QA6ADP QA Conversion
Adapter Module
User’s Manual
QA6ADP
Thank you for buying the Mitsubishi general-purpose programmable
logic controller MELSEC-Q Series
Prior to use, please read both this manual and detailed manual
thoroughly and familiarize yourself with the product.
MODEL
MODEL
CODE
QA6ADP-U-JE
13JY50
IB(NA)-0800402-B(0803)MEE
© 2007 MITSUBISHI ELECTRIC CORPORATION
CONTENTS
1. OVERVIEW....................................................................................................3
1.1 Overview ...............................................................................................3
1.2 Included Parts .......................................................................................3
2. SYSTEM CONFIGURATION .........................................................................4
2.1 System Configuration............................................................................4
2.2 Configuration Device List.......................................................................5
3. SPECIFICATIONS .........................................................................................7
3.1 General Specifications...........................................................................7
3.2 Performance Specifications...................................................................8
4. PART NAMES AND SETTING.......................................................................9
4.1 Part Names ...........................................................................................9
4.2 Extension Stage Number Setting.........................................................10
5. IMPLEMENTATION AND INSTALLATION...................................................11
5.1 Mounting/Removal of QA6ADP ...........................................................11
5.2 Connection/Disconnection of Extension Cable ....................................13
6. PRECAUTION FOR USING QA6ADP..........................................................16
6.1 Current Consumption of QA6ADP.......................................................16
6.2 Voltage Drop of Extension Cable.........................................................17
7. EXTERNAL DIMENSIONS...........................................................................18
GENERIC TERMS AND ABBREVIATIONS
Unless otherwise specified, this manual uses the following generic terms
and abbreviations to explain the QA conversion adapter module.
Generic term/Abbreviation
A5 B
Description
Generic term for A52B, A55B, and A58B
extension base units on which A series I/O
module and special function module can be
mounted without power supply.
Generic term for A62B, A65B, and A68B
extension base units on which A series I/O
module and special function module can be
mounted.
A6 B
Abbreviation for QA6ADP QA conversion
adapter module.
QA6ADP
Abbreviation for A large type extension base unit
on which QA6ADP is mounted.
QA6ADP+A5 B/A6 B
2
1. OVERVIEW
1.1 Overview
This user’s manual describes the specifications, configuration device, part
names and setting, and implementation and installation of the QA6ADP QA
conversion adapter module.
For contents that are not described in this manual such as safety precautions,
EMC and low voltage directives, or error code list, refer to QCPU User’s Manual
(Hardware Design, Maintenance and Inspection) (SH-080483).
The QA6ADP is the adapter module connecting the A (large type) series
extension base unit to the Q series main base unit.
Q3 B
A3 B
Replace CPU with QCPU
QA6 B
Replace the main base unit (A3 B)
with the extension base unit (QA6 B)
A6 B
A6 B
Mount the QA6ADP on the
extension base unit (A6 B)
QA6ADP
POINT
• The QA6ADP is CE-compliant. To meet the EMC directive, the extension
base unit and module to be used in combination with the QA6ADP should
be CE-compliant.
• When using a control line or communication cable, keep it away from the
main circuit or power line 100mm or more.
Failure to do so may cause malfunction due to noise.
1.2 Included Parts
This section describes parts included with this module.
Product name
Model
Quantity Remarks
QA6ADP QA conversion adapter module QA6ADP
1
1
1
1
1
---
---
---
---
---
Adapter module mounting bracket
Mounting bracket fixing screw
Board fixing screw
---
---
---
---
This manual
3
2. SYSTEM CONFIGURATION
2.1 System Configuration
This section describes the system configuration and restrictions when the
QA6ADP is used.
(1) The QA6ADP+A5 B/A6 B is only applicable for the High Performance
model QCPU (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, and
Q25HCPU).
(2) Mount the Q5 B/Q6 B, QA6 B, and QA6ADP+A5 B/A6 B in order
from the nearest position of the main base unit.
The QA6ADP cannot be used in combination with the QA1S6 B.
(3) The number of slots of the QA6ADP+A5 B/A6 B is always displayed in 8
slots, regardless of the number of slots of the extension base unit to be
used in combination with the QA6ADP.
Assign the I/O number of a module, putting each series in block and in
order of "Q series A series" or "A series Q series".
Failure to do so may cause an error (SP.UNITLAY ERR).
In addition, do not duplicate the I/O number.
