CONTENTS
1. INTRODUCTION ...................................................... 4
1.1 General Discription.............................................................................4
1.2 Key Features.......................................................................................5
1.3 Use Power City to ...............................................................................5
1.4 Storage Location.................................................................................6
2. USE AS A JUMPSTART SYSTEM .....................................
6
2.1 Jumpstart Warnings ............................................................................5
3. USE AS A 12 VOLT DC PORTABLE POWER SUPPLY ........
4. POWER INVERTER........................................................
7
7
4.1 Inverter Operations.............................................................................8
4.2 Principles of Operations ......................................................................8
4.3 Connecting Inverter to Power Source Away from Unit ...........................8
4.3.1 Procedure for connecting inverter to remote DC Source .....................9
4.3.2 Operating Time ...............................................................................9
4.4 Powering an AC load .........................................................................9
4.5 Placement of the Power Inverter ...........................................................10
4.6 Operating Tips ...................................................................................10
4.7 Inverter fuse replacement ....................................................................11
5. COMPRESSOR/TIRE INFLATOR ..................................... 11
5.1 Compressor Use .................................................................................11
5.2 Warnings ...........................................................................................11
5.3 Tire Inflation or products with a valve stem...........................................12
5.4 Inflate other articles (without valve stem) ..............................................12
5.5 Typical inflation times..........................................................................12
6. LANTERN USE.............................................................. 12
6.1 Lantern Operation on main unit...........................................................12
6.2 Lantern Operation detached from main unit .........................................13
6.2.1 Lantern Operation from DC source ...................................................13
6.2.2 Lantern Operation 110 Volt with AC recharge adapter......................13
6.3 Lamp Replacement ..............................................................................14
7. RECHARGING POWER CITY’S BATTERY .................... 14
7.1 AC Recharging ...................................................................................15
7.2 DC Recharge ......................................................................................15,16
7.3 Alternate DC Recharge .......................................................................16
7.4 Simultaneous DC Recharge and Inverter Operation ..............................16
8. MAINTENANCE/REPLACEMENT PARTS .................... 16
9. BATTERY DISPOSAL AND WARNINGS ...................... 16
10.SPECIFICATIONS...................................................... 17
11.WARRANTIES .......................................................... 18,19
Download from Www.Somanuals.com. All Manuals Search And Download.
3
1.
INTRODUCTION
Congratulations on selecting the Vector Power City® Multi-Function AC/DC Power System.
Power City is an advanced power and jumpstart system with unique features that set it far
above the value and utility of ordinary jump starters. It supplies AC for 110 volt appliances to
200 watts, and DC for 12 volt appliances to 23 amps. It can jumpstart any vehicle with a
standard 12 volt DC electrical system: boat, truck, car, airplane, RV, personal watercraft,
snowmobile, tractor, etc. See Figure 1.
2
3
FIGURE 1
1. INVERTER COVER
2. RETRACTED HANDLE
3. LANTERN ASSEMBLY
LATCH
12
1
4. LANTERN ON/OFF
SWITCH
4
5. 12V ACCESSORY
SOCKETS
11
6. MAIN POWER
SAFETY SWITCH
9
7. CHARGE STATUS
DISPLAY
8. CHARGE STATUS
PUSHBUTTON
10
9. NEG. (BLACK) CLAMP
10. POWER INVERTER
11. COMPRESSOR GAUGE
12. POS. (RED) CLAMP
7
8
5
6
1.1
GENERAL DISCRIPTION
This advanced design is ideal for emergencies and can also enhance your fun by powering
appliances on the road and at the campsite. Be sure to read and understand all WARNINGS and
CAUTIONS before using this product. Please read this guide carefully before use to ensure optimum
performance and avoid damage to the system or items that you are using it with.
Power City® has several exclusive features that set it apart from other similar devices.
Primarily, it includes a special, patented, built-in mounting for a supplied, removable 12 VDC to 110
volt AC power inverter. This allows you to operate 110 volt AC devices to 200 watts, while still
maintaining the Jump Starter's one-piece, compact styling. When the inverter is
removed from the Main Unit it can be fully powered from any accessory socket that can provide up
to 23 amperes at 12 VDC.
A removable Lantern operates from Power City’s self-contained battery. It can be operated attached
to the Main Unit or removed from the Main Unit. Away from the Main Unit, the Lantern is powered
using an extension cord attached to the Inverter Power Cable. This feature is
invaluable when it becomes necessary to locate battery terminals while preparing to jumpstart a
dead battery in the dark, changing a tire, etc.
Power City is also ideal to power 12 volt DC cordless, portable, rechargeable appliances with
ratings up to 23 amperes. For information about Vector appliances, contact Vector Customer Sup-
port for the location of the nearest retailer.
The unit has an easy-to-read, series of LEDs (Light Emitting Diodes) arranged as a Charge Status
Display that shows when the unit is fully charged or the level of charge in the battery (from Low to
Full). The Charge Status Display activates whenever the Charge Status Push-button is pressed or
automatically during AC Recharge operations. Two 12 volt DC cigarette lighter-type sockets are
provided for use with appliances that can operate from a cigarette lighter type accessory socket.
Note that all exposed electrical sockets recharge ports have covers that help keep out dirt, dust and
moisture. All covers must be open for use; closed after use.
