TRUE FOOD SERVICE EQUIPMENT, INC.
St. Charles Industrial Center • P.O. Box 970 • O’Fallon, Missouri 63366
(636)-240-2400 • FAX (636)272-2408 • (800)325-6152
Parts Department (800)424-TRUE • Parts Department FAX# (636)272-9471
INSTALLATION MANUAL FOR CHEF BASE EQUIPMENT
TABLE OF CONTENTS
Safety Information
Safety Precautions
Proper Disposal
Connecting Electricity
Adapter Plugs
1
2
3
3
TRCB-52
Installation / Operation Instructions
Ownership
4
4
4
5
6
7
8
Required Tools
Uncrating
Locating & Installation of Leg/Castors
Leveling Cabinet & Electrical Inst.
Wire Gauge Chart
Start-up
Maintenance, Care & Cleaning
Cleaning Condenser Coil
9-10
11
Temperature Control Adjustment
Stainless Steel Equipment Care & Cleaning 12-13
Warranty (U.S.A. & Canada Only!)
14
TRCB-82
*Spanish, German, French, and Dutch versions included.
CONGRATULATIONS!
You have just purchased the finest commercial
refrigerator available. You can expect many years of
trouble-free operation.
(TRCB MODELS) CHEF BASE
EQUIPMENT
9/19/08-3k SB #897012
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
How to Maintain Your
Unit to Receive the Most Efficient
and Successful Operation
You have selected one of the finest commercial refrigeration units made.
It is manufactured under strict quality controls with only the best quality
materials available. Your TRUE cooler when properly maintained will give
you many years of trouble-free service.
WARNING!
Use this appliance for its intended purpose as described in
this Owner Manual.
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
This refrigerator must be properly installed and
located in accordance with the Installation
Instructions before it is used.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
Do not allow children to climb, stand or hang on the
shelves in the refrigerator. They could damage the
refrigerator and seriously injure themselves.
Unplug the refrigerator before cleaning and
making repairs.
Setting temperature controls to the 0 position does
not remove power to the evaporator fans.
Do not touch the cold surfaces in the refrigerator
compartment when hands are damp or wet. Skin
may stick to these extremely cold surfaces.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Keep fingers out of the “pinch point” areas; clearances
between the doors and between the doors and cabinet
are necessarily small; be careful closing doors when
children are in the area.
1
1
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
DANGER!
RISK OF CHILD ENTRAPMENT
PROPER DISPOSAL OF THE REFRIGERATOR
Child entrapment and suffocation are not problems of
the past. Junked or abandoned refrigerators are still
dangerous… even if they will sit for “just a few days.” If
you are getting rid of your old refrigerator, please follow
Refrigerant Disposal
Your old refrigerator may have a cooling system that
uses “Ozone Depleting ” chemicals. If you are throwing
away your old refrigerator, make sure the refrigerant
is removed for proper disposal by a qualified service
technician. If you intentionally release any refrigerants
you can be subject to fines and imprisonment under
provisions of the environmental regulations.
the instructions below to help
prevent accidents.
Before You Throw Away Your Old Refrigerator
or Freezer:
Take off the doors.
Leave the shelves in place so that children may not
easily climb inside.
USE OF EXTENSION CORDS
NEVER USE AN EXTENSION CORD! TRUE will not warranty any refrigerator that has been
connected to an extension cord.
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
WARNING!
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
Repair or replace immediately all power cords that have
become frayed or otherwise damaged. Do not use a cord
that shows cracks or abrasion damage along its length or
at either end.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
When removing the refrigerator away from the wall, be
careful not to roll over or damage the power cord.
If the outlet is a standard 2-prong outlet, it is your
personal responsibility and obligation to have it replaced
with the properly grounded 3-prong wall outlet.
The refrigerator should always be plugged into it’s own
individual electrical circuit, which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading building wiring circuits which could cause a
fire hazard from overheated wires.