(4) For the extension stage number setting of the extension base unit, set
stage number (the first to seventh stages) to extension stages from the
one nearest to the main base unit.
(5) An extension cable connectable to the QA6ADP is the Q series extension
cable only.
(6) Set the same stage number to both the stage number setting connector of
the extension base unit and that of the QA6ADP.
(7) The QA6ADP+A5 B/A6 B cannot be used as the MELSECNET/H
remote I/O station.
(8) The bus connection with GOT is not available for the QA6ADP+A5 B/
A6 B.
[Extension stage number setting]
Stage number setting connector
High Performance model QCPU
0
1
2
3
4
5
6
7
Q38B
Q68B
QA68B
A68B
Main base unit
8
9
10 11 12 13 14 15
1
2
3
Q series compatible extension base unit
(The Q5 B/Q6 B is connected to the
main base unit or the Q5 B/Q6 B.)
16 17 18 19 20 21 22 23
A series compatible extension base unit
(The QA6 B is connected to the main
base unit, the end of the Q5 B/Q6 B,
or the QA6 B.)
24 25 26 27 28 29 30 31
A series compatible extension base unit
(The QA6ADP+A5 B/A6 B is connected
to the main base unit, the end of the
Q5 B/Q6 B/QA6 B, or the QA6ADP
+A5 B/A6 B.)
QA6ADP
4
2.2 Configuration Device List
(1) Extension base unit mountable on the QA6ADP
The following shows extension base units that can be mounted on the
QA6ADP.
Product name
Extension base unit
(Power supply module not A55B-UL,
mounting type)
Extension base unit
(Power supply module
mounting type)
Model
A55B,
A58B-UL
Remarks
A52B,
A58B,
A68B,
----
A62B,
A65B-UL,
A65B,
A68B-UL
----
(2) Module mountable on the extension base unit where the QA6ADP is
mounted
The following shows modules that can be mounted on the extension base
unit where the QA6ADP is mounted.
Product name
Power supply module
Model
A61PN,
A61PEU,
Remarks
----
A61P,
A63P,
A68P
A62P,
A62PEU
Power supply module
(I/O slot mounting type)
AC input module
----
AX10,
AX20,
AX11,
AX21,
AX11EU,
AX21EU
*6
AC/DC input module
DC input module
AX31,
AX40,
AX42,
AX60-S1,
AX80,
AX81-S1,
AX81B,
AY10,
AY11A,
AY11EEU, AY13,
AX31-S1
AX41,
AX42-S1,
AX70,
AX80E,
AX81-S2,
AX82
AY10A,
AY11E,
----
AX41-S1,
AX50-S1,
AX71,
AX81,
AX81-S3,
----
Contact output module
Triac output module
AY11,
AY11AEU,
AY13E,
----
----
AY13EU,
AY22,
AY15EU
AY23
Transistor output module AY40,
AY42,
AY40A,
AY42-S1,
AY42-S4,
AY51-S1,
AY60E,
AY72,
AY41,
AY42-S2,
AY50,
AY60,
AY70,
AY80,
AY42-S3,
AY51,
AY60S,
AY71,
AY81,
A42XY
AH42
----
AY82EP
Dynamic I/O module
Combined I/O module
----
----
5
Product name
High-speed counter
module
Model
AD61S1
Remarks
*1
AD61,
A/D converter module
A68AD,
A616AD
A62DA,
A68AD-S2, A68ADN,
----
----
----
D/A converter module
A62DA-S1, A68DAV,
A68DAI-S1, A616DAV, A616DAI
A68RD3N, A68RD4N, A616TD,
A60MX,
AI61,
Temperature-digital
converter module
Interrupt module
A60MXRN, A60MXTN
AI61-S1
*2
Positioning module
AD70,
AD72
----
AD75M1,
AD75M2,
AD75M3,
*1
*3 *4
*1
AD75P1-S3, AD75P2-S3, AD75P3-S3
A-A1S module conversion A1ADP-XY, A1ADP-SP
adapter
MELSECNET/MINI-S3
master module
AJ71PT32-S3,
AJ71T32-S3
Intelligent communication AD51,
AD51-S3,
AD51H,
*2
module
AD51H-S3
PC fault detection module AS91
MELSEC-I/OLINK module AJ51T64
----
----
----
----
----
B/NET interface module
Blank cover
AJ71B62-S3
AG60
AG62
Dummy module
*1: The dedicated instructions used in the QnA/A series program cannot be used in the
QCPU.
