INSTALLATION AND OPERATION INSTRUCTIONS
FLAT TOP BOTTLE COOLER
MODEL NOS.
BC24 Series
BC36 Series
BC48 Series
BC60 Series
BC72 Series
BC96 Series
IMPORTANT INFORMATION
Table of Contents
Cabinet Specifications ..........................................2
Installing
This manual has been prepared to assist you in the
installation of your Bottle Cooler and to acquaint you
with its operation and maintenance.
Uncrating and Inspection ................................3
Plumbing .........................................................3
Electrical..........................................................3
Adjusting Partitions .........................................3
Installing Casters and Legs.............................3
Placing the Cabinet.........................................3
Sealing to the Floor.........................................3
Temperature Control .............................................4
Cleaning the Cabinet ............................................4
Wiring Diagram .....................................................5
Replacement Parts ............................................6/7
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, call Perlick at
1-800-777-7267 or your dealer who can provide you
with a list of qualified service agents. For your own
protection, never return merchandise for credit with-
out our approval.
We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction.
IMPORTANT WARRANTY INFORMATION
A Warranty card is enclosed that must be completed
and mailed to the Perlick Corporation to register the
warranty. If the card is not returned to Perlick, the
warranty period will begin from the date the
equipment is shipped from the factory.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Form No. Z2219
Rev. 4.15.06
Preparing the Cabinet – Flat Top Bottle Coolers
Uncrating and Inspection
Placing the Cabinet
Remove all crating material before operating.
Carefully inspect cabinet for hidden damage.
If damage is discovered, file your claim immediately
with the transport company. Perlick is not
responsible for damage in transit.
To assure maximum performance, fresh air must
be allowed to circulate through the machinery
compartment. It is important to allow at least two
inches of clearance at the back or left end of the
cabinet. Do not place anything in front of the
cabinet that would obstruct air flow at these grilles.
Do not place the unit in an unventilated small room.
Plumbing
CAUTION:
No plumbing connections are required. Condensate
from the cooling coil automatically evaporated
through a condensate pan located in the
condensing unit section.
Removing the factory installed back clearance
spacers without providing proper left side grill
clearance for compressor air flow will void
the warranty.
Cabinet should be leveled.
Electrical
For sanitation purposes, it may be necessary to
seal the base of the cabinet to the floor. This
can be accomplished by laying a bead of silicone
sealant along the base of the cabinet as shown
by the figure below.
The cabinet must be connected to a separately
fused power source (see Electrical Specification
Plate) and grounded in accordance with National
and Local Electrical Codes.
CAUTION: Do not attempt to operate the equipment
on any other power source than that listed on the
Electrical Specification Plate.
Adjustable Partitions
Perlick Bottle Coolers are provided with adjustable
partitions which will accommodate various bottle
sizes.
CABINET
■ Remove bottles and cans from their cases
before placing in cooler to ensure proper
air flow.
BEAD SILICON
SEALER (RTV)
■ On 2’ and 3’ models keep air intake open for
proper circulation.
FLOOR
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in holes
provided. Use the supplied 1⁄4”–20 hex head self-
tapping machine screws. If unit is tipped on its back
for an extended period of time, wait 24 hours after
unit is uprighted to plug the unit in.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
Rev. 4.15.06
3
How To Operate – Flat Top Bottle Coolers
Temperature Control
Cleaning the Doors:
An adjustable temperature control is located inside
the Bottle Cooler on the evaporator fan panel
assembly. It is factory set at “Normal” approximately
38° F. Make adjustments as shown to attain the
desired temperature.
NOTE: A temperature setting that is too low will not
allow enough condensing unit “off” time to maintain
a frost-free coil.
■ Doors should be periodically removed from the
cabinet and inspected for a buildup of foreign
materials, such as syrups, beer, etc. Buildups
on the underside of the doors, along with the
cabinet breaker strips on which they ride, will
cause them to bind, and therefore, not function
as designed. If dirty, these surfaces should be
cleaned with a mild detergent and water and
then coated with a silicone lubricating material.
Aerosol silicone sprays can be obtained locally
at most department or automotive stores.
To remove doors:
■ Colder Temperatures: Turn the adjusting
screw clockwise (to the right).
■ Warmer Temperatures: Turn the adjusting
screw counterclockwise (to the left).
■ Temperature Control “OFF”: Turn the
adjusting screw completely counterclock-
wise to the “O” position until a “click” is
noted.
■ With door closed, lift it upward by its handle and
slide forward until door clears the cabinet top.
Use the reverse procedure to reinstall the doors.
Cleaning the Cabinet:
■ Use a damp cloth with a mild detergent and
water to clean the inside and outside of the
cabinet. Dry thoroughly. Do not allow cleaning
agents or large amounts of water to go down
the drain. Use an acceptable stainless steel
polish to clean all stainless steel surfaces.
Never use steel wool or scouring pads to clean
stainless steel.
The condenser fan motor turns off and on with
the compressor. The evaporator fan motor runs
continuously.
Cleaning the Condenser:
■ The condenser (located behind the front
grille) should be inspected every 30 days,
and cleaned, if necessary. Failure to keep
the condenser clean will cause a loss in
condensing unit efficiency, or compressor
failure.
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain
chemicals or objects which will cause stainless steel corrosion.
