| Air Purifier   User’s   Guide   Important!   Read this manual   carefully, and   keep for future   reference.   Oreck ProShield Air Purifier and   Oreck ProShield Plus Air Purifier   ® Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   General Warnings . . . . . . . . . . . . . . . . . . . . . . . . 1   Placement Warnings . . . . . . . . . . . . . . . . . . . . . . 1   Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3   Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Cleaning Intervals. . . . . . . . . . . . . . . . . . . . . . . . 6   Cleaning the Pre-Filter . . . . . . . . . . . . . . . . . . . . 7   Cleaning the Truman Collector Cell . . . . . . . . . . . 7   Cleaning the Exhaust Grille. . . . . . . . . . . . . . . . . 9   Cleaning the Catalytic Oxygenator . . . . . . . . . . . . 9   Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Replacing the Optional Odor Absorber . . . . . . . . 10   Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 11   Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Contents   General Warnings   Safety   IMPORTANT SAFETY   INSTRUCTIONS   • Only use the air purifier as described in this manual.   Failure to do so may result in serious injury or death.   • Do not use the air purifier with a damaged cord or plug.   Doing so may result in electric shock, serious injury or   death. Have a qualified service technician replace any   damaged cords or plugs.   • Do not handle the unit with wet hands. Doing so may result   in electrical shock, serious injury or death. Thoroughly dry   your hands before handling any part of the air purifier.   CAUTION!   • Do not unplug by pulling on the cord. Doing so may result   in electrical sparks and fire. Unplug the unit by grasping,   and pulling the plug.   • Hair, loose clothing and body parts may get caught in the   machine resulting in injury. Keep hair, loose clothing and   body parts away from openings and moving parts.   Placement Warnings   ! WARNING!   • Do not use the air purifier outdoors or on wet surfaces.   Doing so may result in electric shock, serious injury or   death. Use only indoors and under dry conditions.   • • Do not use the air purifier in an enclosed space where   flammable, combustible or explosive gases are present.   Do not use in an area where toxic vapors, flammable dust   or oxygen tanks are present. Doing so may result in serious   injury or death. Check the location and make sure these   elements are not present.   1 CAUTION!   • Do not place open flames, including candles, directly in   front of the air purifier.   • Keep objects away from the air intake grille.   It is important to consider the following when deciding on   where to locate the air purifier:   • Position the air purifier on a flat, solid, stable surface.   Never place the unit on soft surfaces such as a bed   or sofa.   • Position the air purifier where the dirty air is not drawn   across your head or body while sitting or sleeping.   • Position the air purifier so the plug on the power cord easily   reaches a standard electrical outlet for a polarized plug.   Note: A polarized plug has one   rounded prong and one straight prong.   The rounded end goes into the   longest socket slot.   • Do not use an extension cord.   • Do not place the air purifier near sources of heat, such as   stove tops, ovens, radiators or computers.   SAVE THESE   INSTRUCTIONS   2 1. Pre-Filter: Filter large particles such as dust, hair and lint.   Features   2. Cleaning brush: Use to clean the front and back grilles.   Stores snuggly in the compartment under the cover.   3. Odor Absorber: Reduces odors and chemical fumes from   glue, solvents and synthetic materials. The air purifier   continues to filter particles from the air passing through it   with or without the odor absorber. Note: Oreck ProShield   Air Purifier has a replaceable odor absorber. Oreck   ProShield Plus Air Purifier has a permanent odor absorber   which is activated by internal ultraviolet lights and cannot   be removed.   4. Truman Cell: Electrostatically charges and collects   small particles such as dust, smoke, pollen, bacteria,   molds, viruses, and fungi.   5. Catalytic Oxygenator: Both models contain a permanent   catalytic Oxygenator which cannot be removed.   