Transition Networks DVP 5960 User Manual

MEDIA CONVERTER TECHNICAL SPECIFICATIONS  
Host Connection  
IBM® S/3x (System 34, 36, 38) host, AS/400™  
host or 5x94 remote controller  
Minneapolis, MN 55344 USA  
5250 Copper/Fiber Media Converter  
Case dimensions  
Shipping Weight  
Environment  
4.75" x 3.0" x 1.0"  
(119mm x 76mm x 25mm)  
PS-CF-01, PS-CF-01(SC), PS-CF-01(SM)  
2 pounds  
(0.9 kilograms)  
Temperature:  
Humidity  
Altitude  
0-50°C (32-122°F)  
10-90%, non condensing  
0-10,000 feet  
USER’S GUIDE  
The TRANSITION Networks 5250 Copper to Fiber PS-CF-01 series media  
Warranty  
Five years  
®
converters, designed to support all IBM 5250 compliant devices (including  
devices operating at a non-standard rates), extends the signal distance of an  
AS/400™ or S/3x host computer or a 5x94 remote controller to terminal  
equipment over twisted-pair copper and over multimode or singlemode fiber.  
Power Supply Requirements Replace power supply with only the equivalent  
input rating (see below) and output rating (regulated 9VDC at 0.5 A).  
TN PN  
3525  
3525  
3518  
3514  
3525  
Requirement  
Location  
United Kingdom  
Europe  
USA/Canada/Mexico  
Japan  
Australia  
240 volts, 50 hertz  
230 volts, 50 hertz  
120 volts, 60 hertz  
100 volts, 50-60 hertz  
240 volts, 50 hertz  
PS-CF-01 series media converters allow twisted-pair copper network  
extension distances up to 1524 meters (762 meters each connection on  
two media converters) AND fiber network extension distances up to 2  
kilometers on multimode fiber and up to 8 kilometers on singlemode  
fiber.*  
NOTE: This product also can be powered by the Transition Networks E-MCR series media  
converter rack.  
PS-CF-01  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Provides an RJ-45 twisted-pair  
connector to copper cable and a  
set of RX (receive) and TX  
(transmit) ST connectors to  
multimode fiber-optic cable.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten  
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur  
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen  
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.  
Compliance Information  
UL Listed  
C-UL Listed (Canada)  
CISPR/EN55022 Class A  
PS-CF-01(SM)  
PS-CF-01(SC)  
Provides an RJ-45 twisted-pair  
connector to copper cable and an  
RX (receive) ST and TX (transmit)  
SC connector to singlemode fiber-  
optic cable.  
Provides an RJ-45 twisted-pair  
connector to copper cable and an  
RX (receive) and TX (transmit) SC  
connector to multimode fiber-optic  
cable.  
FCC Regulations  
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant  
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial environment. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference, in which case the user will be  
required to correct the interference at the user’s own expense.  
STATUS LEDS  
Canadian Regulations  
Power  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on  
the radio interference regulations of the Canadian Department of Communications.  
TX  
RX  
Power  
Steady green LED  
indicates connection  
to external AC power.  
European Regulations  
Warning  
UTP/STP  
This is a Class A product. In a domestic environment this product may cause radio interference in which  
case the user may be required to take adequate measures.  
Fiber  
UTP/STP Blinking green LED  
indicates network traffic on unshielded or shielded twisted-pair  
link.  
Copyright Restrictions  
© 1998 TRANSITION Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any means –  
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.  
Fiber  
Blinking green LED indicates network traffic on fiber link.  
Trademark Notice  
*See note at top of pages 4 & 5.  
All registered trademarks and trademarks are the property of their respective owners.  
33060.A  
PS-CF-01  
3. Connect second PS-CF-01 media converter to terminal equipment  
TROUBLESHOOTING SUGGESTIONS  
If a Media Converter fails, ask the following questions:  
1. Is the Power LED on the media converter illuminated?  
NO  
through copper cable.  
UTP to RJ-45 Connector:  
If connecting to RJ-45 connector on terminal equipment (as on  
front of PowerStar™ III or PowerStar™ IV):  
Is the power adapter the proper voltage and cycle frequency  
for the AC outlet? NOTE: Refer to the “Power Supply  
Requirements” on the back page.  