Replace the dedicated instructions with the FROM/TO instructions.
*2: There is restriction on the number of mountable modules.
No. of mountable
Product name
Model
AD51-S3,
modules
Intelligent communication AD51,
module
Interrupt module
6
AD51H,
AI61,
AD51H-S3
AI61-S1
1 *5
*3: Using the A-A1S module conversion adapter enables to use modules equivalent to the
AnS module by the module shown in the table. For the mountable modules, refer to
A-A1S Module Conversion Adapter User's Manual (IB-0800352).
*4: Only the multidrop link function can be used with the A1SJ71UC24-R4+A1ADP.
*5: The interrupt module can use only one out of the QI60 (when mounted on the Q3 B,
Q5 B or Q6 B), AI61, and AI61-S1.
*6: The normal operation of A series AC input module can be guaranteed only when the base
unit on which the A series power supply module is mounted exists in the system.
Make sure that the following condition is satisfied when A series AC input module is used.
y A series AC input module is mounted on the QA6 B or QA6ADP+A6 B.
y A series AC input module is mounted on the QA6ADP+A5 B. However, A series
compatible extension base unit, QA6 B or QA6ADP+A6 B, exists in the system.
6
3. SPECIFICATIONS
3.1 General Specifications
This section describes general specifications of the QA6ADP.
Item
Specifications
Operating ambient
temperature
0 to 55
Storage ambient
temperature
-20 to 75
Operating ambient
humidity
10 to 90 % RH, No-condensing
Storage ambient
humidity
10 to 90 % RH, No-condensing
Accelera
Sweep
count
Frequency
Amplitude
-tion
Conforming Under
10 times
each in
X, Y, Z
directions
(for 80
10 to 57 Hz
57 to 150 Hz 9.8 m/s2
----
0.075 mm
----
Vibration
resistance
to
intermittent
JIS B 3502, vibration
IEC 61131-2
Under
00.35 mm
(0.001 in.)
----
10 to 57 Hz
57 to 150 Hz 4.9 m/s2
----
continuous
vibration
min).
Conforming to JIS B 3502, IEC 61131-2
Shock resistance
(147 m/s2, 3 times in each of 3 directions XYZ)
Operation
ambiance
Operating
elevation *3
Installation
location
No corrosive gasses
2000 m (6562 ft.) or less
Control panel
Overvoltage
category *1
Pollution degree *2
Equipment
category
II max.
2 max.
Class I
*1: This indicates the section of the power supply to which the equipment is assumed
to be connected between the public electrical power distribution network and the
machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed
facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*2: This index indicates the degree to which conductive material is generated in terms
of the environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary
conductivity caused by condensing must be expected occasionally.
*3: Do not use or store the PLC in the environment when the pressure is higher than
the atmospheric pressure at sea level.
Otherwise, malfunction may result.
To use the PLC in high-pressure environment, please contact your local Mitsubishi
Repress entative.
7
3.2 Performance Specifications
This section describes performance specifications of the QA6ADP.
Item
Specifications
5VDC internal current
consumption
110 mA
130 mm (5.11 inch) (H)
73.5 mm (2.89 inch)
External dimensions *1
(W)
74 (2.91 inch) mm (D)
Weight
0.2 kg
Adapter mounting screw
(M3) torque
Board fixing screw
torque
0.36 to 0.48 N•m
0.61 to 0.82 N•m
*1:The external dimensions show values in a status where the QA6ADP is
mounted on the extension base unit.
8
4. PART NAMES AND SETTING
4.1 Part Names
This section describes part names of the QA6ADP.
9)
8)
3)
1)
7)
6)
2)
4)
5)
3)
No.
1)
Name
Application
Connector for sending/receiving signals to the main
base unit or the other extension base unit and
connecting an extension cable.
Extension cable
connector
Stage number
setting connector
Adapter module
2)
Connector for setting the number of extension stages.
Screw for mounting this adapter module on the
extension base unit.
3) mounting screw
(M3 screw)
Bracket for mounting this adapter module on the
extension base unit. Utilize screws used in the
extension base unit. (Included parts)
Adapter module
4)
mounting bracket
Mounting bracket
fixing screw
Screw for mounting an adapter module mounting
bracket on the extension base unit. (Included parts)
5)
Base side stage
6) number setting
connector window
Window is transparent so that a stage number setting
connecter of the extension base unit side can be seen.
Extension base unit Connector to be connected to the A extension cable I/O
mounting connector connecter of the extension base unit.
