		 Gas Dryer   
					PRODUCT MODEL NUMBERS   
					WGD94HEX, WGD95HEX, WGD97HEX   
					Front view:   
					Side view:   
					27"   
					(686 mm)   
					381/8"   
					(968 mm)   
					* Approx. measurement   
					3 
					/4"*   
					(18 mm)   
					NOTE: Most installations require a minimum 5" (102 mm)   
					clearance behind the dryer for the exhaust vent with elbow.   
					See “Venting Requirements”.   
					Back view:   
					61/4"   
					(159 mm)   
					Recommended installation clearances (dryer only):   
					3"   
					(76 mm)   
					18" min.   
					(457 mm)   
					48 in.2 min.   
					(310 cm2)   
					297/8"*   
					(759 mm)   
					Water   
					53/4"*   
					(146 mm)   
					31/2"*   
					(89 mm)   
					Vent   
					24 in.2 min.   
					(155 cm2)   
					Gas   
					5"   
					3"   
					(76 mm)   
					(127 mm)   
					61/8"*   
					(156 mm)   
					3/4"*   
					(18 mm)   
					143/8"   
					(365 mm)   
					253/4"   
					1"   
					(25 mm)   
					1"   
					(25 mm)   
					(654 mm)   
					Installation spacing for recessed area   
					or closet installation   
					All dimensions show recommended and minimum spacing allowed.   
					■ 
					Additional spacing should be considered for ease of   
					installation and servicing.   
					■ 
					■ 
					Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.   
					Additional spacing should be considered on all sides   
					of the dryer to reduce noise transfer.   
					■ 
					■ 
					For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered   
					doors with equivalent ventilitation openings are acceptable.   
					Companion appliance spacing should also be considered.   