Vanguard Heating Water Heater UNVENTED VENT FREE NATURAL GAS LOG HEATER User Manual

®
UNVENTED (VENT-FREE)  
NATURAL GAS LOG HEATER  
VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED  
AS A VENTED DECORATIVE APPLIANCE  
OWNER’S OPERATION AND INSTALLATION MANUAL  
FLAME-MAX®  
Golden Oak Log  
Design  
®
18", 24", 30", and 36"  
Remote Ready Model  
Patent Pending  
REMOTE  
OFF  
WARNING: Improper installation, ad-  
WARNING: If the information in this  
justment, alteration, service, or main-  
manual is not followed exactly, a fire or  
tenance can cause injury or property  
explosion may result causing property  
damage. Refer to this manual for cor-  
damage, personal injury, or loss of life.  
rect installation and operational pro-  
— Do not store or use gasoline or other  
flammablevaporsandliquidsinthevicinity  
of this or any other appliance.  
cedures. For assistance or additional  
informationconsultaqualifiedinstaller,  
service agency, or the gas supplier.  
— WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do  
not use any phone in your building.  
• Immediatelycallyourgassupplierfrom  
a neighbor’s phone. Follow the gas  
supplier’s instructions.  
WARNING: This appliance is for in-  
stallation only in a solid-fuel burning  
masonry,UL127factory-builtfireplace,  
or in an approved ventless firebox. It  
is design certified for these installa-  
tionsinaccordancewithANSZ21.11.2.  
Exceptions: Do not install this appli-  
ance in a factory-built fireplace that  
includes instructions stating it has  
not been tested or should not be used  
with unvented gas logs.  
• If you cannot reach your gas supplier,  
call the fire department.  
— Installation and service must be per-  
formed by a qualified installer, service  
agency, or the gas supplier.  
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in  
which it is installed. Provisions for adequate combustion and ventilation air must be  
provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.  
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by  
state or local codes.  
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer  
Save this manual for future reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
PRODUCT  
PRODUCT  
IDENTIFICATION  
FEATURES  
Flame-Max®  
OPERATION  
Golden Oak Logs  
This heater is clean burning. It requires no  
outside venting. There is no heat loss out a  
vent or up a chimney. Heat is generated by  
realistic,dancingyellowflames.Thisheater  
is designed for vent-free operation with flue  
damper closed. It has been tested and ap-  
proved to ANS Z21.11.2 standard for  
unvented heaters. State and local codes in  
some areas prohibit the use of vent-free  
heaters. This heater may also be operated as  
a vented decorative product (ANS Z21.60)  
by opening flue damper (non-thermostat  
operation only).  
One Piece  
Log Set  
Optional  
Remote  
Control  
HI  
MAN  
TEMP  
LO  
AUT  
O
ON  
OFF  
ST  
A
TUS  
Piezo  
Ignitor  
SAFETY PILOT  
This heater has a pilot with an Oxygen  
Depletion Sensor Shutoff System (ODS).  
TheODS/pilotisarequiredfeatureforvent-  
free room heaters. The ODS/pilot shuts off  
the heater if there is not enough fresh air.  
Optional  
Selector  
Switch  
Flame  
Adjustment  
Knob  
Base Assembly  
Control Knob  
PIEZO IGNITION SYSTEM  
This heater has a piezo ignitor. This system  
requires no matches, batteries, or other  
sources to light heater.  
Figure 1 - Product Identification  
UNPACKING  
LOCAL CODES  
REMOTE CONTROL  
ACCESSORIES  
Install and use heater with care. Follow all  
localcodes.Intheabsenceoflocalcodes,use  
the latest edition of The National Fuel Gas  
Code ANS Z223.1, also known as NFPA 54*.  
CAUTION: Do not remove the  
metal Data Plates from the grate  
assembly.TheDataPlatescontain  
important product information.  
There are four optional remote controls that  
can be purchased separately for this log  
heater:  
*Available from:  
American National Standards Institute, Inc.  
1430 Broadway  
1. Remove logs and heater base assem-  
bly from carton. Note: Do not pick up  
heater base assembly by the burner.  
This could damage heater. Always  
handle base assembly by grate.  
• wall switch  
• wall thermostat  
New York, NY 10018  
• hand held ON/OFF remote  
• hand held thermostat remote  
National Fire Protection Association, Inc.  
Batterymarch Park  
2. Remove all protective packaging ap-  
plied to logs and heater for shipment.  
3. Check all items for any shipping dam-  
age. If damaged, promptly inform  
dealer where you bought heater.  
Quincy, MA 02269  
See Accessories, page 25.  
Note: Where listed vented decorative logs  
are required, thermostat operation is not  
permitted.  
The wall thermostat or hand-held thermo-  
stat may not be used where vented decora-  
tive listing is required.  
105273  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
Confined and Unconfined Space  
PROVIDING ADEQUATE  
VENTILATION  
AIR FOR  
The National Fuel Gas Code (ANS Z223.1,  
1992 Section 5.3) defines a confined space  
as a space whose volume is less than 50  
cubic feet per 1,000 Btu per hour (4.8 m3 per  
kw) of the aggregate input rating of all  
appliances installed in that space and an  
unconfined space as a space whose volume  
is not less than 50 cubic feet per 1,000 Btu  
per hour (4.8 m3 per kw) of the aggregate  
inputratingofallappliancesinstalledinthat  
space. Rooms communicating directly with  
the space in which the appliances are in-  
stalled*, through openings not furnished  
with doors, are considered a part of the  
unconfined space.  
COMBUSTION AND  
VENTILATION  
The following are excerpts from National  
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-  
tion5.3, AirforCombustionandVentilation.  
WARNING: This heater shall  
notbeinstalledinaconfinedspace  
or unusually tight construction  
unless provisions are provided  
foradequatecombustionandven-  
tilation air. Read the following in-  
structions to insure proper fresh  
air for this and other fuel-burning  
appliances in your home.  
All spaces in homes fall into one of the three  
following ventilation classifications:  
1. Unusually Tight Construction  
2. Unconfined Space  
3. Confined Space  
The information on pages 4 through 6 will  
help you classify your space and provide  
adequate ventilation.  
Today’s homes are built more energy effi-  
cient than ever. New materials, increased  
insulation, and new construction methods  
help reduce heat loss in homes. Home own-  
ers weather strip and caulk around windows  
and doors to keep the cold air out and the  
warm air in. During heating months, home  
ownerswanttheirhomesasairtightaspossible.  
Unusually Tight Construction  
This heater shall not be installed in a con-  
fined space or unusually tight construction  
unless provisions are provided for adequate  
combustion and ventilation air.  
The air that leaks around doors and win-  
dows may provide enough fresh air for  
combustion and ventilation. However, in  
buildings of unusually tight construction,  
you must provide additional fresh air.  
* Adjoining rooms are communicating only  
iftherearedoorlesspassagewaysorventila-  
tion grills between them.  
Unusually tight construction is de-  
fined as construction where:  
While it is good to make your home energy  
efficient, your home needs to breathe. Fresh  
air must enter your home. All fuel-burning  
appliances need fresh air for proper com-  
bustion and ventilation.  
a. walls and ceilings exposed to the  
outside atmosphere have a con-  
tinuous water vapor retarder with  
a rating of one perm (6x10-11 kg  
per pa-sec-m2) or less with open-  
ings gasketed or sealed and  
Exhaustfans, fireplaces, clothesdryers, and  
fuel burning appliances draw air from the  
house to operate. You must provide ad- b. weather stripping has been  
equate fresh air for these appliances. This  
will insure proper venting of vented fuel-  
burning appliances.  
added on openable windows  
and doors and  
c. caulking or sealants are applied  
to areas such as joints around  
window and door frames, be-  
tween sole plates and floors, be-  
tween wall-ceiling joints, be-  
tween wall panels, at penetra-  
tions for plumbing, electrical, and  
gas lines, and at other openings.  
If your home meets all of the three  
criteria above, you must provide ad-  
ditional fresh air. See Ventilation Air  
From Outdoors, page 6.  