Is the power adapter properly installed in the media converter  
and in the outlet?  
Connect male RJ-45 plug connector to female RJ-45 connector  
marked “link” on terminal equipment.  
UTP to Twinax Connector:  
Contact Technical Support: (800) 260-1312/(800) LAN-  
WANS.  
If connecting to twinax connector on terminal equipment (as on  
back of PowerStar™ III or on PowerStar™ IV with Twinax SIC):  
YES  
Proceed to step 2.  
NOTE: Install TRANSITION Networks balun part number: 3-4554  
between RJ-45 cable and Twinax connector.  
2. Is the UTP/STP LED illuminated?  
NO  
Install balun at terminal equipment Twinax connector.  
Connect male RJ-45 plug connector to balun.  
Check twisted pair cables for proper connection.  
Check RJ-45 connector for correct twisted pair cable  
configuration.  
4. Connect PS-CF-01 media converter(s) to power.  
Contact Technical Support: (800) 260-1312/(800) LAN-  
WANS.  
Locate correct power supply adapter for site installation. (See  
back page.)  
YES  
Proceed to step 3.  
Connect PS-CF-01 power connector at end of power supply  
adapter cord to PS-CF-01 power receptacle.  
3. Is the Fiber LED illuminated?  
NO  
Check fiber cables for proper connection.  
Connect 2-prong or 3-prong external power connector on  
other end of power supply adapter cord to external AC power.  
Verify that TX and RX cables on media converter are  
connected to RX and TX ports, respectively, on other device.  
Contact Technical Support: (800) 260-1312/(800) LAN-  
WANS.  
YES  
Contact Technical Support: (800) 260-1312/(800) LAN-  
WANS.  
3
6
PS-CF-01  
NOTE: DEVICES INSTALLED AT MAXIMUM DISTANCES MAY NOT  
FUNCTION RELIABLY DUE TO LIMITATIONS IMPOSED BY HOST  
TIME-OUTS AND/OR BY TERMINAL EQUIPMENT TIME-OUTS.  
up to 762 meters  
U T P / S T P  
F i b e r  
up to 762 meters  
AS/400  
S/3x  
or  
Multimode up to 2 kilometers  
Singlemode up to 8 kilometers  
5x94  
U T P / S T P  
F i b e r  
PowerStar™ III  
PowerStar™ IV  
RJ-45 copper/balun  
connection to Twinax  
connector at PowerStar™  
III back OR to Twinax  
SIC at PowerStarIV  
back  
3
up to 762 meters  
up to 762 meters  
U T P / S T P  
F i b e r  
Multimode up to 2 kilometers  
Singlemode up to 8 kilometers  
MEDIA CONVERTERS in the NETWORK  
PowerStar™  
PS-CF-01 series media converters can be installed:  
In pairs that connect, through copper cable, RJ-45 connectors, and baluns, then  
through fiber, and then through copper cable and RJ-45 connectors, a 5250-  
compliant host with a PowerStar™ III or PowerStar™ IV hub.  
RJ-45 copper connection  
at PowerStarIII or  
1
2
1
PowerStarIV front  
up to 762 meters  
As a single media converter that extends network distance, through copper cable,  
an RJ-45 connector and balun AND through fiber, between a 5250-compliant host  
and a PowerStar™ IV hub that has an installed fiber SIC card.  
Multimode up to 2 kilometers  
2
TX/RX connection  
to fiber SIC at  
In pairs that connect, through copper cable, RJ-45 connectors, and baluns AND  
through fiber, a 5250-compliant host and the Twinax connector at the back of a  
PowerStar™ III hub OR a PowerStar™ IV hub that has an installed Twinax SIC card.  
3
PowerStarIV back  
PowerStar™ IV  
5
4

Winegard Car Satellite TV System MM 3002 User Manual
Vivitar Camera Lens V 800MR User Manual
Uniden BT110 User Manual
Transcend Information TS8GSDHC 6 User Manual
Toshiba TEC MA 1900 User Manual
SWR Sound Workingman's Series Bass Speaker 1X10T User Manual
Sony MT4037S User Manual
Sony Handycam DCR HC96E User Manual
Sony D E525 User Manual
Sony Car Stereo System 85P User Manual