Transition Networks Network Card CPSMC0800 100 User Manual

Transition Networks  
CPSMC0800-100  
8-Slot PointSystem™ Chassis  
User’s Guide  
(revision A)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystem™ Chassis  
Table of Contents  
1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
1.1  
1.2  
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Unpacking the CPSMC0800-100 Equipment . . . . . . . . . . . . . . . . .5  
2
Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1  
Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1.1 Calculating Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1.2 Installing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .7  
2.1.3 Replacing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .8  
2.2  
Managment Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
2.2.1 Three Types of Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .9  
2.2.2 Installing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
2.2.3 Replacing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .11  
3
4
Powering the CPSMC0800-100 . . . . . . . . . . . . . . . . . . . . . . .12  
3.1  
3.2  
Primary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
Auxilliary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
CPSMC0800-100 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
4.1  
Installing the CPSMC0800-100 Chassis . . . . . . . . . . . . . . . . . . . .14  
4.1.1 Standard 19-Inch Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
4.1.2 Table-Top Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
4.2  
4.3  
4.4  
Cascade Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
Connecting the Slide-in-Modules to the Network . . . . . . . . . . . . .17  
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
5
6
SNMP Agent in the Management Module . . . . . . . . . . . . . . .19  
5.1  
5.2  
SNMP Hardware Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
SNMP Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
Fault Isolation and Correction . . . . . . . . . . . . . . . . . . . . . . . .21  
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22  
Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystem™ Chassis  
1
Introduction  
1.1  
Description  
The Transition Networks PointSystem™ CPSMC0800-100 is a 19-inch, rack-mount-  
able chassis for selected Transition Networks Media Converter Slide-In-Modules.  
The CPSMC0800-100 allows the network administrator to connect various copper  
and fiber-optic network media over protocols that include Ethernet, Fast  
Ethernet, DS3/E3, and OC-12. The CPSMC0800-100 provides installation space  
for up to eight (8) single-slot or four (4) dual-slot Media Converter Slide-in-Modules  
in the front of the unit.  
Management Module Installed Slide-In-Module  
Open Slot  
Power Inlet  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
The CPSMC0800-100 also comes equipped with an AC or DC power supply. An  
optional AC or DC power supply with Instant Fail Over operation is also available.  
The primary power supply is accessed through the Power Inlet on the front panel,  
while auxilliary power is accessed through the Auxilliary Power Inlet, located on the  
back panel.  
Auxilliary Power Inlet  
Four fans, two for the power supplies and two for the Slide-In-Modules, help remove  
heat from the chassis.  
With installed PointSystem™ Management Module(s) (TN part number CPSMM-  
120, -200, or -210), the CPSMC0800-100 can be managed and monitored via:  
An SNMP application such as Transition Networks FocalPoint™ management  
software installed at a remote Network Management Station (NMS).  
A remote Web browser.  
A command-line interface (CLI) at an attached terminal.  
A command-line-interface (CLI) at a remote Telnet connection.  
The management features include:  
Power control (slot on, slot off, in rush limit) for each individual slot.  
Internal temperature monitor.  
Fan failure monitor.  
Chassis power consumption monitor.  
Power supply type identification.  
Power supply condition monitor.  
Fail-over power detection.  
The Management Modules also make it possible to control up to eight (8) cascaded  
CPSMC0800-100 chassis, which can accomodate up to 55 installed Media  
Converter Slide-in-Modules.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystem™ Chassis  
2.1  
Unpacking the CPSMC0800-100 Equipment  
Use the following list to verify the shipment:  
Item  
Part Number  
8-Slot chassis with AC power supply  
8-Slot chassis with DC power supply  
Power Cord  
CPSMC0800-100  
CPSMC0810-100  
(varies by country)  
External AC Power Supply  
CPSMP-180 (optional)  
CPSMP-190 (optional)  
CPSMM-100 (optional)  
CPSMM-200 (optional)  
FPS (provided with CPSMM-200)  
CPSMM-210 (optional)  
6026 (optional)  
External DC Power Supply  
1-slot Master Management Module  
2-slot Master Management Module  
FocalPoint™ Software Disk  
Expansion Management Module  
Management Module Cascade Connector  
Rack Mount Ears  
CPSRE-238 (optional)  
Selectable Media Converter Slide-in-Module(s) (various P/N) - (optional)  
Users Guide 33270  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2
Slide-in-Modules  
2.1  
Media Converter Slide-in-Modules  
Transition Networks Media Converter Slide-in-Modules, installed in slots at the front  
of the chassis, allow the network administrator to connect various copper and fiber-  
optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3,  
NOTE: Refer to the documentation that comes with each Media Converter Slide-in-  
Module for cable, connector, and LED indicator information specific to that Media  
Converter Slide-in-Module.  
