| 036-21105-004 Rev. A (0902)   DESCRIPTION   ® The HDA Series condensing unit is the outdoor part of a ver-   satile system of air conditioning. It is designed to be custom-   matched with one of UPG's complete line of evaporator sec-   tions, each designed to serve a specific function. Matching   Air Handlers are available for upflow, downflow or horizontal   application to provide a complete system. Electric heaters are   available if required.   TECHNICAL GUIDE   STELLAR 2000   FEATURES   • QUALITY CONDENSER COILS - The coil is constructed   of enhanced copper tube and aluminum fins.   • COIL PROTECTION - Coils are protected from damage by   a polymer mesh applied between the coil face, and a PVC   coated steel coil guard.   SPLIT-SYSTEM AIR CONDITIONERS   10 SEER 50 HZ   • PROTECTED COMPRESSOR - The compressor is inter-   nally protected against high pressure and temperature.   This is accomplished by the simultaneous operation of   high pressure relief valve and a temperature sensor which   protect the compressor if undesirable operating conditions   occur.   MODELS: H*DA012 THRU H*DA076   (1 & 3 PHASE)   (1 THRU 7.5 NOMINAL TONS)   • DURABLE FINISH - Cabinet is made of pre-painted steel.   The pre-treated flat galvanized steel provides a better   paint to steel bond, which resists corrosion and rust creep.   Special primer formulas and glossy earth tone finish insure   less fading when exposed to sunlight.   • LOWER INSTALLED COST - Installation time and costs   are reduced by easy power and control wiring connec-   tions. Discharge line heat exchanger knockouts are pro-   vided, if required. Both quick connect and sweat connect   models are available. Both service valves are firmly affixed   to the unit. The sweat unit contains enough refrigerant for   matching indoor coils and 15 feet of interconnecting pip-   ing. The small base dimension means less space is   required on the ground or roof.   • TOP DISCHARGE - The warm air from the top mounted   fan is blown up away from the structure and any landscap-   ing. This allows compact location on multi-unit applica-   tions.   • LOW OPERATING SOUND LEVEL - The upward air flow   carries the normal operating noise up away from the living   area. The rigid top panel effectively isolates any motor   sound. Isolator mounted compressor and the rippled fins   of the condenser coil muffle the normal fan motor and   compressor operating sounds.   • LOW MAINTENANCE - Long life permanently lubricated   motor- bearings need no annual servicing.   • EASY SERVICE ACCESS - Fully exposed refrigerant con-   nections and a single panel covering the electrical controls   make servicing easy.   Due to continuous product improvement, specifica-   tions are subject to change without notice.   up-to-date technical information.   • SECURED SERVICE VALVES - Secured re-usable ser-   vice valves are provided on both the liquid and vapor   sweat connections for ease of evacuating and charging.   • FACTORY TESTED - to verify system operation and con-   trol functioning before shipment.   FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE   036-21105-004 Rev. A (0902)   COOLING PERFORMANCE   AIR TEMP ON CONDENSER   95°F 115°F   MBH   SUCT.T/P @ COMPR.   