Zephyr Ventilation Hood COK E42SX User Manual

www.zephyronline.com  
Okeanito  
COK-E36SX  
COK-E42SX  
COK-E48SX  
Model number:  
Serial number:  
Date of Purchase:  
Sales Dealer:  
©
Zephyr Corporation.  
MAY07.0101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY NOTICE ..............................................  
LIST OF MATERIALS .......................................  
2
3
INSTALLATION  
Ducting Calculation Sheet ...............................  
Mounting Height and Clearance .....................  
Ducting ..................................................................  
Specifications .......................................................  
4
5
6
7
Internal Blower .................................................... 8 - 9  
Preparing Hood for External Blower .............. 10 - 11  
Mounting the Hood ............................................ 12 - 14  
FEATURES & CONTROLS  
Controls Overview .............................................. 15 - 16  
MAINTENANCE  
Cleaning ................................................................. 17  
Lights ....................................................................... 18  
TROUBLE SHOOTING ...................................... 19  
LIST OF ACCESSORIES/PARTS ....................... 20  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
READ AND SAVE THESE INSTRUCTIONS  
WARNING  
TO REDUCE THE R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT USE THIS FAN W ITH ANY S O LID-S TATE  
L
SPE E D CONTRO DEV IC E.  
WARNING  
TO RE DUCE THE R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO PE R SONS, O B S E RVE THE FO LLOW ING:  
a. Use this unit only in the manner intendedby the manufacturer, If you have questions, contact the manufacturer.  
b. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being  
switched on accidentally.  
When the service disconnecting means cannot be locked, securely fasten a prominentwarning device, such as tag, to the service panel.  
CAUTION  
For General VentilatingUse Only. Do not Use to Exhaust Hazardous or Explosive Materials and Vapors.  
Take care when using cleaning agents or detergents.Suitable for use in household cooking area.  
WARNING  
DUC E  
TO RE  
THE R IS K O F A RA NG E TO P GR EAS E FIR E:  
a. Never leave surface units unattendedat high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low  
or mediumsettings.  
b. Always turn hood ON when cooking at high heat or when cooking flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn  
Beef Flambe)  
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.  
d. Use proper pan size. Always use cookware appropriatefor the size of the surface element.  
WARNING  
TO RE DUC E THE R IS K O F INJURY TO PERSONS IN THE EV E NT O F A RA NG E TO P G R EAS E FIR E, O B S E RVE THE FO LLOW ING :  
a. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. B E CARE FUL TO PR EV E NT BUR NS.  
If the flames do not go out immediatel ,EVACUATE AND CALL THE FIR E DE PARTME NT.  
y
b. NEV E R PIC K UP A FLAMI NG PAN - You may be burned.  
c. DO NOT US E WATE R, includingwet dishcloths or towels - a violentsteam explosion will result.  
d. Use an extinguisher ONLY if:  
1. You know you have a class AB C extinguisher, and you already know how to operate it.  
2. The fire is small and contained in the area where it started.  
3. The fire departmentis being called.  
4. You can fight the fire with your back to an exit.  
5. Based on “Kitchen Fire Sa fety Tips” publishedby NFPA.  
WARNING  
TO R E DUC E THE R IS K O F FIR E, E LEC TR IC SHOCK O R INJURY TO PER SONS, O B S E RVE THE FO LLOW ING :  
a. Installation Work and Electrical Wiring Must be Done by Qualified Person (s) In Accordance with all Applicable Codes and Standards,  
IncludingFire-Rated Construction.  
b. Sufficient air is needed for proper combustion andexhausting of gases throughthe flue (chimney) of fuel burningequipmentto prevent back  
drafting. Follow the heating equipmentmanufacturer’s guideline and safety standards such as those publishedby the National Fire Protection  
Association (NFPA), and the American S ociety for Heating, Refrigeration, and Air ConditioningEngineers (AS HRAE) and the local code authorities.  
c. When cutting or drillinginto wall or ceiling, do not damage electrical wiring and other hidden utilities.  
d. Ducted fans must always vent to the outdoors.  
WARNING  
E
TO REDUC THE R IS K O F FIR E, US E O NLY METAL DUC TW O R K.  
CAUTION  
To reduce risk of fire and to properlyexhaust air, be sure to duct air outside - Do not vent exhaust air into spaces within walls or ceilings or into  
attics, crawl spaces or garages.  