Another feature is the high pressure, self-contained Air Compressor. This Compressor allows quick
inflation of tires, sports balls and other small inflatables. An easy to read analog pressure gauge
allows accurate pressure readings, so there’s no guesswork about critical tire pressures. Now there
is no excuse for driving on under- or over-inflated tires. Three different types of adapter nozzles
allow for easy connection to all popular inflatables. A Compressor On/Off slide switch located
between the jumpstart clamps controls operation of the Compressor. The Air Compressor Hose and
Connector Nozzle are stored on the back of the unit. See Figure 3.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
5
4
FIGURE 2
1. NEGATIVE (BLACK)
CLAMP
2. AIR COMPRESSOR
ON/OFF SWITCH
3
3. AC RECHARGE PORT
4. POSITIVE (RED) CLAMP
5. AIR COMPRESSOR
PRESSURE GAUGE
2
6. 110 VOLT AC CHARGER
1
6
1.2
KEY FEATURES
• ON/OFF safety power switch (no key required, no key to get lost!)
• Cordless/rechargeable-includes recharge adapters for standard 110 volt AC wall socket
and vehicle's 12 volt DC accessory outlet using adapter cables
• Powerful-400 instantaneous cranking amps; 1800 peak amps
• Includes non-spillable, maintenance-free, heavy duty, 19 ampere hour sealed lead-acid battery
• Audible Polarity Alarm to warn of reverse polarity
• Requires no maintenance (other than recharging) for optimum operation
• Heavy duty, industrial grade copper clamps and #4AWG jumper cables-with exclusive
recessed cable holsters
• Built-in 260 PSI Compressor with Lighted Gauge
• Built-in, removable Fluorescent Lantern
• Storage channels that keep jumper cables and the compressor hose out of the way until they
are needed and allow Power City to securely lay against flat surfaces
• 110 volt AC charger is Underwriter Laboratories safety tested and listed
• Easy-to-read LED Battery Charge Status Display - activated by pressing the Charge Status
Button and automatically activated during AC recharge
1.3
USE POWER CITY TO:
• Jumpstart (using heavy duty battery cable and clamps) any vehicle with a standard 12 volt DC
battery system: boat, truck, car, airplane, RV, personal watercraft, snowmobile, tractor, etc
.
• Power/Recharge: AC Laptop computers and printers, color TVs up to 13”, reading lamps,
fans, small appliances and power hand tools, cellular phones, camcorders, power tool
rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC
standard-type plug
• Operate (using 23 ampere rated 12 Volt Accessory Sockets): 12 volt DC Fans, fluorescent
worklights, air compressors, spotlights, TVs, portable radios, cassette or CD players and
more. Can operate and quick-charge a cellular phone by using the phone's 12 volt DC
adapter cord
• Inflate truck, auto, motorcycle and trailer tires and small popular beach and camping
accessories such as volley balls, soccer beach balls, saving valuable time and effort
• Illuminate areas: under the hood, inside tents, work areas while changing tires, etc. Lantern
is removed from Main Unit and powered by Extension cord for light where you need it
NOTE: Other appliances may also be used with the Power City as long as they do not exceed
the 23 ampere limit of the units cigarette lighter type socket or the 200 watt limit of the
inverter.
READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, BEFORE USING THIS
PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS, AND SAFETY PROCEDURES
AND MANUFACTURER'S GUIDELINES FOR YOUR VEHICLE BATTERY.
IMPORTANT: This unit is delivered in a partially charged state - you must fully charge it
before using it for the first time. Initial AC Charge should be for 24 hours.
Refer to Section 7 for use of Recharge Cables, AC Adapter and detailed charging instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
1.4
STORAGE LOCATIONS
Figure 3 shows all removable parts and their locations. Note the location of the storage
channels for the jumper cables and compressor hose and nozzle. Two cables are supplied with
Power City and they are the Inverter Power Cable with attached Lantern Extension cord and the
DC Recharge Cable. They fit inside the Cable Storage Hatch. Three compressor hose adapters
(nozzles) are also stored in the Cable Storage Hatch.
10
1. TIRE VALVE CONNECTOR
11
9
FIGURE 3
2. COMPRESSOR HOSE
3. AC/DC CHARGER
4. INVERTER POWER CORD,
LANTERN EXTENTION
CORD
1
5. CABLE & NOZZLES
STORAGE COMPARTMENT
6. DC RECHARGE POWER
CORD
2
3
8
7. CABLE STORAGE CHANNEL
8. NEGATIVE JUMPER CABLE
9. POSITIVE JUMPER CABLE
10. COMPRESSOR HOSE
STORAGE CHANNEL
11. HANDLE
12
7
12. 3 COMPRESSOR HOSE
ADAPTORS
4
6
5
2.
USING POWER CITY AS A JUMPSTART SYSTEM
Read all Warnings, Cautions and Notes carefully before using these instructions.In particular
read and understand the WARNINGS printed on inside cover.
2.1
JUMPSTART PROCEDURE
1. Turn Off ignition and all accessories (radio, a/c, lights, cell phone, etc.). Place vehicle in
"park" and set the emergency brake.
2. Make sure Power City's Safety Switch is turned Off.
3. Observe jumpstarting negative or positive ground system, as follows: Negative ground
(negative battery Terminal connected to chassis) - most common.
4. Make sure Power City's Main Unit Safety Switch is turned Off.
5. Carefully lift negative (black) jumper cable wire from storage channel starting at clamp end
of cable.
6. Squeeze negative (black) clamp handles and slide clamp from holster.
7. Carefully lift positive (red) jumper cable wire from storage channel starting at clamp end of cable.
8. Squeeze positive (red) clamp handles and slide clamp from holster.
9. Connect positive (+) red clamp to vehicle's positive battery terminal.
10. Connect negative (-) black clamp to chassis or a solid, non-moving, metal vehicle
component or body part - never clamp directly to negative battery terminal or moving part.
