SPS-1872-CC (Conversion Center™)
SPS-1872-DPS (Dual PointSystem™)
SPS-1872-PS (PointSystem™)
User’s Guide
SPS-1872-xx
External Power Supply
18-60 VDC and 24-30 VRMS
SPS-1872-SA (Stand-Alone)
SPS-1872-SA
SPS-1872-CC
SPS-1872-DPS
SPS-1872-PS
The Transition Networks SPS-1872-xx external power supply provides a wide range
of input power (18-60 VDC and 24-30 VRMS) to accommodate most industrial,
telecom, and commercial applications. The SPS-1872-xx can deliver 12 watts of
power, enough to power all Transition Networks stand-alone media converters as
well as the single-slot (p/n CPSMC0100-20x) and the dual-slot (p/n CPSMC0200-2xx)
chassis.
The 18-60 VDC input allows for the installation of the SPS-1872-xx external power
supply in all popular telecom, commercial, and industrial applications. The 24-30
VRMS input allows for installation of the SPS-1872-xx in remaining industrial
applications as well as HVAC and building control environments.
The 'piggy-back' feature of the SPS-1872-CC, SPS-1872-PS, and SPS-1872-DPS
allows it to physically attach to the media converter chassis and eliminate the power
cable between the power supply and the media converter.
Installation . . . . . . . . . . . . . . . . . .2
Maintenance . . . . . . . . . . . . . . . .7
Technical Specifications . . . . . . . .8
Compliance Information . . . . . . .10
Contact Us . . . . . . . . . . . . . . . . .11
Download from Www.Somanuals.com. All Manuals Search And Download.
SPS1872-xx
Installation -- Continued
Installation -- Continued
SPS-1872-CC (Conversion Center™)
SPS-1872-DPS (Dual PointSystem™)
1. Remove the left-rear and right-rear screws from the Conversion Center™
1. Remove the left-rear and right-rear screws from the Dual PointSystem™
media converter.
media converter.
2. Connect the barrel connector on the SPS-1872-CC to the power port of
the media converter The flange of the SPS-1872-CC should slide over
the rear of the media converter as the two devices are connected. The
screw holes on the left and right sides should align.
2. Connect the barrel connector on the SPS-1872-DPS to the power port of
the media converter. The flange of the SPS-1872-DPS should slide over
the rear of the media converter as the two devices are connected. The
screw holes on the left and right sides should align.
3. Secure the two devices together by replacing the two screws on either
side of the SPS-1872-CC.
3. Secure the two devices together by replacing the two screws on either
side of the SPS-1872-DPS.
TN Conversion Center
media converter
TN Dual PointSystem
media converter
SPS-1872-CC
SPS-1872-DPS
SPS-1872-PS (PointSystem™)
1. Remove the left-rear and right-rear screws from the PointSystem™ media
converter.
2. Connect the barrel connector on the SPS-1872-PS to the power port of
the media converter. The flange of the SPS-1872-PS should slide over the
rear of the media converter as the two devices are connected. The screw
holes on the left and right sides should align.
3. Secure the two devices together by replacing the two screws on either
side of the SPS-1872-PS.
TN PointSystem
media converter
SPS-1872-PS
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600
5
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SPS-1872-xx
Installation -- Continued
Maintenance
Supplying Power to the SPS-1872-xx
Replacing the Fuse
CAUTION: The power source MUST BE TURNED OFF when connecting it to
the SPS-1872-xx external power supply. Failure to observe this caution could
result in damage to, and subsequent failure of, the SPS-1872-xx and any attached
device.
CAUTION: The external power source MUST BE POWERED OFF when
replacing the fuse to the SPS-1872-xx external power supply. Failure to observe
this caution could result in damage to, and subsequent failure of, the SPS-1872-
xx and any attached device.
To supply power to the SPS-1872-xx:
NOTE: Replace the fuse only with one of the same size and rating.
1. Ensure that external power source is truned OFF.
To replace the fuse in the SPS-1872-xx external power supply:
1. Ensure that the external power source is turned OFF.
2. Connect the positive (+) terminal of the power source to the positive
terminal on the SPS-1872-xx (marked with a “3”). Turn the terminal
screw clockwise to secure it.
2. Remove and retain the four (4) screws that secure the cover to the SPS-
1872-xx external power supply.
3. Connect the negative (-) terminal of the power source to the negative
terminal on the SPS-1872-xx (marked with a “2”). Turn the terminal
screw clockwise to secure.
