Toro Sprinkler INF34 User Manual

INFINITY Series Sprinkler with SMART ACCESS  
Installation and Service Guide  
Toro’s new INFINITY Series sprinklers with SMART ACCESS™ are designed  
specifically for Golf applications and extend and enhance Toro’s industry leading  
line of Golf sprinklers. Manufactured from durable, high-strength engineering  
plastic and stainless-steel components, the INFINITY Series sprinklers  
incorporate many innovative and time-proven features for lasting, maintenance-  
free operation.  
Six base models are available:  
INF34 - 1” (25 mm) ACME inlet, full circle, dual trajectory  
INF54 - 1.5” (40 mm) ACME inlet, full circle, dual trajectory  
INF35 - 1” ACME inlet, full/part circle, dual trajectory  
INF55 - 1.5” ACME inlet, full/part circle, dual trajectory  
INF35-6 - 1” ACME inlet, full/part circle, 24 position TruJectory  
INF55-6 - 1.5” ACME inlet, full/part circle, 24 position TruJectory  
e SMART ACCESS feature adds several significant capabilities that allow maintenance crews to access most internal  
components without having to dig or turn off the water.  
Prior to installing the sprinkler, please read this Installation and Service Guide for proper installation and servicing procedures.  
Observe all Warnings and Cautions when installing and operating this equipment.  
Product Features  
Top accessibility of the pilot valve, GDC intelligence  
module, wire splices, and all future enhancements. No  
excavation required to access any internal components.  
• Similar physical dimensions as Toro’s original sprinkler  
bodies for easy replacement.  
• Removeable marker is customizable for yardage markers,  
station number, golf course branding, and/or other  
customer desired information.  
• Pilot valve is removeable while system is under pressure.  
• Compartments provide space for current features and  
future enhancements.  
Installation  
Toro Swing Joints  
Toro recommends using Toro Swing Joints for INFINITY Series sprinklers.  
On sites where the possibility of heavy equipment rolling over the  
sprinkler exists, the swing joint will flex preventing damage to the lateral  
or main lines.  
On a new installation in raw ground where the sprinklers are to be  
initially installed above the finished grade and lowered when the turf  
is established, the swing joint allows sprinkler repositioning without  
changing risers.  
Note the correct and incorrect  
swing-joint installation method.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking the Sprinkler  
1
3
2
Lift the cover.  
Remove accessory kit.  
Remove the retaining screw.  
Waterproof Wire Splices  
CAUTION: All wire splices and field connections must be waterproofed to prevent short circuit to ground and  
subsequent controller damage.  
!
is type of waterproofed wire splice is for use with solid and/or stranded wire connections.  
1 - 3 #12  
1 - 4 #14  
1 #10 w/ 1-4 #18  
1 #14 w/ 1-4 #18  
2 - 5 #16  
1 #12 w/ 1-4 #18  
3 #14 w/ 1 or 2 #18  
2 - 5 #18  
2 #12 w/ 1 or 2 #18  
Steps  
1. Strip wires (12-16 gauge) 7/16” (11 mm)  
2. Pre-twisting is unneccessary. Hold stripped wires together with ends even (Figure 1). Lead stranded wires slightly.  
Align any frayed strands or conductors.  
3. Firmly push wire into connector and screw connector clockwise onto wire until tight (Figure 1).  
4. Insert the splice to the bottom of the sealant filled tube (Figure 2).  
5. Position wires into wire channels (Figure 3). Wipe away any sealant around opening and conductors.  
6. Close lid ensuring latch is secured (Figure 4).  
Figure 1  
Figure 2  
Figure 4  
Figure 3  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sprinkler Wiring Connections  
Connecting Communication Cable to the INFINITY Series with GDC Module  
e GDC system provides a coded DC signal over a polarity sensitive color coded communication cable that requires correct  
connections to ensure proper operation. e GDC system also employs a daisy chain communication network where all  
sprinklers, except the last one on a wire run, will have one cable coming in from the Gateway or closer sprinkler and another  
going out to the next sprinkler.  
1. If using jacketed cable, remove ~20” (508  
Figure 1  
Figure 2  
mm) of shielding from communication  
cable(s).  
