Owner’s Guide
Xantrex
XC3012, XC5012,
XC1524 and XC2524
Battery Charger
12 V / 30 A
12 V / 50 A
24 V / 15 A
24 V / 25 A
Xantrex XC3012, XC5012,
XC1524 and XC2524
Battery Charger
Owner’s Guide
About Xantrex
Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with
products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells,
microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex
products include inverters, battery chargers, programmable power supplies, and variable speed drives
that convert, supply, control, clean, and distribute electrical power.
Trademarks
Xantrex XC3012, XC5012, XC1524 and XC2524 Battery Charger is a trademark of Xantrex
International. Xantrex is a registered trademark of Xantrex International.
Other trademarks, registered trademarks, and product names are the property of their respective owners
and are used herein for identification purposes only.
Notice of Copyright
Xantrex XC3012, XC5012, XC1524 and XC2524 Battery Charger Owner’s Guide© August 2005
Xantrex International. All rights reserved.
Disclaimer
UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC.
(“XANTREX”)
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF
ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER
DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER
DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF
THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE
ENTIRELY AT THE USER’S RISK.
Date and Revision
August 2005 Revision B
Part Number
975-0187-01-01
Contact Information
Phone: 1 800 670 0707 (toll free North America)
+34 93 470 5330 (Europe)
1 360 925 5097 (direct and rest of world)
Fax:
1-800 994 7828 (toll free North America)
+34 93 473 6093 (Europe)
1 360 925 5143 (direct and rest of world)
[email protected] (Europe)
[email protected] (rest of world)
About This Guide
Purpose
The purpose of this Owner’s Guide is to provide explanations and procedures for
installing, operating, maintaining, and troubleshooting the Xantrex XC3012,
XC5012, XC1524 and XC2524 Battery Charger.
Scope
The Guide provides safety guidelines, detailed planning and setup information,
procedures for installing the charger, as well as information about operating and
troubleshooting the unit. It does not provide details about particular brands of
batteries. Consult individual battery manufacturers for this information.
Audience
The Guide is intended for anyone who needs to install and operate the Xantrex
XC3012, XC5012, XC1524 and XC2524 Battery Charger. Installers should be
certified technicians or electricians.
Organization
This Guide is organized into 4 chapters and 1 appendix:
Chapter 1, “Introduction”: Chapter 1 describes the XC Series standard features. It
also provides information to prepare for installation of the XC Series.
Chapter 2, “Installation”: Chapter 2 provides procedures for installing, testing and
configuring the XC Series.
Chapter 3, “Operation”: Chapter 3 describes the operating states and provides
procedures for charging a battery and performing an equalization.
Chapter 4, “Troubleshooting”: Chapter 4 contains information on error codes and
procedures for troubleshooting your XC Series charger.
Appendix A, “Specifications”: Appendix A details the specifications for the
XC Series.
iii
About This Guide
Conventions Used
The following conventions are used in this guide.
WARNING
Warnings identify conditions or practices that could result in personal injury or loss of life
CAUTION
Cautions identify conditions or practices that could result in damage to the unit or other
equipment.
Important: These notes describe things which are important for you to know, but not as
serious as a caution or warning.
This Guide contains information for four versions of the XC Series.
The Xantrex XC3012 Battery Charger (12 V, 30 A) will be referred to as the
XC3012 when it is being referenced individually.
The Xantrex XC5012 Battery Charger (12 V, 50 A) will be referred to as the
XC5012 when it is being referenced individually.
The Xantrex XC1524 Battery Charger (24 V, 15 A) will be referred to as the
XC1524 when it is being referenced individually.
The Xantrex XC2524 Battery Charger (24 V, 25 A) will be referred to as the
XC2524 when it is being referenced individually.
When the Xantrex XC3012, XC5012, XC1524 and XC2524 Battery Chargers are
being referenced together, they will be referred to as the XC Series.
Related Information
You can find more information about Xantrex Technology Inc. as well as its
products and services at www.xantrex.com
iv
975-0187-01-01
Important Safety Instructions
WARNING
This chapter contains important safety and operating instructions as prescribed by safety
standards for chargers used in RV and marine applications. Read and keep this Owner’s
Guide for future reference.
1. Before installing or using the Xantrex XC3012, XC5012, XC1524 or XC2524
Battery Charger (XC Series), read all instructions and cautionary markings on
the XC Series, the batteries, and all appropriate sections of this guide.
2. Do not expose the XC Series to rain, snow, spray, or bilge water. To reduce risk
of fire hazard, do not cover or obstruct the ventilation openings. Do not install
the XC Series in a zero-clearance compartment. Overheating may result.
3. Use only attachments recommended or sold by Xantrex. Doing otherwise may
result in a risk of fire, electric shock, or injury to persons.
4. The XC Series is designed to be permanently connected to the AC and DC
electrical systems. Xantrex recommends that all wiring be done by a certified
technician or electrician to ensure compliance with the local and national
electrical codes relevant to your installation. It is the responsibility of the
installer to ensure that the installation of the XC Series complies with all
relevant electrical codes.
5. To avoid a risk of fire and electric shock, make sure that existing wiring is in
good condition and that wire is not undersized. Do not operate the XC Series
with damaged or substandard wiring.
6. Do not disassemble the XC Series. It contains no user-serviceable parts.
Attempting to service the XC Series yourself may result in a risk of electrical
shock or fire.
NOTE: Disassembling the XC Series will void your warranty.
7. To reduce the risk of electrical shock, disconnect both AC and DC power from
the XC Series before attempting any maintenance or cleaning or before
working on any circuits connected to the XC Series. Turning the XC Series off
using the remote display will not reduce this risk.
v
Safety
8. The XC Series is provided with an AC ground conductor that must be
connected to the AC input ground and a DC ground stud which must be
connected to the DC system ground.
9. For marine applications in the United States, external connections to the
charger shall comply with the United States Coast Guard Electrical Regulations
(33CFR183, Sub part 1).
Explosive Gas and Battery Precautions
WARNING: Explosion or fire hazard
1. Read this guide and follow the instructions exactly before installing or using
your XC Series.
2. Follow all instructions published by the battery manufacturer and the
manufacturer of the equipment in which the battery is installed.
3. Working in the vicinity of lead-acid batteries is dangerous. Batteries generate
explosive gases during normal operation.
4. The XC Series has been approved as Ignition Protected. It may be installed in
areas containing gasoline tanks and fittings which require Ignition Protected
equipment. Xantrex recommends, nevertheless, that it is safest not to install
electrical equipment in these areas.
5. Make sure the area around the battery is well ventilated.
6. Never smoke or allow a spark or flame near the engine or batteries.
7. Use caution to reduce the risk of dropping a metal tool on the battery. It could
spark or short circuit the battery or other electrical parts and could cause an
explosion.
8. Remove all metal items, like rings, bracelets, and watches when working with
lead-acid batteries. Lead-acid batteries produce a short circuit current high
enough to weld metal, causing a severe skin burn.
9. Have someone within range of your voice or close enough to come to your aid
when you work near a lead-acid battery.
vi
975-0187-01-01
Safety
10. Have plenty of fresh water and soap nearby in case battery acid contacts skin,
clothing, or eyes.
11. Wear complete eye protection and clothing protection. Avoid touching your
eyes while working near batteries.
12. If battery acid contacts skin or clothing, wash immediately with soap and water.
If acid enters your eye, immediately flood it with running cold water for at least
twenty minutes and get medical attention immediately.
13. If you need to remove a battery, always remove the ground terminal from the
battery first. Make sure all accessories are off to reduce the possibility of
causing a spark.
FCC Information
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
975-0187-01-01
vii
viii
Contents
Important Safety Instructions
Explosive Gas and Battery Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vi
FCC Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -vii
1
Introduction
Xantrex XC3012, XC5012, XC1524 and XC2524 Battery Charger Features - - - - - - 1–2
XC Series Appearance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–3
Information Centers of the XC Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–4
Remote Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–4
Onboard Status Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–6
Rear Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–7
Preparing for Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–8
Tools and Materials - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–9
Location - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–10
Wiring Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–12
DC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–12
AC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–13
Battery Bank Size Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–14
2
Installation
Installing the XC Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2
Installation Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2
Pre-Installing DC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–3
Pre-Installing AC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–4
Mounting the Remote Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–7
Mounting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–8
Grounding - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–9
Final Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–10
Final DC Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–11
Final AC Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–12
Powering Up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–12
975-0187-01-01
ix
Contents
Installing Optional Accessories- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–13
Battery Temperature Sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–13
Drip Protection Rubber Boots - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–14
Configuring the XC Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–15
3
Operation
About Charging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–2
Multiplex 3-Stage Charging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–2
Sequential 2-Stage Charging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–3
Charging Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–3
Charging Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–6
Equalizing Flooded Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–8
Transitioning the XC Series to On, Disabled or Off - - - - - - - - - - - - - - - - - - - - - - 3–10
Accessing Charger Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–11
Reading Remote Display and Onboard Status Indicator Lights - - - - - - - - - - - 3–11
Reporting While Charging or Equalizing - - - - - - - - - - - - - - - - - - - - - - - - - - 3–13
Reporting While Battery Monitoring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–14
Reporting While Disabled - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–14
Using A Generator As Source Power - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–15
4
Troubleshooting
Care and Maintenance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–2
Indicator Light Flashing Sequences- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–3
Error Messages on Remote Display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–4
Problem Solving - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–7
A
Specifications
Physical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–2
Electrical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–2
AC Input Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–3
Temperature Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–4
Protection Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–4
Approvals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A–5
Warranty and Product Information - - - - - - - - - - - - - - - - - - - - - - - - - - WA–1
x
975-0187-01-01
Introduction
1
Chapter 1 describes the XC Series standard features. It
also provides information to prepare for installation of
the XC Series.