6. Exhaust Grille: Directs the flow of air as it exits the unit.   7. Power Cord: Plug into the outlet to begin use.   8. Removable Base: Allows the air purifier to stand vertically.   Simply stand the unit on its base with the Oreck logo facing   front and the control panel buttons at the top.   9. Night Light: The right end of both models will softly glow   when the night light is activated. On the Oreck ProShield   Plus Air Purifier, the logo will illuminate when the unit is   sitting on its base, or serve as a night light on the front of   the unit.   10. Cover Release Button: Press in to release the cover for   maintenance access.   11. Truman Collector Cell Light: A solid red light is included   as a handy reminder to clean the Truman Cell after 30 days.   A blinking light indicates a malfunction that has caused the   Truman cell to shut down and requires attention.   12. Speed Indicator Light: Lighting starts from the center   for the lowest motor speed to all five lights for full motor   speed.   13. Odor Absorber Light: The light indicates that it is time to   replace the odor absorber.   14. Oreck ProShield Air Purifier: On this model, this button   activates the Air Revitalizer feature which is designed   to run continuously, but may be turned OFF if desired.   Provides additional air freshness via the release of negative   ions, which can also cause dust particles to clump together   and fall out of the air passing through the air purifier. You   may notice faster dust buildup on the unit and surrounding   objects with the Air Revitalizer turned ON.   3 2 3 4 18   7 5 6 1 8 17   10   9 13   11   14 15 16   Oreck ProShield Plus Air Purifier: This model has no   Air Revitalizer but instead this button turns the internal   UV lights on or off as desired. If turned off, the unit will   continue to filters particles from the air but its odor and   VOC removal capability will be greatly reduced.   12   15. Motor Speed/Power Button: Press the power buttons   repeatedly for the desired speed.   • Silence for Silence Technology®. It’s the quietest   operation, cleaning the air as effectively but more   slowly than the high setting.   • Medium for normal use   • High for maximum cleaning   16. Night Light Button: Repeatedly press this button to change   the lighting scheme to best suit your preference.   17. Front Grille: Air enters here for the first stage of cleaning.   18. Remote Control: Remotely turns the Power ON/OFF   adjusts the Odor Control feature, Motor Speed and Night   Light. Use these buttons in the same procedure as the unit   (available only on the Oreck ProShield Plus model).   4 1. Place. Locate the air purifier on a hard surface such as   a table or desk. The unit can be placed horizontally or   vertically depending on your space. Be sure the grille is not   blocked by other objects and there are no candles or flames   near the unit.   Operation   2. Plug In. Plug into nearest standard electrical outlet that   accepts a polarized plug.   3. Select the air cleaning speed. Press the motor speed/power   button until you reach the desired speed.   3 Position   so that the air is not   drawn across the   head or body.   2 1 5 Cleaning Intervals   Proper care and cleaning of the air purifier is critical to   performance. The following chart shows the cleaning intervals   and method.   Cleaning   Part   Cabinet   Cleaning   Time   Method   As needed Wipe with damp cloth first.   If required, follow with mild,   non-abrasive cleaner.   Truman Cell 2 to 4   weeks   Spray Oreck Assail-a-Cell®   cleaner or soak in warm water   or warm water with mild   liquid detergent. Rinse and dry   thoroughly.   Pre-Filter   2 to 4   weeks   Rinse thoroughly in warm   water or as needed.   Odor   12 months, Replace (optional for odor   Absorber   or as   needed   removal). Do not wash.   Vacuum gently with a soft   brush attachment to clean if   necessary.   Air Direction As needed Use the brush provided with the   Grille   air purifier to brush away debris   in between the slots.   Catalytic   Ozone   Converter   As needed Vacuum the front surface gently   with a soft brush attachment.   Do not use any liquids for   cleaning.   ! WARNING!   Cleaning the unit while it is plugged in may result   in electric shock, electric spark and serious injury.   