2. Route wires through the access grommet in  
the bottom of the sprinkler compartment.  
Provide a service loop below the sprinkler  
to allow for height adjustment and future  
servicing. (See Figure 1.)  
access  
grommet  
3. Pull cable(s) out the top of the sprinkler  
approximately 6˝ (152 mm). (See Figure 2.)  
4. Strip 12-16 gauge wires 7/16˝ (11 mm) of  
service loops  
insulation. (See Figure 2.)  
5. Connect the white cable wire(s) and the white  
GDC module wire with a wire nut and install  
into a waterproof grease cap (both provided).  
(See Figure 3.)  
Figure 3  
6. Repeat for the black wire(s). (See Figure 3.)  
wire nut  
7. Fold and tuck the cable connections into the  
compartment pocket.  
spare screw  
8. Record GDC module address and reference to  
site location. Remove the 2 additional address  
labels from the accessory kit. Affix one to the  
cover for temporary future reference and the  
other to the location identification form for  
entry at the central controller.  
grease cap  
address label  
9. Replace cover and install the three (3) cover  
screws (from accessory kit). Tighten to 25  
in/lb. (34,6 kilogram force meters) max or  
medium torque and low speed setting on a  
battery-powered screw-driver.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting Control Wires to the INFINITY Series with Satellite  
e field satellite controllers provide a 24 VAC  
signal to the sprinklers typically using individual  
Figure 1  
Figure 2  
wires. Connections to the sprinkler solenoid in  
these systems are not polarity sensitive and do  
not require specific wire connections. Typically  
the “common” wire from the controller is daisy-  
chained to multiple sprinklers with one wire  
access  
grommet  
service loops  
coming in from the satellite or closer sprinkler  
and the other going on to the next sprinkler. e  
station output “hot” wire typically connects to a  
single sprinkler but can also be daisy-chained to  
multiple sprinklers depending upon the control  
system capabilities.  
1. Route all wire(s) through the access grommet  
in the bottom of the sprinkler compartment  
providing a service loop below the sprinkler  
to allow for height adjustment and future  
servicing. (See Figure 1.)  
Figure 3  
wire nut  
2. Pull all wire(s) out the top of the sprinkler  
approximately 6˝ (152 mm). (See Figure 2.)  
3. Remove 7/16˝ (11 mm) of the insulation from  
all of the control wires. (See Figure 2.)  
grease cap  
4. Connect the “common” wire(s) to one of the  
solenoid wires with a wire nut and install into  
a waterproof grease cap (both provided).  
(See Figure 3.)  
5. Repeat for the station output “hot” wire(s).  
(See Figure 3.)  
6. Fold and tuck the wire connections into the  
compartment pocket.  
7. Replace cover and install the three (3) cover  
screws (from accessory kit). Tighten to 25 in/  
lb. (34,6 kilogram force meters) max or  
medium torque setting on a battery-powered drill.  
Final Adjustments  
Adjust the swing joint to bring the top of the sprinkler  
flush to grade. Back fill with clean porous material that  
promotes drainage. Tamp the soil around the sprinkler to  
compact the soil and prevent settling.  
service loops  
sand  
Toro swing joint  
mainline/lateral  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1: Recommended System Fill Rate  
Pipe Size  
inch  
1/2  
Flow  
GPM  
Velocity  
ft/sec  
1.60  
Pipe Size  
Flow  
GPM  
Velocity  
ft/sec  
1.86  
cm  
1.3  
1.9  
2.5  
3.1  
3.8  
5.0  
6.4  
LPM  
7.6  
m/sec  
0.49  
0.59  
0.46  
0.57  
0.43  
0.55  
0.56  
inch  
3
cm  
LPM  
170.3  
283.9  
567.8  
946.3  
1703.0  
1893.0  
m/sec  
0.57  
0.57  
0.53  
0.52  
0.60  
0.47  
2
7.6  
45  
3/4  
3
11.4  
18.9  
37.9  
37.9  
75.7  
113.6  
1.92  
4
10.1  
15.2  
20.2  
25.4  
30.5  
75  
1.87  
1
5
1.50  
6
150  
250  
450  
500  
1.73  
1-1/4  
1-1/2  
2
10  
10  
20  
30  
1.86  
8
1.70  
1.41  
10  
12  
1.97  
1.80  
1.55  
2-1/2  
1.84  
On - Off - Auto  
For normal operation, the Selector should be set to AUTO.  