Introduction
Xantrex XC3012, XC5012, XC1524 and XC2524 Battery
Charger Features
The XC Series provides the following standard features:
•
three full current rated, independently controlled outputs which enable it to
charge three different batteries or battery banks. Each bank can be of a different
battery type, stage of charging, and temperature compensation
•
one battery temperature sensor (BTS) is included. Optional BTSs may be
purchased for the other two outputs, to provide complete optimal battery
charging to each battery or bank
•
•
battery monitoring functions while in float mode or rest mode
correct charging voltage for your batteries when connected to almost any single
phase AC power outlet in the world
•
invertable remote display panel which can also be removed from the charger
and mounted up to 20 m (65 ft) away for remote control and monitoring
The XC Series provides the following protection features:
•
true “fuseless” reverse polarity protection to guard against continuous reverse
battery polarity without charger damage
•
•
•
AC over voltage protection shutdown
over temperature protection shutdown
electronic current limiting for protection against short circuit on the unit’s
output
•
built-in protection against accidental connection to a higher battery voltage, up
to 24 VDC
•
•
•
•
battery temperature compensation to 0 °C (32 °F) (with BTS installed)
ignition protected rating, enabling installation in engine spaces
isolated design to reduce shock hazard
automatic charge resumption after AC power interruption
1–2
975-0187-01-01
XC Series Appearance
XC Series Appearance
This section describes the parts of the XC Series. Figure 1-2 shows the XC Series.
2
1
3
Figure 1-1 XC Series
Item
Description
1
2
Remote display for all programming functions and monitoring of the XC Series.
Onboard status panel for monitoring charger status and charging current at the
XC Series when the remote display is mounted remotely from the charger.
3
Mounting flanges
975-0187-01-01
1–3
Introduction
Information Centers of the XC Series
Remote Display
This section describes the parts of the remote display of the XC Series. The remote
display can be rotated 180°, or it can be removed and remotely mounted up to 20 m
(65 ft) from the XC Series for convenience. Figure 1-2 shows the remote display.
A “press and hold” action on the remote display means that the button must be held
down for more than 2 seconds in order to send the instruction. A “press” action on
the remote display means that the button must be pressed and released before 2
seconds have elapsed.
2
3
4
5
6
1
7
Figure 1-2 XC Series Remote Display
Item Description
1
ON/STANDBY push button
•
•
•
Press to turn on or disable the charger while AC power is connected
Press and hold to apply selection when in setup or equalization mode
Press to show battery bank voltages when AC is disconnected
2
Battery bank indicator lights
•
•
Illuminate to show which bank has been selected for setup or status display
Illuminate during a fault or warning to show which bank has the fault or warning, or
illuminate all three if the charger itself has the fault or warning
1–4
975-0187-01-01
Information Centers of the XC Series
Item Description
3
Alpha-numeric display shows
•
•
•
•
•
Configuration
Fault or warning messages (see Table 4-2 on page 4–4)
Battery bank voltage and current
Type of charging (2 stage or 3 stage)
State of charge
4
5
Units indicator lights
Illuminate to show unit of measure for the numeric read-out on the alpha-numeric display
•
BANK selection push button
•
•
Press to select a bank during setup
Press at the same time as MODE to enter or exit equalization mode.
6
7
TYPE selection push button
Press to select flooded (lead acid), gel, AGM, or lead calcium batteries.
•
MODE selection push button
•
•
•
Press to select charging state during setup: 2 stage or 3 stage.
Press at the same time as BANK to enter or exit equalization mode.
Press and hold to enter setup.
The indicator lights and display are also used to indicate error codes. See Chapter 4,
“Troubleshooting” for a list of faults and how to clear them.
975-0187-01-01
1–5
Introduction
Onboard Status Panel
This section describes the parts of the onboard status panel of the XC Series.
Figure 1-3 shows the panel.
2
3
4
1
Figure 1-3 XC Series Onboard Status Panel
Item Description
1
Charge Current
•
•
•
•
Displays the output charge current in % of charger maximum for the bank being charged
100% indicator light flashes to indicate battery temperature too high (> 50 °C, 122 °F)
10% indicator light flashes to indicate battery temperature too low (< 0 °C, 32 °F)
25% indicator light flashes to indicate that a battery has been disqualified (see page 3–4)
2
3
4
Charger Status - READY
•
Ready indicator light illuminated indicates all batteries are fully charged, and are now in
float or rest
Charger Status - CHARGING
•
•
Charging indicator light illuminated indicates unit is performing a normal charge cycle
Charging indicator light flashing indicates that the unit is performing an equalization cycle
Charger Status - FAULT
•
Fault indicator light continuously illuminated indicates any fault condition that prevents
the XC Series from charging one or more batteries, but is not a charger failure - remote
display shows details of fault
•
Fault indicator light flashing indicates the XC Series has experienced a charger failure -
remote display shows
followed by
1–6
975-0187-01-01
Rear Panel
Rear Panel
This section describes the parts of the rear panel of the XC Series. Figure 1-4 shows
the rear panel.
9
7
8
11
2
+ +
3
4
1
10
5
6
Figure 1-4 XC Series Rear Panel
Item
1
Description
Remote display communication connector
2
BTS1 (battery temperature sensor for bank 1) connector
BTS2 (battery temperature sensor for bank 2) connector
BTS3 (battery temperature sensor for bank 3) connector
Battery negative, common for all 3 banks (6 mm stud)
Battery positive for bank 1 (6 mm stud)
Battery positive for bank 2 (6 mm stud)
Battery positive for bank 3 (6 mm stud)
Fan assembly
3
4
5
6
7
8
9
10
11
Chassis ground (earth) for DC wiring
AC wiring access panel
975-0187-01-01
1–7
Introduction
Preparing for Installation
The XC Series is designed to be permanently mounted. Figure 1-1 shows a typical
installation with three batteries, a BTS and a remote display. It also shows the AC
and DC wiring and protection devices required for a successful installation.
9
L
N
G
8
3
2
1
7
5
5
5
6
10
4
6
6
4
4
Figure 1-5 XC Series System
1
AC mains source with correct size and type of circuit breaker
AC input wiring compartment
2
3
DC negative cable
4
DC positive cables
5
DC circuit breaker or DC fuse and disconnect
Battery or battery bank
6
7
Engine ground bus or DC negative bus
Remote display panel
8
9
Battery temperature sensor (#1 is standard equipment. #2 and #3 are optional)
DC chassis ground (earth)
10
1–8
975-0187-01-01
Preparing for Installation
Tools and Materials
To mount and connect the XC Series you need the following tools:
•
•
•
•
•
•
10 mm wrench or socket for the DC terminals and ground stud
Phillips screwdriver for securing the AC wiring compartment cover
power drill
drill bit for pilot holes for mounting screws
wire stripper
manufacturer's recommended crimp tool for any crimp terminals that are being
used
You need the following materials:
•
3 conductor AC input wiring
Use the information in “AC Wiring” on page 1–13 and your local electrical
codes to determine the correct wire and breaker or fuse.
•
•
AC cable strain relief (if the one included is not sufficient for your local
electrical code requirements)
appropriately sized DC cables for each battery, with suitable connectors at the
battery end
•
•
•
•
•
appropriately sized DC chassis ground (earth) with suitable connectors
ring terminals to fit 6 mm (1/4 in.) studs at the charger end
DC fuse and disconnect or circuit breaker for each battery bank
mounting hardware, 3 mm (#6) corrosion resistant 6 pieces.
other means to route and secure AC and DC wiring
975-0187-01-01
1–9
Introduction
Location
Install the XC Series in a location that meets the following requirements:
Condition Requirement
Dry
The XC Series must be installed in a dry location not subject to rain, spray or splashing
bilge water.
Clean
Cool
The XC Series should not be exposed to metal filings or any other form of conductive
contamination.
The ambient air temperature should be between 0 °C - 50 °C (32 °F - 122 °F) for best
performance.
Ventilated There must be at least 76 mm (3 in.) of clearance on each end of the XC Series for air
flow. Ventilation openings on the unit must not be obstructed. If mounting in a tight
fitting compartment, the compartment must be ventilated with cut-outs to prevent
overheating.
Safe
This battery charger is ignition protected, so it can be installed in areas containing
gasoline tanks or fittings which usually require ignition protected equipment. Xantrex
recommends, however, that it is safest not to install electrical equipment in these areas.
Close to
batteries
The XC Series should be installed as close as possible to the batteries, but not in the
same compartment to prevent excess corrosion. Avoid excessive cable lengths and use
the recommended wire sizes. Xantrex recommends <3% wire voltage drop (round
circuit) on battery cables under full load.
When planning where and how to mount the XC Series, be sure the installation
allows the charger to be mounted in one of the permitted vertical or horizontal
orientations.
For marine installations, only the mounting configurations with a check mark in
Figure 1-6 meet the North American and European marine requirements. Marine
products are required to meet drip tests, to ensure safety in the presence of
condensation. If you are certain your installation is not subject to moisture,
configuration d) in Figure 1-6 may be used.
1–10
975-0187-01-01
Preparing for Installation
a)
c)
b)
Vertical - this configuration is unsafe and
should not be used
Vertical
d)
Vertical - this configuration may be used
in an environment which is dry and clean
only (non-marine)
Horizontal
Figure 1-6 XC Series Mounting Orientations
975-0187-01-01
1–11
Introduction
Wiring Requirements
WARNING
Wire and fuse sizes are dictated by electrical standards. Different standards apply in
different countries and different types of installations, for example, boat, home or RV. It is
the responsibility of the installer to ensure that the installation complies with all applicable
standards.
CAUTION
Ensure that both wires and fuses are correctly sized.
Maximum continuous current available from the charger may be an additional 6–10% above
the nominal current rating of the charger. Output current may also vary depending on
ambient temperature conditions.
DC Wiring
The following two tables show some typical wire sizes, based on 3% voltage drop
(round circuit), 75 °C (167 °F) rated wire and wiring being inside the engine
compartment – assumed ambient of 50 °C (122 °F).