If your home does not meet all of the  
three criteria above, proceed to Deter-  
miningFresh-AirFlowForHeaterLo-  
cation, page 5.  
105273  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
AIR FOR  
COMBUSTION AND  
VENTILATION  
Continued  
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION  
Determining if You Have a Confined or Unconfined Space  
Use this work sheet to determine if you have a confined or unconfined space.  
Space: Includestheroominwhichyouwillinstallheaterplusanyadjoiningroomswithdoorlesspassagewaysorventilationgrillsbetween  
the rooms.  
1. Determine the volume of the space (length x width x height).  
Length x Width x Height = _____________ cu. ft. (volume of space)  
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)  
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of  
the space.  
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.  
_______________ (volume of space) ÷ 50 cu. ft. = (maximum Btu/Hr the space can support)  
Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)  
3. Add the Btu/Hr of all fuel burning appliances in the space.  
Vent-free heater  
Gas water heater*  
Gas furnace  
Vented gas heater  
Gas fireplace logs  
______________ Btu/Hr  
______________ Btu/Hr  
______________ Btu/Hr  
______________ Btu/Hr  
______________ Btu/Hr  
Example:  
Gas water heater  
Vent-free heater  
Total  
40,000 Btu/Hr  
39,000 Btu/Hr  
79,000 Btu/Hr  
+
=
Other gas appliances* + ______________ Btu/Hr  
Total ______________ Btu/Hr  
=
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.  
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.  
____________Btu/Hr (maximum the space can support)  
____________Btu/Hr (actual amount of Btu/Hr used)  
Example: 51,200 Btu/Hr (maximum the space can support)  
79,000 Btu/Hr (actual amount of Btu/Hr used)  
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.  
You must provide additional fresh air. Your options are as follows:  
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-  
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.  
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.  
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.  
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no  
additional fresh air ventilation.  
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space  
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of  
the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.  
Continued  
105273  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
AIR FOR  
COMBUSTION AND  
12"  
VENTILATION  
Continued  
Ventilation  
VENTILATION AIR  
Ventilation Grills  
Into Adjoining Room,  
Option 2  
Grills  
Into Adjoining  
Room,  
Ventilation Air From Inside  
Building  
Or  
Remove  
Door into  
Adjoining  
Room,  
Option  
3
Option 1  
Thisfreshairwouldcomefromanadjoining  
unconfined space. When ventilating to an  
adjoining unconfined space, you must pro-  
vide two permanent openings: one within  
12" of the ceiling and one within 12" of the  
floor on the wall connecting the two spaces  
(see options 1 and 2, Figure 2). You can also  
remove door into adjoining room (see op-  
tion 3, Figure 2). Follow the National Fuel  
Gas Code NFPA 54/ANS Z223.1, Section  
5.3, Air for Combustion and Ventilation for  
required size of ventilation grills or ducts.  
12"  
Figure 2 - Ventilation Air from Inside Building  
WARNING: Rework work-  
sheet, adding the space of the  
adjoining unconfined space. The  
combined spaces must have  
enough fresh air to supply all  
appliances in both spaces.  
Ventilated  
Attic  
Outlet  
Air  
Ventilation Air From Outdoors  
Outlet  
Air  
Provide extra fresh air by using ventilation  
grills or ducts. You must provide two per-  
manent openings: one within 12" of the  
ceiling and one within 12" of the floor.  
Connect these items directly to the outdoors  
orspacesopentotheoutdoors.Thesespaces  
include attics and crawl spaces.  
To Attic  
To  
Crawl  
Space  
IMPORTANT: Do not provide openings for  
inlet or outlet air into attic if attic has a  
thermostat-controlledpowervent.Heatedair  
enteringtheatticwillactivatethepowervent.  
Inlet  
Air  
Ventilated  
Crawl Space  
Inlet Air  
Figure 3 - Ventilation Air from Outdoors  
105273  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
INSTALLATION AND  
CLEARANCES (Vent-Free  
Operation Only)  
INSTALLATION  
WARNING: Never install the  
heater  
NOTICE: This heater is intended  
foruseassupplementalheat.Use  
this heater along with your pri-  
mary heating system. Do not in-  
stall this heater as your primary  
heat source. If you have a central  
heating system, you may run  
system’scirculatingblowerwhile  
using log heater. This will help  
circulate the heat throughout the  
house. In the event of a power  
outage, you can use this heater  
as your primary heat source.  
• in a bedroom or bathroom un-  
less installed as a vented ap-  
pliance (see page 10)  
• in a recreational vehicle  
• where curtains, furniture,  
clothing, or other flammable  
objectsarelessthan42inches  
from the front, top, or sides of  
the heater  
WARNING:Maintainthemini-  
mum clearances. If you can, pro-  
vide greater clearances from  
floor, ceiling, and adjoining wall.  
MINIMUM FIREPLACE  
CLEARANCE TO  
COMBUSTIBLE MATERIALS  
• in high traffic areas  
• in windy or drafty areas  
Log Size  
Side Wall  
Ceiling  
CAUTION: This heater cre-  
ates warm air currents. These  
currents move heat to wall sur-  
faces next to heater. Installing  
heater next to vinyl or cloth wall  
coverings or operating heater  
where impurities (such as to-  
bacco smoke, aromatic candles,  
cleaning fluids, oil or kerosene  
lamps, etc.) in the air exist, may  
discolor walls.  
18", 24",  
16"  
42"  
30", and 36"  
NOTICE: A qualified service per-  
son must install heater. Follow  
all local codes.  
LOG SIZING REQUIREMENTS  
Log  
Minimum Firebox Size  
Size Height Depth Front Rear*  
Width Width  
NOTICE:Stateorlocalcodesmay  
onlyallowoperationofthisappli-  
ance in a vented configuration.  
Check your state or local codes.  
18"  
24"  
30"  
36"  
17"  
17"  
17"  
17"  
14"  
14"  
14"  
14"  
24"  
28"  
34"  
40"  
20"  
21"  
24"  
30"  
WARNING: Before installing  
in a solid fuel burning fireplace,  
thechimneyflueandfireboxmust  
be cleaned of soot, creosote,  
ashes and loose paint by a quali-  
fied chimney cleaner. Creosote  
will ignite if highly heated. A dirty  
chimney flue may create and dis-  
tribute soot within the house. In-  
spectchimneyfluefordamage. If  
damaged,operateheaterwithflue  
damper closed.  
IMPORTANT:Vent-freeheatersaddmois-  
ture to the air. Although this is beneficial,  
installing heater in rooms without enough  
ventilation air may cause mildew to form  
from too much moisture. See Air for Com-  
bustion and Ventilation, pages 4 through 6.  
*Measured at 14" depth  
Carefullyfollowtheinstructionsbelow.This  
will ensure safe installation into a masonry,  
UL127-listedmanufacturedfireplace,orcer-  
tified vent free firebox.  
Minimum Wall and Ceiling  
Clearances (see Figure 4)  
A. Clearances from the side of the fire-  
place opening to any combustible wall  
should not be less than 16 inches.  
CHECK GAS TYPE  
Use only natural gas. If your gas supply is  
not natural gas, do not install heater. Call  
dealer where you bought heater for proper  
type heater.  
B. Clearances from the top of the fireplace  
opening to the ceiling should not be less  
than 42 inches.  
WARNING: Seal any fresh air  
vents or ash clean-out doors lo-  
catedonfloororwalloffireplace.  
If not, drafting may cause pilot  
outage or sooting. Use a heat-  
resistant sealant. Do not seal  
chimney flue damper.  
42"  
16"  
Left and  
Right Sides  
Figure4-MinimumClearancetoWalland  
Ceiling  
Continued  
105273  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
If Using Mantel  
Even if noncombustible material is more  
INSTALLATION  
than 12", you may need the hood accessory  
to deflect heat away from your mantel shelf.  
See Figure 5 and Figures 6 and 7 on page 9  
for minimum clearances.  
