GENERALDIRECTIONS FOR INSTALLATION
Art.VX800N
Installation Instructions
In order to achieve the best results from the schematics described it is necessary to
install only original VIDEX equipment, strictly keeping to the items indicated on each
schematic and follow these General Directions for Installation:
MODELS:
!
The system must be installed according to national rules in force, in any case the
running of cables of any intercom unit must be carried out separately from the
mains;
VX800N-2
VX800N-2L
VX800N/F
VX800N/S
VX800N-3
VX800N-3L
Module 2 Relay
Module 2 Relay plus panel illumination
Stand alone unit 2 Relay. Flush mounting
Stand alone unit 2 Relay. Surface mounting
3 Relay
!
All multipair cables should be compliant to CW1308 specification (0.5mm twisted
pair telephone cable.
!
!
Cables for speech line and service should have a max resistance of 10W
Lock release wires should be doubled up (Lock release wires and power supply
wires should have a max resistance of 3W);
3 Relay plus panel illumination
!
The cable sizes above can be used for distances up to 50m. On distances above
50m the cable sizes should be increased to keep the overall resistance of the
cable below the RESISTANCES indicated above;
FEATURES
- Access control system with 2 codes and 2 Relay outputs (3 codes, 3
relays on VX800N-3.. version).
- Engineer’s code to enter into the “Programming Menu” ( from 4 to 8
digits).
!
!
Double check the connections before power up;
Power up the system then check all functions.
LOCK RELEASE BACK EMF PROTECTION
- Programming of the activation time of each relay from 1 up to 99 seconds
or latching.
- Possibility to activate relay 1 by shorting terminal ”SW1” to GND and
relay 2 by shorting terminal “SW2” to GND. Both relays will operate for
the programmed time ( this feature is not available on VX800N-3
version).
A capacitor must be fitted across the terminals on AC lock release (Fig.1A) and a
diode must be fitted across the terminals on a DC lock release (Fig.1B) to suppress
back EMF voltages.
Connect the components to the lock releases as shown in figures.
- Keypad gives an acoustic (buzzer) signal during the entering of codes
and a continuous melody for 4 or more seconds, according to the
number of mistakes (self protection).
- Keypad includes panel illumination (VX800N-..L only) and 2 LED’s to
show the following:
· Correct relay code (green LED on for 2 seconds).
· Red LED to indicate when in the “programming menu”.
- Contacts of the relays are available ( N.O and N.C) with 5A max
24Vac/dc.
Fig.1A
Fig.1B
BUZZER BACK EMF
When using intercoms with buzzer call (Art.924/926, SMART1/2, 3101/2, 3001/2 and
3021/2) add one 0,1uF capacitor between terminals 6 and 3.
- Power requirements: 12/24VAC/DC, 2VA.
- Working temperature: -10 +50°C
If help is required for installing or operating this unit please contact our
technical department on +39 0734 631669 (all countries) or +44 0191 224 3174
(UK).
OPERATION
Factory - Office
To use the system, type in the programmed code and press “ENTER” , the
green LED will illuminate and the relay will operate for the programmed
time.To cancel remain open time, type in the same code and press
“CLEAR”. If a wrong code is entered, a continuous melody will sound for 4
or more seconds, according to the number of mistakes.
VIDEX ELECTRONICS S.p.A. Via del lavoro,1 63020 MONTEGIBERTO (AP) - ITALY
Northern UK Office
VIDEX LTD Unit 4-7 Chillingam Industrial Estate Chapman Street NEWCASTLE UPON TYNE
Ne6 2XX
INITIALIZATION
PROGRAMMING(refer also to flow chart)
When the installation is concluded and carried out according to the wiring
diagram, power up the system and program it by following the “VX800
PROGRAMMING” Flow Chart.
> Enter “ENGINEER’S CODE”: first time type six times “1” (111111 factory
preset) and press ENTER (The red LED will illuminate).
> Confirm “ENGINEER’S CODE” (typing again the same) or type the new
code (4 to 8 digits) then press ENTER (Melody). Pressing twice the
ENTER button without changing the “ENGINEER’S CODE”, will exit
from the programming.
> Enter the code (4 to 8 digits) to enable “RELAY 1” (ACCESS 1) or re-
enter the existing code then press ENTER (Melody).
> Enter the “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5 seconds,
00= remain open time) or re-enter the existing time then press ENTER
(Melody).
> Enter the code (4 to 8 digits) to enable “RELAY 2” (ACCESS 2) or re-
enter the existing code then press ENTER (Melody).
> Enter the “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5 seconds,
00= remain open time) or re-enter the existing time then press ENTER
(Melody).
> Enter the code (4 to 8 digits) to enable “RELAY 3” (ACCESS 3 only for 3
relay models) or re-enter the existing code then press ENTER (Melody).
> Enter the “RELAY 3” (only for 3 relay models) operation time (2 digits 01
to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing
time then press ENTER (Melody).
FIRST TIME SIX TIMES
“111111” FACTORY
ENTER
“ENGINEER’S CODE”
1
PRESET
Press Enter
(Red LED will be
ON)
TYPE AGAIN SIX TIMES “1” OR
THE NEW ENGINEER’S CODE
4TO 8 DIGITS
CONFIRM OR CHANGE
“ENGINEER’S CODE”
Press Enter
(Melody)
CODE TO ENABLE
RELAY1
4TO 8 DIGITS
ENTER
“ACCESS 1 CODE”
Press Enter
(Melody)
TWO DIGITS (01TO 99)
I.E. 05=5 SECONDS
00= REMAIN OPEN
ENTER
“ACCESS 1 TIME”
Press Enter
(Melody)
CODE TO ENABLE
RELAY2
4TO 8 DIGITS
ENTER
“ACCESS 2 CODE”
> The system is ready to use (the red LED will be off).
INSTRUCTION TO RETURN SYSTEM TO PRESET ENGINEER’S
FACTORYCODE
Press Enter
(Melody)
> Turn off power to code lock.
> Keep “ENTER” button pressed while turning back on the power to the
code lock.
> Release “ENTER” button.
> The master code is now set at factory engineer’s code “111111” (six times
“1”).
> Proceed with programming for a new system.
ENTER
“ACCESS 2 TIME”
TWO DIGITS (01TO 99)
ONLY800-3 VERSION
ONLY800-3 VERSION
RED LED WILLBE OFF
Press Enter
(Melody)
ENTER
“ACCESS 3 CODE”
Press Enter
(Melody)
NOTES
> To switch off any relay while operating, type in the relevant code then
press the “CLEAR” button.
> To operate relays together, set the same code for each relay.
> If a wrong code is entered, the system will lock out for 5 seconds which
will increase each time a wrong code is entered. The system will operate
only when the correct code is entered.
ENTER
“ACCESS 3 TIME”
Press Enter
(Melody)
SYSTEM READY TO
USE