Table 1-1 DC Wiring Requirements
Wire Length
(maximum length one way)
Wire Size (AWG and mm2)
feet
meters
1.5
XC3012
XC5012
XC2524
XC1524
5
No. 10
5 mm2
No. 6
13 mm2
No. 10
5 mm2
No. 12
3 mm2
7.5
20
2.25
6
No. 8
No. 6
No. 10
5 mm2
No. 12
3 mm2
8 mm2
13 mm2
No. 6
13 mm2
No. 4
19 mm2
No. 10
5 mm2
No. 12
3 mm2
1–12
975-0187-01-01
Preparing for Installation
Over-current protection disconnect
The DC circuit from the battery to the charger must be equipped with a disconnect
and over-current protection device. The device usually consists of a DC-rated
circuit breaker, a “fused disconnect”, or a separate fuse and disconnect. These
devices must be rated for DC voltage and current. Do not substitute devices rated
only for AC voltage; they may not operate properly.
The current rating of the DC fuses must be matched to the size of the DC wiring
used, in accordance with the applicable codes.
The DC chassis ground (earth) should not be more than one size smaller than the
DC wiring size selected (see Table 1-1). Refer to your local electrical codes for
verification.
AC Wiring
The AC wiring must meet the following requirements before you install the
XC Series:
The AC input wiring for the XC Series should be three-conductor cable, providing a
line, neutral, and ground conductor (or L1, N, GND) in an outer jacket.
For example, in North America for 120 VAC use a 14 AWG wire with a 15 A
breaker; or typically in Europe for 230 VAC use either a 2.5mm2 wire with a 16 A,
double pole breaker or fuse or use 1.5 mm2 wire with a 10 A, double pole breaker or
fuse. Note that every jurisdiction will have different requirements, so see the
regulations for your local jurisdiction to determine which wire size and type is
correct. A second example:
•
for marine applications the United States ABYC requires stranded wire, which
is more robust than solid wire when exposed to vibration
•
for RV applications, the United States NEC allows solid wire in multi-
conductor cable, but stranded wire will withstand vibration better.
The circuit supplying the XC Series must be protected by the correct size and type
of breaker to meet the code for your local jurisdiction and application. If a fuse is
used, a disconnect switch is needed ahead of the fuse.
975-0187-01-01
1–13
Introduction
Battery Bank Size Requirements
The XC Series is designed to work with a minimum battery bank size. Each bank
should meet the minimum Ah rating shown in Table 1-2.
Table 1-2 Minimum Battery Bank Size
Models
XC 1524
XC 2524
XC 3012
XC 5012
30
50
60
100
Minimum Battery
Bank Size (Ah)
1–14
975-0187-01-01
Installation
2
Chapter 2 provides procedures for installing, testing
and configuring the XC Series.
The unit is packed with the following materials:
•
•
•
•
•
•
•
•
Owner’s Guide
AC cable strain relief
Two DC cable boots
Blank plate for remote display cavity
One battery temperature sensor (BTS)
Five #6 lockwashers
Five #6 flatwashers
Five #6 nuts
After unpacking the unit, record the serial number and
other purchase information on page WA–4 of this
guide.
Installation
Installing the XC Series
WARNING: Shock and Energy Hazards
Be sure to read the safety guidelines and pay attention to all cautions and warnings
throughout the installation procedure. The installer is responsible for ensuring compliance
with the installation codes for your particular application.
Disconnect all sources of AC and DC power before proceeding.
Installation Sequence
To make charger installation quick and easy, Xantrex recommends that the
installation tasks be performed in the following sequence:
1. Select charger mounting position and plan AC and DC cable routing (page 1–8)
2. Install DC cable runs and fuses or breakers (page 2–3)
3. Make the AC connections at the charger (page 2–4)
4. Mount the remote display and charger in position (page 2–7)
5. Make the final DC and then AC cable connections (including earth grounds)
(page 2–10)
2–2
975-0187-01-01
Installing the XC Series
Pre-Installing DC Wiring
The procedure for installing the DC wiring applies to a single battery or multiple
batteries or battery banks.
WARNING: Shock or arc burn hazard
To help prevent accidental shorts or sparks, leave the DC disconnects or breakers in the Off
position or fuses removed from their fuse holders until installation is complete.
Important: Xantrex recommends that you install the rubber boots over the XC Series DC
terminals to provide drip protection and increased protection from short circuits. You need
to install the boots before doing any other DC wiring. See “To install rubber boots:” on
page 2–14.
To install DC wiring:
1. Identify the battery or bank that most frequently becomes deeply discharged.
This bank will often be a deep cycle battery referred to as the House Bank on a
boat, as opposed to an engine Start Battery. This high priority bank should be
connected to bank 1 on the XC Series, which is the default bank.
2. Plan the route that the DC wires will follow, keeping it as short as possible.
Measure and cut the required wire length. Allow some extra length for
connections and to provide slack in the wires.
Note: The connection to the battery negative circuit may not be at a battery, but
may be at an engine negative bus or a DC negative bus. If in doubt, consult the
boat schematics.
3. Identify the positive wires, by using color-coded wire or by marking both ends
of the wire with colored tape or similar kind of marking. Repeat with a different
color for the negative. Most installation codes recommend coloring the positive
red and the negative black.
Important: You may find it helpful to label each cable, associating it with the battery
bank it is connected to. For example, bank 1 (–), bank 1 (+), bank 2 (–).
4. Install a DC circuit breaker or fuse/disconnect in each positive cable close to
each battery. For your applications and jurisdiction, consult your local electrical
codes regarding the distance between the battery and the disconnect device. Be
sure the breaker is open or fuse is not inserted at this time.
975-0187-01-01
2–3
Installation
5. Route the wiring to the batteries and to the XC Series, but don’t connect it yet.
Avoid routing wiring through an electrical distribution panel, battery isolator, or
other device that will add voltage drops.
6. Install crimp lugs on each end of the battery cables using the crimp
manufacturer’s instructions and tool.
7. Install rubber boots over the charger end of the DC cables.
Xantrex recommends that you install rubber boots over the XC Series DC
terminals to provide drip protection. Follow the procedure on page 2–14 to
install rubber boots.
8. Route the battery temperature sensor from each battery to the charger location.
9. Proceed to “Pre-Installing AC Wiring”.
Pre-Installing AC Wiring
Before connecting AC wiring, make sure the AC source circuit is protected by a
breaker switch of the correct size and type, to comply with the electrical code for
your location and application.
To install AC wiring:
1. Disconnect the AC source by turning off the breaker feeding the circuit,
unplugging from shorepower and disconnecting any other power sources (such
as a generator).
2. Plan the route that the AC wiring will follow from the source (usually an AC
distribution panel) to the XC Series. Measure and cut the required length of
three-conductor cable.
For example, in North America for 120 VAC use a 14 AWG wire with a 15 A
breaker; or typically in Europe for 230 VAC use either a 2.5mm2 wire with a
16 A, double pole breaker or fuse or use 1.5 mm2 wire with a 10 A, double pole
breaker or fuse. Note that every jurisdiction will have different requirements, so
see the regulations for your local jurisdiction to determine which wire size and
type is correct.
Allow some extra length for connections and to provide slack.
3. Make the AC connections to the back of the charger when it is sitting on a table
or other convenient work surface.
Route the AC cables to the source after the charger is mounted in position.
4. Unscrew the wiring compartment cover from the left rear of the XC Series to
expose the AC wiring access hole.
2–4
975-0187-01-01
Installing the XC Series
5. Install the cable strain relief on the XC Series end of the source AC cable.
6. Carefully remove 50 – 75 mm (2 – 3 in.) of the outer jacket, being careful not to
cut or nick the insulation on the individual conductors.
7. Pull the XC Series pigtail wires out through the access hole.
8. Thread the source AC cable through the knockout beneath the wiring
compartment cover and then pull it out through the access hole.
9. Connect the AC wiring to the XC Series pigtail wires, being sure to connect the
line conductor to the line, the neutral to the neutral, and the ground to the
ground. The pigtail wires are color coded as follows:
Conductor
Line
Color code
Black or brown
White or blue
Neutral
Ground
Green with yellow stripe
10. Make the connections with twist-on or crimp-on connectors or with other
approved connectors suitable for your installation. For example, the ABYC
Standards and Recommended Practices for Small Craft prohibit twist-on
connectors for AC connections on a boat. For non-marine installations in
locations not subject to vibration, either type of connector may be used.
For marine installations, follow the procedure for installing butt splice
connectors.
975-0187-01-01
2–5
Installation
To connect AC wires with the crimp-on butt-splice connector:
Important: You must exercise care when crimping butt-splice connectors. Use the
crimp tool recommended by the manufacturer for the connector used.
a) Using a wire stripper, carefully strip 8 mm (5/16 in.) from the ends of the
two wires being connected.
b) Insert one wire into one end of the butt-splice, until the insulation hits the
internal metal crimp section, insert the butt-splice into the crimping tool,
and crimp firmly. The proper location for the crimp is approximately
1.6 mm (1/16 in.) past where the butt-splice insulation tapers down as
shown.
1/16 “
CRIMP TOOL
STRIP 5/16”
c) Repeat Step b for the other end of the butt-splice.
11. Push the AC cable strain relief into the electrical junction box hole until it snaps
into place.
12. When all connections are completed, push the wiring and connectors inside the
wiring compartment. Install the wiring compartment cover and fasten with the
supplied blunt-tip screws and lockwashers.
2
1
13. Proceed to “Mounting the Remote Display”.
2–6
975-0187-01-01
Installing the XC Series
Mounting the Remote Display
WARNING: Shock hazard
Even if you intend to leave the remote display in the shipped orientation in the XC Series,
you must remove the remote display and secure it in place by removing the non-stick
backing on the rear and pressing the remote display flanges in place. If you do not use the
non-stick backing, the XC Series will not be drip protected.
To accommodate the charger mounting orientation, the remote display can be
removed and turned 180 ° for readability. If you intend to mount the display
remotely, up to 20 m (65 ft), remove the display before mounting the charger and
secure the blank plate to cover the display socket on the unit.
CAUTION
Ensure you are placing the display in the correct orientation before removing the adhesive
backing. The adhesive tape for attaching the remote is extremely strong and you may be
unable to remove it without damaging the display or other equipment.
To remove the display:
1. Unplug the display cable from the telephone-type connector on the back of the
unit.