Never unplug your refrigerator by pulling on the power
cord. Always grip plug firmly and pull straight out
from the outlet.
USE OF ADAPTER PLUGS
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under certain conditions, we
strongly recommend against the use of an adapter plug.
(North America Use Only!)
NEMA plugs
TRUE uses these types of plugs. If you
do not have the right outlet have a
certified electrician install the correct
power source.
3
3
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION / OPERATION INSTRUCTIONS
OWNERSHIP
To insure that your unit works properly from the
first day, it must be installed properly. We highly
recommend a trained refrigeration mechanic and
electrician install your True equipment. The cost of a
professional installation is money well spent.
Before you start to install your True unit, carefully
inspect it for freight damage. If damage is discovered,
immediately file a claim with the delivery freight carrier.
True is not responsible for damage incurred
during shipment.
REQUIRED TOOLS
Adjustable Wrench
Phillips Head Screwdriver
Level
UNCRATING
Step 1
The following procedure is recommended for uncrating
the unit:
A. Remove the outer packaging, (cardboard and bubbles
or styrofoam corners and clear plastic). Inspect for
concealed damage. Again, immediately file a claim
with the freight carrier if there is damage.
B. Move your unit as close to the final location as
possible before removing the wooden skid.
• Contact True Technical Service for BTU
requirements.
REMOTE UNITS (This section applies to
remotes only!)
• No wiring necessary between cabinet and
condensing unit.
• Remote cabinets must be ordered as remote.
We do not recommend converting from a
standard self contained to remote system.
• All remote condensing units purchased from
True are 208/230 volts single phase.
• All remote cabinets must be hard wired.
• No castors available.
If you have any questions regarding this
section, please call True at 1-(800)-325-6152.
• All remote cabinets come standard using 404A
refrigerant.
• All remote units come standard with expansion
valve, liquid line solenoid, heated condensate
pan, and defrost timer when applicable.
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
LOCATING
Step 2
Removing
skid from
bottom of
cabinet.
A. Place packing material behind cabinet as a
cushion. Carefully lay the unit on its back to
remove skid.
When lifting unit remember to
leave the cabinet upright for 24 hours before
plugging into power source.
°
B. Remove skid by unscrewing all base rail anchor
brackets. Place skid to the side.
C. Carefully lift cabinet upright.
INSTALLATION OF LEGS AND CASTORS
Important Safeguard for installation of leg/castor (Images 1 & 2 demonstrate procedure)
Install the desired number of shims (in pairs as shown
in image 1), making sure the slots in the shim are in
contact with the castor mounting bolts.
Step 3
Leveling Castors
Four sets of shims have been provided in warranty
packet for leveling castored units positioned on uneven
floors. Shims must be positioned between cabinet and
castor mounting plate.
Tighten and secure the shims and castor(s). Remove 6”
block and check to determine if cabinet is level. Repeat
process until cabinet is level.
(See image 1 below).
Ensure that the drain hose or hoses are positioned in the
pan.
If the cabinet is not level prop up one end of the cabinet
between castors with a 6” block.
(See image 2)
NOTE:
Do not push block more than 5” under cabinet.
Loosen castor bolts with an adjustable wrench enough
to slide shims between the castor mounting plate and
cabinet bottom.
Left Shim
In Position
Top View
Leveling Shims
Snug Fit
Here
35°
F°
Castor
Mounting
Plate
Leveling Shims
Castor
Side View
6”
(Image 1.)
(Image 2.)
5
5
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
LEVELING
Step 4
D. Ensure that the drain hose or hoses are positioned in
the pan.
A. Set unit in its final location. Be sure there is
adequate ventilation in your room. Under extreme heat
conditions, (100°F+, 38°C+), you may want to install an
exhaust fan.
E. Free plug and cord from inside the lower rear of the
cooler (do not plug in).
F. The unit should be placed close enough to the
Warning
electrical supply so that extension cords are never used.