ON  
Sprinkler will operate immediately.  
Sprinkler will not operate even when solenoid is activated.  
Normal operation. Sprinkler will operate when solenoid is activated  
according to the irrigation schedule.  
1
OFF  
AUTO  
Turn Selector to  
appropriate setting.  
Changing the Sprinkler’s Pressure Setting  
e sprinkler pilot valve can be set to four different pressure settings: 50, 65, 80, or 100 psi (3,5, 4,6, 5,6, or 7,0, kg/cm2  
respectively). e sprinkler pilot valve pressure is preset to the customer’s specifications.  
To change the setting:  
1.  
2.  
3.  
Loosen adjustment knob.  
Move knob to desired pressure setting.  
Tighten adjustment knob.  
To Remove Pilot Valve Assembly, follow steps on page 9.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service  
e INFINITY Series sprinklers are designed to provide the user trouble-free operation for many years without scheduled  
maintenance. If it becomes necessary to disassemble the sprinkler to correct a malfunction or replace a component, all internal  
parts of the sprinkler can be accessed from the top. Some special tools are required for disassembly and/or maintenance of the  
sprinkler and are available from your Toro dealer.  
To Remove the Lid  
1
2
Remove the top three (3) screws.  
Lift the cover.  
To Remove the Marker  
Every Toro INFINITY Series Sprinkler comes with a removable identification “marker”. is marker can be customized with  
yardage numbers, company logos, and more. Contact your Toro distributor for information regarding markings.  
1
2
Push the three marker tabs inward.  
Separate from cover.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Service the GDC Module  
e GDC module has wires running directly to the solenoid. Replacement requires cutting and splicing wires.  
Use water-proof wire splices to make all connections (see page 3).  
3
1
2
Cut black and white Control wires.  
Slide out Module.  
Cut red and black Solenoid wires.  
Strip 7/16” (11 mm) wire from  
Solenoid and Control wire endings.  
Dispose of old Module.  
5
4
6
Module wires are in pairs.  
Black to black and  
red with white stripe to same.  
Black and white attach to black and  
white Control wires.  
Get new Module*, 4 wire nuts,  
and 4 grease caps.  
Insert all wire nuts into  
grease caps and snap closed.  
Insert all wire ends into wire nuts.  
*
Remember to record new  
Module address for re-entry at  
the Central Controller!  
7
8
Operating the INFINITY™  
!
sprinkler without the cover or  
with loose or missing cover  
screws may shorten the expected  
service life of the sprinkler.  
Replace the cover and  
secure all 3 screws to  
25 inch/pounds of torque.  
Put Module and all wiring carefully  
back into sprinkler body.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Service the Pilot Valve  
e pilot valve can be replaced while the system is under pressure. Remove the pilot valve for service.  
1
2
Remove screw securing  
pilot valve assembly.  
Carefully slide assembly out.  
Refer to Figure 1 for pilot valve service issues.  
1. Unthread solenoid (17), unthread thumbnut (7), and remove  
locator (6).  
Figure 1  
2. Remove diaphragm assembly (1), piston (2), spring (3), traveling  
adjuster (4), pressure adjuster (5) and o-ring (11).  
3. Remove selector shaft (10) and plunger assembly (12). (e selector  
shaft retains the plunger in the valve body.)  
4. oroughly clean and inspect all parts. Ensure threads are clean on  
solenoid and PV body prior to assembly. Replace damaged parts  
as necessary and reassemble in reverse order. Improper solenoid  
assembly or cross-threading may result in damage to PV body and/or  
malfunctions.  
