Panasonic HHR210A User Manual

NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET  
Typical Charge Characteristics  
HHR210A  
Cylindrical A size (HR 17/50)  
2.0  
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
Dimensions (with Tube)  
(mm)  
Charge: 2100mA(1 It)1.2hrs.  
17.0+0  
0.7  
-
0˚C  
20˚C  
40˚C  
(+)  
0
10 20 30 40 50 60 70 80 90 100 110 120  
Charge Time (minutes)  
50.0+0  
1.5  
-
Typical Discharge Characteristics  
1.8  
Charge: 2100mA(1 It)1.2hrs,20˚C  
Discharge Temperature: 20˚C  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
( )  
Specifications  
mm  
inch  
420mA(0.2 It)  
17.0+0/-0.7  
50.0+0/-1.5  
Grams  
0.67+0/-0.03  
1.97+0/-0.06  
Ounces  
Diameter  
Height  
0
1
2
3
4
5
6
Discharge Time (hours)  
Approximate  
Weight  
38  
1.34  
Nominal Voltage  
1.2V  
1.8  
Charge: 2100mA(1 It)1.2hrs,20˚C  
Discharge Temperature: 20˚C  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
Average**  
2200 mAh  
2100 mAh  
Discharge  
Capacity*  
Rated (Min.)  
Approx. Internal impedance  
at 1000Hz at charged state.  
20m  
210mA (0.1It) x 16hrs.  
2100mA (1It) x 1.2 hrs.  
Standard  
Charge  
Rapid  
2100mA(1 It)  
4200mA(2 It)  
F
˚
C
˚
Standard  
Charge  
0˚C to 45˚C  
0˚C to 40˚C  
32˚F to 113˚F  
32˚F to 104˚F  
14˚F to 149˚F  
-4˚F to 95˚F  
-4˚F to 113˚F  
-4˚F to 131˚F  
0
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
Rapid  
Discharge  
< 1 year  
Discharge Time (minutes)  
-10˚C to 65˚C  
-20˚C to 35˚C  
-20˚C to 45˚C  
-20˚C to 55˚C  
Storage  
< 3 months  
< 1 month  
* After charging at 0.1It for 16 hours, discharging at 0.2It.  
** For reference only.  
Battery performance and cycle life are strongly affected by how they  
are used. In order to maximize battery safety, please consult Panasonic  
when determining charge / discharge specs, warning label contents  
and unit design.  
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression  
for the amount of charge or discharge current and is expressed as:  
It(A) = Cn (Ah)/1h.  
• [It] is the reference test current in ampres  
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.  
n = the time base [hours] for which the rated capacity is declared  
AUGUST 2005  
NICKEL METAL HYDRIDE HANDBOOK  
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to  
modification without notice. Contact Panasonic for the latest information.  

Rockford Fosgate FRC3246 User Manual
Plantronics Bluetooth Headset M165 User Manual
Pioneer GM 3200T User Manual
Philips Car Video System 192E+04 User Manual
Peavey Electronics Car Amplifier 3000 User Manual
Panasonic AK HC1800MC User Manual
Panasonic AG HVX200MC User Manual
McAfee VIRUSSCAN 87I User Manual
Kenwood Car Stereo System KDC 400U User Manual
JVC KS FX701 User Manual