Bloomfield WVOC 2HSG User Manual

505  
WELLS MANUFACTURING COMPANY  
2 ERIK CIRCLE, P. O. Box 280  
Verdi, NV 89439  
Customer Service (775) 345-0444 Ext.502  
fax: (775) 345-0569  
OPERATION MANUAL  
WVOC-2 SERIES  
CONVECTION OVEN  
and  
COMBO COOK CENTER  
with  
UNIVERSAL HOOD  
WVOC-2HFG  
WVOC-2HSG  
Includes  
INSTALLATION  
USE & CARE  
Model  
WVOC-2HFG  
IMPORTANT: DO NOT DISCARD THIS MANUAL  
This manual is considered to be part of the appliance and is to be given to the OWNER or  
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of  
this appliance. Additional manuals are available from your WELLS DEALER.  
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR  
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any  
questions concerning installation, operation or maintenance of this equipment.  
p/n 304963 Rev. (-)  
M505 031102 cps  
TABLE OF CONTENTS  
WARRANTY  
SPECIFICATIONS  
xi  
1
FEATURES & OPERATING CONTROLS  
PRECAUTIONS & GENERAL INFORMATION  
AGENCY LISTING INFORMATION  
INSTALLATION  
2
6
7
8
OPERATION  
13  
18  
22  
23  
26  
28  
31  
31  
CLEANING INSTRUCTIONS  
TROUBLESHOOTING SUGGESTIONS  
MAINTENANCE INSTRUCTIONS  
MSDS (Ansulex Low pH)  
MAINTENANCE SCHEDULES  
PARTS & SERVICE  
CUSTOMER SERVICE DATA  
INTRODUCTION  
Thank You for purchasing this Wells Manufacturing Co. appliance.  
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it  
gives you the very best performance and a long, economical service life.  
This manual contains the information needed to properly install this appliance, and to use and care for the  
appliance in a manner which will ensure its optimum performance.  
SPECIFICATIONS  
AMPS 3ø  
MODEL  
VOLTS  
208  
WATTS  
12,800  
15,500  
13,700  
16,700  
L1  
37  
39  
41  
44  
L2  
36  
37  
38  
39  
L3  
33  
36  
35  
38  
AMPS 1ø  
n/a  
WVOC-2HFG  
240  
n/a  
WVOC-2HSG  
208  
n/a  
240  
n/a  
Minimum clearances required from unit to nearest combustible surface or object.  
BACK  
n/a  
SIDE  
6
BOTTOM  
TOP  
19  
inches  
6
millimeters  
n/a  
152  
152  
483  
1
FEATURES & OPERATING CONTROLS  
Fig. 1 Ventilator Section Operating Features & Controls  
2
FEATURES & OPERATING CONTROLS (continued)  
VENTILATOR SECTION  
ITEM  
DESCRIPTION  
COMMENT  
1.  
NAMEPLATE  
Gives manufacturer, make and model description. Also lists voltage  
and amperage data.  
a6.  
FIRE SUPPRESSION  
AGENT TANK (1.5 gal.)  
Container for Ansulex™ Low-pH liquid fire suppression liquid.  
8.  
9.  
ADJUSTABLE (FRONT) LEG  
RIGID (REAR) CASTER  
Allows the unit to be leveled.  
Allows the unit to be easily positioned by lifting the front of the unit  
slightly.  
a10.  
a11.  
12.  
MANUAL PULL STATION  
FUSIBLE LINKS  
Provides a means of manual activation of the fire suppression system.  
PULL ONLY IN CASE OF FIRE!  
Automatically activates fire suppression system in the event of fire on  
the cooktop.  
LOWER REAR ACCESS  
PANEL  
Allows access to Ansul® fire suppression agent tank (a6) and controls  
also access to main power contactor (41).  
a15.  
16.  
DISCHARGE NOZZLE  
GREASE BAFFLE  
Fire suppression media discharges here (2 places).  
Extracts and drains most grease and moisture from the air flow.  
18.  
PRE-FILTER ASSEMBLY  
Comprises the PRE-FILTER FRAME and a replaceable  
PRE-FILTER. Stops larger particles of grease from reaching the  
FILTER PACK for reduced maintenance costs.  
19.  
HEPA/CHARCOAL FILTER  
PACK  
Stops most grease and smoke particles. Also assists in some cooking  
odor removal.  
22.  
23.  
28.  
GREASE CUP  
Collects grease/moisture drained from grease trough (23).  
GREASE TROUGH  
Directs grease/moisture removed by grease baffle to grease cup.  
VENTILATOR EXHAUST  
DUCT  
Exit point for ventilator airflow - on top left rear of unit.  
DO NOT BLOCK  
a31.  
STATUS INDICATOR  
Displays status of fire suppression system (COCKED - FIRED) If  
FIRED, a buzzer will sound continuously.  
38.  
40.  
41.  
POWER CORD  
FUSES  
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).  
Provide over-current protection.  
POWER CONTACTOR  
Energizes cooking appliances only while ventilator section is sensed  
as operational.  
42.  
BUILDING FIRE ALARM  
RELAY  
Reports fire alarm condition to building fire management system.  
43.  
44.  
GROUND LUG  
Ground wire of power cord connects here.  
INTERLOCK TERMINAL  
Provides connection for shut-down control by building fire management  
system.  
53.  
FILTER INTERLOCK  
SWITCHES  
Proper installation of grease baffle and filter pack close these switches  
in ventilator sensor circuit.  
56.  
57.  
58.  
VENTILATOR FAN  
HOOD SIDE SHIELD  
SIDE SPACERS  
Provides air movement for ventilation.  
Required on left and right sides of hood. Factory installed.  
Required to maintain 6" spacing from combustibles. Field installed.  
3
FEATURES & OPERATING CONTROLS (continued)  
V2  
V3  
V4  
V5  
V6  
V1  
Fig. 2 Ventilator Section Controls & Indicator Lights  
Fig. 4 Control Panel  
Fig. 3 Cooking Section  
4
FEATURES & OPERATING CONTROLS (continued)  
ITEM  
DESCRIPTION  
COMMENT  
VENTILATOR SECTION CONTROLS  
V1  
POWER SWITCH  
Energizes blower motor. If, after 10 seconds, proper conditions  
are met, cooking appliances are energized.  
V2  
V3  
POWER ON INDICATOR  
GREEN. Glows when POWER switch is ON.  
CHECK FILTERS ALARM IN-  
DICATOR  
AMBER. Glows if one or more filters are out of position. Check all  
filters and baffles for proper installation.  
V4*  
V5*  
V6*  
REPLACE PREFILTER  
ALARM INDICATOR  
AMBER. Glows when PREFILTER is approaching the end of its  
service life and must soon be replaced.  
REPLACE FILTER PACK  
ALARM INDICATOR  
AMBER. Glows when FILTER PACK is approaching the end of its  
service life and must soon be replaced.  
SERVICE REQUIRED ALARM  
INDICATOR  
RED. Glows when PREFILTER and/or FILTER PACK has reached  
the end of its service life and is too loaded to allow sufficient air flow.  
Filter MUST be replaced. Appliance is SHUT DOWN until expended  
filters are replaced.  
*
See PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding  
prefilters and filter packs.  
COOKING APPLIANCE CONTROLS  
G.01  
GRIDDLE TEMPERATURE  
CONTROL  
Thermostat control of griddle temperature  
G.02  
GRIDDLE HEAT INDICATOR  
Glows when heating elements are energized.  
H.01  
FRONT HOTPLATE  
Infinite switch control of temperature of front hotplate.  
TEMPERATURE CONTROL  
H.02  
H.03  
HOTPLATE "ON" INDICATOR  
AMBER. Glows when front hotplate control is turned ON.  
REAR HOTPLATE  
Infinite switch control of temperature of front hotplate.  
TEMPERATURE CONTROL  
H.04  
HOTPLATE "ON" INDICATOR  
AMBER. Glows when rear hotplate control is turned ON.  
C.01  
C.02  
C.03  
C.04  
C.05  
POWER-OFF-FAN SWITCH  
FAN LOW-OFF-HIGH SWITCH  
OVEN POWER INDICATOR  
HEAT INDICATOR  
Switch to turn oven ON, OFF, or select FAN only.  
Switch to turn fan ON, and to select fan speed.  
AMBER. Glows when oven is turned ON.  
AMBER. Glows when heating elements are energized.  
DIGITAL DISPLAY  
Displays time and temperature information.  
A. Time remaining in program (minute : second)  
B. Programmed temperature (ºF)  
C.06  
C.07  
C.08  
C.09  
C.10  
C.11  
OVEN TIME CONTROL  
OVEN TEMP CONTROL  
START TIMER KEY  
ACTUAL TEMP KEY  
PGM KEYS  
Adjust programmed cooking time.  
