Viking Installation Guide
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
Professional &
Outdoor Hoods
F20470I EN
(082012)
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT–Please Read and Follow!
Dimensions & Specifications
(VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”)
W A R N I N G
To reduce the risk of injury to persons in the
event of a rangetop grease fire, observe the
following. (Based on “Kitchen Firesafety Tips,”
published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you
already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
C A U T I O N
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
NOTE: Optional duct cover sold separately.
VWH 10”H. Wall Hoods w/Standard Ventilator
Description
Duct cover width
Duct cover depth
Duct cover height
Number of lights
Number of filters
Heat lamps
24”
30”
36”
W A R N I N G
23-7/8” (60.6 cm)
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY
12” (30.5 cm)
TO PERSONS
Rangehoods must be installed with
the ventilators that are specified on
their carton indicating suitability with
12” (30.5 cm)
2
2
N/A
this model. Other ventilators cannot be substituted.
Interior ventilator kit
Interior duct size*
Interior—Maximum amps
460 CFM Standard
7” (17.8 cm)
5.6
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Clearance Dimensions
Interior Ventilator Dimensions
(VWH 10”H. Wall Hoods w/Standard Ventilator)
(VWH 10”H. Wall Hoods w/Standard Ventilator)
Top View
460 CFM Interior Ventilator Installation
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Clearance Dimensions
Dimensions & Specifications
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
(VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)
(VWH 18”H. Wall Hoods)
NOTE: Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description
30”
36”
42”
48”
54”
60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
53-7/8”
(136.8 cm)
59-7/8”
(152.1 cm)
Duct cover depth
Duct cover height
Number of lights
Number of filters
12” (30.5 cm)
12” (30.5 cm)
2
2
1
2
2
1
2
2
3
3
2
3
4
3
4
Heat lamps
1
2
2
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
VINV1200*
Interior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
Exterior ventilator kits
DIL900/1200
DIL900/1200
DIL900/1200
DIL1200
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
7”/10”
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
(17.8/25.4 cm) (17.8/25.4 cm)
Exterior duct size
10” (25.4 cm)
4.9/5.9
8.7/6.0
4.9/5.9
8.7/6.0
11.5
11.5
11.5
11.5
Interior—Maximum amps
Exterior—Maximum amps
8.7/6.0
8.5/9.2
8.5/9.2
8.9/9.2
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VWH 18”H. Wall Hoods)
(VWH 18”H. Wall Hoods)
Top View
Top View
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
Top View
Top View
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
1200 CFM Interior Ventilator Installation for all Wall Hoods
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Clearance Dimensions
Dimensions & Specifications
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
(VWHO 18”H. Outdoor Wall Hoods)
NOTE: Optional duct cover sold separately.
VWHO 18”H. Outdoor Wall Hoods
Description
Duct cover width
Duct cover depth
Duct cover height
Number of lights
Number of filters
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
36”
48”
47-7/8” (121.6 cm)
12” (30.5 cm)
12” (30.5 cm)
3
60”
35-7/8” (91.1 cm)
59-7/8” (152.1 cm)
2
2
4
4
3
VINV1200*
DEV1200*/1500**
DIL1200
VINV1200*
DEV1200*/1500**
DIL1200
VINV1200*
DEV1200*/1500**
DIL1200
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
11.4
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from
the elements as much as possible.
9.0
6.1/6.8
7.9
11.8
8.8/9.5
10.6
8.4/9.1
10.2
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back
wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces, and a 24”
minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible
material used for this purpose must be covered with locally-supplied stainless steel. Viking also
recommends using a backsplash.
* A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when indoor models are
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”)
(VCWH Chimney Wall Hoods)
NOTE: Optional duct cover sold separately.
