General Operation (cont.)  
Precautions  
TE150 / TE400  
This scale is engineered to give you years of satisfactory service  
if you handle it carefully. Here are a few precautions:  
1. Always read instructions thoroughly to ensure that you have  
OVERLOAD  
The scale can be overloaded by a maximum of 5% above the  
scale's capacity, as follows:  
Max Load  
TE150  
TE400  
the full benefit of all the unit's features.  
2. DO NOT immerse unit in water, as doing so will cause  
damage to internal components and void the warranty. If you  
spill liquid on it, dry it immediately with a soft, lint-free cloth.  
157.4 lb / 71.4 kg  
420 lb / 190.4 kg  
Digital  
Receiving Scale  
3. DO NOT clean the unit with an abrasive or corrosive  
material. This may scratch the plastic parts and corrode the  
electronic circuits.  
4. DO NOT subject the units to excessive force, shock, dust,  
temperature or humidity. This may result in malfunction,  
shorter electronic life span, damaged battery and distorted parts.  
5. DO NOT tamper with the unit's internal components.  
Doing so will invalidate the warranty on the units and may  
cause damage. The unit contains no user-serviceable parts.  
7. Only use fresh batteries, as old batteries may leak and cause  
damage to the unit. Remove the batteries if the scale will not  
be used for a long period of time.  
POWER OFF  
To turn the scale off, press the “OFF” button.  
Calibration Function  
Occasionally the scale's accuracy should be verified by  
measuring a known weight of the scale's approximate capacity.  
Tare the scale by pressing ZERO, place the weight on the  
platform and note the reading. Calibrate the scale if necessary.  
®
Leading the Way in Accuracy  
Calibration Procedure  
You must use a CALIBRATED weight ONLY to properly  
recalibrate the scale.  
For the TE150, use a 150 lb calibrated weight (or 60 kg if  
operating in kilos).  
For the TE400, use a 400 lb calibrated weight (or 150 kg if  
operating in kilos).  
1. While the scale is off, press and hold down the  
“TARE/HOLD” and “lb/kg” buttons. While holding down  
both these buttons, press the “ON” button to turn the scale  
on. When the display shows “8888” > “CAL, the scale is in  
calibration mode.  
2. Release the buttons. The display will show “CX” with a  
number (CX150 for the TE150; CX400 for the TE400).  
Next the display will show a number (the zero count)  
between 4700 and 6000. (Note: if operating the scale in  
kilograms, the scale will instead show “C60” for the TE150  
or “C150” for the TE400. If the zero count is outside the  
range, please contact customer service.)  
8. DO NOT dispose of batteries in fire. Disposing of this  
product in fire could cause batteries to explode or leak.  
Specifications  
Platform Size: 8-1/16” x 5”  
Power: 120V adaptor (included) or six (6) AAbatteries (not  
included)  
Dimensions: 12 1/4” x 12” x 2 1/8”  
Weight: 9 3/4 lbs / 4.4 kgs  
Operating Temperature Range: 40°F to 104°F  
Accuracy: +/-1% + 1 division  
Capacity: TE150 150 lbs x 0.2 lb  
150 lbs x ¼ lb  
68 kgs x 0.1 kg  
TE400 400 lbs x 0.5 lb  
400 lbs x ½ lb  
181 kgs x 0.2 kg  
Overload:TE150 157.4 lbs / 71.4 kgs  
TE400 420 lbs / 190.4 kgs  
Platform: TE150 Stainless steel  
TE400 Tread painted steel  
3. Press the “TARE/HOLD” button. The display will show  
“XXX0”.  
4. Place a calibrated weight on the scale platform.  
For the TE150, use a 150lb (or 60 kg) calibrated weight.  
For the TE400, use a 400 lb (or 150 kg) calibrated weight.  
The display will show a number between 1800 and 2300 (the  
span count). Note: the span count must be stable on the  
display before proceeding to step 5. If the span count is  
outside this range, please contact customer service  
5. Press the “TARE/HOLD” button. The following will appear  
on the display:  
For the TE150, the display will show “C150”> “End”>  
“150.0”  
(or “C60”> “End”> “60.0” if operating in kilograms).  
For the TE400, the display will show “C400”> “End”>  
“400.0”  
(or “C120”> “End”> “120.0” if operating in kilograms).  
6. The calibration is complete. Remove the weight from the  
scale.  
One Year Limited Warranty  
This product is warranted against defects in materials or  
workmanship for one (1) year from date of original purchase.  
It does not cover damages or wear resulting from accident,  
misuse, abuse, or unauthorized adjustment and/or repair.  
Should this product require service (or replacement at our  
option) while under warranty, please pack the item carefully  
and return it prepaid, along with receipt showing date of  
purchase and a note explaining reason for return to:  
Taylor Precision Products  
2220 Entrada Del Sol, Suite A  
Las Cruces, New Mexico 88001  
Customer Service Phone: 1-800-225-4834  
Customer Service Fax: 1-575-526-4347  
Instruction Manual  
There are no expressed warranties except as listed above. This  
warranty gives you specific legal rights, and you may also have  
other rights which vary from state to state.  
©2009 Taylor Precision Products and its affiliated companies, all rights reserved. Taylor®  
and Leading the Way in Accuracy® are registered trademarks of Taylor Precision Products  
and its affiliated companies. All rights reserved.  
Display Signals  
Thank you for purchasing a Taylor® Digital Receiving Scale.  
Your scale is an example of superior design and craftsmanship.  
In order to optimize its function, be sure the read this  
instruction manual carefully before use. Keep instructions  
handy for future reference.  
LCD Shows  
Low Battery ••••••••••••••••••• bAtt  
Load is greater than  
Maximum Overload ••••••••••••• oooo  
Made to our exact specifications in China.  
NOT LEGAL FOR TRADE  
TE150/TE400 11.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson MP3 Player PDP2211 User Manual
Technics Stereo System SC S305 User Manual
Toastmaster Toaster TMT2 User Manual
Toshiba Computer Drive MK5002MPL User Manual
Transcend Information MP3 Player TS128 User Manual
Velodyne Acoustics Speaker FSX 12 User Manual
Viking Ventilation Hood F20470I EN User Manual
Vinotemp Refrigerator VINO1500CD User Manual
VTech Cordless Telephone VT20 2420 User Manual
Wagner SprayTech Paint Sprayer 292003 User Manual