2. Release the display cable from the retaining clips on the underside of the unit.
3. Remove the remote display from the charger and read and then remove the
warning label that is attached to it.
To secure the display or blank plate on the unit:
1. Choose the display orientation that is appropriate for the charger orientation.
2. Remove the adhesive backing on the back of the display or blank plate .
3. Line up the display or blank plate with the display socket, making sure it is in
the chosen orientation.
4. Firmly press the flanges in place. Do not press in the middle of the display.
5. Route the display’s North American style telephone-type cable under the unit
and plug the cable into the bottom connector on the rear panel of the unit.
975-0187-01-01
2–7
Installation
To remotely mount the display:
1. Remove the display as described on page 2–7.
2. Secure the blank plate in the display socket as described.
3. Ensure that the extension cable used for the remote display is long enough to
suit the installation. A standard North American style, 4 conductor (RJ-11)
telephone cable extender is adequate.
4. Use the enclosed mounting template to cut a hole for the display in the chosen
mounting surface.
Take care that there is nothing behind the surface for you to damage.
5. Feed the remote display extension cable through the hole and route it to the
charger. Be careful not to damage the telephone connector locking tab when
routing the cable. You can use some tape to protect the locking tab from
catching on something and breaking off when routing the cable.
6. Remove the adhesive backing on the back of the display.
7. Line up the display with the mounting hole.
8. Firmly press the flanges in place. Do not press in the middle of the display.
9. Once the XC Series is mounted, plug the cable into the bottom connector on the
rear panel of the XC Series.
10. Proceed to “Mounting”.
Mounting
Mount the XC Series using the mounting slots provided.
For marine installations, only the mounting configurations with a check mark in
Figure 1-6 on page 1–11 meet the North American and European requirements.
This is to ensure that any moisture that may be present will not enter the XC Series.
Important: Be sure to measure your AC and DC cables and plan the routing of the cables
before drilling the pilot holes for mounting the XC Series.
To mount the XC Series:
1. Keep the carton and packing material in case you need to return the XC Series
for servicing.
2. Ensure that you have selected a mounting surface that is clear, flat and allows
for a minimum of 76 mm (3 in.) of clearance on each end for fan circulation.
2–8
975-0187-01-01
Installing the XC Series
3. Secure the enclosed mounting template to the mounting surface with tape.
4. Drill the six pilot holes for the mounting screws, taking care that there is
nothing behind the surface that can be damaged by the drill.
5. Mount the XC Series using corrosion resistant, #6 (3 mm) round, pan head (or
similar) screws.
The top two keyhole-style mounting holes can be used to hold the XC Series in
place while fastening the bottom four screws. For secure, permanent mounting,
use all six mounting slots.
Grounding
WARNING: Electric shock hazard
Do not make an ungrounded installation. Have an electrician install a properly grounded
circuit if one is not available. Improper connection can result in risk of an electric shock.
The XC Series Battery Charger must be grounded to reduce the risk of electrical
shock. The AC input ground wire of the charger must be properly connected to
ground in accordance with the applicable electrical codes, this is usually a ground
terminal in the AC distribution panel where the branch circuit originates.
Xantrex recommends that you install a DC chassis ground (earth) from the ground
stud on the XC Series to the engine negative bus or DC ground bus. The DC chassis
ground (earth) should not be more than one size smaller than the power conductors,
and must be rated for the battery fuses that are used to protect the DC wiring. Refer
to your local electrical codes to verify if this is required in your jurisdiction or in
your application.
Proceed to “Final Connections”.
975-0187-01-01
2–9
Installation
Final Connections
Once the DC cables, AC cables and XC Series are all in place the final connection
may be made.
Figure 2-1 shows the connection order.
4
3 2 1
14
8
15
5
10
9
11
13
6
7
12
Figure 2-1 DC Wiring Connection Order
2–10
975-0187-01-01
Installing the XC Series
Final DC Connections
WARNING: Shock hazard
Make sure that the DC fuse or circuit breaker is still open.
To make the last DC connections:
1. Connect the negative cable from the negative terminal on the battery (if you are
using only one battery or bank), or the negative ground bar or bus (if you are
using more than one battery or bank), to the negative DC terminal on the
XC Series (Figure 2-1). Use a flatwasher, a lockwasher and a nut (5 included in
the installation kit) to secure the connection.
Tighten the nuts to 3 N-m (30 lb-in.) torque and test that the wire is secure.
2. Connect each positive cable to the correct positive DC terminal on the
XC Series (Figure 2-1). Use a flatwasher, a lockwasher and a nut (5 included in
the installation kit) to secure the connection.
Tighten the nuts to 3 N-m (30 lb-in.) torque and test that the wire is secure.
3. Connect the free end of each positive cable to the correct positive terminal of
the battery, using sufficient torque as recommended by your battery
manufacturer.
4. Connect the free end of the negative cable to the negative terminal on the
battery, using sufficient torque as recommended by your battery manufacturer.
Note: If you are using more than one battery, you will need to connect the
negative cable from each of the batteries to the negative ground bar or bus. The
negative ground bar or bus will then have a single negative cable connecting to
the negative charger terminal.
5. Before proceeding, carefully check the wiring polarity – make sure the positive
terminals of the XC Series are connected to the correct terminals of the battery
(fuses or breakers) and from there to the positive terminals of the battery. Make
sure the negative terminal of the XC Series is connected to the battery negative
terminal (or engine negative bus/DC negative bus). Do not reverse the
connections.
6. Install the DC chassis ground (earth) from the ground stud on the XC Series to
the engine negative bus or DC ground bus.
7. Connect the BTS cable and the remote display cable to the rear of the charger.
975-0187-01-01
2–11
Installation
8. Secure cables in place using tie-wraps, P-clamps or cable straps according to
electrical codes. Coil and tie any extra BTS or remote display extension cable.
9. The DC breakers may be closed or fuses inserted at this time.
Final AC Connections
To make the last AC connections:
1. Complete the installation by routing the AC cable to the AC source.
2. Connect the AC cable to the AC disconnect breaker and ground in accordance
with the color codes on page 2–5.
3. Secure cables in place using tie-wraps, P-clamps or cable straps according to
electrical codes.
Powering Up
Make one last check that all connections and connectors are secure.
The XC Series charger may now be powered up. Switch the AC power on at the
source breaker. It is normal to see a 7-10 second delay while the unit powers up.
During this time, the indicator lights on the onboard status panel and the remote
display will not display any information.
At very low AC source voltages (for example, less than 105 VAC) the start up time
will increase proportionally up to as much as 40 seconds.
2–12
975-0187-01-01
Installing Optional Accessories
Installing Optional Accessories
The XC Series ships with a battery temperature sensor (BTS) and drip protection
rubber boots for the DC cables.
Battery Temperature Sensor
Xantrex strongly recommends that you install a Battery Temperature Sensor (BTS)
to protect your battery and improve charging accuracy. It is best to use a separate
BTS with each individual battery bank, to provide optimal charging and protection
of each bank. If no BTS is connected, the charger defaults to the charging
conditions for 40 °C (104 °F). At this temperature the charging voltage is lower to
keep batteries from overcharging; charging will be slower and the batteries will be
slightly undercharged.
One BTS is provided with with your XC Series and additional battery temperature
sensors may be purchased separately.
To install a BTS:
1. Switch off all devices operating from the battery.
2. Connect the ring terminal on the sensor directly on to the negative battery stud,
or affix the double-sided adhesive backing (included) to the sensor back and
attach the sensor to the side of the battery to be monitored.
3. Route the sensor cable to the charger and plug it into the bank 1 (default if using
only one BTS), bank 2 or bank 3 connector on the rear panel.
975-0187-01-01
2–13
Installation
Drip Protection Rubber Boots
Xantrex recommends that you install the supplied rubber boots over the XC Series
DC terminals to provide drip protection.
To install rubber boots:
1. Before making the DC connections to the charger, feed the rubber boot over the
charger end of the DC cables.
2. Perform all other DC connections as described in “To install DC wiring:” on
page 2–3.
3. After the DC cables are connected to the charger, slide the boot up the cables
and over the DC terminals. If you are only using one battery, slide the spare
boots over the unused DC terminals.
2–14
975-0187-01-01
Configuring the XC Series
Configuring the XC Series
Once the charger is connected to a battery on bank 1 or to AC, it is live and it may
be configured. There will be a short delay of about 15 seconds before the remote
display begins reporting. The remote display will use this time to query the charger
for the current operating conditions.
If AC was already applied, ensure that the charger is in on by pressing ON/STANDBY
if necessary.
To configure the battery bank type:
1. Press and hold MODE until
(setup) is displayed.
2. Press TYPE to select the battery type configuration programming mode.
The XC Series will default to Bank 1 and will show the present battery type
setting.
3. Press BANK repeatedly to select which bank you are setting up. The bank
indicator light will illuminate to show which bank has been selected.
4. Press TYPE repeatedly to select the battery type for each bank. When you have
selected a battery type that is different from the present configuration, the bank
indicator light flashes.
Set the TYPE according to the table below:
If your battery is
then select
Flooded Lead Acid (has removable caps intended for refilling)
GEL (any sealed type except AGM)
Absorbed Glass Mat (AGM)
Lead Calcium
Custom (if pre-configured at factory)
5. Press and hold ON/STANDBY until
is displayed to store the selected battery
type. If
is displayed, verify that you are setting the correct battery type and
try again.
6. Repeat steps 1 through 4 for all banks attached to the XC Series. Each time
is displayed for a newly programmed battery type, the charger exits the
programming mode.
7. At any time during setup, you can press ON/STANDBY once to cancel the current
change and return to charging or battery monitoring.
975-0187-01-01
2–15
Installation
To configure the charging type:
1. Press and hold MODE until
(setup) is displayed.
2. Press MODE to select 2-stage ( ) or 3-stage ( ) charging. When you have
selected a charging type that is different from the present configuration, the
bank indicator light flashes.
See “About Charging” on page 3–2.