If audible alarm sounds, DO NOT turn ON Safety Switch reverse polarity of cable connections.
11.Turn On Power City's Safety Switch
12.Start vehicle (crank engine in 5 - 6 second bursts) If engine won't start, seek help and go to
step 15.
13.After vehicle starts turn Power City's Safety Switch to Off position.
14.Leave engine running.
15.Remove clamps (disconnect the negative (black) clamp first; followed by the positive (red)
clamp and store cables and clamps.
16.Squeeze negative (black) clamp handles and slide clamp into holster.
17.Carefully press negative (black) jumper cable wire into storage channel starting at Lantern
end of cable.
18.Squeeze positive (red) clamp handles and slide clamp into holster.
19.Carefully press positive (red) jumper cable wire into storage channel starting at Lantern end
of cable.
20.Recharge Power City as soon as possible.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
3.
USE AS A 12 VOLT DC PORTABLE POWER SUPPLY
WARNING: NEVER INSERT A CIGARETTE LIGHTER IN POWER CITY’S ACCESSORY SOCKET.
1. Lift up the cover of one of the12 volt DC Accessory Sockets.
2. Insert the 12 VOLT DC plug from the appliance into the Accessory Socket.
3. Switch on the appliance, as usual.
4. Periodically press the Battery Status Pushbutton to check battery status.
5. When the Charge Status goes to one red LED, recharge the Main Unit battery.
CAUTION: DO NOT USE POWER CITY TO OPERATE DC APPLIANCES THAT DRAW MORE
THAN 23 AMPS.
4.
POWER INVERTER
The Power Inverter is an electronic device that converts low voltage DC (direct current) from the
battery or other power source to standard 110 volt 60 Hz AC (alternating current) household
power. Safety features include an audible low battery alarm and automatic shutdown to
prevent damage to your Power City internal battery. See Figure 4.
2
1
FIGURE 4
3
5
1. INVERTER LOCK TABS
2. COVER TAB
3. RED SHUT DOWN LED
4. INVERTER ON/OFF SWITCH
5. 110 VOLT AC SOCKET
4
6. GREEN OPERATING LED
7. LIGHTED COMPRESSOR
GAUGE
7
6
4.1
INVERTER OPERATION
Removing the cover that protects the AC receptacle on the inverter can access the inverter.
NOTE: On this end of the inverter are: the AC receptacle, the On/Off Switch, a green LED and
a red LED. The green LED, when lit, indicates power is applied to the inverter and it is
operating properly. The red LED, when lit, indicates that something caused the inverter to
shut down. The green LED will not be lit under shutdown conditions. Inverter shutdown is
caused by: under- or over-voltage, overheat or overload. If the inverter shuts down, first
check the Main Unit battery (use Battery Status Push-button and Display) to see if the main
battery is discharged, Recharge the battery as soon as possible. If another condition caused
the shutdown, investigate the appliance for excessive wattage or a connection between
neutral and ground (explained later). If the inverter feels very warm let it cool before
restarting it. Restart is accomplished by turning the Inverter Switch Off, then On.
Operation is simple:
• Remove Inverter's Receptacle Cover
• Plug the appliance's 110 volt plug into the Standard AC receptacle on the inverter.
• Turn On the inverter power switch.
• Turn On the appliance and operate it as usual.
• After use, turn off the power inverter's On/Off Switch
The Inverter can also be used away from the Main Unit by removing it from it's mounting on the
Main Unit and powering it from the Inverter Power Cable. Located in the Cable Storage
Compartment. See Figure 3.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
4.2
PRINCIPLES OF OPERATION
The Power Inverter converts power in two stages. The first stage is a DC-to-DC conversion
process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage is
the actual inverter stage that converts the high voltage DC into 110 volts, 60 Hz AC, Modified
Sine Wave (MSW). MSW is a waveform that has characteristics similar to the sine wave shape
of utility power. This type of waveform is suitable for most AC loads, including linear and
switching power supplies used in electronic equipment, transformers, and motors. The modified
sine wave produced by the Power Inverter has an RMS (root mean square) voltage of 110 volts,
which is the same as standard household power. Most AC voltmeters (both digital and analog)
are calibrated for RMS voltage under the assumption that the waveform measured will be a
pure sine wave. These meters will NOT READ the RMS voltage of a modified sine wave
correctly. They will read about 20 to 30 volts low when measuring the output of the power
inverter. For accurate measurement of the output voltage of this unit, use a voltmeter marked
“TRUE RMS”. Figure 5 compares a Modified Sine Wave with a True Sine Wave.
FIGURE 5
The Power Inverter is incorporated into the Power City Main Unit. It's DC source is the main
unit's 12 volt 19AH battery. Power is provided to the inverter through two flat contacts on the
bottom of the inverter. The inverter operates on stored energy in the main battery. With a full
charge on the main battery, the inverter will supply a load of 100 watts for approximately one
hour and 5 minutes. Lower wattage loads will operate longer, higher wattage loads will operate
for a shorter time using energy from the main battery.
When the inverter is operated away from the main unit, the power source must provide
between 11 and 14.5 volts DC and must be able to supply the necessary current (amps) to
operate the load. The power source may be a battery or a well-regulated DC power supply. To
obtain a rough estimate of the current (in amperes) that the power source must deliver, simply
divide the power consumption of the load (in watts AC) by 10.
Example: If a load is rated at 100 watts AC, the power source must be able to deliver:
100 / 10 = 10 amperes
CAUTION: The inverter must be connected only to batteries with a nominal output voltage of
12 volts. The unit will not operate from a 6 volt battery and will sustain permanent damage
if connected to a 24 VOLT battery.
