TOA Electronics Fire Pit B 40REN User Manual

HOMEOWNER'S CARE AND  
OPERATION INSTRUCTIONS  
STANDARD SERIES  
36" B-VENTED GAS APPLIANCES  
P/N 725,008M REV. F 05/2004  
MODELS  
Millivolt Models  
B-40RMN  
B-40RMP  
Electronic Models  
B-40REN  
B-40REP  
RETAIN THESE INSTRUCTIONS  
FOR FUTURE REFERENCE  
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE  
LESINSTRUCTIONSDONNÉDANSCETTENOTICEPOUR  
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU  
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE  
BLESSURE OU LA MORT.  
WH Report No. J20006722  
WARNING:IFTHEINFORMATIONINTHISMANUAL  
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-  
SION MAY RESULT CAUSING PROPERTY DAM-  
AGE, PERSONAL INJURY OR LOSS OF LIFE.  
POURVOTRESÉCURITÉ: Nepasentreposerniutiliser  
d'essencenid'autrevapeursouliquidesinflammables  
dans le voisinage de cet appareil ou de tout autre  
appareil.  
FOR YOUR SAFETY: Do not store or use gasoline  
or other flammable vapors or liquids in the vicin-  
ity of this or any other appliance.  
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une  
odeur de gaz:  
FOR YOUR SAFETY: What to do if you smell gas:  
• Ne pas tenter d'allumer d'appareil.  
• Netouchezàaucuninterrupteur. Nepasvousservir  
des téléphones se trouvant dans le batiment où  
vous vous trouvez.  
• Evacuez la piéce, le bâtiment ou la zone.  
• Appelez immédiatement votre fournisseur de gaz  
depuis un voisin. Suivez les instructions du  
fournisseur.  
• DO NOT light any appliance.  
• DO NOT touch any electrical switches.  
• DO NOT use any phone in your building.  
• Immediately call your gas supplier from a  
neighbor’s phone.  
Follow your gas suppliers instructions.  
• Ifyourgassuppliercannotbereached, callthe  
fire department.  
• Si vous ne pouvez rejoindre le fournisseur de gaz,  
appelez le service dos incendies.  
Installation and service must be performed by a  
qualified installer, service agency or the gas  
supplier.  
L'installationetservicedoitêtreexécutéparunqualifié  
installeur, agence de service ou le fournisseur de gaz.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Millivolt appliances may be fitted at time of  
manufacture with either a Honeywell millivolt  
gas control valve or as SIT millivolt gas control  
valve. Both valves have been tested with and  
approved for use with these appliances and  
are listed accordingly.  
Carbon Monoxide Poisoning: Early signs of  
carbon monoxide poisoning are similar to  
thefluwithheadaches,dizzinessand/ornau-  
sea. If you have these signs, obtain fresh air  
immediately. Turn off the gas supply to the  
appliance and have it serviced by a qualified  
professional, as it may not be operating  
correctly.  
Gas Controls  
on Valve  
Test gage connections are provided on the  
front of the millivolt gas control valve (iden-  
tified IN for the inlet and OUT for the mani-  
fold side). A ¹⁄₈" NPT test gage connection is  
provided at the inlet and outlet side of  
the electronic gas control valve.  
WARNING: B-VENT APPLIANCES ARE  
NOT DESIGNED TO OPERATE IN NEGA-  
TIVELY PRESSURED ENVIRONMENTS  
(PRESSURE WITHIN THE HOME IS LESS  
THAN PRESSURES OUTSIDE). SIGNIFI-  
CANT NEGATIVELY PRESSURED ENVI-  
RONMENTS CAUSED BY WEATHER,  
HOMEDESIGN,OROTHERDEVICESMAY  
IMPACT THE OPERATION OF THESE AP-  
PLIANCES. NEGATIVEPRESSURESMAY  
RESULTINPOORFLAMEAPPEARANCE,  
SOOTING,DAMAGETOPROPERTYAND/  
ORSEVEREPERSONALINJURY.DONOT  
OPERATE THESE APPLIANCES IN NEGA-  
TIVELY PRESSURED ENVIRONMENTS.  
Removable  
Access Panel  
SIT Valve Shown  
Minimum inlet gas pressure to the appliance is  
5.0 inches water column (1.24 kPa) for natural  
gas and 11 inches water column (2.74 kPa) for  
propane for the purpose of input adjustment.  
Figure 1  
Operationofmillivoltandelectronicgascontrol  
systems are different. Before lighting and op-  
erating your appliance determine if you have a  
millivoltorelectronicappliance. RefertoFigure  
1 to access the gas control compartment. Mil-  
livolt appliances will be fitted with one of the  
two gas control valves shown in Figure 2.  
Maximum inlet gas supply pressure to the  
appliance is 10.5 inches water column (2.61  
kPa) for natural gas and 13.0 inches water  
column (3.23 kPa) for propane.  
The appliance must be isolated from the gas  
supply piping system (by closing its individual  
manual shut-off valve) during any pressure test-  
ing of the gas supply piping system at test  
pressures equal to or less than ¹⁄₂ psig (3.5 kPa).  
Appliances with electronic systems will be fit-  
ted with the electronic valve shown in Figure 3.  
Familiarize yourself with the differing controls  
for the valve your appliance uses.  
WARNING: CHILDREN AND ADULTS  
SHOULD BE ALERTED TO THE HAZ-  
ARDS OF HIGH SURFACE TEMPERA-  
TURES. USE CAUTION AROUND THE  
APPLIANCE TO AVOID BURNS OR  
CLOTHING IGNITION. YOUNG CHIL-  
DRENSHOULDBECAREFULLYSUPER-  
VISED WHEN THEY ARE IN THE SAME  
ROOM AS THE APPLIANCE.  
To light millivolt appliances refer to the detailed  
lighting instructions found in both English and  
French on pages 10 and 11 of these instruc-  
tions respectively. Millivolt and electronic  
appliance lighting instructions may also be  
found on the pull out labels attached to the  
gas control valve located within the gas con-  
trol compartment. See Figure 2 to locate the  
appropriate location for the spark ignitor used  
with your appliance.  