3. Press and hold ON/STANDBY until
is displayed to store the selected mode.
4. At any time during setup, you can press ON/STANDBY once to cancel the current
change and return to charging or battery monitoring.
2–16
975-0187-01-01
Operation
3
Chapter 3 describes the operating states and provides
procedures for charging a battery and performing an
equalization.
Operation
About Charging
The XC Series has three full current rated, independently controlled outputs which
enable it to charge three different batteries or battery banks. Each output can
accommodate any one of the four allowable battery types, regardless of what
battery types are connected to the other outputs. Each output can be in a different
stage of charge, ralative to the other banks; for exampe, Bank 1 in float, Bank 2 in
absorption and Bank 3 in bulk. Each bank can accommodate a separate battery
temperature sensor. The XC Series can also perform either multiplex (3 stage)
charging, or sequential (2 stage) charging.
Important: The battery banks are not galvanically isolated from each other. They share a
common negative.
Multiplex 3-Stage Charging
In multiplex charging mode the charger will check all qualified battery banks every
15 seconds to determine which bank is most in need of charging. That bank will
then be charged for the next 15 seconds. Every 15 minutes the charger will query all
outputs and detect which battery banks are present and healthy.
The multiplex charging mode employs the 3-stage charging algorithm: Bulk,
Absorption, and Float. During the Bulk stage the battery is accepting high current.
In the Absorption stage the battery voltage is held constant and the current declines.
A battery will also "gas" (produce hydrogen and oxygen) during this stage. Finally,
in the Float stage, the charger continues to provide voltage at a lower level to
maintain the battery in a fully charged state. If there is no load on the battery, it will
typically draw very little current. The charger, however, is able to provide current to
its full rating to power DC loads on the battery. In float, if batteries are very new or
a battery is on the low end of the size range and if it is fully charged to the point
where it will not accept any more current, then the charger will enter an adaptive
float/no float behaviour where it will alternate between float charging ( ) and
resting the battery ( ).
The charger will restart the charging cycle in the Bulk stage if the battery voltage
drops below 12.5 V (12 V units) or 25 V (24 V units) for 15 minutes. After 21 days,
the charger will automatically restart charging in order to refresh the batteries.
3–2
975-0187-01-01
About Charging
Sequential 2-Stage Charging
In sequential charging mode the charger will check all battery banks every 15
minutes to determine which banks are present, healthy, and in most in need of
charge. The bank most in need of charge will then be charged for the next 15
minutes.
The sequential charging mode employs the 2-stage charging algorithm. It is the
same as the 3-stage algorithm except that there is no float stage; after the absorption
stage the charger stops providing voltage and current to the battery and enters a
"rest stage". Like the 3-stage algorithm, the charger will restart the charging cycle in
the Bulk stage if the battery voltage drops below 12.5V (12 V units) or 25 V (24 V
units) for 15 minutes. After 21 days, the charger will automatically restart charging
in order to refresh the batteries.
Charging Overview
The XC Series will perform a battery detection sequence every 15 minutes, or on
reapplication of AC, to determine which battery banks are present and healthy.
If you connect a battery when AC is disconnected, the remote will not recognize it
until the unit has performed a battery detection with AC applied.
To force a battery detection sequence,
1. Turn off AC.
2. Wait approximately 20 seconds or until all lights on the charger or remote have
gone out .
3. Turn on AC.
The charger will then perform a battery detection when AC is reapplied
The charger does not charge the banks in a pre-determined sequence. The bank
most in need of charging is the one that receives the charge. For example, if Bank 1
and Bank 2 are both charged, but Bank 1 has a load and Bank 2 does not, then the
charger may rarely charge Bank 2.
975-0187-01-01
3–3
Operation
Disqualified Batteries
The XC Series can identify when a battery will not accept a charge (battery is
damaged) or when it is fully charged (healthy) and does not require further charge.
Batteries that will not accept a charge will be removed (disqualified) from the
charging sequence until all banks are checked again (every 15 minutes). A damaged
battery will continue to be disqualified each cycle and the charger will not waste
energy trying to charge it. Under some conditions it is also possible that a healthy
battery that is fully charged but unable to accept current (for example, at the
moment it transitions from Absorption to Float or Rest) will be deemed unable to be
charged and temprarily removed from the charging sequence. The charger will enter
an adaptive float/no float behaviour where it will alternate between float charging
(
) and resting the battery ( ) and the 25% Charge Current indicator light on
the onboard status panel will flash. The battery will be evaluated every 15 minutes
and added back to the charging sequence when it is later able to accept charge.
If disqualification occurs during Bulk or Absorption, the battery is damaged or
there is another charging source present other than the charger itself. The remote
display will show
and the 25% Charge Current indicator light on the onboard
status panel will flash.
Measuring Battery Voltage
Use a voltmeter that has a stated accuracy of 0.5% or better on DC voltage. Place
the probes of the meter directly on the studs or plates of the charger terminals. Do
not probe on the wire lugs or other places in the battery wiring system as this will
introduce error into the measurement: the charger monitors battery voltage as
measured at the charger terminals.
Temperature Considerations
Xantrex strongly recommends that you install a Battery Temperature Sensor (BTS)
to protect your battery and improve charging accuracy. It is best to use a separate
BTS with each individual battery bank, to provide optimal charging and protection
of each bank. If no BTS is connected, the charger defaults to the charging
conditions for 40 °C (104 °F). At this temperature the charging voltage is lower to
keep batteries from overcharging; charging will be slower and the batteries will be
slightly undercharged.
3–4
975-0187-01-01
About Charging
Things to be aware of
When the XC Series is operating, fans and lights (DC loads) may vary in speed or
intensity. This is normal. The XC Series will not harm any load connected to it as
long as there is a battery present on that bank.
When you initially turn the XC Series on and configure it, it is possible that some
banks may be disqualified. Because the charger is able to detect unhealthy batteries
and disqualify them, batteries that may have appeared healthy before will now be
correctly identified as needing attention.
Perform these disqualification checks in the order shown:
1. Wait 15 minutes for the next battery detection cycle. The warning may be
temporary.
2. Verify that the battery meets the minimum AmpHour rating (XC1524: 30 Ah,
XC2524: 50 Ah, XC3012: 60 Ah, XC5012: 100 Ah)
3. Try adding a small DC load.
4. Replace the battery.
975-0187-01-01
3–5
Operation
Charging Batteries
Before you start to charge batteries read the “Important Safety Instructions” on
page v and follow all safety precautions when working with batteries.
To charge your batteries:
1. If possible, disconnect all loads from the battery, by opening a disconnect
switch, or by switching the loads off.
2. Ventilate the area around the battery thoroughly. Review the charging
instructions supplied by the manufacturer of your batteries and take any steps
required.
3. Apply AC power to the XC Series by closing the AC breaker and/or applying
shorepower or turning the generator on. The indicator lights will blink as an
initialization sequence runs, lasting typically 10 seconds. After initialization the
charging indicator light illuminates.
During charging, the charging current indicator lights show the total current
being delivered to the selected battery bank as well as any DC load applied.
4. Re-connect all loads to the battery, by closing a disconnect switch, or by
switching the loads on.
The batteries can be in one of six different stages:
Mode
Remote Display
Bulk mode
Absorption mode
Rest mode (2-stage charging)
Float mode (3-stage charging)
Equalize mode
Battery fault
3–6
975-0187-01-01
Charging Batteries
After charging is complete, the XC Series enters into one of these modes:
Float mode When the ready indicator light illuminates, all batteries are fully
charged and ready for use. If you selected the 3-stage charging mode, the XC Series
is in float mode and will maintain the batteries’ charge.
Rest mode If you selected the 2-stage charging mode, the ready indicator light
shows the charger is now in rest mode and is checking battery voltage and elapsed
time since the last charge cycle.
With either charging mode, the XC Series will begin a charging cycle 21 days after
the last cycle, or when battery voltage drops to below 12.5 V (12 V units) or 25 V
(24 V units) for 15 minutes.
975-0187-01-01
3–7
Operation
Equalizing Flooded Batteries
About Equalizing
The XC Series equalizes only flooded lead-acid or lead-calcium batteries. It does
not equalize sealed lead-acid batteries since they can be damaged by this process.
In the following conditions the remote display will show and the XC Series will
not enter equalization mode:
•
•
the battery type is set for Gel or AGM
any battery is not fully charged (all three battery banks must be charged to float
or rest stage before equalization can be activated on any bank)
•
there is an active fault on the battery you are trying to charge
Xantrex recommends that you run a normal charge cycle on the batteries before you
equalize them.
WARNING: Explosion hazard
During equalization, the battery generates explosive gases. Follow all the battery safety
precautions listed in this guide. Ventilate the area around the battery thoroughly and ensure
that there are no sources of flame or sparks in the vicinity
CAUTION: Risk of battery damage
The XC Series cannot automatically determine when to stop the equalization of a battery.
You must monitor the battery specific gravity throughout equalization to determine the end
of the equalize cycle. The one hour time-out is intended as a safety feature to require the
user to continually re-activate it as necessary after checking batteries manually, but may not
be sufficiently short to prevent battery damage.
3–8
975-0187-01-01
Equalizing Flooded Batteries
Performing An Equalization
Turn off or disconnect all DC loads on the battery during equalization. The voltage
applied to the battery during equalization may be above the safe levels for some
loads.
To equalize your batteries:
1. Check the battery electrolyte level. If necessary, refill with distilled water only.
All the cells should have similar electrolyte levels. If the levels are widely
different, it will influence the relative concentration of acid, thereby affecting
the specific gravity measurements.
2. Verify that all banks are in either float or rest mode.
3. Press MODE and BANK at the same time.
4. Press BANK to select which bank you wish to equalize. The bank indicator light
will flash to show which bank has been selected.
5. Press and hold ON/STANDBY to put the XC Series into equalization mode.
You can cancel the equalization request by pressing ON/STANDBY once.
If the battery cannot be equalized, the display will show
Check that the battery is flooded and in float mode.
.
6. When the charger is in equalize mode, the display will show
.