Adjust programmed cooking temperature.  
Begin a timed cook cycle.  
Press to display current oven temperature.  
Press to select pre-programmed time/temperature.  
Press to cancel a program in progress.  
CANCEL KEY  
5
PRECAUTIONS AND GENERAL INFORMATION  
NOTE: Fire suppression system and all associated components must  
only be serviced by an authorized Ansul® Distributor. All setup,  
charging, repair and/or adjustment of the fire suppression system must  
be performed by an Authorized Ansul® Distributor ONLY.  
WARNING:  
Electric  
Shock hazard  
IMPORTANT: If a remote pull station is installed, both rear casters (9)  
must be replaced with legs to deter moving the unit. MOVING AN  
APPLIANCE WITH A REMOTE PULL STATION WILL DISCHARGE  
THE FIRE SUPPRESSION SYSTEM.  
All servicing requiring  
access to non-insulated  
electrical components  
must be performed by a  
factory authorized  
This Ventless Cooking System™ is designed to help reduce odor  
emissions, but will not completely eliminate cooking odors. Air  
exchange at the installation site must comply with the requirements of  
the local jurisdictional authority. To ensure that odors do not build-up,  
recommended minimum air exchange is 300 - 400 cfm of outside air  
into and out of the area where the unit is used. Recommend use of  
wall fan and wall switch, to be supplied by user.  
technician.  
DO NOT open any access  
panel which requires the  
use of tools. Failure to  
follow this warning can  
result in severe electrical  
shock.  
This appliance is intended for use in commercial establishments  
only.  
This appliance is intended to prepare food for human consumption.  
No other use is recommended or authorized by the manufacturer or its  
agents.  
CAUTION:  
Risk of  
Damage  
Operators of this appliance must be familiar with the appliance use,  
limitations and associated restrictions. Operating instructions must be  
read and understood by all persons using or installing this appliance.  
DO NOT connect or  
energize this appliance  
until all installation  
instructions are read and  
followed. Damage to the  
appliance will result if  
these instructions are not  
followed.  
Cleanliness of this appliance is essential to good sanitation. Read and  
follow all included cleaning instructions and schedules to ensure the  
safety of the food product.  
Disconnect this appliance from electrical power before performing any  
maintenance or servicing.  
Do not splash or pour water on, in or over any exposed element,  
control, control panel or wiring.  
DANGER  
DO NOT submerge pre-filter or filter pack in water.  
ELECTRIC SHOCK HAZARD  
The technical content of this manual, including any wiring diagrams,  
schematics, parts breakdown illustrations and/or adjustment  
procedures, is intended for use by qualified technical personnel.  
Any procedure which requires the use of tools must be performed by a  
qualified technician.  
This manual is considered to be a permanent part of the appliance.  
This manual and all supplied instructions, diagrams, schematics, parts  
breakdown illustrations, notices and labels must remain with the  
appliance if it is sold or moved to another location.  
DO NOT SPRAY WATER ON OR AROUND  
ELECTRICAL EQUIPMENT  
DO NOT WASH FLOOR NEAR ELECTRICAL  
EQUIPMENT WITH WATER SPRAY  
This appliance is made in the USA. Unless otherwise noted, this  
appliance has American sizes on all hardware.  
6
PRECAUTIONS AND GENERAL INFORMATION (continued)  
OPERATIONAL NOTES:  
REPLACE PREFILTER and REPLACE FILTER PACK indicator lights  
provide a timely warning that a system shut-down is imminent.  
The actual time between the indicator light coming on and the loss of  
cooking appliance power will depend upon the cooking conditions.  
Anytime a dirty PRE-FILTER is replaced, the system airflow will  
increase. If the condition of the FILTER PACK is marginal, the  
REPLACE FILTER PACK light could then come on. If this happens,  
a fresh FILTER PACK must be installed within a reasonably short time.  
Loss of airflow through the old filter pack will soon cause a system  
shut-down when the airflow falls below minimum vapor capture levels.  
KEEP A SPARE FILTER PACK ON HAND.  
IMPORTANT: If you decide to “get the most” out of the old filter pack,  
and continue to use it until a system shut-down happens, it is advisable  
to have a fresh filter pack readily at hand, and have someone available  
who is capable of replacing it. Otherwise, you may experience an  
extended down time, with consequent associated loss of business.  
The manufacturer assumes no liability for loss of business due to  
a system shutdown caused by a dirty pre-filter and/or filter pack  
(i.e. red SERVICE REQUIRED light is on), when the user fails to  
have the proper replacement pre-filter and/or filter pack on hand.  
The Ventless Cooking System™ hood is designed as part of a WELLS  
cooking appliance only. No other use of this product is authorized by  
the manufacturer or its agents. Wells Mfg. assumes no liability for the  
use of this equipment with products by any other manufacturer’s, or for  
use of this equipment with any Wells Manufacturing product other than  
in factory certified applications.  
Fig. 5 Ventilator  
Warning  
Indicators  
AGENCY LISTING INFORMATION  
This appliance conforms to NSF Standard 4 for sanitation only if  
installed in accordance with the supplied Installation Instructions  
And operated and maintained in accordance with the instructions  
in this manual.  
This appliance is  
Listed under UL File E146882.  
E146882  
STD 4  
7
INSTALLATION  
NOTE: DO NOT discard  
the carton or other packing  
materials until you have  
inspected the appliance for  
hidden damage and tested it  
for proper operation.  
UNPACKING & INSPECTION  
Carefully remove the appliance from the carton. Remove all  
protective plastic film, packing materials and accessories from the  
Appliance before connecting electrical power or otherwise performing  
any installation procedure.  
Refer to SHIPPING DAMAGE  
CLAIM PROCEDURE on the  
inside front cover of this  
manual.  
Carefully read all instructions in this manual and the Installation  
Instruction Sheet packed with the appliance before starting any  
installation.  
Read and understand all labels and diagrams attached to the  
appliance.  
WARNING:  
Risk of  
personal injury  
Carefully account for all components and accessories before  
discarding packing materials. Store these components in or near the  
appliance for later use. These items must be installed before operating  
the appliance.  
Installation procedures must  
be performed by a qualified  
technician with full knowledge  
of all applicable electrical  
codes. Failure can result in  
personal injury and property  
damage.  
1 ea. FIRE SUPPRESSION AGENT (ANSULEX® Low pH, 1.5 GAL.)  
See Material Safety Data Sheet, page 26.  
1 ea. FIRE SUPPRESSION MEDIA TANK  
1 ea. FIRE SUPPRESSION TANK CHARGING CARTRIDGE  
1 ea. GREASE BAFFLE  
1 ea. FILTER PACK ASSEMBLY  
1 ea. PRE-FILTER HOLDER with PRE-FILTER  
1 ea. GREASE CUP  
WARNING:  
Fire Hazard  
1 ea. GREASE TROUGH  
2 ea. 6” SIDE SPACERS  
1 ea. LITERATURE PACKAGE  
Additionally:  
1 ea. FAN BAFFLE  
Avoid storing flammable or  
combustible materials near  
the appliance.  
2 ea. RACK SUPPORTS  
3 ea. CONVECTION OVEN RACKS  
SETUP  
Setup the appliance only on a firm level surface. Non-combustible  
material is recommended.  
Refer to the Installation Instruction Sheet for required clearances.  
Maintain required clearances between the appliance and adjacent  
combustible surfaces. Verify 6” left and right side clearances to  
combustible construction. This appliance requires a minimum of 8 ft  
(96”) (floor to overhead) to allow for adequate exhaust.  
IMPORTANT: Provided 6" side spacers (item 58) must be installed on  
the appliance.  
Factory installed side shields (item 57) are required.  
Verify that the VENTILATOR HOOD ASSEMBLY is properly and  
securely assembled to the cooking appliance before beginning the  
installation procedure.  
If a remote manual pull station is to be installed, replace the rear  
casters with legs.  
Level the unit after it is in its final position. Using a spirit level, verify  
that the unit is level front-to-back and side-to-side.  
8
INSTALLATION (continued)  
SERVICE TECHNICIAN INSTALLATION NOTES  
IMPORTANT!  
Verify that this VENTILATOR  
and food cooking equipment  
installation is in compliance  
with the specifications listed  
in this manual, with local  
code requirements, and in  
accordance with N.F.P.A 96  
(THE STANDARD FOR  
VENTILATION CONTROL  
AND FIRE PROTECTION  
OF COMMERCIAL  
An Ansul® technician must charge and arm the fire suppression system  
before the ventilator blower will operate. See page 10.  
Installation and start up must be performed by an Authorized  
Installation Company.  