You must have noncombustible material(s)  
above the fireplace opening. Noncombus-  
tible materials (such as slate, marble, tile,  
etc.) must be at least 1/2 inch thick. With  
sheet metal, you must have noncombustible IMPORTANT: If you cannot meet these  
material behind it. Noncombustible mate- minimum clearances, you must operate  
rial must extend at least 8 inches up (for all heater with chimney flue damper open. Go  
models). If noncombustible material is less to Installing Damper Clamp Accessory for  
than 12", you must install the fireplace hood Vented Operation, page 10.  
accessory (24", 30" and 36" models only).  
Continued  
NOTICE: Manual control heaters  
maybeusedasaventedproduct.  
If so, you must always run heater  
with chimney flue damper open.  
If running heater with damper  
open, noncombustible material  
above fireplace opening is not  
needed. Go to Installing Damper  
Clamp Accessory for Vented Op-  
eration, page 10.  
Noncombustible  
Material Distance (A)  
Requirements for  
Safe Installation  
Minimum Noncombustible  
Material Clearances  
12" or more  
Noncombustible material OK.  
Between 8" and 12"  
24", 30", or 36" Models: Install fireplace hood ac-  
cessory (GA6050, GA6052 or GA6053 see Acces-  
sories, page 25).  
If Not Using Mantel  
Note: If using a mantel, proceed to If Using  
Mantel. If not using a mantel, follow the  
information below.  
18" Model: Noncombustible material OK.  
Less than 8"  
Noncombustible material must be extended to at  
least 8". See Between 8" and 12", above. If you  
cannot extend material, you must operate heater  
with flue damper open.  
You must have noncombustible material(s)  
above the fireplace opening. Noncombus-  
tible materials (such as slate, marble, tile,  
etc.) must be at least 1/2 inch thick. With  
sheet metal, you must have noncombustible  
material behind it. Noncombustible material  
must extend at least 8" up (for all models). If  
noncombustiblematerialislessthan12",you  
must install the fireplace hood accessory  
(24", 30" and 36" models only). See Figure 5  
at right for minimum clearances.  
Heat Resistant  
Material  
(A)  
IMPORTANT: If you cannot meet these  
minimum clearances, you must operate  
heater with chimney flue damper open. Go  
to Installing Damper Clamp Accessory for  
Vented Operation, page 10.  
Figure 5 - Heat Resistant Material (Slate,  
Marble, Tile, etc.) Above Fireplace  
105273  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Mantel Shelf  
Underside of  
Mantel Shelf  
INSTALLATION  
Continued  
MANTEL CLEARANCES  
10"  
8"  
6"  
2 1/2"  
In addition to meeting noncombustible ma-  
terial clearances, you must also meet re-  
quired clearances between fireplace opening  
and mantel shelf. If you do not meet the  
clearanceslistedbelow, youwillneed ahood.  
All minimum  
distances are  
in inches  
Minimum Non-  
Combustible  
Material  
(A)  
Log Set  
24"/30"/36" Models  
Determining Minimum Mantel  
Clearance  
12"  
8"  
18"  
8"  
20"  
14"  
22"  
24"  
163/4" 20"  
18" Model  
If you meet minimum clearance between  
mantel shelf and top of fireplace opening, a  
hood is not required (see Figure 6).  
Top of Fireplace  
Opening  
Minimum Non-  
Combustible  
Material Height  
Distances to  
Underside of  
Mantel  
Determining Minimum Mantel  
Clearance When Using a Hood  
If minimum clearances in Figure 6 are not  
met, you must have a hood. When using a  
hood there are still certain minimum mantel  
clearancesrequired.Followminimumclear-  
ances shown in Figure 7 when using hood.  
Figure 6 - Minimum Mantel Clearances Without Using Hood  
Mantel Shelf  
12"  
Underside of  
Mantel Shelf  
10"  
8"  
NOTICE: If your installation does  
notmeettheminimumclearances  
shown, you must do one of the  
following:  
• operate the logs only with the  
flue damper open  
• raise the mantel to an accept-  
able height  
• remove the mantel  
6"  
2 1/2"  
All minimum  
distances are  
in inches  
Minimum Non-  
Combustible  
Material  
Log Sets  
All Models  
8"  
Min.  
12"  
15"  
18"  
20"  
Top of Fireplace  
Opening  
FLOOR CLEARANCES  
Hood  
or GA6053)  
Distances to  
Underside of  
Mantel  
(GA6050, GA6052,  
A. If installing appliance on the floor level,  
you must maintain the minimum dis-  
tance of 14" to combustibles (see Fig-  
ure 8).  
B. If combustible materials are less than  
14" to the fireplace, you must install  
appliance at least 5" above the combus-  
tible flooring (see Figure 9).  
Figure 7 - Minimum Mantel Clearances When Using Hood  
Combustible  
Material  
Hearth  
Combustible  
14"  
Min.  
Material  
5"  
Min.  
Noncombustible Material  
Figure 9 - Minimum Fireplace Clearances  
Above Combustible Flooring  
Figure 8 - Minimum Fireplace Clearances  
If Installed at Floor Level  
Continued  
105273  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
See chart below for minimum permanent  
INSTALLING HEATER BASE  
ASSEMBLY  
INSTALLATION  
flue opening you must provide. Attach  
damper clamp so the minimum permanent  
flue opening will be maintained at all times.  
Continued  
INSTALLING DAMPER  
CLAMP ACCESSORY FOR  
VENTED OPERATION  
CAUTION: Do not remove the  
metal Data Plates attached to the  
heater base assembly. The Data  
Platescontainimportantwarranty  
information.  
Chimney  
Minimum Permanent  
Height (ft.) Flue Opening (sq. ins.)  
Note: When used as a vented heater, appli-  
ance must be installed only in a solid-fuel  
burning fireplace with a working flue and  
constructed of non combustible material.  
6' to 15'  
15' to 30'  
39 sq. inches  
29 sq. inches  
WARNING: You must secure  
this heater to fireplace floor. If  
not, heater will move when you  
adjust controls. Moving heater  
may cause a gas leak.  
Area of Various Standard  
Round Flues  
Ifyourheaterisamanuallycontrolledmodel,  
you may use this heater as a vented product.  
There are three reasons for operating your  
heater in the vented mode:  
Diameter (ins.)  
Area (sq. ins.)  
5"  
6"  
7"  
8"  
20 sq. inches  
29 sq. inches  
39 sq. inches  
51 sq. inches  
1. The fireplace does not meet the clear-  
ance to combustibles requirements for  
vent-free operation  
WARNING: If installing in a  
sunken fireplace, special care is  
needed. You must raise the fire-  
place floor to allow access to  
heater control panel. This will in-  
sure adequate air flow and guard  
against sooting. Raise fireplace  
floor with noncombustible mate-  
rial. Make sure material is secure.  
2. State or local codes do not permit vent-  
free operation  
3. You prefer vented operation  
Ifreasons number 1 or 2 above apply toyou,  
you must permanently open chimney flue  
damper. You must install the damper clamp  
accessory (to order, see Accessories, page  
25). This will insure vented operation (see  
Figure 10). The damper clamp will keep  
damper open. Installation instructions are  
included with clamp accessory.  
CAUTION: Do not pick up  
heater base assembly by the  
burner. This could damage  
heater. Only handle base assem-  
bly by grates.  
IMPORTANT:Makesuretheheaterburner  
is level. If heater is not level, heater will not  
work properly.  
Damper  
Clamp  
Damper  
Damper  
Clamp  
Damper  
Damper  
Masonry Fireplace  
Manufactured Fireplace  
Figure 10 - Attaching Damper Clamp  
105273  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
INSTALLATION  
Continued  
Installation Items Needed  
• hardware package (provided with heater)  
Flexible Gas  
Hose (if allowed  
by local codes)  
• approved flexible gas hose (not provided)  
(if allowed by local codes)  
Fitting  
• sealant (resistant to LP gas, not provided)  
• electric drill with 3/16" drill bit (metal  
or masonry as applicable)  
• flathead screwdriver  
1. Apply pipe joint sealant lightly to male  
threads of the fitting to be threaded into  
gas regulator. Connect approved flex-  
ible gas hose to gas regulator of heater  
(see Figure 11).  