CAUTION  
To Reduce the Risk of Fire and Electric Shock, Install This Range Hood Only with Remote Blower Models CB E-1000 Rated  
Maximum6.2 amp, 120 Vac 60Hz or Integral Blowers Manufactured by Zephyr Ventilation, Models CB I-600.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL: COK-ExxS  
1 - Hood  
1 - Baffle Filter (2 on 48” model)  
2 - 50W 120V Halogen Light Bulbs GU-10  
2 - 40W 120V Appliance Bulbs  
1 - Utensil Rail  
2 - Telescopic Duct Covers  
1 - Ceiling Mounting Bracket (pre attached to duct cover)  
1 - Wall Mounting Bracket  
1 - HARDWARE PACKET  
7 - 2” Wood Screws  
7 - Anchors  
7 - 1/2” Washers  
4 - 1/2” Screws 5x15mm  
4 - 10mm Washers  
1 - SMALL HARDWARE PACKET  
1 - T ool  
3 - Short Set Screws (4 on 48” Model)  
1 - HARDWARE PACKET, EXTERNAL BLOWER KIT  
1 - 8” Collar  
1 - External Blower Wiring Box with Wires  
10 - 1/2” Self Tapping Screws  
10 - 4mm Internal Diameter Washers  
NO DUCTING IS PROVIDED  
EXTERNAL AND INTERNAL BLOWER SOLD SEPARATELY  
Make sure to remove the protective film off of the hood before installation in order to make removal of the film  
easier. Be careful not to scratch the stainless steel while installing.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Equivalent number  
length x used  
Equivalent number  
Duct pieces  
Duct pieces  
=
Total  
length x used  
=
Total  
Ft.  
Ft.  
Ft.  
Ft.  
3 1/4” x 10”  
Rect.,  
straight  
1 Ft.  
1 Ft.  
1 Ft.  
15 Ft.  
x (  
x (  
x (  
x (  
)
)
)
)
=
Ft.  
6” Round  
wall cap  
with damper  
30 Ft.  
x (  
)
=
7” Round,  
straight  
=
=
=
Ft.  
Ft.  
6” Round,  
roof cap  
30 Ft.  
x (  
x (  
)
=
=
7” Round,  
straight  
6” round to 1 Ft.  
3 1/4” x 10”  
rect.  
)
transition  
3 1/4” x 10”  
Ft.  
6” round to 16 Ft.  
3 1/4” x 10”  
rect.  
x (  
)
=
0
Rect. 90  
elbow  
transition  
90 elbow  
0
Ft.  
3 1/4” x 10”  
Rect. 45  
elbow  
9 Ft.  
x (  
)
=
0
Ft.  
Ft.  
7” Round,  
15 Ft.  
9 Ft.  
x (  
x (  
)
=
=
0
90 elbow  
Ft.  
Ft.  
3 1/ 4” x 10” 24 Ft.  
Rect. 90  
flat elbow  
x (  
x (  
)
)
=
=
0
7” Round,  
45 elbow  
)
0
3 1/4” x 10”  
Rect.  
wall cap  
30 Ft.  
5 Ft.  
Ft.  
Ft.  
Ft.  
7” Round  
wall cap  
with damper  
30 Ft.  
30 Ft.  
x (  
x (  
x (  
)
=
=
=
with damper  
Ft.  
Ft.  
3 1/4” x 10”  
Rect. to  
x (  
x (  
)
)
=
=
7” Round,  
roof cap  
)
)
6” round  
transition  
7” round to 8 Ft.  
3 1/4” x 10”  
rect.  
3 1/ 4” x 10” 15 Ft.  
Rect. to  
6” round  
transition  
transition  
0
90 elbow  
Ft.  
7” round to 15 Ft.  
3 1/4” x 10”  
rect.  
x (  
)
=
Ft.  
6” Round,  
90 elbow  
15 Ft.  
9 Ft.  
x (  
x (  
)
)
=
=
0
transition  
0
90 elbow  
Ft.  
Ft.  
6” Round,  
Subtotal column 2 =  
Subtotal column 1 =  
Ft.  
Ft.  
Ft.  
0
45 elbow  
Subtotal column 1 =  
Total ductwork  
=
Maximum Duct Length: For satisfactory air movement,  
the total duct length of a 3 1/4” x 10” rectangular, 6” or 7”  
diameter round ductshould not exceed 100 equivalent feet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum mount height between range top to hood bot-  
tom should be no less than 28".  