The inverter may be used whether or not the vehicle's engine is running. However, the inverter
may not operate while the engine is starting since the battery voltage can drop substantially
during engine cranking. The Inverter draws less than 0.06 ampere from the battery when it is
not supplying power to a load.
4.3
CONNECTING INVERTER TO POWER SOURCE AWAY FROM MAIN UNIT
The Inverter can be used away from the Main Unit by removing it from it's mounting on the
Main Unit and powering it from the Inverter Power Cable, located in the Storage Compartment
in the back of unit. The Power Inverter has two flat metal contacts that normally mate with the
connector on the main unit. These flat contacts are connected to the Inverter Power Cable (black
and red color) when the inverter is removed from the unit and operated away from the unit. The
Inverter Power Cable comes equipped with a cigarette lighter type plug is then plugged into
any 12 Volt DC source that can supply the current to operate the load on the inverter. The tip of
the plug is positive and the side contact is negative. Connect the Power Inverter to the power
source by inserting the DC plug firmly into the cigarette lighter (accessory) socket of a vehicle or
other DC power source. The connection to the cigarette lighter socket can be improved by
slightly rotating the plug in the socket. See Figures 6 and 7.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
FIGURE 6
FIGURE 7
LIFT INVERTER
TO REMOVE
COMPRESSOR
GAUGE
TO 12 VOLT
DC SOURCE
INVERTER/LANTERN
POWER CABLE
FLAT PINS
4.3.1 PROCEDURE FOR CONNECTING INVERTER TO REMOTE DC SOURCE
Open the Cable Hatch and remove the Inverter Power Cable (the one with the Lantern Extension
Cord) Press the Inverter Cover Tab and remove the Cover. Ensure that the Inverter’s Power
Switch is OFF. Then press the two tabs that lock in the Inverter and release the Inverter and slide
it out of the mounting. See Figure 4.
NOTE: The two flat pins on the bottom of the Inverter. One pin is wider than the other pin.
Connect the DC Recharge Cable onto these flat pins. Connect the Plug of the DC Recharge
Cable to a 12 volt DC source.
CAUTION:
When operating inverter from cigarette lighter plug, do not exceed 150 watts for long
periods of time.
4.3.2 OPERATING TIME
Assuming a typical vehicle battery is the power source, a minimum operating time of 2 to 3
hours can be expected. In most instances, 5 to 10 hours of operating time is achievable.
However, Vector recommends that the operator start the vehicle every 2 to 3 hours to recharge
the battery system. This will guard against any unexpected shutdowns of the equipment and will
ensure that there is always sufficient battery capacity to start the vehicle's engine. The inverter
will sound it's alarm when DC voltage drops to 10.6 volts.
CAUTION: Reverse polarity connection will result in damage to the inverter. THIS WILL VOID
THE WARRANTY.
If the inverter is connected to the incorrect polarity, the fuse will blow. If the unit does not
function after replacement of the fuse, the unit must be returned to Vector for repair. Repairs for
this type of damage are not covered by warranty.
CAUTION: Do not use with positive ground electrical systems (the majority of modern
Automobiles, RVs and Trucks are negative ground).
4.4
POWERING AN AC LOAD
The Power Inverter is equipped with a standard AC household-type receptacle and On/Off
Switch. Plug the power cord from the equipment you wish to operate into the AC receptacle.
The green LED will light to indicate that the unit is functioning. Make sure the wattage rating of
your equipment is within 200 watts. If so, turn on your equipment. If an audible alarm sounds,
the DC supply voltage is too low. If the inverter is connected to the Main Unit, then the battery
needs to be recharged. If the inverter is connected to another DC source, then the voltage is too
low because of a discharged battery or the wiring gauge is not heavy enough.
WARNING ABOUT OUTLET STRIP USE: Remove appliance plug from outlet strip or turn off
inverter before working on the ac appliance. multiple outlet power strips with switches & circuit
breakers only interrupt power to the "hot" receptacle terminals. the "neutral" terminals remain
powered with respect to the "ground" terminals.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
DO NOT CONNECT TO AC DISTRIBUTION WIRING: the inverter is engineered to be
connected directly to standard electrical and electronic equipment in the manner described
above. Do not direct wire the power inverter to household or RV ac distribution wiring. Do not
connect the power inverter to any AC load circuit in which the neutral conductor is connected to
ground (earth) or to the negative of the DC (battery) source.
CAUTION: Rechargeable appliances
Certain rechargeable devices are recharged by plugging them directly into an AC receptacle.
when first using a rechargeable device, monitor its temperature for the initial ten minutes of use
to determine whether it becomes warmer than usual. If excessive heat is generated, it is a good
indication that the device should not be used with this inverter. This problem does not occur with
the majority of battery-operated equipment. Most of these devices use a separate charger or
transformer that is plugged into an AC receptacle. This inverter is easily capable of powering
most chargers and transformers.
4.5
PLACEMENT OF THE POWER INVERTER
For best operating results when used away from the Main Unit, the inverter should be placed on
a flat surface, such as a vehicle seat or floor. Keep in mind that the Inverter will generate heat –
the larger the AC load the more heat generated. Position the Inverter so that casual brush
against a hot inverter surface will not distract a driver.
WARNING: Inverters generate heat while operating. Power inverters should only be used in
locations that meet the following criteria:
DRY – Do not allow water or other liquids to come into contact with the inverter.
COOL – Ambient air temperature should be between 30 degrees f (-1 degree c)
non-condensing, and 105 degrees f (40 degrees c). do not place the inverter on or near a
heating vent or any piece of equipment that is generating heat above room temperature. Keep
the inverter away that from direct sunlight, if at all possible.