Figure 11 - Attaching Flexible Gas Hose to Heater  
IMPORTANT: Hold gas regulator with  
wrench when connecting flexible gas  
hose.  
2. Locate two masonry screws in hard-  
ware package.  
Masonry Screw  
3. Place heater base in fireplace.  
4. Place logs in their proper position on  
heater base.  
5. Center heater base and logs front-to-  
back and side-to-side in fireplace.  
6. Carefully remove logs without moving  
heater base.  
7. Mark screw locations through one hole  
on each side of the mounting bracket  
(see Figure 12). If installing in a brick-  
bottom fireplace, mark screw locations  
in mortar joint of bricks.  
8. Remove heater base from fireplace.  
Mounting Flanges  
9. Drill holes at marked locations using  
3/16" drill bit.  
10. Attach base assembly to fireplace floor  
using two masonry screws (in hardware  
package).  
Figure 12 - Attaching Base Assembly to Fireplace Floor  
11. Connect to gas supply. See Connect-  
ing To Gas Supply, page 12.  
12. Replace logs on heater base.  
Continued  
105273  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
INSTALLATION  
WARNING: Never connect  
heater to private (non-utility) gas  
wells. This gas is commonly  
known as wellhead gas.  
CAUTION:Usepipejointseal-  
ant that is resistant to liquid pe-  
troleum (LP) gas.  
Continued  
CONNECTING TO GAS  
SUPPLY  
Installsedimenttrapinsupplylineasshown  
in Figure 13. Locate sediment trap where it  
is within reach for cleaning. Locate sedi-  
ment trap where trapped matter is not likely  
to freeze. A sediment trap traps moisture  
and contaminants. This keeps them from  
going into heater controls. If sediment trap  
is not installed or is installed wrong, heater  
may not run properly.  
CAUTION: Use only new,  
black iron or steel pipe. Inter-  
nally-tinned copper tubing may  
be used in certain areas. Check  
yourlocalcodes. Usepipeof1/2"  
diameter or greater to allow  
proper gas volume to heater. If  
pipe is too small, undue loss of  
pressure will occur.  
NOTICE: A qualified service per-  
son must connect heater to gas  
supply. Follow all local codes.  
Installation Items Needed  
Beforeinstallingheater,makesureyouhave  
the items listed below.  
• piping (check local codes)  
• sealant (resistant to LP gas)  
• manual shutoff valve *  
• test gauge connection *  
• sediment trap  
CAUTION: Avoid damage to  
control. Hold gas fitting with  
wrenchwhenconnectingittogas  
piping and/or fittings.  
Installation must include a manual shutoff  
valve, union, and plugged 1/8" NPT tap.  
Locate NPT tap within reach for test gauge  
hook up. NPT tap must be upstream from  
heater (see Figure 13).  
• tee joint  
• pipe wrench  
Apply pipe joint sealant lightly to male  
threads. This will prevent excess sealant  
from going into pipe. Excess sealant in pipe  
could result in clogged heater valves.  
* AnA.G.A.design-certifiedmanualshutoff  
valve with 1/8" NPT tap is an acceptable  
alternative to test gauge connection. Pur-  
chase the optional A.G.A. design-certified  
manual shutoff valve from your dealer. See  
Accessories, page 25.  
A.G.A. Design-Certified  
Manual Shutoff Valve With  
1/8" NPT Tap*  
Approved Flexible Gas  
Hose (if allowed by  
local codes)  
From Gas Meter (5"  
W.C.** to 10.5" W.C.  
Pressure)  
Gas Control  
Tee Joint  
Sediment  
Trap  
Pipe Nipple  
3" Minimum  
Cap  
Figure 13 - Gas Connection  
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.  
** Minimum inlet pressure for purpose of input adjustment.  
105273  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
TestPressuresEqualToorLessThan  
1/2 PSIG  
Pressure Testing Heater Gas  
Connections  
1. Open manual shutoff valve (see Fig-  
ure 14).  
INSTALLATION  
Continued  
1. Close manual shutoff valve (see Fig-  
ure 14).  
CHECKING GAS  
CONNECTIONS  
2. Pressurize supply piping system by ei-  
ther using compressed air or opening  
main gas valve located on or near gas  
meter.  
2. Open main gas valve located on or near  
gas meter.  
WARNING: Test all gas pip-  
ing and connections for leaks  
after installing or servicing. Cor-  
rect all leaks at once.  
3. Make sure control knob of heater is in  
the OFF position.  
3. Check all joints from gas meter to  
manual shutoff valve (see Figure 15).  
Apply mixture of liquid soap and wa-  
ter to gas joints. Bubbles forming show  
a leak.  
4. Check all joints from manual shutoff  
valve to control valve (see Figure 15).  
Apply mixture of liquid soap and wa-  
ter to gas joints. Bubbles forming show  
a leak.  
WARNING: Never use an  
open flame to check for a leak.  
Apply a mixture of liquid soap  
and water to all joints. Bubbles  
forming show a leak. Correct all  
leaks at once.  
4. Correct all leaks at once.  
5. Correct all leaks at once.  
6. Light heater (see Operating Heater,  
pages 15 through 17). Check all other  
internal joints for leaks.  
Manual  
Shutoff  
Valve  
Open  
7. Turn off heater (see To Turn Off Gas to  
Pressure Testing Gas Supply  
Piping System  
Appliance, page 16).  
TestPressuresInExcessOf1/2PSIG  
1. Disconnect heater and its individual  
manual shutoff valve from gas supply  
piping system. Pressures in excess of  
1/2 psig will damage heater regulator.  
Closed  
Figure 14 - Manual Shutoff Valve  
2. Cap off open end of gas pipe where  
manual shutoff valve was connected.  
Manual  
Shutoff  
Valve  
3. Pressurize supply piping system by ei-  
ther using compressed air or opening  
main gas valve located on or near gas  
meter.  
Control Valve Location  
4. Check all joints of gas supply piping  
system. Apply mixture of liquid soap  
and water to gas joints. Bubbles form-  
ing show a leak.  
Gas Meter  
5. Correct all leaks at once.  
6. Reconnect heater and manual shutoff  
valve to gas supply. Check reconnected  
fittings for leaks.  
Figure 15 - Checking Gas Joints  
Continued  
105273  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
INSTALLATION  
One Piece Log Set  
Continued  
INSTALLING LOGS  
WARNING: Failure to posi-  
tion the parts in accordance with  
these diagrams or failure to use  
only parts specifically approved  
withthisheatermayresultinprop-  
erty damage or personal injury.  
Middle  
CAUTION: After installation  
andperiodicallythereafter,check  
to ensure that no flame comes in  
contact with any log. With the  
heater set to High, check to see if  
flames contact any log. If so, re-  
position logs according to the  
loginstallationinstructionsinthis  
manual. Flames contacting logs  
will create soot.  
Section at  
Bottom of  
Log Set  
Burner  
Chassis  
Itisveryimportanttoinstallthelogsexactly  
as instructed. Do not modify logs. Only use  
logs supplied with heater.  
"U"-shaped  
Cutout in Chassis  
1. Place one-piece log set on grate to fit  
as illustrated in Figure 16. Make sure  
middle section at bottom of log set is  
seated into "U"-shaped cutout in cen-  
ter of chassis (see Figure 16). Log will  
fit securely on chassis. Note: 36" model  
has more features but fits on the chas-  
sis the same. IMPORTANT: Make sure  
log does not cover any burner ports.  
Figure 16 - Installing Golden Oak One-Piece Log Set  
One Piece  
Log Set  
Burner  
ports  
2. Place lava rock around base of heater.  
Figure 17 - Installing Golden Oak One-Piece Log Set (Top View)  
105273  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
LIGHTING  
INSTRUCTIONS  
OPERATING  
HEATER  
WARNING: Burner will come  
on automatically within one  
minute when the selector switch  
is in the ON position after the  
WARNING:  
FOR YOUR SAFETY  
• If fireplace has glass doors,  
never operate this heater with  
glass doors closed. If you op-  
erateheaterwithdoorsclosed,  
heat buildup inside fireplace  
will cause glass to burst. Also  
if fireplace opening has vents  
at the bottom, you must open  
the vents before operating  
heater.  
pilot is lit.  