Screw for mounting this adapter module on the
7)
8) Board fixing screw
9) Mounting guide
extension base unit. (Included parts)
Guide for positioning an extension base unit mounting
connector by inserting this into a cover fixing square
hole of the extension base unit at the time of mounting.
9
4.2 Extension Stage Number Setting
Set the number of extension stages to both the QA6ADP and the extension
base unit.
The same stage number should be set to both the stage number setting
connector of the extension base unit and that of the QA6ADP.
POINT
Set any number of 1 to 7 which matches to the number of extension stages
for the stage number setting connector setting. If the stage number setting of
the QA6ADP and that of the extension base unit is different, the two or more
settings are made to one stage, the same stage number is duplicated, or no
setting is made to the number of stages, incorrect input or incorrect output will
occur.
(1) Extension stage number setting of the QA6ADP
The following describes how to set the number of extension stages of the
QA6ADP.
Extension stage number setting
1st
stage
2nd
stage
3rd
4th
5th
6th
stage
7th
stage
stage
stage
stage
Stage number
setting connector
setting
(2) Extension stage number setting of the extension base unit
Remove a base cover from the
extension base unit.
Insert a connector pin into the place of
the stage number selected from 1 to 7
of the connector (CON3) at bottom left
of the base unit.
Completed
Stage number setting connector
Extension stage number setting
1st
stage
2nd
stage
3rd
4th
5th
6th
stage
7th
stage
stage
stage
stage
Stage number
setting connector
setting
10
5. LOADING AND INSTALLATION
5.1 Mounting/Removal of QA6ADP
(1) Mounting of the QA6ADP
The following shows procedures for mounting the QA6ADP on the
extension base unit.
Disconnect the A series extension cable
from the extension base unit.
A)
Remove a base cover from the extension
base unit.
Set the stage number setting connector of
the extension base unit.
Set the stage number setting connector of
the QA6ADP. (The setting should be same
as that of the stage number setting
connector of the extension base unit.)
In case of the A5 B, disconnect a lead of
the FG terminal (right side).
Among screws fixing a board of the
extension base unit, remove two at the
left. (Screws A and B shown in the figure.)
Utilize a mounting bracket fixing screw to
mount the adapter module mounting
bracket of the QA6ADP into a screw hole
(B) at the bottom left of the board.
B)
Board fixing screw
Mount a board fixing screw of the QA6ADP
to a screw hole (A) at top left of the board.
Connect an extension base unit mounting
connector of the QA6ADP to the IN side of
an extension connector of the extension
base unit.
Mounting
guide
Extension
base unit IN
side connector
Adapter module
mounting
bracket
Tighten the adapter module mounting
screws of the QA6ADP at two parts
(top and bottom), placing a mounting guide.
Mount an upper mounting screw to a
board fixing screw (at top left) of the
extension base unit.
Adapter module
mounting
screw
Mount a lower mounting screw to the
adapter module mounting bracket.
In case of the A5 B, connect the
disconnected lead of the FG terminal
(right side).
ounting bracket
M
fixing screw
QA6ADP
Adapter module
mounting screw
Connect the Q series extension cable to the
QA6ADP and the upper/lower base unit.
Completed
11
(2) Removal of the QA6ADP
The following shows procedures for removing the QA6ADP from the
extension base unit.
Board fixing screw
Disconnect an extension cable form the
QA6ADP.
Remove the adapter module mounting
screws of the QA6ADP at two parts (top
and bottom).
Mounting
guide
Extension
base unit IN
side connector
Remove the QA6ADP main body from the
extension base unit.
Adapter module
mounting
bracket
Remove a board fixing screw and an
adapter module mounting bracket of the
QA6ADP.
Adapter module
mounting
screw
Mount a screw fixing the board of the
extension base unit at two parts on the left.
ounting bracket fixing screw
M
Adapter module
mounting screw
Please a base cover over the extension
base unit.
QA6ADP
Completed
12
5.2 Connection/Disconnection of Extension Cable
(1) Precautions for handling an extension cable
• Do not step on an extension cable.
• When laying an extension cable, the minimum bend radius of the cable
should be 55 mm (2.17 inch) or more. If it is less than 55 mm (2.17 inch),
malfunction may occur due to characteristic deterioration, wire break
etc.
• When connecting or disconnecting an extension cable, do not hold
ferrite cores mounted at both ends of the cable. In case of
connecting/disconnecting a cable, hold the connector part of the cable.