7. Monitor the specific gravity of each cell of the battery during equalization with
a battery hydrometer.
The equalize cycle will terminate in one hour.
Check the specific gravity of each cell and repeat the equalization cycle until
they all meet the battery manufacturer’s specifications for specific gravity or
until the specific gravity stabilizes relative to each other for an hour.
8. The charger automatically exits equalization to float mode or rest mode after 1
hour. To manually exit equalization mode early, press MODE and BANK at the
same time and then press and hold ON/STANDBY.
You can cancel the manual exit request by pressing ON/STANDBY once.
9. When equalization has finished, check the battery electrolyte level. If
necessary, refill with distilled water only.
975-0187-01-01
3–9
Operation
Transitioning the XC Series to On, Disabled or Off
There are two ways to turn the XC Series on:
•
•
connect AC power at the source
press ON/STANDBY on the remote display if AC is still connected.
There are two ways to disable the XC Series:
WARNING: Shock hazard
The XC Series still has live voltage while disabled. Even when AC power is removed, if the
XC Series is connected to a battery on bank 1, the unit will take power from the battery. The
only time the XC Series is de-energized completely is when both AC and DC are
disconnected.
•
•
disconnect AC power at the source
press ON/STANDBY on the remote display.
The XC Series continues to monitor the batteries, but will not charge them.
There is only one way to safely turn the XC Series off:
•
disconnect the AC power at the source and disconnect all DC batteries.
This is the only state where the XC Series is completely discharged.
When the XC Series is disabled or off, the remote display is inactive.
3–10
975-0187-01-01
Accessing Charger Information
Accessing Charger Information
The XC Series can give you a lot of information about the status of the charger and
the batteries.
Reading Remote Display and Onboard Status Indicator Lights
The remote display and onboard status panel show what is happening during the
charging process and are also helpful in troubleshooting. Refer to Chapter 4,
“Troubleshooting” for more information about interpreting the remote display and
onboard status indicator lights.
The remote display is designed to report on the active status of the charger. While
the unit is charging, the remote display reports only on the battery being charged at
that moment. It does not report the status of other batteries.
The Ready light on the onboard status indicator panel only illuminates when all
connected banks have reached float ( ) of 3-stage charging or rest ( ) of 2-
stage charging. If one of the three batteries has been disqualified before it reaches
float/rest stage, while the others have reached float ( ) of 3-stage charging or rest
(
) of 2-stage charging, the Ready light on the onboard status indicator panel will
not illuminate.
975-0187-01-01
3–11
Operation
Table 3-1 Reading XC Series Status
Remote
Charger Status
Display Onboard Status Indicator Lights
Charging in bulk or absorption mode.
or Charging indicator light illuminates
Remote display shows scrolling display of charging
state, battery voltage in volts and charging current in
amps.
Indicator lights indicate the charging current in % of
full charge. At transition points when the current is
changing, two indicator lights may flash alternately,
then settle into the new charging current reading.
Equalizing.
Charging indicator light flashes
Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every four
seconds if bank 2 is being equalized, and three times
every four seconds if bank 3 is being equalized.
Float mode of three stage charging or rest mode of
two stage charging.
All batteries have been fully charged.
or Ready indicator light illuminates
or 25% current indicator light flashes
A battery has been disqualified while in float mode of
three stage charging or rest mode of two stage
charging.
A battery has been disqualified while in bulk or
absorption mode.
25% current indicator light flashes
Fault indicator light illuminates
Non-charger fault condition.
Any fault condition that prevents the charger from
charging one or more banks, but is not a charger
failure. Remote display shows details of fault.
(example)
3–12
975-0187-01-01
Accessing Charger Information
Table 3-1 Reading XC Series Status
Remote
Charger Status
Display Onboard Status Indicator Lights
Battery too hot fault
Fault indicator light illuminated
100% current indicator light flashes
Battery too cold fault
Fault indicator light illuminated
10% current indicator light flashes
Charger fault condition.
Fault indicator light flashes
The charger is damaged, contact service.
Reporting While Charging or Equalizing
After configuration, the XC Series defaults to a scrolling display. As long as there
are no faults or errors to report, the remote will display the following information,
in order, for the bank presently being charged:
•
•
•
Charging Stage
Battery Voltage
Charger Current
If there is a fault or warning related to one of the banks, the fault or warning
information will display in the scrolling display before the charging state for the
bank presently being charged. Charging for banks not in fault will continue (see
“Error Messages on Remote Display” on page 4–4). Charging for the bank in fault
will resume once the fault condition is cleared.
975-0187-01-01
3–13
Operation
Reporting While Battery Monitoring
The XC Series is considered to be battery monitoring if it is experiencing a charger
level fault. If there is a charger level fault (affecting all banks), all charging will be
suspended until the charger fault is resolved (see “Error Messages on Remote
Display” on page 4–4).
The remote will display all of the following, in order:
•
•
•
•
•
•
•
•
•
•
•
•
•
Highest level charger fault or warning (if present)
Bank 1 Highest level bank fault or warning (if present)
Bank 1 Charging Stage
Bank 1 Battery Voltage
Bank 1 Charger Current
Bank 2 Highest level bank fault or warning (if present)
Bank 2 Charging Stage
Bank 2 Battery Voltage
Bank 2 Charger Current
Bank 3 Highest level bank fault or warning (if present)
Bank 3 Charging Stage
Bank 3 Battery Voltage
Bank 3 Charger Current
Reporting While Disabled
If AC power has been disconnected or if you have used the remote display to
disable the XC Series the unit is considered to be disabled. The remote display is
also disabled at this time.
While the XC Series is disabled, you may wish to see the present status of the
banks.
To view the present status of the banks:
◆ Press ON/STANDBY.
If AC power is disconnected, the remote display will show one cycle (similar to the
battery monitor cycle) for each bank that was qualified as present and healthy
during the last battery detection cycle. The remote display will turn itself off after
one complete cycle.
3–14
975-0187-01-01
Accessing Charger Information
◆ Press ON/STANDBY on the optional remote display to initialize another
cycle.
If AC power is connected, the XC Series will turn on, check which battery
banks are present and healthy, and begin charging.
While the XC Series is off, and a fault is present, the remote display will
turn itself on approximately once per minute to show the fault and then turn
itself off.
Using A Generator As Source Power
The XC Series can be run from a regular power source or from an alternate
power source such as a generator. Refer to Appendix A, “Specifications” for
AC input draw to determine the size of generator you need. Many generators
provide output voltage that is modified sine wave or modified square wave
(MSW) rather than the true sine wave (TSW) that your utility provides.
The XC Series may be used with MSW generators but the lifetime may be
reduced somewhat depending on the severity of any peak voltage
overshoots, and the severity of waveshape risetimes.
975-0187-01-01
3–15
3–16
Troubleshooting
4
Chapter 4 contains information on error codes and
procedures for troubleshooting your XC Series
charger.
Troubleshooting
Care and Maintenance
WARNING: Risk of electric shock
The XC Series contains no user serviceable components. Attempting any kind of service
will void your warranty. Contact your dealer or the manufacturer for service information.
The XC Series contains solid-state electronic components that require no
maintenance. The best care you can give the unit is to protect it from contact with
liquids, spray, or fumes which may cause corrosion. Disconnect all AC and DC
power and clean the outside of the case and wiring with a damp cloth if you suspect
it has come in contact with battery fluid, salt water, gasoline or oil, or other
corrosive material. Periodically, check all DC and AC wiring connections to be sure
they have not loosened or deteriorated. Also check all cable clamps to ensure they
are tightly fastened.
Loose battery terminals and lugs exposed to open air corrode rapidly. The corrosion
appears as a white powder or granular foam on the terminals and any nearby
exposed metal parts. If it contacts your skin, it will cause burns unless you rinse it
off immediately. Most textiles that are exposed to this corrosive eventually dissolve.
To clean battery terminals:
1. Disconnect all loads and charging sources.
2. Using the appropriate tool, remove the negative battery cable first and re-install
it last.
3. To remove any stubborn residue, sprinkle baking soda directly on the area,
scrub with a wet toothbrush (or other soft-bristle brush), add water as required,
and then rinse.
CAUTION
Take care not to allow any washing solution to enter the battery filling caps in the case of a
flooded battery, as any contamination into a cell will chemically damage it.
4. Reconnect the battery cable terminals to the battery lugs and tighten.
5. After tightening the cables, evenly coat all the exposed metal surfaces of the
battery terminals and lugs with liquid neoprene. If liquid neoprene is not
available, use a light coating of anti-corrosion grease or other sealant. Do not let
anything come between the mating surfaces of the lugs and terminals.
4–2
975-0187-01-01
Indicator Light Flashing Sequences
Indicator Light Flashing Sequences
Table 4-1 Indicator Light Sequences on the XC Series
Activity
Charger status
Charging indicator light illuminates The unit is charging in bulk or absorption mode
Charging indicator light flashes
The unit is performing the equalization charge.
(Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every
four seconds if bank 2 is being equalized, and
three times every four seconds if bank 3 is being
equalized)
Ready indicator light illuminates
Fault indicator light illuminates
The unit is either in float mode of three stage
charging or rest mode of two stage charging. All
batteries have been fully charged.
Any fault condition that prevents the charger from
charging one or more banks, but is not a charger
fault condition - remote display shows details of
fault. Example:
(battery reverse
polarity detected)
Fault indicator light flashes
Charger fault condition - remote display shows
followed by
. The charger is damaged,
contact service.
Charging current indicator lights
illuminate
These lights indicate the charging current. At
transition points when the current is changing, two
indicator lights may flash alternately, then settle
into the new charging current reading.
Charging current indicator lights
flash
100% indicator light flashes to indicate battery
temperature too high warning (> 50 °C, 122 °F)
10% indicator light flashes to indicate battery
temperature too low warning (< 0 °C, 32 °F)
25% indicator light flashes to indicate that a
battery has been disqualified (see page 3–4)
Charging current indicator lights
flash,
Fault indicator light illuminated
100% indicator light flashes to indicate battery
temperature too high fault (> 55 °C, 131 °F)
10% indicator light flashes to indicate battery
temperature too low fault (< -20 °C, -4 °F)
975-0187-01-01
4–3
Troubleshooting
Error Messages on Remote Display
Table 4-2 Error Messages
Onboard Status Panel
Display Indicator lights
Fault
Solution
Red fault indicator light
Fault
A fault has been detected. The fault code
flashing or illuminated
will be shown immediately after
.