The appliance and its individual shut-off valve  
must be disconnected from the gas supply  
piping system during any pressure testing of  
that system at pressures in excess of ¹⁄₂ psig  
(3.5 kPa).  
These appliances must not be connected to a  
chimney or flue serving a separate solid fuel  
burning appliance.  
WARNING: DO NOT PLACE CLOTH-  
ING OR OTHER FLAMMABLE MATE-  
RIALS ON OR NEAR THIS APPLIANCE.  
WARNING: FAILURE TO COMPLY WITH  
THEINSTALLATIONANDOPERATINGIN-  
STRUCTIONS PROVIDED IN THIS DOCU-  
MENT WILL RESULT IN AN IMPROP-  
ERLY INSTALLED AND OPERATING AP-  
PLIANCE,VOIDINGITSWARRANTY. ANY  
CHANGE TO THIS APPLIANCE AND/OR  
ITSOPERATINGCONTROLSISDANGER-  
OUS. IMPROPERINSTALLATIONORUSE  
OF THIS APPLIANCE CAN CAUSE SERI-  
OUS INJURY OR DEATH FORM FIRE,  
BURNS, EXPLOSION OR CARBON MON-  
OXIDE POISONING.  
If your appliance is equipped with an optional  
remote wall switch or remote control kit the  
appliancemainburnermaybeturnedonandoff  
with the wall switch or remote control. If the  
appliance is not equipped with a wall or remote  
control, themainburnermustbeturnedoffand  
on with the gas control knob. Turn the knob  
counter-clockwise from the PILOT position to  
ONtolightthemainburner,andclockwisefrom  
ON to PILOT to turn off the main burner.  
AVERTISSEMENT: SURVEILLER LES  
ENFANTS. GARDER LES VÊTEMENTS,  
LESMEUBLES,L'ESSENCEOUAUTRES  
LIQUIDES À VAPEUR INFLAMMABLES  
LOIN DE L'APPAREIL.  
OPERATION AND CARE OF YOUR  
APPLIANCE  
To light electronic appliances refer to the de-  
tailed lighting instructions found in both En-  
glish and French on pages 12 and 13 of these  
instructions respectively. Millivolt and elec-  
tronicappliancelightinginstructionsmayalso  
be found on the pull out labels attached to the  
gas valve located within the gas control com-  
partment. Ifyourapplianceisequippedwithan  
optional remote wall switch or remote control  
kit the appliance main burner may be turner on  
and off with the wall switch or remote control.  
1. Appliance operation may be controlled  
througharemotelylocatedoptionalwallswitch.  
Separate switches may provide independent  
control for the remote controlled fireplace op-  
eration (optional equipment). In lieu of remote  
or remote wall switch operation, the appliance  
must be operated directly through the controls  
located on the front of the valve located within  
the control compartment under the removable  
access panel, Figure 1.  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
T
L
WARNING: FIREPLACES EQUIPPED  
WITH OPTIONAL ACCESSORY DOORS  
SHOULD BE OPERATED ONLY WITH  
THE DOORS FULLY OPEN OR FULLY  
CLOSED (FIGURE 4 ). THIS APPLI-  
ANCE MAY ONLY BE FITTED WITH  
DOORS CERTIFIED FOR USE WITH  
THE APPLIANCE.  
N
T
O
P
O
IN  
OUT  
SIT Millivolt Valve  
Spark Ignitor  
Gas Control Knob  
Spark Ignitor  
AVERTISSEMENT: POUR UTILISATION  
UNIQUEMENT AVEC LES PORTES EN  
VERRE CERTIFIÊES AVEC L'APPAREIL.  
Gas Control Knob  
O
I
L
O
O
T
Honeywell Millivolt Valve  
Figure 2  
4. Always turn off gas to the pilot (millivolt  
appliances) before cleaning. Before re-light-  
ing, refer to the lighting instructions in this  
manual. Instructions are also found on a pull-  
out panel located on the floor of the appliance.  
Fully Open or  
Fully Closed  
ON/OFF Switch  
Manifold Pressure Port  
Figure 4  
Inlet  
Pressure  
Port  
COMBUSTION AIR CONTROLS  
5.Alwayskeeptheapplianceareaclearandfree  
fromcombustiblematerials,gasolineandother  
flammable liquids.  
Many appliances are equipped when installed  
with an outside combustion air vent system  
that is designed to provide the appliance with  
outside make-up air for combustion when in  
operation.  
Electronic  
Gas Control  
Valve  
6. Remember, Millivolt appliances have a con-  
tinuous burning pilot flame. Exercise caution  
when using products with combustible vapors.  
Honeywell Electronic  
Gas Valve  
Figure 3  
7. Clean the optional glass doors only when  
necessary. Wipe surface with clean, damp-  
ened, soft cloth. Follow with dry, soft towel as  
desired. Take care not to scratch the glass  
surface.  
If the appliance is not equipped with a wall  
switchorremotecontrol, themainburnermust  
be turned off and on with the gas control  
switch. Toggle the switch from ON to OFF to  
operate the main burner from ON to OFF.  
Combustion  
Air Actuator  
WARNING: DO NOT USE ABRASIVE  
CLEANERS. NEVERCLEANTHEGLASS  
WHEN IT IS HOT.  
2. When lit for the first time, this appliance will  
emit a slight odor for an hour or two. This is  
due to the burn-inof internal paints and  
lubricants used in the manufacturing process.  
CAUTION: DO NOT ATTEMPT TO TOUCH THE  
DOORSWITHYOURHANDSWHILETHEFIRE-  
PLACE IS IN USE. ALWAYS USE DOOR  
HANDLES. DOORS WILL BECOME VERY HOT  
WHEN FIREPLACE IS IN USE.  
Figure 5  
3. Keep lower control compartment clean by  
vacuuming or brushing at least twice a year.  