VENTILATED – Keep the area surrounding the inverter clear to ensure free air circulation
around the unit. Do not place items on or over the inverter during operation. the unit will shut
down if the internal temperature gets too hot. restart the unit after it cools.
SAFE – Do not use the inverter near flammable materials or in any locations that may
accumulate flammable fumes or gases.
4.6
OPERATING TIPS
Rated versus Actual Current Draw of most equipment–electrical tools, appliances and
audio/video equipment have labels that indicate the power consumption in amps or watts. Be
sure that the power consumption of the item you wish to operate is rated at 200 watts or less.
(If the power consumption is rated in amps AC, simply multiply by the AC volts (110) to
determine the wattage). The inverter has overload protection, so it is safe to try to operate
equipment rated at 200 watts or less. The inverter will shut down if it is overloaded and will
restart once the overload is removed.
Resistive loads are the easiest for the inverter to run; however, larger resistive loads, such as
electric stoves or heaters, require more wattage than the inverter can deliver. Inductive loads,
such as TV's and stereos, require more start-up current to operate than do resistive loads of the
same wattage rating. Induction motors, as well as some televisions, may require 2 to 6 times
their wattage rating to start up. The most demanding in this category are those that start under
load, such as compressors and pumps. Testing is the only definitive way to determine whether a
specific load can be started and how long it can run. The unit will simply shut down if it is
overloaded. To restart the unit after a shutdown due to overloading, momentarily turn off the
power to the unit.
THE INVERTER WILL NOT OPERATE HIGH WATTAGE APPLIANCES OR EQUIPMENT THAT
PRODUCE HEAT, SUCH AS HAIR DRYERS, MICROWAVE OVENS AND TOASTERS.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
4.7
INVERTER FUSE REPLACEMENT
The following assumes that the Main Unit battery has a charge and that there is no output from
the 110 VAC receptacle. If you find that a fuse is blown (open) determine the cause of the short
before restarting the power inverter again. Fuse Replacement in Automobile: Most automobile
cigarette lighter circuits use fuses at 15 Amps or greater. The inverter can deliver 180 watts with
a 20 Amp lighter socket fuse. The inverter must be removed from the Main Unit to gain access
to the fuse. The fuse, spade lug type 30 amperes) is located under the black protective cap on
the connector end of the inverter.
1. Lift off the protective cap from the inverter and set it aside.
2. Press the release buttons that hold the inverter in place and slide the inverter out of the
mounting.
3. Lift the end of the black protective fuse cover closest to the power pins and rotate upwards to
expose top of fuse.
4. Grasp the fuse in the center and pull away from the inverter.
5. Check the fuse visually or with a continuity checker.
6. If fuse is open (blown) replace with another with same type and rating.
7. Close fuse cover and slide inverter back into its mounting and place the On/Off Switch in the
On position.
8. If fuse is good the green LED will light.
9. Check for proper operation by powering a 110 VAC appliance. If there is still a problem,
call Vector Technical Support at 954-584-4446.
NOTE: If the Main Unit battery is discharged, the Inverter may also be quickly checked by
connecting the Inverter Power Cable to the inverter's power pins and plugging the DC Plug
into a known to be operating 12 volt DC accessory socket.
5.
COMPRESSOR/TIRE INFLATOR
This built-in 12 Volt DC compressor is the ultimate compressor for all Vehicles, Trailer Tires and
recreational inflatables. Three different sized nozzles are supplied. Each nozzle will clip on the
end of the standard tire Valve connector located at the free end of the compressor hose. The
Compressor nozzles are stored inside the Cable Hatch. The compressor hose with tire fitting is
stored in a retaining channel between the jumper cable channels on the rear of the unit. The
Compressor’s ON/OFF Switch is located on the side of the Main Unit near the AC Recharge
Port. The compressor can operate long enough to fill up to 3 average sized tires before the
Power City internal battery must be recharged. When the Compressor is turned on, the gauge
will light up.
5.1
COMPRESSOR USE
IMPORTANT: Read Instructions Carefully To Avoid Possible Injury Or Property Damage.
The Compressor may be used by removing the air hose from it’s storage channel and fitting an
appropriate nozzle to the air hose. An On/Off switch located on the Main Unit controls the
power to the Compressor. Refer to Figures 2 and 3 for locations of Compressor Switch and
Nozzle Storage Hatch.
For Nighttime use: Remove the Lantern from the Main Unit and power it from the Extension
cord. This way you can position the Lantern to see the Pressure Gauge and the item being
inflated. Refer to Section 6, below.
5.2
WARNINGS
The compressor is capable of inflating to 260 pounds per square inch (psi) pressure. To avoid
over-inflation, carefully follow instructions on articles to be inflated. Never exceed recom-
mended pressures. Bursting articles can cause serious injury. Always check pressure with the
pressure gauge Never leave compressor unattended while in use. Allow unit to cool after 10
minutes of continuous operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
5.3
TIRE INFLATION OR PRODUCTS WITH A VALVE STEM
1. Place connector (chuck) on valve stem.
2. Push connector toward valve stem and close thumb latch.
3. Make sure connector is pushed on to valve stem as far as possible before closing thumb latch.
4. Check pressure with the pressure gauge. (Refer to paragraph 5.5)
5. When desired pressure is reached, open thumb latch and remove connector from valve stem.
6. Turn OFF Compressor Power Switch
7. Store Compressor Hose and tire fitting in storage channel
IMPORTANT: Always leave the thumb latch in the open position when storing unit.
