INSTALLATION, OPERATION AND CARE OF  
GAS COUNTERTOP CHARBROILERS  
GENERAL  
Gas Countertop Charbroilers are designed for commercial use only and feature fast,  
efficient gas heat. Each burner is controlled by an adjustable gas valve. Cast radiants  
are located directly above each burner to maintain uniform temperature. Radiants are  
easily removed for cleaning when cool.  
Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid  
surface to be level or sloped. Grooves, cast in the top grates, permit fat runoff and  
reduce flaring when tilted towards the front. A grease drawer is provided to collect fat  
run-off; it opens to the front for inspection or drain-off.  
Model  
Number of Burners  
BTU/hr Input Rating  
54,000  
ACB20 / VACB20  
ACB25 / VACB25  
ACB36 / VACB36  
ACB47 / VACB47  
ACB60 / VACB60  
ACB72 / VACB72  
3
4
72,000  
6
108,000  
8
144,000  
11  
13  
198,000  
234,000  
INSTALLATION  
UNPACKING  
Immediately after unpacking, check for possible shipping damage. If the broiler is found  
to be damaged, save the packaging material and contact the carrier within 15 days of  
delivery.  
Before installing, verify that the type of gas (natural or propane) and the clearance  
dimensions (see page 4) agree with the specifications on the rating plate which is located  
on the upper front corner on the right side.  
LOCATION  
The installation location must be kept free and clear of combustibles. Do not obstruct the  
flow of combustion and ventilation air. DO NOT install the charbroiler adjacent to open  
burners or fryers.  
Sufficient air should be allowed to enter the room to compensate for the amount of air  
removed by any ventilating system and for combustion of the gas burners. Do not  
obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases  
through and above the broiler's top grate. Position the broiler in its final location. Check  
that there are sufficient clearances to service the broiler and to make the required gas  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
supply connection(s). Provide 24" clearance at the front for cleaning, maintenance,  
service and proper operation.  
Minimum clearances to combustible construction are 12" to the back and 9" to the sides.  
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides.  
INSTALLATION CODES AND STANDARDS  
The Charbroiler must be installed in accordance with:  
In the United States of America:  
1. State and local codes.  
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but  
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained  
from The American Gas Association Accredited Standards Committee Z223, @ 400  
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA,  
1 Batterymarch Park Quincy, MA 02169-7471  
NOTE: In the Commonwealth of Massachusetts  
All gas appliances vented through a ventilation hood or exhaust system equipped with  
a damper or with a power means of exhaust shall comply with 248 CMR.  
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available  
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
In Canada:  
1. Local codes.  
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)  
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the  
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3  
Burners  
BURNERS, RADIANTS, AND TOP GRATES  
The top grates are shipped flat (top-side  
down) from the factory for stock pot use.  
For broiling, the top grates can be left in  
Radiants  
the flat position or reversed so they slope  
forward for grease run-off. Remove the  
cast iron radiants (Fig. 1) and inspect and  
remove the shipping tape used during  
shipping to hold the burners in place.  
Reassemble the radiants and the top  
grates. Unpack the supercharger burner  
dividers and install between burners. The  
tabs on the superchargers should be  
inserted in the slots at the front of the fire  
box.  
Top Grate  
Supercharger Burner Dividers  
Fig. 1  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LEVELING  
It is important that the charbroiler is level front to back and left to right. Areas of uneven  
heat distribution will occur on an unleveled unit. The charbroiler is equipped with  
adjustable legs. Turn the feet at the bottom of the legs to adjust to level. The unit should  
be rechecked for level anytime it has been moved.  
VENTILATION HOOD  
The broiler should be installed under a suitable ventilation hood. For safe operation and  
proper ventilation, keep the space between the charbroiler and vent hood free from any  
obstructions.  
GAS CONNECTION  
The data plate on the lower right side of the charbroiler indicates the type of gas your unit  
is equipped to burn. DO NOT connect to any other gas type.  
CAUTION: All gas supply connections and any pipe joint compound must be  
resistant to the action of propane.  
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting  
the line to the unit.  
Codes require that a gas shut-off valve be installed in the gas line ahead of the  
charbroiler. The gas supply line must be at least the equivalent of ¾” iron pipe.  
A pressure regulator is supplied and must be installed outside of the broiler when making  
the gas supply connection. Standard orifices are set for 5"WC (Water Column) for  
1
Natural Gas — 10"WC (Water Column) for Propane. Use the /8” pipe tap on the burner  
manifold for checking pressure.  
Make sure the gas piping is clean and free of  
obstructions, dirt, and piping compound.  
An adequate gas supply is necessary. Undersized or low pressure lines will restrict the  
volume of gas required for satisfactory performance. A minimum supply pressure of 7"  
W.C. for natural gas and 11" W.C. for propane gas is recommended. With all units  
operating simultaneously, the manifold pressure on all units should not show any  
appreciable drop.  
When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa),  
the charbroiler and its individual shutoff valve must be disconnected from the gas supply  
piping system. When test pressures are ½ psig (3.45 kPa) or less, the charbroiler must  
be isolated from the gas supply piping system by closing its individual manual shut-off  
valve during any pressure testing of the system.  
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR  
LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS PRESSURE REGULATOR INSTALLATION  
Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C.  
for propane gas. Minor adjustments may be required based on site specific gas pressure.  