READ BEFORE  
LIGHTING  
4. Press in and turn control knob clock-  
wise  
to the OFF position.  
WARNING: If you do not fol-  
low these instructions exactly, a  
fireorexplosionmayresultcaus-  
ing property damage, personal  
injury or loss of life.  
5. Wait five (5) minutes to clear out any  
gas. Then smell for gas, including  
near the floor. If you smell gas,  
STOP! Follow “B” in the safety in-  
formation. If you don’t smell gas, go  
to the next step.  
A. This appliance has a pilot which must  
be lighted by hand. When lighting the  
pilot, follow these instructions exactly.  
• You must operate this heater  
withafireplacescreeninplace.  
Make sure fireplace screen is  
closed before running heater.  
6. Press in and turn control knob coun-  
terclockwise  
position. Press in control knob for  
five (5) seconds (see Figure 18).  
to the PILOT  
B. BEFORE LIGHTING smell all  
around the appliance area for gas. Be  
sure to smell next to the floor because  
some gas is heavier than air and will  
settle on the floor.  
Note: You may be running this  
heater for the first time after hook-  
ing up to gas supply. If so, the con-  
trol knob may need to be pressed in  
for 30 seconds or more. This will al-  
low air to bleed from the gas system.  
NOTICE: During initial operation  
of new heater, burning logs will  
give off a paper-burning smell.  
Open damper or window to vent  
smell. This will only last a few  
hours.  
WHAT TO DO IF YOU SMELL  
GAS  
• Do not try to light any appliance.  
• Do not touch any electric switch;  
do not use any phone in your building.  
• Immediately call your gas supplier  
from a neighbor’s phone. Follow  
the gas supplier’s instructions.  
• If you cannot reach your gas sup-  
plier, call the fire department.  
7. With control knob pressed in, press  
and release ignitor button. This will  
light pilot. The pilot is attached to the  
front burner. If needed, keep press-  
ing ignitor button until pilot lights.  
Note: Home owners generally prefer to  
operate their heater with the chimney  
damper closed. This will put all the heat  
into the room. However, there may be  
times you will desire the full flames of  
the High heat setting but will find the  
heat output excessive. You can open the  
chimney damper (if you have one) fully  
or partially to release some of the heat.  
Note: If pilot does not stay lit, con-  
tact a qualified service person or gas  
supplier for repairs. Until repairs are  
made, light pilot with match. To light  
pilot with match, see Manual Light-  
ing Procedure on page 16.  
C. Use only your hand to push in or turn  
the gas control knob. Never use tools.  
If the knob will not push in or turn  
by hand, don’t try to repair it, call a  
qualified service technician or gas  
supplier. Force or attempted repair  
may result in a fire or explosion.  
WARNING: Damper handle  
will be hot if heater has been  
running.  
D. Do not use this appliance if any part  
has been under water. Immediately  
call a qualified service technician to  
inspect the appliance and to replace  
any part of the control system and  
any gas control which has been un-  
der water.  
1. STOP! Read the safety information,  
column 1.  
2. Make sure manual shutoff valve is  
fully open.  
3. Set switch to OFF position.  
Flame Adjustment Knob  
Control Knob  
I
AUTO  
OFF  
ON  
O
N O  
I
T O  
O
Selector Switch in OFF Position  
Ignitor Button  
Figure 18 - Control Knob and Ignitor Button Location (Shown as Supplied,  
No Control Options)  
Continued  
105273  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
For wall thermostat operation, follow in-  
TO TURN OFF GAS  
TO APPLIANCE  
OPERATING  
struction supplied with thermostat acces-  
sory GWMT1. For wall switch operation  
followinstructionssuppliedwithGWMS2.  
HEATER  
Shutting Off Heater  
Continued  
1. Turn control knob clockwise  
to the OFF position.  
8. Keep control knob pressed in for 30  
seconds after lighting pilot. After 30  
seconds, release control knob.  
• If control knob does not pop out  
when released, contact a qualified  
service person or gas supplier for  
repairs.  
NOTICE: You must light the pilot  
before using the hand-held re-  
mote control unit. See Lighting  
Instructions on page 15.  
2a. Set selector switch in the OFF position.  
2b. If Using Optional Hand-Held Re-  
mote: Set selector switch in the OFF  
position to keep from draining battery.  
1. After lighting, let pilot flame burn for  
about one minute. Turn control knob  
to ON position. Adjust flame adjust-  
ment knob anywhere between HI  
and LO. Slide the selector switch to  
the REMOTE position. Note: The  
burner may light if hand-held remote  
ON button was on when selector  
switch was last turned off. You can  
now turn the burner on and off with  
the hand-held remote control unit.  
Note: If pilot goes out, repeat steps  
4 through 8.  
Shutting Off Burner Only (pilot  
stays lit)  
9. Slightly push in and turn control  
Youmayshutofftheburnerandkeepthe  
pilot lit by doing one of the following:  
knob counterclockwise  
the ON position.  
to  
1. Turn control knob clockwise  
to the PILOT position.  
10. Wait one minute and switch selector  
switch to the ON position to light  
burner. Note:AUTO is only functional  
when using GWMT1 or GWMS2 op-  
tional accessories.  
2. UseremotecontrolmanualOFFbutton.  
3. Set selector switch in the OFF position.  
IMPORTANT: Do not leave the se-  
lector switch in the REMOTE posi-  
tion when the pilot is not lit. This will  
drain the battery.  
MANUAL LIGHTING  
PROCEDURE  
1. Follow steps 1 through 6 under Light-  
11. Set flame adjustment knob to any  
level between HI and LO.  
IMPORTANT: Be sure to press the  
ON/OFF buttons on the hand held  
remote control unit for up to 3 sec-  
onds to assure proper operation.  
ing Instructions, page 15.  
CAUTION:Donottrytoadjust  
heating levels by using the  
manual shutoff valve.  
2. Depress control knob and light pilot  
with match.  
3. Keep control knob pressed in for 30  
seconds after lighting pilot. After 30  
seconds, release control knob. Now  
follow steps 9 through 11.  
WARNING: Make sure the  
selector switch is in the OFF po-  
sition when you are away from  
home for long periods of time.  
Heater will come on automati-  
cally with selector switch in the  
ON position.  
GHRC Operation:  
2a. Press the ON/OFF button to turn the  
burner on and off. When turning  
burner off, the pilot will remain lit.  
OPTIONAL REMOTE  
OPERATION  
GHRCT Operation:  
2b. Select the MAN (manual) or AUTO  
button on the hand-held remote con-  
trol unit (see Figure 21, page 17).  
• In manual mode, turn burner on  
or off by pressing the ON or OFF  
buttons on the hand-held remote  
control unit.  
Note:Allremotecontrolaccessoriesmust  
bepurchasedseparately(seeAccessories,  
page 25). Follow instructions included  
with the remote control.  
Pilot Burner  
Ignitor Electrode  
Thermostat Control Operation  
(Optional GHRCT Only) The thermo-  
stat control setting on the remote control  
unit can be set to any comfort level be-  
tween HI and LO. The burner will turn  
on and off automatically to maintain the  
comfort level you select. The ideal com-  
fort setting will vary by household de-  
pending upon the amount of space to be  
heated, the output of the central heating  
system, etc.  
• In auto mode, the room tempera-  
ture is controlled by the thermostat  
in the hand-held remote control  
unit.To increase the room tempera-  
ture, press the top arrow of the  
TEMP button. To lower room the  
temperature, press the bottom ar-  
row of theTEMP button.At higher  
settings the heater will run longer.  