5.4
INFLATE OTHER ARTICLES (WITHOUT VALVE STEM)
Inflation of other than tires requires use of one of the adapters (nozzles).
1. Position the Main Unit so you have access to the Cable Storage Hatch.
2. Open the hatch and remove the nozzles noting their storage positions.
3. Insert appropriate adaptor (e,g. needle) into connector (chuck) and close thumb latch.
4. Refer to "Typical Inflation Times" for approximate pressure and time. Small items like volley
balls, footballs, etc. inflate very rapidly.
5. Insert adaptor (e.g needle) into item to -be inflated and inflate to desired pressure.
6. Turn ON compressor switch – inflate to desired pressure or fullness (refer to paragraph 5.5)
7. Remove adaptor.
5.5
TYPICAL INFLATION TIMES
The following are approximate pressure and inflation times for various items.
Warning: Always follow tire manufacturers recommendations for pressure on item to
be inflated.
VEHICLE AND TRAILER TIRES
TIRE SIZE ................................... PRESSURE .............. TIME FROM “0” PRESSURE
155/80R 13” ...............................26 PSI ............................. 2.50 MIN.
185/70R 14” ...............................30 PSI ............................. 4.50 MIN.
235/75R 15” ...............................30 PSI ............................. 6.50 MIN.
235/85R 16” ...............................50 PSI ............................ 16.00 MIN.
BICYCLE TIRES
TIRE SIZE ................................... PRESSURE .............. TIME FROM “0" PRESSURE
27 X 1” RACING .......................... 10 PSI ............................... 40 SEC.
INFLATABLE ARTICLES
ITEM .......................................... PRESSURE ............. TIME FROM "0" PRESSURE
FOOTBALL ....................................13 PSI ...........................24 SECONDS
BASKETBALL ..................................9 PSI ............................ 20 SECONDS
VOLLEYBALL ..................................5 PSI ............................. 6 SECONDS
6.
LANTERN
6.1
LANTERN OPERATION ON MAIN UNIT
The main power On/Off Safety Switch must be in the On position to turn on lantern while
mounted on main unit. The Lantern is controlled by an On/Off pushbutton switch located on the
lens side of the Lantern. It is powered from the main unit’s battery when it is mounted on the
Main Unit. Starting with a full charge, the Main Unit’s battery can power the Lantern for
up tp approximately 22 hours.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
6.2
LANTERN OPERATION DETATCHED FROM MAIN UNIT
The Lantern may be removed for use away from the Main Unit by first sliding the top latch back
and then lifting the Lantern
➜
FIGURE 8
LANTERN
LATCH
A barrel connector near the spring contacts on the back of the Lantern accepts either the AC
Recharge or DC Inverter Power Cable’s Lantern Extension cord. If there is a current applied
through the barrel receptacle, and the Lantern’ On/OFF Switch is ON, the Lantern will light.
6.2.1 LANTERN OPERATION FROM DC SOURCE
The Lantern can be powered from the Main Unit using the Inverter Power Cable with attached
Lantern Extension Cord. This allows great flexibility in positioning the Lantern during tire infla-
tion and during under-the-hood inspections. See Figure 9. If an alternative 12 Volt DC source is
available, the Lantern can be powered from a standard 12 volt accessory socket. The Lantern
draws 9 watts so operation from an automobile battery is very efficient. With a full charge, a
typical auto battery can power the Lantern from 40 to 60 hours.
LANTERN
FIGURE 9
ON/OFF
SWITCH
DC PLUG CONNECTED
TO ACCESSORY SOCKET
OF MAIN UNIT
INVERTER
POWER CABLE
DC LANTERN/INVERTER
CORD CONNECTOR
LANTERN
EXTENTION CORD
6.2.2 LANTERN OPERATION 110V WITH AC RECHARGE ADAPTER
The AC Recharger can be directly connected to the
Lantern using the barrel receptacle on the Lantern.
The Lantern can be powered using the AC Recharge
Adapter if household AC power is available. Powering
the Lantern from an AC source preserves the charge on
the Main Unit’s internal battery.
110V AC RECHARGE
FIGURE 10
ADAPTER FOR WALL
Download from Www.Somanuals.com. All Manuals Search And Download.
13
6.3
LAMP REPLACEMENT
The only lamp is in the Lantern Assembly. For any maintenance of the lamp, you will need a
small Phillips screwdriver and a soft clean cloth. Replacement bulbs are available from Vector
Technical Support Department; call (954) 584-4446 for replacements. Warning Fluorescent
bulbs are fragile, be careful while handling.
NOTE: DO NOT use any metal tools to remove or replace bulb. See Figure 10.
FIGURE 11
FLUORESCENT
LAMP
SPRING CLIP
LANTERN
LENS
LENS
RETAINING
SCREW
BOTTOM
LENS TAB
1. Make sure the Lantern is turned off.
2. Remove the Lantern Assembly from the main unit.
3. Remove the Phillips type screw (turn counter-clockwise).
4. Lift the lens upward and off and set it aside.
5. Using a clean cloth, rotate the top of the bulb away from the reflector.
6. Pull the burned out bulb upwards and towards the front of the Lantern Assembly.
This will remove it.
7. Replace with a new fluorescent 9 watt bulb.
8. Snap the lens into place (bottom tab first) and replace the two screws.
9. Carefully turn the screw clockwise to tighten. DO NOT OVER TIGHTEN screw.
10.Dispose of burned out bulb in a responsible manner. Follow local ordinances for disposal.
7.