2.1.1  
Calculating the Power Consumption  
CAUTION: Before installing the Media Converter Slide-in-Modules, refer to the  
power consumption data for each individual Media Converter Slide-in-Module  
(provided in the User’s Guide shipped with each Media Converter Slide-in-  
Module). The combined power consumption of all devices must not exceed the  
available power supply. Failure to observe this caution could result in diminishing  
system reliability.  
In other words, the combined wattage of the CPSMC0800-100 8-Slot chassis plus  
all Slide-In-Modules must be less than the available power.  
Contact Transition Networks Tech Support to ensure the power requirements for  
your specific application do not exceed the available power.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2.1.2  
Installing the Media Converter Slide-in-Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge precau-  
tions when installing the Media Converter Slide-in-Module(s) into the chassis.  
Failure to observe this caution could result in damage to, and subsequent failure  
of, the Media Converter Slide-in-Module(s).  
NOTE: Media Converter Slide-in-Modules can be installed in any installation slot,  
in any order.  
To install the Media Converter Slide-in-Module into the CPSMC0800-100 8-Slot  
chassis:  
1. Remove the Media Converter Slide-in-Module protective plate from the instal-  
lation slot by removing the one (1) screw that secures the plate to the front of  
the chassis.  
NOTE: If the Slide-in-Module requires two slots, remove the protective plates  
from two (2) adjacent installation slots.  
2. Align the Media Converter Slide-in-Module with the chassis installation slot so  
that the panel fastener screw is at the left of the Media Converter Slide-in-  
Module.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Multimode  
Singlemode  
Panel Fastener Screw  
3. Carefully slide the Media Converter Slide-in-Module into the installation slot.  
NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against  
the back of the chassis.  
4. Install the Media Converter Slide-in-Module by carefully rotating the attached  
panel fastener screw clockwise to secure the Media Converter Slide-in-Module  
to the chassis.  
5. Repeat steps 1 through 4 for additional Media Converter Slide-in-Module(s).  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2.2.3  
Replacing the Media Converter Slide-in-Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge precau-  
tions when replacing Media Converter Slide-in-Module(s). Failure to observe this  
caution could result in damage to, and subsequent failure of, the Media Converter  
Slide-in-Module(s).  
NOTE: The Media Converter Slide-in-Modules are hot-swappable.  
To replace a Media Converter Slide-in-Module:  
1. Remove the Media Converter Slide-in-Module to be replaced by loosening the  
one (1) screw that secures the Slide-in-Module to the CPSMC0800-100 chassis  
front. Slide the Media Converter Slide-In-Module from the CPSMC0800-100  
chassis.  
2. Align the replacement Media Converter Slide-in-Module with the chassis instal-  
lation slot so that the panel fastener screw is to the left.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Multimode  
Singlemode  
Panel Fastener Screw  
3. Carefully slide the replacement Media Converter Slide-in-Module into the  
installation slot.  
NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against  
the back of the chassis.  
4. Install the replacement Media Converter Slide-in-Module by carefully rotating  
the attached panel fastener screw clockwise to secure the Media Converter  
Slide-in-Module to the chassis.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2.2  
Management Modules  
Optional network management is provided by SNMP software embedded in  
Transition Networks PointSystemManagement Module(s) that can be installed in  
the CPSMC0800-100 8-Slot chassis.  
Transition Networks provides two such modules:  
CPSMM-120 Single-Slot Master Management Module.  
CPSMM-200 Dual-Slot Master Management Module.  
Along with an additional expansion module:  
CPSMM-210 Single Slot Expansion Management Module  
2.2.1  
Three Types of Managment Modules  
TX PWR  
CPSMM-120 Single-Slot Master Managment Module  
RX LNK  
RESET  
The optional CPSMM-120 Single-Slot Master Managment Module can  
be installed to enable network managment of a single CPSMC0800-100  
8-Slot chassis .  
Refer to the CPSMM-120 User Guide for more information on the  
CPSMM-120 Single-Slot Master Management Module.  