Installer must complete the WARRANTY REGISTRATION form, and  
record appliance installation particulars on the CUSTOMER SERVICE  
DATA form in this manual.  
Certain codes require cooking equipment to be restrained with a  
RESTRAINT DEVICE. It is the RESPONSIBILITY OF THE  
INSTALLER to check with the AUTHORITY HAVING JURISDICTION,  
in order to ascertain the applicability of this requirement to THIS  
SPECIFIC EQUIPMENT INSTALLATION. Any restraint device must  
allow access to the back and sides of the unit to provide for servicing  
and maintenance, and must not interfere with the operation of the FIRE  
SUPPRESSION SYSTEM.  
COOKING OPERATIONS -  
current edition).  
THIS IS THE  
RESPONSIBILITY  
OF THE INSTALLER  
DANGER  
ELECTRIC  
SHOCK  
ELECTRICAL INSTALLATION  
1. This appliance must be installed by a licensed electrician in  
accordance with all applicable codes and ordinances.  
Electrical connection terminal block and ground lug are accessible  
by removing the right side panel.  
HAZARD  
ELECTRIC CONNECTIONS  
MUST BE MADE BY A  
LICENSED ELECTRICIAN  
Electrical shock will cause  
death or serious injury.  
2. Refer to the nameplate on the right side of the appliance. Verify the  
ELECTRICAL SERVICE POWER. Voltage and phase must match  
the nameplate specifications, and available electrical service  
amperage must meet or exceed the specifications listed on page 1  
Wiring must be no less than 4 AWG solid copper wire, rated for at  
least 90ºC.  
CAUTION:  
Electrical Shock  
Hazard  
NOTE: Wire gauge, insulation type and temperature rating , as  
well as type, size and construction of conduit, must meet or exceed  
applicable specifications of local codes and of the National  
Electrical Code.  
The ground lug of this  
appliance must be connected  
to a suitable building ground.  
NOTE: This appliance  
requires a dedicated 60 Amp  
electrical branch circuit  
protection.  
3. This appliance must be connected to a suitable building ground.  
The equipment ground connection is marked "  
".  
4. The appliance is shipped from the factory wired for 3-phase  
electrical service. Refer to the Wiring Diagram included with this  
appliance, and verify that field wiring conforms to this diagram.  
IMPORTANT:  
Contact a licensed electrician  
to install and connect  
electrical power to the  
appliance.  
IMPORTANT: This appliance is not approved for 1Ø operation.  
Conversion of this appliance to single-phase operation will void the  
warranty.  
IMPORTANT:  
Damage due to being  
connected to the wrong  
voltage or phase is NOT  
covered by warranty.  
9
INSTALLATION (continued)  
DANGER  
FIRE SUPPRESSION SYSTEM INSTALLATION  
FIRE HAZARD  
1. Any REMOTE MANUAL PULL STATION must be installed by an  
authorized ANSUL® distributor in accordance with the  
AUTHORITY HAVING JURISDICTION.  
NOTE: If a REMOTE MANUAL PULL STATION is installed, moving  
the unit for servicing will cause the Ansul® system to discharge. In  
this case, the unit must only be installed with four fixed legs  
(i.e. remove rear casters and replace with legs). Additional legs may  
be ordered through an Authorized Wells Service Agency. See page 31.  
2. The FIRE SUPPRESSION SYSTEM is comprised of a  
pressurized cartridge &  
THE FIRE SUPPRESSION  
SYSTEM MUST BE  
container of liquid fire  
suppressant, with  
CHARGED AND CERTIFIED  
BY AN AUTHORIZED  
ANSUL® DISTRIBUTOR.  
NEVER ATTEMPT TO  
MODIFY OR BYPASS THE  
FIRE SUPPRESSION  
SYSTEM.  
AN UNCONTROLLED FIRE  
CAN CAUSE SERIOUS  
INJURY, DEATH AND/OR  
PROPERTY LOSS.  
associated plumbing and  
controls. It utilizes factory  
installed FUSIBLE LINKS  
for automatic actuation,  
and a factory installed  
MANUAL PULL STATION  
for manual actuation.  
Two NOZZLES are used  
to disperse the liquid fire  
suppression media.  
IMPORTANT: The FIRE  
SUPPRESSION SYSTEM  
must be SET-UP and  
CHARGED by an authorized  
Ansul® distributor before the  
ventilator blower will operate.  
3. When the fire suppression  
system activates, the fire  
suppression media is  
discharged, both the  
cooking appliance and the  
ventilator are de-energized,  
and a buzzer will sound  
continuously.  
The fire suppression media  
will form an emulsion  
NOTE: If the fire suppression  
system is discharged, a  
buzzer will sound continu-  
ously and the cooking appli-  
ance will remain inoperable  
until the fire suppression sys-  
tem is serviced. Recharging  
and resetting must be per-  
formed by an authorized  
Ansul® distributor ONLY.  
Fig. 6 Fire Suppression System  
designed to both smother  
and cool the fire.  
Call your Authorized Ansul® Distributor immediately for  
service.  
NOTE: See page 26 for the Material Safety Data Sheet for the fire  
suppression agent.  
Charging of the Ansul Fire  
Suppression system must be  
in accordance with Ansul®  
Design, Installation, Recharge  
and Maintenance Manual.  
(Ansul® #418087-05)  
4. The MANUAL PULL STATION and any similar REMOTE MANUAL  
PULL STATION will activate the fire suppression system when the  
ring on the pull station is pulled horizontally.  
10  
INSTALLATION (continued)  
NOTE:  
FILTERS INSTALLATION  
The GREASE BAFFLE and  
FILTER PACK activate  
mechanical switches, and the  
PRE-FILTER activates a  
vacuum switch, to verify that  
the filter elements are in their  
proper positions.  
All filter elements must be  
properly installed or the  
cooking appliances will not  
be energized. Also, the  
CHECK FILTERS indicator  
will light.  
1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is  
not in position, the CHECK FILTERS indicator will light.  
If the FILTER PACK becomes clogged, the REPLACE FILTER  
PACK indicator will glow.  
To install the FILTER PACK: Position the filter pack with the  
charcoal portion UP. Slide the filter pack toward the rear of the unit  
until it contacts the guides on the back panel. Push the filter pack  
UP into the upper opening until it rests firmly against the filter pack  
seal. When up in position, holder clips can be snapped over wall  
ledge on each side. To remove FILTER PACK: Grasp both holder  
clips and pull INWARD until the clips clear the sidewall ledge. Then,  
pull the filter pack down and out.  
2. PRE-FILTER: The PRE-FILTER ships in the FILTER FRAME. If  
the PRE-FILTER is not in position, or if the PRE-FILTER is not in  
the FILTER FRAME, the CHECK FILTERS indicator will light. If the  
PRE-FILTER becomes clogged, the REPLACE PRE-FILTER  
indicator will glow.  
IMPORTANT:  
The filter hook prevents the  
PRE-FILTER from being  
drawn in during operation.  
After installation, press  
against the top of the filter  
frame to verify proper  
engagement of the filter hook  
over the lip of the top filter  
rail.  
To install the PRE-FILTER: Pay attention to the air flow markings.  
The AIR FLOW arrow will point away from the installer. Slide the  
assembly up into the front opening, behind the upper filter rail.  
While pressing slightly against the bottom of the assembly, pull the  
FILTER HANDLE toward you so as to engage the FILTER HOOK  
over the lip of the top filter rail. Then lower and seat the assembly  
into the top indentation of the lower filter rail.  
3. GREASE BAFFLE: If the GREASE BAFFLE is not in place, the  
CHECK FILTERS indicator will glow.  
To install the GREASE BAFFLE: Slide the grease baffle up into the  
indentation of the upper filter rail, then lower and seat it into the  
bottom indentation of the lower filter rail. Pull toward you and  
downward to verify the GREASE BAFFLE is properly seated in the  
lower frame rail.  
SEAL  
FILTER PACK  
FILTER PACK  
POSITION  
SWITCH  
PRE-FILTER  
NOTE: AIR FLOW ARROW  
POINTS AWAY FROM  
INSTALLER WHEN  
HOLDER CLIP  
CLIPS ONTO  
FILTER PACK  
SEAL  
LEDGE  
PROPERLY INSTALLED  
FILTER PACK  
HOLDER CLIP  
FILTER HOOK  
GREASE BAFFLE  
POSITION  
SWITCH  
FILTER  
HOOK  
PRE-FILTER  
ASSEMBLY  
FILTER  
RAIL  
GREASE  
BAFFLE  
FILTER  
HANDLE  
GREASE  
TROUGH  
FILTER  
FRAME  
GREASE  
CUP  
NOTE: PRE-FILTER IS SENSED  
AS BEING IN POSITION BY THE  
PRESSURE DROP ACROSS IT.  
