IMPORTANT–Please Read and Follow!  
Dimensions & Specifications  
(VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”)  
W A R N I N G  
To reduce the risk of injury to persons in the  
event of a rangetop grease fire, observe the  
following. (Based on “Kitchen Firesafety Tips,”  
published by NFPA.)  
1. SMOTHER FLAMES with a close fitted lid, cookie  
sheet, or metal tray, then turn off the burner. BE  
CAREFUL TO PREVENT BURNS. If the flames do  
not go out immediately, EVACUATE AND CALL  
THE FIRE DEPARTMENT.  
2. NEVER PICK UP A FLAMING PAN. You may be  
burned.  
3. DO NOT USE WATER, including wet dishcloths or  
towels a violent steam explosion will result.  
4. Use an extinguisher ONLY if  
You know it is a Class ABC extinguisher, and you  
already know how to operate it.  
• The fire is small and contained in the area where  
it started.  
• The fire department is being called.  
You can fight the fire with your back to an exit.  
C A U T I O N  
For general ventilating use only. Do not use to  
exhaust hazardous or explosive materials and  
vapors.  
NOTE: Optional duct cover sold separately.  
VWH 10”H. Wall Hoods w/Standard Ventilator  
Description  
Duct cover width  
Duct cover depth  
Duct cover height  
Number of lights  
Number of filters  
Heat lamps  
24”  
30”  
36”  
W A R N I N G  
23-7/8” (60.6 cm)  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
TO REDUCE THE RISK OF FIRE,  
ELECTRICAL SHOCK, OR INJURY  
12” (30.5 cm)  
TO PERSONS  
Rangehoods must be installed with  
the ventilators that are specified on  
their carton indicating suitability with  
12” (30.5 cm)  
2
2
N/A  
this model. Other ventilators cannot be substituted.  
Interior ventilator kit  
Interior duct size*  
Interior—Maximum amps  
460 CFM Standard  
7” (17.8 cm)  
5.6  
* Disregard when using recirculating kits.  
460 CFM blower is shipped with hood.  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clearance Dimensions  
Interior Ventilator Dimensions  
(VWH 10”H. Wall Hoods w/Standard Ventilator)  
(VWH 10”H. Wall Hoods w/Standard Ventilator)  
Top View  
460 CFM Interior Ventilator Installation  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clearance Dimensions  
Dimensions & Specifications  
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)  
(VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)  
(VWH 18”H. Wall Hoods)  
NOTE: Optional duct cover sold separately.  
VWH 18”H. Wall Hoods  
Description  
30”  
36”  
42”  
48”  
54”  
60”  
Duct cover width  
29-7/8”  
(75.9 cm)  
35-7/8”  
(91.1 cm)  
41-7/8”  
(106.4 cm)  
47-7/8”  
(121.6 cm)  
53-7/8”  
(136.8 cm)  
59-7/8”  
(152.1 cm)  
Duct cover depth  
Duct cover height  
Number of lights  
Number of filters  
12” (30.5 cm)  
12” (30.5 cm)  
2
2
1
2
2
1
2
2
3
3
2
3
4
3
4
Heat lamps  
1
2
2
VINV300/  
600/1200  
VINV300/  
600/1200  
VINV600/  
1200  
VINV1200*  
VINV1200*  
VINV1200*  
Interior ventilator kits  
DEV900/  
1200*  
DEV900/  
1200*  
DEV900/  
1200*  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
Exterior ventilator kits  
DIL900/1200  
DIL900/1200  
DIL900/1200  
DIL1200  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
7”/10”  
(17.8/25.4 cm)  
7”/10”  
7”/10”  
10”  
(25.4 cm)  
10”  
(25.4 cm)  
10”  
(25.4 cm)  
(17.8/25.4 cm) (17.8/25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
4.9/5.9  
8.7/6.0  
4.9/5.9  
8.7/6.0  
11.5  
11.5  
11.5  
11.5  
Interior—Maximum amps  
Exterior—Maximum amps  
8.7/6.0  
8.5/9.2  
8.5/9.2  
8.9/9.2  
6.0/7.9  
6.0/7.9  
6.0/7.9  
10.3  
10.3  
10.7  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Exterior Ventilator Dimensions  
(VWH 18”H. Wall Hoods)  
(VWH 18”H. Wall Hoods)  
Top View  
Top View  
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all  
Wall Hoods  
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods  
Top View  
Top View  
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all  
Wall Hoods  
1200 CFM Interior Ventilator Installation for all Wall Hoods  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clearance Dimensions  
Dimensions & Specifications  
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)  
(VWHO 18”H. Outdoor Wall Hoods)  
NOTE: Optional duct cover sold separately.  