RECHARGING POWER CITY’S BATTERY
Lead-acid batteries require maintenance to maintain a full charge and to ensure good battery
life. All lead-acid batteries suffer from self-discharge over time and more rapidly when they are
at higher temperatures. Therefore, these types of batteries need periodic charging to replace
energy lost through self-discharge. When Power City is not in use Vector recommends that the
batteries be recharged at least every 60 days.
All batteries must be recharged as soon as possible after each use. If a battery is allowed to
remain in a discharged state, battery life will be reduced.
NOTE: Recharging battery after each use will prolong battery life; frequent heavy discharges
between recharges will reduce battery life. Overcharging will reduce battery life.
The battery can be recharged using several different methods. The time required to fully
recharge these batteries depends on the charge status of the battery after the use of DC
appliances, Inverter and Compressor.
NOTE: Pressing the battery status push-button turns on the battery status display on the
main unit
Check the battery charge level by pressing the Charge Status Button. The LED Charge Status
display will indicate the level of charge of the battery.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
7.1
AC RECHARGE
AC Recharge requires the use of the supplied AC/DC Adapter. The adapter must be powered
from 110 volt AC, 60 Hz North American standard household AC receptacles.
The Battery Status Display will automatically activate during AC recharge. As recharge
progresses, the red LEDs will light one by one. Charge the Power City until the Battery Status
Display lights the green FULL LED. Continue to recharge for one to two hours, and then discon-
nect the AC Recharger. AC recharge is an automatic float and taper charge and The AC
Recharger can be left connected to the Main Unit for long periods. See Figure 2 for AC Re-
charge connection to the Main Unit. Refer to Section 7.2 for Recharge Method.
Make sure that the inverter, compressor and lamp ON/OFF Switches are in off position during
AC recharging.
7.2
DC RECHARGE
Power City is supplied with two accessory cables. One cable is a black Inverter Power Cable
with an attached thinner Lantern Extension Cord. It is to power the inverter when it is used with
another accessory socket in a vehicle or boat. An attached thinner wire is dubbed Lantern
Extension Cord" and it is used to power the Lantern. The DC Recharge Cable has red and black
wire and it mates with the Inverter Power Cable to make a DC to DC cable.
After recharge, the accessory cables are stored in their own Cable Storage Hatch in the Main Unit.
Recharging the Main Unit’s internal battery from an external DC power source requires the use
of the DC Recharge Cable and the Inverter Power Cable. See Figure 11. The Lantern Extension
Cord can be connected to the Lantern to simultaneously recharge the Main Unit and power the
Lantern (not shown).
INVERTER
POWER CABLE
FIGURE 12
CONNECTOR
PAIR
LANTERN
EXTENSION
CORD
DC PLUG
BARREL
DC RECHARGE
PLUG
CONNECTOR
Make sure Safety ON/OFF Switch, inverter, and compressor switches are in the OFF position
during DC recharging.
Unlike the AC Recharge method, DC Recharge does not automatically activate the Battery
Status Display. To check the battery status, press the Battery Status Display Push-button. If the
Jump Starter's battery is fully discharged, it is recommended that the host vehicle or boat's
engine being used for recharging be left operating while the unit is being charged using the 12
volt DC/DC method.
WARNING: DO NOT recharge main unit for more than 8 hours maximum using 12 volt DC
method. do not charge lantern for more than five hours using the dc recharge method.
1. Remove both power cables from the Cable Storage Hatch.
2. Insert the red DC Recharge Cable's rectangular connector flat pins into the black rectangular
connector on the Inverter Power Cable.
3. Insert black DC Plug on the Inverter Power Cable into a DC Accessory socket on the
Main Unit.
4. Plug the red DC Plug into an accessory socket in a vehicle, power supply or other 12 VOLT
DC source.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
5. Charge the unit until the green CHARGED indicator is lit when the Charge Status Button is
pressed - DO NOT EXCEED 8 HOURS MAXIMUM.
6. After charging, disconnect the cables and store them in the Cable Storage Hatch.
7.3
ALTERNATE DC RECHARGE
If the Inverter is removed from the Main Unit, the DC Recharge Cable can be directly connected
to the black power connector that mates with the Inverter's flat power pins. In this way, the
Inverter and Inverter Power Cable can be used away from the Main Unit and DC Recharge can
be accomplished. Follow the same charging time and monitor the battery charging by using the
Battery Status Push-button and Display.
7.4
SIMULTANEOUS DC RECHARGE AND INVERTER OPERATION
Connecting the Inverter Power Cable and the DC Recharge Cable makes a heavy-duty DC-to-
DC Cable that can simultaneously recharge the Main Unit and operate the Inverter while it is
mounted on Power City. Plug One DC Plug into Power City Accessory Socket and the other DC
Plug into a vehicle accessory socket. When using with AC appliances that draw over 120 watts
and at the same time the Power City’s Battery is deeply discharged, this could draw more than
the vehicle's accessory socket's fuse can handle and result in a blown fuse. Use this method with
caution. Periodically monitor DC recharge using the Battery Status Pushbutton and Indicators.
8.
MAINTENANCE/REPLACEMENT PARTS
For replacement parts (bulbs, batteries, charging adapters, cables, etc.), contact Vector
Technical Support: (954) 584-4446 or call toll-free (866) 584-5504. Except for a fuse in the
inverter and a lamp in the Lantern, there are no user serviceable parts inside Power City.
Periodically, the cables and connectors should be inspected for damage, corrosion and dust
and dirt. If surfaces are dirty, they can be wiped clean with a cloth moistened with water and a
small drop of detergent. Contacts can be wiped clean with a dry cloth.
WARNINGS: Other than a fuse in the inverter and a lamp in the lantern, there are no user
serviceable parts inside. DO NOT operate unit if there is any evidence of damage. The
product must be returned to vector for testing and repair. Replace any damaged cables
immediately before further use.