CPSMM120  
CPSMM-200 Dual-Slot Master Management Module  
The optional CPSMM-200 Dual-Slot Master Managment Module  
can also be installed in the CPSMC0800-100 8-Slot chassis to  
enable network managment.  
TX PWR  
RX LNK  
RESET  
This module has all of the features of the CPSMM-120 plus a pair  
of cascade ports, which allow multiple PointSystem chassis to  
be connected. See section 4.3 Cascade Option for details on  
connecting multiple chassis.  
Note also that this module requires two adjacent slots in the  
CPSMM200  
CPSMC0800-100 8-Slot chassis for installation.  
Refer to the CPSMM-200/-210 User Guide for more information on the CPSMM-200  
Dual-Slot Master Management Module.  
CPSMM-210 Single-Slot Expansion Management Module  
The CPSMM-210 is used with the CPSMM-200 to connect up to eight (8)  
PointSystem™chassis into one managable stack. See section 4.3 Cascade  
RESET  
Option for details.  
Pwr  
INIT  
TERM  
Refer to the CPSMM-200/-210 User Guide for more information on the  
CPSMM-210 Single-Slot Expansion Management Module.  
12C-1  
12C  
CPSMM210  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2.2.2  
Installing the Managment Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge precau-  
tions when installing the Management Module(s) in the 8-Slot chassis. Failure to  
observe this caution could result in damage to, and subsequent failure of, the  
Management Module.  
Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) in the  
primary managed CPSMC0800-100 8-Slot chassis.  
If several PointSystem™chassis are to be connected in a cascade fashion (see sec-  
tion 4.3 Cascade Option):  
Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) into  
the primary managed CPSMC0800-100 8-Slot chassis.  
Install one (1) Master Management Module (CPSMM-200) or one (1) Expansion  
Management Module (CPSMM-210) in any secondary managed CPSMC0800-  
100 8-Slot chassis.  
NOTE: Though the Management Module(s) can be installed in any PointSystem™  
chassis slot, use of the left-most installation slot(s) for installing the Management  
Module(s) is recommended in order to keep the cascading cables separate from the  
network cables connected to the installed on Media Converter Slide-In-Modules.  
To install a Management Module:  
1a. CPSMM-200 Dual-Slot Master Management Module:  
Remove two (2) Management Module protective plates from two (2) installation  
slots at the far-left position by removing the one (1) screw that secures each pro-  
tective plate to the PointSystem™ chassis.  
1b. CPSMM-120 Single-Slot Master Management Module OR  
CPSMM-210 Single-Slot Expansion Management Module:  
Remove one (1) Management Module protective plate from one (1) installation  
slot at the far-left position by removing the one (1) screw that secures the pro-  
tective plate to the PointSystem™ chassis.  
2. Align the Management Module with the PointSystem™ chassis installation slot  
so that the panel fastener screw is to the left of the Management Module.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
DB-9  
CPSMC-0800  
8-Slot Chassis  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
10BASE-T  
Panel Fastener Screw  
3. Carefully slide the Management Module into the installation slot, aligning the  
Management Module with the installation guides.  
NOTE: Ensure that Management Module is firmly seated against backplane.  
4. Rotate the attached panel fastener screw clockwise to secure the Management  
Module to the PointSystem™ chassis.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
2.2.3  
Replacing the Mangement Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge precau-  
tions when replacing Media Converter Slide-in-Module(s). Failure to observe this  
caution could result in damage to, and subsequent failure of, the Management  
Module(s).  
NOTE: The Managment Modules are NOT hot-swappable.  
To replace a Managment Module:  
1. Remove the Managment Module to be replaced by loosening the one (1) screw  
that secures the Managment Module to the CPSMC0800-100 chassis front.  
Slide the Management Module from the CPSMC0800-100 chassis.  
2. Align the replacement Mangement Module with the installation slot so that the  
panel fastener screw is at the top.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
DB-9  
CPSMC-0800  
8-Slot Chassis  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
10BASE-T  
Panel Fastener Screw  
3. Carefully slide the replacement Managment Module into the installation slot.  
NOTE: Ensure that the Managment Module is firmly seated against the back of  
the chassis.  
4. Install the replacement Managment Module by carefully rotating the attached  
panel fastener screw clockwise to secure the Managment Module to the  
chassis.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
3
Powering the CPSMC0800-100  
The CPSMC0800-100 chassis can be powered through an AC or DC Power Supply.  