AC Low
Warning
Check AC connections, check AC
availability at source.
Red fault indicator light
illuminated
Reverse
Polarity
Reverse Polarity Battery connected.
Check connections. Ensure correct
polarity (negative connected to negative,
positive connected to positive).
Red fault indicator light
flashing
Charger
Hardware
Fault
Call for service.
Over-
temperature
Warning
Allow the XC Series to cool. Improve
ventilation or install in cooler location. If
the temperature increases, the XC Series
will enter the fault level and stop
functioning.
Red fault indicator light
illuminated
Over-
temperature
Shutdown
Allow the XC Series to cool. Improve
ventilation or install in cooler location.
Green 10% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated
Battery Too
Allow batteries to warm up before
Cold Warning attempting to charge again. Charging a
battery that has frozen is a potential
explosion hazard. If the temperature
drops, the XC Series will enter the fault
level and stop charging the affected bank.
4–4
975-0187-01-01
Error Messages on Remote Display
Table 4-2 Error Messages
Onboard Status Panel
Display Indicator lights
Fault
Solution
Red fault indicator light
illuminated
Green 10% indicator light
flashes
Battery Too
Cold
Shutdown
Allow batteries to warm up before
attempting to charge again. Charging a
battery that has frozen is a potential
explosion hazard.
Display green bank indicator
light for affected battery bank
illuminated
25% current indicator light
flashes
Battery
Disqualified
Warning
Wait 15 minutes for the next battery
detection cycle. The warning may be
temporary.
Verify that the battery meets the minimum
AmpHour rating (XC1524: 30 Ah,
XC2524: 50 Ah, XC3012: 60 Ah,
XC5012: 100 Ah)
Try adding a small DC load.
Replace the battery.
Display green bank indicator Over Voltage
Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
light for the affected battery
bank illuminated
Shutdown
Warning
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with electric start.
If the warning level escalates without
being corrected, the XC Series enter the
fault level and stop charging the affected
bank.
Red fault indicator light
illuminated
Display green bank indicator
light for the affected battery
bank illuminated
Over Voltage
Shutdown
Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with electric start.
975-0187-01-01
4–5
Troubleshooting
Table 4-2 Error Messages
Onboard Status Panel
Display Indicator lights
Fault
Solution
Green 100% indicator light
flashes
Display green bank indicator
light for the affected battery
bank illuminated
Battery too
Hot Warning
Allow battery to cool. Improve ventilation
or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss. If the temperature
increases, the XC Series will enter the
fault level and stop charging the affected
bank.
Red fault indicator light
illuminated
Green 100% indicator light
flashes
Battery too
Allow battery to cool. Improve ventilation
Hot Shutdown or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss.
Display green bank indicator
light for affected battery bank
illuminated
Cannot apply The operation you have tried to execute
change
cannot be completed.
Red fault indicator light
illuminated
No batteries
detected
The charger did not detect any batteries.
4–6
975-0187-01-01
Problem Solving
Problem Solving
If the remote display is not functioning, troubleshoot your XC Series using the
tables below. In the event that you have a problem with your XC Series, the
following tables will help you to identify the problem and offer possible solutions to
the problem.
Symptom
Indicator lights do not illuminate when charger is connected to AC power.
Possible Cause
Solution
No power at AC source and no Ensure that power is available at the source and a
battery connected on bank 1
Defective AC wiring
Charger level fault
battery or bank is connected on bank 1
Replace wiring
Call for service
Symptom
Fault indicator light illuminates. XC Series stops functioning.
Possible Cause
Solution
XC Series does not detect battery Check quality of battery connection and wires.
for one of following reasons:
Ensure correct polarity (negative connected to
negative, positive connected to positive).
•
•
•
poor connection
reverse polarity connection
damaged wiring
XC Series internal temperature
too hot
Allow the XC Series to cool. Improve ventilation or
install in cooler location.
975-0187-01-01
4–7
Troubleshooting
Symptom
Fault indicator light flashes. XC Series stops functioning.
Possible Cause
XC Series hardware failure
Solution
Call for service
Symptom
Symptom
Symptom
Fault indicator light illuminates. 100% indicator light flashes.
Possible Cause
Solution
Battery temperature is too hot for
safe charging.
Allow battery to cool. Improve ventilation or
install in cooler location. It may indicate a shorted
cell in the battery or excessive water loss.
Fault indicator light illuminates. 10% indicator light flashes.
Possible Cause
Solution
Battery temperature is too cold for
safe charging.
Allow batteries to warm up before attempting to
charge again. Charging a battery that has frozen is
a potential explosion hazard.
XC Series completes a charging cycle, but the battery voltage seems (about 2 volts)
too low.
Possible Cause
Solution
Battery has a shorted cell.
Check the battery.
Verify you are attempting to charge a battery correctly
rated at 12 volts nominal (XC3012, XC5012) or 24
volts nominal (XC1524, XC2524). Re-check the
battery voltage with all loads removed and the battery
is at rest for about an hour.
4–8
975-0187-01-01
Problem Solving
Symptom
The XC Series appears to be taking too long to charge battery. Ready indicator light
does not illuminate after 24 hours of charging.
Possible Cause
Solution
Battery capacity is too high for the Use a higher capacity charger.
XC Series model.
Load connected to battery is
draining charge current so that
battery does not recharge.
Disconnect load or switch load off.
Battery has a damaged cell.
Replace battery.
Symptom
The XC Series will not transition to equalization mode.
Possible Cause
Solution
Battery is the wrong type, or set to Verify battery type is set to Gel or AGM. These
the wrong type to equalize.
battery types cannot be equalized.
Not all batteries are fully charged.
Wait for all batteries to be in float (
) of 3-stage
charging or rest (
) of 2-stage charging before
attempting to equalize (the ready indicator light will
illuminate).
An active fault is present on the
Clear the active fault (see Table 4-2 on page 4–4)
bank you are attempting to equalize.
975-0187-01-01
4–9
4–10
Specifications
A
Appendix A details the specifications for the
XC Series.
Specifications
Physical Specifications
Dimensions
Base unit:
367 mm x 240 mm x 106 mm
14.45 in. x 9.45 in. x 4.17 in.
Remote Display: 118 mm x 41 mm x 32 mm
4.65 in. x 1.6 in. x 1.26 in.
Weight
5.7 kg (12.6 lbs)
AC input connections Two color-coded No. 16 AWG wires (L, N) and one
No. 18 AWG (G) minimum 152 mm (6 in.) long in a separate
AC wiring enclosure with 21.3 mm (0.84 in.) hole provision for
connection of a ½ inch North American "trade size" cable clamp
or conduit hub or international PG 13.5 or PG16 or M20 gland or
cable strain relief fitting.
DC output connections Four right-angle M6 studs (3 positives and 1 common
negative) for battery cable ring terminals and one M6 mm DC
equipment ground
Electrical Specifications
Number of battery bank outputs
3 isolated, independently controlled outputs
Nominal battery voltage
12 V units: 12 VDC
24 V units: 24 VDC
Normal operating output range
12 V units: 0 – 16 VDC
24 V units: 0 – 32 VDC
Nominal operating AC voltage
Rated DC output current (total)
110 – 240 VAC
XC3012: 30 A (up to 15 V)
XC5012: 50 A (up to 15 V)
XC1524: 15 A (up to 30 V)
XC2524: 25 A (up to 30 V)
Absorption voltage (in VDC for
XC3012 and XC5012)
(Multiply VDC by 2 to get the
absorption voltage for XC1524
and XC2524)
50 °C (122 °F)
13.7
25 °C (77 °F) <0 °C (32 °F)
Flooded
Gel
AGM
14.4
14.2
14.3
15.5
15.1
14.9
14.8
16.0
13.5
13.8
Lead-calcium 14.8
A–2
975-0187-01-01
AC Input Specifications
Float voltage (in VDC for XC3012
and XC5012)
(Multiply VDC by 2 to get the
float voltage for XC1524 and
XC2524)
50 °C (122 °F)
12.8
25 °C (77 °F) <0 °C (32 °F)
Flooded
Gel
AGM
13.5
13.8
13.4
13.5
14.2
14.5
13.9
14.2
13.1
12.9
Lead-calcium 12.8
Equalize mode current
50% rated output
Equalize mode—maximum output XC3012: 16.0 VDC
voltage
XC5012: 16.0 VDC
XC1524: 32.0 VDC
XC2524: 32.0 VDC
Off-state current draw (with
remote installed)
XC3012:
XC5012:
XC1524:
XC2524:
<20 mA
<20 mA
<15 mA
<15 mA
AC Input Specifications
AC input voltage range
100 – 260 VAC at full power
90 – 105 VAC at 80% restricted load
Note: Charger may not start with input voltage
<100 VAC
Maximum AC input current
at 100 VAC
at 184 VAC
XC3012: 6 AAC
XC5012: 10 AAC
XC1524: 6 AAC
XC2524: 10 AAC
XC3012: 4.3 AAC
XC5012: 5.7 AAC
XC1524: 4.3 AAC
XC2524: 5.7 AAC
Power factor at rated load
Frequency
≥0.95
47 – 63 Hz
Efficiency – peak
12 V units: 80% @ 120 VAC, 83% @ 230 VAC
24 V units: 85% @ 120 VAC, 87% @ 230 VAC
Surge protection
Line-to-neutral surge protector rated at 275 VAC
975-0187-01-01
A–3
Specifications
Temperature Specifications
Nominal ambient
Operating range
Current de-rating
Storage
25 °C (77 °F)
0 – 50 °C (32 – 122 °F)
approx. 2% (Imax) / °C (50 – 65 °C) (122 – 149 °F)
-40 – 80 °C (-40 – 176 °F)
Humidity
5 – 95%, RH non-condensing
Protection Features
Battery reverse polarity
No damage incurred by reverse polarity.