Morefrequentcleaningmayberequireddueto  
excessive lint from carpeting, bedding materi-  
als, etc. It is important that control compart-  
ments, burners and circulating air passage-  
ways of the appliance be kept clean.  
The actuator for combustion air system is  
standard on all appliances but must not be  
operated if the complete system is not in-  
stalled. Refer to Figures 5 and 6. When the  
complete outside combustion air vent system  
is installed, the installer will remove the actua-  
tor locking screw.  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Combustion Air  
Actuator  
Manual  
Reset  
Limit  
Remove Locking Screw  
and “Pop” Actuator to the  
Left Before Initial Use  
Limit  
Switch  
Bracket  
Switch  
Lintel Extension  
Bracket Screw  
Maintenance  
Pull Forward to Open,  
Push Back to Close  
Figure 7  
Figure 6  
MANUALLY-RESET BLOCKED FLUE SAFETY  
SWITCH  
If your screw is not removed and you have  
reason to believe that you have a complete  
outside combustion system, contact your dis-  
tributor to have your appliance inspected for  
the presence of the complete system. DO NOT  
assume that you have this system in place  
because you have an actuating lever present  
on your appliance front face.  
The appliance and venting system should be  
thoroughly inspected before initial use and at  
least annually by a qualified service techni-  
cian. Proper maintenance and use will require  
more frequent, less extensive inspections and  
servicing by the homeowner.  
This appliance is equipped with a manually-  
reset blocked flue safety switch. Refer to  
Figure 7 for its location. If during appliance  
operation, the flame goes out (independently  
of the burner on/off wall switch), it may be due  
totheoperationofthissafetylimitswitch. First  
allow the appliance to cool. Then reset the  
safety switch by pushing the red reset button  
on the back of the switch.  
Generally, annual inspections should be per-  
formedbyaqualifiedservicetechnician. More  
frequent periodic inspections and cleanings  
should be performed by the homeowner. Any  
discrepancies discovered by the homeowner  
should result in a call to a qualified service  
technician to effect the repair or correction.  
WARNING: DO NOT OPERATE THE  
COMBUSTIONAIRACTUATORUNLESS  
A COMPLETE OUTSIDE COMBUSTION  
AIR VENT SYSTEM HAS BEEN IN-  
STALLED WITH YOUR APPLIANCE.  
To access the blocked flue safety switch, re-  
move the limit switch bracket, with switch and  
low voltage wires attached. Push the red reset  
button and then reinstall limit switch bracket.  
To provide outside combustion air to your  
appliance while it is in operation, locate the  
combustion air actuator along the right side of  
the appliance opening (refer to Figure 5 ).  
Refer to the maintenance schedule for mainte-  
nance tasks, procedures, periodicity and by  
whom they should be performed.  
The appliance should then relight and remain  
lit. If this does not occur, turn off the appli-  
ance and call a qualified service technician.  
To operate, push the end of the actuator to the  
left as shown in Figure 6, until it "pops" free of  
its "locked" position. Pull the actuator forward  
to open the combustion air door, and push it  
back to close.  
IMPORTANT: TURN OFF GAS AND ANY  
ELECTRICAL POWER BEFORE SERVICING  
THE APPLIANCE.  
To "lock" the combustion air door closed, en-  
sure the actuator is pushed all the way back,  
then push the end of the actuators to the right  
until the step in the actuator moves behind the  
appliance front face within the slotted opening.  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Millivolt Appliance Checkout  
The pilot flame should be steady, not lifting or  
floating. Flame should be blue in color with  
traces of orange at the outer edge.  
The top ³⁄₈" (9 mm) at the pilot generator (ther-  
mopile) should be engulfed in the pilot flame.  
The flame should project 1" (25 mm) beyond  
the hood at all three ports (Figure 8 ).  
Electronic Appliance Checkout  
Light the burner, refer to the Lightilng Instruc-  
tions in this manual. Ensure the ignitor lights  
the pilot. The pilot flame should engulf the  
flame rod as shown in Figure 8.  
Figure 9  
These appliances are fitted with a pair of deco-  
rative non-combustible concrete logs that are  
wired in place on the log grate at the factory.  
Normally these logs never have to be reposi-  
tioned. Occasionally they may be removed for  
cleaning, or just the front log may be removed  
to provide greater access to the pilot assembly  
and the control compartment below.  
Log Placement  
With proper care and maintenance, your appli-  
ancewillprovidemanyyearsofenjoyment.Ifyou  
should experience any problem, first refer to the  
troubleshootingguideinthismanual. Ifproblem  
persists, contact your Superior distributor.  
WARNING: LOGS GET VERY HOT AND  
WILL REMAIN HOT UP TO ONE HOUR  
AFTER GAS SUPPLY IS TURNED OFF.  
HANDLE ONLY WHEN LOGS ARE COOL.  
TURN OFF ALL ELECTRICITY TO THE  
APPLIANCE BEFORE YOU INSTALL  
GRATE AND LOGS.  
MILLIVOLT  
Hood  
Ignitor Rod  
³⁄₈" Min  
(9 mm)  
To remove the logs, untie the wires securing he  
logs to the grate. These wires are only required  
for shipping and should be completely cut  
awaybeforerepositioningthelogsonthegrate.  
Refer to Figure 9 for log placement. Align the  
rear log with the slots on its bottom engaging  
the grate tines. Position the front log, centered  
on the grate and with the rear log behind it.  
WARNING: THIS APPLIANCE IS NOT  
MEANT TO BURN WOOD. ANY AT-  
TEMPT TO DO SO COULD CAUSE IR-  
REPARABLE DAMAGE TO YOUR APPLI-  
ANCE AND PROVE HAZARDOUS TO  
YOUR SAFETY.  
Thermopile  
Pilot  
Nozzels  
Decorative volcanic stone is available to en-  
hance the look of the fireplace presentation.  
Decorative volcanic stone should be spread  
evenly through non-uniformly over the entire  
bottom surface of the firebox to provide the  
look of an ember bed.  