Fig. 7 Filter Installation  
11  
INSTALLATION (continued)  
WARNING  
Slipping / Falling  
Hazard  
GREASE TROUGH AND GREASE CUP INSTALLATION  
1. Install the GREASE TROUGH into the brackets below the grease  
baffle.  
Spilled Oil  
2. Install the GREASE CUP on the right side of the unit, directly  
below the grease trough.  
HOTPLATE DRIP PAN INSTALLATION (SPIRAL  
HEATING ELEMENTS ONLY)  
1. Lift / rotate the  
elements up.  
Element Support  
2. Install a drip  
Drip Pan  
pan in each  
DO NOT OPERATE UNLESS  
THE GREASE CUP IS  
element cutout.  
Heating Element  
INSTALLED.  
(Lifted)  
3. Install an  
Oil and moisture will drip onto  
the floor and falls may result.  
Death or serious injury may  
result from slipping and falling  
element  
support into  
each drip pan.  
The ends of the  
Fig. 8 Hotplate Drip Pan Installation  
support set in the indentations in the pan. The support’s center  
boss must be on the top.  
CAUTION:  
Burn Hazard  
4. Rotate elements back into place.  
OVEN RACK INSTALLATION  
1. Install fan baffle.  
Use care around the  
fan. The blades are  
sharp.  
2. Install one rack support  
on the fan baffle, and  
one rack support on the  
left wall of the oven  
cavity.  
DO NOT OPERATE UNLESS  
GREASE TROUGH  
IS INSTALLED.  
3. Install racks as needed  
for the product being  
prepared.  
Moisture will drip into the hot  
cooking surface, causing  
splattering of hot liquids.  
Serious injury can result from  
contact with hot splatter.  
Fig. 9 Oven Rack Installation  
12  
OPERATION  
CAUTION:  
VENTILATOR OPERATION  
Hot Surface  
1. Press the VENTILATOR POWER switch to ON. The green  
VENTILATOR POWER light will glow and the blower fan will start.  
After a short time, if all filters are sensed as being in position and  
not clogged, the cooking appliance will be energized.  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
During normal operation, the VENTILATOR POWER light will be  
the only light glowing on the upper control panel.  
2. If the amber CHECK FILTER light glows, one or more filter  
elements is out of position. Check the GREASE BAFFLE,  
PRE-FILTER and FILTER PACK for proper installation in their  
respective positions. Grease baffle and filter pack position are  
sensed by mechanical switches. Pre-filter position is sensed by a  
vacuum switch.  
3. When the amber REPLACE PRE-FILTER light glows, the pre-filter  
is nearing the end of its service life. Replace the disposable  
PRE-FILTER ELEMENT.  
4. When the amber REPLACE FILTER PACK light illuminates, the  
HEPA / Charcoal filter pack is nearing the end of its service life.  
Replace the FILTER PACK.  
Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK  
lights are a warning that the indicated filter is near the end of its  
service life. The appliance will continue to operate for a period of  
time after the light glows to allow continued operation through a  
peak period. However, the indicated filters must be replaced within  
a reasonably short time period or they will clog and shut down  
electrical power to the cooking appliance . The ventilator blower  
will continue to run.  
5. When the red SERVICE REQUIRED light glows, either the  
pre-filter or filter pack (or both) is clogged and can no longer pass  
sufficient air to allow further operation. The ventilator fan continues  
to run, but the cooking appliance is shut down until the underlying  
clogged filter situation has been corrected. This can occur when  
neither CHANGE...FILTER indicator light is lit, if both pre-filter and  
filter pack are marginal. Replacing both the pre-filter and the filter  
pack will remedy the situation.  
Note: Replacing the pre-filter, even though not very dirty, will often  
extend the service life of the more expensive filter pack.  
Reset the unit by turning the VENTILATOR POWER switch to  
OFF, then back ON.  
Fig. 10 Ventilator Indicator  
and Warning Lights  
6. A failure of incoming electrical power will cause a shut down of the  
unit. After power is restored, reset the unit by turning the  
VENTILATOR POWER switch to OFF, then back ON.  
NOTE: Oven, griddle and hotplate will not operate unless the fire  
suppression system is charged, and the ventilator section is operating .  
13  
OPERATION (continued)  
SUGGESTED COOKING TIMES  
A. CONVECTION OVEN  
PRODUCT  
TEMP  
TIME  
NUMBER  
ºF  
MINUTES  
OF RACKS  
BREAD PRODUCTS  
Hamburger Roll  
Bread (1 lb loaves)  
Roll  
300  
325  
300  
400  
15  
34  
16  
7
5
3 (12 loaves)  
5 (60 rolls)  
3
Baking Soda Biscuit  
For best baking results, use rack positions 2, 5 & 8 ( where rack position 1 is the top rack)  
Baking one pan: use rack 5; baking 2 pans: use racks 2 & 8.  
PASTRIES  
Sheet Cake (2½ lbs. per pan)  
300  
350  
350  
300  
350  
275  
300  
17  
50  
40  
15  
12  
75  
19  
5
Frozen Fruit Pie (46oz.)  
Frozen Fruit Pie (26oz. - 8" dia.)  
Sugar Cookie  
Danish Roll  
Fruit Cake  
5 (10 pies)  
5 (15 pies)  
5
5
3
Cake (1 lb.)  
5 (10 cakes)  
OTHER  
Melted Cheese Sandwich  
Idaho Potato (120 potatoes)  
Macaroni & Cheese  
400  
450  
350  
8
40  
30  
5
5
5
NOTE: "HIGH" fan speed provides the fastest cook time. "LOW" fan speed is used for foods which are  
sensitive to air currents, such as meringue pie.  
B. GRIDDLE  
PRODUCT  
TEMP  
ºF  
TIME  
MINUTES  
Sausage (Link or Patty)  
Bacon  
Canadian Bacon  
Ham Steak  
Minute Steak  
Hamburger  
Melted Cheese Sandwich  
Hot Dog  
French Toast  
350  
350  
350  
375  
400  
350  
375  
325  
350  
375  
300  
300  
300  
3-4  
2-3  
2-3  
3-4  
3-4  
3-4  
3-4  
2-3  
2-3  
2
Pancakes  
Eggs, Scrambled  
Eggs, Hard Fried  
Eggs, Sunny Side Up  
1-2  
3
2
14  
OPERATION (continued)  
CONVECTION OVEN OPERATING INSTRUCTIONS  
CAUTION:  
Hot Surface  
A. MANUAL COOK MODE  
1. Set the OVEN POWER SWITCH (C.01) to ON. The OVEN  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
POWER ON INDICATOR (C.03) will glow when the switch is ON.  
2. Rotate OVEN TEMPERATURE CONTROL knob (C.07) until the  
desired cooking temperature is displayed on the READOUT  
(C.05A). The oven will begin heating, and the temperature digits  
will flash, until the set temperature is reached.  
CAUTION:  
Electrical Shock  
3. Rotate OVEN TIME CONTROL knob (C.06) until the desired time  
is displayed on the READOUT. The digits and colon will flash,  
indicating that time has been set but the timer is not started.  
Hazard  
DO NOT splash or pour water  
onto control panel or wiring.  
4. Load product in the oven. Press START TIMER key (C.08). The  
timer digits count down and the colon (only) flashes during the  
timer period.  
CAUTION:  
Electrical Shock  
Hazard  
5. At the end of the timer period, an audible alarm will sound. Press  
CANCEL key (C.11) to silence the alarm.  
SUGGESTION: For best baking results when making baking soda  
biscuits, use rack positions 2, 5 & 8 ( where rack position 1 is the top  
rack). When baking one pan: use rack 5 (center rack); when baking  
2 pans: use racks 2 & 8; when baking three pans: use racks 2, 5 & 8.  
DO NOT operate the unit if  
the keypad is torn or broken.  
B. PROGRAM COOK MODE  
C.04  
C.02  
C.03  
C.01  
1. Five (5) programmable keys (C.10) are provided for presetting  
frequently used time / temperature combinations. To set the  
program:  
a. Press and hold the appropriate PGM key.  
b. While holding the PGM key, turn the TIME and TEMP knobs  
until the desired time and temperature is displayed on the  
readout.  
c. Release the PGM key to store the displayed time and temp in  
memory.  
C.05  
A
C.05  
C.06  
C.05  
B
2. The program for any PGM key can be recalled by momentarily  
pressing that PGM key.  
C.07  
3. To start a programmed cook cycle, press the appropriate  
PGM key and the START TIME key. Once the cook cycle  
has started, the TIME and TEMP knobs are locked out to  
prevent accidental re-programming.  
C.08  
C.10  
C.09  
C.11  
4. The actual oven temperature may be recalled at any time  
by pressing the ACTUAL TEMP key (C.09).  