Extension base unit
Connector
Ferrite core
Extension
cable
Holding a ferrite core may cause cable break inside the connector. Also, if
the ferrite core is shifted, the characteristic will change. When handling
the cable, take care not to change position of the ferrite core.
(2) Connection of extension cable
The following shows extension cables connectable to the QA6ADP.
Model
QC05B
QC06B
QC12B
QC30B
QC50B
QC100B
Remarks
0.45m cable
0.6m cable
1.2m cable
3m cable
5m cable
10m cable
POINT
When connecting the base unit of the previous stage and the QA6ADP with
an extension cable, be sure to connect the OUT side connector of the base
unit of the previous stage and the IN side connector of the QA6ADP.
If an extension cable is connected in the wrong way (IN IN, OUT OUT or
IN OUT), the system will not operate normally.
13
• To connect an extension cable to the QA6ADP, remove a sticker on the
IN side connector.
Base cover
Extension base unit
IN side
QA6ADP
Sticker
• To connect an extension cable to the OUT side connector of the
QA6ADP, remove the portion (lid) under the characters "OUT" by tools
such as a flathead screwdriver (5.5 75, 6 100).
Extension base unit
Base cover
Cutting one
OUT side
thin-walled part
QA6ADP
Flathead screwdriver
14
• Hold the connector part of an extension cable when connecting the
extension cable to the QA6ADP.
Extension base unit
QA6ADP
Connector
Extension cable
• Make sure to tighten fixing screws of the extension cable
connector after connecting the extension cable.
(Tightening torque: 0.20 N m)
Extension base unit
Flathead screwdriver
QA6ADP
Fixing
screw
(3) Disconnection of extension cable
When disconnecting an extension cable, hold and pull the connector part
of the extension cable after making sure that fixing screws have been
completely removed.
15
6. PRECAUTION FOR USING QA6ADP
6.1 Current Consumption of QA6ADP
Since 5VDC is supplied to the QA6ADP from the power supply module of the
main base unit, take the current consumption of the QA6ADP into consideration
when selecting the power supply module for the main base unit.
Current consumption of CPU
and I/O of main base unit
Current consumption
of I/O of Q5 B
Current consumption
of I/O of A5 B
Current consumption
of QA6ADP n
n: Quantity of QA6ADP in system*1
*1 The quantity of the QA6ADP includes the QA6ADP when the A6 B is used.
The following shows the concept of the current consumption of the power
supply module mounted on the main base unit.
Main base unit
Power
supply
module
I0
Extension base unit (QA6 B)
Power
supply
First extension stage
Second extension stage
Third extension stage
Fourth extension stage
module
I1
Extension base unit (A5 B)
IA
IA
IA
I2
Extension base unit (A5 B)
I3
Extension base unit (A6 B)
Power
supply
module
I4
Symbol
I
Description
Rated current of power supply module on the main base unit
Current consumption of CPU and I/O modules mounted on the main base
unit
I0
Current consumption of I/O mounted on the extension base unit in first to
fourth stages
Current consumption of the QA6ADP
I1 to I4
IA
In case of the above system, use the QA6ADP when the current consumption of
the power supply module mounted on the main base unit meets the following
formula.
[Calculating formula]
I
I0
I2
I3
IA
3
16
6.2 Voltage Drop of Extension Cable
Since 5VDC is supplied to the QA6ADP from the power supply module mounted
on the main base unit, the voltage drop will be caused in the extension cable.
If the specified voltage (4.75VDC or more) is not supplied to the IN side
connector of the QA6ADP+A5 B/A6 B, wrong input/output may occur.
When using the QA6ADP, check that the IN side connector of the
QA6ADP+A5 B/A6 B has 4.75VDC or more.
The following shows an example regarding how to calculate the voltage drop.
Main base unit
Power
supply
module
Conductor
resistance value
Extension base unit (QA6 B)
V1 R1
Model
Power
supply
module
I1
QC05B
QC06B
QC12B
QC30B
QC50B
QC100B
0.044
First extension stage
0.051
0.082
Extension base unit (A5 B)
V2 R2
V3 R3
IA
IA
0.172
Second extension stage
0.273
I2
0.530
Extension base unit (A6 B)
Power
supply
module
I3
Third extension stage
Symbol
V
Description
Sum of voltage drop
Voltage drop due to an extension cable between the main base unit and
the QA6 B
Voltage drop due to an extension cable between the extension base unit
(n-1th extension stage) and the extension base unit (nth extension stage)
Resistance value of a cable between the main base unit and the
extension base unit QA6 B
V1
Vn
R1
Rn
Resistance value of an extension cable between the extension base unit
(n-1th extension stage) and the extension base unit (nth extension stage)
I1 to I3 5VDC current consumption in the first to third stages *1
IA Current consumption of the QA6ADP
*1:Since the current consumptions I1 to I3 vary depending on modules to be
mounted, refer to the manual for the module to be mounted.