An optional auxilliary power supply, with Instant Fail Over protections, is also avail-  
able.  
NOTE: The CPSMC0800-100 8-Slot chassis does not have an ON/OFF switch.  
Power up the chassis by connecting the power supply.  
Power-down the chassis by disconnecting power supply.  
WARNING: THE AC AND DC POWER SUPPLIES CONTAIN NO USER-SERVICA-  
BLE PARTS. DO NOT ATTEMPT TO SERVICE EITHER POWER SUPPLY. FAILURE  
TO OBSERVE THIS CAUTION COULD RESULT IN EQUIPMENT DAMAGE  
AND/OR PERSONAL INJURY OR DEATH.  
NOTE: Contact Technical Support for any questions concerning power supply.  
3.1  
Primary Power Supply  
The CPSMC0800-100 includes an internal power supply, which is accessed through  
a power inlet on the front panel. The power cord is included.  
To power the CPSMM0800-100 8-Slot chassis through the Primary Power Supply:  
1. Connect the female end of the power cord to the Power Inlet on the front panel  
of the chassis.  
2. Plug the male end of the power cord into the correct voltage rack or wall sock-  
et.  
3. Verify that the 8-Slot chassis is powered by observing the illuminated Power  
LEDs on the Slide-in-Modules and by the fan operation.  
Power Inlet  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Power Cord  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
3.2  
Auxilliary Power Supply  
The CPSMC0800-100 can also be supplied with auxilliary power through the  
Auxilliary Power Inlet, located on the back panel. The External Power Converter and  
additional power cord are sold separately.  
To power the CPSMM0800-100 8-Slot chassis through the Auxilliary Power Supply:  
1. Connect the female end of the External Power Converter to the Auxilliary Power  
Inlet on the back of the 8-Slot chassis.  
2. Connect the female end of the power cord to the male end of the External Power  
Converter.  
3. Plug the male end of the power cord into the correct voltage AC rack or wall  
socket.  
4. Verify that the chassis is powered by observing the illuminated Power LEDs on  
the Slide-in-Modules and by the fan operation.  
Auxilliary Power Inlet  
External Power  
Converter  
Power Cord  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
4
CPSMC0800-100 Chassis  
4.1  
Installing the CPSMC0800-100 Chassis  
The CPSMC0800-100 can be installed in a standard 19-inch rack or on a table,  
shelf, or other stable surface.  
4.1.1  
Standard 19-inch Rack Installation  
NOTE: The maximum recommended ambient temperature (Tmra) for the 8-Slot  
chassis is 40°C. If the 8-Slot chassis is installed in a closed or mult-unit rack assem-  
bly, the operating ambient temperature of the the rack environment may be greater  
than room ambient. Consideration should be given to installing the 8-Slot chassis  
in an environment compatible with the Tmra.  
CAUTION: Installation of the chassis in a rack should be such that the amount of  
air flow required for safe operation of the equipment is not compromised .  
The 8-Slot chassis is designed so that the installation brackets can be installed to  
align the chassis either flush against the front or back edge of the rack or recessed  
from the front or back edge of the rack.  
Recessed Alignment  
at front  
Flush Alignment  
at front  
Flush Alignment  
at back  
Recessed Alignment  
at back  
WARNING: SELECT MOUNTING BRACKET LOCATIONS ONTHE CHASSISTHAT  
WILL KEEP THE CHASSIS BALANCED WHEN MOUNTED IN THE RACK. FAILURE  
TO OBSERVE THIS WARNING COULD ALLOW THE CHASSIS TO FALL, RESULT-  
ING IN EQUIPMENT DAMAGE AND/OR POSSIBLE INJURY TO PERSONNEL.  
CAUTION: Consideration should be given to the connection of the chassis to the  
supply circuit and the effect that overloading of the circuits might have on over-  
current protection and supply wiring. Appropriate consideration of equipment  
nameplates should be used when addressing this concern.  
CAUTION: Reliable earthing of rack-mounted equipment should be maintained.  
Particular attention should be given to supply connections other than direct con-  
nections to the branch circuit (e.g., use of power strips).  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
To install the CPSMC0800-100 8-Slot chassis into a standard 19-inch rack:  
1. Determine the preferred alignment of the 8-Slot chassis in the rack.  
NOTE: Installation bracket mounting screws are provided. Rackmount screws  
and clip nuts are NOT provided.  