Pilot Valve Parts Breakout  
1. 118-1825  
2. 102-2469  
3. 102-2235  
4. 102-2236  
5. 102-2237  
6. 102-2606  
7. 343-4441  
8. 118-3711  
9. 1-2035  
10. 102-4831  
11. 360-0220  
12. 118-1740  
13. 118-0248  
13. 102-3443  
13. 102-3444  
13. 102-2709  
13. 118-0841  
14. 4102001  
15. 118-1816  
16. 2-9654  
Diaphragm, Welded  
Piston, PV, adjustable  
Spring, adjustable PV  
Nut, traveling  
Adjuster, PV  
Locator, Pressure Setting  
Nut, umb  
PV, Body, Infinity  
O-ring  
Selector, PV, red (included item 9)  
O-ring  
Plunger  
Solenoid, Standard  
Solenoid, SPIKE GUARD  
Solenoid, Nickel plated, SPIKE GUARD  
Solenoid, DC Latching  
GDC Module w/ DC Latching Solenoid  
Screw, #10 x 1”, Tapping, SS  
Housing, Pilot Valve  
O-ring  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Replace the Pilot Valve Solenoid  
ere are two Step 1s, depending on which version of the INFINITY Series sprinkler is being serviced.  
1
1
2
Unscrew old solenoid and dispose.  
Flush plunger area with clean  
water. Screw on new solenoid.  
With Intelligence Module:  
Cut solenoid red with white stripe  
Without Intelligence Module:  
Cut black and white Control wires.  
and black wires.  
3
4
5
Solenoid to Intelligence Module:  
twist red-to-red and black-to-black.  
Solenoid to Satellite Control wires:  
Match wire colors with previous  
installation.  
Insert all wire nuts into  
grease caps and snap closed.  
Strip 7/16” (11 mm) wire  
from each ending.  
Insert all ends into wire nuts.  
6
Put pilot assembly and wiring  
carefully back into sprinkler body  
and secure with screw.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Remove the Sprinkler Riser Assembly  
1
2
3
995-83  
Insert the multipurpose tool  
into slot of riser cap.  
Tilt tool back to lock it in.  
With multipurpose tool,  
push seal retainer down hard to  
release snap ring.  
Pull up riser and grasp firmly.  
4
6
5
Carefully remove the riser  
assembly. The spring will push  
against your hand.  
Insert multipurpose tool  
into snap ring slot.  
Twist and remove snap ring.  
7
118-0954  
Insert the “hold up” tool into nozzle  
notch and riser spring collar.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For INF34 and INF54 Sprinklers (Full Circle only)  
2
1
Figure 8  
Refer to Figure 8 for the following procedure.  
3
1. Grasp return spring (14) and riser (16) firmly and hold in place  
while removing nozzle base (4). Turn nozzle base assembly  
counter-clockwise to remove.  
5
6
15  
4
7
2. Carefully release tension from return spring.  
8
10  
9
16  
3. Remove spring and seal retainer/o-ring assembly (12 and 13).  
4. Remove riser screen (19) by turning it counterclockwise with edge  
of multi-purpose tool (P/N 995-83) or tips of snap ring pliers  
(P/N 995-100).  
7
11  
5. Remove o-ring (15) from top of riser assembly.  
6. Remove drive assembly (17) and stator (18) from riser assembly  
by carefully pressing on end of threaded shaft.  
12  
17  
7. Using a 5/8” nut driver (P/N 995-99), unscrew main nozzle  
(10) from nozzle housing (8). e riser cap (3) must still be  
attached to the nozzle base assembly (4), or the nozzle housing  
(8) will turn instead of the main nozzle.  
13  
18  
19  
8. Using a 5/16” nut driver (P/N 995-105), unscrew intermediate  
nozzle (6) and inner nozzle (5) and plugs (7) from the nozzle  
base assembly.  
14  
9. oroughly clean and inspect all parts and replace as necessary.  
During reassembly, ensure snap ring is correctly installed and  
fully seated in snap ring groove. Use the Multipurpose tool to  
assist in proper placement.  
For INF35 and INF55 Sprinklers (Full/Partial Circle)  
Refer to Figure 9 for the following procedure.  
Figure 9  
1
2
8
7
10  
1. Remove riser screen (17) by turning it counterclockwise  
with edge of multi-purpose tool (P/N 995-83) or tips of  
snap ring pliers (P/N 995-100).  
