User’s Guide
CGETF10xx-10x
Slide-in-Module Media Converter
• Gigabit Ethernet
• Copper to Fiber
• 1000Base-T to 1000Base-SX/LX
Transition Networks CGETF10xx-10x Gigabit
Ethernet media converter connects 1000Base-T
shielded or unshielded twisted-pair copper cable to
1000Base-SX or 1000Base-LX, fiber-optic cable.
The CGETF10xx-10x is also designed to be
installed in the Transition Networks PointSystem™
chassis.
Part Number
Port One - Copper Port Two - Duplex Fiber-Optic
CGETF1013-105 RJ-45 1000Base-T
SC, 1000Base-SX, 850 nm multimode
300 m (984 ft)* (62.5/125 µm cable)
500 m (1,640 ft)* (50/125 µm cable)
100 m (328 ft)*
CGETF1014-105 RJ-45 1000Base-T
SC, 1000Base-LX, 1310 nm single mode
10 km (6.2 miles)*
100 m (328 ft)*
CGETF1015-105 RJ-45 1000Base-T
SC, 1000Base-LX, 1310 nm single mode
25 km (15.5 miles)*
100 m (328 ft)*
CGETF1017-105 RJ-45 1000Base-T
SC, 1000Base-LX, 1550 nm single mode
65 km (40.4 miles)*
100 m (328 ft)*
CGETF1018-105 RJ-45 1000Base-T
MT-RJ, 1000Base-SX, 850 nm multimode
300 m (984 ft)* (62.5/125 µm cable)
500 m (1,640 ft)* (50/125 µm cable)
100 m (328 ft)*
CGETF1024-105 RJ-45 1000Base-T
SC, 1000Base-SX, 1300 nm extended
multimode, 2 km (1.2 miles)*
100 m (328 ft)*
Note: 62.5/125 µm (fiber only)
CGETF1035-105 RJ-45 1000Base-T
SC, 1000Base-LX, 1550 nm single mode
125 km (77.5 miles)*
100 m (328 ft)*
CGETF1039-105 RJ-45 1000Base-T
LC, 1000Base-SX, 850 nm multimode
300 m (984 ft)* (62.5/125 µm cable)
500 m (1,640 ft)* (50/125 µm cable)
100 m (328 ft)*
*Typical maximum cable distance. Actual
distance is dependent upon the physical
characteristics of the network installation.
Installation . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . .5
Cable Specifications . . . . . . . . .8
Technical Specifications . . . . .9
Troubleshooting . . . . . . . . . . .10
Contact Us . . . . . . . . . . . . . . .11
Compliance Information . . . .12
NOTE: The stand-alone version of the media
converter is SGETF10xx-10x. For more
information, see the SGETF10xx-10x user’s
Download from Www.Somanuals.com. All Manuals Search And Download.
CGETF10xx-10x
Installation -- Continued
Install the slide-in-module
Installation -- Continued
Install the copper cable
CAUTION: Slots in the PointSystem™ chassis without a slide-in-module
installed MUST have a protective plate covering the empty slot for Class A
compliance.
1. Locate or build 1000Base-T compliant copper cables with male, RJ-45
connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the CGETF10xx-10x media converter.
To install the CGETF10xx-10x media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ chassis.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device (switch, workstation, etc.).
2. Carefully slide the slide-in-module into the installation slot, aligning the
module with the installation guides.
3. Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the panel fastener screw (attached to the slide-in-
module) clockwise to secure the slide-in-module to the chassis front.
RJ-45 port
on the media
converter
RJ-45 port
on the other device
(switch, work station, etc.)
PWR
TX PWR
RX LNK
PWR
PWR
LA
L
L
LA
LKS
LKM
SPD
FRX
CRX
PWR
FLNK
CLNK
LNK
LNK
RXF
RXC
RXF
RXC
COL
COL
R
E
S
E
T
TX
Link Alert
Link Alert
E
D
E
D
TX
PWR
LKC
LKF
RXF
RXC
RX
TX
RX
0
50½
0
50½
RX
Operation
CPSMM120
CECF100
CETCF100
CFMFF100
CFETF100
The slide-in-module is powered through the
Transition Networks PointSystem™ chassis.
Status LEDs
Panel Fastener Screw
Use the status LEDs to monitor the CGETF10xx-10x media
converter operation in the network.
Install the Fiber Cable
PWR
LKF
PWR (Power)
ON = Connection to external AC
power.
RXF
RXC
1. Locate or build 1000Base-SX/LX compliant fiber cable with male, two-
stranded TX to RX connectors installed at both ends.
LKC
LKF (Fiber link)
ON = Fiber link connection.
ON = Copper link connection.
TX
2. Connect the fiber cables to the CGETF10xx-10x media converter as
described:
LKC (Copper link)
RXF (Fiber receive) Flashing = Reception of data on
•
•
Connect the male TX cable connector to the female TX port.
Connect the male RX cable connector to the female RX port.
the fiber link.