Figure 19 - Pilot  
105273  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
3. Use the STATUS button on the hand-  
OPERATING  
INSPECTING  
BURNERS  
held remote control unit to see the  
operation mode being used and the  
temperature setting selected. A red  
light will come on beside the opera-  
tion mode being used when the sta-  
tus button is pressed.  
HEATER  
Continued  
Check pilot flame pattern and burner flame  
patterns often.  
IMPORTANT: This remote control  
has been specially engineered to  
take an air temperature sample ev-  
ery 5.5 minutes in theAUTO mode.  
It will not respond immediately to  
the temperature setting being  
turned up or down.  
IMPORTANT: The hand-held re-  
mote control unit must be near the  
heater. Do not keep the hand-held  
remote control unit too close the  
heater. The thermostat on the  
hand-held remote control unit will  
heat up too quickly and turn the  
heater off.  
PILOT FLAME PATTERN  
4. To turn the burner off when operating  
in the manual mode, press the OFF  
button. If operating in the auto mode,  
press the MAN button, then press the  
OFF button. The pilot will remain lit.  
IMPORTANT: To turn the pilot off,  
manually turn the control knob on the  
heater to the OFF position.  
Figure 22 shows a correct pilot flame pat-  
tern.Figure23showsanincorrectpilotflame  
pattern.Theincorrectpilotflameisnottouch-  
ing the thermocouple. This will cause the  
thermocouple to cool. When the thermo-  
couple cools, the heater will shut down.  
If pilot flame pattern is incorrect, as shown  
in Figure 23  
• turn heater off (see To Turn Off Gas to  
Appliance, page 16)  
see Troubleshooting, pages 19 through 21  
Thermocouple  
Control Knob in  
On Position  
Pilot Burner  
Flame Adjustment Knob  
P
F
ON  
OFF  
REMOTE  
O
Figure 22 - Correct Pilot Flame Pattern  
Pilot Burner  
Selector Switch in Remote Position (Optional  
Remote Control)  
Thermocouple  
Figure 20 - Setting the Selector Switch, Control Knob, and Flame  
Adjustment Knob for Remote Operation  
Figure 23 - Incorrect Pilot Flame Pattern  
Shows Temperature Setting  
HI  
Increases Room  
Temperature  
BURNER PRIMARY AIR HOLES  
Air is drawn into the burner through the  
holes in the fitting at the burner entrance.  
These holes may become blocked with dust  
or lint. Periodically inspect these holes for  
any blockage and clean if needed. Blocked  
air holes will create soot.  
TEMP  
Decreases Room  
Temperature  
Allows Burner to be Turned  
On and Off with the Hand-  
Held Remote Unit.  
LO  
MAN  
ON  
Turns Burner On  
and Off  
AUTO  
OFF  
The log heater will  
automatically cycle between  
pilot and the heat setting that  
has been selected.  
MAIN BURNER  
Shows Current  
Operation Mode  
STATUS  
Periodically inspect all burner flame holes  
with the heater running. All slotted burner  
flame holes should be open with yellow  
flame present. All round burner flame holes  
should be open with a small blue flame  
present. Some burner flame holes may be-  
comeblockedbydebrisorrust,withnoflame  
present. If so, turn off heater and let cool.  
Either remove blockage or replace burner.  
Blocked burner flame holes will create soot.  
Figure 21 - Thermostat Hand-Held Remote Control Unit Selections  
105273  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
4. Check the injector holder located at the  
LOGS  
CLEANING AND  
end of the burner tube again. Remove  
• If you remove logs for cleaning, refer to  
Installing Logs, page 14, to properly re-  
place logs.  
MAINTENANCE  
any large particles of dust, dirt, lint, or  
pet hairs with a soft cloth or vacuum  
cleaner nozzle.  
WARNING: Turn off heater  
and let cool before cleaning.  
• Replace log(s) if broken or chipped  
(dime-sized or larger).  
5. Blow air into the primary air holes on  
the injector holder.  
6. In case any large clumps of dust have MAIN BURNER  
CAUTION: You must keep  
control areas, burner, and circu-  
lating air passageways of heater  
clean. Inspect these areas of  
heater before each use. Have  
heaterinspectedyearlybyaquali-  
fied service person. Heater may  
needmorefrequentcleaningdue  
to excessive lint from carpeting,  
pet hair, bedding material, etc.  
now been pushed into the burner repeat  
Periodically inspect all burner flame holes  
steps 3 and 4.  
with the heater running. All slotted burner  
flame holes should be open with yellow  
flame present. All round burner flame holes  
should be open with a small blue flame  
present. Some burner flame holes may be-  
come blocked by debris or rust, with no  
flame present. If so, turn off heater and let  
cool. Either remove blockage or replace  
burner. Blocked burner flame holes will  
create soot.  
Clean the pilot assembly also. A yellow tip  
on the pilot flame indicates dust and dirt in  
the pilot assembly. There is a small pilot air  
inlet hole about two inches from where the  
pilot flame comes out of the pilot assembly  
(see Figure 25). With the unit off, lightly  
blow air through the air inlet hole. You may  
blowthroughadrinkingstrawifcompressed  
air is not available.  
CLEANING BURNER  
INJECTOR HOLDER AND  
PILOT AIR INLET HOLE  
Injector Holder  
Burner  
(May Be Brass  
Tube  
or Aluminum  
Depending on  
Model)  
The primary air inlet holes allow the proper  
amount of air to mix with the gas. This  
provides a clean burning flame. Keep these  
holesclearofdust, dirt, andlint. Cleanthese  
air inlet holes prior to each heating season.  
Blocked air holes will create soot. We rec-  
ommend that you clean the unit every 2,500  
hours of operation or every three months.  
Primary Air Inlet  
Holes (Shape of  
Holes May Vary  
by Model)  
Wealsorecommendthatyoukeeptheburner  
tube and pilot assembly clean and free of  
dustanddirt.Tocleanthesepartswerecom-  
mend using compressed air no greater than  
30 PSI. Your local computer store, hard-  
ware store, or home center may carry com-  
pressed air in a can. You can use a vacuum  
cleaner in the blow position. If using com-  
pressed air in a can, please follow the direc-  
tions on the can. If you don't follow direc-  
tions on the can, you coulddamage the pilot  
assembly.  
Figure 24 - Injector Holder On Outlet  
Burner Tube  
Ports/Slots  
Burner  
Tube  
Pilot  
Assembly  
1. Shut off the unit, including the pilot.  
Allow the unit to cool for at least thirty  
minutes.  
Pilot Air  
Inlet Hole  
2. Inspect burner, pilot, and primary air  
inlet holes on injector holder for dust  
and dirt (see Figure 24).  
3. Blow air through the ports/slots and  
holes in the burner.  
Figure 25 - Pilot Inlet Air Hole  
105273  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
TROUBLESHOOTING  
Note: For additional help, visit DESA  
International’stechnicalservicewebsite  
WARNING: Turn off heater  
CAUTION: Never use a wire,  
needle, or similar object to clean  
ODS/pilot.ThiscandamageODS/  
pilot unit.  
andletcoolbeforeservicing.Only  
aqualifiedservicepersonshould  
service and repair heater.  
Note:Alltroubleshootingitemsarelistedin  
order of operation.  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
When ignitor button is pressed, there is no  
spark at ODS/pilot  
1. Ignitor electrode not connected to igni- 1. Reconnect ignitor cable  
tor cable  
2. Ignitor cable pinched or wet  
2. Free ignitor cable if pinched by any  
metal or tubing. Keep ignitor cable dry  
3. Tighten nut holding piezo ignitor to base  
panel of log set. Nut is located behind  
base panel.  
