IMPORTANT INSTRUCTIONS  
IMPORTANT NOTE: Installation of the Wolf gas multi-  
function cooktop must be completed by a qualified  
installer.  
If the information in this guide is not followed  
exactly, a fire or explosion may result, causing  
property damage, personal injury or death.  
Read this entire installation guide prior to installation and  
save for the local inspector’s reference. The homeowner  
should keep this installation guide for future reference.  
This appliance must be installed in accordance with  
National Electrical Codes, as well as all state, municipal  
and local codes. The correct voltage, frequency and  
amperage must be supplied to the appliance from a dedi-  
cated, grounded circuit which is protected by a properly  
sized circuit breaker or time delay fuse. The proper  
voltage, frequency and amperage ratings are listed on the  
product rating plate.  
Installation and service must be performed by a  
qualified installer, service agency or the gas supplier.  
Warranty service must be performed by Wolf factory  
certified service.  
Do not store or use gasoline or other flammable  
vapors and liquids in the vicinity of this or any other  
appliance.  
The Wolf multi-function cooktop is manufactured for use  
with natural gas or LP gas. Check the product rating plate  
for type of gas.  
A ventilation hood or downdraft system is recom-  
mended for use with the multi-function cooktop.  
In Massachusetts: Installations and repairs must be  
performed by a qualified or licensed contractor,  
plumber or gasfitter qualified or licensed by the  
state, province, or region where this appliance is  
being installed. Only use gas shut-off valves  
Record the model and serial numbers before installing  
the multi-function cooktop. Both numbers are listed on the  
product rating plate, located on the underside of the  
module. Refer to the illustration below.  
approved for use within the state, province or region  
where this appliance is being installed. A flexible gas  
connector, when used, must not exceed 3' (.9 m).  
Wolf Multi-Function Cooktop  
Model Number  
Serial Number  
IM15/S  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electrical switch.  
Do not use any phone in your building.  
Immediately call your gas supplier from a neighbor’s  
phone. Follow the gas supplier’s instructions.  
If you cannot reach your gas supplier, call the fire  
department.  
RATING PLATE  
Location of rating plate.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
4
Overall Dimensions  
Installation Specifications  
MULTI-FUNCTION COOKTOP  
Failure to locate the multi-function cooktop without the  
proper clearances will result in a fire hazard.  
21" (533)  
IMPORTANT NOTE: Installation of the Wolf gas multi-  
function cooktop must meet minimum clearance require-  
ments shown in the installation specifications illustration  
on the following page.  
15"  
(381)  
The Wolf multi-function cooktop is intended for indoor  
use. An adequate supply of fresh air is required to assure  
proper combustion and ventilation. It is designed to fit a  
standard 24" (610) deep base cabinet with 25" (635) deep  
countertop. Before making the countertop cut-out, verify  
that the module will clear the side walls of the base  
cabinet.  
5" (127)  
1
/2" (13)  
SIDES  
1" (25) FRONT / BACK  
There should be at least 51/2" (140) clearance between the  
countertop and any combustible surface directly below  
the multi-function cooktop.  
If the multi-function cooktop is not installed above an  
oven, the gas service may be supplied through the floor.  
When an oven is installed below the cooktop, unless you  
are using cabinets deeper than 24" (610), it is recom-  
mended that the electrical supply be placed in the base  
cabinet to the right of the oven. Refer to the illustration  
on the following page for specifics on placement of the  
electrical and gas supply.  
It is recommended that you use a Wolf cooktop ventilation  
hood, downdraft, pro hood or hood liner with the multi-  
function cooktop. Refer to the Wolf design guide.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
5
wolfappliance.com/specs  
Installation Specifications  
MULTI-FUNCTION COOKTOP  
SIDE  
CABINET  
30" (762) min  
COUNTERTOP  
TO COMBUSTIBLE  
MATERIALS  
13" (330)  
max  
18" (457) min  
SEE COUNTERTOP  
CUT-OUT BELOW  
7" (178) TO  
COMBUSTIBLE*  
7" (178) TO  
COMBUSTIBLE*  
(
)
4" 102  
15"  
36" (914)  
FLOOR TO  
G
E
(381)  
COUNTERTOP  
15" (381)  
LOCATION OF GAS  
AND ELECTRICAL  
EXTENDS ON FLOOR  
5"  
(127)  
SIDE VIEW  
FRONT VIEW  
*Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.  
NOTE: Application shown allows for installation of two 15" (381) modules side by side.  
