporate Customer Care
0870 906 0010
01344 373 185
0870 906 0010
01344 373 186
01344 373 193
01344 373 199
01344 373 194
Preferred Accounts (500–5000 employees)
Global Accounts Customer Care
Central Government Customer Care
Local Government & Education Customer Care
Health Customer Care
Technical Support
Technical Support for XPS computers only
0870 366 4180
0870 908 0500
Technical Support (Corporate/Preferred
Accounts/PAD [1000+ employees])
Technical Support for all other products
General
0870 353 0800
0870 907 4006
Home and Small Business Fax
Website: www.dell.com/uy
E-mail: [email protected]
General Support
Uruguay
toll-free: 000-413-598-2521
130
Getting Help
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
U.S.A. (Austin, Texas)
Automated Order-Status Service
toll-free: 1-800-433-9014
toll-free: 1-800-247-9362
toll-free: 1-877-459-7298
International Access Code: 011 AutoTech (portable and desktop computers)
Country Code: 1
Hardware and Warranty Support (Dell TV,
Printers, and Projectors) for Relationship
customers
Americas Consumer XPS Support
toll-free: 1-800-232-8544
toll-free: 1-800-624-9896
Consumer (Home and Home Office) Support for
all other Dell products
Customer Service
toll-free: 1-800-624-9897
toll-free: 1-800-695-8133
Employee Purchase Program (EPP) Customers
Financial Services website:
www.dellfinancialservices.com
Financial Services (lease/loans)
Financial Services (Dell Preferred Accounts [DPA])
Business
toll-free: 1-877-577-3355
toll-free: 1-800-283-2210
Customer Service and Support
Employee Purchase Program (EPP) Customers
toll-free: 1-800-456-3355
toll-free: 1-800-695-8133
toll-free: 1-877-459-7298
Support for printers, projectors, PDAs, and MP3
players
Public (government, education, and healthcare)
Customer Service and Support
Employee Purchase Program (EPP) Customers
Dell Sales
toll-free: 1-800-456-3355
toll-free: 1-800-695-8133
toll-free: 1-800-289-3355
or toll-free: 1-800-879-3355
toll-free: 1-888-798-7561
toll-free: 1-800-671-3355
toll-free: 1-800-357-3355
toll-free: 1-800-247-4618
toll-free: 1-800-727-8320
toll-free: 1-877-DELLTTY
(1-877-335-5889)
Dell Outlet Store (Dell refurbished computers)
Software and Peripherals Sales
Spare Parts Sales
Extended Service and Warranty Sales
Fax
Dell Services for the Deaf, Hard-of-Hearing, or
Speech-Impaired
Getting Help
131
Country (City)
Department Name or Service Area,
Website and E-Mail Address
Area Codes,
Local Numbers, and
Toll-Free Numbers
International Access Code
Country Code
City Code
U.S. Virgin Islands
E-mail: [email protected]
General Support
1-877-702-4288
Venezuela
Website: www.dell.com/ve
E-mail: [email protected]
General Support
0800-100-4752
132
Getting Help
Glossary
This section defines or identifies technical terms,
abbreviations, and acronyms used in your system
documents.
BIOS — Basic input/output system. Your system’s BIOS
contains programs stored on a flash memory chip. The
BIOS controls the following:
• Communications between the processor and
peripheral devices
• Miscellaneous functions, such as system messages
A — Ampere(s).
bit — The smallest unit of information interpreted by
AC — Alternating current.
your system.
ACPI — Advanced Configuration and Power Interface. A
standard interface for enabling the operating system to
direct configuration and power management.
blade — A module that contains a processor, memory, and
a hard drive. The modules are mounted into a chassis that
includes power supplies and fans.
ambient temperature — The temperature of the area or
BMC — Baseboard management controller.
room where the system is located.
boot routine — A program that clears all memory,
initializes devices, and loads the operating system when
you start your system. Unless the operating system fails to
respond, you can reboot (also called warm boot) your
system by pressing <Ctrl><Alt><Del>. Otherwise, you
must restart the system by pressing the reset button or by
turning the system off and then back on.