ELECTRONIC  
3/8 To 1/2 Inch  
(9 mm to 13 mm)  
WARNING: THE SIZE AND POSITION ON  
THELOGSETWASENGINEEREDTOGIVE  
YOUR APPLIANCE A SAFE, RELIABLE  
ANDATTRACTIVEFLAMEPATTERN. ANY  
ATTEMPT TO USE A DIFFERENT LOG  
SET IN THE FIREPLACE WILL VOID THE  
WARRANTY AND WILL RESULT IN IN-  
COMPLETE COMBUSTION, SOOTING,  
AND POOR FLAME QUALITY.  
Proper Flame  
Adjustment  
Pilot  
Nozzle  
Ground  
Electrode  
Flame  
Sensor  
Hot Surface  
Igniter  
Figure 8  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance Schedule  
Annually (Before the onset of the Burning Season)  
Maintenance Task  
Accomplishing Person  
Procedure  
Inspecting/Cleaning Burner, Logs  
and Controls  
Qualified Service Technician  
Inspect valve and ensure it is properly operat-  
ing. Check piping for leaks. Vacuum the  
controlcompartment,fireplacelogsandburner  
area.  
Check Flame Patterns and Flame Height  
Inspecting/Cleaning Pilot and Burner  
Qualified Service Technician  
Qualified Service Technician  
Refer to Figure 9 and verify the flame pattern  
and height displayed by the appliance con-  
formstothepicture. Flamesmustnotimpinge  
on the logs.  
Refer to Figure 8. Remove any surface build-  
up on pilot and burner assembly. Wipe the  
pilot nozzles, ignitor/flame rod and hood. En-  
surethepilotflameengulfstheflamesensoras  
shown.  
Checking Vent System  
Appliance Checkout  
Qualified Service Technician  
Qualified Service Technician  
Inspect the vent system at the top and at the  
base (within the firebox) for signs of blockage  
or obstruction. Look for any signs of disloca-  
tion of the vent components.  
Perform the appropriate appliance checkout  
procedure detailed in this manual.  
Periodically (After the Burning Season)  
Maintenance Task  
Accomplishing Person  
Procedure  
Cleaning Firebox Interior  
Homeowner  
Carefully remove logs and volcanic stone if  
used. Vacuum out interior of the firebox.  
Clean firebox walls and log grate. Replace  
logs and volcanic stone as detailed in this  
manual.  
Check Flame Patterns and Flame Height  
Checking Vent System  
Homeowner  
Homeowner  
Homeowner  
Refer to Figure 9 and verify the flame pattern  
and height displayed by the appliance con-  
formstothepicture. Flamesmustnotimpinge  
on the logs.  
Inspect the vent system at the top and at the  
base (within the firebox) for signs of blockage  
or obstruction. Look for any signs of disloca-  
tion of the vent components.  
Cleaning Optional Glass Doors  
Clean as necessary following the directions  
provided in this manual. DO NOT TOUCH OR  
ATTEMPT TO CLEAN DOORS WHILE THEY  
ARE HOT.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAMS  
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics found on pullout labels attached  
to the gas valve located within the control compartment. Two Millivolt wiring diagrams are provided here, one each for both Honeywell and SIT  
equipped systems.  
Honeywell Millivolt Wiring Diagram  
Electronic Wiring Diagram (Honeywell)  
(Optional ON/OFF Switch Wiring)  
SIT Millivolt Wiring Diagram  
If any of the original wire as supplied must be replaced,  
it must be replaced with Type AWM 105°C – 18 GA. wire.  
If any of the original wire as supplied must be replaced, it  
must be replaced with Type AWM 105°C – 18 GA. wire.  
1. If any of the original wire as supplied must be replaced,  
1. it must be replaced with Type AWM 105°C – 18 GA.  
wire.  
BK  
WHT  
T H  
2. 120V, 60Hz – Less than 3 amps.  
Limit Switch  
BK  
Gas Valve  
CONTROL  
OPT. ACCESSORY  
SWITCH  
PILOT  
ASSEMBLY  
BK  
BK  
T H  
TPTH  
BK  
120  
VAC.  
BK  
TP  
W
G
Limit  
Switch  
R
BL  
G
Thermopile  
BK  
Break  
Off Tab  
TH  
TP  
TP  
To Opposite Side  
WHT  
Junction Box  
Thermopile  
W
* For Wall Switch Attachment Only.  
BK  
Transf.  
120 V.  
B
G
* For Wall Switch Attachment Only.  
24 V  
BL  
R
BK  
BK  
WHT  
BK  
BK  
OPTIONAL  
LIMIT  
SWITCH  
ON/OFF SWITCH  
OR  
WALL SWITCH  
Field Wired  
Factory Wired  
When ordering repair parts, always give the  
following information:  
REPLACEMENT PARTS  
WARRANTY  
Yourgasapplianceiscoveredbyalimitedtwenty  
yearwarranty.Youwillfindacopyofthewarranty  
accompanying this manual. Please read the  
warranty to be familiar with its coverage.  
A complete parts list is found at the end of this  
manual. Use only parts supplied from the  
manufacturer.  
1. The model number of the appliance.  
2. The serial number of the appliance.  
3. The part number.  
4. The description of the part.  
5. The quantity required.  
Normally, all parts should be ordered through  
your Lennox distributor or dealer. Parts will be  
shipped at prevailing prices at time of order.  
Retain this manual. File it with your other  
documents for future reference.  
6. The installation date of the appliance.  
If you encounter any problems or have any  
questions concerning the installation or appli-  
cation of this system, please contact your dis-  
tributor. For the name of your nearest distribu-  
tor contact:  
PRODUCT REFERENCE INFORMATION  
We recommend that you record the following important information about your fireplace. Please  
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox  
dealer, please call 800-731-8101  
LHP  
Your Fireplace's Model Number _______________________________________  
Your Fireplace's Serial Number ________________________________________  
The Date On Which Your Fireplace Was Installed __________________________  
The Type of Gas Your Fireplace Uses ___________________________________  
Your Dealer's Name_________________________________________________  
1110 West Taft Avenue • Orange, CA  
92865  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION  
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  
A. This appliance has a pilot which must be lighted with a piezo  
ignitor. When lighting the pilot, follow these instructions  
exactly.  