MODEL   75 °F   125°F   TEMP   35   40   45   50   35   40   45   50   35   40   45   50   35   40   45   50   35   40   45   50   35   40   45   50   35   40   45   50   35   40   45   50   PSIG   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   61.5   68.5   76.0   84.0   MBH   13.0   14.5   16.1   17.7   18.7   20.8   22.9   25.2   21.9   24.3   26.7   29.3   27.6   30.4   33.3   36.3   33.6   37.3   40.9   44.8   46.7   51.7   56.8   62   KW   1.31   1.36   1.41   1.44   1.83   1.90   1.97   2.05   2.34   2.41   2.47   2.53   2.64   2.71   2.78   2.85   3.07   3.09   3.23   3.37   3.87   4.07   4.28   4.49   5.16   5.33   5.51   5.71   5.55   5.69   5.84   5.99   MBH   10.9   12.3   13.7   15.2   15.6   17.6   19.6   21.8   18.7   20.9   23.2   25.6   23.9   26.5   29.2   31.9   28.8   32.1   35.2   39.1   39.1   43.5   48   KW   1.41   1.49   1.54   1.58   1.99   2.07   2.17   2.27   2.54   2.63   2.73   2.82   2.88   2.99   3.08   3.18   3.43   3.48   3.69   3.85   4.82   5.08   5.34   5.6   KW   1.53   1.62   1.69   1.74   2.09   2.20   2.31   2.43   2.71   2.84   2.97   3.10   3.11   3.24   3.37   3.49   3.82   3.88   4.13   4.35   57.8   6.14   6.51   6.89   7.25   7.41   7.58   7.76   7.98   8.14   8.30   8.48   MBH   8.0   9.1   KW   1.59   1.69   1.76   1.82   2.13   2.24   2.37   2.49   2.77   2.91   3.06   3.20   3.20   3.34   3.48   3.62   4.01   4.08   4.36   4.60   6.39   6.83   7.28   7.73   7.92   8.08   8.25   8.43   8.82   8.98   9.15   9.32   9.0   10.2   11.3   12.4   12.5   14.3   16.2   18.3   15.6   17.6   19.7   21.9   20.2   22.5   25.0   27.5   24.0   26.9   30.2   33.3   31.9   35.7   39.6   43.7   43.4   47.5   51.8   56.1   58.3   64.3   70.5   76.9   H3DA012   H3DA018   H3DA024   H3DA030   H3DA036   H3DA048   H3DA060   10.1   11.1   10.9   12.6   14.5   16.5   14.0   15.9   18.0   20.0   18.3   20.5   22.8   25.5   21.6   24.3   27.5   30.4   28.3   31.8   35.4   39.2   40.8   44.7   48.7   52.9   54.4   60.2   66.2   72.4   52.7   48.7   53.1   57.8   62.5   66.2   72.5   79.1   86.1   53.8   58.9   64.1   69.6   73.9   80.7   87.7   95.1   6.09   6.25   6.43   6.61   6.60   6.75   6.91   7.07   H3DA076   NOTES:   1. For condensing unit only. Does not include effect of evaporator motor power or heat.   2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.   a. Increase capacity 1% for each 2° increase in sub-cooling.   b. Decrease capacity 1% for each 2° decrease in sub-cooling.   3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°F.   Maximum recommended condensing temperature is 140°F.   ACCESSORIES   SOUND RATINGS   Refer to Price Manual for specific model numbers.   Off Cycle Timer - Provides a 5 minute off cycle to prevent   rapid recycling of the compressor.   Room Thermostats - A wide selection of matching thermo-   stats is available to provide features required for any installa-   tion.   Start Assist Kit - Provides increased starting torque for   areas with low voltage conditions.   Compressor Blanket - Designed to further reduce the nor-   mal operating sounds of H3DA units.   H*DA   MODEL   SOUND RATING   DECIBELS   H3DA012   H3DA018   H3DA024   H3DA030   H3DA036   H3DA048   H3DA060   H3DA076   7.8   7.8   7.8   7.8   7.8   8.0   8.2   8.2   Unitary Products Group   3 036-21105-004 Rev. A (0902)   COOLING CAPACITY   AIR HANDLER   COOLING   NET MBH   COIL MODEL   RATED   CFM   UNIT MODEL   MODEL   SEER   (EER)   ELECTRIC HEAT KW   W KW   TOTAL   SENS.   1 & 3 PHASE HDA WITH N1AH AIR HANDLER & G2FD COILS   H3DA018S78   N1AHB12   N1AHB12   N1AHB12   2,5,7.5,10   17   G2FD024S17   G2FD024S17   G2FD030S17   G2FD030S17   G2FD036S17   G2FD036S17   G2FD046S17   G2FD048S21   G2FD048S24   G2FD060S24   G2FD060S24   650   800   20.4   23.5   24.0   30.0   30.2   34.2   - 14.9   17.1   17.5   21.9   22.0   24.9   - 2.23   3.07   2.79   3.32   3.35   4.05   - 9.60   8.90   9.00   9.70   9.70   9.00   - H3DA024S78   2,5,7.5,10   17   800   5,7.5,10,15,18   - 17   17   17   21   21   24   24   24   1025   1025   1200   1200   1550   1550   1550   1800   H3DA0308S78   H3DA036S50   N1AHB12   N1AHB12   5,7.5,10,15,18   N1AHC16   N1AHD20   N1AHD20   N1AHD20   5,7.5,10,15,20   7.5,10,15,20,25,30   7.5,10,15,20,25,30   7.5,10,15,20,25,30   46.2   46.2   47.8   60.0   34.7   34.7   35.9   43.9   5.06   5.06   5.16   6.45   9.90   9.90   9.90   9.40   H3DA048S50   H3DA060S50   1 & 3 PHASE HDA WITH F2RP SINGLE PIECE AIR HANDLERS   H3DA018S78   H3DA024S78   H3DA030S78   H3DA036S50   H3DA048S50   H3DA060S50   2,5,7.5,10   2,5,7.5,10   18   18   - - - - - - 650   850   16.9   21.0   28.0   35.3   42.9   54.1   12.5   15.5   20.8   23.8   31.7   24.5   2.0   2.5   3.2   4.2   5.3   6.4   - F2RP024   F2RP024   F2RP036   F2RP036   F2RP048   F2RP060   - 5,7.5,10,15,19   5,7.5,10,15,19   10,15,20,25   10,15,20,25   21.5   21.5   24   1090   1090   1490   1735   - 8.5   8.2   8.4   24   3 PHASE HDA WITH COMMERCIAL BELT DRIVE K*EU EVAPORATOR BLOWER UNIT   H3DA060S50   H3DA076S50   K2EU060   K5EU090   10,16,25   36   52   - - 2000   2550   55.5   74.6   39.5   53.7   6.30   7.61   10.00   9.80   10,16,26,36   MBH based on 80°F entering air temperature, 50% RH, and rated air flow.   KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.   SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided   by the total electric power input inwatt-hours during the same period.   (EER) = Energy Efficiency Ratio-steady state total BTUH/electric power input.   4 Unitary Products Group   036-21105-004 Rev. A (0902)   TYPICAL FIELD WIRING   POWER   WIRING   CONTROL   WIRING   GROUND   LUG   LOW VOLTAGE   JUNCTION BOX   ALL OUTDOOR WIRING MUST BE WEATHERPROOF.   USE COPPER CONDUCTORS ONLY.   TYPICAL FIELD WIRING - 1 PHASE   POWER WIRING   CONTROL WIRING   FACTORY WIRING   POWER WIRING   24 VOLT CONTROL WIRING   MINIMUM 18GA. WIRE   (NEC CLASS 2)   230-1-50   FURNACE OR AIR HANDLER TERMINAL BLOCK   Y R G W   C * TERMINAL W IS   ONLY REQUIRED   ON SYSTEMS   WITH HEAT.   CONTACTOR   TERMINALS   GND.   LUG   * COIL   Y R G W ROOM THERMOSTAT   CONDENSING UNIT   TYPICAL FIELD WIRING - 3 PHASE   POWER WIRING   380/415-3-50   POWER WIRING   CONTROL WIRING   FACTORY WIRING   24 VOLT CONTROL WIRING   MINIMUM 18GA. WIRE   (NEC CLASS 2)   FURNACE OR AIR HANDLER TERMINAL BLOCK   C Y R G W   TERMINAL W IS   ONLY REQUIRED   ON SYSTEMS   WITH HEAT.   * CONTACTOR   TERMINALS   GND.   LUG   * COIL   Y R G W ROOM THERMOSTAT   CONDENSING UNIT   Unitary Products Group   5 036-21105-004 Rev. A (0902)   TYPICAL INSTALLATION   THERMOSTAT   WEATHERPROOF   DISCONNECT   SWITCH   TO   POWER   SUPPLY   48” OVERHEAD   CLEARANCE   TO   INDOOR   BLOWER   NEC   CLASS 1   WIRING   12” REAR AND   SIDES   NEC   CLASS 2   WIRING   TO COIL   24” SERVICE ACCESS   CLEARANCE   NOTE: All outdoor wiring must be weatherproof   Seal opening(s) with permagum   or equivalent   MATCHING INDOOR COMPONENTS   ADD-ON COILS - FOR FURNACE APPLICATIONS   G2FD*   MULTI-POSITION   (UPFLOW, HORIZONTAL   AND DOWNFLOW)   AIR HANDLERS - FOR NON-FURNACE APPLICATIONS   N1AH   MODULAR BLOWER   (UPFLOW, HORIZONTAL   AND DOWNFLOW)   K*EU060,090   LIGHT COMMERCIAL   APPLICATIONS   F2RP   FAN COIL UNITS   (UPFLOW, HORIZONTAL)   G2FD   COIL   6 Unitary Products Group   036-21105-004 Rev. A (0902)   NOTES   Unitary Products Group   7 Subject to change without notice. Printed in U.S.A.   036-21105-004 Rev. A (0902)   Copyright © by York International Corp. 2002. All rights reserved.   Supersedes: 036-21105-003 Rev. C (0901)   Unitary   Product   Group   5005   York   Drive   Norman   OK   73069   |