14" (356)  
CUT-OUT  
WIDTH  
1
2 /2" (64) min*  
1
19 /4" (489)  
CUT-OUT  
DEPTH  
1
FRONT  
2 /2" (64) min  
COUNTERTOP CUT-OUT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
Gas Supply Requirements  
6
GAS SUPPLY LINE  
IMPORTANT NOTE: The gas multi-function cooktop must  
EXPLOSION HAZARD: Use a certified gas supply line  
and install a gas shut-off valve. Securely tighten all gas  
connections. Failure to follow these instructions can  
result in explosion, fire or death.  
be connected to a regulated gas supply.  
A gas supply line of 3/4" (19) rigid pipe must be provided  
to the cooktop. For LP gas, piping or tubing size can be  
1/2" (13) minimum. LP gas suppliers usually determine the  
size and materials used on the system. If local codes  
permit, a certified, 1/2" (13) or 3/4" (19) ID flexible metal  
appliance connector is recommended to connect the  
cooktop to the gas supply line. The gas pressure regulator  
on the cooktop has 1/2" (13) female threads.  
IMPORTANT NOTE: This installation must conform with  
local codes and ordinances. In the absence of local  
codes, installations must conform with American National  
Standard, National Fuel Gas Code ANSI Z223.1—latest  
edition or CANI—B149.1 or 2.  
IMPORTANT NOTE: The supply line must be equipped  
with an approved external gas shut-off valve located near  
the cooktop in an accessible location. Do not block  
access to the shut-off valve. Refer to the illustration below.  
The gas multi-function cooktop is equipped for use with  
natural or LP gas. It is design certified by the Canadian  
Standards Association (CSA) for natural or LP gases. The  
product rating plate, located on the underside of the  
cooktop, has information on the type of gas that should be  
used. Refer to the illustration below. If this information  
does not agree with the type of gas available, contact your  
authorized Wolf dealer or local gas supplier. For local  
dealer information, visit the find a showroom section of  
our website, wolfappliance.com.  
The Wolf natural gas multi-function cooktop will function  
up to an altitude of 10,250' (3124 m) without any adjust-  
ment. LP gas cooktops will function up to 8,600' (2621 m)  
without adjustment. If the installation exceeds these eleva-  
tions, contact your authorized Wolf dealer for a high  
altitude conversion kit.  
Before connecting the gas supply, make sure all valves  
are in a closed position. Do not connect the gas supply  
to an appliance that shows any sign of damage.  
SHUT-OFF VALVE  
OPEN POSITION  
TO APPLIANCE  
GAS SUPPLY  
RATING PLATE  
Location of rating plate.  
Gas shut-off valve.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
7
wolfappliance.com/specs  
Gas Supply Requirements  
GAS MANIFOLD PRESSURE  
Natural Gas: Standard orifices are set for 5" (12.5 mb)  
The maximum gas supply pressure to the regulator  
should never exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).  
WC (water column).  
LP Gas: Standard orifices are set for 10" (25 mb) WC.  
Gas Supply Pressure: The maximum gas supply  
pressure to the regulator should never exceed 14"  
(34.9 mb) WC; .5 psi (3.5 kPa) for natural and LP gas.  
The minimum line pressure is 7" (17.5 mb) WC for  
natural gas and 11" (27.4 mb) WC for LP gas.  
Gas Pressure Regulator: To control and maintain a  
uniform gas pressure in the gas manifold, the unit must  
be used with a gas pressure regulator. The burner  
orifices, etc. are sized for the gas pressure delivered by  
the supplied regulator. Do not remove the regulator.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
Electrical Requirements  
8
IMPORTANT NOTE: Electronic ignition systems operate  
within wide voltage limits, but proper ground and polarity  
are necessary. In addition to checking that the electrical  
outlet provides 120 V AC power and is correctly grounded,  
the outlet must be checked by a qualified electrician to  
see if it is wired with correct polarity.  
ELECTRICAL SHOCK HAZARD: Plug into a grounded  
3-prong outlet. Do not remove ground prong. Do not  
use an adapter. Failure to follow these instructions can  
result in electric shock, fire or death.  
The Wolf multi-function cooktop requires a 120 V AC,  
60 Hz, 15-amp, fused electrical supply. A time-delay fuse  
or circuit breaker is recommended. It is recommended that  
a separate circuit serving only this appliance be provided.  
A ground fault circuit interrupter (GFCI) is not recom-  
mended and may cause interruption of operation.  
WIRING DIAGRAM  
The wiring diagram below covers the control circuit for the  
Wolf multi-function cooktop.  
SPARK  
MODULE  
3
CONDUCTOR  
WHITE  
RED  
POWER CORD  
WHITE  
GRN  
1
2
1
2
ELECTRICAL GROUND  
N
A
BLK  
RED  
The 6' (1.8 m) power cord is equipped with a 3-prong,  
grounding plug for protection against shock hazard. The  
power cord must be plugged into a mating 3-prong  
grounded outlet, grounded to conform with the National  
Electrical Code, ANSI/NFPA 70 latest edition, or Canadian  
Electrical Code (CSA) and all local codes and ordinances.  