12  
2. Remove the variable stator (16) from riser assembly.  
3
4
9
3. Loosen the drive assembly retaining screw (14) six or  
seven turns and pull the drive assembly (15) using a pair  
of pliers.  
11  
13  
CAUTION: When removing or installing the drive  
!
assembly, do not use the turbine to pull the drive  
assembly. Use the drive assembly body to extract it out.  
Failure to comply may cause separation of the drive  
assembly components.  
15  
14  
5
During reassembly, ensure drive assembly is properly  
aligned with the retaining screw.  
16  
17  
4. Using a 5/8” nut driver (P/N 995-99), unscrew main  
nozzle (9) from nozzle base assembly.  
5. Using a 5/16” nut driver (P/N 995-105), unscrew the  
inner (8), intermediate (7) nozzles, and plug (12).  
6
6. oroughly clean and inspect all parts and replace as  
necessary.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Install the INF35 and INF55 Sprinkler Riser Assemblies  
1
2
3
Insert the “hold up” tool into nozzle  
Note locations of alignment  
notch and rib.  
Center the ratchet ring on the  
alignment notch and insert riser.  
notch and riser spring collar.  
4
5
6
Press retainer / o-ring assembly  
down below snap ring groove.  
Put snap ring, stepped side up,  
around riser body.  
Push snap ring down  
until it “snaps” into place.  
The multipurpose tool can help.  
Remove “hold up” tool and lower  
riser to retracted position.  
To Install the INF34 and INF54 Sprinkler Riser Assembly  
To install the INF34 and/or the INF54, follow the steps above except for the steps 2 and 3; those are not necessary.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Service the Main Valve and Rock Screen  
WARNING: To service the main valve, the water supply to sprinkler must be shut off and any residual water bled  
off.  
!
WARNING  
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS  
BEING FILLED, DURING MANUAL OR AUTOMATIC OPERATION, OR WHEN PERFORMING  
SPRINKLER SERVICE PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED  
OR IMPROPERLY INSTALLED SPRINKLER CONNECTION, OR SPRINKLER COMPONENTS  
FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.  
e riser assembly must be removed from the sprinkler body to service the main valve. See page 11 to remove riser assembly.  
1
2
3
995-100  
Place the manual selector  
into the ON position to ensure  
water is off and pressure relieved.  
Use long pliers to push down on  
center of valve cylinder.  
You will need long pliers  
(part number 995-100).  
5
6
4
Grab the hook that is furthest out  
and pull up while twisting.  
Then grasp snap ring at “hooks”  
and squeeze together.  
Using the pliers,  
remove main valve assembly.  
8
7 - Service the Rock Screen  
Using the pliers,  
Using the pliers, press the rock  
screen back into position.  
remove the rock screen.  
Clean or replace as necessary.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Reinstall Main Valve  
Use the valve insertion tool. ere are two sizes of the tool depending on the size of the sprinkler inlet.  
118-1843 is the 1.5” (40 mm) valve insertion tool  
118-1844 is the 1” (25 mm) valve insertion tool  
3
1
2
“Step” side of ring faces up.  
Ring “hooks” are hooked  
around insertion tool prongs.  
Align valve communication port  
with notch on insertion tool.  
Load valve assembly onto tool.  
Load snap ring onto insertion tool.  
Trigger is in “down” position.  
4
5
6
Push tool down completely then pull  
up on “trigger” to release the snap  
ring.  
Align the tool handle, the snap ring,  
and the valve with the notch in body.  
Insert valve assembly.  
7
8
Replace riser assembly.  
(See page 13 for full procedure.)  
Remove tool.  
e snap ring will “snap!” into groove when properly installed. Remove insertion tool and check snap ring to confirm  
that it is fully seated in groove.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flushing the Sprinkler  
1. With sprinkler operating, carefully step down on center of cap several times. Water will flow around riser and flush out debris.  
2. Cycle sprinkler on and off several times to check for proper retraction. Cap should be even with top of body flange when fully retracted. If  
riser sticks in up position, check for debris lodged between riser and body. Flush out all debris. Remove riser assembly if necessary.  