3. Carefully lift the cover from the SPS-1872-xx.
4. Locate the fuse on the SPS-1872-xx (see the picture below).
4. Connect the ground terminal of the power source to the ground terminal
on the SPS-1872-xx (marked with a “1”). Turn the terminal screw
clockwise to secure.
5. Power on the external power source.
WARNING: The SPS1872 must be attached to a limited current circuit with a
non-hazardous energy level of less than 240VA and be located in a restricted
access area. Failure to observe this warning could result in an electrical shock.
5. Carefully remove the fuse the from the fuse holder.
6. Install a same size and rating replacement fuse in the fuse holder.
7. Carefully slide the cover onto the SPS-1872-xx.
1
2
3
INPUT
POWER:
SPS-1872-xx
1
2
3
8. Replace the four (4) retained screws that secure the cover to the SPS-
1872-xx.
___
___
___
-
+
9. Power on the external power source.
GND
-
+
External Power Source
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600
7
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPS1872-xx
Technical Specifications
Technical Specifications -- Continued
Input:
For use with Transition Networks Model SPS-1872-xx or equivalent.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
Input Voltage
18 - 60 VDC, 24 - 30 VRMS
Isolation Voltage
(Dielectric withstand) Meets IEC 950 for one minute
1500 VAC: Output/Input
Compliance
UL listed EN60950; FCC & CISPR class A; CE Mark
1500 VAC: Input/Safety GND
1500 VAC: Output/Case
Dimensions
(length x width x height)
SPS-1872-SA - 3.875 x 3.125 x 1.0 in (98 x 79 x 25 mm)
SPS-1872-CC - 4.625 x 3.125 x 1.062 in (117 x 79 x 27 mm)
SPS-1872-PS - 4.625 x 3.375 x 1.062 in (117 x 86 x 27 mm)
SPS-1872-DPS - 4.625 x 3.375 x 1.75 in (117 x 86 x 45 mm)
Output:
Output Voltage
Output Current
Load Regulation
Over Load Protection
12.6 VDC
Power Distribution
Power Consumption
Efficiency
12.6 VDC at 1.0 A maximum
6 W maximum @ 18 VDC input, 12.6 W output
70 % (typical)
1.0 A
5% at 10% load to full-rated load
(OLP) When the average power rating exceeds 125%-
150% of the maximum power, the output voltage is
reduced to a safe dissipation level. This action protects
against output short circuit.
Noise and Ripple
MTBF
40 mV peak-to-peak
>290,000 hours Belcore with typical load at 50°C
ambient temperature (calculated according to Belcore).
>834,000 hours with typical load at 50°C ambient
temperature (calculated according to MIL-HDBK-217F).
No Load Operation
Transient Protection
No damage to power supply when operating at no load.
No voltage spike at power-on, power-off, or power
failure.
Environment
Warranty
Tmra*:
0 to 50°C (32 to 122° F )
Storage Temp: -20 to 85°C
Humidity:
Altitude:
5 to 95%, non condensing
0 to 10,000 feet
(*Manufacturer’s rated ambient temperature)
Lifetime
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600
9
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SPS-1872-xx
Contact Us
Technical Support
Compliance Information
UL Listed
Technical support is available 24 hours a day.
C-UL Listed (Canada)
CISPR/EN55022 Class A + EN55024
FCC Regulations
United States:
International:
1-800-260-1312
00-1-952-941-7600
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference. In which case, the user will be required to correct the
interference at the user’s own expense.
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb
dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
telephone:
toll free:
fax:
952-941-7600
800-526-9267
952-941-2322
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de
créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les
measures spécifiques appropriées.
Declaration of Conformity
In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will
accept post usage returns of this product for proper disposal. The contact
information for this activity can be found in the 'Contact Us' portion of this
document.
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
SPS-1872-xx External Power Supply
SPS-1872-SA, SPS-1872-CC, SPS-1872-PS, SPS-1872-DPS
EMC Directive 89/336/EEC
Model:
Part Number:
Regulation:
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Purpose: To declare that the SPS-1872-xx to which this declaration refers is in
conformity with the following standards.
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 subpart B;
EN55024:1998; UL Listed
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
May 23, 2006_____
Stephen Anderson, Vice-President of Engineering
Date
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600
11
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2003, 2005 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means – graphic, electronic, or mechanical – without written permission from Transition
Networks.
Printed in the U.S.A.