Williams Furnace 6501 User Manual

Electric Forsaire  
Counterflow Furnaces  
Totally automatic  
thermostat-controlled,  
low-cost heating for one  
to two rooms – easy and  
inexpensive to install!  
The practical choice for those areas  
where natural or propane gas is not  
convenient to install. It provides low-  
cost, floor-to-ceiling comfort (31,400  
Btu/hr), is thermostatically controlled,  
and is ideal for basements and room  
additions.  
Freestanding or recessed, the Electric  
Forsaire is totally automatic and  
includes a wall-mounted thermostat.  
Our decorator styling is at home almost  
anywhere with a scratch-resistant, soft-  
white finish to complement your décor.  
31,400 Btu/hr.  
9.2 kW  
Electric Forsaire  
This model’s powerful counterflow blower system  
receives air at ceiling level, warms it and quietly delivers it  
at floor level to give an equalized floor-to-ceiling  
temperature! Installs easily and inexpensively.  
Design Features  
Freestanding or recessed, Forsaire Electric Furnaces are ideal for homes, apartments, offices,  
schools, cabins and many other applications  
Underwriters Laboratories (UL) Listed  
Heating capacity of 31,400 Btu/hr  
Multi-room heating with optional outlet kit  
Attractive, décor compatible, scratch and abrasion resistant powder-coat, soft-white finish  
Counterflow blower system circulates ceiling-to-floor warm air  
Occupies less than one square foot of floor space  
Totally automatic fan controls and safety devices  
Wall-mounted thermostat included  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Forsaire Electric Furnace  
Heating Output Btu/hr  
Dimensions  
Operating  
CFM  
Discharge Air Shipping Weight  
Model  
KW Input  
AMPS  
Voltage Min-Max  
115V  
Temp at 240V  
(lbs.)  
Width  
at 240V  
at 208V  
Depth Height  
3144030  
9.2  
31,400  
23,600  
207 - 253  
14"  
7"  
72½"  
375  
40  
80oF Rise  
60  
Easy Installation  
Features  
Forced air electric wall furnace requires less than one square foot of floor  
space and provides warm air circulation for maximum comfort.  
All wiring and controls are easily accessible from the front.  
Transformer, terminal block, relay and motor are factory-  
prewired with thermostat wires pigtailed outside. Total system  
plus individual elements are protected by safety limit switches.  
The 9.2 kW input, 31,400 Btu/hr output model delivers heat into one or  
two rooms by a large, quiet blower. This model may be recessed into the  
stud space or surface mounted. With a cabinet depth of seven inches,  
recessed installation provides a projection of only three inches into the  
living space. A freestanding application solves the problem in otherwise  
hard-to-heat areas. Totally automatic thermostat, fan controls and safety  
devices are factory supplied.  
Blower System  
Powerful, lint-free patented peripheral blower system and heavy-  
duty motor combine to deliver warm air smoothly and quietly  
on vibration-free mountings. Blower features self-cleaning air  
scoop design. Motor, cooled by centrifugally swept air steam, is  
equipped with self-aligning porous bearings. No filter required.  
Thermostat  
Relay and 24-volt wiring provide optimum safety and operation.  
Low differential thermostat prevents excessive temperature  
swings.  
Dimensional Data  
TOP  
6½"  
2¼"  
7"  
14"  
Accessories  
18"  
Rear-Outlet Register  
Mount flush on rear wall for heat to be delivered through the  
register.  
Model 6501, shipping weight 7 lbs.  
6501  
72½"  
BACK  
12"  
S
I
FRONT  
D
E
Diffuser Grille  
A snap-on diffuser grille is available for all models. When warm  
air discharges from the front, a diffusing grille can be used to  
divert heat to the right, left or both directions.  
8"  
6704  
Model 6704 - One-Way Diffusing Grille  
Shipping weight 3 lbs.  
Finished  
4"  
Floor  
Model 6703 - Two-Way Diffusing Grille  
Shipping weight 3 lbs.  
6-5/16"  
6703  
Typical Installations  
Recommended Minimum Clearances  
6" between the furnace and adjacent walls  
0" between the furnace and floor  
Important  
· Read owner's manual before using/installing.  
RECESSED  
WITH OPTIONAL  
REAR OUTLET  
RECESSED  
FREESTANDING  
WITH OPTIONAL  
REAR OUTLET  
FREESTANDING  
WITH FRONT  
WITH FRONT  
OUTLET ONLY  
OUTLET ONLY  
· Photographs are representative only.  
· Check local codes and ordinances for permitted uses.  
· Consult installation manual for clearances prior to installation.  
· We reserve the right to amend product specifications without notice.  
· Installation and servicing recommended by a qualified service person.  
· Please read the warranty for any limitations or disclaimers. All parts  
carry a one-year limited warranty.  
250 West Laurel Street · Colton, California 92324 USA  
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009  
Consumer Line: (888) 256-6465  
Homeowner Assistance: (909) 426-0978  
Subject to Change without Notice  
© 2008 Williams Furnace Co.  
Printed in U.S.A.  
All Rights Reserved  
L1005 05/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Westinghouse Flat Panel Television P2650HR User Manual
Westinghouse Indoor Furnishings W 259 User Manual
Whirlpool Appliance Trim Kit AKP 161 User Manual
Whirlpool Dehumidifier AD030 User Manual
Whirlpool Oven GSC308PRB01 User Manual
Whirlpool Washer 8182674 User Manual
X10 Wireless Technology Home Security System MS18A User Manual
Zanussi Dishwasher 531338 User Manual
Zanussi Ventilation Hood ZB960 User Manual
Zanussi Ventilation Hood ZHC 613 User Manual