2. Locate six (6) installation bracket mounting screws (provided) for each chassis  
to be installed.  
WARNING: Mount the chassis evenly and securely onto the rack. Failure to  
observe this warning could allow the chassis to fall, resulting in equipment  
damage and/or possible injury to personnel.  
3. Align the universal mounting bracket in the selected position against the side of  
the chassis so that the chassis installation holes are visible through the univer-  
sal bracket installation holes.  
4. Using a Phillips screwdriver, install the three (3) screws through the mounting  
bracket into the installation holes on side of the chassis.  
Step 4:  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Singlemode  
Multimode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Singlemode  
Multimode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
8-Slot Chassis  
10BASE-T  
10/100TX  
5. Repeat steps 3 and 4 for the second mounting bracket.  
6. Locate four (4) screws (not provided) and optional clip-nuts (not provided) for  
each chassis to be installed.  
7. Carefully align the chassis at a secure and level position between the 19-inch  
site rack mounting rails.  
8. Install two (2) screws through the right bracket into the right mounting rail and  
two (2) screws through the left bracket into the left mounting rail, using the clip  
nuts to secure, if necessary.  
DB-9  
Mpls, MN 55344  
Step 8:  
Input Power:  
10-240 AC  
1
V
Singlemode  
Multimode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
I
N
I
T
1
2
C
12C-1  
Singlemode  
Multimode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
8-Slot Chassis  
10BASE-T  
10/100TX  
4.1.2  
Table-Top Installation  
The CPSMC0800-100 8-slot chassis is shipped with four (4) rubber feet for optional  
installation on a table or other flat, stable surface in a well-ventilated area. If table-  
top installation is desired, remove the rubber feet from the card and place one at  
each of the four corners on the bottom of the chassis.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
4.2  
Cascade Option  
The Management Module cascade option allows the network administrator to con-  
nect up to eight (8) CPSMC0800-100 8-Slot chassis into one manageable stack, pro-  
viding a single management source for up to 55 installed Media Converter devices.  
To create the cascade option, the CPSMM-200 Dual Slot Master Management  
Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot  
Expansion Management Module is installed in each subsequent chassis.  
The CPSMM-200  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Management Module is  
installed in the first  
chassis in the series  
Multimode  
Multimode  
Multimode  
Multimode  
Singlemode  
Singlemode  
Singlemode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OU
10/100SX  
10/100SX  
10/100SX  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
10/100TX  
10/100TX  
10/100TX  
8-Slot Chassis  
The CPSMM-210  
Management Module is  
installed in each  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
subsequent chassis  
Multimode  
Singlemode  
CPSMC-0800  
8-Slot Chassis  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
Multimode  
Singlemode  
CPSMC-0800  
8-Slot Chassis  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
Multimode  
Singlemode  
CPSMC-0800  
8-Slot Chassis  
An alternative setup involves installing two CPSMC-200 Dual-Slot Master  
Management Modules into two adjacent chassis chassis for redundant management.  
The CPSMM-200  
Management Module is  
installed in the first  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
chassis in the series  
Another CPSMM-200  
Managment Module is  
installed in the next  
chassis as a backup  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
Multimode  
Singlemode  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
To cascade two or more CPSMC0800-100 8-Slot chassis:  
1. Locate one (1) Transition Networks CPSMC0800-100 Management Module cas-  
cade cable (with RJ-45 connectors installed at both ends) for each set of two (2)  
chassis to be cascaded.  
NOTE: Transition Networks Management Module cascade cables are one (1)  
meter long. Ensure that the chassis are installed within one (1) meter of each  
other.  
2. At the first chassis in the series: Plug the RJ-45 connector at one end of the cas-  
cade cable into the Management Modules RJ-45 port labeled “OUTPUT”.  
3. At the next chassis in the series: Plug the RJ-45 connector at the other end of  
the cascade cable into the Management Modules RJ-45 port labeled “INPUT”.  
4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the  
cascade cable into the Management Modules RJ-45 port labeled “OUTPUT”.  
5. At the next chassis in the series: Plug the RJ-45 connector at the other end of  
the cascade cable into the Management Modules RJ-45 port labeled “INPUT”.  
