| AF 75 - 300mm F/4 - 5.6 LD   MACRO 1:3.9   (Model 672D)   Thank you for purchasing this Tamron lens. Please   read this owner's manual carefully before using your   new lens. Proper care and maintenance of this lens   will result in years of enjoyable use.   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   DESCRIPTION OF PARTS   1.   2.   3.   4.   5.   6.   7.   8.   9.   Focusing ring   Focus distance scale   Focus distance index   Zooming ring   Zooming scale   Tripod socket   Tripod socket fixing screw   Zoom index   Lens mounting guide   10. AF/MF selector switch   11. Aperture / Zoom index   12. Aperture ring   13. Aperture scale   14. AE (minimum aperture) lock   15. Hood attaching index   16. Magnification scale   17. Depth-of-field scale   18. Infrared index   19. Macro selector switch   6~7 are for Model 175D only   9 is for Canon/Minolta only   10 is for Canon only   12~14 are for Nikon / Pentax only   17 is for Model 179D only   18 is for Model A10 / 179D only   19 is for Model 572D / 772D only   SPECIFICATIONS   672D   75-300mm   F/4-5.6   Focal Length   Maximum Aperture   Angle of View   33 - 8   Lens Construction (Groups/Element)   Minimum Focus Distance   Maximum Magnification Ratio   Filter Size   9/13   1.5m (4.9')   1:3.9 (at Macro 300mm)   62mm   Length   118.7mm (4.67")   76.6mm (3.02")   435g (15.3oz)   Diameter   Weight   Download from Www.Somanuals.com. All Manuals Search And Download.   * Length and maximum diameter indicate the values for the lens with the Nikon mount.   * Specifications and design are subject to change without notice.   MOUNTING/REMOVING THE LENS   Mounting   After removing the rear cap, place the lens in the camera mount aligning the lens mount   index line with that of the camera body (Canon/Minolta/Pentax). For Nikon models, align   the lens mount index line with the dot on the camera. Rotate the lens clockwise until it   click-locks (counter-clockwise in case of Nikon body). (For details, please refer to the instruc-   tion manual of your camera.)   Removal   Push in and hold the lens release button on the camera body while rotating the lens count-   er-clockwise (clockwise in case of Nikon body.)   FOCUSING   Automatic Focusing (for Nikon/Minolta/Pentax AF SLR)   When the camera is on the autofocus mode, the lens focuses automatically. During AF (Auto   Focus) operation, the focusing ring will rotate and its movement should not be hindered.   Automatic Focusing (for Canon-EOS AF SLR)   Set the AF/MF Switch on the lens to "AF" mode. Pressing the shutter release button of the   camera will activate the auto-focusing function of the camera. During AF operation, the   focusing ring will rotate and its movement should not be hindered.   Manual Focusing   When the lens is used on a Nikon/Minolta/Pentax AF camera, switch the camera to the man-   ual focus mode. When the lens is on a Canon EOS camera, set the lens AF/MF Switch to the   "MF" mode. Turn the focusing ring while looking through the viewfinder. The correct focus   position is determined when the picture in the viewfinder becomes sharpest. In manual-   focus photography, focusing should always be checked through the viewfinder even when   shooting at infinity.   * For further details, see the instruction manual of your camera.   ZOOMING   To set your lens to the desired image composition you desire, simply look through the   viewfinder and operate the zoom ring.   Download from Www.Somanuals.com. All Manuals Search And Download.   MACRO SWITCHOVER MECHANISM   The model 672D allows macro photography by operating the macro selector switch. The   maximum magnification ratio in the macro photography mode is 1:2 (f = 300 mm, 0.95m).   It is necessary that the zoom be aligned to 180-300 mm when switching the macro   selector switch from Normal to Macro. In addition, it is necessary that the focus ring be   aligned to 1.5 m to infinity to switch from Macro to Normal.   SWITCHING TO MACRO PHOTOGRAPHY   First, turn the zoom ring to align the zoom between 180 and 300mm. Next, slide the macro   selector switch from the Normal to the Macro position. The lens is now switched to the   macro photography mode.   When in the macro photography mode, the focus ring rotates continuously from   infinity to the minimum focus distance of 0.95m. The magnification ratio reaches a maxi-   mum when the focus distance is 0.95 m at 300 mm. The magnification ratio at this time is   1:2.   When in the macro photography mode, the zoom ring can only be rotated over the   range of 180mm and 300mm. Angle of view can only be adjusted over the range of 180mm   to 300mm when in the macro photography mode.   The macro selector switch cannot be operated unless the zoom ring is between   180mm and 300mm. Always make sure to align the zoom ring between 180mm and   300mm before operating the macro selector switch.   CANCELLATION OF MACRO PHOTOGRAPHY   First check that the focus ring is aligned to 1.5m or farther (1.5 - infinity). (Turn the focus   ring to 1.5m or farther when it is set to a distance closer than 1.5m). Next, slide the macro   selector switch from the Macro position to the Normal position. The macro photography   mode is now cancelled.   The focus ring can only be turned between infinity and 1.5m when the macro selector   switch is set to the Normal position (when macro photography is cancelled.) It cannot be   turned to a distance closer than 1.5m.   The macro selector switch cannot be operated unless the focus ring is set to a dis-   tance between 1.5m and infinity. Always make sure to set the focus ring between 1.5m and   infinity before operating the macro selector switch.   Download from Www.Somanuals.com. All Manuals Search And Download.   