VWHO 18”H. Outdoor Wall Hoods  
Description  
Duct cover width  
Duct cover depth  
Duct cover height  
Number of lights  
Number of filters  
Interior ventilator kits  
Exterior ventilator kits  
In-line ventilator kits  
Interior duct size  
36”  
48”  
47-7/8” (121.6 cm)  
12” (30.5 cm)  
12” (30.5 cm)  
3
60”  
35-7/8” (91.1 cm)  
59-7/8” (152.1 cm)  
2
2
4
4
3
VINV1200*  
DEV1200*/1500**  
DIL1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
11.4  
Interior—Maximum amps  
Exterior—Maximum amps  
In-Line—Maximum amps  
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from  
the elements as much as possible.  
9.0  
6.1/6.8  
7.9  
11.8  
8.8/9.5  
10.6  
8.4/9.1  
10.2  
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood  
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back  
wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces, and a 24”  
minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible  
material used for this purpose must be covered with locally-supplied stainless steel. Viking also  
recommends using a backsplash.  
* A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when indoor models are  
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”)  
(VCWH Chimney Wall Hoods)  
NOTE: Optional duct cover sold separately.  
VCWH Chimney Wall Hoods  
Description  
30”  
36”  
42”  
48”  
54”  
60”  
66”  
Duct cover width  
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm)  
Duct cover depth  
Duct cover height  
Number of lights  
Number of filters  
12” (30.5 cm)  
12” (30.5 cm) to 24” (61.0 cm)  
2
2
1
2
2
1
2
2
3
2
3
3
4
3
4
3
Heat lamps  
1
2
2
2
2
VINV300/600 VINV300/600  
VINV600  
VINV1200*  
VINV1200*  
VINV1200*  
VINV1200*  
Interior ventilator kits  
Exterior ventilator kits  
DEV900/  
1200*  
DEV900/  
1200*  
DEV900/  
1200*  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
DIL900/1200 DIL900/1200 DIL900/1200  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
7” (17.8 cm) 7” (17.8 cm)  
7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
4.9/5.9  
8.7/6.0  
4.9/5.9  
8.7/6.0  
5.9  
11.5  
11.5  
11.9  
11.9  
Interior—Maximum amps  
Exterior—Maximum amps  
8.7/6.0  
8.5/9.2  
8.5/9.2  
8.5/9.2  
8.5/9.2  
6.0/7.9  
6.0/7.9  
6.0/7.9  
10.3  
10.3  
10.7  
10.7  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Exterior Ventilator Dimensions  
(VCWH Chimney Wall Hoods)  
(VCWH Chimney Wall Hoods)  
Top View  
Top View  
900 or 1200 CFM Exterior or In-Line Ventilator Installation  
for 30”, 36”, & 42” models  
300 or 600 CFM Interior Ventilator Installation  
for 30”, 36”, & 42” models  
Top View  
Top View  
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
for 48”, 54”, 60”, & 66” models  
1200 CFM Interior Ventilator Installation  
for 48”, 54”, 60”, & 66” models  
16  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(DCWH Classic Chimney Hoods)  
(DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”)  
DCWH Classic Chimney Wall Hoods  
Description  
30”  
36”  
42”  
48”  
Duct cover width  
10” (25.4 cm)  
12” (30.5 cm)  
12” (30.5 cm)  
18” (45.7 cm)  
Duct cover depth  
Duct cover height  
12” (30.5 cm)  
18” (45.7 cm) to  
30” (76.2 cm)  
16” (40.6 cm) to  
28” (71.1 cm)  
16” (40.6 cm) to  
28” (71.1 cm)  
16” (40.6 cm) to  
28” (71.1 cm)  
Number of lights  
2
2
2
3
3
3
Number of filters  
2
2
VINV300/600  
