Panasonic HHR120AA User Manual

NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET  
Typical Charge Characteristics  
HHR120AA  
Cylindrical 4/5AA size (HR 15/43)  
2.0  
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
Dimensions (with Tube)  
(mm)  
Charge: 600mA(1 It)1.2hrs.  
14.5+0  
0.7  
-
0˚C  
20˚C  
45˚C  
(+)  
0
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
Charge Time (minutes)  
43.0+0  
1.0  
-
Typical Discharge Characteristics  
1.8  
Charge: 1200mA(1 It)1.2hrs,20˚C  
DischargeTemperature: 20˚C  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
( )  
Specifications  
240mA(0.2 It)  
mm  
inch  
14.5+0/-0.7  
43.0+0/-1.0  
Grams  
0.57+0/-0.03  
1.69+0/-0.04  
Ounces  
Diameter  
Height  
0
1
2
3
4
5
6
Discharge Time (hours)  
Approximate  
Weight  
23  
0.81  
Nominal Voltage  
1.2V  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1.0  
0.9  
0.8  
Charge: 1200mA(1 It)1.2hrs,20˚C  
Discharge Temperature: 20˚C  
Average**  
Rated (Min.)  
1220 mAh  
1150 mAh  
Discharge  
Capacity*  
Approx. Internal impedance  
at 1000Hz at charged state.  
19m  
120mA (0.1It) x 16hrs.  
1200mA (1It) x 1.2 hrs.  
Standard  
Charge  
Rapid  
1200mA(1 It)  
2400mA(2 It)  
F
˚
C
˚
Standard  
Charge  
0˚C to 45˚C  
0˚C to 40˚C  
32˚F to 113˚F  
32˚F to 104˚F  
14˚F to 149˚F  
-4˚F to 95˚F  
-4˚F to 113˚F  
-4˚F to 131˚F  
0
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
Rapid  
Discharge  
< 1 year  
Discharge Time (minutes)  
-10˚C to 65˚C  
-20˚C to 35˚C  
-20˚C to 45˚C  
-20˚C to 55˚C  
Storage  
< 3 months  
< 1 month  
* After charging at 0.1It for 16 hours, discharging at 0.2It.  
** For reference only.  
Battery performance and cycle life are strongly affected by how they  
are used. In order to maximize battery safety, please consult Panasonic  
when determining charge / discharge specs, warning label contents  
and unit design.  
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression  
for the amount of charge or discharge current and is expressed as:  
It(A) = Cn (Ah)/1h.  
• [It] is the reference test current in ampres  
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.  
n = the time base [hours] for which the rated capacity is declared  
AUGUST 2005  
NICKEL METAL HYDRIDE HANDBOOK  
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to  
modification without notice. Contact Panasonic for the latest information.  