Min 32"-Max 52"  
Maximum mount height should be no higher than 36".  
It is important to install the hood at the proper mounting  
height. Hoods mounted too low could result in heat  
damage and fire hazard; while hoods mounted too high  
will be hard to reach and will loose its performance and  
efficiency.  
14 1/2"  
Min 96"-Max 124”  
Min 28"-Max 36"  
If available, also refer to range manufacturer's height  
clearance requirements and recommended hood  
mounting height above range. Always check your local  
codes for any differences.  
36"  
*Minimum ceiling height of 96”. Hood  
mounted at 28” above cooking surface.  
**Maximum ceiling height of 124". Hood  
mounted at 36" above cooking surface.  
Minimum Duct Size:  
DUCT ING  
A minimum of 6” round or 3-1/4 x 10"  
rectangular duct work must be used to maintain  
maximum air flow efficiency with the 600 cfm  
internal blower. A minimum of 10"to 8” round must be  
used with the 1000 cfm external blower.  
Round - 6” minimum at 600 cfm  
Round - 10" to 8” minimum at 1000 cfm  
Rect angular - 3 1/4” x 10” minimum only if  
using internal blower at 600 cfm. Using  
rectangular ductwork will require a transition  
adapter (not provided, but readily available at  
most hardware stores).  
Always use rigid type metal duct work only.  
Flexible ducts could restrict air flow by up  
to 50%.  
DAMAGE-SHIPMENT / INSTALLATION:  
Use calculation worksheet to compute total  
duct work.  
• Please fully inspect unit for damage  
before installation.  
ALWAYS, when possible, reduce the number  
or transitions and turns. If a reducer is used,  
install a long reducer instead of a pancake  
reducer. Reduce duct size as far away from  
opening as possible.  
If the unit is damaged in shipment , return  
the unit to the store in which it was bought  
for repair or replacement.  
If the unit is damaged by the customer ,  
repair or replacement is the responsibility  
of the customer.  
If turns or transitions are required:  
Install as far away from opening and as far  
apart, between 2, as possible.  
If the unit is damaged by the installer (if  
other than the customer), repair of replace  
ment must be made by arrangement  
between customer and installer.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING FIRE HAZARD  
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must  
be ducted to the outside.  
Use single wall rigid Metal ductwork only.  
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.  
Some Ducting Options:  
External  
Blower  
Roof Pitch w/  
Flashing & Cap  
side wall  
cap with  
gravity  
External  
Blower  
damper  
Soffit or crawl space  
Soffit or crawl space  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
19 3/4”  
10”  
19 3/4”  
16 5/8”  
13 3/8”  
14 1/2”  
LOGO CHENG DESIGN BY ZEPHIR  
95°  
11 7/8”  
22 5/8”  
36, 42,48”  
5" - 36"  
8"- 42"  
3 1/2"-48"  
6"  
15”  
8 5/16”  
9 3/16”  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTENTION  
The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external  
blower model CBE-1000 please turn to page “10”. Before installing, verify that motor spins freely.  
The internal blower kit consists of the blower  
and capacitor box with wiring.  
1. Position blower as shown.  
2. Att ach blower to flange as shown using  
the provided 1/2” 5x15mm screws with  
washers.  
3. P osition capacitor box as shown.  
4. Secure capacitor bo x to hood using the  
provided 1/2” self tapping screws.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Remove existing grounding screw and  
attach grounding wire from capacitor box.  
6. Re-attach grounding screw to finish  
installation of capacitor box. Refer to Fig-A on  
previous page.  
7. Attach short capacitor connector to blower  
connector.  
8. Attach long capacitor connector to control  
board connector.  
9. Use plastic tie to hold wiring together.  
10. Remove wood block  
Final view of internal blower install.  
Continue to page “12” for hood installation instructions.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTENTION  
The following are intructions on preparing your hood for installation with external blower model CBE-1000.  
For instructions on installing internal blower model CBI-600 please turn to page “8”.  
NOTE: Please refer to the CBE-1000 manual for external blower mounting instructions.  
The external blower kit consists of an 8”  
collar, and external blower wiring box. The  
external blower is purchased separately.  
1. Remove screws from internal flange.  
2. Remove internal flange from hood.  
3. Position 8” collar as shown.  
4. Att ach 8” collar to hood as shown using  
provided 1/2” self t apping screws.  