Do not use any phone in your building.  
Immediately call your gas supplier from a neighbors phone.  
If your gas supplier cannot be reached, call the fire depart-  
ment.  
B. BEFORE OPERATING smell all around the appliance area for  
gas. Be sure to smell next to the floor because some gas is  
heavier than air and will settle on the floor.  
C. Use only your hand to push in or turn the gas control knob.  
Never use tools. If the knob will not push in or turn by hand,  
do not try to repair it, call a qualified service technician.  
Force or attempted repair may result in a fire or an explosion.  
WHAT TO DO IF YOU SMELL GAS  
Extinguish any open flame.  
Open windows.  
Do not light any appliance.  
Do not touch any electrical switches.  
D. Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect the  
appliance and to replace any part of the control system and  
any gas control which has been under water.  
LIGHTING INSTRUCTIONS  
1. STOP! Read the safety information above on this page.  
2. Access the lower control compartment.  
3. Turn remote wall switch to OFF.”  
6. Wait five (5) minutes to clear out any gas. If you then smell gas,  
STOP! Follow Bin the safety information above on this page. If you  
do not smell gas, go to the next step.  
7. Push in gas control knob slightly and turn counterclockwise  
to PILOT.”  
4. Verify main line shut-off valve is open.  
8. Push in control knob all the way and hold in. Immediately light the  
pilot by triggering the spark ignitor (pushing the button) until pilot  
lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes  
after the pilot is lit. Release knob and it will pop back up. Pilot should  
remain lit. If it goes out, repeat steps 5  
5. Push in gas control knob slightly and turn clockwise  
to OFF.”  
through 8.  
HONEYWELL  
SIT  
O
N
MILLIVOLT PILOT  
MILLIVOLT  
GAS VALVE  
I P  
If knob does not pop up when  
released, stop and immediately call  
your service technician or gas  
supplier.  
L
O
O
F
F
T
I N  
O U T  
If pilot will not stay lit after several  
tries, turn the control knob to OFF”  
and call your service technician or  
gas supplier.  
SIT  
MILLIVOLT  
GAS VALVE  
H
F
O
O
L
W
O
N
I
L
T O  
9. Turn gas control knob counterclockwise  
to ON.”  
Note: Knob cannot be turned from PILOTto OFF”  
10. Close lower control compartment.  
unless the knob is pushed in slightly. Do not force.  
TO TURN OFF GAS TO APPLIANCE  
1. Turn remote wall switch OFF.The pilot will remain lit for  
4. Depress gas control knob slightly and turn clockwise  
normal service.  
to OFF.Do not force.  
2. For complete shutdown, turn remote wall switch to OFF.”  
5. Close lower control compartment.  
3. Access the lower control compartment.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE  
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
A. Cet appareil est muni dune veilleuse qui doit être allumée avec un  
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre  
exactement ces instructions.  
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune  
odeur de gaz autour de lapareil ainsi que près du sol; certains gaz,  
étant plus lourds que lair, descendent au niveau du sol.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR  
DE GAZ:  
Appelez immédiatement votre compagnie de gaz en utilisant le  
téléphone du voisin.  
Sil vous est impossible de contacter votre compagnie de gaz, appelez  
le service des incendies.  
C. Nutilisez que votre main pour manipuler le bouton de réglage du gaz.  
Nutilisez jamais doutils. Si le bouton refuse de tourner ou de  
bouger, nessayez pas de le réparer. Communiquez immédiatement  
avec un technicien de service qualifié. Toute tentative pour le forcer  
ou le réparer, risquerait de provoquer un incendie ou une explosion.  
D. Ne vous servez pas de cet appareil si lun de ses éléments a été  
immergé dans leau. Appelez immédiatement un technicien compétent  
pour faire inspecter lappareil et remplacer toute pièce du système de  
réglage ou commande du gaz qui a été sous leau.  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
Nallumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez daucun téléphone dans votre édifice.  
INSTRUCTIONS D'ALLUMAGE  
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.  
2. Ouvrez le compartiment de contrôle du bas.  
8. Enfoncez le bouton de réglage jusquau fond et gardez-le enfoncé.  
Allumez immédiatement la veilleuse en déclenchant lallume-gaz à  
étincelle (en poussant le bouton) jusqu’à ce que la veilleuse  
senflamme. Continuez de tenir le bouton de réglage enfoncé  
pendant environ 90 secondes après lallumage de la veilleuse.  
Relâchez le bouton et il sortira subitement. La veilleuse devrait  
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8  
inclusivement.  
3. Tournez linterrupteur mural à la position darrêt OFF.  
4. Assurez-vous que la soupape darrêt de la canalisation principale est  
ouverte.  
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
le sens des aiguilles dune montre  
darrêt OFF.  
jusqu’à la position  
Si le bouton ne sort pas automatiquement après avoir été  
relâché, arrêtez immédiatement et téléphonez à votre technicien  
de service ou à votre fournisseur de gaz.  
VANNE GAZ  
MILLIVOLT  
HONEYWELL  
O
N
I P  
L
O
O
F
F
T
Si la veilleuse refuse de rester  
allumée après plusieurs tentatives,  
tournez le bouton de réglage jusqu’à  
sa position darrêt OFFet  
téléphonez à votre technicien de  
service ou à votre fournisseur de  
gaz.  
SIT  
MILLIVOLT PILOT  
I N  
O U T  
H
VANNE GAZ  
MILLIVOLT SIT  
F
O
O
L
W
O
N
I
L
T O  
9. Tournez le bouton de réglage du gaz  
en sens inverse des aiguilles dune  
montre  
jusqu’à sa  
position de marche ON.  
Remarque: Il est impossible de tourner le bouton de PILOT” à “OFF” à  
moins quil ne soit légèrement enfoncé. Ne le forcez pas.  