Warranty is void if ventilation is insufficient.
Warning
Compressor warranties are void if compressor
burns out due to low voltage. Power supply cord
ground should not be removed!
B. Proper leveling of your True cooler is critical to
operating success (for non-mobile models). Effective
condensate removal and door operation will be effected
by leveling.
C. The cooler should be leveled front to back and side
to side with a level.
ELECTRICAL INSTRUCTIONS
Step 5
True requires that a sole use circuit be dedicated for the
unit. Failure to do so voids warranty.
A. Before your new unit is connected to a power
supply, check the incoming voltage with a voltmeter.
If anything less than 100% of the rated voltage for
operation is noted, correct immediately.
WARNING
Compressor warranties are void if compressor
burns out due to low voltage.
B. All units are equipped with a 6 ft. (1.83 m) service
cord, and must be powered at proper operating voltage
at all times. Refer to cabinet data plate for this voltage.
WARNING
Power supply cord ground should not be
removed!
NOTE
To reference wiring diagram - Remove front
louvered grill, wiring diagram is positioned on the
inside cabinet wall.
6
6
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
CONDUCTORS AND CIRCUITS
Wire Gauge for 2% Voltage Drop in Supply Circuits
115 Volt
Amps
Distance In Feet To Center of Load
40 50 60 70 80
14 14 14 14
20
14
14
14
14
14
30
14
14
14
14
14
90
14
14
14
12
12
100
14
14
14
12
12
120
14
14
12
12
10
140
14
14
12
10
10
160
14
12
12
10
10
2
3
4
5
6
14
14
14
14
12
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
7
8
9
10
12
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
12
12
12
14
12
12
12
10
12
12
12
10
10
12
12
10
10
10
12
10
10
10
8
10
10
10
10
8
10
10
8
8
8
10
8
8
8
8
8
8
8
8
6
14
16
18
20
25
14
14
14
14
12
14
12
12
12
10
12
12
10
10
10
10
10
10
10
8
10
10
8
8
8
10
8
8
8
6
8
8
8
8
6
8
8
8
6
6
8
8
8
6
6
6
6
8
6
5
6
6
8
5
4
6
6
5
5
4
30
35
40
45
50
12
10
10
10
10
10
10
8
8
8
8
8
8
6
6
8
6
6
6
6
6
6
6
6
5
6
6
5
5
4
6
5
5
4
4
6
5
4
4
3
5
4
4
3
3
4
4
3
3
2
4
3
2
2
1
3
2
2
1
1
Wire Gauge for 2% Voltage Drop in Supply Circuits
230 Volts
Amps
Distance In Feet To Center of Load
20
14
14
14
14
14
30
14
14
14
14
14
40
14
14
14
14
14
50
14
14
14
14
14
60
14
14
14
14
14
70
14
14
14
14
14
80
14
14
14
14
14
90
14
14
14
14
14
100
14
14
14
14
12
120
14
14
14
12
12
140
14
14
12
12
12
160
14
12
12
12
10
5
6
7
8
9
10
12
14
16
18
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
12
12
14
14
12
12
12
14
12
12
12
10
12
12
12
10
10
12
12
10
10
10
12
10
10
10
8
10
10
10
8
10
10
8
8
8
8
20
25
30
35
40
14
14
14
14
14
14
14
12
12
12
14
12
12
10
10
12
12
10
10
10
10
10
10
10
8
10
10
10
8
10
10
8
8
8
10
10
8
8
6
10
8
8
8
6
8
8
6
6
6
8
6
6
6
5
8
6
6
5
5
8
50
60
70
80
90
100
12
12
10
10
10
10
10
10
10
8
8
8
10
8
8
8
6
8
6
6
6
6
6
6
6
6
6
5
5
6
6
6
5
5
4
6
6
5
5
4
4
6
6
5
4
4
3
6
5
4
4
3
3
5
4
4
3
3
2
4
4
2
2
1
1
4
3
2
2
1
1
6
7
7
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
STARTUP
Step 6
NOTE
If the cooler is disconnected or shut off, wait five
minutes before starting again.