ANSI — American National Standards Institute. The
primary organization for developing technology standards
in the U.S.
application — Software designed to help you perform a
specific task or series of tasks. Applications run from the
operating system.
ASCII — American Standard Code for Information
bootable diskette — A diskette that is used to start your
Interchange.
system if the system will not boot from the hard drive.
asset tag — An individual code assigned to a system,
usually by an administrator, for security or tracking
purposes.
BTU — British thermal unit.
bus — An information pathway between the components
of a system. Your system contains an expansion bus that
allows the processor to communicate with controllers for
the peripheral devices connected to the system. Your
system also contains an address bus and a data bus for
communications between the processor and RAM.
backup — A copy of a program or data file. As a
precaution, back up your system’s hard drive on a regular
basis. Before making a change to the configuration of your
system, back up important start-up files from your
operating system.
C — Celsius.
backup battery — A battery that maintains system
configuration, date, and time information in a special
section of memory when the system is turned off.
cache — A fast storage area that keeps a copy of data or
instructions for quick data retrieval. When a program
makes a request to a disk drive for data that is in the
cache, the disk-cache utility can retrieve the data from
RAM faster than from the disk drive.
beep code — A diagnostic message in the form of a
pattern of beeps from your system’s speaker. For example,
one beep, followed by a second beep, and then a burst of
three beeps is beep code 1-1-3.
CD — Compact disc. CD drives use optical technology to
read data from CDs.
Glossary
133
cm — Centimeter(s).
DIN — Deutsche Industrie Norm.
cmos — Complementary metal-oxide semiconductor.
directory — Directories help keep related files organized
on a disk in a hierarchical, “inverted tree” structure. Each
disk has a “root” directory. Additional directories that
branch off the root directory are called subdirectories.
Subdirectories may contain additional directories
branching off them.
component — As they relate to DMI, components
include operating systems, computer systems, expansion
cards, and peripherals that are compatible with DMI.
Each component is made up of groups and attributes that
are defined as relevant to that component.
DMA — Direct memory access. A DMA channel allows
certain types of data transfer between RAM and a device
to bypass the processor.
COMn — The device names for the serial ports on your
system.
control panel — The part of the system that contains
indicators and controls, such as the power button and
power indicator.
DMI — Desktop Management Interface. DMI enables
the management of your system’s software and hardware
by collecting information about the system’s components,
such as the operating system, memory, peripherals,
expansion cards, and asset tag.
controller — A chip that controls the transfer of data
between the processor and memory or between the
processor and a peripheral.
DNS — Domain Name System. A method of translating
Internet domain names, such as www.dell.com, into IP
addresses, such as 143.166.83.200.
conventional memory — The first 640 KB of RAM.
Conventional memory is found in all systems. Unless they
®
are specially designed, MS-DOS programs are limited to
DRAM — Dynamic random-access memory. A system’s
running in conventional memory.
RAM is usually made up entirely of DRAM chips.
coprocessor — A chip that relieves the system’s processor
of specific processing tasks. A math coprocessor, for
example, handles numeric processing.
DVD — Digital versatile disc.
ECC — Error checking and correction.
CPU — Central processing unit. See processor.
EEPROM — Electronically erasable programmable read-
only memory.
DC — Direct current.
EMC — Electromagnetic compatibility.
DDR — Double-data rate. A technology in memory
modules that potentially doubles the output.
EMI — Electromagnetic interference.
device driver — A program that allows the operating
system or some other program to interface correctly with a
peripheral. Some device drivers—such as network
drivers—must be loaded from the config.sys file or as
memory-resident programs (usually, from the
ERA — Embedded remote access. ERA allows you to
perform remote, or "out-of-band," server management on
your network server using a remote access controller.