Refer to the illustration below.  
BLACK  
RED  
WHITE  
WHITE  
BLACK  
IMPORTANT NOTE: This appliance must be properly  
grounded to avoid electrical shock hazard. Do not ground  
to a gas pipe.  
Wiring diagram.  
GROUNDING  
PLUG  
GROUNDED  
ELECTRICAL OUTLET  
Electrical ground.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Specifications  
9
wolfappliance.com/specs  
Installation Specifications  
MULTIPLE COOKTOP INSTALLATION  
Multiple Cooktops  
COUNTERTOP CUT-OUT  
2 Modules  
3 Modules  
WIDTH  
291/4" (743)  
441/2" (1130)  
593/4" (1518)  
441/4" (1124)  
591/2" (1511)  
501/4" (1276)  
If the multi-function cooktop is to be used in combination  
with additional cooktops or modules with a filler strip, refer  
to the chart below for the countertop cut-out width. The  
dimensions are derived by adding an additional 11/4" (32)  
for each additional unit, to give you the total countertop  
cut-out width. Dimensions include the filler strip.  
4 Modules  
30" (762) Cooktop / Module  
30" (762) Cooktop / 2 Modules  
36" (914) Cooktop / Module  
When multiple cooktops are installed side by side, each  
unit must have its own separate, recommended electrical  
circuit. When multiple gas cooktops are installed next to  
one another, they can receive their gas supply from a  
common line. However, each unit must have its own gas  
pressure regulator.  
When two or more cooktops or modules are installed  
together, an integrated module filler strip is recommended.  
The filler strip and other accessories are available through  
your authorized Wolf dealer. For local dealer information,  
visit the find a showroom section of our website,  
wolfappliance.com.  
IMPORTANT NOTE: Review specific installation instruc-  
tions for product to product capabilities.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Installation  
10  
Install the Cooktop  
Remove the multi-function cooktop and gas pressure  
regulator from its shipping carton and discard packing  
materials.  
Attach the brackets to the burner box by inserting the  
clips into the rectangular punchouts on the left and right  
side of the burner box. Insert the 31/2" (89) clamping  
screws into the brackets. Use a screwdriver to tighten the  
clamping screws against the underside of the countertop.  
Refer to the illustration below. Do not overtighten screws.  
Lower the multi-function cooktop into the countertop  
cut-out opening. Center the cooktop in the opening and  
check that the front edge of cooktop is parallel to the front  
edge of the countertop. Check that all required clearances  
are met. Using a pencil, outline the rear edge of the  
cooktop frame on the countertop. Remove the cooktop  
from the countertop opening.  
IMPORTANT NOTE: Do not seal the cooktop to the coun-  
tertop. It must be removed if service is necessary.  
IMPORTANT NOTE: When repositioning the multi-function  
cooktop in the countertop opening, lift the entire cooktop  
up from the opening to prevent scratching the countertop.  
Apply the foam strip, included in the hardware package,  
to the underside of the multi-function cooktop frame.  
Refer to the illustration below.  
Reinsert the multi-function cooktop into the countertop  
opening. Align the rear edge of the cooktop frame with the  
pencil line and check that it is parallel to the front edge of  
the countertop. Lift the entire cooktop to make adjust-  
ments.  
COUNTERTOP  
BURNER  
BOX  
BURNER BOX  
FOAM  
STRIP  
BRACKET  
CLIP  
1
3 /2" (89)  
CLAMPING  
SCREW  
Foam strip.  
Installation brackets.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Installation  
11  
wolfappliance.com/specs  
Install the Cooktop  
GAS PRESSURE REGULATOR  
GAS SUPPLY CONNECTION  
Install the gas pressure regulator with the arrow on the  
regulator pointing up toward the unit and in a position  
where you can reach the access cap. Refer to the illustra-  
tion below.  
Assemble the flexible metal connector from the gas supply  
pipe to the gas pressure regulator. You will need to deter-  
mine the fittings required, depending on the size of your  
gas supply line, flexible metal connector and shut-off  
valve. Refer to the illustration below.  
IMPORTANT NOTE: All connections must be wrench-tight-  
ened. Do not make connections to the regulator too tight,  
as this may crack the regulator and cause a gas leak. Do  
not allow the regulator to turn on the pipe when tightening  
fittings.  
Use a pipe joint compound made for use with natural and  
LP gas. If a flexible metal connector is used, be sure the  
tubing is not kinked.  
Open the gas shut-off valve in the gas supply line. Wait a  
few minutes for the gas to move through the line. Refer to  
the illustration on page 6.  
GAS LEAK TESTING  
Use a brush and liquid detergent to test all gas connec-  
tions for leaks. Bubbles around connections will indicate a  
leak. If a leak appears, shut off the gas supply and adjust  
connections. Then check connections again. Clean the  
detergent solution from the cooktop.  