DEV900/1200*  
VINV300/600  
DEV900/1200*  
VINV600  
DEV900/1200*  
VINV1200*  
DEV1200*/1500**  
Interior ventilator kits  
Exterior ventilator kits  
DIL900/1200  
7” (17.8 cm)  
DIL900/1200  
7” (17.8 cm)  
DIL900/1200  
7” (17.8 cm)  
DIL1200  
In-line ventilator kits  
Interior duct size  
10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
2.8/3.8  
6.6/3.9  
3.9/5.7  
2.8/3.8  
6.6/3.9  
3.9/5.7  
3.8  
7.3  
4.3/5.1  
6.1  
Interior—Maximum amps  
NOTE: For best performance, it is recommended  
that the bottom of the hood be 30” (76.2 cm) to  
36” (91.4 cm) above the countertop. These dimensions  
provide for safe and efficient operation of the hood.  
6.6/3.9  
3.9/5.7  
Exterior—Maximum amps  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
18  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Exterior Ventilator Dimensions  
(DCWH Classic Chimney Hoods)  
(DCWH Classic Chimney Hoods)  
Top View  
Top View  
300 or 600 CFM Interior Ventilator Installation  
for 30”, 36”, & 42”Hoods  
900 or 1200 CFM Exterior or In-Line Ventilator Installation  
for 30”, 36”, & 42” Hoods  
Top View  
Top View  
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
for 48” Hoods  
1200 CFM Interior Ventilator Installation  
for 48” Hoods  
20  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)  
(VCIH Chimney Island Hoods)  
NOTE: Optional duct cover sold separately.  
VCIH Chimney Island Hoods  
Description  
36”  
42”  
54”  
66”  
Duct cover width  
12” (30.5 cm)  
12” (30.5 cm)  
18” (45.7 cm)  
24” (70.0 cm)  
Duct cover depth  
Duct cover height  
Number of lights  
Number of filters  
12” (30.5 cm)  
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)  
4
4
4
4
6
6
8
8
Heat lamps  
N/A  
VINV600  
DEV900/1200*  
DIL900/1200  
7” (17.8 cm)  
VINV600  
DEV900/1200*/1500**  
DIL900/1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
Interior ventilator kits  
Exterior ventilator kits  
In-line ventilator kits  
Interior duct size  
7” (17.8 cm)  
10” (25.4 cm)  
10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
4.6  
4.6  
8.9  
5.6/6.4  
7.4  
9.3  
6.4/7.4  
7.4  
Interior—Maximum amps  
Exterior—Maximum amps  
In-Line—Maximum amps  
7.4/4.7  
4.7/6.5  
7.4/4.7/5.5  
3.9/5.7  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
22  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Exterior Ventilator Dimensions  
(VCIH Chimney Island Hoods)  
(VCIH Chimney Island Hoods)  
Top View  
Top View  
600 CFM Interior Ventilator Installation  
for all Chimney Island Hoods  
900 or 1200 CFM Exterior or In-Line Ventilator Installation  
for all Chimney Island Hoods  
Top View  
Top View  
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
for all Chimney Island Hoods  
1200 CFM Interior Ventilator Installation  
for all Chimney Island Hoods  
24  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing Hood Canopy  
Dimensions & Specifications  
(VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”)  
(Custom Hood Canopy Cutouts)  
Custom Hood  
Canopy  
Make sure the back wall  
of the custom hood  
canopy is flush with the  
cutout so the ventilator  
system may be mounted  
as shown on page 25.  
*For best results,  
center the unit over  
the burners of the  
cooking product  
(front to back; right  
to left).  
Bottom Cutout Dimensions  
Wall Hoods  
Description  
30” W.  