ESD — Electrostatic discharge.
ESM — Embedded server management.
autoexec.bat file). Others must load when you start the
program for which they were designed.
expansion bus — Your system contains an expansion bus
that allows the processor to communicate with controllers
for peripherals, such as NICs.
DHCP — Dynamic Host Configuration Protocol. A
method of automatically assigning an IP address to a
client system.
expansion card — An add-in card, such as a NIC or SCSI
adapter, that plugs into an expansion-card connector on
the system board. An expansion card adds some
diagnostics — A comprehensive set of tests for your
system.
specialized function to the system by providing an
interface between the expansion bus and a peripheral.
DIMM — Dual in-line memory module. See also memory
module.
134
Glossary
expansion-card connector — A connector on the system
headless system — A system or device that functions
without having a keyboard, mouse, or monitor attached.
Normally, headless systems are managed over a network
using an Internet browser.
board or riser board for plugging in an expansion card.
F — Fahrenheit.
FAT — File allocation table. The file system structure
host adapter — A host adapter implements
used by MS-DOS to organize and keep track of file
communication between the system’s bus and the
controller for a peripheral device. (Hard-drive controller
subsystems include integrated host adapter circuitry.) To
add a SCSI expansion bus to your system, you must install
or connect the appropriate host adapter.
®
®
storage. The Microsoft Windows operating systems can
optionally use a FAT file system structure.
flash memory — A type of EEPROM chip that can be
reprogrammed from a utility on diskette while still
installed in a system; most EEPROM chips can only be
rewritten with special programming equipment.
Hz — Hertz.
I/O — Input/output. A keyboard is an input device, and a
monitor is an output device. In general, I/O activity can be
differentiated from computational activity.
format — To prepare a hard drive or diskette for storing
files. An unconditional format deletes all data stored on
the disk.
ID — Identification.
FSB — Front-side bus. The FSB is the data path and
physical interface between the processor and the main
memory (RAM).
IDE — Integrated drive electronics. A standard interface
between the system board and storage devices.
ft — Feet.
integrated mirroring — Provides simultaneous physical
mirroring of two drives. Integrated mirroring functionality
is provided by the system’s hardware. See also mirroring.
FTP — File transfer protocol.
g — Gram(s).
internal processor cache — An instruction and data cache
G — Gravities.
built into the processor.
Gb — Gigabit(s); 1024 megabits or 1,073,741,824 bits.
IP — Internet Protocol.
GB — Gigabyte(s); 1024 megabytes or 1,073,741,824
bytes. However, when referring to hard-drive capacity, the
term is usually rounded to 1,000,000,000 bytes.
IPX — Internet package exchange.
IRQ — Interrupt request. A signal that data is about to be
sent to or received by a peripheral device travels by an IRQ
line to the processor. Each peripheral connection must be
assigned an IRQ number. Two devices can share the same
IRQ assignment, but you cannot operate both devices
simultaneously.
graphics mode — A video mode that can be defined as x
horizontal by y vertical pixels by z colors.
group — As it relates to DMI, a group is a data structure
that defines common information, or attributes, about a
manageable component.
jumper — Small blocks on a circuit board with two or
more pins emerging from them. Plastic plugs containing a
wire fit down over the pins. The wire connects the pins
and creates a circuit, providing a simple and reversible
method of changing the circuitry in a board.
guarding — A type of data redundancy in which a set of
physical drives stores data and an additional drive stores
parity data. See also mirroring, striping, and RAID.
h — Hexadecimal. A base-16 numbering system, often
used in programming to identify addresses in the system’s
RAM and I/O memory addresses for devices. In text,
hexadecimal numbers are often followed by h.
K — Kilo-; 1000.
Kb — Kilobit(s); 1024 bits.
KB — Kilobyte(s); 1024 bytes.
Kbps — Kilobit(s) per second.
Glossary
135
KBps — Kilobyte(s) per second.