A. The compressor is ready to operate. Plug in the
cooler.
B. Temperature control set at No. 4 position gives
refrigerators an approximate temperature of 35°F.
Allow unit to function several hours, completely cooling
cabinet before changing the control setting.
RECOMMENDATION
Before loading product we recommend you
run your True unit empty for two to three days.
This allows you to be sure electrical wiring and
installation are correct and no shipping damage
has occurred. Remember, our factory warranty
does not cover product loss!
C. Excessive tampering with the control could lead to
service difficulties. Should it ever become necessary to
replace temperature control, be sure it is ordered from
your True dealer or recommended service agent.
REPLACEMENT PARTS
D. Good air flow in your True unit is critical. Be careful
to load product so that it neither presses against the back
wall, nor comes within four inches of the evaporator
housing. Refrigerated air off the coil must circulate
down the back wall.
TRUE maintains a record of the cabinet serial
number for your cooler. If at any time during
the life of your cooler, a part is needed, you
may obtain this part by furnishing the model
number and serial number to the company from
whom you purchased the cooler. Call Toll-Free:
(800)-424-TRUE (Direct to Parts Department).
(800)-325-6152 (U.S.A. & Canada only) or call:
(636)-240-2400.
8
8
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following:
REQUIRED TOOLS:
• Phillips Screwdriver
• Stiff Bristle Brush
• Adjustable Wrench
• Vacuum Cleaner
Step 1
Disconnect power to unit.
Step 2
Image 1.
Remove the front grill by backing out four corner thumb
screws. (See image 3).
Step 3
Remove bolts anchoring compressor assembly to frame
rails and carefully slide out. (tube connections are
flexible)
Step 4
Clean off accumulated dirt from the condenser coil and
the fan with a stiff bristle brush. (See image 1).
Image 2.
Step 5
Lift cardboard cover above fan at plastic plugs and
carefully clean condenser coil and fan blades.
Step 6
After brushing condenser coil vacuum dirt from coil, and
35°
F°
interior floor. (See image 2)
Step 7
Replace cardboard cover. Carefully slide compressor
assembly back into position and replace bolts.
Step 8
Reinstall front grill assembly onto unit. Tighten all
screws.
Image 3.
Step 9
Connect unit to power and check to see if compressor is
running.
9
9
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
IMPORTANT WARRANTY INFORMATION
Condensers accumulate dirt and require cleaning every 30 days. Dirty
condensers result in compressor failure, product loss, and lost sales... which are
not covered by warranty.
If you keep the Condenser clean you will minimize your service expense and lower your
electrical costs. The Condenser requires scheduled cleaning every thirty days or as needed.
Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.
A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product
Loss, and Lost Sales.
Proper cleaning involves removing dust from the Condenser. By using a soft brush, or
vacuuming the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.
If you cannot remove the dirt adequately, please call your refrigeration service company.
The Condenser looks like a group of vertical fins. You need to be able to see through the
condenser for the unit to function at maximum capacity.
THE CLEANING OF THE CONDENSER IS NOT
COVERED BY THE WARRANTY!
Air
flow
HOW TO CLEAN THE CONDENSER:
1. Disconnect the electrical power to the unit.
2. Remove the louvered grill.
Condensing Unit
Condenser
3. Vacuum or brush the dirt, lint, or debris from the finned condenser coil.
4. If you have a significant dirt build up you can blow out the condenser with compressed air.
(CAUTION MUST BE USED to avoid eye injury. Eye protection is recommended.)
5. When finished be sure to replace the louvered grill. The grill protects the condenser.
6. Reconnect the electrical power to the unit.
If you have any questions, please call True Manufacturing at 636-240-2400 or 800-325-6152 and
ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to
5:30p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.