A (Hood Width)  
27-7/16” (69.7 cm)  
33-7/16” (84.9 cm)  
39-7/16” (100.2 cm)  
45-7/16” (115.4 cm)  
51-7/16” (130.7 cm)  
57-7/16” (145.9 cm)  
63-7/16” (161.1 cm)  
B (Hood Depth)  
21-7/16” (54.5 cm)  
36” W.  
42” W.  
48” W.  
54” W.  
60” W.  
66” W.  
21-7/16” (54.5 cm)  
21-7/16” (54.5 cm)  
21-7/16” (54.5 cm)  
21-7/16” (54.5 cm)  
21-7/16” (54.5 cm)  
21-7/16” (54.5 cm)  
1) Position ventilator  
system inside of the  
custom hood canopy  
and center it front to  
back and left to right.  
Built-In Ventilator  
System  
VBCV Wall Custom Ventilator System  
Description  
Number of lights  
Number of filters  
Heat lamps  
30”  
36”  
42”  
48”  
54”  
60”  
66”  
2) Bottom mounting holes  
fasten ventilator system  
to bottom of custom  
hood canopy with the  
screws provided.  
2
2
1
2
2
1
2
2
1
3
3
2
3
3
2
4
4
2
4
4
2
VINV300/  
600/1200*  
VINV300/  
600/1200*  
VINV600/ VINV1200* VINV1200* VINV1200* VINV1200*  
1200*  
Interior ventilator kits  
DEV900/  
1200*  
DEV900/  
1200*  
DEV900/  
1200*  
DEV1200*/ DEV1200*/ DEV1200*/ DEV1200*/  
Exterior ventilator kits  
3) OPTIONAL  
1500**  
1500**  
1500**  
1500**  
Rear mounting holes fasten  
ventilator system to rear of  
custom hood canopy.  
DIL900/1200 DIL900/1200 DIL900/1200  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
7”/10”  
7”/10”  
7”/10”  
10”  
10”  
10”  
10”  
(17.8/25.4 cm) (17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
5.9/9.0  
8.7/6.0  
5.9/9.0  
8.7/6.0  
5.9/9.0  
8.7/6.0  
11.5  
11.5  
11.9  
11.9  
Interior—Maximum amps  
Exterior—Maximum amps  
8.5/9.2  
8.5/9.2  
8.9/9.2  
8.9/9.2  
6.0/7.9  
6.0/7.9  
6.0/7.9  
10.3  
10.3  
10.7  
10.7  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft.  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
26  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clearance Dimensions  
Built-In Wall Custom Ventilator  
(VBCV Wall Custom Ventilator System)  
System Dimensions  
(VBCV Models)  
For 300, 600 or 1200 CFM Interior  
Ventilator Installation  
For 900, 1200 or 1500 CFM Exterior  
or In-Line Ventilator Installation  
900 or 1200 CFM Exterior  
or In-Line Ventilator Installation  
30”, 36”, 42” W. Models  
300 or 600 CFM Interior  
Ventilator Installation  
30”, 36”, 42” W. Models  
D
C
30” W.  
36” W.  
42” W.  
14-1/8” (35.9 cm)  
17-1/8” (43.5 cm)  
20-1/8” (51.1 cm)  
30” W.  
36” W.  
42” W.  
28-1/4” (71.8 cm)  
34-1/4” (87.0 cm)  
40-1/4” (102.2 cm)  
28  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Built-In Wall Custom Ventilator  
System Dimensions  
(VBCV Models)  
Proper installation of ducting is extremely  
important to ensure maximum performance  
from any ventilation product.  
• All CFMs are based on tests at 0.1 static  
pressure: without applying static pressure, CFM  
would be greatly overstated.  
• Straight runs and gradual turns are best; for  
example, each 90º elbow is equivalent to 5-10  
feet (1.52-3.05 cm) of straight run.  
• Never use flexible duct; it creates back pressure/air  
turbulence and greatly reduces performance.  
• Proper performance is dependent on proper  
ducting; make sure that a qualified and trained  
installer is used.  