10. Fermez le compartiment de contrôle du bas.  
6. Attendez cinq (5) minutes pour levacuation du gaz. Si vous décelez  
une odeur de gaz, ARRÊTEZ ! Retournez au point Bdes  
consignes de sécurité au verso de cette plaque. Si vous ne  
remarquez aucune odeur de gaz, passez à l’étape suivante.  
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en  
sens inverse des aiguilles dune montre jusqu’à la position de  
11. Au besoin, rebrancher lappareil au courant électrique et remettre  
linterrupteur du brûleur principal à la position ONou régler le  
thermostat à la température désirée.  
12. Si lappareil ne fonctionne pas, suivre les instructions intitulées  
Pour fermer le gaz qui alimente lappareilet appeler un  
technicien ou le fournisseur de gaz.  
veilleuse  
PILOT.  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Tournez linterrupteur mural à la position darrêt OFF. La veilleuse  
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
restera allumée jusquau retour du service normal.  
le sens des aiguilles dune montre  
jusqu’à la position  
darrêt OFF. Ne forcez pas le bouton.  
2. Pour une fermeture complète, tournez linterrupteur mural à la  
position darrêt OFF.  
5. Fermez le compartiment de contrôle du bas.  
3. Ouvrez le compartiment de contrôle du bas.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS — ELECTRONIC  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION  
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  
A. When lighting the appliance, follow these instructions  
Immediately call your gas supplier from a neighbors  
exactly.  
phone.  
If your gas supplier cannot be reached, call the fire  
B. BEFORE OPERATING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
department.  
C. Use only your hand to turn the gas control lever. Never  
use tools. If the lever will not turn by hand, do not try to  
repair it, call a qualified service technician. Force or  
attempted repair may result in a fire or an explosion.  
WHAT TO DO IF YOU SMELL GAS  
Extinguish any open flame.  
Open windows.  
D. Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician to  
inspect the appliance and to replace any part of the  
control system and any gas control which has been  
under water.  
Do not light any appliance.  
Do not touch any electrical switches.  
Do not use any phone in your building.  
LIGHTING INSTRUCTIONS  
1. STOP! Read the safety information above on this page.  
2. Turn remote wall switch to OFF.”  
5. Turn the ON/OFF switch to OFF. Do not force.  
6. Wait five (5) minutes to clear out any gas. If you then  
smell gas, STOP! Follow Bin the safety information  
above on this page. If you do not smell gas, go to the  
next step.  
3. Open lower control compartment door.  
4. Verify main line shut-off valve is open.  
7. Turn the ON/OFF switch to ON. Do not force.  
ON/OFF Switch  
8. Turn ONall electrical power to appliance (remote wall  
switch).  
9. Close lower control compartment door.  
TO SHUT OFF  
1. Turn off all electrical power to the appliance (remote wall  
Front View  
switch).  
TO TURN OFF GAS TO APPLIANCE  
1. For complete shut-down, turn remote wall switch to  
3. Turn the ON/OFF switch to OFF. Do not force.  
4. Close the main line shut-off valve.  
OFF.”  
2. Open lower control compartment door.  
5. Close lower control compartment door.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU  
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
A. Lorsquevousallumezlappareil,suivezexactementcesinstruc-  
Appelez immédiatement votre compagnie de gaz en utilisant  
le téléphone du voisin.  
tions.  
Sil vous est impossible de contacter votre compagnie de  
gaz, appelez le service des incendies.  
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez  
aucune odeur de gaz autour de lapareil ainsi que près du sol;  
certainsgaz,étantpluslourdsquelair,descendentauniveaudu  
sol.  
C. Nutilisez que votre main pour manipuler linterrupteur ON/  
OFFde la valve à gaz. Nutilisez jamais doutils. Si  
linterrupteur ne bouge pas manuellement, nessayez pas de le  
réparer. Communiquez immèdiatement avec un technicien de  
service qualifié. Toute tentative pour forcer linterrupteur ou le  
réparer, risquerait de provoquer un incendie ou une explosion.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE  
ODEUR DE GAZ  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
D. Ne vous servez pas de cet appareil si lun de ses éléments a été  
immergé dans leau. Appelez immédiatement un technicien  
compétent pour faire inspecter lappareil et remplacer toute  
piècedusystèmederéglageoucommandedugazquiaétésous  
leau.  
Nallumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez daucun téléphone dans votre édifice.  
INSTRUCTIONS D’ALLUMAGE  
6. Attendez cinq (5) minutes pour levacuation du gaz. Si vous  
décelez une odeur de gaz ARRÊTEZ ! Retournez au point Bdes  
consignes de sécurité au verso de cette plaque. Si vous ne  
remarquez aucune odeur de gaz, passez à l’étape suivante.  
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette  
plaque.  
2. Tournez linterrupteur mural à la position darrêt OFF.  
7. Tournezlamanettederéglagedugazjusquàlapositiondemarche  
3. Ouvrez la porte du compartiment de contrôle du bas.  
ON. Ne la forcez pas.  
4. Assurez-vousquelasoupapedarrêtdelacanalisationprincipale  
8. Ouvrez le courant électrique (ON) qui alimente lappareil  
est ouverte.  
(interrupteur mural).  
9. Fermez la porte du compartiment de contrôle du bas.  
5. TournezlamanettederéglagedugazàlapositiondarrêtOFF.  
10. Au besoin, rebrancher lapareil au courant électrique et  
remettre linterrupteur principal du brûleur à la position ON”  
ou régler le thermostat à la température désirée.  
Interrupteur  
ON/OFF  
11. Si lappareil ne se met pas en marche, suivre les instructions  
intitulées Pour fermer le gaz qui alimente lappareilet appeler  
un technicien ou le fournisseur de gaz.  
POUR ÉTEINDRE L’APPAREIL  
1. Coupeztoutlecourantélectriquequialimentelappareil(interrupteur  
Vue de face  
mural).  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Pour une fermeture complète, tournez linterrupteur mural à la  
3. Tournez la manette de réglage du gaz à la position darrêt OFF.  
position darrêt OFF.  