6. Repeat steps 4 and 5 until all chassis have been connected.  
4.3  
Connecting the Slide-in-Modules to the Network  
Once the CPSMC0800-100 chassis has been installed, the Media Converter Slide-  
in-Modules may be connected to the network.  
CAUTION: Connect input/output network cables ONLY to Media Converter Slide-  
In-Module connectors within the same network protocol (such as Ethernet-to-  
Ethernet, Fast Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this cau-  
tion will cause data transfer to fail.  
Refer to Users Guides included with the Media Converter Slide-In-Modules for  
cabling specifications and instructions.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Check the individual User's Guides for specific information on  
how to connect each Slide-in-Module to the network.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
4.4  
Operation  
Daily operation of the CPSMC0800-100 8-Slot chassis requires no network admin-  
istrator activity except for the occasional monitoring of the status LED indicators on  
the installed Media Converter Slide-In-Modules.  
Each Media Converter Slide-in-Module and each Management Slide-in-Module has  
one or more LED indicators to help monitor the CPSMC0800-100 PointSystem™  
chassis network.  
Refer to the Users Guide included with each Transition Networks Slide-in-Module  
to interpret the LED indicators on the Managment and Media Converter modules.  
LED Indicators on the Management Module and Slide-in-Modules  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
5
SNMP Agent in the Management Module  
Both Management Modules (CPSMM-120 and (CPSMM-200) have an SNMP  
(Simple Network Managment Protocol) Agent installed in the module that allows  
remote managment of networked devices.  
The SNMP agent includes the Transition Networks PointSystem™ Command Line  
Interface (CLI) and an embedded Telnet server.  
These tools allow the network adminsitrator to configure and manage the  
CPSMC0800-100 8-Slot from an attached terminal or from a remote, networked  
computer.  
In addition, Transition Networks FocalPoint™ software can be installed in the net-  
worked computer to provide a graphical user interface to monitor the Conversion  
Center.  
5.1  
SNMP Hardware Connections  
The SNMP software can be accessed either through the Management Module’s DB-  
9 serial port or through the RJ-45 Ethernetport.  
RJ-45 Ethernet Port  
TX PWR  
TX PWR  
X LNK  
RX LNK  
RESET  
RESET  
DB-9 Serial Port  
CPSMM200  
CPSMM120  
CPSMM-200  
CPSMM-120  
DB-9 Serial Port  
The DB-9 serial port allows the network administrator to configure and manage the  
CPSMC0800-100 8-Slot chassis using the SNMP Command-Line Interface (CLI) at  
an attached terminal or terminal emulator.  
Use a null modem cable to attach a terminal to the DB-9 serial port on the  
Management Module as shown.  
Attached terminal or terminal emulator  
connected to the DB-9 serial port  
via null modem cable.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
RJ-45 Ethernet™ Port  
The RJ-45 Ethernet™ Port allows the network administrator to manage the  
CPSMC1800-100 8-Slot chassis via a remote Network Management Station (NMS)  
in one of two ways:  
1. Using the Transition Networks FocalPoint™ graphical user interface.  
2. Using a remote Telnet connection.  
Use an RJ-45 network cable to attach a terminal (via a network hub or switch) to the  
RJ-45 Ethernet™port on the Management Module as shown.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
Remote Telnet connection OR  
Remote NMS with an SNMP application  
Network hub or switch connected  
to the RJ-45 Ethernet port.  
NOTE: To manage the PointSystem™ chassis via a remote NMS, both the RJ-45  
Ethernet™ port and the NMS must be connected to a network with Internet accesi-  
bility.  
5.2  
SNMP Software  
The SNMP software is described in a separate manual available from Transition  
Networks.  
Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
6
Fault Isolation and Correction  
1. Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated;  
AND/OR are the fans operating?  
YES  
The chassis is receiving power. Proceed to the next step.  
NO  
Ensure all power supply cables for proper connection.  
Ensure the AC receptacle on the wall is supplying power.  
If the fuse for the AC receptacle on the wall blows repeatedly, have the AC  
receptacle inspected by a qualified electrician.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
2. Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated; but  
are the fans NOT operating?  
YES  
The chassis is receiving power. Proceed to the next step.  
NO  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
3. For the Management Modules (CPSMM120, CPSMM200, CPSMM210), are  
ANY of the POWER LEDs NOT illuminated?  
NO  
All Managment Modules are receiving power. Proceed to the next step.  