APERTURE CONTROL & AE SETTING   Canon / Minolta   Your camera controls the aperture depending on the shooting mode in use. Although the   aperture value varies in accordance with zooming, the camera itself reads out the change to   provide automatic compensation.   Nikon / Pentax   When shooting in programmed AE or shutter-priority AE mode, rotate the aperture ring to   the minimum position. For aperture-priority or manual mode, turn the aperture ring to the   desired setting. In case of F401/F50 series models, the aperture is set by the camera in   accordance with the given camera instructions.   LENS HOOD   A bayonet-type lens hood is provided as a standard accessory. Tamron recommends shoot-   ing with the hood attached whenever possible as the lens hood cuts out light, which is   harmful to image quality. However, please be aware of the precautions noted below when   your camera is equipped with a built-in flash. When the hood is not in use, it can be placed   on the front of the lens in reverse:   Attaching the Lens Hood Align the index mark on the hood with the corresponding   index mark on the lens. Push the hood onto the lens and then rotate it clockwise to secure.   When attaching the lens hood, hold the focusing and zoom control rings so that they are   not rotated unintentionally.   TRIPOD SOCKET (Ref. Figs. 9 & 10)   To change the camera from horizontal to vertical position or vice versa, loosen the   locking knob for the tripod-attaching base by rotating it counterclockwise, then rotate lens   and the camera about the longitudinal axis of the lens. Tighten the locking knob by rotating   it in clockwise direction until it stops. (Fig. 9)   To remove the tripod-attaching base, loosen the locking knob, pull it back slightly, and   then lift the knob to open the tripod base ring as illustrated in Fig. 10. When removing the   tripod-attaching base, hold the lens and the camera securely to prevent them from both   accidentally falling.   Download from Www.Somanuals.com. All Manuals Search And Download.   Fig. 9   Fig. 10   Altering camera between vertical & horizon- Detaching tripod-attaching base   tal positions 1. Loosen lock knob by rotating knob coun-   1. Loosen lock knob by rotating knob coun- terclockwise.   terclockwise.   2. Pull out lock knob slightly.   2. Turn camera and lens so as position align- 3. Turn attaching ring upward while holding   ment marks meet each other.   locking knob.   3. Tighten lock knob by rotating knob clock- * When detaching tripod-attaching base,   wise.   hold camera and lens securely, not to acci-   dentally drop your valuable equipment.   CHECKING DEPTH-OF-FIELD   When you set the focus of a particular subject, there is an area in front of you and   behind your subject that will also be in focus.   The depth-of-field table shows aperture values horizontally and ranges vertically. If,   for example, the aperture is F8 and the shooting range is 5m (Focal length 400mm), the   depth-of-field value is 4.96 (m)-5.04 (m) where F8 in the horizontal column and 5m in the   vertical column intersect. If your camera has a preview mechanism, the depth-of-field effect   can be confirmed in the viewfinder. For further details, see the instruction manual of your   camera.   PRECAUTIONS IN SHOOTING   When the built-in flash on the camera is used, symptoms such as corner illumination   fall-off or vignetting at the bottom part of the image may be observed, especially at the   wider-angle range. This is due to the inherent limitation of the coverage of the built-in flash,   and/or the relative position of the flash to the edge of the lens barrel, which causes shad-   ows on the image. Accordingly, we recommend not using the built-in flash at wider-angle   settings.   Please refer to the section of your camera's instruction manual pertaining to the use   of the built-in flash, since the angles of coverage of the flashes differ between camera mod-   els.   Download from Www.Somanuals.com. All Manuals Search And Download.   PRECAUTIONS IN SHOOTING (con’t)   When you use a built-in flash, make sure to detach the lens hood.   Certain camera models may indicate the maximum and minimum aperture values of   the lens in approximate numbers. This is inherent to the design of the camera and not an   indication of error.   Do not use the lens hood when you shoot with your camera's built-in flash. Even with-   out the lens hood, an arched-shape shadow may be observed at the bottom portion of the   picture when using the built-in flash. Tamron recommends using an optional flash unit (clip-   on grip type) when use of flash is necessary.   When using the lens in the telephoto focal range, it may be necessary to use a tripod   to avoid camera shake. Using high-speed film (ISO 400 or faster) with a fast shutter speed is   also helpful to reduce the effect of camera shake.   TO ENSURE LONG-TERM SATISFACTION   Avoid touching the glass element surface. Use a photographic lens cloth or blower   brush to remove dust from the lens element surface. When not using the lens, always place   a lens cap on it for protection.   Use a lens cleaning tissue or lint cloth with a drop of cleaning solution to remove fin-   gerprints or dirt on the glass lens surface with a rotary motion from the center to edge. Use   a silicon cloth to clean your lens barrel only.   Mildew is an enemy of your lens. Clean the lens after shooting near water or in any   humid place. If you find mildew on your lens, consult a repair shop or nearby photographic   store.   When using your equipment [camera(s) and lens(es)] in an environment where the   temperature changes from one extreme to the other, make sure to put your equipment   temporarily in a case or plastic bag for a length of time in order for the equipment to go   through a gradual temperature shift. This will reduce potential equipment troubles.   Download from Www.Somanuals.com. All Manuals Search And Download.   |