VCWH Chimney Wall Hoods
Description
30”
36”
42”
48”
54”
60”
66”
Duct cover width
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm)
Duct cover depth
Duct cover height
Number of lights
Number of filters
12” (30.5 cm)
12” (30.5 cm) to 24” (61.0 cm)
2
2
1
2
2
1
2
2
3
2
3
3
4
3
4
3
Heat lamps
1
2
2
2
2
VINV300/600 VINV300/600
VINV600
VINV1200*
VINV1200*
VINV1200*
VINV1200*
Interior ventilator kits
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DIL900/1200 DIL900/1200 DIL900/1200
DIL1200
DIL1200
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
7” (17.8 cm) 7” (17.8 cm)
7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
4.9/5.9
8.7/6.0
4.9/5.9
8.7/6.0
5.9
11.5
11.5
11.9
11.9
Interior—Maximum amps
Exterior—Maximum amps
8.7/6.0
8.5/9.2
8.5/9.2
8.5/9.2
8.5/9.2
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7
10.7
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VCWH Chimney Wall Hoods)
(VCWH Chimney Wall Hoods)
Top View
Top View
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36”, & 42” models
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42” models
Top View
Top View
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48”, 54”, 60”, & 66” models
1200 CFM Interior Ventilator Installation
for 48”, 54”, 60”, & 66” models
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(DCWH Classic Chimney Hoods)
(DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”)
DCWH Classic Chimney Wall Hoods
Description
30”
36”
42”
48”
Duct cover width
10” (25.4 cm)
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
Duct cover depth
Duct cover height
12” (30.5 cm)
18” (45.7 cm) to
30” (76.2 cm)
16” (40.6 cm) to
28” (71.1 cm)
16” (40.6 cm) to
28” (71.1 cm)
16” (40.6 cm) to
28” (71.1 cm)
Number of lights
2
2
2
3
3
3
Number of filters
2
2
VINV300/600
DEV900/1200*
VINV300/600
DEV900/1200*
VINV600
DEV900/1200*
VINV1200*
DEV1200*/1500**
Interior ventilator kits
Exterior ventilator kits
DIL900/1200
7” (17.8 cm)
DIL900/1200
7” (17.8 cm)
DIL900/1200
7” (17.8 cm)
DIL1200
In-line ventilator kits
Interior duct size
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
2.8/3.8
6.6/3.9
3.9/5.7
2.8/3.8
6.6/3.9
3.9/5.7
3.8
7.3
4.3/5.1
6.1
Interior—Maximum amps
NOTE: For best performance, it is recommended
that the bottom of the hood be 30” (76.2 cm) to
36” (91.4 cm) above the countertop. These dimensions
provide for safe and efficient operation of the hood.
6.6/3.9
3.9/5.7
Exterior—Maximum amps
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(DCWH Classic Chimney Hoods)
(DCWH Classic Chimney Hoods)
Top View
Top View
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42”Hoods
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36”, & 42” Hoods
Top View
Top View
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48” Hoods
1200 CFM Interior Ventilator Installation
for 48” Hoods
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
(VCIH Chimney Island Hoods)
NOTE: Optional duct cover sold separately.
VCIH Chimney Island Hoods
Description
36”
42”
54”
66”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
Duct cover depth
Duct cover height
Number of lights
Number of filters
12” (30.5 cm)
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
4
4
4
4
6
6
8
8
Heat lamps
N/A
VINV600
DEV900/1200*
DIL900/1200
7” (17.8 cm)
VINV600
DEV900/1200*/1500**
DIL900/1200
VINV1200*
DEV1200*/1500**
DIL1200
VINV1200*
DEV1200*/1500**
DIL1200
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
4.6
4.6
8.9
5.6/6.4
7.4
9.3
6.4/7.4
7.4
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
7.4/4.7
4.7/6.5
7.4/4.7/5.5
3.9/5.7
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VCIH Chimney Island Hoods)
(VCIH Chimney Island Hoods)
Top View
Top View
600 CFM Interior Ventilator Installation
for all Chimney Island Hoods
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
Top View
Top View
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
1200 CFM Interior Ventilator Installation
for all Chimney Island Hoods
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Hood Canopy
Dimensions & Specifications
(VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”)
(Custom Hood Canopy Cutouts)
Custom Hood
Canopy
Make sure the back wall
of the custom hood
canopy is flush with the
cutout so the ventilator
system may be mounted
as shown on page 25.
*For best results,
center the unit over
the burners of the
cooking product
(front to back; right
to left).
Bottom Cutout Dimensions
Wall Hoods
Description
30” W.