Troubleshooting Guide  
Problem  
Cause  
Solution  
Sprinkler will not turn on.  
Measure voltage with a Digital Volt Meter.  
Check wiring and controller program.  
No 24 VAC to solenoid assembly.  
Disassemble and remove all debris.  
(See Servicing Pilot Valve, page 9.)  
Debris in pilot valve assembly.  
Set to “AUTO” position.  
Remove and replace solenoid.  
Inspect, clean, and/or replace.  
Debris in control tube, main valve assembly, and/or  
communication passages in body. Flush thoroughly.  
Selector cam in “OFF” position.  
Pilot valve solenoid inoperative.  
Pilot valve plunger movement restricted.  
No water supply from main valve.  
Sprinkler will not shut off.  
Check for voltage using a DVM. If voltage is present,  
disconnect wire. If sprinkler closes, service controller.  
Refer to Controller Service Manual.  
Constant 24 VAC from controller  
Set to “OFF” position.  
Disassemble and remove all debris.  
(See Servicing Pilot Valve, page 14.)  
Selector cam in “ON” position.  
Debris in pilot valve assembly.  
Replace pilot valve assembly.  
Leak in pilot valve assembly.  
Plugged supply screen on piston.  
Plunger movement restricted.  
Clean or replace screen on main valve piston.  
Inspect and clean or replace.  
Remove valve assembly and install correctly.  
Valve cylinder misaligned with sprinkler  
body communication tube.  
Remove, clean, and check for valve damage.  
Replace if necessary.  
Foreign object keeping valve from seating.  
Replace valve assembly.  
Damaged piston seal or piston assembly.  
Debris wedged between stator and turbine.  
Drive assembly defective.  
Nozzle base assembly defective.  
Dirt in riser assembly.  
Sprinkler will not rotate.  
Head sticks up  
Remove obstruction.  
Replace drive assembly.  
Replace nozzle base assembly.  
Flush out. (See top of this page.)  
Replace spring.  
Damaged or missing return spring.  
Damaged riser.  
Replace riser.  
Poor distribution pattern  
Clean or replace nozzle.  
Replace nozzle.  
Nozzle plugged with debris.  
Nozzle orifice damaged.  
Determine why system is overloaded and correct.  
Low operating pressure.  
Toro Warranty and Support  
e Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrants, to the owner, against defects in  
material and workmanship for a period of three years from the date of purchase. (Five years if Toro Swing Joint installed with sprinkler.) Neither e Toro  
Company nor Toro Warranty Company is liable for failure of products not manufactured by them, even though such products may be sold or used in  
conjunction with Toro products.During such warranty period, we will repair or replace, at our option, any part found to be defective. Return the defective  
part to the place of purchase. Our liability is limited solely to the replacement or repair of defective parts. ere are no other express warranties. is  
warranty does not apply where equipment is used, or installation is performed, in any manner contrary to Toro’s specifications and instructions, nor where  
equipment is altered or modified. Neither e Toro Company nor Toro Warranty Company is liable for indirect, incidental or consequential damages in  
connection with the use of equipment, including but not limited to: vegetation loss, the cost of substitute equipment or services required during periods of  
malfunction or resulting non-use, property damage or personal injury resulting from installer’s negligence.  
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.  
All implied warranties, including those of merchantability and fitness for use, are limited to the duration of this express warranty. Some states do not allow  
limitations of how long an implied warranty lasts, so the above limitation may not apply to you. is warranty gives you specific legal rights and you may  
have other rights which vary from state to state.  
Form Number 373-0798 Rev. B  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam CD Player D01064220C User Manual
Technicolor Thomson Stereo System CS700 User Manual
Thermaltake Computer Hardware AF0018 User Manual
Toastmaster Fryer Gas Electric Fryer User Manual
Toshiba All in One Printer e Studio 165 205 User Manual
Ultra Products Network Card m998 User Manual
Uniden Cordless Telephone TRU9385 User Manual
ViewSonic Projector PJD5226 User Manual
VocoPro DVD Player DVG 777K User Manual
Wagner SprayTech Paint Sprayer HC920 User Manual