MB — Megabyte(s); 1,048,576 bytes. However, when
referring to hard-drive capacity, the term is often rounded
to mean 1,000,000 bytes.
key combination — A command requiring you to press
multiple keys at the same time (for example,
<Ctrl><Alt><Del>).
Mbps — Megabits per second.
MBps — Megabytes per second.
MBR — Master boot record.
kg — Kilogram(s); 1000 grams.
kHz — Kilohertz.
KMM — Keyboard/monitor/mouse.
memory address — A specific location, usually expressed
as a hexadecimal number, in the system’s RAM.
KVM — Keyboard/video/mouse. KVM refers to a switch
that allows selection of the system from which the video
is displayed and for which the keyboard and mouse are
used.
memory module — A small circuit board containing
DRAM chips that connects to the system board.
memory — An area in your system that stores basic system
data. A system can contain several different forms of
memory, such as integrated memory (ROM and RAM)
and add-in memory modules (DIMMs).
LAN — Local area network. A LAN is usually confined to
the same building or a few nearby buildings, with all
equipment linked by wiring dedicated specifically to the
LAN.
MHz — Megahertz.
lb — Pound(s).
mirroring — A type of data redundancy in which a set of
physical drives stores data and one or more sets of
additional drives stores duplicate copies of the data.
Mirroring functionality is provided by software. See also
guarding, integrated mirroring, striping, and RAID.
LCD — Liquid crystal display.
LED — Light-emitting diode. An electronic device that
lights up when a current is passed through it.
Linux — A UNIX-like operating system that runs on a
variety of hardware systems. Linux is open source
software, which is freely available; however, the full
distribution of Linux along with technical support and
training are available for a fee from vendors such as
Red Hat Software.
mm — Millimeter(s).
ms — Millisecond(s).
®
MS-DOS — Microsoft Disk Operating System.
NAS — Network Attached Storage. NAS is one of the
concepts used for implementing shared storage on a
network. NAS systems have their own operating systems,
integrated hardware, and software that are optimized to
serve specific storage needs.
local bus — On a system with local-bus expansion
capability, certain peripheral devices (such as the video
adapter circuitry) can be designed to run much faster than
they would with a traditional expansion bus. See also bus.
NIC — Network interface controller. A device that is
installed or integrated in a system to allow connection to a
network.
LVD — Low voltage differential.
m — Meter(s).
mA — Milliampere(s).
NMI — Nonmaskable interrupt. A device sends an NMI
to signal the processor about hardware errors.
MAC address — Media Access Control address. Your
system’s unique hardware number on a network.
ns — Nanosecond(s).
mAh — Milliampere-hour(s).
NTFS — The NT File System option in the
Windows 2000 operating system.
Mb — Megabit(s); 1,048,576 bits.
136
Glossary
NVRAM — Nonvolatile random-access memory. Memory
that does not lose its contents when you turn off your
system. NVRAM is used for maintaining the date, time,
and system configuration information.
protected mode — An operating mode that allows
operating systems to implement:
• A memory address space of 16 MB to 4 GB
• Multitasking
parity — Redundant information that is associated with a
• Virtual memory, a method for increasing addressable
memory by using the hard drive
block of data.
partition — You can divide a hard drive into multiple
physical sections called partitions with the fdisk
command. Each partition can contain multiple logical
drives. You must format each logical drive with the format
command.
The Windows 2000 and UNIX 32-bit operating systems
run in protected mode. MS-DOS cannot run in protected
mode.
PS/2 — Personal System/2.
PXE — Preboot eXecution Environment. A way of
booting a system via a LAN (without a hard drive or
bootable diskette).
PCI — Peripheral Component Interconnect. A standard
for local-bus implementation.
PDU — Power distribution unit. A power source with
multiple power outlets that provides electrical power to
servers and storage systems in a rack.
RAC — Remote access controller.