Ne la forcez pas.  
2. Ouvrez la porte du compartiment de contrôle du bas.  
4. Fermez la soupape darrêt de la canalisation principale.  
5. Fermez la porte du compartiment de contrôle du bas.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM  
Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in  
the ONposition.  
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.  
SYMPTOM  
POSSIBLE CAUSES  
CORRECTIVE ACTION  
1. Spark ignitor will not light  
pilot after repeated  
A. Defective ignitor  
Check for spark at electrode and pilot; if no spark and  
electrode wire is properly connected, replace ignitor.  
(no spark at electrode).  
triggering of ignitor button.  
B. Defective or misaligned electrode  
Using a match, light pilot. If pilot lights, turn off pilot and  
trigger the ignitor button again. If pilot lights, an improper  
gas mixture caused the bad lighting and a longer purge  
period is recommended. If pilot will not light check gap at  
electrode and pilot - should be ¹⁄₈" to have a strong spark. If  
gap measures ¹⁄₈", replace pilot (Figure 8 on page 6 ).  
at pilot (spark at electrode).  
C. Gas supply pressure errant.  
Check inlet gas pressure. It should be within the limits as  
marked on the rating plate.  
D. Pilot orifice plugged.  
Clean or replace pilot orifice.  
2. Pilot will not stay lit after  
carefully following the  
lighting instructions.  
A. Defective pilot generator  
Check pilot flame, it must impinge on thermogenerator  
(Figure 8 on page 6 ). Clean and/or adjust pilot for maxi-  
mum flame impingement on thermogenerator. Ensure that  
the connection between the valve and thermogenerator are  
tight and secure.  
(thermogenerator).  
3. Pilot burning, no gas to  
burner, Valve knob ON,”  
Wall Switch ON.”  
A. Wall switch or wires defective.  
Check wall switch and wires for proper connections. Jumper  
wire across terminals at wall switch, if burner comes on,  
replace defective wall switch. If okay, jumper wires across  
wall switch wires at valve, if burner comes on, wires are  
faulty or connections are bad.  
B. Thermopile may not be generating  
Check thermopile with millivolt meter. Take reading at ther-  
mopile terminals of gas valve. Should read 325 millivolts  
minimum with optional wall switch OFF.Replace faulty  
thermopile if reading is below specified minimum.  
sufficient millivoltage.  
C. Plugged burner orifice.  
Check burner orifice for stoppage and remove.  
4. Frequent pilot/burner outage  
A. Pilot flame may be too low or  
blowing (high) causing the pilot/  
valve safety to drop out.  
Clean and/or adjust pilot flame for maximum flame impinge-  
ment on thermogenerator (Figure 8 on page 6 ).  
problem.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM  
Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in  
the ONposition.  
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.  
SYMPTOM  
POSSIBLE CAUSES  
A. Faulty Valve System.  
B. Faulty limit switch.  
CORRECTIVE ACTION  
1. Burner will not light.  
See Below.  
Resetthelimitswitchbutton.Ifstillnotworking,removewirenutfromtheleadsattached  
to the limit switch and check for continuity. If no continuity, replace limit switch.  
C. OFF/ONor wall switch Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with  
defective.  
a multimeter. If continuity is not indicated, switch(s) is defective and must be  
replaced.  
Note: Before replacing OFF/ONswitch, be sure to check wiring for loose connec-  
tions or broken wires and repair as needed.  
2. Burners come ONbut A. Burner orifice plugged. Check main burner orifice(s) for stoppage. Clean or replace.  
go OFF.”  
B. Obstructed vent system. Check vent system for obstructions.  
START  
CHECK  
• Line Voltage Power  
• Check For Proper Voltage At Control Harness  
(See Insert A). Voltage Should Be 24V  
Between Thermostat Or Pressure Switch  
• Turn Off Gas Supply  
NO  
• Assure Valve Switch Is In ON Position  
• Disconnect Control Harness  
• Set Thermostat To Call For Heat  
• Low Voltage Transformer  
• Limit Controller  
• Thermostat  
And 24V Common And 24V Hot.  
2
• Wiring  
YES  
• Plug Control Harness Into Valve. Wait For  
Internal Check Delay.  
• With Pilot Burner Cable Connected, Measure  
Voltage At Valve HSI Element Output. 24V  
Nominal. (See Insert B)  
NO  
NO  
• Igniter Warms Up And Glows Red.  
• Replace Valve.  
Insert A  
End View Of  
Control Harness  
Connector  
1
2
24 Volt Hot  
YES  
24 Volt  
Common  
1
YES  
• Replace Igniter/Flame Rod Assembly.  
YES  
24 Volt  
Switched  
NO  
NO  
• Check That Pilot Gas Is Flowing. Wait To  
Assure Plot Gas Tubing Is Purged. Recycle  
Call For Heat If Necessary.  
• Replace Valve.  
• Turn On Gas Supply. • Pilot Burner Lights.  
Check For Damaged Or Missing Terminals  
In Connector  
YES  
• Measure Voltage Between 24V Hot And 24V Common  
Leads To Valve Control. Must Measure At Least 19.5  
VAC With Igniter Powered (See Insert A). To Identify  
Proper Lead, This Check Must Be Done With The  
Valve Control Connected And Igniter Powered.  
NO  
• Check Transformer And  
Line Volt Supply.  
Insert B  
YES  
Igniter Terminals  
YES  
• Replace Pilot Assembly.  
• Check That Pilot Flame Makes Good Contact With  
Pilot Burner Flame Rod.  
NO  
• Check For Good Electrical Connection Through The  
Pilot Tubing.  
• Main Valve Opens And Main Burner Lights.  
YES  
• If Both Of The Above Are Good, Replace Igniter/Flame  
Rod Assembly.  
YES  
• Cycle Thermostat Off And Back On.  
• System Is Okay.  