5. Attach external blower wiring box to top of  
hood using provided 1/2” self t apping  
screws.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Position cover onto external blower  
wiring box.  
7. Secure cover to box with provided screw.  
8. Attach connector from external blower  
wiring box to control board box connector  
inside hood.  
9. Attach grounding wire from external blower  
wiring box to grounding screw of the junction  
box. Refer on Fig-A in diagram below .  
10. Final view of external blower preparation  
Continue to page “12” for hood installation instructions.  
For external blower installation please refer to the manual  
included with the external blower.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duct Cover  
C/L  
21”  
Ceiling Bracket  
Duct Cover  
Ceiling Bracket  
B
A
C
14 1/2”  
7 1/2”  
min 28”  
max 36”  
C/L  
Attach screws to  
ceiling bracket  
C/L  
1. Measure from cooking surface to hood bottom, level and mark line A.  
2. Plum and mark center line.  
3. Mark mounting height, line B (14 1/2” from line A). This is the top of the hood.  
4. Measure up, 7 1/2” from line A and mark mounting spread from C/L Line C. (21”)  
5. Follow center line up to the ceiling, measure and mark 6” from the wall. Make sure the spot you mark is still  
on the center line. This is where the center of the duct cover ceiling bracket will mount.  
6. Place duct cover ceiling bracket onto ceiling and mark the (2) holes where screws will be attached. If attaching  
bracket to drywall only, drill and insert provided anchors into the marked holes. Cut out inside diameter of the  
ceiling bracket to fit the 6” or 8” round duct work. Attach bracket to ceiling with (2) screws provided.  
7. Prepare duct work and electrical.  
All Electrical work must be performed by a qualified electrician or person with similiar  
technical know and background.  
For personal safety, remore house fuse or open circuit beaker before beginning installation.  
Do not use extension cords or adapter plug with this appliance.  
Follow National Electrical Codes or prevailing local codes and ordinances.  
Electrical Supply:  
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch  
circuit, protected by a 15 or 20 ampere cicuit breaker or time delay fuse. Wiring must be 2 wire with ground.  
Please refer to Electrical Diagram labeled on product.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Top  
gap between  
bracket and  
wall  
B
C
A
Bottom  
Attach screws to both  
sides of the duct covres  
and secure to ceilingbracket.  
10”  
Electrical  
1. Place wall bracket on line C. Position top of wall bracket so it is even with the 21” mounting spread. Make  
sure bracket is attached to wall as shown in the diagram. The top of the wall bracket should have a gap between  
it and the wall. The bottomshould be flush against the wall. Use (3) 2” wood screws to attach bracket to wall. Use  
anchors if not mountingto studs.  
2. Lift hood onto wall bracket, there is a lip on the back of the hood which will rest on the wall bracket. Secure in  
place by *screwing (2) screws with washers throughhood into the wall. There are two holes at the bottominside  
the hood in which to do this.  
3. Place telescopic duct covers on top of hood and extend top duct cover to the ceiling bracket. Attach duct cover to  
ceiling bracket with the providedscrews.  
4. Run duct work down to top of motor. Attach electrical wiring from ceiling to wiring on top of motorhousing. (slide  
duct cover up towards ceiling to gain access to the motorhousing)  
* Note: If installing onto drywall only with no wall studs present, attach E Z anchors (not provided) into the wall.  
Please see page 15 for external blower installation instructions.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set  
screw  
Front  
Back  
1. Attach utensil rail to hood canopy. A small hole has been pre-drilled into the canopy to provide a starting point  
to attach the first utensil rail post. After the first post is lined up with the hole, gently slide the rest of the rail onto  
the canopy. (note: be careful not to scratch the stainless steel when performing this step, this is why there is a  
starter hole).  
2. Attach a short set screw into eac h post in order to hold utensil rail onto canopy.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Blower On/Off  
Display (Speed level, Delay Off Indicator, Filter Clean/Change)  
2
6
Mood Light On/Off  
Lights On/Off/Hold to Dim  
15 Min Delay Off  
Adjust 3 Speed Levels  
4
3
1. Blower On/Off  
By pressing  
, the blower is switched On and Off.  
2. Speed Selection  
The 3 speed levels are selected by pressing  
The display indicates level selected.  
to decrease and  
to increase speed level.  