YES  
For those Management Modules where the POWER LED is NOT illuminated:  
Ensure the Management Module is firmly seated in the slot.  
Press the RESET button on the Managment Module.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
4. For the remaining Slide-in-Modules, are ANY of the POWER LEDs NOT illumi-  
nated?  
NO  
All Slide-in-Modules are receiving power. Proceed to the next step.  
YES  
For those Slide-in-Modules where the POWER LED is NOT illuminated:  
Ensure the Slide-in-Module is firmly seated in the slot.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
5. To determine if a fault is due to a software problem, consult the “Fault  
Isolation and Correction” section of the SNMP software manual available from  
Transition Networks.  
6. To determine if a fault is due to an individual Managment Module or Slide-in-  
Module, consult the “Fault Isolation and Correction” section of the User  
Guide for that particular Module.  
7. If none of the solutions listed in this section resolves the problem, contact  
Technical Support: 1-800-260-1312, International: 00-1-952-941-7600.  
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
Technical Specifications  
For use with Transition Networks Model CPSMC0800-100 or equivalent.  
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the  
date of manufacture.  
Dimensions  
17 x 10.4 x 1.8 inches (432 x 264 x 46 mm)  
8 lbs. (3.6 kg)  
Shipping Weight  
Power Input  
100-240VAC, 50/60Hz, 18-72VDC  
Power Consumption  
60 Watts*  
*Refer to the power consumption data for each individual Media Converter Slide-in-Module (provided  
in the Users Guide shipped with the Media Converter) to determine optimum site configuration.  
MTBF (Mean Time Before Failure)  
without fans  
MIL217F2 V5.0 (hrs) Bellcore7 V5.0 (hrs)  
43,277  
22,972  
114,896  
61,715  
with three (3) fans  
Environment  
Tmra*:  
0 to 40°C (32° to 104°F )  
-40 to 80°C (-40 to 176°F )  
5 to 95%, non condensing  
0 to 10,000 feet  
Storage Temperature:  
Humidity  
Altitude  
*Manufacturers rated ambient temperature. Refer to the power consumption data for EACH model  
Media Converter Slide-in-Module (provided in User’s Guide shipped with Media Converter Slide-in-  
Module) to determine optimum site configuration.  
Compliance  
Warranty  
EN 55022 Class A; EN 55024; FCC Class A; UL Listed, CE Mark  
Lifetime  
CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly  
With Optical Instruments.  
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified  
herein may result in hazardous radiation exposure.  
DECLARATION OF CONFORMITY  
Name of Mfg:  
Transition Networks  
6475 City West Parkway, Minneapolis MN 55344 USA  
Model:  
PointSystemChassis  
Part Number:  
Regulation:  
CPSMC0800-100, CPSMC0810-100  
EMC Directive 89/336/EEC  
Purpose: To declare that the PointSystemChassis to which this declaration refers  
is in conformity with the following standards.  
EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; UL 1950; 21 CFR subpart J  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
_April 1, 2003_____  
Stephen Anderson, Vice-President of Engineering  
Date  
Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
Cable Specifications  
Null Modem Cable  
The Null Modem Cable is used for connecting a terminal or terminal emulator to  
the Management Modules DB-9 connecdtor to access the command-line interface.  
The table below shows the pin assignments for the DB9 cable.  
Function  
Mnemonic  
CD  
RXD  
TXD  
DTR  
GND  
DSR  
Pin  
1
2
3
4
5
6
7
8
Carrier Detect  
Receive Data  
Transmit Data  
Data Terminal Ready  
Signal Ground  
Data Set Ready  
Request To Send  
Clear To Send  
RTS  
CTS  
RJ-45 Cable  
Category 5:  
Gauge:  
24 to 22 AWG  
Attenuation:  
Maximum Cable Distance:  
22.0 dB /100m @ 100 MHz  
100 meters  
• Straight-Through OR Crossover cable may be used.  
• Shielded Twisted-Pair(STP) OR Unshielded Twisted-Pair(UTP) may be used.  
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet™ network.  
• Use only dedicated wire pairs for the active pins:  
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)  
• Do not use flat or silver satin wire.  
Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
Contact Us  
Technical Support  
Technical support is avialable 7:00 AM - 6:00 PM CST (GMT -6:00)  
United States: 1-800-260-1312  
International: 00-1-952-941-7600  
Transition Now  
Chat live wia the Web with a Transition Networks Technical Support Specialist.  