10
10
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
TEMPERATURE CONTROL ADJUSTMENT FOR
HIGH ALTITUDE ONLY!
TERMS:
__________ STEP 4 ___________
Cut-out - Temperature sensed
by the controller that shuts the
compressor off.
For high elevation installations, it
may be necessary to “warm-up” the
set points. To make the adjustment,
insert the appropriate tool in each
adjustment screw and turn 1/4 of a
revolution clockwise (to the right).
This procedure will adjust both
the cut-in and cut-out about 2°F
warmer.
Cut-in - Temperature sensed by the
controller that turns the compressor
on.
REQUIRED TOOLS
• Phillips Head Screwdriver
• 5/64” or 2 mm Allen Wrench
• T-7 Torx Wrench
__________ STEP 5 ___________
Make sure to reconnect the pink
wire to the proper spade
__________ STEP 1 ___________
terminal when reinstalling.
Unplug the cooler.
__________ STEP 2 ___________
Remove the screws that secure the
temperature control to the inset box
lower left side of the cabinet (when
facing the front of the cabinet).
Danfoss Temperature Control (High Altitude Adjustment Only!)
__________ STEP 3 ___________
Cut-out Adjustment Screw Allen (5/64”
or 2 mm) (clockwise for warmer)
Pull out gently from cabinet.
NOTE:
Cut-in Adjustment Screw Torx (T-7)
(clockwise for warmer)
Mechanical temperature
controllers are affected when
functioning at high altitude. The
cut-in and cut-out
temperatures will be colder than
when the controller
Compressor Connection (pink)
Compressor Connection (pink)
functions closer to sea level.
11
11
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
Stainless Steel Equipment Care and Cleaning
CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless
steel surfaces.
Stainless Steel Opponents
There are three basic things which can break down your stainless steel’s passivity layer and allow
corrosion to rear its ugly head.
1) Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be
abrasive to stainless steel’s surface.
2) Deposits left on your stainless steel can leave spots. You may have hard or soft water depending on
what part of the country you live in. Hard water can leave spots. Hard water that is heated can
leave deposits if left to sit too long. These deposits can cause the passive layer to break down and
rust your stainless steel. All deposits left from food prep or service should be removed as soon as
possible.
3) Chlorides are present in table salt, food, and water. Household and industrial cleaners are the worst
type of chlorides to use.
8 steps that can help prevent rust on stainless steel:
1. Using the correct cleaning tools
Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer
will not be harmed by soft cloths and plastic scouring pads. Step 2 tells you how to find the
polishing marks.
2. Cleaning along the polish lines
Polishing lines or “grain” are visible on some stainless steels. Always scrub parallel to visible lines on
some stainless steels. Use a plastic scouring pad or soft cloth when you cannot see the grain.
3. Use alkaline, alkaline chlorinated or non-chloride containing cleaners
While many traditional cleaners are loaded with chlorides, the industry is providing an ever
increasing choice of non-chloride cleaners. If you are not sure of your cleaner’s chloride content
contact your cleaner supplier. If they tell you that your present cleaner contains chlorides, ask if
they have an alternative. Avoid cleaners containing quaternary salts as they can attack stainless steel, causing
pitting and rusting.
4. Water Treatment
To reduce deposits, soften the hard water when possible. Installation of certain filters can remove
corrosive and distasteful elements. Salts in a properly maintained water softener can be to your
advantage. Contact a treatment specialist if you are not sure of the proper water treatment.
5. Maintaining the cleanliness of your food equipment
Use cleaners at recommended strength (alkaline, alkaline chlorinated or non-chloride). Avoid
build-up of hard stains by cleaning frequently. When boiling water with your stainless steel
equipment, the single most likely cause of damage is chlorides in the water. Heating any cleaners
containing chlorides will have the same damaging effects.
6. Rinse
When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe
standing cleaning agents and water as soon as possible. Allow the stainless steel equipment to air
dry. Oxygen helps maintain the passivity film on stainless steel.