RAID — Redundant array of independent disks. A
method of providing data redundancy. Some common
implementations of RAID include RAID 0, RAID 1,
RAID 5, RAID 10, and RAID 50. See also guarding,
mirroring, and striping.
peripheral — An internal or external device, such as a
diskette drive or keyboard, connected to a system.
PGA — Pin grid array. A type of processor socket that
allows you to remove the processor chip.
RAM — Random-access memory. The system’s primary
temporary storage area for program instructions and data.
Any information stored in RAM is lost when you turn off
your system.
pixel — A single point on a video display. Pixels are
arranged in rows and columns to create an image. A video
resolution, such as 640 x 480, is expressed as the number
of pixels across by the number of pixels up and down.
RAS — Remote Access Service. This service allows users
running the Windows operating system to remotely access
a network from their system using a modem.
POST — Power-on self-test. Before the operating system
loads when you turn on your system, the POST tests
various system components such as RAM and hard drives.
readme file — A text file, usually shipped with software or
hardware, that contains information supplementing or
updating the product’s documentation.
processor — The primary computational chip inside the
system that controls the interpretation and execution of
arithmetic and logic functions. Software written for one
processor must usually be revised to run on another
processor. CPU is a synonym for processor.
read-only file — A read-only file is one that you are
prohibited from editing or deleting.
ROM — Read-only memory. Your system contains some
programs essential to its operation in ROM code. A ROM
chip retains its contents even after you turn off your
system. Examples of code in ROM include the program
that initiates your system’s boot routine and the POST.
Glossary
137
ROMB — RAID on motherboard.
rpm — Revolutions per minute.
RTC — Real-time clock.
striping — Disk striping writes data across three or more
disks in an array, but only uses a portion of the space on
each disk. The amount of space used by a "stripe" is the
same on each disk used. A virtual disk may use several
stripes on the same set of disks in an array. See also
guarding, mirroring, and RAID.
SAS — Serial-attached SCSI.
SATA — Serial Advanced Technology Attachment. A
standard interface between the system board and storage
devices.
SVGA — Super video graphics array. VGA and SVGA are
video standards for video adapters with greater resolution
and color display capabilities than previous standards.
SCSI — Small computer system interface. An I/O bus
interface with faster data transmission rates than standard
ports.
system board — As the main circuit board, the system
board usually contains most of your system’s integral
components, such as the processor, RAM, controllers for
peripherals, and various ROM chips.
SDRAM — Synchronous dynamic random-access
memory.
system configuration information — Data stored in
memory that tells a system what hardware is installed and
how the system should be configured for operation.
sec — Second(s).
serial port — An I/O port used most often to connect a
modem to your system. You can usually identify a serial
port on your system by its 9-pin connector.
system diskette — See bootable diskette.
system memory — See RAM.
service tag — A bar code label on the system used to
System Setup program — A BIOS-based program that
allows you to configure your system’s hardware and
customize the system’s operation by setting features such
as password protection. Because the System Setup
program is stored in NVRAM, any settings remain in
effect until you change them again.
identify it when you call Dell for technical support.
simple disk volume — The volume of free space on a
single dynamic, physical disk.
SMART — Self-Monitoring Analysis and Reporting
Technology. Allows hard drives to report errors and failures
to the system BIOS and then display an error message on
the screen.
system.ini file — A start-up file for the Windows
operating system. When you start Windows, it consults
the system.ini file to determine a variety of options for the
Windows operating environment. Among other things,
the system.ini file records which video, mouse, and
keyboard drivers are installed for Windows.
SMP — Symmetric multiprocessing. Used to describe a
system that has two or more processors connected via a
high-bandwidth link and managed by an operating
system, where each processor has equal access to I/O
devices.
TCP/IP — Transmission Control Protocol/Internet
SNMP — Simple Network Management Protocol. A
standard interface that allows a network manager to
remotely monitor and manage workstations.