3. Piezo ignitor nut is loose  
4. Broken ignitor cable  
4. Replace ignitor cable  
5. Bad piezo ignitor  
5. Replace piezo ignitor  
6. Ignitor electrode broken  
7. Ignitor electrode positioned wrong  
6. Replace piezo ignitor  
7. Replace piezo ignitor  
When ignitor button is pressed, there is  
spark at ODS/pilot but no ignition  
1. Gas supply turned off or manual shutoff 1. Turn on gas supply or open manual  
valve closed  
shutoff valve  
2. Control knob not in PILOT position  
2. Turn control knob to PILOT position  
3. Control knob not pressed in while in 3. Press in control knob while in PILOT  
PILOT position  
position  
4. Air in gas lines when installed  
4. Continue holding down control knob.  
Repeat igniting operation until air is  
removed  
5. ODS/pilot is clogged  
5. Clean ODS/pilot (see Cleaning and  
Maintenance, page 18) or replace ODS/  
pilot assembly  
6. Gas regulator setting is not correct  
1. Control knob not fully pressed in  
6. Replace gas control  
ODS/pilot lights but flame goes out when  
control knob is released  
1. Press in control knob fully  
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control  
knob pressed in 30 seconds  
3. Manual shutoff valve not fully open  
3. Fully open manual shut-off valve  
4. Pilot flame not touching thermocouple, 4. A) Contact local natural gas company  
which allows thermocouple to cool,  
causing pilot flame to go out. This prob-  
lem could be caused by one or both of  
the following:  
B) Clean ODS/pilot (see Cleaning and  
Maintenance, page 18) or replace ODS/  
pilot assembly  
A) Low gas pressure  
B) Dirty or partially clogged OD S/pilot  
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten  
trol valve  
1/4 turn more  
6. Thermocouple damaged  
6. Replace thermocouple  
7. Control valve damaged  
7. Replace control valve  
Continued  
105273  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
TROUBLESHOOTING  
Continued  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Burner does not light after ODS/pilot is lit  
1. Burner orifice clogged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 18) or replace burner orifice  
2. Contact local natural gas company  
3. Replace burner orifice  
2. Inlet gas pressure is too low  
3. Burner orifice diameter is too small  
4. Thermopile leads disconnected or im- 4. Reconnect leads (see Wiring Diagram,  
properly connected page 24)  
5. Burners will not come on in remote po- 5. Replace battery in transmitter and re-  
sition  
ceiver  
Delayed ignition burner  
1. Manifold pressure is too low  
2. Burner orifice clogged  
1. Contact local natural gas company  
2. Clean burner (see Cleaning and Mainte-  
nance, page 18) or replace burner orifice  
Burner backfiring during combustion  
1. Burner orifice is clogged or damaged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 18) or replace burner orifice  
2. Replace damaged burner  
2. Damaged burner  
3. Gas regulator defective  
3. Replace gas control  
Slightsmokeorodorduringinitialoperation 1. Not enough air  
1. Check burner for dirt and debris. If  
found, clean burner (see Cleaning and  
Maintenance, page 18)  
2. Gas regulator defective  
2. Replace gas control  
3. Residues from manufacturing processes 3. Problem will stop after a few hours of  
and logs curing  
operation  
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air  
1. Refer to Air for Combustion and Venti-  
lation requirements (page 4)  
Heater produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and  
burner is lit  
when burner is cold  
2. Air in gas line  
let warm up for a minute  
2. Operate burner until air is removed from  
line. Have gas line checked by local  
natural gas company  
3. Air passageways on heater blocked  
3. Observe minimum installation clear-  
ances (see pages 7 through 9)  
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-  
nance, page 18) or replace burner orifice  
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture  
box or on adjacent walls or furniture  
ish, wax, carpet cleaners, etc. turn into  
white powder residue  
polish, wax, carpet cleaners, or similar  
products  
Remote does not function  
1. Battery is not installed. Battery power 1. Replace 9-volt batteries in receiver and  
is low remote control  
105273  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
TROUBLESHOOTING  
Continued  
WARNING: If you smell gas  
• Shut off gas supply.  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not use any phone in  
your building.  
• Immediately call your gas supplier from a neighbor’s phone.  
Follow the gas supplier’s instructions.  
• Ifyoucannotreachyourgassupplier,callthefiredepartment.  
IMPORTANT: Operating heater where impurities in air exist may create odors.  
Cleaningsupplies,paint,paintremover,cigarettesmoke,cementsandglues,new  
carpet or textiles, etc., create fumes. These fumes may mix with combustion air  
and create odors. These odors will disappear over time.  
POSSIBLE CAUSE  
OBSERVED PROBLEM  
REMEDY  
1. Metal expanding while heating or con-  
tracting while cooling  
Heater produces a clicking/ticking noise  
just after burner is lit or shut off  
1. This is common with most heaters. If  
noise is excessive, contact qualified ser-  
vice person  
1. Heater burning vapors from paint, hair  
spray, glues, cleaners, chemicals, new  
carpet, etc. (See IMPORTANT state-  
ment above)  
Heater produces unwanted odors  
1. Open window and ventilate room. Stop  
using odor causing products while heater  
is running  
2. Gas leak. SeeWarning statement at  
top of page  
2. Locate and correct all leaks (see Check-  
ing Gas Connections, page 13)  
1. Not enough fresh air is available  
2. Low line pressure  
3. ODS/pilot is partially clogged  
Heater shuts off in use (ODS operates)  
1. Open window and/or door for ventilation  
2. Contact local natural gas company  
3. Clean ODS/pilot (see Cleaning and  
Maintenance, page 18)  
1. Gas leak. SeeWarning statement at  
top of page  
2. Control valve defective  
Gas odor even when control knob is in OFF  
position  
1. Locate and correct all leaks (see Check-  
ing Gas Connections, page 13)  
2. Replace control valve  
1. Foreign matter between control valve  
and burner  
Gas odor during combustion  
1. Take apart gas tubing and remove for-  
eign matter  
2. Gas leak. SeeWarning statement at  
top of page  
2. Locate and correct all leaks (see Check-  
ing Gas Connections, page 13)  
105273  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
ILLUSTRATED  
PARTS  
BREAKDOWN  
FLAME-MAX® GOLDEN OAK  
LOG MODELS VYD18NRA,  
VYD24NRA, VYD30NRA, AND  
VYD36NR  
1
*Note: The Golden Oak Log (104254-01)  
for the VYD36NR model differs slightly  
from the log shown.  
2
23  
3
6
7
4
9
8
5
23  
10  
24  
12  
11  
13  
25  
I
H
18  
L
O
O
F
14  
F
N
O
T
I P  
O
L
17  
13  
22  
15  
16  
19  
26  
19  
20  
I
H
L
O
O
F
N
F
O
L I P  
T
O
13  
21  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
105273  
OWNER’S MANUAL  
This list contains replaceable parts used in your heater. When ordering parts, follow the  
instructions listed under Replacement Parts on page 24 of this manual.  
PARTS LIST  
VYD18NRA, VYD24NRA,  
VYD30NRA, AND VYD36NR  
KEY  
NO.  
PART NUMBER FOR  
VYD18NRA  
VYD24NRA  
VYD30NRA  
VYD36NR  
DESCRIPTION  
QTY.  