[Calculating formula]
V
V1
V2
V3
R1
( I2 IA
2 )
R2
( I2
IA
2 )
R3
IA
The minimum value of the 5VDC output voltage of the power supply module
mounted on the main base unit is set to 4.90VDC. Therefore, the voltage of the
IN side connector of the QA6ADP+A5 B/A6 B in the final stage is 4.75VDC or
more only when the sum (V) of voltage drop is 0.15V or less.
17
7. COMPATIBLE MODELS LIST
This chapter describes external dimensions of the QA6ADP.
A series extension base unit
that you have already had
2 6-M4 screw
(for mounting module) (M5 mounting screw)
4- 6mounting hole
QA6ADP QA conversion
adapter module
Handle
POWER
I/O
I/O
I/O
I/O
I/O
74 (2.91)
73.5 (2.89)
Power supply module, Extension cable
Power supply module
Extension cable
121 (4.76)
172 (6.77)
Unit: mm (inch)
18
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products;
damage, secondary damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to
other duties.
For safe use
y This product has been manufactured as a general-purpose part for general industries, and
has not been designed or manufactured to be incorporated in a device or system used in
purposes related to human life.
y Before using the product for special purposes such as nuclear power, electric power,
aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
y This product has been manufactured under strict quality control. However, when installing
the product where major accidents or losses could occur if the product fails, install
appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
Country/Region Sales office/Tel
U.S.A
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon
Hong Kong
Mitsubishi Electric Automation
(Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, Hong Kong
Tel : +852-2887-8870
Mitsubishi Electric Automation
(Shanghai) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
Shanghai 200003, China
Tel : +86-21-6120-0808
Setsuyo Enterprise Co., Ltd.
6F No.105 Wu-Kung 3rd.Rd, Wu-Ku
Hsiang, Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Mitsubishi Electric Automation Korea
Co., Ltd.
1480-6, Gayang-dong, Gangseo-ku
Seoul 157-200, Korea
Tel : +82-2-3660-9552
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building,
Singapore 159943
Tel : +65-6470-2460
Mitsubishi Electric Automation (Thailand)
Co., Ltd.
Bang-Chan Industrial Estate No.111
Moo 4, Serithai Rd, T.Kannayao,
A.Kannayao, Bangkok 10230 Thailand
Tel : +66-2-517-1326
P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A/Utara
No.1 Kav. No.11 Kawasan Industri
Pergudangan Jakarta - Utara 14440,
P.O.Box 5045 Jakarta, 11050 Indonesia
Tel : +62-21-6630833
Messung Systems Pvt, Ltd.
Electronic Sadan NO:III Unit No15,
M.I.D.C Bhosari, Pune-411026, India
Tel : +91-20-2712-3130
Hills, IL 60061, U.S.A.
Tel : +1-847-478-2100
MELCO-TEC Rep. Com.e Assessoria
Tecnica Ltda.
Brazil
China
Rua Correia Dias, 184,
Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8 D-40880 Ratingen,
GERMANY
Tel : +49-2102-486-0
Mitsubishi Electric Europe B.V. UK
Branch
Travellers Lane, Hatfield, Hertfordshire.,
AL10 8XB, U.K.
Tel : +44-1707-276100
Mitsubishi Electric Europe B.V. Italian
Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza.,
Milano, Italy
Tel : +39-039-60531
Mitsubishi Electric Europe B.V. Spanish
Branch
Carretera de Rubi 76-80,
E-08190 Sant Cugat del Valles,
Barcelona, Spain
Tel : +34-93-565-3131
Mitsubishi Electric Europe B.V. French
Branch
Taiwan
Korea
Germany
U.K
Singapore
Thailand
Italy
Spain
Indonesia
France
India
25, Boulevard des Bouvets, F-92741
Nanterre Cedex, France
TEL: +33-1-5568-5568
Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando,
South Africa
South Africa
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere,
N.S.W 2116, Australia
Tel : +27-11-928-2000
Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
|