• Check with a qualified and trained installer or  
local codes for makeup air requirement, if any.  
• Max. amp rating for hoods includes  
recommended ventilator kit rating; all products  
must be hard wired direct with 2-wire with ground.  
1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
48”, 54”, 60”, 66” W. Models  
Plan where the duct work will be located. Install  
proper-sized duct work, and roof or wall cap for the  
type of blower you are using. Recommended hood  
locations for the most common installations are  
shown. Adjust your measurements for various heights  
of ceilings, soffits, cabinets, or ranges/rangetops.  
Check Framing  
1200 CFM Interior Ventilator Installation  
30”, 36”, 42”, 48”, 54”, 60”, 66” W. Models  
C
D
30” W.  
36” W.  
42” W.  
48” W.  
54” W.  
60” W.  
66” W.  
28-1/4” (71.8 cm)  
34-1/4” (87.0 cm)  
40-1/4” (102.2 cm)  
46-1/4” (117.5 cm)  
52-1/4” (132.7 cm)  
58-1/4” (148.0 cm)  
64-1/4” (163.2 cm)  
30” W.  
36” W.  
42” W.  
48” W.  
54” W.  
60” W.  
66” W.  
14-1/8” (35.9 cm)  
17-1/8” (43.5 cm)  
20-1/8” (51.1 cm)  
23-1/8” (58.7 cm)  
26-1/8” (66.4 cm)  
29-1/8” (74.0 cm)  
32-1/8” (81.6 cm)  
NOTE: Because of the weight of the hood make sure  
that the mounting screws are driven into the framing  
and not just the drywall. It may be necessary to drill  
additional holes in the canopy for proper alignment.  
30  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator)  
Text goe here.  
necessary.  
Check damper for unrestricted movement, adjust if  
Text goe here.  
Attach transition to damper. Seal with aluminum tape.  
CAUTION: If not using a duct cover, using screws  
provided, make sure top mounting screws are secured  
into soffit or cabinet framing. Use additional mounting  
screws, if necessary.  
provided. Use additional mounting screws and wall  
anchors, if necessary.  
W A R N I N G  
To reduce the risk of fire, electric shock, or injury  
to persons, observe the following:  
• Use this unit only in the manner intended by the  
manufacturer. If you have any questions, contact  
the manufacturer.  
• Before servicing or cleaning unit, switch power off  
at service panel and lock service panel to prevent  
power from being switched on accidentally. When  
the service disconnecting means cannot be locked,  
securely fasten a prominent warning device, such  
as a tag, to the service panel.  
Connect black to black, white to white, and the  
green/bare wire under the green screw.  
NOTE: Housing wiring must be properly installed for  
wiring to be correct when wiring unit.  
Flip hood over and remove electrical box cover.  
Text goe here.  
Text goe here.  
Replace electrical box cover. Make connection to  
breaker box.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip.  
Insert 6” of electrical wiring through the top of vent hood  
Text goe here.  
and secure using wiring restrain. Refer to local codes.  
Slide duct over transition and tape around joint.  
Text goe here.  
32  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Attach with screws and lock washers provided.  
Attach with screws.  
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)  
W A R N I N G  
To reduce the risk of fire, electric shock, or injury  
to persons, observe the following:  
• Use this unit only in the manner intended by the  
manufacturer. If you have any questions, contact  
the manufacturer.  
• Before servicing or cleaning unit, switch power off  
at service panel and lock service panel to prevent  
power from being switched on accidentally. When  
the service disconnecting means cannot be locked,  
securely fasten a prominent warning device, such  
as a tag, to the service panel.  
Remove electrical box cover.  
Measure distance from ceiling to canopy.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit)  
Flip hood over. Insert 6” of electrical wiring through the  
top of vent hood and secure. Refer to local codes.  
screws are secured into framing. Use additional  
mounting screws and wall anchors, if necessary.  
Remove damper and discard with transition.  
Turn recirculating unit upside down. Place vent hood  
upside down on recirculating unit.  
34  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods)  
Connect black to black, white to white, and the  
green/bare wire under the green screw.  