A (Hood Width)
27-7/16” (69.7 cm)
33-7/16” (84.9 cm)
39-7/16” (100.2 cm)
45-7/16” (115.4 cm)
51-7/16” (130.7 cm)
57-7/16” (145.9 cm)
63-7/16” (161.1 cm)
B (Hood Depth)
21-7/16” (54.5 cm)
36” W.
42” W.
48” W.
54” W.
60” W.
66” W.
21-7/16” (54.5 cm)
21-7/16” (54.5 cm)
21-7/16” (54.5 cm)
21-7/16” (54.5 cm)
21-7/16” (54.5 cm)
21-7/16” (54.5 cm)
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
Built-In Ventilator
System
VBCV Wall Custom Ventilator System
Description
Number of lights
Number of filters
Heat lamps
30”
36”
42”
48”
54”
60”
66”
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
2
2
1
2
2
1
2
2
1
3
3
2
3
3
2
4
4
2
4
4
2
VINV300/
600/1200*
VINV300/
600/1200*
VINV600/ VINV1200* VINV1200* VINV1200* VINV1200*
1200*
Interior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/ DEV1200*/ DEV1200*/ DEV1200*/
Exterior ventilator kits
3) OPTIONAL
1500**
1500**
1500**
1500**
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
DIL900/1200 DIL900/1200 DIL900/1200
DIL1200
DIL1200
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
7”/10”
7”/10”
7”/10”
10”
10”
10”
10”
(17.8/25.4 cm) (17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm)
Exterior duct size
10” (25.4 cm)
5.9/9.0
8.7/6.0
5.9/9.0
8.7/6.0
5.9/9.0
8.7/6.0
11.5
11.5
11.9
11.9
Interior—Maximum amps
Exterior—Maximum amps
8.5/9.2
8.5/9.2
8.9/9.2
8.9/9.2
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7
10.7
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
26
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Clearance Dimensions
Built-In Wall Custom Ventilator
(VBCV Wall Custom Ventilator System)
System Dimensions
(VBCV Models)
For 300, 600 or 1200 CFM Interior
Ventilator Installation
For 900, 1200 or 1500 CFM Exterior
or In-Line Ventilator Installation
900 or 1200 CFM Exterior
or In-Line Ventilator Installation
30”, 36”, 42” W. Models
300 or 600 CFM Interior
Ventilator Installation
30”, 36”, 42” W. Models
D
C
30” W.
36” W.
42” W.
14-1/8” (35.9 cm)
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
30” W.
36” W.
42” W.
28-1/4” (71.8 cm)
34-1/4” (87.0 cm)
40-1/4” (102.2 cm)
28
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning Information
Built-In Wall Custom Ventilator
System Dimensions
(VBCV Models)
Proper installation of ducting is extremely
important to ensure maximum performance
from any ventilation product.
• All CFMs are based on tests at 0.1 static
pressure: without applying static pressure, CFM
would be greatly overstated.
• Straight runs and gradual turns are best; for
example, each 90º elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.
• Never use flexible duct; it creates back pressure/air
turbulence and greatly reduces performance.
• Proper performance is dependent on proper
ducting; make sure that a qualified and trained
installer is used.
• Check with a qualified and trained installer or
local codes for makeup air requirement, if any.
• Max. amp rating for hoods includes
recommended ventilator kit rating; all products
must be hard wired direct with 2-wire with ground.
1200 or 1500 CFM Exterior or In-Line Ventilator Installation
48”, 54”, 60”, 66” W. Models
Plan where the duct work will be located. Install
proper-sized duct work, and roof or wall cap for the
type of blower you are using. Recommended hood
locations for the most common installations are
shown. Adjust your measurements for various heights
of ceilings, soffits, cabinets, or ranges/rangetops.
Check Framing
1200 CFM Interior Ventilator Installation
30”, 36”, 42”, 48”, 54”, 60”, 66” W. Models
C
D
30” W.
36” W.
42” W.
48” W.
54” W.
60” W.
66” W.
28-1/4” (71.8 cm)
34-1/4” (87.0 cm)
40-1/4” (102.2 cm)
46-1/4” (117.5 cm)
52-1/4” (132.7 cm)
58-1/4” (148.0 cm)
64-1/4” (163.2 cm)
30” W.
36” W.
42” W.
48” W.
54” W.
60” W.
66” W.