Protocol.
termination — Some devices (such as the last device at
each end of a SCSI cable) must be terminated to prevent
reflections and spurious signals in the cable. When such
devices are connected in a series, you may need to enable
or disable the termination on these devices by changing
jumper or switch settings on the devices or by changing
settings in the configuration software for the devices.
spanning — Spanning, or concatenating, disk volumes
combines unallocated space from multiple disks into one
logical volume, allowing more efficient use of all the space
and all drive letters on a multiple-disk system.
138
Glossary
TOE — TCP/IP offload engine. A technology to improve
data-transfer performance over IP networks by allowing
the operating system to offload all TCP/IP traffic to
specialized hardware on the network adapter, while
leaving TCP/IP control decisions to the host server.
video memory — Most VGA and SVGA video adapters
include memory chips in addition to your system’s RAM.
The amount of video memory installed primarily
influences the number of colors that a program can
display (with the appropriate video drivers and monitor
capabilities).
UNIX — Universal Internet Exchange. UNIX, the
precursor to Linux, is an operating system written in the
C programming language.
video resolution — Video resolution (800 x 600, for
example) is expressed as the number of pixels across by
the number of pixels up and down. To display a program
at a specific graphics resolution, you must install the
appropriate video drivers and your monitor must support
the resolution.
uplink port — A port on a network hub or switch used to
connect to other hubs or switches without requiring a
crossover cable.
UPS — Uninterruptible power supply. A battery-powered
unit that automatically supplies power to your system in
the event of an electrical failure.
W — Watt(s).
WH — Watt-hour(s).
USB — Universal Serial Bus. A USB connector provides a
single connection point for multiple USB-compliant
devices, such as mice and keyboards. USB devices can be
connected and disconnected while the system is running.
win.ini file — A start-up file for the Windows operating
system. When you start Windows, it consults the win.ini
file to determine a variety of options for the Windows
operating environment. The win.ini file also usually
includes sections that contain optional settings for
Windows application programs that are installed on the
hard drive.
utility — A program used to manage system resources—
memory, disk drives, or printers, for example.
UTP — Unshielded twisted pair. A type of wiring used to
Windows 2000 — An integrated and complete Microsoft
Windows operating system that does not require
MS-DOS and that provides advanced operating system
performance, improved ease of use, enhanced workgroup
functionality, and simplified file management and
browsing.
connect systems in a business or home to a telephone line.
V — Volt(s).
VAC — Volt(s) alternating current.
VDC — Volt(s) direct current.
VGA — Video graphics array. VGA and SVGA are video
standards for video adapters with greater resolution and
color display capabilities than previous standards.
Windows Powered — A Windows operating system
designed for use on NAS systems. For NAS systems, the
Windows Powered operating system is dedicated to file
service for network clients.
video adapter — The logical circuitry that provides (in
combination with the monitor) your system’s video
capabilities. A video adapter may be integrated into the
system board or may be an expansion card that plugs into
an expansion slot.
Windows Server 2003 — A set of Microsoft software
technologies that enable software integration through the
use of XML Web services. XML Web services are small
reusable applications written in XML that allow data to be
communicated between otherwise unconnected sources.
video driver — A program that allows graphics-mode
application programs and operating systems to display at a
chosen resolution with the desired number of colors.
Video drivers may need to match the video adapter
installed in the system.
XML — Extensible Markup Language. XML is a way to
create common information formats and to share both the
format and the data on the World Wide Web, intranets,
and elsewhere.
ZIF — Zero insertion force.