5. At the end of the timer period, an audible alarm will sound.  
Press CANCEL key (C.11) to silence the alarm.  
15  
OPERATION (continued)  
C. TEMPERATURE OFFSET MODE  
CAUTION:  
Hot Surface  
1. A user preference offset mode is provided should the user feel the  
oven cooks too hot or too cold.  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
2. The OFFSET MODE can be used to offset the set / displayed  
temperature from the sensed temperature by as much as ± 35ºF, in  
5ºF increments:  
a. Rotate the TIME controller until the time digits on the display  
read "00:00".  
b. Rotate the TEMP control until the temp digits display between  
400º and 500º.  
c. Press and hold the START TIMER key for five seconds.  
d. Turn either the TIME or TEMP control until the desired offset is  
displayed.  
CAUTION:  
Burn Hazard  
Do not attempt to clean the  
oven until it has cooled to  
150ºF or less. See  
e. Press the ACTUAL TEMP key to exit.  
CLEANING INSTRUCTIONS,  
page 18  
GRIDDLE OPERATING INSTRUCTIONS  
A. SEASONING  
CAUTION:  
Electrical Shock  
Hazard  
DO NOT splash or pour water  
onto control panel or wiring.  
The metal surface of the griddle has microscopic pores. It is important  
to fill the pores with cooking oil to provide a hard, non-stick cooking sur-  
face.  
1. Turn GRIDDLE TEMPERATURE CONTROL (G.01) clockwise to  
375ºF. Allow the griddle to heat until the GRIDDLE HEAT ON IN-  
DICATOR (G.02) goes OFF, showing that the griddle is up to the  
set  
temperature.  
2. Spread a light film of oil over the entire griddle surface.  
3. Allow the oil film to "cook in" for 2 - 3 minutes, or until the oil  
smokes.  
4. Wipe the griddle surface with a clean cloth to remove any standing  
oil.  
5. For new griddles, repeat this procedure 2 - 3 times, until the griddle  
has a slick, clean surface.  
IMPORTANT:  
To extend the life of your  
appliance and internal  
components, allow the oven,  
griddle and hotplates cool to  
200ºF or less before turning  
the ventilator off.  
B. COOKING WITH YOUR GRIDDLE  
1. Turn the GRIDDLE TEMPERATURE CONTROL (G.01) to the de-  
sired cooking temperature. The solid-state thermostatic  
will automatically maintain set temperature.  
controller  
2. The GRIDDLE HEAT ON INDICATOR (G.02) will glow when the  
heating elements are energized.  
16  
OPERATION (continued)  
CAUTION:  
HOTPLATE OPERATING INSTRUCTIONS  
Hot Surface  
A. COOKING WITH YOUR HOTPLATE  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
1. Each element is individually controlled by a TEMPERATURE  
CONTROL (H.01 and H.03). These are infinite switch controls  
which control based on electrical current draw, not the actual  
temperature of the hotplate surface.  
CAUTION:  
Electrical Shock  
Hazard  
2. Settings are OFF to  
HIGH.  
DO NOT splash or pour water  
onto control panel or wiring.  
3. The associated  
indicator will glow  
when the switch is in  
any position other  
than OFF.  
CAUTION:  
Electrical Shock  
Hazard  
4. When set to HIGH, the  
hotplate element can  
reach maximum  
temperature in  
Use extreme caution when  
using double broiler-type  
pans: DO NOT over fill the  
lower pan with water, which  
can cause an overflow. Any  
moisture splashed onto the  
hotplate top can leak into the  
lower areas of the oven  
causing a potential shock  
hazard and causing severe  
damage to the electronic  
controller.  
approximately 10  
minutes.  
5. Once liquid begins to boil, reduce the setting to minimize power  
consumption and increase the useful life of the elements.  
6. Use cooking pans which fully cover the elements for maximum  
efficiency. Maximum recommended pot diameter is 10 inches.  
NOTE: Damage caused by  
moisture leaking into the  
electronic controller is NOT  
covered by warranty.  
IMPORTANT:  
The dial markings are an  
INDICATION of temperature  
only. The temperature of the  
food product depends on  
many factors, including the  
size, shape and material of  
the food container, and the  
quantity and consistency of  
the food product.  
17  
CLEANING INSTRUCTIONS  
CONVECTION OVEN CLEANING INSTRUCTIONS  
DANGER  
ELECTRIC SHOCK HAZARD  
PRECAUTIONS  
Turn oven power switch to FAN  
Allow oven to cool  
FREQUENCY  
TOOLS  
As Noted  
Mild Detergent, Soft Cloth or Sponge  
Plastic Scouring Pad  
Spray Bottle  
Commercial Oven Cleaner/Degreaser  
DAILY  
1. Ventilator fan must be ON. Turn oven power switch to FAN; remove  
racks and take to sink.  
DO NOT SPRAY WATER ON OR AROUND  
ELECTRICAL EQUIPMENT  
DO NOT WASH FLOOR NEAR ELECTRICAL  
EQUIPMENT WITH WATER SPRAY  
2. Let oven cool to 200°F. If oven is cooler than 200°F, raise  
temperature to no more than 200°F.  
3. Mix oven cleaner/degreaser per manufacturer’s directions. Spray  
oven cleaner/degreaser solution onto soiled surfaces; then, close  
oven door and let stand for 5 min.  
CAUTION:  
Cut Hazard  
4. Open door slowly to allow steam to escape and allow oven to cool  
completely.  
Use due care when cleaning  
near fan. Blades are sharp.  
5. Wipe oven surfaces with a soft cloth, rinse cloth as necessary.  
6. Re-spray any remaining soiled areas and scrub with a plastic  
scouring pad.  
CAUTION:  
Electrical Shock  
Hazard  
7. Rinse all surfaces with a clean soft cloth dampened with clean  
water.  
DO NOT splash or pour water  
onto control panel or wiring.  
8. Wash, rinse, and sanitize oven racks and replace in oven.  
9. Wipe exterior surfaces with a clean cloth dampened with clean  
water and a non-abrasive cleanser. Rinse by wiping with a clean  
cloth dampened with clean water.  
CAUTION:  
Heat and Smoke  
Hazard  
Keep the ventilator fan  
running during any "hot  
surface" cleaning operation to  
avoid a build-up of heat and/  
or smoke.  
HEAVY SOIL RECOVERY—As Needed  
1. Turn oven power switch to FAN; remove racks and take to back  
sink.  
2. Let oven cool to 200°F. If oven is cooler than 200°F, raise  
temperature to no more that 200°F.  
IMPORTANT: Avoid Fire  
Suppression System  
discharge!  
3. Spray Oven Cleaner/Degreaser full strength onto soiled surfaces;  
then, close oven door and let stand for 5 min.  
Keep the ventilator fan  
running during any "hot  
surface" cleaning operation to  
avoid melting a fusible link  
and causing a discharge of  
the fire suppression media.  
4. Open door slowly to allow steam to escape and allow oven to cool  
completely.  
5. Wipe oven surfaces with a soft cloth, rinse cloth as necessary.  
6. Re-spray any remaining soiled areas and scrub with a plastic  
scouring pad.  
IMPORTANT:  
7. Rinse all surfaces with a clean soft cloth dampened with clean  
water.  
Always rub / wipe in the  
direction of the polish lines  
or grain of the metal.  
8. Wash, rinse, and sanitize oven racks and replace in oven.  
18  
CLEANING INSTRUCTIONS (continued)  
GRIDDLE CLEANING INSTRUCTIONS  
CAUTION:  
Hot Surface  
PRECAUTIONS  
Griddle surfaces are HOT. Wear appropriate heat  
protective gloves, apron and goggles  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
FREQUENCY  
TOOLS  
As Noted  
Scraper, Pumice Stone or Griddle Brick  
Clean Cooking Oil  
CAUTION:  
Electrical Shock  
Hazard  
Mild Detergent, Soft Cloth or Sponge  
Plastic Scouring Pad  
DO NOT splash or  
pour water onto  
control panel or wiring.  
1. To keep the griddle clean and food flavors at their best, scrape the  
griddle after preparing each order. Scrape excess food into the  
waste hole in the grease trough (front of the griddle cooking  
surface). After each 2 - 3 orders, wipe the griddle surface with a  
light coat of oil.  
CAUTION:  
Heat and Smoke  
Hazard  
2. Clean the griddle surface daily, at a minimum:  
a. Keep the ventilator fan ON.  
Keep the ventilator fan  
running during any "hot  
surface" cleaning operation to  
avoid a build-up of heat and/  
or smoke.  
b. Set griddle temperature control to 220ºF. Allow the griddle  
temperature to drop to 220ºF before proceeding.  
c. Pour a small amount of water on the griddle surface and let it  
"sizzle".  
d. Use a pumice stone or griddle brick to remove all remaining  
waste, and to clean the griddle surface down to bright metal.  