3. Delay Off  
This is used for programmed shut down of blower and lights 15 minutes after the function is activated.  
Press once, a dot flashes in the lower right hand side of display  
The hood will completely shut down in 15 minutes.  
indicating the function is on.  
4. Lights On/Off/Dim  
Switch lights On and Off by pressing  
5. Advance Display Functions  
6. Mood Light On/Off  
once. To dim lights, press  
again.  
This switch turns the mood lights On and Off. Press IN to turn on, press again to turn OFF.  
Filters Clean Reminder (Metal):  
After every 30 hours of use, the display will start flashing an  
filters from residue and possible clogs.  
reminding you to clean the baffle  
The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain  
blower efficiency. If improperly maintained, residue from cooking will sift through filters and cause damage to  
hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter Clean Reminder (Standard Baffle Filters fitted):  
A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. They  
need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in  
the microprocessor will automatically indicate by a  
flashing when the metal filters need to be cleaned after  
every 30 hrs. of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwasher.  
Filter Clean Reminder:  
When  
flashes on display, the baffle  
Clean Filters  
filters installed are required to be cleaned.  
display <A> flashes  
This will occur after every 30 hours of use.  
Re-setting Function:  
Reset the Filter Clean Reminder timer when  
filters are cleaned and re-installed (with  
hood off). Press and hold  
5 seconds, the display will appear; hold for  
approximately 5 seconds until on dis-  
play disappears . The Filter Clean  
for approx.  
To Reset  
display from <C> to < >  
hold 5 secs.  
Reminder function is now re-set and a new  
30 hours elapse cycle is initiated.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Surface Maintenance:  
Clean periodically
w
ith hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent or steel  
wool/scouring pads which will scratch and damage surface.  
For heavier soil use liquiddegreaser  
After cleaning, you may use
 
non-abrasive stainless
 
steel polish/ cleaners, topolish 
and buff out the stainless
 
luster  
and grain. Always scrub lightly with clean cotton cloth, and with the grain.  
Do not use any productcontainingchlorine bleach. Do not use “orangecleaners.  
Baffle Filters  
The Metal Filters fitted by the factory are intended  
to filter out residue and grease from cooking. They  
need not be replaced on a regular basis but are  
required to be kept clean.  
Filters should be cleaned after every 30 hours of  
use. Use the Filter Clean Reminder function on the  
controls to determine when filters require cleaning.  
12 3/4”  
Handles  
Remove filter by sliding towards you and  
pullingdown (Fig. 1).  
Remove and clean by hand or in dishwasher  
Spray degreasing detergent and leave to soak if  
heavily soiled.  
15”  
Dry filters and re-install before using hood.  
ReplacingBaffle Filters  
Should filters wear out due to age and prolonged  
use, contact Zephyr to purchase replacements.  
(Fig. 1)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing Light Bulbs:  
CAUTION: Light bulbs become extremely hot when turned on. DO NOT touch bulbs until switched off  
and cooled. Touching hot bulbs may cause serious burns.  
Make sure all power is turned off and bulbs are not hot.  
Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now protudefrom the hood  
allowingyou to remove the bulb.(B e careful when releasing retain clip as it is under pressure to hold it in place)  
Replacement halogen bulbs are available at most stores which sell light bulbs. Purchase type GU-10, 120 V, 50 W.  
Press together  
torelease clip  
HalogenBulb  
To replace mood lightingbulb,remove baffle filter from hood. Lift up the metal plate which is inside the hood on the left  
and right sides. It is held on with two philips head screws. Unscrew mood lightingbulb counter-clockwise and replace  
with a standard 40W, 125V-1 30V mediumbase bulb.  
MetalPlate  
MoodLightingBulb  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Issue  
Cause  
What todo  
1. The power source is not turned ON.  
1. Make sure the circuit breaker and the unit’s  
power is ON.  
After installation, the unit  
doesn’t work?  
2. The power line and the cable locking connector is  
not connecting properly.  
2. Check the power connection with the unit is  
connected properly.  
3. The switch board and control board wirings  
are disconnected.  
3. Make sure the wirings between the switch  
board and control board are connected properly.  
4. On the switch board, Black/White wire of White  
wire is disconnected.  
4. Make sure the Black/White wire or White wire  
connects properly.  