Install the regulator as close to the broiler on the gas supply line as possible. Make sure  
that the arrow on the underside of the regulator is oriented in the direction of gas flow to  
the broiler (Fig. 2) and the regulator is positioned with the vent plug and adjustment  
screw upright (Fig. 3).  
Fig. 2  
Fig. 3  
The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural  
gas and 11-12” W.C. for propane gas. At no time should the charbroiler be connected to  
supply pressure greater than ½ psig (3.45 kPa) or 14” W.C.  
CASTER EQUIPPED CHARBROILERS  
Charbroilers mounted on stands with casters must use a flexible connector (not supplied)  
that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69  
• CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-  
Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate  
means must be provided to limit movement of the broiler without depending on the  
connector and the quick-disconnect device or its associated piping to limit broiler  
movement. Attach the restraining device at the rear of the charbroiler. If disconnection of  
the restraint is necessary, turn off the gas supply before disconnection. Reconnect the  
restraint prior to turning the gas supply on and return the charbroiler to its installation  
position.  
Note: If the Charbroiler is installed on casters and is moved for any reason, it is  
recommended that it be re-leveled (see LEVELING).  
OPERATION  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING, OR SERVICING THE CHARBROILER.  
OFF  
ON  
CONTROLS (Fig. 2)  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BURNER VALVES  
Fig. 2  
All orifices are of the fixed type and require no adjustment.  
Standing pilots should be adjusted to provide a slight yellow tip on the flame. Pilots may be  
lighted by removing adjacent cast iron top grates and radiants.  
Air shutters on the main burners must be individually adjusted to provide a blue flame. All traces  
of yellow should be adjusted out of the burner flame. While making adjustments, you may notice  
that some burners, especially to the far right and left, have a higher flame. This is part of the  
unit’s design and is a normal effect.  
1
When charbroiling, turn burner control valves to /3 or ½ to prevent overheating.  
Scrape top grates during broiling with a wire brush to keep the grates clean. Do not allow debris  
to accumulate on the grates.  
Turn flame to low setting during slack periods to conserve energy.  
The charbroiler is a free vented appliance. All products of combustion and the heat generated by  
the burners pass through the grates. When meat is placed on the grates, this blocks the venting  
and causes a temperature build-up. The charbroiler operates most efficiently with valves turned  
1
down to /3 or ½.  
LIGHTING THE GAS PILOT (Fig. 3)  
1. Turn the individual burner gas valves OFF  
and wait 5 minutes.  
Pilot  
2. Remove the Top Grates.  
Turn the  
incoming main gas supply valve ON.  
Light pilots using a taper (Fig. 3).  
3. To light the burners, turn the individual  
burner valves ON.  
Fig. 3  
TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS  
For complete shutdown: Turn the main gas supply valve OFF. (Make sure all individual burner  
valves are off before relighting.)  
PREHEATING THE CHARBROILER  
Allow the charbroiler to preheat for 30 minutes. Rub grates with cooking oil before using. Note  
that grease runs forward and drips into the trough in front of the charbroiler before draining into  
the grease drawer  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPONENT PARTS  
The Achiever Charbroiler comes with several  
standard parts as illustrated. Each can be  
easily removed and installed easily by hand for  
cleaning and maintenance. Note that the  
Burner and Deflector are an assembly and are  
NOT designed to be disassembled.  
You will find that the two of the Burner-  
Deflector assemblies on the extreme right and  
left of your charbroiler have Deflectors that are  
flat, and not bent as shown. For correct  
operation ensure that the flat Burner-Deflector  
assemblies remain on the right and left.  
CLEANING  
Scrape top grates thoroughly so grease flows to trough and grease drawer uninhibited. This  
prevents flare ups.  
Top grates may be immersed in strong commercial cleaning compound overnight. In the morning,  
rinse with hot water to remove any residues of cleaning compound.  
Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water solution.  
Places where fat, grease, or food can accumulate must be cleaned regularly.  
MAINTENANCE  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING, OR SERVICING THE CHARBROILER.  
VENT SYSTEM  
At least twice a year the exhaust hood (venting system) should be examined and cleaned.  
SERVICE  
Contact your local Service Agency for any repairs or adjustments needed on this equipment.  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
STANDS  
The charbroiler has an optional 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide  
stainless steel stand with casters or flanged legs. The front casters lock, and flanged legs  
may be bolted to the floor. The stand includes a top shelf with marine edges style lip and  
a lower shelf. When mounted on a stand with standard legs and properly leveled, the  
cooking surface should be approximately 36” from the floor.  
GRATES  
The charbroiler has a variety of optional grate accessories. Refer to your current catalog  
for pricing and availability.  
CAST DIAMOND GRATE  
S.S. DIAMOND GRATE  
STEEL ROD GRATE  
Thicker markings  
More caramelizing  
Low to moderate fat  
products  
Steak  
Hamburgers  
Low fat products  
Chicken  
C
Refer to the installation  
instructions provided with  
the condiment rail kit.  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Transcend Information Computer Drive JetFlash T3 User Manual
Tripp Lite Surge Protector PDU Rackmount Power Strips User Manual
Troy Bilt Lawn Mower TRU CUT 100 User Manual
ViewSonic Car Speaker VSACC27951 1 User Manual
ViewSonic Projector VS13646 User Manual
Vivitar Digital Camera T327 User Manual
Vizio Video Game Sound System S4220w E4 User Manual
Vornado Humidifier ULTRA1 User Manual
VTech Baby Toy 91 002924 000 User Manual
Vulcan Hart Electric Steamer ML 136056 User Manual