Wipe off any remaining powder residue.  
e. Use a soft-bristled fiber brush in a circular motion to remove any  
remaining food particles.  
f. Turn temperature control to OFF. Allow the griddle surface to  
cool, then wipe the surface with a clean cloth.  
g. Dry the griddle surface thoroughly.  
IMPORTANT: Avoid Fire  
Suppression System  
discharge!  
Keep the ventilator fan  
running during any "hot  
surface" cleaning operation to  
avoid melting a fusible link  
and causing a discharge of  
the fire suppression media.  
h. Season the cooking surface after each cleaning using the  
instructions on page 10.  
3. At least once each day, the GREASE TROUGH must be  
thoroughly cleaned. Using a scraper, remove all grease and  
food waste from the grease trough and into the grease drawer.  
IMPORTANT:  
This appliance is not jet  
stream approved. Do not  
direct water jet or steam jet  
at this appliance, or at any  
control panel or wiring.  
Do not splash or pour  
water on, in or over any  
controls, control panel or  
wiring.  
4. After scraping all cooking waste from grease trough into GREASE  
DRAWER, take the grease drawer to kitchen cleaning area and  
properly dispose of all waste.  
a. Clean drawer with hot water and a mild detergent.  
b. Dry drawer thoroughly and reinstall in griddle.  
5. GRIDDLE EXTERIOR:  
a. Wipe down splash guards, griddle body and the grease trough  
with a cloth dampened with warm water and a mild detergent.  
b. A plastic scouring pad and a non-abrasive cleanser may be  
used for hard-to-remove food particles.  
c. Rinse thoroughly with clean water. DO NOT splash or pour  
water onto control panel or wiring.  
d. Dry griddle with a soft, clean cloth.  
19  
CLEANING INSTRUCTIONS (continued)  
HOTPLATE CLEANING INSTRUCTIONS  
CAUTION:  
Burn Hazard  
PRECAUTIONS  
Turn oven controls to OFF  
Turn off both hotplates and  
allow to cool before cleaning  
Allow hotplates to cool  
FREQUENCY  
TOOLS  
Daily  
Mild Detergent, Soft Cloth or Sponge  
CAUTION:  
Heat and Smoke  
Hazard  
Non-abrasive Cleaner, Plastic Scouring Pad  
Keep the ventilator fan  
running during any "hot  
surface" cleaning operation to  
avoid a build-up of heat and/  
or smoke.  
1. Turn both controls to OFF. Allow both hotplate elements to cool.  
2. Wipe the entire hotplate top panel using a clean cloth or sponge,  
dampened with hot water and a mild detergent. For burned-on  
foods or sauce spillage, use a non-abrasive cleanser applied with  
a plastic scouring pad.  
IMPORTANT: Avoid Fire  
Suppression System  
discharge!  
Allow hotplates to cool to  
200ºF or less before turning  
the ventilator off to avoid  
melting a fusible link and  
causing a discharge of the  
fire suppression media.  
3. Rinse hotplates and top panel with a soft cloth dampened with clean  
water.  
IMPORTANT:  
This appliance is not jet  
stream approved. Do not  
direct water jet or steam jet  
at this appliance, or at any  
control panel or wiring.  
Do not splash or pour  
water on, in or over any  
controls, control panel or  
wiring.  
IMPORTANT:  
Always wipe or rub in the  
direction of the polish lines  
or grain of the metal.  
20  
CLEANING INSTRUCTIONS (continued)  
VENTILATOR SECTION CLEANING INSTRUCTIONS  
CAUTION:  
Electric Shock  
Hazard  
PREPARATION  
Disconnect appliance from electric power  
Allow to cool before cleaning  
Disconnect appliance from  
electric power before  
cleaning.  
FREQUENCY Weekly  
CAUTION:  
TOOLS  
Hot Surface  
Warm water and a mild detergent  
Soft clean cloth or sponge  
Bristle brush  
Exposed surfaces  
can be hot to the touch  
and may cause burns. Allow  
appliance to cool before  
cleaning.  
Container for disposal of grease  
CLEANING  
Disconnect appliance from electric power  
Allow to cool before cleaning  
IMPORTANT:  
Never allow PRE-FILTER or  
FILTER PACK to get wet.  
DO NOT wash either of these  
two filters. Washing these  
filters will ruin them and cause  
the appliance to shut-down.  
Remove the grease baffle, pre-filter assembly, grease trough and  
grease cup. Empty the grease trough and grease cup.  
Remove the pre-filter from the filter frame. Wash and rinse the  
filter frame ONLY.  
Wash and rinse the grease baffle, grease trough and grease cup in  
a sink or dishwasher using mild detergent and warm water. Allow  
to air dry.  
IMPORTANT:  
DO NOT spill or pour water  
into controls, control panel,  
wiring or coil-type hotplate  
elements. Damage to internal  
components will occur.  
Damage to internal  
Reinsert the pre-filter into the filter frame. Reinstall the pre-filter,  
grease baffle, grease trough and grease cup.  
Procedure is complete  
components from water  
damage is not covered by  
warranty.  
IMPORTANT:  
This appliance is not jet  
stream approved. Do not  
direct water jet or steam jet  
at this appliance, or at any  
control panel or wiring.  
Do not splash or pour  
water on, in or over any  
controls, control panel or  
wiring.  
IMPORTANT:  
DO NOT use steel wool or  
metal implements to clean  
drawers or cabinet surfaces.  
21  
TROUBLESHOOTING SUGGESTIONS  
A. NO PART OF THE APPLIANCE WILL HEAT  
CAUTION:  
Electrical Shock  
Hazard  
Removal of any cabinet panel  
will result in exposed  
1. Verify that appropriate cooking controls are ON.  
2. Check electrical supply. Make sure service breaker is ON.  
3. Make sure all filters are properly installed, and that no filter warning  
lights are lit.  
4. Possible improper service wiring: Have a licensed electrician verify  
that all three legs of the 3ø service are properly connected  
(i.e. Leg 1 to L1, Leg 2 to L2, Leg 3 to L3), and that all three legs are  
of the proper voltage and phase.  
electrical circuits. Any  
procedure requiring the  
removal of any cabinet panel  
must be performed by a  
qualified technician only.  
5. Ansul® fire suppression system not charged.  
B. GRIDDLE WILL NOT HEAT  
1. Verify that temperature control is set to the desired temperature.  
2. Possible internal component damage: Have unit serviced by an  
Authorized Wells Service Agency.  
CONVECTION OVEN  
CONTROLLER  
ERROR CODES  
C. HOTPLATE WILL NOT HEAT  
F1 Relay closed or relay  
ohms low when not  
cooking  
1. Verify that associated temperature control is set to the desired  
temperature.  
2. Possible internal component damage: Have unit serviced by an  
Authorized Wells Service Agency.  
F2 Actual temperature 60ºF  
(±35ºF) greater than  
T-SET MAX  
DCONVECTION OVEN WILL NOT HEAT  
See Error Codes diagram at right  
F3 Open temperature sensor  
1. Verify that the oven switch is ON and that the temperature control is  
set to the desired temperature.  
2. Verify that the door is closed.  
3. Hi-Limit control may have tripped: Allow unit to cool; Hi-Limit will  
reset automatically.  
4. Blown fuse(s) (item 40): Correct cause of over-current and replace  
fuses with fuses having the same configuration and ratings.  
5. Possible internal component damage: Have unit serviced by an  
Authorized Wells Service Agency.  
F4 Shorted temperature  
sensor  
F5 Relay open or relay ohms  
high when cooking  
F6 No 60 Hz (Cycles per  
second other than 60 Hz  
detected)  
E. CONVECTION OVEN FAN WILL NOT RUN  
1. Verify that the oven switch is set to ON or FAN.  
2. Verify that the fan switch is set to either HIGH or LOW.  
3. Hi-Limit control may have tripped: Allow unit to cool; Hi-Limit will  
reset automatically.  
Have unit serviced by an  
Authorized Wells Service  
Agency.  
4. Blown fuse(s): Correct cause of over-current and replace fuses with  
fuses having the same configuration and ratings.  
5. Possible internal component damage: Have unit serviced by an  
Authorized Wells Service Agency.  
NOTE: There are no user  
serviceable components in  
the appliance. In all cases of  
damage or component  
malfunction, contact your  
Authorized Wells Service  
Agency for repairs.  
22  
MAINTENANCE INSTRUCTIONS  
A. FAN CLEANING  
CAUTION:  
Personal Injury  
Hazard  
1. Disconnect power at the circuit breaker. Allow the oven to cool.  
2. Remove RACKS by pulling toward the front. Lift to clear the stop  
pin. Remove left and right RACK SUPPORTS by lifting.  