STAINLESS STEEL ENEMY
■ Steel wool or steel scouring pads
■ Cherry/Orange/Olive juice
■ Chlorine Bleach
■ Sharp Objects
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
4
Rev. 4.15.06
Wiring Diagram – Flat Top Bottle Coolers
EVAP.
FAN
WHITE
TEMPERATURE
CONTROL
EVAP.
FAN
2ND FAN ON
4’THRU 8’ MODELS
WHITE
BLACK
BLACK
RED
GREEN
PLUG-IN-CORD
TO CONDENSING UNIT
INSIDE OF
CONDENSING
UNIT HOUSING
INSIDE OF
CABINET
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
Rev. 4.15.06
5
Replacement Parts – Flat Top Bottle Coolers
7
23
9
5A
14
19
8
17
5
4
6
21
18
22
20
12
13
1
10
11
2
3
15
CAUTION
■ Service should be done by a qualified
refrigeration technician.
■ Disconnect all power before servicing
the cabinet.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
Rev. 4.15.06
6
Replacement Parts – Flat Top Bottle Coolers
MODEL NOS.
BC24
BC36
BC48
BC60
BC72
BC96
Item Description
Part Numbers
Complete condensing unit
C22648
C22648
C22647
513200314
215315009
219101538
MRT20AGK5590
213516191
13556529
N/A
C22646
C22646
C22646
1
2
Replacement compressor R134a
Condensing unit fan motor assy.
Terminal board
Overload protector
Relay
Start capacitor (282-339MFD)
Start capacitor (378-454MFD)
Condensate pan
513307046
215315009
219101538
4TM762NFBZZ-53
213514067
N/A
N/A
64537
63608-1
C15239A
65060-1
63461
513307046
215315009
219101538
513200003
215315009
219101538
MRT22AFZ5590
213516051
N/A
13556539
64626-1
63608-4
(2) C15239A (2) C15239A (2) C15239A
(2) 60988-1
(2) 57699
C17511-2EP C17511-2EP C17511-2EP
C15046
61283
64644-1
64643-1
66397-24L
66397-36L
63564
513200003
215315009
219101538
513200003
215315009
219101538
213514067
N/A
213516051
N/A
13556539
64626-1
63608-5
213516051
N/A
13556539
64626-1
63608-6
N/A
3
4
5
5A
6
7
8
9
10
11
12
64626-1
63608-2
C15239A
65060-1
63461
64626-1
63608-3
Breaker strip kit
Evaporator fan motor
Evaporator fan motor bracket
Evaporator fan blade
Evaporator coil
Light bulb (when supplied)
Temperature control
Back grille
Front grille
Door assembly
Door assembly (multiple doors)
Door Lock
(2) C15239A
(2) 60988-1
(2) 57699
C17511-1EP
C15046
61283
64644-1
64643-1
(2) 60988-1
(2) 57699
(2) 60988-1
(2) 57699
64785-1EP C17511-1EP
C15046
61283
C15046
61283
64644-1
64643-1
66397-36L
N/A
C15046
61283
64644-1
64643-1
C15046
61283
64644-1
64643-1
N/A
64167A-1
66397-24L
N/A
(2) 66397-24L
N/A
(2) 66397-36L (2) 66397-36L
N/A
63564
66397-24L
63564
13
14
15
16
17
18
19
20
21
22
63564
63564
63564
Top wiper gasket
63671-24
64814-1
64815-1
N/A
65017-24
65016-24
64813-1
C6713-1
C17332
63671-36
64814-1
64815-1
65013-36
65017-36
65016-36
(2) 64719-1
C6713-1
C17332
63671-48
64814-1
64815-1
65013-48
65017-48
65016-48
(2) 64719-1
C6713-1
63671-60
64814-1
64815-1
65013-60
65017-60
65016-60
(3) 64719-1
C6713-1
C17332
63671-72
64814-1
64815-1
65013-72
65017-72
65016-72
(4) 64719-1
C6713-1
C17332
63671-96
64814-1
64815-1
65013-96
65017-96
65016-96
(6) 64719-1
(2) C6713-1
(2) C17332
Bottom floor rack (wide)
Bottom floor rack (narrow)
Top front rail
Bottom front rail
Back rail
Divider rack
Bottle cap opener
Bottle cap holder
C17332
22A Bottle cap holder screws
22B Bottle cap holder spacers
(2) M00504-122 (2) M00504-122 (2) M00504-122 (2) M00504-122 (2) M00504-122 (4) M00504-122
(2) C122-2
64692-24A
(2) C122-2
64692-36A
(2) C122-2
64692-48A
(2) C122-2
64692-60A
(2) C122-2
64692-72A
(4) C122-2
64692-96A
23
Back top assembly
Items Not Shown
Wire harness
65043-1
63553-1
63554-1
65043-1
63553-1
63554-1
65044-1
63553-1
63554-1
65044-1
63553-1
63554-1
65044-1
63553-1
63554-1
65044-1
63553-1
63554-1
Evaporator tube (11⁄4” U. bend)
Evaporator tube (41⁄8” U. bend)
Cap tube/suction line heat
exchanger with dryer
65072
65072
65073
65075
65075
65075
Mullion assembly
Light kit (accessory only)
Refrigerant charge (oz. R134a)
—
63536
6.0
—
63536
8.5
64823R
63536
9.0
64823R
63536
9.0
64823R
63536
9.0
(2) 64823R
63536
9.0
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
Rev. 4.15.06
7
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2219
Rev. 4.15.06
|