14-1/8” (35.9 cm)
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
23-1/8” (58.7 cm)
26-1/8” (66.4 cm)
29-1/8” (74.0 cm)
32-1/8” (81.6 cm)
NOTE: Because of the weight of the hood make sure
that the mounting screws are driven into the framing
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment.
30
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator)
Text goe here.
necessary.
Check damper for unrestricted movement, adjust if
Text goe here.
Attach transition to damper. Seal with aluminum tape.
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing. Use additional mounting
screws, if necessary.
provided. Use additional mounting screws and wall
anchors, if necessary.
W A R N I N G
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Flip hood over and remove electrical box cover.
Text goe here.
Text goe here.
Replace electrical box cover. Make connection to
breaker box.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Insert 6” of electrical wiring through the top of vent hood
Text goe here.
and secure using wiring restrain. Refer to local codes.
Slide duct over transition and tape around joint.
Text goe here.
32
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Attach with screws and lock washers provided.
Attach with screws.
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)
W A R N I N G
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
Remove electrical box cover.
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit)
Flip hood over. Insert 6” of electrical wiring through the
top of vent hood and secure. Refer to local codes.
screws are secured into framing. Use additional
mounting screws and wall anchors, if necessary.
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
34
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods)
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Replace electrical box cover. Make connection to
breaker box.
Measure down 1-13/16 (4.6 cm) from desired height of
hood and secure 1-1/2” x 3/4” wood strip (provided
locally) to wall using screws provided.
Use additional mounting screws to secure hood to
wood strip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing use additional mounting
screws, if necessary.
Assemble brackets to baffles and insert charcoal filters.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
36
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Duct Cover Option (VCWH Chimney Wall Hoods)
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Measure distance from ceiling to canopy.
Tape to avoid scratching.
Duct Cover Option (VWH 18”H. Wall Hoods)
Place duct cover top inside duct cover base and lower until
desired height is found. Mark height. Use the retaining
nuts and bolts to fasten in place and remove tape.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
38
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation (VCIH Island Hoods)
Run duct work down to bottom edge of duct
cover/soffit and secure in place. Make sure the duct
does not stick down past the cover.
Attach canopy to duct cover/soffit. Seal top of hood to
duct with aluminum tape.
Check framing where cutout will be.
Cut appropriate size hole in ceiling. Either 7” or 10”
depending on your specific unit and ventillator kit.
NOTE: 200 lb. limit.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Attach duct cover to optional ceiling mounting bracket.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip. NOTE: Number of spacers
and baffles may vary by model.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Attach duct cover to ceiling. The ceiling bracket can be
hidden by using a locally supplied trim.
Additional support option. Drill holes in all four corners
for threaded rod and run rods from hood to ceiling.
40
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation(DCWH Classic Chimney Wall Hoods)
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Measure down 1-13/16 (4.6 cm) from desired height of
hood and secure 1-1/2” x 3/4” wood strip (not
included) to wall using screws provided.
Use additional mounting screws to secure hood to
wood strip.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
CAUTION: Secure vent hood to wall using screws provided.
Make sure mounting screws are secured into frame. Use
additional mounting screws and wall anchors, if necessary.
CAUTION: If not using a duct cover, using screws provided
make sure top mounting screws are secured into soffit or
cabinet frame. Use additional mounting screws, if necessary.
Duct Cover Option (DCWH Classic Chimney Wall Hoods)
Measure distance from ceiling to canopy.
Tape to avoid scratching.
42
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Service & Registration
Wiring Diagram
Service & Parts
Only authorized replacement parts may be
used in performing service on the appliance.
Do not repair or replace any part of the
appliance unless specifically recommended in
the manual. All other servicing should be
referred to a qualified technician.
PROFESSIONAL BUILT-IN HOODS
Record the following information indicated
below. You will need it if service is ever required.
The serial number and model number for your
appliance are located on the identification plate
mounted on the inside of the hood canopy.
Model number
_________________________________________
Serial number
_________________________________________
Date of purchase
_________________________________________
Date installed
_________________________________________
Dealer's name
_________________________________________
Address
_________________________________________
44
45
Download from Www.Somanuals.com. All Manuals Search And Download.
46
47
Download from Www.Somanuals.com. All Manuals Search And Download.
|