Log onto www.transition.com and click the Transition Now link.  
Web-Based Seminars  
Transition Networks provides 12-16 seminars per month via live web-based train-  
ing.  
Log onto www.transition.com and click the Learning Center link.  
E-Mail  
Ask a question anytime by sending an e-mail message to our technical support staff.  
Address  
Transition Networks  
6475 City West Parkway  
Minneapolis, MN 55344, USA  
telephone: 952-941-7600  
toll free:  
fax:  
800-526-9267  
952-941-2322  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
Warranty  
Limited Lifetime Warranty  
Effective for Products Shipped May 1, 1999 and After. Every Transition Networks'  
labeled product purchased after May 1, 1999 will be free from defects in material  
and workmanship for its lifetime. This warranty covers the original user only and is  
not transferable.  
This warranty does not cover damage from accident, acts of God, neglect, contam-  
ination, misuse or abnormal conditions of operation or handling, including over-  
voltage failures caused by use outside of the product's specified rating, or normal  
wear and tear of mechanical components. If the user is unsure about the proper  
means of installing or using the equipment, contact Transition Networks' free tech-  
nical support services.  
To establish original ownership and provide date of purchase, please complete and  
return the registration card accompanying the product or register the product on-  
line on our product registration page.  
Transition Networks will, at its option:  
Repair the defective product to functional specification at no charge,  
Replace the product with an equivalent functional product, or  
Refund the purchase price of a defective product.  
To return a defective product for warranty coverage, contact Transition Networks'  
technical support department for a return authorization number. Transition's techni-  
cal support department can be reached through any of the following means:  
During regular business hours Monday-Friday, 7 AM – 6 PM CST (- 6:00 GMT),  
Contact Tech Support via:  
tel 800-260-1312 x 200 or 952-941-7600 x 200  
fax 952-941-2322  
live web chat: Transition NOW  
Any Other Time:  
voice mail 800-260-1312 x 579 or 952-941-7600 x 579  
All messages will be answered within one hour.  
Send the defective product postage and insurance prepaid to the following address:  
CSI Material Management Center  
c/o Transition Networks  
508 Industrial Drive  
Waconia, MN 55387 USA  
Attn: RETURNS DEPT: CRA/RMA # ___________  
Failure to properly protect the product during shipping may void this warranty. The  
return authorization number must be written on the outside of the carton to ensure  
its acceptance. We cannot accept delivery of any equipment that is sent to us with-  
out a CRA or RMA number.  
The customer must pay for the non-compliant product(s) return transportation costs  
to Transition Networks for evaluation of said product(s) for repair or replacement.  
Transition Networks will pay for the shipping of the repaired or replaced in-warran-  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC0800-100 PointSystemChassis  
ty product(s) back to the customer (any and all customs charges, tariffs, or/and taxes  
are the customer's responsibility).  
Before making any non-warranty repair, Transition Networks requires a $200.00  
charge plus actual shipping costs to and from the customer. If the repair is greater  
than $200.00, an estimate is issued to the customer for authorization of repair. If no  
authorization is obtained, or the product is deemed not repairable, Transition  
Networks will retain the $200.00 service charge and return the product to the cus-  
tomer not repaired. Non-warranted products that are repaired by Transition  
Networks for a fee will carry a 180-day limited warranty. All warranty claims are  
subject to the restrictions and conventions set forth by this document.  
Transition Networks reserves the right to charge for all testing and shipping incurred,  
if after testing, a return is classified as "No Problem Found."  
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS  
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. Transition  
NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING  
FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHO-  
RIZED TO EXTEND ANY DIFFERENT WARRANTY ON TRANSITION NETWORKS'  
BEHALF.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toshiba Projector TDP P8 User Manual
Toshiba Scanner EO1 19028B User Manual
Toyota Automobile 2011 User Manual
Transcend Information Computer Drive TS0GSJ25P User Manual
Triarch Indoor Furnishings 31020 2 User Manual
Tripp Lite TV Cables S456 010 User Manual
Vandersteen Audio Portable Speaker VCC 5 User Manual
Vermont Casting Ventilation Hood BHDT36 User Manual
Victory Refrigeration Refrigerator VPT 119 User Manual
Vulcan Hart Griddle MGG24 User Manual