Unplug the unit before cleaning or maintenance.   Remove the unit from the wall if it is wall   mounted.   6 Cleaning the Pre-Filter   c The   air purifier   will not run if the   Top Cover is not   closed securely.   1 3 5 2 1. Unplug the air purifier and lay it on its side with the hinged   cover on top.   2. Open the Top Cover by pressing the Cover Release button.   3. Pull the Pre-Filter straight up and out of the Cabinet.   4. Thoroughly rinse the Pre-Filter and let it air dry before   placing it back in the Cabinet. Do not use heated or com-   pressed air as part of the drying process.   5. Slide the Pre-Filter back into the unit.   6. Close the Top Cover securely.   Cleaning the Truman Collector Cell   Note: The Truman Cell may require more frequent cleaning   if “arcing” occurs. Arcing is a sharp snapping sound that oc-   curs when large particles are collected in the Truman Cell. If   prolonged or continuous arcing occurs the Truman Cell should   be cleaned.   1. Unplug the air purifier and lay it on its side with the hinged   cover on top.   2. Open the Top Cover by pressing the Cover Release button.   3. Remove the collector cell by pulling up on the handle   (located across the top of the Truman Cell). Slide the   collector cell straight up and out.   4. Place in sink, bathtub or other location where cleaner can   cover every surface.   7 3 5 Oreck’s   1 Assail-a-Cell®   cleaner is an   excellent way to   clean the   7 collector cell.   2 5. Spray Oreck Assail-a-Cell® cleaner between each Cell Plate   and cover each surface. Allow the cleaner to soak for a few   minutes but do not let it dry. Thoroughly rinse the Truman   Cell with clean water.   An alternative method to clean the Truman Cell is to rinse or   soak it in warm water for loose debris. Mild liquid dish   detergent in water may also be used to help break down   tough dirt and residue. Thoroughly rinse the Truman Cell   with clean water.   Note: To prevent damage to the components of the Truman   Cell, do not put in dishwasher or use a cotton swab.   Tough residue such as tar from tobacco smoke may need   additional cleaning or longer soaking.   6. Allow to dry completely outside of the air purifier. Do not   use heated or compressed air to dry.   7. Place the Truman Cell back into the unit by sliding it straight   down into the slots. The Truman Cell is specially designed   so that it can only be inserted in one direction.   8. Close the Top Cover securely.   8 Cleaning the Catalytic Oxygenator   1 4 3 2 1. Unplug the air purifier and lay it on its side with the hinged   cover on top.   2. Open the Top Cover by pressing the Cover Release button.   3. Remove the Odor Absorber, Pre-Filter, and Collector Cell.   4. Vacuum the front face of the filter with a soft-brush   attachment only. Do not use liquids to clean.   5. Replace the Odor Absorber, Collector Cell and Pre-Filter.   6. Close the Top Cover securely.   Cleaning the Exhaust Grille   2 1 1. Remove the Cleaning Brush from the storage slot located   under the Top Cover.   2. Brush away debris that has collected between the Grille Slots.   3. Return the Cleaning Brush to the storage slot.   9 Maintenance   Replacing the Optional Odor Absorber   3 4 1 2 Note: The Odor Absorber can be removed and replaced in the   Oreck ProShield Air Purifier only.   1. Unplug the air purifier and lay it on its side with the hinged   cover on top.   2. Open the Top Cover by pressing the Cover Release button.   3. Flip up the two tabs located on top of the Odor Absorber.   4. Use the tabs to gently lift the odor absorber from the cabinet.   5. Replace with a new Odor Absorber. Fold the tabs down. Do   not force the Odor Absorber into the slot.   6. Close the Top Cover securely.   10   Service problems that appear to be major can often be solved   easily. You can be your own troubleshooter by reviewing this guide.   Trouble-   shooting   All other servicing should be done by an Oreck authorized   service center.   Problem   Check   Solution   Unit does not   turn ON   • Power Cord   • Plug in Power Cord   • Selector Switch • Set Selector Switch for desired blower   speed.   • Top Cover   • Make sure the top cover is securely closed   Truman Cell   light has turned   solid red.   