Safe non-operating battery voltage 35 VDC maximum
Over-voltage limits
Output current limit
Over-temperature
The XC Series will stop charging any bank that has a
voltage greater than + 0.5 V over the temperature
compensated absorption voltage. It will restart when
this voltage is + 0.2 V.
XC3012: 30 – 33 ADC
XC5012: 50 – 55 ADC
XC1524: 15 – 16.5 ADC
XC2524: 25 – 27.5 ADC
Internal charger temperature is measured. Unit shuts
down and restarts as follows:
•
•
Over-temperature shutdown at 75 °C (167 °F)
Over-temperature restart at 70 °C (158 °F)
Current derating in ambient
temperatures
Rated current to 50 °C (122 °F)
2%/ °C derating above 50 °C (122 °F)
Battery over-temperature
protection
Battery temperature, as sensed by the battery
temperature sensor (if installed), results in the
charger no longer charging the individual battery or
bank at a battery temperature of 55 °C (132 °F).
A–4
975-0187-01-01
Approvals
Approvals
Safety
CSA/NRTL approved to CSA107.2 and UL1236, including the marine
supplement, ignition protection, and UL1564
EN60335-1, EN60335-2-29 Battery Chargers
ISO 8846: Ignition Protection for Small Craft
ABYC E11 - Alternating Current and Direct Current Electrical Systems on
Boats
ABYC A20 - Battery Charging Devices
NFPA70/1996 US NEC for home and RV installation requirements
EMC
Other
FCC Class B
CE marked, meeting EMC Directive 89/336/EEC (referencing EN55014-1,
EN55014-2, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11)
CISPR25 (similar to SAE J1113-41) Class 1 on DC outputs
KKK-A-1822 Rev D - Federal Specification for the Star-of-Life Ambulance
975-0187-01-01
A–5
A–6
Warranty and Product Information
Limited Warranty for:
Xantrex XC3012 Battery Charger
Xantrex XC5012 Battery Charger
Xantrex XC1524 Battery Charger
Xantrex XC2524 Battery Charger
"XC Series"
What does this warranty cover and how long does it last? This Limited Warranty is provided by
Xantrex Technology Inc. ("Xantrex") and covers defects in workmanship and materials in your Xantrex XC Series
product. This warranty lasts for a Warranty Period of 24 months from the date of purchase at point of sale to you,
the original end user customer. This Limited Warranty is transferable to subsequent owners but only for the
unexpired portion of the Warranty Period.
What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge,
provided that you notify Xantrex of the product defect within the Warranty Period, and provided that Xantrex
through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty.
Xantrex will, at its option, use new and/or reconditioned parts in performing warranty repair and building
replacement products. Xantrex reserves the right to use parts or products of original or improved design in the
repair or replacement. If Xantrex repairs or replaces a product, its warranty continues for the remaining portion of
the original Warranty Period or 90 days from the date of the return shipment to the customer, whichever is greater.
All replaced products and all parts removed from repaired products become the property of Xantrex.
For United States and Canada returns, Xantrex covers both parts and labor necessary to repair the product, and
return shipment to the customer via a Xantrex-selected non-expedited surface freight within the contiguous United
States and Canada. Alaska and Hawaii are excluded. Contact Xantrex Customer Service for details on our freight
policy for return shipments outside of the contiguous United States and Canada.
How do you get service? If your product requires troubleshooting or warranty service, contact your dealer. If
you are unable to contact your dealer, or the dealer is unable to provide service, contact Xantrex directly at:
Phone:
Fax:
1 800 670 0707 (toll free North America)
+34 93 470 5330 (Europe)
1 360 925 5097 (direct and rest of world)
1-800 994 7828 (toll free North America)
+34 93 473 6093 (Europe)
1 360 925 5143 (direct and rest of world)
Email:
[email protected] (North America and rest of world)
[email protected] (Europe)
Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your
product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call
Xantrex or check our website to see if your product can be repaired at one of these facilities.
In any warranty claim, dated proof of purchase must accompany the product and the product must not have been
disassembled or modified without prior written authorization by Xantrex.
Proof of purchase may be in any one of the following forms:
•
•
•
The dated purchase receipt from the original purchase of the product at point of sale to the end user, or
The dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) status, or
The dated invoice or purchase receipt showing the product exchanged under warranty
975-0187-01-01
WA–1
Warranty and Product Information
What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the
product or costs related to the removal, installation, or troubleshooting of the customer's electrical systems. This
warranty does not apply to and Xantrex will not be responsible for any defect in or damage to :
a) the product if it has been misused, neglected, improperly installed, physically damaged or altered, either
internally or externally, or damaged from improper use or use in an unsuitable environment;
b) the product if it has been subjected to fire, water, excessive corrosion, biological infestations, or input voltage
that creates operating conditions beyond the maximum or minimum limits listed in the Xantrex product
specifications including high input voltage from generators and lightning strikes;
c) the product if repairs have been done to it other than by Xantrex or its authorized service centers (hereafter
"ASCs");
d) the product if it is used as a component part of a product expressly warranted by another manufacturer;
e) the product if its original identification (trade-mark, serial number) markings have been defaced, altered, or
removed.
DISCLAIMER OF WARRANTY
THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN
CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF
ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND
LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE
PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF
MANUFACTURER'S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE),
INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED
UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE
PERIOD STIPULATED UNDER THIS LIMITED WARRANTY.
IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES HOWEVER ARISING WHETHER IN
CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND,
ANY LOSS OR DAMAGE TO PROPERTY, ANY PERSONAL INJURY, ANY DAMAGE OR INJURY
ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE, OR THE INCORRECT INSTALLATION,
INTEGRATION OR OPERATION OF THE PRODUCT.
Exclusions If this product is a consumer product purchased in the United States, federal law does not allow an
exclusion of implied warranties. To the extent you are entitled to implied warranties under federal law, to the extent
permitted by applicable law they are limited to the duration of this Limited Warranty. Some states do not allow
limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or
exclusion of incidental or consequential damages, so the above limitation(s) or exclusion(s) may not apply to you.
This Limited Warranty gives you specific legal rights. You may have other rights which may vary depending on the
country, province, or state.
WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO
BY IT IN WRITING, XANTREX
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY
TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION
PROVIDED BY IT IN CONNECTION WITH THE PRODUCT; AND
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES,
WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT
ARISE OUT OF THE USE OF SUCH INFORMATION.
THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER'S RISK.
WA–2
975-0187-01-01
WARNING: LIMITATIONS ON USE
Please refer to your product user manual for limitations on uses of the product. Specifically, please note that the
Xantrex Battery Charger is not intended for use in connection with life support systems and Xantrex makes no
warranty or representation in connection with any use of the product for such purposes.
Xantrex Technology, Inc.
8999 Nelson Way
Burnaby, British Columbia
Canada
V5A 4B5
Return Material Authorization Policy
If your product requires warranty service, please contact your dealer first. If you are unable to contact your dealer,
or your dealer is unable to provide service, contact Xantrex.
Before returning a product directly to Xantrex you must obtain a Return Material Authorization (RMA) number and
the correct factory "Ship To" address. Product shipments will be refused and returned at your expense if they are
unauthorized returned without an RMA number clearly marked on the outside of the shipping box, if they are
shipped collect, or if they are shipped to the wrong location.
When you contact Xantrex to obtain service, please have your instruction manual ready for reference and be
prepared to supply:
•
•
•
•
The serial number of your product
Information about the installation and use of the unit
Information about the failure and/or reason for the return
A copy of your dated proof of purchase
When you ship:
1.
Package the unit safely, preferably using the original box and packing materials. Please ensure that your product is shipped
fully insured in the original packaging or equivalent. This warranty will not apply where the product is damaged due to
improper packaging.
Include the following:
2.
•
•
•
•
The RMA number supplied by Xantrex Technology Inc clearly marked on the outside of the box.
A return address where the unit can be shipped. Post office boxes are not acceptable.
A contact telephone number where you can be reached during work hours
A brief description of the problem
Please contact Xantrex for details of the freight policy for your country of purchase. For United States and Canada
returns, ship the unit prepaid to the address provided by your Xantrex customer service representative.
If you are returning a product to a Xantrex facility in North America from outside of the USA or Canada: In
addition to the above, you MUST include return freight funds and are fully responsible for all documents, duties,
tariffs, and deposits.
If you are returning a product to a Xantrex Authorized Service Center (ASC): A Xantrex return material
authorization (RMA) number is not required. However, you must contact the ASC prior to returning the product or
presenting the unit to verify any return procedures that may apply to that particular facility.
975-0187-01-01
WA–3
Warranty and Product Information
Information About Your System
As soon as you open your Xantrex XC3012, XC5012, XC1524 or XC2524 Battery Charger package, record the
following information and be sure to keep your proof of purchase.
_________________________________
_________________________________
_________________________________
❐
❐
❐
Serial Number
Purchased From
Purchase Date
If you need to contact Customer Service, please record the following details before calling. This information will
help our representatives give you better service.
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
❐
❐
❐
❐
❐
❐
Type of installation
Length of time charger has been installed
Battery/battery bank size
Battery type (e.g. flooded, sealed gel cell, AGM)
DC wiring size and length
Description of light indicators or remote display
readout
___________________________________________
___________________________________________
❐
❐
Appliances operating when problem occurred
Description of problem
___________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
WA–4
975-0187-01-01
Xantrex Technology Inc.
Phone: 1 800 670 0707 (toll free North America)
+34 93 470 5330 (Europe)
1 360 925 5097 (direct and rest of world)
Fax:
1-800 994 7828 (toll free North America)
+34 93 473 6093 (Europe)
1 360 925 5143 (direct and rest of world)
Email: customerservice@xantrex.com (North America)
support.europe@xantrex.com (Europe)
customerservice@xantrex.com (rest of world)
Printed in Canada
975-0187-01-01
|