RXC (Copper receive) Flashing = Reception of data on
3. Connect the fiber cables to the other device (another media converter,
hub, etc.) as described:
the copper link.
RX
•
•
Connect the male TX cable connector to the female RX port.
Connect the male RX cable connector to the female TX port.
Connect the fiber cable
to the other device
(media converter,
Connect the fiber cable
to the media converter
as shown.
hub, etc.) as shown
RX
TX
RX
TX
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CGETF10xx-10x
Operation - Continued
Operation
Link Pass-Through
Pause
The Link Pass-Through feature allows the media converter to monitor both the
fiber and copper RX (receive) ports for loss of signal. In the event of a loss of
an RX signal (1), the media converter will automatically disable the TX
(transmit) signal (2), thus, “passing through” the link loss (3). The far-end
device is automatically notified of the link loss (4), which prevents the loss of
valuable data unknowingly transmitted over an invalid link.
The pause feature can improve network performance by allowing one end of
the link to signal the other to discontinue frame transmission for a set period
of time to relieve buffer congestion.
In Hardware mode, the pause feature can be set to
•
•
Disable (i.e., no pause)
Enable (i.e., symmetrical pause)
In Software mode, the pause feature can be set to one of four settings:
media converter A
media converter B
disables the fiber TX link
loses the fiber RX link
•
•
•
•
Disable (i.e., no pause)
Symmetrical pause
Asymmetric TX (transmit) pause
Asymmetric RX (receive) pause
2
3
Near-End
Device
Media
Converter A
Media
Converter B
Far-End
Device
4
1
Enable the pause feature if it is present on ALL network devices attached to
the media converter(s). Otherwise, disable the pause feature.
original fault
on the copper link
media converter B
disables the copper link
Full-Duplex network
SNMP
In a full-duplex network, maximum cable lengths are determined by the type
of cables that are used. See pages 1 and 2 for the cable specifications for the
different CGETF10xx-10x models.
Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:
•
•
•
Copper and fiber link/receive status
Hardware switch settings
Receive error count
The 512-Bit Rule does not apply in a full-duplex network.
Half-Duplex network (512-Bit Rule)
Also, use SNMP to enter network commands that:
In a half-duplex network, the maximum cable lengths are determined by the
round trip delay limitations of each Fast Ethernet collision domain. (A
collision domain is the longest path between any two terminal devices, e.g. a
terminal, switch or router.)
•
•
•
•
•
•
•
Enable/disable full-duplex and half-duplex advertisement
Enable/disable Link Pass-Through
Enable/disable Auto-Negotiation
Symmetric pause
Asymmetric TX (transmit) pause
Asymmetric RX (receive) pause
Disable pause
The 512-Bit Rule determines the maximum length of cable permitted by
calculating the round-trip delay in bit-times (BT) of a particular collision
domain. If the result is less than or equal to 512 BT, the path is good.
See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.
For more information on the 512-Bit Rule, see the white paper titled
“Collision Domains” on the Transition Networks website at:
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CGETF10xx-10x
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Cable Specifications -- Continued
Fiber Cable - Continued
CGETF1039-105
850 nm multimode
Fiber Cable
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Link Budget:
min: -9.0 dBm
min: -17.0 dBm
8.0 dB
max: -4.0 dBm
max: -17.0 dBm
Bit Error Rate:
<10-9
9 µm
Single mode fiber (recommended):
Multimode fiber (recommended):
Multimode fiber (optional):
62.5/125 µm
100/140, 85/140, 50/125 µm
Copper Cable (Category 5 -- minimum requirement)
• Gauge = 24 to 22 AWG; Attenuation = 22.0 dB /100m @ 100 MHz
• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network.
• Use only dedicated wire pairs for the active pins; e.g., blue/white & white/blue,
orange/white & white/orange, etc.
CGETF1013-105
850 nm multimode
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Link Budget:
min: -10.0 dBm
min: -17.0 dBm
7.0 dB
max: -4.0 dBm
max: 0.0 dBm
CGETF1014-105
1310 nm single mode
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: -13.0 dBm
min: -20.0 dBm
7.0 dB
max: -3.0 dBm
max: -3.0 dBm
• Do not use flat or silver satin wire.