7. Hydrochloric acid (muriatic acid) should never be used on stainless steel
8. Regularly restore/passivate stainless steel
12
12
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
Stainless Steel Equipment Care and Cleaning
Recommended cleaners for certain situations / environments of stainless steel
A) Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine
cleaning.
B) Arcal 20, Lac-O-Nu Ecoshine applied provides barrier film for fingerprints and smears.
C) Cameo, Talc, Zud First Impression is applied by rubbing in the direction of the polished lines for
stubborn stains and discoloring.
D) Easy-off and De-Grease It oven aid are excellent for removals on all finishes for grease-fatty acids,
blood and burnt-on foods.
E) Any good commercial detergent can be applied with a sponge or cloth to remove grease and oil.
F) Benefit, Super Sheen, Sheila Shine are good for restoration / passivation.
NOTE:
The use of stainless steel cleaners or other such solvents is not
recommended on plastic parts. Warm soap and water will suffice.
13
13
Download from Www.Somanuals.com. All Manuals Search And Download.
TRUE REFRIGERATIONTM
MADE IN
U.S.A.
WARRANTY INFORMATION (U.S.A & CANADA ONLY!)
SINCE 1945
ONE YEAR PARTS & LABOR WARRANTY
TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship,
under normal and proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with the instruction packet supplied
with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of one (1) year from the date of original installation or 15 months after shipment date
from TRUE, whichever occurs first.
Any part covered under this warranty that are determined by TRUE to have been defective within one (1) year of original installation or fifteen (15) months after
shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies. The labor
warranty shall include standard straight time labor charges only and reasonable travel time, as determined by TRUE.
ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY
In addition to the one (1) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed compressor to be free from defects in both
material and workmanship under normal and proper use and maintenance service for a period of four (4) additional years from the date of original installation but not to
exceed five (5) years and three (3) months after shipment from the manufacturer.
Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a compressor
or compressor parts of similar design and capacity.
The four (4) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply to any other
parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly or
any other electrical component, etcetera.
404A/134A COMPRESSOR WARRANTY
The four year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:
1. This system contains R404A or R134A refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. If long exposure
to the ambient conditions occur, the lubricant must be removed and replaced with new. For oil amounts and specifications please call True technical service department
(800-325-6152). Failure to comply with recommended lubricant specification will void the compressor warranty.
2. Drier replacement is very important and must be changed when a system is opened for servicing. A drier using XH-7 desiccant or an exact replacement solid
core drier must be used. The new drier must also be the same capacity as the drier being replaced.
3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.
WARRANTY CLAIMS
All claims for labor or parts must be made directly through TRUE. All claims should include: model number of the unit, the serial number of the cabinet, proof of
purchase, date of installation, and all pertinent information supporting the existence of the alleged defect.
In case of warranty compressor, the compressor model tag must be returned to TRUE along with above listed information.
Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has occurred.
WHAT IS NOT COVERED BY THIS WARRANTY
TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither
assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.
NO CONSEQUENTIAL DAMAGES. TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON
ACCOUNT OF REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH
ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPROPER USAGE. TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING
FROM IMPROPER USAGE OR INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED
WITH THE UNIT.
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TRUE is not
responsible for the repair or replacement of any parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse,
accident, damage during transit or installation, fire, flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS. TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS
RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE ARE NO OTHER WARRANTIES, EXPRESSED,
IMPLIED OR STATUTORY, EXCEPT THE ONE (1) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY
AS DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF.
OUTSIDE U.S.: This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United States.
REMOTE CONDENSERS: True warrants the original purchaser of the remote cabinet one year parts and labor coverage for all cabinet parts thereof to be free
from defects in material or workmanship, under normal and proper use and maintenance service, as specified by True. This warranty is limited to the cabinet only. True
assumes no liability for remote condensing units.
14
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|