Igniter Will Cycle Off And Back On Once During  
When Measured Voltage At Connections, Use  
Care To Assure Terminals Are Not Damaged.  
NO  
1
2
• Main Burner Lights.  
• Replace Valve.  
The 90 Second Ignition Trial. All Voltage  
Measurements Must Be Taken While The Igniter  
Is Powered.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS LIST  
Natural  
Propane  
No.  
DESCRIPTION  
Part No. Qty.  
Part No. Qty.  
Gas Fireplace Assembly  
Firescreen  
2
2
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
161116  
161116  
Rod, Screen  
Front Log  
498169  
498169  
LB-97316A  
LB-97317A  
75L1101  
LB-97307  
21L8201  
75L2301  
LB-97316A  
LB-97317A  
75L1101  
LB-97307  
75L1001  
75L2301  
Rear Log  
Burner  
Log Grate  
Burner Orifice  
Limit Switch  
GAS CONTROLS — MILLIVOLT  
Natural  
Propane  
Part No. Qty.  
No.  
DESCRIPTION  
Gas Valve - SIT  
Gas Valve - Honeywell  
Pilot Assembly (SIT)  
Pilot Generator  
Electrode And Cable  
Piezo Igniter  
Part No. Qty.  
*10.  
*11.  
12.  
H165801  
62L0501  
62L1201  
60J7901  
74L5801  
111061  
1
1
1
1
1
1
1
1
H165901  
62L0501  
62L1301  
60J7901  
74L5801  
111061  
1
1
1
1
1
1
1
1
13.  
14.  
**15.  
**16.  
17.  
Ignition Cable  
902164  
902164  
Pilot Tube  
74L5601  
74L5601  
*Appliances may be fitted at the factory with either a Honeywell or SIT Millivolt gas control valve.  
**For SIT gas valve equipped appliances only.  
GAS CONTROLS — ELECTRONIC  
Natural  
Propane  
No.  
20.  
21.  
22.  
23.  
DESCRIPTION  
Part No. Qty.  
Part No. Qty.  
Gas Valve - Honeywell  
Pilot Assembly - Honeywell  
Transformer  
62L1801  
62L1401  
42J3201  
87L54  
1
1
1
1
62L1901  
62L1501  
42J3201  
87L54  
1
1
1
1
Ignitor Assembly (Kit)  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS  
4
2
7
3
1
5
6
10  
8
11  
16  
15  
20  
21  
14  
13  
22  
12  
23  
17  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS  
Remote Control System (Standard)  
H0249  
RCL  
86L26  
86L27  
86L28  
12M01  
12M02  
36 ABF  
36 ABF-BB  
36 ABF-BS  
36BF  
Twin Pane Doors  
86L29  
36 TPA-BB  
Standard Remote Control System  
(Model RCL)  
Twin Pane Doors  
Bi-Fold Doors  
36BF-BB  
The Model RCL (Standard) Remote Control  
System, features a simplistic on/off control  
function for the fireplace. This model includes  
a hand-held transmitter, a remote receiver with  
wall-mount coverplate and all hardware re-  
quired to install the unit. The remote receiver  
can be wall or hearth mounted.  
Your fireplace can be fitted with beautiful twin  
pane doors. Model TPA doors are available for  
use with these fireplace. Model TPA doors are  
easily fitted to the fireplace opening. Model 36  
TPA-BB doors have a beautiful bright brass  
finish.  
Bi-Fold Doors  
Your fireplace can be fitted with beautiful bi-  
fold doors. Model ABF doors are available for  
use with these fireplace. Doors are easily fitted  
to the fireplace opening. Model 36 ABF doors  
come with standard black finish. Model 36  
ABF-BB doors have a beautiful bright brass  
finish. Model 36 ABF-BS doors have a brushed  
stainless finish.  
The transmitter has ON and OFF functions that  
are activated by pressing either button on the  
face of the transmitter. When a button on the  
transmitterispressed, asignallightilluminates  
briefly to verify that a signal has been sent.  
To ensure warranty and to prevent a potential  
fire hazard, do not use any other doors on  
these appliances.  
The Model RCL is designed to operate with all  
millivolt ignition systems, as well as electronic  
ignitionsystems. Itmaybeinstalledwithusefor  
either natural or propane gas appliances. The  
RCL offers ease of installation and allows you to  
executeon-offcommandstothefireplaceeffort-  
lessly with one simple motion.  
Decorative Volcanic Stone  
80L42  
FDVS  
The Model RCL comes complete with detailed  
operating instructions.  
Decorative Volcanic Stone  
The decorative volcanic stone, Model FDVS,  
can be used to enhance the look of your appli-  
ance. Spread the decorative volcanic stone  
evenly around the bottom of the firebox.  
27M30  
27M31  
36GEP  
36GEP-BB  
Glass Enclosure Panels  
Touch-Up Paint Kit  
81L30  
FTPK-B  
Your fireplace can be fitted with beautiful glass  
enclosure panels with a bi-fold "look" (non-  
operable doors once installed). Model 36GEP  
is finished in black trim; model 36GEP-BB is  
finished in polished brass trim.  
Touch-Up Paint Kit  
Repair of minor scratches and discoloration of  
the appliance black painted surfaces may be  
accomplished with the touch-up paint kit.  
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.  
Consult your local distributor for fireplace code information.  
Printed in U.S.A. © 2001 by Lennox Hearth Products  
LHP  
P/N 725,008M REV. F 05/2004  
1110 West Taft Avenue • Orange, CA 92865  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teac Stereo Receiver T R670AM User Manual
Technicolor Thomson Flat Panel Television 42PB120S4 User Manual
Technicolor Thomson MP3 Player PDP2222 User Manual
Topcom Telephone Allure 400 User Manual
TRENDnet Security Camera TVIP612P User Manual
Tripp Lite Marine Battery RV1012UL User Manual
Troy Bilt Chipper 070 User Manual
Vermont Casting Stove Encore NC 1450 User Manual
ViewSonic Projector VS13783 User Manual
Vizio Universal Remote M3D470KDE User Manual