Refer to section 4.6 for inverter fuse replacement. Refer to section 6.4 for lamp replacement.
9.
BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed
of properly. Recycling is required. Contact your local authority for information. Failure to
comply with local, state and federal regulations can result in fines, or imprisonment. Sealed
lead battery, must be recycled or disposed of properly. For more information on recycling this
battery, call toll-free 877/288-7722.
BATTERY DISPOSAL WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to
prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
PRBA
PRBA
ALWAYS RECYCLE
Download from Www.Somanuals.com. All Manuals Search And Download.
16
10.
SPECIFICATIONS:
Jump Start Clamps ..................................................... 400 Amps - Heavy Duty Copper
Jumper Cables ....................................................................... #5AWG Welding Cable
Peak Amps......................................................................................................... 1800
Instant Amps ........................................................................................................ 400
Main Battery ................................................. 12 Volt, 19 Amp Hour, Sealed Lead-Acid
Lantern Lamp .....................................................................11 Watt Flourescent U Tube
Dual Accessory Socket Protection ................................... 23 Amp Self-Resetting Breaker
Power Inverter Continuous .......................................... 200 Watt, 60 Hz, 110-120 VAC
Power Inverter Peak .................................................... 300 Watt, 60 Hz, 110-120 VAC
Inverter Waveform........................................................................ Modified Sine Wave
Inverter DC Input Range................................................................... 10.0 to 14.6 VDC
Inverter Audible Alarm ................................................................................ 10.6 VDC
Automatic Shutdown ....................................Low Voltage, Overload, Over Temperature
Compressor .............................................................................. Max Pressure, 300 PSI
Pressure Gauge Type ..................................................................... Lighted Analog Dial
Air Delivery ...................................................................................................7kg /cm
Three .............................................................................................................. nozzles
Operating temp...................................................................... -20 deg C to +80 deg C
Motor current .................................................................................................. 9 Amps
Dimensions .............................................................. 17 in. W X 5.5 in. D X 10.5 in. H
Weight .............................................................................................................18 Lbs
Download from Www.Somanuals.com. All Manuals Search And Download.
17
11.
WARRANTIES
120 DAY LIMITED WARRANTY REGISTRATION FORM
All Vector Manufacturing, Ltd. products are warranted to the original purchaser only for 120
days from the date of purchase, to be free of defects in materials and workmanship. Vector
Manufacturing, Ltd. disclaims any liability for consequential damages. In no event will Vec-
tor Manufacturing, Ltd. be responsible for any amount of damages beyond the amount paid
for the product at retail. In the event of a defective item, please ship the item prepaid, with a
complete explanation of the problem, your name, address and daytime telephone number.
Vector Manufacturing, Ltd. will, at its option, replace the defective part.
The following situations are not covered under this warranty:
➜ Cost of shipment to Vector Manufacturing, Ltd.
➜ Normal wear and tear, including chips, scratches, abrasions, repairs by unauthorized
persons or failure to follow recommended care and use instructions.
➜ Damage caused by misuse, abuse, neglect, alterations, repairs by unauthorized
persons, or failure to follow recommended care and use instructions.
➜ Bulbs and batteries.
➜ Please activate my Limited Warranty for Model #VEC029AC. Enclose copy of original sales receipt.
Name _____________________Street Address __________ City _______________
State _____________________ Zip Code ________________________________
Phone ____________________Fax _________________ E-mail______________
Store where purchased _________________________________________________
UPC Number from package (12 digits) ________________________________________
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this
warranty. Mail the completed registration form, along with a copy of the original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
Download from Www.Somanuals.com. All Manuals Search And Download.
18
3 YEAR EXTENDED WARRANTY REGISTRATION FORM
Certain Vector Manufacturing, Ltd. products are warranted to the original purchaser
only, for three (3) years from the date of purchase, to be free of defects in materials or
workmanship. Vector Manufacturing, Ltd. disclaims any liability for consequential dam-
ages. In no event will Vector Manufacturing, Ltd. be responsible for any amount of
damages beyond the amount paid for the product at retail. In the event of a defective
item, please ship the item to us, prepaid, with an explanation of the problem, your
name, address and daytime telephone number. Vector Manufacturing, Ltd. will, at its
option, replace or repair the defective part.
The following situations are not covered under this warranty:
➜ Cost of shipment to Vector Manufacturing, Ltd.
➜ Normal wear and tear, including chips, scratches, abrasions, repairs by unauthorized
persons or failure to follow recommended care and use instructions.
➜ Damage caused by misuse, abuse, neglect, alterations, repairs by unauthorized
persons, or failure to follow recommended care and use instructions.
➜ Bulbs and batteries.
➜ Please activate my Extended Warranty for Model #029AC. Enclose copy of original sales receipt.
Name _____________________ Street Address ___________________
City ______________________ State _________ Zip Code __________
Phone_____________________ Fax __________________________
E-mail __________________________________________________
Date of purchase ____________________________________________
Store where purchased ________________________________________
UPC Number from package (12 digits) _______________________________
Form of Payment (US$45.00) [ ] Check [ ] Money Order
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to
activate this warranty. Mail the completed registration form, along with a copy of the original sales
receipt, and a check or money order for US$45.00 made payable to Vector Manufacturing, Ltd., to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
Download from Www.Somanuals.com. All Manuals Search And Download.
19
© 2000 VECTOR MANUFACTURING, Ltd.
FT. LAUDERDALE, FL 33312 MADE IN CHINA
Download from Www.Somanuals.com. All Manuals Search And Download.
|