Disconnect appliance from  
electrical power before  
performing any of these  
procedures  
3. Remove BAFFLE by  
lifting the rear slightly  
and pulling straight  
out.  
4. Brush fan wheel and  
wipe it with a moist  
cloth. Sponge out all  
loose particles.  
CAUTION:  
Cut Hazard  
Use due care when  
cleaning fan. Blades are  
sharp.  
5. Reassemble, paying  
particular attention  
that the lip on the right  
side of the fan baffle is  
fully seated in the slot  
in the edge of the  
oven cavity.  
B. LATCH ADJUSTMENT  
1. The door latch must be adjusted such that the door will latch easily,  
yet remain closed and latched throughout the cook cycle.  
If the door is too tight when the oven is cold, it may pop open as  
the oven reaches temperature.  
2. Check adjustment in two places on the latch-side of the door.  
Use a piece of paper (such as a dollar bill) between the inner  
surface of the door and the door gasket, just above and just below  
the latch. The paper should be definitely held, but should be able to  
be pulled out with just a slight drag.  
LATCH  
3. To adjust the vertical alignment, hold the striker assembly while  
loosening the two screws. Move the striker assembly as needed,  
but do not allow the parts of the striker to move in relation to each  
other. Retighten the screws and re-check the alignment.  
BACK PLATE  
STRIKER  
FRONT PLATE  
4. To adjust the fore-and-aft alignment, the back plate acts as a  
tapered shim. Moving the back plate vertically, in relation to the  
striker, will adjust the thickness of the striker assembly. When  
properly adjusted for thickness, verify the vertical alignment and  
tighten the screws.  
5. Recheck the alignment. Recheck the tightness of the screw.  
23  
MAINTENANCE INSTRUCTIONS (continued)  
C. HINGE ADJUSTMENT  
1. The hinges provide the pivot for the door, allow for height  
adjustment and alignment so that the door closes properly on  
the gasket.  
2. To access the hinge adjustments:  
a. Remove the grease tray. Remove the upper trim panel  
by removing the four screws at the ends of the panel.  
The trim panel / grease tray support assembly will then  
pull straight out.  
b. Remove the bottom trim panel by removing the four  
screws at the ends of the panel, and by loosening the  
two screws holding the bottom door gasket. The panel  
will then pull straight out.  
3. The door should be approximately centered between the upper  
and lower lips of the cabinet. Adjust the door for height:  
a. The hinge sleeve acts as a jam nut for the height  
adjuster.  
b. The top and bottom clearances should be approximately  
equal. If necessary, loosen the hinge sleeve and turn  
the height adjustment nut until the required clearances  
are achieved.  
TOP  
PANEL  
c. Retighten the hinge sleeve.  
4. Check fore-and-aft adjustment in two places on the hinge-side  
of the door. Use a piece of paper (such as a dollar bill) between  
the inner surface of the door and the door gasket. The paper  
should be definitely held, but should be able to be pulled out  
with just a slight drag.  
5. To adjust a top or bottom hinge:  
a. Loosen the holding bolts.  
b. Tighten or loosen the adjusting bolt as needed to achieve  
the proper vertical clearances.  
c. Retighten the holding bolts.  
BOTTOM  
PANEL  
d. Recheck the clearances. Recheck the tightness of the  
bolts.  
6. Reassemble the trim panels. Remember to retighten the screws  
for the lower gasket  
HINGE SLEEVE  
HINGE BRACKET  
HINGE BRACKET  
HOLDING  
BOLTS  
HOLDING  
BOLTS  
DOOR PIVOT  
HEIGHT  
ADJUSTMENT  
ADJUSTING  
BOLT  
ADJUSTING  
BOLT  
24  
MAINTENANCE INSTRUCTIONS (continued)  
D. TEMPERATURE CALIBRATION  
CAUTION:  
Hot Surface  
TOOLS:  
Digital Pyrometer with Oven Probe, Protective Gloves  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
1. With the oven empty, clamp the thermocouple sensor in the center  
of the middle rack:  
a. Pass the thermocouple sensor wires through the corner of the  
door gasket and close the door.  
b. Plug the sensor into the Pyrometer.  
2. Turn the OVEN POWER (V.01) switch to ON. Turn the FAN  
switch (V.02) to HI.  
a. Rotate the TIME control (V.06) until the time digits (V.05B) on  
the display read "60:00".  
b. Rotate the TEMP control (V.07) until the temp digits (V.05A)  
display 375º.  
c. Press the START TIMER key (V.08).  
3. Allow the oven to heat for 45 minutes. If, after 45 minutes, the  
temperature display reads between 370º and 380º, the calibration  
is satisfactory. Otherwise:  
a. Rotate the TIME controller until the time digits (V.05B) on the  
display read "00:00".  
b. Rotate the TEMP control until the temp digits (V.05A) display  
between 400º and 500º.  
c. Press and hold the START TIMER (V.08) key for five seconds.  
d. Turn either the TIME or TEMP control until the desired offset is  
displayed.  
e. Press the ACTUAL TEMP (V.09) key to exit. Procedure is  
complete.  
25  
ANSUL INCORPORATED  
MARINETTE, WI 54143-2542  
MATERIAL SAFETY DATA SHEET  
®
ANSUL  
ANSULEX Low pH  
QUICK IDENTIFIER (In Plant Common Name)  
Emergency  
Telephone No.:  
Manufacturer’s  
Name:  
CHEMTREC  
ANSUL INCORPORATED  
(800) 424-9300 or (703) 527-3887  
Other Information  
Calls:  
Address:  
One Stanton Street, Marinette, WI 54143-2542  
(715) 735-7411  
Date Prepared:  
Prepared By:  
Safety and Health Department  
February 1, 1999  
SECTION 1 - IDENTITY  
Common Name (Used on Label):  
(Trade Name and Synonyms)  
CAS No.:  
ANSULEX Low pH Liquid Fire Suppressant  
N/A  
Chemical  
Name:  
Chemical  
Family:  
Mixture  
N/A This is a Mixture  
N/A  
Formula:  
SECTION 2 - INGREDIENTS  
PART  
A
-
HAZARDOUS INGREDIENTS  
Principal Hazardous Component(s) (chemical and common name(s)):  
Acute Toxicity Data  
Wt.%  
CAS No.  
ACGIH TLV  
None  
N/A  
N/A  
N/A  
N/A  
PART  
B
-
OTHER INGREDIENTS  
Acute Toxicity Data  
Other Component(s) (chemical and common name(s)):  
Wt.%  
CAS No.  
ACGIH TLV  
Proprietary Mixture of Organic and Inorganic Salts  
N/A  
N/E  
NDA  
48.0 - 50.0  
0.2  
Phosphoric Acid  
EDTA  
N/E  
N/E  
NDA  
NDA  
7664-38-2  
64--02-8  
518-47-8  
0.65  
Oral LD50(rat)  
6800 mg/kg  
Yellow-Green Fluorescent Dye  
Water  
0.011  
N/E  
N/E  
Approx. 50.0  
NDA  
7732-18-5  
SECTION 3 - PHYSICAL AND CHEMICAL CHARACTERISTICS (Fire and Explosion Data)  
Vapor Pressure  
(mm Hg):  
Boiling  
Point:  
Specific  
Gravity (H2O=1):  
Not Determined  
113ºC  
1.33  
Percent Volatile  
by Volume (%):  
Vapor Density:  
(Air = 1):  
Evaporation Rate: Approx. 0.005  
Approx. 50.0  
1.03  
(Butyl Acetate=1):  
Reactivity in  
Water:  
Solubility  
in Water:  
Mild exothermic reaction  
100%  
Appearance  
and Odor:  
Fluorescent Yellow Colored Liquid, Mild Odor  
Extinguisher  
Media:  
Auto-Ignition  
Temperature:  
Flammable Limits  
in Air % by Volume:  
Flash Point:  
None to boiling  
N/A  
N/A  
N/A  
Special Fire  
Fighting Procedures: NONE - THIS IS AN EXTINGUISHING AGENT  
Unusual Fire and  
Explosion Hazards:  
None  
SECTION 4 - PHYSICAL HAZARDS  
Conditions  
to Avoid:  
Unstable  
Stable  
Stability:  
N/A  
Incompatibility  
(Materials to Avoid):  
Reactive Metals, ClF3, electrically energized equipment, any material reactive with water.  
Hazardous  
Decomposition Products:  
Not established, acrid fumes.  