Truman Cell   Truman Cell   Truman Cell   Truman Cell   • A solid red light is a 30 day cleaning   reminder. Wash Collector Cell. Make sure   it is thoroughly clean and dry before   reinstalling.   Truman cell   light is   blinking red   • A blinking red indicates the power supply   has shut down due to arcing or short   circuit. The cell should be inspected and   cleaned, repaired, or replaced.   Unit does   not remove   pollutants.   • Clean the Truman Cell and make sure it is   completely dry before reinstalling.   • Truman cell may be damaged. Contact   Oreck for service.   Unit sparks,   crackles and   pops.   • Sparking or popping noise (arcing) can   occur when a large particle is captured   in the Truman Cell. If the unit is arcing   excessively, the cell may be dirty. Try   cleaning the Truman Cell.   • If excessive arcing continues after   proper cleaning, the Truman Cell may   be damaged or wet. If damaged, contact   Oreck for service.   11   Problem   Check   Solution   Odor Absorber   light on unit has   turned red.   Odor Absorber   • Replace odor absorber if desired.   • If odor absorber is not replaced, remove   old odor absorber to turn off Check Odor   Absorber light.   Does not   remove odor.   Odor Absorber   • Vacuum odor absorber with a soft brush   attachment if dirty. Do not use any liquids   to clean the Odor Absorber.   • Replace odor absorber if desired.   Unit still does   not operate   properly.   Check all the   above points.   Contact Oreck for service.   12   ORECK MANUFACTURING COMPANY: (Oreck Manufac-   turing Company gives you the following limited warranty for this   product only if it was originally purchased for residential use, not   for resale, from Oreck or an Oreck Authorized Retail Dealer.)   Warranty   Oreck will repair or replace, free of charge, to the original pur-   chaser, any part that is found to be defective in material or work-   manship within three (3) years following the date of purchase for   all residential models. NOTE: If the unit is used commercially, a   one (1) year overall warranty applies.   This limited warranty does not cover the replacement of expend-   able or consumable parts such as filters, cartridges, and other   parts subject to normal wear unless they are defective in material   or workmanship.   This limited warranty does not apply to any part subjected to ac-   cident, abuse, commercial use, alteration, misuse, damage caused   by act of God, the use of voltages other than on the data plate of   this product or service of this product by other than Oreck or a   participating Factory Authorized Service Center.   Oreck does not authorize any person or representative to as-   sume or grant any other warranty obligation with the sale of this   product.   Oreck’s limited warranty is valid only if you retain proof of pur-   chase from Oreck or an Oreck Authorized Retail Dealer for this   product. If you purchase this product from any other source, your   purchase is “AS IS,” which means Oreck grants you no warranty,   and that you, not Oreck, assume the entire risk of the quality   and performance of this product, including the entire cost of any   necessary servicing or repairs of any defects.   Oreck’s liability for damages to you for any costs whatsoever aris-   ing out of this statement of limited warranty shall be limited to   the amount paid for this product at the time of original purchase,   and Oreck shall not be liable for any direct, indirect, consequen-   tial or incidental damages arising out of the use or inability to use   this product. Some states do not allow the exclusion or limitation   of incidental or consequential damages, so the above limitation or   exclusion may not apply to you.   ALL EXPRESS AND IMPLIED WARRANTIES OTHER   THAN THE LIMITED WARRANTY SET FORTH ABOVE,   FOR THIS PRODUCT, INCLUDING IMPLIED WARRAN-   TIES OF MERCHANTABILITY AND FITNESS FOR A   PARTICULAR PURPOSE ARE EXPRESSLY DENIED.   This warranty gives you specific legal rights, and you may also   have other rights which vary from state to state.   13   © 2009 Oreck Holdings, LLC.   All rights reserved. All marks, text, logo’s, product configura-   tions and registered trademarks are owned and used under the   authority of Oreck Holdings, LLC   15   |