1
2
3
4
5
6
7
8
9
10  
105268-01  
103779-01  
098249-01  
104422-01  
098264-02  
102843-01  
099056-26  
105268-02  
103779-01  
098249-01  
103342-01  
098264-02  
102843-01  
099056-16  
102966-01  
102772-01  
099387-12  
105268-03  
103779-01  
098249-01  
103342-01  
098264-02  
102843-01  
099056-16  
102966-01  
102772-01  
099387-12  
104254-01  
103779-01  
098249-01  
103342-01  
098264-02  
102843-01  
099056-16  
102966-01  
102772-01  
099387-12  
Log, Golden Oak  
ODS Pilot (NG)  
ODS Nut  
Burner Outlet Tube  
Male Connector  
Burner Clip  
Burner Orifice Injector  
Upper Bracket  
Burner  
1
1
2
1
1
1
1
1
1
102980-01  
099387-15  
Pilot Tube  
(Valve to regulator)  
Gas Control Valve  
Lower Bracket  
Screw, #8 x .38  
Painted Base Assy  
Ignitor Cable  
Piezo Ignitor  
Plate, Switch  
Heat Shield  
Screw  
1
1
1
7
1
1
1
1
1
2
1
1
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
103781-01  
103345-02  
M11084-38  
104384-01  
098271-07  
102445-01  
103587-02  
104099-01  
098304-01  
103784-02  
103784-01  
M12461-26  
103781-01  
103345-01  
M11084-38  
102775-06CK  
098271-07  
102445-01  
103587-02  
104099-01  
098304-01  
103784-02  
103784-01  
M12461-26  
103781-01  
103345-01  
M11084-38  
102775-08CK  
098271-07  
102445-01  
103587-02  
104099-01  
098304-01  
103784-02  
103784-01  
M12461-26  
103781-01  
103345-01  
M11084-38  
102775-08CK  
098271-07  
102445-01  
103587-02  
104099-01  
098304-01  
103784-02  
103784-01  
M12461-26  
Flame Adjustment Knob  
Off-Pilot-On Knob  
Screw, Hex Slt Wsr  
10-32 x .38  
4
23  
100609-01  
100609-01  
100609-01  
100609-01  
Pilot Tube  
(Regulator to Pilot)  
Pilot Regulator  
Wiring Harness  
Switch  
1
1
1
1
24  
25  
26  
099918-02  
103284-02  
099998-01  
099918-02  
103284-02  
099998-01  
099918-02  
103284-02  
099998-01  
099918-02  
103284-02  
099998-01  
PARTS AVAILABLE — NOT SHOWN  
100563-01  
103877-01  
100563-01  
103877-01  
100563-01  
103877-01  
100563-01  
103877-01  
Warning Plate  
Lighting Instructions  
Plate  
Warning Plate Fastener  
Caution Decal  
Hardware Kit  
1
1
1
1
1
1
1
100565-01  
100693-01  
101137-02  
104310-01  
GA6060  
100565-01  
100639-01  
101137-02  
104310-08  
GA6060  
100565-01  
100639-01  
101137-02  
104310-08  
GA6060  
100565-01  
100639-01  
101137-02  
104310-08  
GA6060  
Information Video  
Lava Rock  
105273  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VANGUARD FLAME MAX®  
UNVENTED NATURAL GAS LOG HEATER  
WIRING DIAGRAM  
Note: For proper operation of optional ac-  
cessories, the wires from the switch to the  
controlmustbeconnectedexactlyasshown.  
REPLACEMENT  
PARTS  
Note: Use only original replacement parts.  
Thiswillprotectyourwarrantycoveragefor  
parts replaced under warranty.  
PARTS UNDER WARRANTY  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s), call DESA International’s Techni-  
cal Service Department at  
1-800-323-5190. When calling DESA In-  
ternational, have ready  
AUT  
O
OFF  
ON  
• your name and address  
• model and serial numbers of your heater  
• how heater was malfunctioning  
• type of gas used (propane or natural gas)  
• purchase date  
Thermopile  
Usually, we will ask you to return the defec-  
tive part to the factory.  
SPECIFICATIONS  
PARTS NOT UNDER  
WARRANTY  
Golden Oak  
Golden Oak  
24", 30", and 36"  
Remote Ready  
18" Remote  
Ready  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s), call DESA International’s Parts  
Department at 1-800-972-7879 for referral  
information. When calling DESA Interna-  
tional, have ready  
Btu (Variable)  
Type Gas  
Ignition  
16,000/30,000  
Natural Gas Only  
Piezo  
20,000/39,000  
Natural Gas Only  
Piezo  
Pressure Manifold  
Inlet Gas Pressure (in. of water)  
Maximum  
3.5" W.C.  
3.5" W.C.  
• model number of your heater  
• the replacement part number  
10.5"  
5"  
10.5"  
5"  
Minimum*  
Shipping Weight  
28 lbs.  
30 lbs. (24")/32 lbs. (30")  
34 lbs. (36")  
* For input adjustment  
SERVICE HINTS  
TECHNICAL  
SERVICE  
When Gas Pressure Is Too Low  
• pilot will not stay lit  
You may have further questions about in-  
stallation, operation, or troubleshooting.  
• burners will have delayed ignition  
• heater will not produce specified heat  
If so, contact DESA International’s Techni-  
calServiceDepartmentat1-800-DESALOG  
(1-800-337-2564).  
When Gas Quality Is Bad  
• pilot will not stay lit  
You can also visit DESA International’s  
technical services web site at  
• burners will produce flames and soot  
• heater will backfire when lit  
Youmayfeelyourgaspressureistoolowor  
gas quality is bad. If so, contact your local  
natural gas supplier.  
105273  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
WALL-MOUNT THERMOSTAT  
SWITCH - GWMT1  
(Not Shown)  
HI  
ACCESSORIES  
TEMP  
MAN  
LO  
AU  
T
O
ON  
Purchasetheseheateraccessoriesfromyour  
local dealer. If they can not supply these  
accessories,callDESAInternational’sParts  
Department at 1-800-972-7879 for referral  
information. You can also write to the ad-  
dress listed on the back page of this manual.  
OFF  
ST  
A
TUS  
For all models. The desired comfort setting  
can be selected on the wall thermostat and  
the log heater will automatically cycle from  
pilot to the heat setting selected.  
RECEIVER AND HAND-HELD  
THERMOSTAT REMOTE  
CONTROL KIT - GHRCT  
WALL-MOUNT ON/OFF  
SWITCH - GWMS2  
(Not Shown)  
For all models. Allows the gas log heater to  
be operated in a manually or thermostati-  
cally controlled mode. You can turn the gas  
log heater on and off without ever leaving  
the comfort of your easy chair.  
For all models. Allows the gas log heater to  
be turned on and off with a wall switch.  
DAMPER CLAMP - GA6080  
(Not Shown)  
Permanently opens chimney flue damper  
for vented operation. Can be used only with  
non-thermostat accessories.  
LAVA ROCK - GA6060  
(Not Shown)  
MANUAL SHUTOFF VALVE -  
GA5010  
For all models. Order when additional rock  
is desired. (3 lb. bag)  
Forallmodels.Manualshutoffvalvewith1/8"  
NPT tap. Fits 1/2" NPT pipe.  
RECEIVER AND HAND-  
HELD REMOTE CONTROL  
KIT - GHRC  
Forallmodels.Allowsthegaslogheaterto  
be turned on and off by using a hand-held  
remote control.  
FIREPLACE HOOD  
Black - GA6050  
Brass - GA6052  
Antique Brass - GA6053  
For all models. Helps deflect heat away  
from mantel or wall above fireplace. Fits  
openings 28" to 48" wide.  
105273  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
KEEP THIS WARRANTY  
Model  
Serial No.  
Date Purchased  
Always specify model and serial numbers when communicating with the factory.  
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written  
warranty. We make no other warranty, expressed or implied.  
LIMITED WARRANTY  
VENT-FREE NATURAL GAS LOG HEATERS  
DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first  
purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.  
To make a claim under this warranty the Bill of Sale or cancelled check must be presented.  
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater  
toproperoperatingconditionandanallowanceforlaborwhenprovidedbyaDESAAuthorizedServiceCenter. Warrantypart(s)MUST  
be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts.  
Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer inaccordance  
with all local codes and instructions furnished with the unit.  
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become  
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,  
labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.  
TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT;  
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-  
TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS  
FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE;  
AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND  
DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT,  
INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential  
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.  
For information about this warranty write:  
INTERNATIONAL  
2701 Industrial Drive  
P.O. Box 90004  
Bowling Green, KY 42102-9004  
105273 01  
105273-01  
Rev. C  
09/99  
NOT A UPC  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TC electronic SDN BHD Network Card DVR2 User Manual
Teac CD Player Compact Disc Player User Manual
Telos Network Router iPort User Manual
Topcom Computer Drive 4001G User Manual
Toshiba Cash Register MA 1060 User Manual
Trane Heat Pump 2TWA0 User Manual
TRENDnet Network Card 18 1106 33 User Manual
Triarch Indoor Furnishings 29766 User Manual
Uniden Cordless Telephone EXI7960 User Manual
Wayne Dalton Universal Remote WDHC 20 User Manual