COOKTOP  
ARROW  
POINTS UP  
ACCESS  
CAP  
Never test for a gas leak with a match or other flame.  
Gas pressure regulator.  
SHUT-OFF  
VALVE  
GAS PRESSURE  
REGULATOR  
ADAPTER  
ADAPTER  
NIPPLE  
FLEXIBLE  
METAL CONNECTOR  
NIPPLE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Installation  
12  
Install the Cooktop  
COMPLETE THE INSTALLATION  
VERIFY OPERATION  
Once the multi-function cooktop has been checked for  
gas leaks, plug the power cord into the grounded electri-  
cal outlet. Place the burner head on the burner base and  
position the burner grate over the burner assembly.  
The burner of the gas multi-function cooktop uses an  
electronic igniter in place of a standing pilot. When the  
control knob is pushed in and turned to the HIGH position,  
the system creates a spark to light the burner. This  
sparking continues until the electronic ignition senses a  
flame.  
Read the entire Wolf multi-function cooktop use & care  
guide included with the unit. It contains important safety,  
operation, service and warranty information.  
To check operation of the burner, push in and turn the  
control knob to the HIGH position. The flame should light  
within four seconds.  
Before operating, clean the multi-function cooktop thor-  
oughly with hot water and a mild detergent. Rinse and dry  
with a soft cloth. This removes any residual oil and grease  
left on the surface from the manufacturing process. Refer  
to care recommendations in the use & care guide.  
If the burner does not light properly, turn the control knob  
to the OFF position. Check that the burner head is in the  
proper position. Make sure the power cord is plugged in  
and the circuit breaker or house fuse has not blown.  
Check that the gas shut-off valve is in the open position.  
Check operation again; if the burner does not light  
properly at this point, contact Wolf factory certified  
service.  
IMPORTANT NOTE: Initial lighting of the burner may take  
slightly longer as air in the system must be purged before  
gas can be supplied to the burner.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multi-Function Cooktop Installation  
13  
wolfappliance.com/specs  
Cooktop Removal  
Troubleshooting  
IMPORTANT NOTE: If the multi-function cooktop does not  
operate properly, follow these troubleshooting steps:  
The multi-function cooktop must be disconnected from  
the electrical and gas supply prior to removal.  
Verify that electrical power is being supplied to the  
cooktop.  
Check the gas supply and electrical connections to  
ensure that the installation has been completed  
correctly.  
IMPORTANT NOTE: Removal of the multi-function cooktop  
should only be performed by Wolf factory certified service.  
If removing the multi-function cooktop is necessary for  
cleaning or service, shut off the gas supply. Disconnect  
the electrical and gas supply. Remove the mounting  
brackets on each side of cooktop and remove. Reinstall in  
the reverse order and check gas connections for leaks.  
Check that the gas supply shut-off valve is in the open  
position.  
Check polarity of the electrical outlet if excessive  
igniter clicking occurs immediately after installation.  
Follow troubleshooting procedures outlined in the  
Wolf gas multi-function cooktop use & care guide.  
If the multi-function cooktop still does not operate  
properly, contact Wolf factory certified service. Do not  
attempt to repair the cooktop yourself. Wolf is not  
responsible for service required to correct a faulty  
installation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Information  
Service Information  
14  
If service is necessary, maintain the quality built into your  
multi-function cooktop by contacting Wolf factory certified  
service.  
For the name and number of Wolf factory certified service  
nearest you, check the contact & support section of our  
website, wolfappliance.com or call Wolf customer care at  
800-222-7820.  
When calling for service, you will need the model and  
serial numbers of the multi-function cooktop. Both  
numbers are listed on the product rating plate located on  
the underside of the cooktop. Refer to the illustration for  
the location of the rating plate.  
RATING PLATE  
Location of rating plate.  
IMPORTANT NOTE: Installation and service must be  
performed by a qualified installer or service agency.  
Warranty service must be performed by Wolf factory  
certified service.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein  
may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.  
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.  
Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc.  
(collectively, theCompany Marks.) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820  
817485 REV-A  
3/2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym WEBE07920 User Manual
Weslo Treadmill WETL118060 User Manual
Westinghouse Dishwasher WSF6602 User Manual
Westinghouse Outdoor Ceiling Fan UL ES VintageII WH09 User Manual
Whirlpool Double Oven W10748900C User Manual
Whirlpool Washer 6LSR7244EQ0 User Manual
Whirlpool Washer Dryer 3363573 User Manual
X10 Wireless Technology Stereo Receiver VR31A User Manual
Zanussi Dishwasher ZSF2450 User Manual
Zebra Technologies Printer P520i User Manual