Hazardous  
Polymerization:  
May Occur  
Will Not Occur  
Conditions  
to Avoid:  
N/A  
26  
ANSULEX Low pH (continued)  
SECTION 5 - HEALTH HAZARDS  
Threshold  
Limit Value:  
None Established  
Routes of Entry:  
Eye Contact:  
Irritant  
Skin Contact:  
Inhalation:  
Irritant  
Not an expected route of entry. Can be irritating to mucous membranes.  
Ingestion:  
Irritating to mucous membranes. Acute Oral LD50 (Sprague-Dawley rats) 825.5mg/kg.  
Signs and  
Symptoms:  
Acute Exposure: Material irritates skin, eyes, and mucous membranes.  
Chronic Exposure: None known.  
Medical Conditions Generally  
Aggravated by Exposure:  
None known.  
OSHA  
Yes  
No  
Yes  
No  
Chemical Listed as  
Carcinogen or Potential:  
I.A.R.C  
Monographs:  
Yes  
No  
National Toxicology  
Program:  
SECTION 6 - EMERGENCY AND FIRST AID PROCEDURES  
Flush and irrigate with water for 15 minutes while holding eyelids open.  
If irritation persists, seek medical attention.  
Eye Contact:  
Skin Contact:  
Inhalation:  
Wash thoroughly with soap and water. If irritation persists, seek medical attention.  
Fresh air if symptoms occur. If irritation persists, seek medical attention.  
Dilute by drinking large quantities of water.  
Ingestion:  
SECTION 7 - SPECIAL PROTECTION INFORMATION  
Respiratory Protection  
N/A  
(Specify Type):  
Ventilation:  
Mechanical  
(General):  
Local  
Exhaust:  
N/A  
N/A  
Chemical goggles recommended during  
spill/leak procedures.  
Eye  
Protection:  
Protective  
Gloves:  
Rubber gloves for spill/leak  
Other Protective  
Clothing or Equipment:  
Eye wash and safety showers are good safety practice.  
SECTION 8 - SPECIAL PRECAUTIONS AND SPILL/LEAK PROCEDURES  
Precautions to be taken  
in Handling and Storage:  
Store in original container. Keep tightly closed. Keep separate from acid.  
See incompatibility information in Section 4.  
Other  
Precautions:  
Steps to be taken in Case  
Material is Released or Spilled:  
Stop leaks. Contain spills. Remove as much as possible. Place in closed container for proper disposal  
Wash spill area with large amounts of water to remove traces and neutralize.  
Waste Disposal  
Methods:  
Dispose of in compliance with local, state and federal regulations.  
HAZARDOUS MATERIAL IDENTIFICATION SYSTEM  
HAZARD INDEX  
4
3
2
1
0
SEVERE HAZARD  
SERIOUS HAZARD  
MODERATE HAZARD  
SLIGHT HAZARD  
0
HEALTH  
0
FLAMMABILITY  
REACTIVITY  
MINIMAL HAZARD  
0
N/A = Not Applicable  
NDA = No Data Available  
N/E = Not Established  
ANSUL and ANSULEX are registered trademarks.  
Internet Address: http://www.ansul.com  
ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542  
Form No. F-90160-6  
©1999 Ansul Incorporated  
27  
28  
29  
MAINTENANCE SCHEDULES  
USE AND MAINTENANCE  
SHALL BE IN ACCORDANCE  
WITH THE STANDARD FOR  
VENTILATION CONTROL  
AND FIRE PROTECTION OF  
COMMERCIAL COOKING  
OPERATIONS, N.F.P.A 17A  
& N.F.P.A. 96 (current  
1. 6-MONTH MAINTENANCE (MUST BE PERFORMED BY AN  
AUTHORIZED ANSUL® DISTRIBUTOR ONLY):  
a. Inspect and test total operation including FIRE DAMPER and  
all SAFETY INTERLOCKS.  
b. All FIRE SUPPRESSION SYSTEM actuation components  
including MANUAL PULL STATION and any REMOTE  
MANUAL PULL STATION must be inspected for proper  
operation in accordance with the maintenance schedule  
published in ANSUL® R-102 SYSTEM DESIGN,  
INSTALLATION, RECHARGE AND MAINTENANCE MANUAL  
(Ansul® #418087-05).  
editions).  
DANGER  
Fire Hazard  
FAILURE TO PROPERLY  
CLEAN AND MAINTAIN THIS  
EQUIPMENT CAN  
c. The FIRE SUPPRESSION SYSTEM FUSIBLE LINKS must be  
inspected. NOZZLES and MANUAL PULL STATION must be  
cleaned in accordance with ANSUL® R-102 SYSTEM  
DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE  
MANUAL (Ansul® #418087-05).  
CAUSE A FIRE. AN  
UNCONTROLLED FIRE CAN  
CAUSE SERIOUS INJURY,  
DEATH AND/OR PROPERTY  
LOSS.  
d. The FIRE SUPPRESSION AGENT TANK, PIPING and  
FLEXIBLE TUBING must be INSPECTED.  
2. 12-YEAR MAINTENANCE: (MUST BE PERFORMED BY AN  
NOTE: A signed and dated  
VENTILATOR HOOD  
AUTHORIZED ANSUL® DISTRIBUTOR ONLY):  
MAINTENANCE LOG must  
be maintained on the  
premises, and shall be  
available for inspection by the  
authority having jurisdiction.  
See pages 28 & 29.  
a. The FIRE SUPPRESSION AGENT TANK and ¼” FLEX HOSE  
must be HYDROSTATICALLY TESTED, and the FIRE  
EXTINGUISHING AGENT must be REPLACED in accordance  
with the maintenance schedule published in ANSUL® R-102  
SYSTEM (STANDARD UL 300 LISTED).  
b. The FUSIBLE LINKS in plenum and damper must be  
REPLACED. This maintenance to be performed by qualified  
Ansul® service personnel only.  
IMPORTANT: Parts used  
for the Ansul® fire  
suppression system are not  
serviceable by the owner /  
operator. Procedures for  
servicing fire suppression  
equipment are described in:  
ANSUL® R-102 SYSTEM  
DESIGN, INSTALLATION,  
RECHARGE AND  
MAINTENANCE MANUAL  
(Ansul® #418087-05).  
30  
PARTS & SERVICE  
DESCRIPTION  
SERVICE  
IMPORTANT: Use only  
factory authorized service  
parts and replacement  
PART NO.  
OVEN RACK Replacement  
PRE-FILTER  
PRE-FILTER CAGE  
FILTER PACK (HEPA + CHARCOAL)  
GREASE BAFFLE  
GREASE CUP  
LEG KIT  
CASTER KIT  
DRIP TRAY, 8” (Spiral Hotplate)  
SCRAPER, CLEANING (Ceramic Hotplate)  
ELEMENT SUPPORT (Spiral Hotplate)  
CLEANING CREME, CERAMIC HOTPLATE  
21376  
22618  
22683  
22619  
22684  
22626  
22829  
22830  
21705  
filters  
.
For factory authorized  
service, or to order factory  
authorized replacement  
parts, contact your Wells  
authorized service agency,  
or call:  
22445  
500039  
501124  
Wells Manufacturing Co  
.
2 Erik Circle  
P. O. Box 280  
Verdi, NV 89439  
phone: (775) 345-0444  
WELLS BULLETIN (ANSUL® PARTS LIST)  
NOTE: Ansul® Manual 418087-05 and  
Wells Bulletin 303331 are intended for use  
303331  
by authorized Ansul® service personnel only.  
Ansul® Manual 418087-05 must be obtained  
through your authorized Ansul® distributor.  
fax:  
(888) 492-2783  
(Service Parts Dept.)  
Service Parts Department  
can supply you with the  
name and telephone  
number of the WELLS  
AUTHORIZED SERVICE  
AGENCY nearest you.  
CUSTOMER SERVICE DATA  
please have this information available if calling for service  
RESTAURANT _____________________________ LOCATION _____________  
INSTALLATION DATE ________________________ TECHNICIAN ___________  
SERVICE COMPANY ________________________________________________  
ADDRESS ___________________________ STATE ______ ZIP__________  
TELEPHONE NUMBER (_____)_____-_________  
EQUIPMENT MODEL NO. _______________  
EQUIPMENT SERIAL NO. _______________  
VOLTAGE: (check one)  
208  
240  
31  

HP Hewlett Packard HP Essential P221 21 5 C9E49A8#ABA User Manual
Fujitsu M5000 CL11 12 PI01 User Manual
Dacor EG486 and ER48D User Manual
Compaq SmartCore Express SMA200 User Manual
Cisco Systems UC5208U2BRIK9 User Manual
Bosch Appliances NCT 685 B User Manual
Black Box Computer Hardware ACS251A R2 User Manual
Asus P8H61 M LX R2 0 User Manual
Asus K8V User Manual
3Com 3101 BASIC User Manual