5. The switch board or control board is defective.  
1. The motor is defective, possible seized.  
5. Change the switch board or control board.  
1. Change the motor.  
Light works, but motor is  
not turning.  
2. The thermally protected system detects if the motor  
is too hot to operate and shuts the motor down.  
2. The motor will function properly after the  
thermally protected system cool down.  
3. Damaged capacitor.  
3. Change the capacitor.  
1. Tighten the motor in place.  
2. Change the motor.  
1. The motor is not secure in place.  
2. Damaged blower wheel/makes noise.  
The unit is vibrating.  
3. The hood is not secured in place.  
1. Defective halogen bulb.  
2. The light bulb is loose.  
3. Check the installation of the hood.  
1. Change the halogen bulb.  
2. Tighten the light bulb.  
The motor is working,  
but the lights are not.  
1. The hood might be hanging too high from the  
cook top.  
1. Adjust the distance between the cook top  
and the bottom of the hood within 24” and  
32” range.  
The hood is not venting  
out properly.  
2. The wind from the opened windows or opened  
doors in the surrounding area are affecting the  
ventilation of the hood.  
2. Close all the windows and doors to eliminate the  
outside wind flow.  
3. Remove all the blocking from the duct work or  
duct opening.  
3. Blocking in the duct opening or ductwork.  
4. Adjust the duct opening direction.  
4. The direction of duct opening is against the wind.  
5. Using the wrong size of ducting.  
5. Change the ducting to at least 6” or higher  
for the internal blower and 8” or higher for the  
external blower.  
1. Remove filter and reinstall it or change the  
baffle filter.  
1. Baffle filter is loose.  
Filter is vibrating.  
1. Turn circuit breaker which controls the hood off  
for at least 15 minutes.  
Turn it back on and this should fix the problem.  
1. Control board needs to be reset.  
After hood has been  
installed for a period of  
time, it stopped working.  
1. Replace control b oard.  
1. Defective control board.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part Description  
Part#  
Halogen Bulb GU-10, 120V, 50W  
Incadescent Bulb T29 127V 40 W  
Z0B-0020  
Z0B-0003  
Accessory Description  
Internal Blower, 600 cfm  
External Blower, 1000 cfm  
Duct Cover Extension Kit  
Part#  
CBI-600  
CBE-1000  
Z1C-00OK  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO OBTAIN SERVICE UNDER WARRANTY  
or any Service Related Questions, please call:  
1-888-880-8368  
Staple your receipt here.  
Proof of the original purchase  
date is needed to obtain service  
under the warranty.  
TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date.  
Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.  
One Year Service Repair Warranty:  
For one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or  
components due to manufacturing defects.  
Two Years Parts Warranty:  
For two years from date of original purchase, we will provide free of charge, nonconsumable replacement parts or  
components that failed due to manufacturing defects. Consumable parts not covered by this warranty include: Light Bulbs,  
Metal and Charcoal Filters.  
Who is Covered:  
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland states,  
Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited.  
There might be costs associated with  
shipping the products to our designated service locations or you might need to pay service technician's travel costs, to have  
the appliance repaired in-home.  
This Warranty will be Voided when:  
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instruc-  
tions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with  
equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents.  
What is Not Covered:  
Consumable parts such as light bulbs, filters, and fuses. Services outside of service area and the labor cost incurred in  
connection with the removal, shipping and reinstallation cost, nor does it cover any other contingent expenses. The natural  
wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven  
cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Service trips to your  
home to teach you how to use the product. Damage of product caused by accident, fire, floods or act of God.  
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and  
does not extend to subsequent owners of this product. Any applicable implied waranties, including the warranty of  
merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original  
purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.  
Have your product proof of purchase with date ready for warranty issues.  
Or write to:  
Zephyr Corporation  
Service and Warranty Department  
395 Mendell Street  
San Francisco, CA 94124  
JAN07.0101  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weslo Treadmill WETL259051 User Manual
West Bend Fondue Maker 88999 User Manual
Westinghouse Furnace FG6RL User Manual
Whirlpool Freezer EV130C User Manual
Whirlpool Refrigerator 6GC5THGXKS00 User Manual
Whirlpool Washer Dryer LTG5243DZ0 User Manual
Wolf Appliance Company Range DF484CG User Manual
Xantech Universal Remote RC68+ User Manual
Yamaha Motorcycle FJR1300 User Manual
Zanussi Oven 291578 User Manual