CGETF1015-105
1310 nm single mode
Technical Specifications
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: -5.0 dBm
min: -20.0 dBm
15.0 dB
max: -0.0 dBm
max: -3.0 dBm
For Transition Networks’ Model CGETF10xx-10x or equivalent
Standards:
IEEE 802.3ab™, IEEE 802.3 2000
1000 Mbs/300 nsec
CGETF1017-105
1550 nm single mode
Data Rate / Delay:
Dimensions:
Weight:
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: -3.0 dBm
min: -23.0 dBm
20.0 dB
max: +2.0 dBm
max: -3.0 dBm
3.4" x 0.87" x 4.8" (86mm x 22mm x 122mm)
3 oz. (91 g) approximate
CGETF1018-105
850 nm multimode
min: -10.0 dBm
min: -17.0 dBm
7.0 dB
Power Consumption:
Packet Size:
MTBF
5.4W, 450mA @ 12VDC
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Link Budget:
max: -4.0 dBm
max: 0.0 dBm
10 Kbytes (maximum)
381,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,344,000 hours (Bellcore7 V5.0)
CGETF1024-105
1300 nm extended multimode
Operating Temp:
Storage Temp:
Humidity:
Tmar* 0°C to 50°C (32°F to 122°F)*
-15°C to 65°C (5°F to 149°F)
10% to 90%, non condensing
0 to 10,000 feet
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: -10.0 dBm
min: -17.0 dBm
7.0 dB
max: -3.0 dBm
max: -3.0 dBm
Altitude:
CGETF1029-105
CGETF1029-106
1310nm TX / 1550nm RX single mode
1550nm TX / 1310nm RX single mode
Warranty:
Lifetime
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: -8.0 dBm
min: -21.0 dBm
13.0 dB
max: -3.0 dBm
max: -3.0 dBm
*Manufacturer’s rated ambient temperature. “Tmra” range for this slide-in-module depends
on the physical characteristics and the installation configuration of the Transition Networks
PointSystem™ chassis in which this slide-in-module will be installed.
CGETF1029-107
CGETF1029-108
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
1310nm TX / 1550nm RX single mode
1550nm TX / 1310nm RX single mode
The information contained in this user’s guide is subject to change. For the most up-to-date
information on the CGETF10xx-10x media converter, view the user’s guide on-line at:
min: -3.0 dBm
min: -23.0 dBm
20.0 dB
max: +2.0 dBm
max: -8.0 dBm
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or
view directly with optical instruments.
CGETF1035-105
1550 nm single mode
CAUTION: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget:
min: 0.0 dBm
min: -27.0 dBm
27.0 dB
max: +5.0 dBm
max: -3.0 dBm
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-
825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CGETF10xx-10x
Troubleshooting
Contact Us
If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:
Technical support
Technical support is available 24-hours a day
US and Canada:
International:
1.
Is the PWR (power) LED illuminated?
NO
1-800-260-1312
00-1-952-941-7600
•
•
Is the media converter inserted properly into the chassis?
Is the power cord properly installed in the chassis and at the external
power source and does the external power source provide power?
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Transition now
Chat live via the Web with Transition Networks Technical Support.
•
YES
•
Proceed to step 2.
Web-based seminars
Transition Networks provides seminars via live web-based training.
2.
3.
Is the LKC (copper link) LED illuminated?
NO
•
Check the twisted-pair copper cables for proper connection.
E-Mail
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Ask a question anytime by sending an e-mail to our technical support staff.
YES
•
Proceed to step 3.
Is the LKF (fiber link) LED illuminated?
Address
NO
•
•
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, USA
Check the fiber cables for proper connection.
Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.
If the converter is connected to another xGETF10xx-10x via fiber,
make sure that the Auto-Negotiation (DIP switch 4) is disabled (UP)
in hardware mode, or disabled via software in software mode.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
telephone:
toll free:
fax:
952-941-7600
800-526-9267
952-941-2322
•
•
Declaration of Conformity
YES
•
Proceed to step 4.
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
CGETF10xx-10x Series Media Converters
CGETF1013-105, CGETF1014-105, CGETF1015-105,
CGETF1017-105, CGETF1018-105, CGETF1024-105,
CGETF1029-105, CGETF1029-106,CGETF1035-105,
CGETF1029-107, CGETF1029-108, CGETF1039-105
4.
Is the RXC (copper receive) LED flashing?
Model:
Part Number(s):
NO
•
•
If there is no activity on the 1000Base-T port, proceed to step 5.
If there is activity on the 1000Base-T port, disconnect and reconnect
the twisted-pair copper cable to restart the initialization process.
Restart the workstation to restart the initialization process.
•
Regulation:
EMC Directive 89/336/EEC
•
YES
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Purpose: To declare that the CGETF10xx-10x to which this declaration refers is in
conformity with the following standards.
CISPR 22:1993; EN 55022:1998 Class A; FCC Part 15 Subpart B; EN55024:1998;
21CFR subpart J; EN 61000-2-3:1995; EN61000-3-3:1995;
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
Proceed to step 5.
5.
Is the RXF (fiber receive) LED flashing?
NO
•
•
If there is no activity on the 1000Base-SX/LX port, continue below
If there is activity on the 1000Base-SX/LX port, disconnect and
reconnect the fiber cable to restart the initialization process.
Restart the workstation to restart the initialization process.
July 15, 2005____
Stephen Anderson, Vice-President of Engineering
Date
•
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Compliance Information
CISPR22/EN55022 Class A + EN55024
CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb
dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer
des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures
spécifiques appropriées.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright restrictions
© 2003-2005 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means - graphic, electronic or mechanical - without written permission from Transition
Networks.
Printed in the U.S.A.
33261.J
Download from Www.Somanuals.com. All Manuals Search And Download.
|