Glossary
139
140
Glossary
contacting, 112
Numerics
C
3.5-inch drive
removing, 44
cable clamp, 70
CD/DVD drive
installing, 49
5.25-inch drive
removing, 47
DIMM
installing, 72
sockets, 58
A
diskette drive
installing, 45
removing, 71
admin password
assigning, 37
changing, 38
deleting, 38
using, 37
replacing, 72
removing, 44
replacing, 45
troubleshooting, 89
connecting external
devices, 13
DVD drive. See CD/DVD
connectors, 103
back-panel, 13
front-panel, 11
NICs, 13
B
E
battery
installing, 67
removing, 67
troubleshooting, 85
serial port, 13
USB, 11, 13
video, 13
expansion cards, 56
installing, 57
bezel
cooling fans
installing, 67
removing, 56
installing, 74
removing, 73
replacing, 74
replacing, 57
removing, 65
replacing, 67
troubleshooting, 93
bezel (front drive)
insert, 43
removing, 42
replacing, 43
D
F
damaged systems
troubleshooting, 84
features
back-panel, 13
Index
141
tape drive, 49
N
IRQs
line assignments, 80
NICs
connectors, 13
indicators, 14
troubleshooting, 83
H
hard drive
installing, 52
removing, 51
J
jumpers, 101
opening the system, 41
options
I
K
I/O panel
keyboard
installing, 76
removing, 74
replacing, 76
password
indicators
admin, 37
back-panel, 13
front-panel, 11
NIC, 14
disabling, 38, 104
features, 35
memory
4-GB configurations, 59
branches, 58
insert on front drive bezel
removing, 43
channels, 58
POST
installing, 60
accessing system features, 10
replacing, 44
removing, 60
installing, 70
replacing, 60
installing
troubleshooting, 87
upgrade kits, 59
5.25-inch drive, 49
bezel, 74
removing, 69
replacing, 70
CD/DVD drive, 49
chassis intrusion switch, 72
cooling fans, 67
diskette drive, 45
expansion cards, 57
hard drive, 52
troubleshooting, 86
alert, 26
processor
system, 16
installing, 65
removing, 62
troubleshooting, 95
warning, 25
microprocessor
removing, 62
I/O panel, 76
memory, 60
replacing, 65
power supply, 70
processor, 65
troubleshooting, 95
R
mouse
system battery, 67
system board, 78
recommended tools, 39
troubleshooting, 81
142
Index
removing
SAS hard drive. See hard
3.5-inch drive, 44
bezel, 73
drive.
system password features, 35
CD/DVD drive, 47
chassis intrusion switch, 71
cooling fans, 65
diskette drive, 44
expansion cards, 56
front drive bezel, 42
hard drive, 51
system setup program
entering, 27
options, 28
using, 27
connector, 13
troubleshooting, 82
system setup screens
drive options, 30
setup password features, 35
main, 28
I/O panel, 74
maintenance options, 34
onboard devices options, 31
performance options, 31
POST behavior options, 34
power management
options, 33
memory, 60
accessing system features, 10
power supply, 69
processor, 62
system battery, 67
system board, 76
tape drive, 47
support
security options, 32
replacing
system
bezel, 74
chassis intrusion switch, 72
cooling fans, 67
diskette drive, 45
expansion cards, 57
front drive bezel, 43
I/O panel, 76
removing, 67
T
system board
connectors, 103
installing, 78
jumpers, 101
replacing, 78
installing, 49
removing, 47
troubleshooting, 91
memory, 60
power supply, 70
troubleshooting
CD/DVD drive, 90
cooling fans, 87
damaged system, 84
diskette drive, 89
expansion cards, 93
external connections, 80
hard drive, 91
system board, 78
system cooling
troubleshooting, 86
S
accessing, 10
safety, 79
system messages, 16
SAS controller card
installing, 58
keyboard, 81
system password
assigning, 35
memory, 87
troubleshooting, 92
microprocessor, 95
mouse, 81
changing, 37
Index
143
NIC, 83
power supply, 86
SAS controller card, 92
serial port, 82
start-up routine, 79
system battery, 85
system cooling, 86
tape drive, 91
USB device, 82
video, 81
U
upgrade kits
memory, 59
USB device
connectors (back panel), 13
connectors (front panel), 11
V
video
W
warning messages, 25
warranty, 9
wet system
troubleshooting, 84
144
Index
|