NOTE: Housing wiring must be properly installed for  
wiring to be correct when wiring unit.  
Replace electrical box cover. Make connection to  
breaker box.  
Measure down 1-13/16 (4.6 cm) from desired height of  
hood and secure 1-1/2” x 3/4” wood strip (provided  
locally) to wall using screws provided.  
Use additional mounting screws to secure hood to  
wood strip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
CAUTION: Secure vent hood to wall using screws  
provided. Use additional mounting screws and wall  
anchors, if necessary.  
CAUTION: If not using a duct cover, using screws  
provided, make sure top mounting screws are secured  
into soffit or cabinet framing use additional mounting  
screws, if necessary.  
Assemble brackets to baffles and insert charcoal filters.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip.  
36  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duct Cover Option (VCWH Chimney Wall Hoods)  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Measure distance from ceiling to canopy.  
Tape to avoid scratching.  
Duct Cover Option (VWH 18”H. Wall Hoods)  
Place duct cover top inside duct cover base and lower until  
desired height is found. Mark height. Use the retaining  
nuts and bolts to fasten in place and remove tape.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
Measure distance from ceiling to canopy.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
38  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (VCIH Island Hoods)  
Run duct work down to bottom edge of duct  
cover/soffit and secure in place. Make sure the duct  
does not stick down past the cover.  
Attach canopy to duct cover/soffit. Seal top of hood to  
duct with aluminum tape.  
Check framing where cutout will be.  
Cut appropriate size hole in ceiling. Either 7” or 10”  
depending on your specific unit and ventillator kit.  
NOTE: 200 lb. limit.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Attach duct cover to optional ceiling mounting bracket.  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip. NOTE: Number of spacers  
and baffles may vary by model.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Attach duct cover to ceiling. The ceiling bracket can be  
hidden by using a locally supplied trim.  
Additional support option. Drill holes in all four corners  
for threaded rod and run rods from hood to ceiling.  
40  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation(DCWH Classic Chimney Wall Hoods)  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Measure down 1-13/16 (4.6 cm) from desired height of  
hood and secure 1-1/2” x 3/4” wood strip (not  
included) to wall using screws provided.  
Use additional mounting screws to secure hood to  
wood strip.  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
CAUTION: Secure vent hood to wall using screws provided.  
Make sure mounting screws are secured into frame. Use  
additional mounting screws and wall anchors, if necessary.  
CAUTION: If not using a duct cover, using screws provided  
make sure top mounting screws are secured into soffit or  
cabinet frame. Use additional mounting screws, if necessary.  
Duct Cover Option (DCWH Classic Chimney Wall Hoods)  
Measure distance from ceiling to canopy.  
Tape to avoid scratching.  
42  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service & Registration  
Wiring Diagram  
Service & Parts  
Only authorized replacement parts may be  
used in performing service on the appliance.  
Do not repair or replace any part of the  
appliance unless specifically recommended in  
the manual. All other servicing should be  
referred to a qualified technician.  
PROFESSIONAL BUILT-IN HOODS  
Record the following information indicated  
below. You will need it if service is ever required.  
The serial number and model number for your  
appliance are located on the identification plate  
mounted on the inside of the hood canopy.  
Model number  
_________________________________________  
Serial number  
_________________________________________  
Date of purchase  
_________________________________________  
Date installed  
_________________________________________  
Dealer's name  
_________________________________________  
Address  
_________________________________________  
44  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam DJ Equipment LM 8ST User Manual
Thule Automobile Accessories Kit 202 User Manual
Transition Networks Switch SBFTF10XX 10X User Manual
TRENDnet Computer Accessories TRENDnet User Manual
TRENDnet Network Router TEW 632BRP User Manual
Troy Bilt Portable Generator 1924 User Manual
Uniden Two Way Radio UH088SX CB User Manual
Vidikron Home Theater Server VDP 80TM User Manual
Vision Fitness Treadmill TM357 User Manual
Weed Eater Lawn Mower Accessory 532 43 46 60 User Manual